Franke FFPD5380 Guide d'installation

Catégorie
Articles sanitaires
Taper
Guide d'installation
PROFESSIONAL
EN Installation manual Kitchen Faucet
ES Manual de instalación Grifo de cocina
FR Manuel d‘installation Robinet de cuisine
FF5300 FF5380 FFPD5300 FFPD5380 FFPD5400 FFPD5480
SEMI PRO
– 3 –
EN
TABLE OF CONTENTS
Overview 4
Contents in box 4
Technical data 5
Installation instructions 6
Cleaning and maintenance 10
Replacing the cartridge 10
General maintenance 10
Spare/replacement list 11
FF5300 Series 11
Spare/replacement list 12
FFPD5300 Series 12
Spare/replacement list 13
FFPD5400 Series 13
Limited lifetime warranty 14
– 4 –
EN
OVERVIEW
Contents in box
1
2
3
4
5
6
8
9
7
2
9
10
3
4
5
6
8
1
7
FFPD5300 Series
1 - Faucet Assembly
2 - Aerator Key
3 - Plastic Flange
4 - Rubber Washer
5 - Fixing Plate
6 - Fixing Nut
7 - Supply Hoses
8 - Diverter
9 - Spout Set Screw
10 - Hex Key
FF5300 Series
1 - Faucet Assembly
2 - Aerator Key
3 - Plastic Flange
4 - Rubber Washer
5 - Fixing Plate
6 - Fixing Nut
7 - Supply Hoses
8 - Weight
9 - Check Valve Holder
– 5 –
EN
3
4
5
6
8
1
Technical data
Operating data Value
Operating pressure (ideal) 60 PSI 4.1 bar 410 kPa
Operating pressure (max.)* 125 PSI 8.6 bar 860 kPa
Operating pressure (min.)* 20 PSI 1.4 bar 140 kPa
Water temperature (ideal) 140°F 60°C
Water temperature (max.) 158°F 70°C
Hole Size For Faucet 1 3/8 35mm
10
11
12
9
13
2
7
NOTE: Contact us immediately if you see
inconsistencies.
phone: (1- 800-626-5771)
website: www.franke.us/ks
email: ks-customerservice.us@franke.com
FFPD5400 Series
1 - Faucet Assembly
2 - Aerator Keys
3 - Plastic Flange
4 - Rubber Washer
5 - Fixing Plate
6 - Fixing Nut
7 - Supply hoses
8 - Check Valve Holders
9 - Filtered water supply fitting
10 - 3/8“ poly tubing
11 - Hex Key
12 - Spout Set Screw
13 - Shut off valve
Certifies this faucet complies with ASME A112.18.1 / CSA B125.1 & NSF 61, NSF 372
and AB1953. The faucet also complies with water usage requirements of the
California Energy Comission and the US Department of Energy.
– 6 –
EN
INSTALLATION INSTRUCTIONS
1. Remove all contents from the package
and check for completeness.
2. Turn off water supply.
3. Cut a mounting hole 1 3/8“ diameter
(35 mm) in the desired mounting surface
(if one isn’t available).
4. Insert the faucet into the hole, hoses
rst (fi g. 2A).
ATTENTION: O-ring should come
pre-assembled in the base of the
faucet escutcheon sitting between the
countertop and the faucet base.
DO NOT use putty or other sealant at
this location.
NOTES: Solid surface installation:
The countertop mounting surface needs
to be fl at and free of debris; otherwise the
faucet may not sit properly and could leak.
5. Install the mounting hardware to the
mounting shank of the Faucet Base (1)
underneath the mounting surface in the
following order: Plastic Flange (3), Rubber
Washer (4) and Fixing Plate (5) (fi g. 2A).
2A
6. Secure the faucet by tightening the
Fixing Nut (6) onto the mounting shank
of the Faucet Base (1) (fi g. 2A).
ATTENTION: For FF5300 Series
7. Connect Spray Supply Hose (7) to
Check Valve Holder (8) and Spray
Hose(9) (fi g. 2B).
2B
7
8. Attach the Weight (10) to the Spray
Hose (9) approximately 2” above the
bend in the bottom of the Spray Hose
( fi g . 2C).
2“
2C
10
9
8
9
1
3
4
5
6
– 7 –
EN
9. Connect the Flexible Supply
Hoses (13) to the water supply
in the home (fig. 2D).
2D
13
13
10. Remove Aerator (14) using the
Aerator Key (15) (fig. 2E).
2F
14
2E
14
15
12. Turn on water, flush the faucet and
Aerator (14) to remove any debris and
check for leaks (fig. 2F).
13. Reinstall the Aerator (14) and ensure
everything is functioning properly.
ATTENTION: For FFPD5300 Series
8. NOTE: Secondary spout is NOT
secured to allow for better transportation.
Align the secondary spout parallel to the
main spout as shown in image 3A.
3A
Take the set screw attached to the
warning card and insert it into the back
of the body under the spout, and tighten
it with the hex key also attached to the
warning card (fig. 3B).
3B
The secondary spout rotation is
approximately 100 degrees to prevent it
from hitting the main spout (fig. 3C).
100°
3C
9. Connect Stainless Steel Mixed
Water Supply Hose (8) to the top of the
Diverter (10) (fig. 3D).
7
8
10
9
3D
– 8 –
EN
10. Connect the Stainless Steel Faucet
Supply Hose (9) to the largest fitting on
the Diverter (10) (fig. 3D).
11. Connect the Gray Nylon Spray Supply
Hose (7) to the smallest fitting on the
Diverter (10) (fig. 3D).
12. Connect the Flexible Supply Hoses
(11) to the water supply in the home
(fig. 3E).
3E
11
11
13. Remove Spout Aerator (14) using the
Spout Aerator Key (15) (fig. 3F).
3F
14
14. Turn on water, flush the faucet and
Aerator (14) to remove any debris and
check for leaks (fig. 3G).
3G
15. Reinstall the Aerator (14) and ensure
everything is functioning properly.
ATTENTION: For FFPD5400 Series
8. NOTE: Secondary spout is NOT
secured to allow for better transportation.
Align the secondary spout parallel to the
main spout as shown in image 4A.
4A
Take the set screw attached to the
warning card and insert it into the back
of the body under the spout, and tighten
it with the hex key also attached to the
warning card (fig. 4B).
4B
The secondary spout rotation is
approximately 100 degrees to prevent it
from hitting the main spout (fig. 4C).
100°
4C
9. Connect the Drinking Water Fitting (10)
to the Drinking Water Supply Hose (11)
with a 17 mm wrench.
15
14
– 9 –
EN
10. Connect the 3/8” Poly Tubing (9) to
the Drinking Water Fitting (10) and cut the
Poly Tubing (9) to proper length to remove
any unnecessary loops or low spots as
shown in figure 5A. Save excess Poly
Tubing (9) for water filtration connection.
IMPORTANT: When using push fittings,
ensure the ends of the tubing are cut
square and free of burrs or damage within
1” of the end of the tube. DO NOT use
any forms of sealing compounds or tools
to remove the tubing or modify the fitting
in any way, as this can damage the fitting
and result in leaks. Proper installation
and removal of tubing with push fittings is
outlined in figure 5B. Damage in this area
can cause leaks.
5A
How to insert / Remove Tubing
In Push Fit Connections
1. Insert the tubing squarely. See fig. 5B-1.
2. Make sure to insert tubing completely.
See fig. 5B-2.
3. To remove, push in collet and pull out
tubing. See fig. 5B-3.
5B-1 5B-2
5b-3
5B
11. Connect the Check Valve Holders (12)
to the Hot and Cold Supply Hoses
(red/blue) from the faucet as illustrated in
figure 5C.
5C
12. Connect the 3/8” Poly Tubing (9) to
the exit of the Water Filter (15), which
is NOT included with the faucet, as
illustrated in figure 5D.
IMPORTANT: Franke strongly
recommends using only genuine Franke
water filtration products with this faucet.
The installation or function of the faucet
can’t be guaranteed if using other
filtration products.
13. Connect the Shut-off Valve (13)
to the Cold Water Supply in the home
(blue) and connect the other side to the
Cold Water Supply Hose (blue) from the
faucet as illustrated in figure 5D.
IMPORTANT: DO NOT over-tighten
threaded connections for the shut-off
valve (13). DO NOT exceed 25 In-lbs of
torque.
14. Take excess 3/8” Poly Tubing (14)
from Step 10 and connect one end to
the push fitting connection of the Shut-
off Valve(13). Take the other end and
connect it to the inlet of the Water
Filter (15). See figure 5D for overview.
12
11
10
9
– 10 –
EN
5D
15. Connect the Hot Water Supply Hose
(red) to the Hot water supply in the
home (red) as indicated in figure 5D.
16. Remove Spray Aerator (16) using
the Spray Aerator Key (17) and remove
Spout Aerator (18) using the Spout
Aerator Key(19) (fig. 5E).
17. Turn on water, flush the faucet and
both Aerators (16 and 18) to remove any
debris and check for leaks (fig. 5F).
18. Reinstall the Aerators (16 and 18)
in reverse and ensure everything is
functioning properly.
CLEANING AND MAINTENANCE
Replacing the cartridge
1. Shut off the water supply to the faucet.
2. Turn on the faucet briefly to relieve
any pressure inside the faucet.
3. Move the faucet handle to the
“OFF” position.
4. Remove the set screw from the handle
assembly (A) using a 2.5 mm hex key.
5. Pull handle assembly (A) from
faucet body.
6. Unscrew the cartridge cap (B) from
faucet body.
7. Unscrew the cartridge lock nut (C).
8. Lift ceramic disc cartridge (D) from
the body and replace it with a new one.
Ensure the two lugs on bottom of the
cartridge sit properly in the allocated
holes at the base of the body.
9. Re-assemble faucet in reverse order.
10. Test for leakage.
General maintenance
Clean aerator periodically for any buildup.
Do not use harsh detergents, solvents,
chemical agents or metallic sponges as
these can damage the surface finish.
Clean only with a soft sponge and
soapy water.
Do not store chemicals or cleaning
agents in the immediate vicinity of the
faucet and connection hoses. Chemical
vapors could cause damage.
13
14
15
9
5F
5E
16
17
18
19
16 18
– 11 –
EN
Spare/replacement list FF5300 Series
A
F5301* Handle Assy
B
F5302* Cartridge Cap
C
F5303 Cartridge Lock Nut
D
F5304 Cartridge
E
F5305 Spray Holder
F
F5306 Spray O-Ring
G
F5307 Spray Check Valve
H
F5308* Spray Head Assy
J
F5309 Spray Aerator and Key
K
F5310 Plastic Flange
L
F5311 Fixing Kit
M
F5312 Weight
N
F5313 Supply Hoses
P
F5314 Spray Supply Hose
Q
F5315 Check Valve
R
F5316 Check Valve Holder
P N
Q
R
E
F
G
J
H
L
K
M
A
D
C
B
*Must Specify Finish
– 12 –
EN
Spare/replacement list FFPD5300 Series
A
F5301* Handle Assy
B
F5317* Cartridge Cap
C
F5318* Cartridge Lock Nut
D
F5319 Cartridge
E
F5305 Spray Holder
F
F5306 Spray O-Ring
G
F5307 Spray Check Valve
H
F5332* Hand Spray Assy
J
F5320 Aerator and Key
K
F5321 Spout Bushing Kit
L
F5310 Plastic Flange
M
F5311 Fixing Kit
N
F3112 Diverter Valve
P
F5322 Check Valve Holder
Q
F5315 Check Valve
R
F5313 Supply Hose
S
F5323 Faucet Supply Hose
T
F5314 Spray Supply Hose
Q
P
N
M
L
H
F
G
E
K
J
R S T
A
D
C
B
*Must Specify Finish
– 13 –
EN
Spare/replacement list FFPD5400 Series
A
F5301* Handle Assy
B
F5317* Cartridge Cap
C
F5318 Cartridge Lock Nut
D
F5319 Cartridge
E
F5305 Spray Holder
F
F5306 Spray O-Ring
G
F5324 Hand Spray Check Valve
H
F5325 Hand Spray Aerator and Key
J
F5326* Hand Spray Assy (dual function)
K
F5321 Spout Bushing Kit
L
F5327 Drinking Water Cartridge Kit
M
F5328* Drinking Water Handle Assy
N
F5329 Drinking Water Handle Bushing Kit
P
F5330 Drinking Water Aerator and Key
Q
F5310 Plastic Flange
R
F5311 Fixing Kit
S
F5313 Supply Hose
T
F5322 Check Valve Holder (1 pc)
U
F5315 Check Valve
V
F5331 Drinking Water Fitting
W
10305 3/8“ Poly Tubing
X
10306 Stop Valve
Q
P
N
M
L
H
F
G
E
K
J
R
S
V
D
B
A
C
W
T
U
X
*Must Specify Finish
– 14 –
EN
LIMITED LIFETIME WARRANTY
Franke Kitchen Systems LLC extends
the following warranty to the original
purchaser of its faucets effective
January 1, 2003.
All faucets installed in a private
residence will carry a limited lifetime
warranty on all mechanical parts to be
free of manufacturing defects in material
and workmanship under normal usage.
All chrome finishes carry a limited
lifetime warranty; all other finishes are
warranted for five (5) years from the
original date of purchase.
Marine and Outdoor Installation: Franke
faucets are NOT warranted for Marine
and Outdoor installations.
This warranty applies only to the
original owner, providing the product
has been installed in accordance with
our installation instructions, used
as recommended and in a normal
residential application. In the event
of a warranty claim, the owner will be
required to provide proof of purchase
- save sales receipt. This warranty
covers all components which make
the product operational. Franke, at
its option, may repair or replace the
product or components necessary to
restore the product to good working
condition. Franke reserves the right
to inspect the installation prior to the
actual replacement of the product or
component part. This warranty does
not cover misuse or abuse, accidental
damages, scuffs or scratches, improper
installation, abnormal usage, negligence
or damage caused by improper
maintenance or cleaning. Normal wear
of parts is excluded from the warranty.
Damage caused by impurities or acts
beyond our control are not covered.
Any product or part which has been
repaired or altered in any manner
outside of Frankes factory, unless
previously authorized in writing by
Franke, will void warranty.
Any replacement excludes
transportation and any labor
re-installation costs. This warranty
does not allow recovery of incidental or
consequential damages such as loss of
use, delay, property damage or other
consequential damage, and Franke
accepts no liability for such damages.
The Franke warranty is limited to the
above conditions and to the warranty
period specified herein and is exclusive.
Franke DISCLAIMS all other warranties,
expressed or implied, including IMPLIED
WARRANTIES OF MERCHANTABILITY
AND/OR FITNESS FOR A PARTICULAR
PURPOSE. This warranty gives you
specific legal rights that may vary from
state to state.
Further information
For any further information about our
products, about the installation of them
or about the guarantee, please contact
our customer service department:
Franke Kitchen Systems
800 Aviation Parkway
Smyrna, TN 37167, USA
Phone: 800-626-5771
Email: ks-customerservice.us@franke.com
– 15 –
– 16 –
ES
ÍNDICE
Información general 17
Contenido de la caja 17
Datos técnicos 18
Instrucciones de instalación 19
Limpieza y mantenimiento 24
Sustitución del cartucho 24
Mantenimiento general 24
Lista de partes/refacciones 25
Serie FF5300 25
Lista de partes/refacciones 26
Serie FFPD5300 26
Lista de partes/refacciones 27
Serie FFPD5400 27
Garantía limitada de por vida 28
– 17 –
ES
INFORMACIÓN GENERAL
Contenido de la caja
1
2
3
4
5
6
8
9
7
3
4
5
6
8
1
7
2
9
10
Serie FFPD5300
1 - Conjunto de la llave
2 - Llave para el aireador
3 - Brida de plástico
4 - Rondana de hule
5 - Placa de fijacn
6 - Tuerca de fijacn
7 - Mangueras de suministro
8 - Válvula desviadora
9 - Tornillo de fijación al tubo
10 - Llave hexagonal
Serie FF5300
1 - Conjunto de la llave
2 - Llave para el aireador
3 - Brida de plástico
4 - Rondana de hule
5 - Placa de fijacn
6 - Tuerca de fijacn
7 - Mangueras de suministro
8 - Peso
9 - Soporte de válvula de
retención
– 18 –
ES
3
4
5
6
8
1
Datos técnicos
Datos de operación Valor
Presión de operación (ideal) 60 PSI 4,1 bar 410 kPa
Presión de operación (x.)* 125 PSI 8,6 bar 860 kPa
Presión de operación (mín.)* 20 PSI 1,4 bar 140 kPa
Temperatura del agua (ideal) 140 °F 60°C
Temperatura del agua (máx.) 158 °F 70 °C
Tamaño de la perforación para la llave 1 3/8 35 mm
10
11
12
9
13
2
7
NOTA: Póngase en contacto con nosotros
inmediatamente si detecta inconsistencias.
teléfono: (1- 800-626-5771)
internet: www.franke.us/ks
correo electrónico:
ks-customerservice.us@franke.com
Serie FFPD5400
1 - Conjunto de la llave
2 - Llaves para el aireador
3 - Brida de plástico
4 - Rondana de hule
5 - Placa de fijacn
6 - Tuerca de fijacn
7 - Mangueras de suministro
8 - Soportes de válvula de retención
9 - Conector para el suministro de
agua filtrada
10 - Manguera de polietileno de 3/8“
11 - Llave hexagonal
12 - Tornillo de fijación al tubo
13 - Válvula de control
Certifica que esta llave cumple con ASME A112.18.1 / CSA B125.1, NSF 61, NSF 372
y AB1953. La llave también cumple con los requisitos de uso del agua de la Comisión
de Energía de California y del Departamento de Energía de los EE.UU.
– 19 –
ES
INSTRUCCIONES DE INSTALACIÓN
1. Saque todo el contenido de la caja y
compruebe que esté completo.
2. Interrumpa el suministro de agua.
3. Realice una perforación de 1 3/8
de diámetro (35 mm) en la super cie
de montaje deseada (si no hay una
perforación disponible).
4. Inserte la llave en la perforación,
introduciendo primero las mangueras
( fi g . 2A).
ATENCIÓN: El empaque debe venir
preinstalado en la base del chapetón de
la llave, y debe quedar asentado entre la
cubierta y la base de la llave.
NO use masilla ni ningún otro sellador
en este lugar.
NOTAS: Instalación en una superfi cie
sólida: la super cie de montaje en la
cubierta debe ser plana y estar libre de
elementos extraños, de lo contrario,
la llave podría no quedar asentada
adecuadamente y tener fugas.
5. Instale los accesorios de montaje en el
vástago de montaje de la base de la
llave(1) por debajo de la super cie de
montaje en el siguiente orden: brida de
plástico (3), rondana de hule (4) y placa de
jación (5) (fi g. 2A).
2A
6. Asegure la llave colocando
y apretando con la mano la tuerca de
jación (6) en el vástago de montaje de
la base de la llave (1) (fi g. 2A).
ATENCIÓN: Para la serie FF5300
7. Conecte la manguera de suministro
de rocío (7) al soporte de la válvula de
retención (8) y la manguera de rocío (9)
(fi g. 2B).
2B
7
8. Conecte el peso (10) a la manguera
de rocío (9) aproximadamente 2" por
encima de la curva en la parte inferior
de la manguera de rocío (fi g. 2C).
2“
2C
10
9
8
9
1
3
4
5
6
– 20 –
ES
9. Conecte las mangueras de suministro
flexibles (13) al suministro de agua de la
casa (fig.2D).
2D
13
13
10. Retire el aireador (14) usando la llave
para el aireador (15) (fig.2E).
2F
14
2E
14
15
12. Abra la llave, deje correr el agua
para eliminar cualquier elemento
extraño de la llave y el aireador (14)
y compruebe que no haya fugas (fig. 2F).
13. Vuelva a instalar el aireador (14)
y asegúrese de que todo funcione
correctamente.
ATENCIÓN: Para la serie FFPD5300
8. NOTA: El tubo secundario
NOseencuentra fijo con la finalidad
de facilitar el transporte. Alinee
eltubo secundario, de manera
quequede paralelo altubo principal,
comosemuestra enlaimagen3A.
3A
Tome el tornillo de fijación que viene
en la tarjeta de advertencia e insértelo
en la parte posterior del cuerpo, por
debajo del tubo. Apriételo con la llave
hexagonal que viene también en la tarjeta
deadvertencia(fig. 3B).
3B
La rotación del tubo secundario
esdeaproximadamente 100° para evitar
que choque con el tubo principal (fig. 3C).
100°
3C
9. Conecte la manguera de suministro de
agua mezclada de acero inoxidable (8) a la
parte superior de la válvula desviadora (10)
(fig. 3D).
7
8
10
9
3D
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Franke FFPD5380 Guide d'installation

Catégorie
Articles sanitaires
Taper
Guide d'installation