Halsey Taylor HOF_FR.D Le manuel du propriétaire

Taper
Le manuel du propriétaire

Ce manuel convient également à

HOF14A-FR-Q*1D HOF14A-FR-Q*3D
97902C (Rev. C - 3/05)PAGE 1
HALSEY TAYLOR OWNERS MANUAL
USES HFC-134A REFRIGERANT
FIG. 1
36
35
32, 33
35
11
6
21
31
7, 8, 9,
10, 40,
5
34 19
See Fig. 3
20
28
30
12
15, 16,
17, 18
2, 3, 42
4 See Fig. 4
13, 14
41
39
HOF14A-FR-Q*1D HOF14A-FR-Q*3D
PAGE 2
97902C (Rev. C - 3/05)
FIG. 2
E = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) (MÍN.) DE HOLGURA ENTRE LA
REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE
MUR.
F = POWER CORD 4' (1219mm) LONG
CABLE ELÉCTRICO DE 4' (1219mm) PIE, DE LARGO
CORDON D’ALIMENTATION 4' (1219mm)
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2 IN. (38 mm) OUT
FROM WALL SHUT OFF BY OTHERS
SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM. A FUERA DE
LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS.
EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 mm) D.E.
CONNECTANT UNE TUYAUTERIE DEPUIS LE ROBINET D'ARRÊT FOURNI PAR D'AUTRES.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼” DE DIÁMETRO.
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE D’EAU.
C = 1-1/4 TRAP NOT FURNISHED
PURGADOR DE 1¼ NO PROPORCIONADO
SIPHON 1-1/4 NON FOURNI
D = ELECTRICAL OUTLET LOCATION WITH GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
UBICACIÓN DE LA TOMA DE ELECTRICIDAD
EMPLACEMENT DE LA PRISE DE COURANT
HOF14A-FR-Q*1D HOF14A-FR-Q*3D
97902C (Rev. C - 3/05)PAGE 3
PUSH BUTTON VALVE ADJUSTMENT
FIG. 3
1, 37, 38
29
23
25
24
22,26,27
ADJUST THIS SCREW TO ELIMINATE
VALVE LEVER "FREE PLAY" OR
CONTINUOUS FLOW FROM BUBBLER
STREAM HEIGHT
ADJUSTMENT SCREW
FIG. 4
1
37
38
Wiring Diagram
HOF14A-FR-Q*1D HOF14A-FR-Q*3D
PAGE 4
97902C (Rev. C - 3/05)
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE WWW.HALSEYTAYLOR.COM
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.
ITEM NO.
PART NO. DESCRIPTION
45392C
600985451640
160270508640
28461C
66506C
31513C
35775C
35840C
35844C
35768C
45698C
66252C
101453431640
101507531550
31491C
30664C
70018C
402672043730
66203C
66581C
35901C
15005C
26860C
26861C
26862C
50986C
61314C
55996C
55880C
401536242830
401536342830
75588C
55913C
35906C
35907C
35910C
100322740560
15009C
101452831560
35843C
56092C
110868642550
401507442830
27113C
27112C
Bubbler
Drain Plug
Strainer Plate
Basin
Evaporator
Cold Control
Compressor Serv. Pak
Overload
Capacitor
Relay Cover
Tailpipe Assy
Condenser
Cap Push Button
Push Button Stem
Fan Motor
Fan Blade
Fan Blade Nut
Fan Motor Bracket
Drier
Heat Exchanger
Power Cord
Regulator Retaining Nut
Regulator Lever
Pivot Bracket
Regulator Retaining Bracket
Regulator Holder
Regulator
Strainer
Regulator Mounting Bracket
Side Panel - Right
Side Panel - Left
Nut - Slip Nut 1-1/4
Adaptor - Drain
Heater Strip
Switch-Heater
Heater Thermostat Assy
Washer
Bubbler Nipple Assy
Fan - Shroud
Relay
Poly Tubing (Cut To Length)
Screw - #10-24
Front Panel
Plumbing Box
Plumbing Box Cover
115V ITEMIZED PARTS LIST
1
2
3
4
5
6
*7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
NS
NS
NS
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE
WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water
coolers or orders for repair parts MUST include Model No. and
Serial No. of cooler, name and part number of replacement part.
WARNING!
This unit is frost resistant down to 0
°
F with no
wind. Prevailing winds can reduce the ability of
the heater element to prevent light freezing. If the
ambient air temperature will drop below 0
°
F, the
cooler needs to be drained of all water by blowing
out all water lines, evaporator (item 5), and the
drain trap. A heater strip is used to heat the unit
and will begin to cycle at 40
°
+/- 5
°
F. A check at
this temperature will ensure the heater is working
and the unit is resistant to light freezing.
ALSO, MAKE SURE THERE ARE NO PLASTIC OR
FLAMMABLE COMPONENTS DIRECTLY ABOVE
THE HEATER STRIP.
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
ITEM NO.
PART NO. DESCRIPTION
220V/240V ITEMIZED PARTS LIST
*7
8
9
15
20
34
40
35951C
35953C
35955C
31431C
66502C
35916C
35954C
Compressor Serv. Pak
Overload
Capacitor
Fan Motor
Heat Exchanger
Heater Strip
Relay
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4