3com 3C17121 Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

‘roll
This guide covers the following products:
SuperStack
®
3 Switch 4300 10/100/1000BASE-T
Module (3C17121) provides one Ethernet port for
connection to your network.
SuperStack 3 Switch 4300 10/100/1000BASE-T Dual
Module (3C17122) provides two Ethernet ports for
connection to your network.
The procedures described in the User Guide assume that
you have a single port Module. If you have a Dual
Module the procedures are the same, except that
procedures relating to the port apply to each port on
the Dual Module.
The Module conforms to the full duplex implementation
of the Gigabit Ethernet standard, IEEE 802.3ab and has
an auto-negotiating 10/100/1000BASE-T port configured
as Auto MDI (crossover).
Alternatively, you can manually set the port to 10BASE-T
half duplex, 10BASE-T full duplex, 100BASE-TX half
duplex or 100BASE-TX full duplex. You can also
manually set the port to 1000BASE-T. The port uses
Category 5 copper cabling with an RJ-45 connector. The
maximum segment length is 100 m (328 ft) over
Category 5 twisted pair cable.
WARNING: RJ-45 Ports. These are shielded RJ-45 data
sockets. They cannot be used as standard traditional
telephone sockets, or to connect the unit to a traditional
PBX or public telephone network. Only connect RJ-45
data connectors, network telephony systems, or network
telephones to these sockets. Either shielded or
unshielded data cables with shielded or unshielded
jackets can be connected to these data sockets.
LEDs
You can gather information about the status of the
Module and its packet activity using the Expansion
Module port LEDs on the front of the Switch.
Switch Front Panel LED’s
I
NTRODUCTION
Module Packet LED
Appearance Color Meaning
On Green Packets are being transmitted or received
on the Module port.
Off No color There are no packets being transmitted or
received on the Module port.
Module Status LED
Appearance Color Meaning
On Green The Module is installed.
Off No color There is no Module installed or an
unsupported Module is fitted.
Module Panel LED
Appearance Color Meaning
On Green The Port has a link and is running at the
speed indicated.
Off No color The Port does not have a link.
SuperStack
®
3 Switch 4300 10/100/1000BASE-T Module (3C17121)
and Dual Module (3C17122) User Guide
DUA1712-1AAA01
1000
10
100
3C17121 SuperStack 3 Switch 4300 1000BASE-T
S/N: XXXX/7XXXXXXXXX
1
WARNING: Installation and removal of the Module must
be carried out by qualified personnel only. Before
installing the Module into a unit, you must first
disconnect the unit from the mains power supply. For
full safety instructions, refer to the user guide that
accompanies the unit.
AVERTISSEMENT: Confiez l'installation et la dépose de
ce Module à un personnel qualifié. Avant d'installer ce
Module dans un groupe, vous devez au préalable
débrancher ce groupe de l'alimentation secteur. Pour
prendre connaissance des consignes complètes de
sécurité, consultez le guide utilisateur qui accompagne
ce groupe.
WARNHINWEIS: Die Installation und der Ausbau des
Moduls darf nur durch Fachpersonal erfolgen. Vor dem
Installieren des Moduls in einem Gerät muß zuerst der
Netzstecker des Geräts abgezogen werden. Vollständige
Sicherheitsanweisungen sind dem Benutzerhandbuch des
Gets zu entnehmen.
WARNING: When the Module is inserted into the
switch, the captive screws securing the Module must be
tightened with a suitable tool. Keep the blanking plate
and the fixings in a safe place. If you remove the
Module at any time, you must then replace the blanking
plate.
AVERTISSEMENT: Quand le Module est inséré dans le
commutateur, visser le module, en le securisant
fortemant avec un outil adapté. Conservez la plaque
d'obturation et les fixations en lieu sûr. Si vous retirez le
Module à tout instant, vous devez alors replacer la
plaque d'obturation.
WARNHINWEIS: Beim Einsetzen des Moduls in dem
Switch sind die unverlierbaren Schrauben mit einem
passenden Werkzeug festzuziehen. Die Distanzplatte und
die Befestigungselemente an einem sicheren Ort
aufbewahren. Beim Austausch des Moduls ist auch die
Distanzplatte zu ersetzen.
WARNING: RJ-45 Ports. These are shielded RJ-45 data
sockets. They cannot be used as standard traditional
telephone sockets, or to connect the unit to a traditional
PBX or public telephone network. Only connect RJ-45
data connectors, network telephony systems, or network
telephones to these sockets.
Either shielded or unshielded data cables with shielded
or unshielded jackets can be connected to these data
sockets.
AVERTISSEMENT: Points d’accès RJ-45. Ceux-ci sont
protégés par des prises de données. Ils ne peuvent pas
être utilisés comme prises de téléphone conventionnelles
standard, ni pour la connection de l’unité à un réseau
téléphonique central privé ou public. Raccorder
seulement connecteurs de données RJ-45, systèmes de
réseaux de téléphonie ou téléphones de réseaux à ces
prises.
Il est possible de raccorder des câbles protégés ou non
protégés avec des jacks protégés ou non protégés à ces
prises de don
WARNHINWEIS: RJ-45-Porte. Diese Porte sind
geschützte Datensteckdosen. Sie dürfen weder wie
normale traditionelle Telefonsteckdosen noch für die
Verbindung der Einheit mit einem traditionellem
privatem oder öffentlichem Telefonnetzwerk gebraucht
werden. Nur RJ-45-Datenanscluße, Telefonnetzsysteme
or Netztelefone an diese Steckdosen anschließen.
Entweder geschützte oder ungeschützte Buchsen dürfen
an diese Datensteckdosen angeschlossen werden.
Handling the Module
The Module can be easily damaged by electrostatic
discharge. To prevent damage, observe the following:
Always wear an anti-static wristband connected to a
suitable earth point.
Do not remove the Module from its packaging until
you are ready to install it into a Switch.
Do not touch any of the pins, connections or
components on the Module.
Handle the Module only by its edges and front panel.
Always store or transport the Module in anti-static
packaging.
Installing the Module into a Switch
CAUTION: This Module is not hot-swappable. Always
make sure that the Switch is powered down and
disconnected from the mains before installing or
removing a Module. Use the following instructions when
installing or removing a Module.
To install the Module:
1
Ensure that the Switch is disconnected from the mains
power supply and that you are wearing an anti-static
wristband connected to a suitable earth point.
2
Undo the two screws securing the blanking plate at the
rear of the Switch using a suitable screwdriver. Do not
remove any other screws from the rear of the Switch.
3
Remove the blanking plate.
4
Hold the Module so that the text on the front panel is
upright and insert it into the Switch, ensuring the
connectors are fully engaged (see Figure 1
). Make sure
the Module is pushed fully in.
5
Secure the Module by tightening the two captive screws
with a screwdriver.
Keep the blanking plate in a safe place. If you remove
the Module at any time, you must replace the blanking
plate to prevent dust and debris entering the Switch.
Replacing the blanking plate will also help circulate
cooling air through the Switch.
Each Switch has the facility to accept up to two
Expansion Modules, allowing Gigabit Ethernet or Fast
Ethernet connections. Modules can be inserted into
either Expansion Module slot.
Figure 1
Inserting the Module into the Switch
I
NSTALLATION
AND
R
EMOVAL
2
Activating the Module
1
Ensure that the Switch is powered-up.
2
Plug the RJ-45 connector on the Category 5 cable into
the RJ-45 port on the Module.
3
Connect the other end of the Category 5 cable to a
device that supports 1000BASE-T.
4
Check the LEDs on the front of the Switch to ensure
that the Module is operating correctly. Refer to
LEDs
for more information.
Removing the Module from a Switch
1
Ensure that the power supply and the backbone
connection cables are disconnected from the Switch.
2
Undo the Modules two captive screws with a suitable
screwdriver. Do not remove any other screws from the
Switch.
3
Remove the Module.
4
If you are not fitting another Module immediately, you
must replace the blanking plate to ensure that dust and
debris do not enter the Switch. Replacing the blanking
plate will also help circulate cooling air through the
Switch.
When the Module is installed, you can configure it
through your Switch to add extra functionality. Refer to
the documentation that accompanies your Switch 4300
for more information.
The Switch 4300 dynamically assigns port numbers to
each Module installed, so if you add, replace or remove
a Module, the port number of the other Module may
change. The port numbers allocated depend on the type
of Module; the number of Modules installed and the
slots into which they are fitted.
Figure 2
shows how a single port Module, inserted into
Slot 2, will be assigned a port number of 49. If you then
insert an additional dual or a single port Module into
Slot 1 (see Figure 3
and Figure 4) the port numbering
will change. The port number originally assigned to the
Module in Slot 2 (and any port parameters you may
have set against that port number) will be re-assigned to
the Module installed into Slot 1. Similarly, if you then
remove the Module from Slot 1, the port number and
parameter settings will be re-assigned to the Module in
Slot 2.
CAUTION: Always check that each port number has the
correct parameter settings after adding, changing or
removing a Module. This is due to the method in which
the Switch dynamically assigns port numbers.
Figure 2
Rear View of Switch 4300
Module Port Number Allocation
Figure 3
Rear View of Switch 4300
Installing a Dual Port Module into Slot 1
Figure 4
Rear View of Switch 4300
Installing a Single Port Module into Slot 1
When using the Module port, note the following:
The Module only operates in full duplex mode for
1000BASE-T.
The Module operates in half and full duplex mode for
10BASE-T and 100BASE-TX.
The Module is not hot-swappable
The Module is not hot-insertable.
The Module only operates with Category 5 Ethernet
cable.
If you suspect a problem, carry out these steps before
contacting your supplier:
Ensure that the Module is correctly installed in the
Switch.
Ensure that the Switch in which the Module is fitted
is powered-up.
Ensure that the device at the far end of the line is
powered-up and operating correctly.
Check that all connectors on the Category 5 cable
are correctly engaged.
For information about technical support , refer to the
documentation supplied with your Supplier.
M
ANAGING
THE
M
ODULE
M
ODULE
P
ORT
R
ESTRICTIONS
P
ROBLEM
S
OLVING
3
The following options are available for technical support:
In the first instance contact your Network Supplier
Check the 3Com knowledgebase at http://knowledgebase.3com.com
Browse the 3Com web site on
http://www.3com.com
Please have your product model name, part number, hardware revision number and serial number along with all relevant details
of the problem to hand before calling your Network Supplier or 3Com on the numbers below.
T
ECHNICAL
S
UPPORT
Country Telephone Number Country Telephone Number Country Telephone Number
Asia, Pacific Rim
Australia
Hong Kong
India
Indonesia
Japan
Malaysia
New Zealand
Pakistan
Philippines
1 800 678 515
800 933 486
+61 2 9937 5085 or
000800 6501111
001 800 61 009
03 5783 1270
1800 801 777
0800 446 398
+61 2 9937 5083
1235 61 266 2602
P.R. of China
Singapore
S. Korea:
Taiwa n, R. O .C.
Thailand
10800 61 00137 or
021 6350 1590 or
00800 0638 3266
800 6161 463
00798 611 2230 or
02 3455 6455
0080 611 261
001 800 611 2000
Latin America
Brazil
Mexico
Puerto Rico
Central and South
America
0800 13 3266
01 800 849CARE
800 666 5065
AT&T +800 998 2112
Europe, Middle East
and Africa
From anywhere in these
regions, call:
+44 (0)1442 435529 phone
+44 (0)1442 436722 fax
Europe and South Africa
From the following countries, you may use the following toll-free numbers:
Austria
Belgium
Denmark
Finland
France
Germany
Hungary
0800 297468
0800 71429
800 17309
0800 113153
0800 917959
0800 1821502
06800 12813
Ireland
Israel
Italy
Luxembourg
Netherlands
Norway
Poland
1800 553117
1800 9453794
800 8 79489
0800 3625
0800 0227788
800 11376
00800 3111206
Portugal
South Africa
Spain
Sweden
Switzerland
U.K.
0800 831416
0800 995014
900 983125
020 795482
0800 55 3072
0800 966197
North America
1 800 NET 3Com (1 800 638 3266)
Enterprise Customers: 1 800 876 3266
Operating Temperature
0 to 40°C (32 to 105°F)
Operating Humidity
10 to 95% non-condensing
Power Consumption
10.6 W maximum
Safety Standards
UL 1950
EN60950
CSA 22.2#950
IEC 60950
Electromagnetic
Compatibility
CISPR22 Class A
EN55022 Class A
AS/NZS 3548 Class A
FCC Part 15 Class A
ICES-003 Class A
VCCI Class A
CNS 13438 Class A
Korean EMC Approval
EN55024
T
ECHNICAL
S
PECIFICATIONS
4
FCC Statement
This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to
part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful
interference when the equipment is operated in a
commercial environment. This equipment generates, uses
and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely
to cause harmful interference to radio communications, in
which case the user will be required to correct the
interference at their own expense.
Information To The User
If this equipment does cause interference to radio or
television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the
following measures:
Reorient the receiving antenna.
Relocate the equipment in relation to the receiver.
Move the equipment away from the receiver.
Plug the equipment into a different outlet so that
equipment and receiver are on different branch
circuits.
If necessary, the user should consult the dealer or an
experienced radio/television technician for additional
suggestions. The user may find the following booklet
prepared by the Federal Communications Commission
helpful:
How to Identify and Resolve Radio-TV Interference
Problems
This booklet is available from the U.S. Government
Printing Office, Washington, DC 20402, Stock No.
004-000-00345-4.
In order to meet FCC emissions limits, this equipment
must be used only with cables which comply with IEEE
802.3.
CE Statement (Europe)
This product complies with the European Low Voltage
Directive 73/23/EEC and EMC Directive 89/336/EEC as
amended by European Directive 93/68/EEC.
CSA Statement
This Class A digital apparatus meets all requirements of
the Canadian interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les
exigences du Règlement sur le matériel brouilleur du
Canada.
VCCI Statement
BSMI Statement
R
EGULATORY
N
OTICES
5
T
© 3Com Technologies, 2001.
All rights reserved. No part of this
documentation may be reproduced in any form or by any means or used
to make any derivative work (such as translation, transformation, or
adaptation) without permission from 3Com Technologies.
3Com Technologies reserves the right to revise this documentation and
to make changes in content from time to time without obligation on the
part of 3Com Technologies to provide notification of such revision or
change.
3Com Technologies provides this documentation without warranty of any
kind, either implied or expressed, including, but not limited to, the
implied warranties of merchantability and fitness for a particular purpose.
3Com may make improvements or changes in the product(s) and/or the
program(s) described in this documentation at any time.
UNITED STATES GOVERNMENT LEGENDS:
If you are a United States government agency, then this documentation
and the software described herein are provided to you subject to the
following restricted rights:
For units of the Department of Defense:
Restricted Rights Legend:
Use, duplication or disclosure by the
Government is subject to restrictions as set forth in subparagraph (c) (1)
(ii) for restricted Rights in Technical Data and Computer Software clause
at 48 C.F.R. 52.227-7013. 3Com Centre, Boundary Way, Maylands Park
South, Hemel Hempstead, Herts, HP2 7YU, U.K.
For civilian agencies:
Restricted Rights Legend:
Use, reproduction or disclosure is subject to
restrictions set forth in subparagraph (a) through (d) of the Commercial
Computer Software - Restricted Rights Clause at 48 C.F.R. 52.227-19 and
the limitations set forth in 3Com Corporations standard commercial
agreement for the software. Unpublished rights reserved under the
copyright laws of the United States.
If there is any software on removable media described in this
documentation, it is furnished under a license agreement included with
the product as a separate document, in the hard copy documentation, or
on the removable media in a directory file named LICENSE.TXT. If you are
unable to locate a copy, please contact 3Com and a copy will be
provided to you.
Unless otherwise indicated, 3Com registered trademarks are registered in
the United States and may or may not be registered in other countries.
3Com and SuperStack are registered trademarks of 3Com Corporation.
Other brand and product names may be registered trademarks or
trademarks of their respective holders.
L
EGAL
N
OTICES
6
General Environmental Statement
It is the policy of 3Com Corporation to be environmentally-friendly in all
operations. To uphold our policy, we are committed to:
Establishing environmental performance standards that comply
with national legislation and regulations
Conserving energy, materials and natural resources in all
operations
Reducing the waste generated by all operations
Ensuring that all waste conforms to recognized environmental
standards
Maximizing the recyclable and reusable content of all products
Ensuring that all products can be recycled, reused and disposed
of safely
Ensuring that all products are labelled according to recognized
environmental standards
Improving our environmental record on a continual basis
End Of Life Statement
3Com processes allow for the recovery, reclamation and safe disposal of
all end-of-life electronic components.
Regulated Materials Statement
3Com products do not contain any hazardous or ozone-depleting
material.
Environmental Statement about the Documentation
The documentation for this product is printed on paper that comes from
sustainable, managed forests; it is fully biodegradable and recyclable, and
is completely chlorine-free. The varnish is environmentally-friendly, and
the inks are vegetable-based with a low heavy-metal content.
E
NVIRONMENTAL
S
TATEMENTS
Product Registration
You can now register your 10/100/1000BASE-T Module (3C17121) and 10/100/1000BASE-T Dual Module (3C17122) on the
3Com web site at:
http://support.3com.com/registration/frontpg.pl
Documentation Feedback
Your suggestions are very important to us. They will help make our documentation more useful to you. Please e-mail comments
about this document to 3Com at:
pddtechpubs_comments@3Com.com
Please include the following information when commenting: the document title, part number, and page number, if appropriate.
Part Number: DUA1712-1AAA01
Rev.01
Published: March 2001
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

3com 3C17121 Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues