Generac XP6500E 0059340 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
www.generac.com or 1-888-436-3722
Owner's Manual
XP Series Portable Generator
DEADLY EXHAUST FUMES! ONLY use OUTSIDE far away
from windows, doors and vents!
NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT
APPLICATIONS.
SAVE this Manual. Provide this manual to any operator of
the generator.
Introduction ............................................................. 1
Read this Manual Thoroughly ................................. 1
Safety Rules ........................................................... 1
Standards Index .............................................................3
General Information ................................................ 4
1.1 Unpacking ......................................................................4
1.1.1 Accessory Box (6.5, 8 & 10kW) ........................4
1.2 Assembly .......................................................................4
1.2.1 Assembling the Wheel Kit ..................................4
1.2.2 Battery Connection (if equipped) ........................4
Operation ................................................................ 5
2.1 Know the Generator .......................................................5
2.1.1 Cold Weather Operation/De-icer .........................8
2.2 Hour Meter - With Reset .................................................9
2.3 Connection Plugs ...........................................................9
2.3.1 250 VAC, 20 Amp Duplex Receptacle ................9
2.3.2 120/240 VAC, 30 Amp Receptacle .....................9
2.3.3 120/240 VAC, 50 Amp Receptacle (10kW) ......10
2.3.4 Ground Fault Sensing Module ..........................10
2.3.5 120 VAC, 30 Amp Receptacle ..........................10
2.4 Automatic Idle Control (if equipped)..............................11
2.5 Voltage Selector Switch (3.6 & 6.5kW only) .................11
2.6 How to Use the Generator ............................................11
2.6.1 System Ground ................................................11
2.6.2 Grounding the Generator ..................................12
2.6.3 Connecting Electrical Loads .............................12
2.7 Overload Prevention .....................................................12
2.8 Wattage Reference Guide .............................................12
2.9 Before Starting the Generator .......................................13
2.9.1 Adding Engine Oil ............................................13
2.9.2 Adding Gasoline ...............................................13
2.10 Starting the Engine (electric start only) .........................14
2.11 Starting Pull Start Engines ............................................14
2.12 Stopping the Engine .....................................................14
2.13 Low Oil Level Shutdown System ..................................15
2.14 Charging the Battery (if equipped) ................................15
Maintenance ......................................................... 15
3.1 Performing Scheduled Maintenance .............................15
3.2 Maintenance Schedule .................................................15
3.3 Product Specifications ..................................................16
3.3.1 Generator Specifications ..................................16
3.3.2 Engine Specifications .......................................16
3.3.3 Emissions Information .....................................16
3.4 General Recommendations ...........................................17
3.4.1 Generator Maintenance ....................................17
3.4.2 To Clean the Generator .....................................17
3.4.3 Engine Maintenance .........................................17
3.4.4 Checking Oil Level ...........................................17
3.4.5 Changing the Oil and Oil Filter ..........................17
3.4.6 Replacing the Spark Plug(s) .............................17
3.4.7 Battery Replacement (if equipped) ...................18
3.4.8 Air Filter Replacement ......................................18
3.4.9 Clean Spark Arrestor Screen ............................19
3.4.10 Adjusting Valve Clearance ................................19
3.5 General ........................................................................20
3.6 Long Term Storage .......................................................20
Troubleshooting .................................................... 21
4.1 Troubleshooting Guide ..................................................21
Manual del Usuario............................................... 23
Manuel de l'utilisateur .......................................... 47
(000004)
WARNING
California Proposition 65. Engine exhaust and some of
its constituents are known to the state of California to
cause cancer, birth defects, and other reproductive
harm.
(000005)
WARNING
California Proposition 65. This product contains or
emits chemicals known to the state of California to
cause cancer, birth defects, and other reproductive
harm.
Table of Contents
INTRODUCTION
Thank you for purchasing this model by Generac Power Systems,
Inc. This model is a compact, high performance, air-cooled,
engine driven generator designed to supply electrical power to
operate electrical loads where no utility power is available or in
place of utility due to a power outage.
READ THIS MANUAL THOROUGHLY
If any portion of this manual is not understood, contact the nearest
Authorized Dealer for starting, operating and servicing procedures.
The operator is responsible for proper and safe use of the
equipment. We strongly recommend that the operator read this
manual and thoroughly understand all instructions before using
the equipment. We also strongly recommend instructing other
users to properly start and operate the unit. This prepares them
if they need to operate the equipment in an emergency. Save
these instructions for future reference. If you loan this device
to someone, ALWAYS loan these instructions to the individual
as well.
The generator can operate safely, efficiently and reliably only if it
is properly located, operated and maintained. Before operating or
servicing the generator:
• Become familiar with and strictly adhere to all local, state and
national codes and regulations.
• Study all safety warnings in this manual and on the product
carefully.
• Become familiar with this manual and the unit before use.
The manufacturer cannot anticipate every possible circumstance
that might involve a hazard. The warnings in this manual, and on
tags and decals affixed to the unit are, therefore, not all inclusive.
If using a procedure, work method or operating technique that the
manufacturer does not specifically recommend, ensure that it is
safe for others. Also make sure the procedure, work method or
operating technique utilized does not render the generator unsafe.
THE INFORMATION CONTAINED HEREIN WAS BASED ON
MACHINES IN PRODUCTION AT THE TIME OF PUBLICATION.
GENERAC RESERVES THE RIGHT TO MODIFY THIS MANUAL AT
ANY TIME.
SAFETY RULES
Throughout this publication, and on tags and decals affixed to the
generator, DANGER, WARNING, CAUTION and NOTE blocks are
used to alert personnel to special instructions about a particular
operation that may be hazardous if performed incorrectly or
carelessly. Observe them carefully. Their definitions are as follows:
(000001)
DANGER
Indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
(000002)
WARNING
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
(000003)
CAUTION
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
NOTE: Notes contain additional information important to a
procedure and will be found within the regular text body of this
manual.
These safety warnings cannot eliminate the hazards that they
indicate. Common sense and strict compliance with the special
instructions while performing the action or service are essential to
preventing accidents.
Four commonly used safety symbols accompany the DANGER,
WARNING and CAUTION blocks. The type of information each
indicates is as follows:
This symbol points out important safety
information that, if not followed, could
endanger personal safety and/or property of
others.
This symbol points out potential explosion
hazard.
This symbol points out potential fire hazard.

This symbol points out potential electrical
shock hazard.
Introduction
1
GENERAL HAZARDS
• NEVER operate in an enclosed area, in a vehicle, or indoors
EVEN IF doors and windows are open.
• For safety reasons, the manufacturer recommends that the
maintenance of this equipment is carried out by an Authorized
Dealer. Inspect the generator regularly, and contact the nearest
Authorized Dealer for parts needing repair or replacement.
• Operate generator only on level surfaces and where it will not be
exposed to excessive moisture, dirt, dust or corrosive vapors.
(000111)
WARNING
Moving Parts. Keep clothing, hair, and appendages
away from moving parts. Failure to do so could
result in death or serious injury.
• Certain parts of the generator get extremely hot during
operation. Keep clear of the generator until it has cooled to
avoid severe burns.
• Do NOT operate generator in the rain.
• Do not alter the construction of the generator or change
controls which might create an unsafe operating condition.
(000116)
DANGER
Electrocution. Turn utility and emergency
power supplies to OFF before connecting power
source and load lines. Failure to do so will result
in death or serious injury.
• Do not insert objects through unit’s cooling slots.
• When working on this equipment, remain alert at all times.
Never work on the equipment when physically or mentally
fatigued.
• Lifting Warning Hazard: A falling generator can result in death,
bodily injury, and/or property damage. Stand clear of generator.
Lift is designed to carry only the weight of the generator. DO
NOT overload lifting bracket. Apply lifting strap or hook through
lift bar hole(s) only. DO NOT lift while generator is running.
• Never use the generator or any of its parts as a step. Stepping
on the unit can stress and break parts, and may result in
dangerous operating conditions from leaking exhaust gases,
fuel leakage, oil leakage, etc.
• On electric start models, disconnect the POSITIVE (+) battery
cable from the engine starter OR the NEGATIVE (-) battery
cable from the battery terminal, whichever is easier, before
transporting the generator.
NOTE: This generator is equipped with a spark arrestor muffler.
The spark arrestor must be maintained in effective working
order by the owner/ operator. In the State of California, a spark
arrestor is required by law (Section 4442 of the California
Public Resources Code). Other states may have similar laws.
Federal laws apply on federal lands.
EXHAUST & LOCATION HAZARDS
• Never operate in an enclosed area or indoors! NEVER use in
the home, in a vehicle, or in partly enclosed areas such as
garages, EVEN IF doors and windows are open! ONLY use
outdoors and far from open windows, doors, vents, and in an
area that will not accumulate deadly exhaust.
(000103)
DANGER
Asphyxiation. Running engines produce carbon
monoxide, a colorless, odorless, poisonous gas.
Carbon monoxide, if not avoided,
will result in death or serious injury.
• Adequate, unobstructed flow of cooling and ventilating air
is critical to correct generator operation. Do not alter the
installation or permit even partial blockage of ventilation
provisions, as this can seriously affect safe operation of the
generator. The generator MUST be operated outdoors.
• This exhaust system must be properly maintained. Do nothing
that might render the exhaust system unsafe or in noncompliance
with any local codes and/or standards.
• Always use a battery operated carbon monoxide alarm indoors,
installed according to the manufacturer's instructions.
• If you start to feel sick, dizzy, or weak after the generator has
been running, move to fresh air IMMEDIATELY. See a doctor, as
you could have carbon monoxide poisoning.
ELECTRICAL HAZARDS
• The generator produces dangerously high voltage when in
operation. Avoid contact with bare wires, terminals, connections,
etc., while the unit is running, even on equipment connected
to the generator. Ensure all appropriate covers, guards and
barriers are in place before operating the generator.
• Never handle any kind of electrical cord or device while
standing in water, while barefoot or while hands or feet are wet.
DANGEROUS ELECTRICAL SHOCK MAY RESULT.
• The National Electric Code (NEC) requires the frame and external
electrically conductive parts of the generator be properly
connected to an approved earth ground. Local electrical codes
may also require proper grounding of the generator. Consult
with a local electrician for grounding requirements in the area.
Safety Rules
2
• Use a ground fault circuit interrupter in any damp or highly
conductive area (such as metal decking or steel work).
• Do not use worn, bare, frayed or otherwise damaged electrical
cord sets with the generator.
• Before performing any maintenance on the generator, disconnect
the engine starting battery (if equipped) to prevent accidental
start up. Disconnect the cable from the battery post indicated
by a NEGATIVE, NEG or (–) first. Reconnect that cable last.
• In case of accident caused by electric shock, immediately shut
down the source of electrical power. If this is not possible,
attempt to free the victim from the live conductor. AVOID
DIRECT CONTACT WITH THE VICTIM. Use a non-conducting
implement, such as a rope or board, to free the victim from the
live conductor. If the victim is unconscious, apply first aid and
get immediate medical help.
FIRE HAZARDS
(000105)
DANGER
Explosion and Fire. Fuel and vapors are extremely
ammable and explosive. Add fuel in a well
ventilated area. Keep re and spark away. Failure to
do so will result in death or serious injury.
• Never add fuel while unit is running or hot. Allow engine to cool
completely before adding fuel.
• Never fill fuel tank indoors. Comply with all laws regulating
storage and handling of gasoline.
• Do not overfill the fuel tank. Always allow room for fuel
expansion. If tank is over-filled, fuel can overflow onto a hot
engine and cause FIRE or an EXPLOSION. Never store generator
with fuel in tank where gasoline vapors might reach an open
flame, spark or pilot light (as on a furnace, water heater or
clothes dryer). FIRE or EXPLOSION may result. Allow unit to
cool entirely before storage.
• Wipe up any fuel or oil spills immediately. Ensure that no
combustible materials are left on or near the generator. Keep
the area surrounding the generator clean and free from debris
and keep a clearance of five (5) feet (1.5 meters) on all sides to
allow for proper ventilation of the generator.
• Do not insert objects through unit cooling slots.
• NEVER operate the generator if connected electrical devices
overheat, if electrical output is lost, if engine or generator sparks
or if flames or smoke are observed while unit is running.
• Keep a fire extinguisher near the generator at all times.
• DO NOT operate in a hazardous location where there may be a
risk of expolsion of petrol fumes, leaking fuel or explosive dusts.
STANDARDS INDEX
1. National Fire Protection Association (NFPA) 70: The NATIONAL
ELECTRIC CODE (NEC) available from www.nfpa.org
2. National Fire Protection Association (NFPA) 5000: BUILDING
CONSTRUCTION AND SAFETY CODE available from www.
nfpa.org
3. International Building Code available from www.iccsafe.org
4. Agricultural Wiring Handbook available from www.rerc.org ,
Rural Electricity Resource Council P.O. Box 309 Wilmington,
OH 45177-0309
5. ASAE EP-364.2 Installation and Maintenance of Farm Standby
Electric Power available from www.asabe.org, American
Society of Agricultural & Biological Engineers 2950 Niles
Road, St. Joseph, MI 49085
This list is not all inclusive. Check with the Authority Having Local
Jurisdiction (AHJ) for any local codes or standards which may be
applicable to your jurisdiction.
MODEL NO:
SERIAL NO:
Unit ID Location
Safety Rules
3
4
1.1 UNPACKING
• Remove all packaging material.
• Remove separate accessory box.
• Remove carton off the generator.
1.1.1 ACCESSORY BOX
Check all contents (Figure 1). If any parts are missing or damaged
locate an authorized dealer at 1-888-436-3722.
Contents include:
• 2 Wheels*** Oil Funnel
• 2 Hair Pins*** 2 – Frame Feet***
• Spark Plug (Qty. 2 for 10kW) 12 Volt Adaptor Plug Charger***
• Air Filter Spark Plug Wrench
• Oil Filter Shop Towel
• 4 Hex Nuts 2 – Axle Brackets
• 2 5/8" Flat Washers (thin)* 2 5/8" Flat Washers (thick)*
• 4 Bolts x 45mm** 4 – Bolts x 50mm**
• 2 1 Quart SAE 30 Oil Bottles (Qty. 1 for XP4000)
* 6.5 and 8kW Only
** 10kW Only
*** All except 3.6kW
1.2 ASSEMBLY
Read entire Owner's Manual before attempting to assemble or
operate the generator. The generator requires some assembly
prior to using it. If problems arise when assembling the generator,
please call the Generator Helpline at 1-888-436-3722.
1.2.1 ASSEMBLING THE WHEEL KIT
The wheel kit is designed to greatly improve the portability of the
generator. A 10mm and a 13mm wrench are needed to install the
frame feet and axle bracket.
NOTE: The wheel kit is not intended for over-the-road use.
6.5, 8, and 10kW
Refer to Figure 1 and install the feet and wheels as follows:
1. Align the holes in the frame foot to the holes in the frame.
Secure foot with two hex nuts and the 45mm long bolts.
Repeat procedure for other foot.
2. Align the holes in the axle bracket to the holes in the frame.
Secure bracket with 50mm long bolts. Repeat procedure for
other bracket.
3. Slide the axle through the axle bracket holes.
4. Slide on one 5/8” flat washer (thick), the wheel, and a 5/8” flat
washer (thin) onto the axle.
5. Secure with hair pin and repeat for the other wheel.
Figure 1 – Wheel Assembly (6.5, 8 & 10kW)
BOLT X 45MM
LONG
FRAME FOOT
BOLT X 50MM
LONG
HEX NUT
AXLE
BRACKET
HAIR PIN
WHEEL
AXLE
5/8” FLAT WASHER
(THICK)
5/8” FLAT WASHER
(THIN)
1.2.2 BATTERY CONNECTION (IF EQUIPPED)
NOTE: The battery shipped with the generator has been fully
charged. A battery may lose some of its charge when not in use
for prolonged periods of time. If the battery is unable to crank
the engine, plug in the 12V charger included in the accessory
box (see the Charging a Battery section). RUNNING THE
GENERATOR WILL CHARGE THE BATTERY.
The unit has been deliberately shipped with the battery cables
disconnected. You will need two 8mm wrenches to secure the
battery cables.
See Figure 2 for connection details.
1. Cut off cable ties securing the battery cables.
2. First, connect the red battery cable and the red battery charger
wire to the positive (+) battery terminal. Use the supplied
screw and lock nut.
3. Connect the black battery cable and the black battery charger
wire to the negative (-) battery terminal. Use the supplied
screw and lock nut.
4. Make sure all connections are secure. Slide the rubber boots
over the terminals and connection hardware.
General Information
5
Figure 2 - Battery Connections
2.1 KNOW THE GENERATOR
Read the Owner’s Manual and Safety Rules before operating
this generator.
Compare the generator to Figures 3 through 7 to become
familiarized with the locations of various controls and adjustments.
Save this manual for future reference.
1. 120 Volt AC, 20 Amp, Duplex Receptacle Supplies electrical
power for the operation of 120 Volt AC, 20 Amp, single-phase,
60 Hz electrical lighting, appliance, tool and motor loads.
2. 120/240 Volt AC, 30 Amp Locking Receptacle Supplies
electrical power for the operation of 120 and/or 240 Volt AC,
30 Amp, single-phase, 60 Hz, electrical lighting, appliance,
tool and motor loads.
3. Circuit Breakers (AC) (6.5 & 8kW) Each receptacle is
provided with a push-to-reset circuit breaker to protect the
generator against electrical overload.
4. 2-Pole Circuit Breaker (6.5, 8 & 10kW) – this 30 Amp 2-pole
circuit breaker protects the 120/240 Volt locking receptacle.
NOTE: The 10kW uses both a 30 and 42 Amp 2-pole circuit
breaker.
5. 120 Volt AC, 30 Amp Locking Receptacle Supplies
electrical power for the operation of 120 Volt AC, 30 Amp,
single-phase, 60Hz electrical lighting, appliance, tool and
motor loads.
6. Idle Control with the switch in the “ON” position, the idle
control runs the engine at normal (high) speeds when there
is an electrical load present and runs the engine at idle (low)
speeds when a load is not present.
7. Fuse (6.5, 8 & 10kW) this 1.5 Amp fuse protects the
Battery Charger Input jack.
8. Ground Fault Sensing Module – supplies ground fault to
protect electrical power for all receptacles on the control
panel.
9. GFCI Circuit Breaker – Use to reset the full control panel GFCI
electrical system.
10. 10. Voltage Selector Switch (3.6 & 6.5kW only) - Allows the
user to choose between 120/240 volts, or 120 volt only. When
in the 120 volt only position, the total generator output is
available through any of the 120 volt outlets. In the 120/240V
position, receptacles of 120 and 240 volts AC can be used
simultaneously. The voltage selector switch provides the user
with more usable power and improved flexibility.
NOTE: NEVER switch the voltage selector switch with the main
breaker turned on! Doing this can cause arcing and can damage
the generator. First turn off all tools and appliances, turn off the
main circuit, and then operate the voltage selector switch.
11. Hour Meter Tracks hours of operation and alerts to service
intervals.
12. 120/240 Volt AC, 50 Amp Receptacle (10kW only) - Supplies
electrical power for the operation of 120/240 Volt AC, 42 Amp,
Single Phase, 60 Hz welder or motor loads.
13. Choke Knob Used when starting a cold engine.
14. Start Switch (6.5, 8, & 10kW) - Use to start engine from the
starter motor.
NOTE: The switch must be in the “On” position when starting
the engine from the recoil starter.
15. 3600 Watt On/Off Switch
16. Spark Plug(s) - See the Maintenance Schedule and Engine
Specification sections for details.
17. Oil Filter - See the Maintenance Schedule and Engine
Specification sections for details.
18. Summer/Winter Valve (10kW Engine ONLY) - Directs hot
engine air to the carburetor when the engine is running in cold
weather conditions. Move the valve to the left when operating
in temperatures above 40 ºF
(4.4 °C). When operating in
temperatures below 40 ºF (4.4 °C), move the summer/winter
valve to the right.
19. Oil Dipstick (10kW ONLY) - Check oil level in the engine.
Always make sure that the oil level is at the FULL mark before
starting engine.
20. Oil Drain Use to drain engine oil.
21. Oil Fill Add oil here.
22. Air Filter Filters intake air as it is drawn into the engine.
23. Recoil Starter (3.6, 6.5 & 8kW) - Use to start engine
manually.
24. MufflerQuiets the engine.
25. Spark Arrestor Reduces fire hazards by containing sparks.
26. Grounding Lug Ground the generator to an approved earth
ground here. See "Grounding the Generator" for details.
27. Handles Pivot and retract for storage. Press the spring-
loaded button to move handles.
28. Fuel Tank See generator Specifications for tank capacity.
29. Gas Cap Fuel fill location.
30. Fuel GaugeShows fuel level in tank.
31. Battery (6.5, 8 & 10kW) - Powers the electric starter motor.
32. Battery Charger Input (6.5, 8 & 10kW) - This receptacle
allows the capability to recharge the battery from the adaptor
plug charger.
33. Lifting Device use to lift and store the generator after use.
See Lifting Safety notes in the beginning of this manual.
Operation
6
Operation
000293
Figure 3 - 3,600 Watt Control Panel
15 11 1 8 9
34
6 5 3 2 10
2 1 5 10
000294
Figure 4 - 6,500 Watt Control Panel
14
13
34
32 7 4 6 3 11 8 9
7
Operation
000296
Figure 6 - 10,000 Watt Control Panel
000295
Figure 5 - 8,000 Watt Control Panel
14
13
34
2 15 11
32 7 46 3 8 9
11
32 1
4
5
12
7
34
3 35
9
8 2
6
8
34. Fuel Shut Off Valve between fuel tank and carburetor.
35. Fuse (10kW ONLY) - This 5 Amp fuse protects the starting
circuit from overload.
2.1.1 COLD WEATHER OPERATION/DE-ICER
Under certain weather conditions (temperatures below 40 °F (4.4
°C) and a high dew point), the engine may experience icing of the
carburetor and/or the crankcase breather system. To eliminate
this problem, this generator engine is fitted with a winter/summer
valve. This directs hot air into the carburetor during cold weather
operation. Always make sure the winter/summer valve is in the
correct location relative to the weather conditions (Figure 8).
Figure 8 – Winter/Summer Valve
Operation
220cc Engine for
3.6kW Model
410cc Engine for
6.5 & 8kW Models
530cc Engine for
10kW Model
Figure 7 - Generator Controls
9
2.2 HOUR METER - WITH RESET
The Hour Meter tracks hours of operation for scheduled
maintenance (see chart) (Figure 9).
Operation: Push and release the reset button (A) to toggle
between screens. The hours count backwards from the set interval
as shown in the chart.
When the meter reaches 5 hours,the text "CHG OIL" (or "SVC AIR
FILTER" or "CHG PLUG") will flash continually for two minutes.
After this time, the meter will go back to displaying the total hours
of the unit (for 2 minutes). This cyle will repeat for the entire 5
hours.
When the service interval reaches zero hours, the text "NOW"
replaces the hours remaining.
For a new generator for instance, the message will say "CHG OIL"
then flash "in 30". This means that in 30 hours, the oil will need to
be changed. Pressing the button a few more times will bring the
meter back to the screen that shows the total hours run.
Reset: Toggle to the alert that you wish to reset then hold the
button down for 9 seconds. The maintenance hours are reset when
the display shows "0000.0".
NOTE: The hour glass graphic (B) will flash on and off when
the engine is running. This signifies that the meter is tracking
hours of operation.
Figure 9 – Hour Meter
0000.0
2.3 CORD SETS AND CONNECTION PLUGS
2.3.1 120 VAC, 20 AMP, DUPLEX RECEPTACLE
This is a 120 Volt outlet protected against overload by a 20 Amp
push-to-reset circuit breaker (Figure 10). Use each socket to
power 120 Volt AC, single phase, 60 Hz electrical loads requiring
up to a combined 2400 watts (2.4 kW) or 20 Amps of current. Use
only high quality, well-insulated, 3-wire grounded cord sets rated
for 125 Volts at 20 Amps (or greater).
Keep extension cords as short as possible, preferably less than 15
feet (4.5 m) long, to prevent voltage drop and possible overheating
of wires.
Figure 10 - 120 Volt AC, 20 Amp, Duplex Receptacle
2.3.2 120/240 VAC, 30 AMP RECEPTACLE
Use a NEMA L14-30 plug with this receptacle (rotate to lock/
unlock). Connect a suitable 4-wire grounded cord set to the plug
and to the desired load. The cord set should be rated for 250 Volts
AC at 30 Amps (or greater) (Figure 11).
Operation
Hour Meter (With Reset) Chart
Message Frequency of Message Interval Duration of message
CHG OIL Initial break-in period First 30 Hours
ON/OFF for 2 minutes in a 5
hour period
CHG OIL Re-occuring 100 hours
SVC AIR FILTER Re-occuring 200 hours
CHG PLUG Re-occuring 200 hours
A
B
10
Figure 11 - 120/240 VAC, 30 Amp Receptacle
Use this receptacle to operate 120 Volt AC, 60 Hz, single phase
loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps or
240 Volt AC, 60 Hz, single phase loads requiring up to 7200 watts
(7.2 kW) of power at 30 Amps. The outlet is protected by a 2-pole
circuit breaker.
2.3.3 120/240 VAC, 50 AMP RECEPTACLE (10KW)
Use a NEMA 14-50 plug with this receptacle. Connect a 4-wire
cord set rated for 250 Volts AC at 50 Amps to the plug (Figure 12).
Use this receptacle to operate 120/240 Volt AC, 60 Hz electrical
loads requiring up to 10,000 watts (10.0 kW) of power at 41.6
Amps for 240 volts or two independent 120 Volt loads. This
receptacle is protected by a 42 Amp 2-pole circuit breaker.
Figure 12 - 120/240 VAC, 50 Amp Receptacle
50 A
NOTE: Receptacles may be marked with rating values greater
than generator output capacity.
2.3.4 GROUND FAULT SENSING MODULE
This unit is equipped with a ground fault circuit interrupter (GFCI).
This device meets applicable federal, state and local codes. The
ground fault sensing module covers all receptacles.
In the event of a ground fault, the GFCI will trip and quickly stop the
flow of electricity to prevent serious injury.
Definition: The GFCI constantly monitors electricity flowing in a
circuit. If the current flowing through the circuit varies from what
is returning by even a small amount, the GFCI instantly switches
power off by tripping the main circuit breaker on the generator's
control panel.
A GFCI does NOT protect against circuit overloads, short circuits,
or shocks. For example, electric shock can still occur if a person
touches charged electrical wires while standing on a non-
conducting surface, such as a wood floor.
Test the GFCI outlet before each use as follows (Figure 13):
1. Start the generator.
2. Plug a test lamp into duplex receptacle, the lamp should be on.
3. Press the “Test” button on the GFCI to trip the device. The main
breaker should ‘trip’, this being indicated by the movement of
the actuator handle to the ‘OFFposition.
4. This should stop the flow of electricity making the lamp shut
off. If the main breaker does not ‘trip’, the GFCI is not working
and the generator should not be used. Contact a local service
dealer.
5. To restore the flow of electricity, set the main breaker actuator
handle to the ‘ON’ position. The handles should remain
latched in this position. If it does not, either the GFCI or the
main breaker is failing and should be replaced. Contact a local
service dealer.
6. This GFCI is protected against overload by a 35A/240V main
breaker.
Figure 13 - Testing the GFCI
000361
2.3.5 120 VAC, 30 AMP RECEPTACLE
Use a NEMA L5-30 plug with this receptacle (rotate to lock/
unlock). Connect a suitable 3-wire cord set to the plug and to the
desired load. The cord set should be rated for 250 Volts AC at 30
Amps (or greater) (Figure 14).
Use this receptacle to operate 120 Volt AC, 60Hz, single phase
loads requiring up to 7200 watts (7.2kW) of power at 30 Amps.
The outlet is protected by a 30 Amp push-to-reset circuit breaker.
Operation
11
Operation
Figure 14 - 120 VAC, 30 Amp Receptacle
2.4 AUTOMATIC IDLE CONTROL (IF EQUIPPED)
This feature is designed to greatly improve fuel economy. When
this switch is turned On,” the engine will only run at its normal
fast governed engine speed when electrical load is connected.
When the load is removed, the engine will run at a reduced speed.
With the switch Off,” the engine runs at the normal fast engine
speed all the time. Always have the switch OFF when starting and
stopping the engine (Figure 13).
2.5 VOLTAGE SELECTOR SWITCH (3.6 & 6.5KW
ONLY)
Allows the user to choose between 120/240 volts, or 120 volt
only. When in the 120 volt only position, the total generator output
is available through any of the 120 volt outlets. In the 120/240V
position, receptacles of 120 and 240 volts AC can be used
simultaneously. The voltage selector switch provides the user with
more usable power and improved flexibility.
NOTE: NEVER switch the voltage selector switch with the main
breaker turned on! Doing this can cause arcing and can damage
the generator. First turn off all tools and appliances, turn off the
main circuit, and then operate the voltage selector switch.
2.6 HOW TO USE THE GENERATOR
If there are any problems operating the generator, please call the
generator helpline at 1-888-436-3722.
Never operate in an enclosed area or indoors! NEVER
use in the home, in a vehicle, or in partly enclosed areas
such as garages, even if doors and windows are open!
ONLY use outdoors and far from open windows, doors,
vents, and in an area that will not accumulate deadly
exhaust.
(000103)
DANGER
Asphyxiation. Running engines produce carbon
monoxide, a colorless, odorless, poisonous gas.
Carbon monoxide, if not avoided,
will result in death or serious injury.
Adequate, unobstructed flow of cooling and ventilating
air is critical to correct generator operation. Do not
alter the installation or permit even partial blockage of
ventilation provisions, as this can seriously affect safe
operation of the generator. The generator MUST be
operated outdoors.
This exhaust system must be properly maintained. Do
nothing that might render the exhaust system unsafe or
in noncompliance with any local codes and/or standards.
Always use a battery operated carbon monoxide alarm
indoors, installed according to the manufacturer's
instructions.
2.6.1 SYSTEM GROUND
The generator has a system ground that connects the generator
frame components to the ground terminals on the AC output
receptacles.
NOTE: This generator system ground IS bonded to the neutral in
the generator (see applicable unit wiring diagram).
Special Requirements
There may be Federal or State Occupational Safety and Health
Administration (OSHA) regulations, local codes, or ordinances
that apply to the intended use of the generator. Please consult a
qualified electrician, electrical inspector, or the local agency having
jurisdiction:
• In some areas, generators are required to be registered with
local utility companies.
• If the generator is used at a construction site, there may be
additional regulations which must be observed.
12
Operation
Connecting to a Building’s Electrical System through a
Transfer Switch
IMPORTANT: Connections for standby power to a building’s
electrical system must be made by a qualified electrician. The
connection must isolate the generator power from utility power, or
other alternative power sources, and must comply with all related
laws and codes.
NOTE: This generator system ground IS bonded to the neutral in
the generator (see applicable unit wiring diagram).
2.6.2 GROUNDING THE GENERATOR
Local electrical codes may require proper grounding of the unit. For
that purpose, connecting a No. 10 AWG (American Wire Gauge)
stranded copper wire to the grounding lug and to an earth-driven
copper or brass grounding rod (electrode) provides adequate
protection against electrical shock. However, local codes may vary
widely. Consult with a local electrician for grounding requirements
in the area. Proper grounding of the generator will help prevent
electrical shock in the event of a ground fault condition in the
generator or in connected electrical devices. Proper grounding
also helps dissipate static electricity, which often builds up in
ungrounded devices.
Figure 15 - Grounding the Generator
2.6.3 CONNECTING ELECTRICAL LOADS
DO NOT connect 240 Volt loads to 120 Volt receptacles. DO NOT
connect 3-phase loads to the generator. DO NOT connect 50 Hz
loads to the generator.
• Let engine stabilize and warm up for a few minutes after
starting.
• Plug in and turn on the desired 120 or 240 Volt AC, single
phase, 60 Hz electrical loads.
• Add up the rated watts (or amps) of all loads to be connected
at one time. This total should not be greater than (a) the rated
wattage/amperage capacity of the generator or (b) circuit
breaker rating of the receptacle supplying the power. See "Don't
Overload the Generator".
2.7 OVERLOAD PREVENTION
Overloading a generator in excess of its rated wattage capacity
can result in damage to the generator and to connected electrical
devices. Observe the following to prevent overloading the unit:
• Add up the total wattage of all electrical devices to be connected
at one time. This total should NOT be greater than the
generator's wattage capacity.
• The rated wattage of lights can be taken from light bulbs. The
rated wattage of tools, appliances and motors can usually be
found on a data label or decal affixed to the device.
• If the appliance, tool or motor does not give wattage, multiply
volts times ampere rating to determine watts (volts x amps =
watts).
• Some electric motors, such as induction types, require about
three times more watts of power for starting than for running.
This surge of power lasts only a few seconds when starting
such motors. Make sure to allow for high starting wattage when
selecting electrical devices to connect to the generator:
1. Figure the watts needed to start the largest motor.
2. Add to that figure the running watts of all other connected
loads.
The Wattage Reference Guide is provided to assist in determining
how many items the generator can operate at one time.
NOTE: All figures are approximate. See data label on appliance
for wattage requirements.
2.8 WATTAGE REFERENCE GUIDE
Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Running Watts
*Air Conditioner (12,000 Btu). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1700
*Air Conditioner (24,000 Btu). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3800
*Air Conditioner (40,000 Btu). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6000
Battery Charger (20 Amp). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
Belt Sander (3") . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
Chain Saw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Circular Saw (6-1/2") . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .800 to 1000
*Clothes Dryer (Electric) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5750
*Clothes Dryer (Gas) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
*Clothes Washer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1150
Coffee Maker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1750
*Compressor (1 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000
*Compressor (3/4 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1800
*Compressor (1/2 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1400
Curling Iron. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
*Dehumidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 650
Disc Sander (9"). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Edge Trimmer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
Electric Blanket. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
Electric Nail Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Electric Range (per element). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500
Electric Skillet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1250
*Freezer . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..700
*Furnace Fan (3/5 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 875
*Garage Door Opener . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .500 to 750
Hair Dryer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Hand Drill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 to 1100
Hedge Trimmer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450
Impact Wrench. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
13
Iron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
*Jet Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800
Lawn Mower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Light Bulb. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Microwave Oven. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .700 to 1000
*Milk Cooler. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1100
Oil Burner on Furnace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
Oil Fired Space Heater (140,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . 400
Oil Fired Space Heater (85,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . . 225
Oil Fired Space Heater (30,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . . 150
*Paint Sprayer, Airless (1/3 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600
Paint Sprayer, Airless (handheld). . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Radio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 to 200
*Refrigerator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
Slow Cooker. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
*Submersible Pump (1-1/2 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . 2800
*Submersible Pump (1 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000
*Submersible Pump (1/2 HP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500
*Sump Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .800 to 1050
*Table Saw (10") . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1750 to 2000
Television . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200 to 500
Toaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000 to 1650
Weed Trimmer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
* Allow 3 times the listed watts for starting these devices.
2.9 BEFORE STARTING THE GENERATOR
Prior to operating the generator, engine oil and gasoline will need
to be added, as follows:
2.9.1 ADDING ENGINE OIL
All oil should meet minimum American Petroleum Institute (API)
Service Class SJ, SL or better. Use no special additives. Select
the oil's viscosity grade according to the expected operating
temperature (also see chart).
• Above 40 °F
(4.4 °C), use SAE 30
• Below 40 °F
(4.4 °C) and down to 10 °F (-12 °C), use 10W-30
• Below 10 °F (-12 °C), use synthetic 5W-30
10W-30
SAE 30
Synthetic 5W-30
Any attempt to crank or start the engine before it has
been properly serviced with the recommended oil may
result in an engine failure.
3.6 - 8kW Portables
1. Place generator on a level surface (not to exceed 15° in any
direction).
2. Clean area around oil fill and remove oil fill cap.
3. Slowly fill engine with oil through the oil fill opening until it
reaches the full mark. Stop filling occasionally to check oil
level. The engine is full when the oil level reaches the bottom
threads of the mating oil fill cap.
4. Install the oil fill cap and finger tighten securely.
5. Check engine oil level before starting each time thereafter.
10kW Portables
1. Place generator on a level surface (not to exceed 15° in any
direction).
2. Clean area around oil fill and remove oil dipstick
3. Slowly fill engine with oil through the oil dipstick tube. Stop
filling occasionally to check oil level. The engine is full when
the oil reaches the full mark on the dipstick.
4. Install the oil dipstick.
5. Check engine oil level before starting each time thereafter.
2.9.2 ADDING GASOLINE
Use care when fueling the generator. Only fill the fuel tank when the
generator has cooled entirely. Use fresh unleaded gasoline with a
minimum Research Octane Number (RON) of 87.
NOTE: Do not use any gasoline containing more than 10%
Ethanol. NEVER fill the fuel tank with E85 or a mixture of oil and
gasoline designated for two-cycle engines.
(000105)
DANGER
Explosion and Fire. Fuel and vapors are extremely
ammable and explosive. Add fuel in a well
ventilated area. Keep re and spark away. Failure to
do so will result in death or serious injury.
Use regular UNLEADED gasoline with the generator engine. Do not
use premium gasoline. Do not mix oil with gasoline.
1. Clean area around fuel fill cap, remove cap.
2. Slowly add unleaded regular gasoline to fuel tank. Do not fill
above inner lip. Be careful not to overfill (Figure 16).
3. Install fuel cap and wipe up any spilled gasoline.
IMPORTANT: It is important to prevent gum deposits from forming
in fuel system parts such as the carburetor, fuel hose or tank
during storage. Alcohol-blended fuels (called gasohol, ethanol
or methanol) can attract moisture, which leads to separation and
formation of acids during storage. Acidic gas can damage the fuel
system of an engine while in storage. To avoid engine problems,
the fuel system should be emptied before storage of 30 days or
longer. See the "Storage" section. Never use engine or carburetor
cleaner products in the fuel tank as permanent damage may occur.
Operation
14
Figure 16 - Fuel Tank
DO NOT Fill Above Lip
Fuel
Fuel Tank
2.10 STARTING THE ENGINE (ELECTRIC START
ONLY)

Never start or stop engine with electrical devices
plugged into the receptacles AND devices turned on.
1. Unplug all electrical loads from the unit's receptacles before
starting the engine.
2. Make sure the unit is in a level position (not to exceed 15° in
any direction).
3. Locate the Idle Control ON/OFF switch on the control panel
and set it to the “OFFposition (Figure 17).
4. Open the fuel shut-off valve (Figure 18 (A)).
Figure 17 - Idle Control Switch
5. Pull the CHOKE knob outward to “Full Choke” position (Figure
18 (B)).
6. To start engine, press and hold the Start/Run/Stop switch in
the “Start” position. The engine will crank and attempt to start.
When the engine starts, release the switch to the run position.
7. When the engine starts, push choke knob in to “1/2 Choke”
position until the engine runs smoothly and then fully in to the
“Run” position. If engine falters, pull the choke knob back out
to “1/2 Choke” position until the engine runs smoothly and
then to “Run” position.
8. The 3.6 - 8kW portables are also equipped with a manual
recoil starter which may be used if the battery is discharged.
IMPORTANT: Do not overload the generator. Also, do not overload
individual panel receptacles. These outlets are protected against
overload with push-to-reset and 2-pole type circuit breakers. If
amperage rating of any circuit breaker is exceeded, that breaker
opens and electrical output to that receptacle is lost. Read “Don’t
Overload the Generatorcarefully.
2.11 STARTING PULL START ENGINES

Never start or stop engine with electrical devices
plugged into the receptacles AND devices turned on.
1. Unplug all electrical loads from the unit's receptacles before
starting the engine.
2. Make sure the unit is in a level position (not to exceed 15° in
any direction).
3. OPEN the fuel shut-off valve (Figure 18 (A)).
4. Turn the OFF/ON/START switch to the "ON" position (6.5,
8Kw).
5. Pull the choke knob outward (Figure 18 (B)); or the ON/OFF
switch to the "ON" position (3.6kW).
Figure 18 - Fuel Shut-off Valve
000297
6. To start engine, firmly grasp the recoil handle and pull slowly
until increased resistance is felt. Pull rapidly up and away.
7. When engine starts, move the choke knob to the 1/2-CHOKE
position until engine runs smoothly and then fully to the RUN
position. If engine falters, move choke back out to 1/2-CHOKE
until engine runs smoothly and then to RUN.
NOTE: If engine fires, but does not continue to run, move choke
to FULL CHOKE and repeat starting instructions.
IMPORTANT: Do not overload the generator. Also, do not overload
individual panel receptacles. These outlets are protected against
overload with push-to-reset and 2-pole type circuit breakers. If
amperage rating of any circuit breaker is exceeded, that breaker
opens and electrical output to that receptacle is lost. Read “Don’t
Overload the Generatorcarefully.
2.12 STOPPING THE ENGINE
1. Shut off all loads, then unplug the electrical loads from
generator panel receptacles. Never start or stop the engine
with electrical devices plugged in and turned on.
2. Let engine run at no-load for several minutes to stabilize the
internal temperatures of engine and generator.
3. Move START/RUN/STOP switch to the "OFF" position (6.5, 8
or 10kW); or the ON/OFF switch to the "OFF" position (3.6kW).
4. Close fuel valve.
Operation
B
A
15
2.13 LOW OIL LEVEL SHUTDOWN SYSTEM
The engine is equipped with a low oil level sensor that shuts down
the engine automatically when the oil level drops below a specified
level. If the engine shuts down by itself and the fuel tank has
enough gasoline, check engine oil level.
If the system senses a low oil level during operation, the engine
shuts down. The engine will not run until the oil has been refilled
to the proper level.
2.14 CHARGING THE BATTERY (IF EQUIPPED)

Storage batteries give off explosive hydrogen gas while
recharging. An explosive mixture will remain around the
battery for a long time after it has been charged. The
slightest spark can ignite the hydrogen and cause an
explosion. Such an explosion can shatter the battery and
cause blindness or other serious injury.
Never permit smoking, open flame, sparks or any
other source of heat around a battery. Wear protective
goggles, rubber apron and rubber gloves when working
around a battery. Battery electrolyte fluid is an extremely
corrosive sulfuric acid solution that can cause severe
burns. If spill occurs flush area with clear water
immediately.
NOTE: The battery shipped with the generator has been fully
charged. A battery may lose some of its charge when not in
use for prolonged periods of time. If the battery is unable
to crank the engine, plug in the 12V charger included in the
accessory box (see section "Charging the Battery"). RUNNING
THE GENERATOR WILL CHARGE THE BATTERY.
Use battery charger plug to keep the battery charged and ready for
use. Battery charging should be done in a dry location.
1. Plug charger into “Battery Charger Input” jack, located on the
control panel. Plug wall receptacle end of the battery charger
into a 120 Volt AC wall outlet (Figure 19).
2. Unplug battery charger from wall outlet and control panel jack
when generator is going to be in use.
NOTE: Do not use the battery charger for more than 48 hours
at one charge. If the battery is completely discharged, start the
unit per the "Starting Pull Start Engines" section and recharge
the battery by running the unit.
Figure 19 - Battery Charger Jack
BATTERY
CHARGER
INPUT
3.1 PERFORMING SCHEDULED MAINTENANCE
It is important to perform service as specified in the Maintenance
Schedule for proper generator operation, and to ensure that the
generator complies with the applicable emission standards for the
duration of its useful life. Service and repairs may be performed by
any capable person or repair shop. Additionally, emissions critical
maintenance must be performed as scheduled in order for the
Emissions Warranty to be valid. Emissions critical maintenance
consists of servicing the air filter and spark plugs in accordance
with the Maintenance Schedule.
3.2 MAINTENANCE SCHEDULE
Follow the calendar intervals. More frequent service is required
when operating in adverse conditions noted below.
Check Oil Level At Each Use
Change Oil and Oil Filter‡ *Every 100 hours or Every Season
Check Valve Clearance ***Every Season
Service Air Filter ** Every 200 hours or Every Season
Replace Spark Plug Every 200 hours or Every Season
Clean Spark Arrestor Screen Every 100 hours or Every Season
Change oil after first 30 hours of operation then every season.
* Change oil and oil filter every month when operating under heavy load or in high
temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air filter
parts if they cannot be adequately cleaned.
*** Check valve clearance and adjust if necessary after first 50 hours of
operation and every 100 hours thereafter.
15
Maintenance
16
3.3 PRODUCT SPECIFICATIONS
3.3.1 GENERATOR SPECIFICATIONS
3.6kW
Rated Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6kW
Surge Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5kW
Rated AC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120/240
Rated Max AC Load
Current @ 240V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Amps**
Current @120V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Amps**
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . .60 Hz @3600 RPM
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Phase
6.5 kW
Rated Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5kW**
Surge Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.13kW**
Rated AC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120/240
Rated Max AC Load
Current @ 240V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27.1 Amps**
Current @120V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54.2 Amps**
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . .60 Hz @3600 RPM
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Phase
8.0 kW
Rated Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.0kW**
Surge Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10kW**
Rated AC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120/240
Rated Max AC Load
Current @ 240V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33.3 Amps**
Current @120V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66.7 Amps**
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . .60 Hz @3600 RPM
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Phase
10.0 kW
Rated Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10kW**
Surge Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12kW**
Rated AC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120/240
Rated Max AC Load
Current @ 240V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41.7 Amps**
Current @120V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83.3 Amps**
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . .60 Hz @3600 RPM
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Phase
** Maximum wattage and current are subject to, and limited by, such factors
as fuel Btu content, ambient temperature, altitude, engine condition, etc..
Maximum power decreases about 3.5% for each 1,000 feet above sea level;
and will also decrease about 1% for each -12 °C (10° F) above 15.5 °C (60 °F)
ambient temperature.
3.3.2 ENGINE SPECIFICATIONS
3.6kW
Displacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216.5cc
Spark Plug Type. . . . . . . . . . . . . . . . . . Champion RC14YC or Equivalent
Spark Plug Part Number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0E7585
Spark Plug Gap . . . . . . . . . . . . . . . . . . . . . . . . . . .0.030 inch (0.76mm)
Gasoline Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 U.S. Gallons
Oil Type . . . . . . . . . . . . . . . . . . See Chart in “Adding Engine Oil” Section
Oil Capacity . . . . . . . . . . . . . . . . . . . w/Filter Change = 0.8 Qts (0.75 L)
w/out Filter Change = 0.5 Qts (0.47 L)
Oil Filter Part Number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 070185B
Run Time (50% Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.5 hours
Class I Emission Certified
6.5 & 8.0 kW
Displacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407cc
Spark Plug Type. . . . . . . . . . . . . . . . . . Champion RC14YC or Equivalent
Spark Plug Part Number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0E7585
Spark Plug Gap . . . . . . . . . . . . . . . . . . . . . . . . . . .0.030 inch (0.76mm)
Gasoline Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 U.S. Gallons
Oil Type . . . . . . . . . . . . . . . . . . See Chart in “Adding Engine Oil” Section
Oil Capacity . . . . . . . . . . . . . . . . . . . . w/Filter Change = 1.5 Qts (1.4 L)
w/out Filter Change = 1.2 Qts (1.0 L)
Oil Filter Part Number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 070185B
Run Time (50% Load . . . . . . . . . . . . .11 hours (6.5kW), 10 hours (8kW)
Class II Emission Certified
10.0 kW
Displacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 530cc
Spark Plug Type. . . . . . . . . . . . . . . . . . . . . . NGK BPR6HS or Equivalent
Spark Plug Part Number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0E9368
Spark Plug Gap . . . . . . . . . . . . . . . . . . . . . . . . . . .0.030 inch (0.76mm)
Gasoline Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.25 U.S. Gallons
Oil Type . . . . . . . . . . . . . . . . . . See Chart in “Adding Engine Oil” Section
Oil Capacity . . . . . . . . . . . . . . . . . . . . w/Filter Change = 1.8 Qts (1.7 L)
w/out Filter Change = 1.5 Qts (1.4 L)
Oil Filter Part Number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 070185B
Run Time (50% Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 hours
Class II Emission Certified
3.3.3 EMISSIONS INFORMATION
The Environmental Protection Agency (and California Air Resource
Board for generators certified to CA standards) require(s) that
this generator comply with exhaust and evaporative emission
standards. Locate the emissions compliance decal on the engine
to determine what standards the generator meets. This generator
is certified to operate on gasoline. The emission control system
consists of the following:
• Air Induction System
Intake Pipe / Manifold
Air Cleaner
• Fuel System
Carburetor
Fuel Tank / Cap
Fuel Lines
Evaporative Vent Lines
Carbon Canister (for CA engines only)
• Ignition System
Spark Plug
Ignition Module
• Exhaust System
Exhaust Manifold
Muffler
Catalyst (for CA engines only).
16
Maintenance
17
3.4 GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that have been
subjected to operator abuse or negligence. To receive full value
from the warranty, the operator must maintain the generator as
instructed in this manual.
Some adjustments will need to be made periodically to properly
maintain the generator.
All adjustments in the Maintenance section of this manual should
be made at least once each season. Follow the requirements in the
"Maintenance Schedule".
NOTE: Once a year replace the spark plug(s) and replace the
air filter. A new spark plug(s) and a clean air filter assure proper
fuel-air mixture, and help the engine run better and last longer.
3.4.1 GENERATOR MAINTENANCE
Generator maintenance consists of keeping the unit clean and dry.
Operate and store the unit in a clean dry environment where it will
not be exposed to excessive dust, dirt, moisture or any corrosive
vapors. Cooling air slots in the generator must not become clogged
with snow, leaves, or any other foreign material.
Check the cleanliness of the generator frequently and clean when
dust, dirt, oil, moisture or other foreign substances are visible on
its exterior surface.
Never insert any object or tool through the air cooling
slots, even if the engine is not running.
NOTE: DO NOT use a garden hose to clean generator. Water
can enter the engine fuel system and cause problems. In
addition, if water enters the generator through cooling air
slots, some water will be retained in voids and crevices of the
rotor and stator winding insulation. Water and dirt buildup on
the generator internal windings will eventually decrease the
insulation resistance of these windings.
3.4.2 TO CLEAN THE GENERATOR
• Use a damp cloth to wipe exterior surfaces clean.
• A soft, bristle brush may be used to loosen caked on dirt, oil,
etc.
• A vacuum cleaner may be used to pick up loose dirt and debris.
• Low pressure air (not to exceed 25 psi
(172 kPa)) may be
used to blow away dirt. Inspect cooling air slots and openings
on the generator. These openings must be kept clean and
unobstructed.
3.4.3 ENGINE MAINTENANCE
(000130)
WARNING
Accidental Start-up. Disconnect the negative battery
cable, then the positive battery cable when working
on unit. Failure to do so could result in death or serious
injury.
3.4.4 CHECKING OIL LEVEL
See the “Before Starting the Generatorsection for information on
checking the oil level. The oil level should be checked before each
use, or at least every eight hours of operation. Keep the oil level
maintained.
3.4.5 CHANGING THE OIL AND OIL FILTER
Change the oil and oil filter after the first 30 hours of operation.
Change the oil every 100 hours or every season thereafter. If
running this unit under dirty or dusty conditions, or in extremely
hot weather, change the oil more often.
Hot oil may cause burns. Allow engine to cool before
draining oil. Avoid prolonged or repeated skin exposure
with used oil. Thoroughly wash exposed areas with soap.
Use the following instructions to change the oil after the engine
cools down:
1. Clean area around oil drain plug.
2. Remove oil drain plug from engine and oil fill plug (or dipstick)
to drain oil completely into a suitable container.
3. When oil has completely drained, install oil drain plug and
tighten securely.
4. Place a suitable container beneath the oil filter and turn filter
counterclockwise to remove. Discard according to local
regulations.
5. Coat gasket of new filter with clean engine oil. Turn filter
clockwise until gasket contacts lightly with filter adapter. Then
tighten an additional 3/4 turn.
6. Fill engine with recommended oil. (See “Before Starting the
Generatorfor oil recommendations).
7. Wipe up any spilled oil.
8. Replace oil fill plug (or dipstick).
9. Dispose of used oil at a proper collection center.
3.4.6 REPLACING THE SPARK PLUG(S)
See Engine Specifications for recommended spark plug(s).
Replace the plug once each year. This will help the engine start
easier and run better.
1. Stop the engine and pull the spark plug wire(s) off of the spark
plug(s).
2. Clean the area around the spark plug(s) and remove it from the
cylinder head(s).
3. Set the spark plug's gap to 0.70-0.80 mm (0.028-0.031 in.).
Install the correctly gapped spark plug(s) into the cylinder
head(s) (Figure 20).
17
Maintenance
18
Figure 20 - Spark Plug Gap
000211
3.4.7 BATTERY REPLACEMENT (IF EQUIPPED)
The battery shipped with the generator has been provided fully
charged. Caution must be taken when connecting the battery.
NOTE: A battery may lose some of its charge when not in
use for prolonged periods of time. The battery may have to be
recharged before the first use. (See the "Know the Generator"
section.)
NOTE: For the 3.6kW - 8kW, order battery part number 0G9449.
For the 10kW, order battery part number 0H1663.
1. To replace the battery:
2. Slide the boots off of the battery terminals.
3. Disconnect the BLACK battery cable and the black battery
charger wire from the battery Negative terminal (–).
4. Disconnect the RED battery cable and the red battery charger
wire from the battery Positive terminal (+).
5. Remove the battery strap.
To install a new battery:
1. Reverse the steps above.
2. Double check all connections to ensure they are in the correct
location and secure. See Figure 3.
3. Secure battery with battery strap.
Battery Type: CP12-10, 12V, 10AH
3.4.8 AIR FILTER REPLACEMENT
The engine will not run properly and may be damaged if using
a dirty air cleaner. Clean or replace the air cleaner paper filter
once a year. Clean or replace more often if operating under dusty
conditions (Figures 21 through 23).
To clean or replace paper air filter:
1. Remove air cleaner cover and remove paper filter.
2. Clean paper filter by tapping it gently on a solid surface. If the
filter is too dirty, replace it with a new one. Dispose of the old
filter properly.
3. Clean air cleaner cover, then insert new paper filter into the
base of the air cleaner. Re-install air cleaner cover.
NOTE: To order a new air filter, please contact the nearest
authorized service center at 1-800-333-1322.
Figure 21 - 3.6kW Air Filter (Part Number 078601)
Base
Cover
Filter
Figure 22 - 6.5 & 8kW Air Filter (Part Number 073111)
BASE
FILTER
COVER
Figure 23 - 10kW Air Filter (Part Number 073111)
Maintenance
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

Generac XP6500E 0059340 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur