Sub-Zero 5230790 Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

UNDERCOUNTER ICE MACHINE
USE AND CARE GUIDE
CLEANING, MAINTENANCE, AND MORE
2
|
Sub-Zero Customer Care 800.222.7820
UNDERCOUNTER ICE MACHINE
Contents
4 Ice Machine Features
5 Operation
7 Care Recommendations
10 Water Filtration System Data
11 Troubleshooting
14 Sub-Zero Warranty
subzero.com
|
3
Customer Care
The model and serial number are printed on the enclosed
product registration card. Both numbers are also listed on
the product rating plate. Refer to page 4 for rating plate
location. For warranty purposes, you will also need the date
of installation and name of your authorized Sub-Zero dealer.
Record this information below for future reference.
SERVICE INFORMATION
Model Number
Serial Number
Date of Installation
Certied Service Name
Certied Service Number
Authorized Dealer
Dealer Number
If your product ever needs attention, be sure to use a
Sub-Zero Factory Certied Service provider recommended
by our customer care center, or select one from our list of
providers available at subzero.com/locator. All Factory Certi-
ed Service providers are carefully selected and thoroughly
trained by us.
UNDERCOUNTER ICE MACHINE
Important Note
To ensure this product is installed and operated as safely
and efciently as possible, take note of the following types
of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specied.
WARNING
PROPOSITION 65 FOR CALIFORNIA RESIDENTS
Cancer and Reproductive Harm—
www.P65Warnings.ca.gov
4
|
Sub-Zero Customer Care 800.222.7820
Ice Machine Features
FEATURES
1
Product Rating Plate
2
Control Panel
3
Water Shutters
4
Automatic Ice Maker
5
Large-Capacity Ice Storage Bin
6
Ice Scoop
7
Water Filter
ICE MACHINE FEATURES
6
4
2
3
7
Ice machine
1
5
Control Panel
FUNCTION
POWER Touch to turn the unit on or off. ‘POWER’ will illumi-
nate green when the ice machine in on.
ICE ‘ICE’ will illuminate blue when the unit is in ice
making operation.
DELAY Manual Delay: With the unit on, touch DELAY once
to initiate a 2-hour delay, twice for a 4-hour delay
and three times for an 8-hour delay. The corre-
sponding number will illuminate, then ash indicating
the delay period.
Auto Delay: With the unit off, touch DELAY once to
initiate a 2-hour delay, twice for a 4-hour delay and
three times for an 8-hour delay. The corresponding
number will illuminate, then ash indicating the delay
period. The delay will occur every 24 hours but must
be reset after a power outage. To cancel repeat
delay, turn the unit off, then back on.
CLEAN Touch to initiate the cleaning cycle. ‘CLEAN’ will illu-
minate green during the cleaning cycle and will ash
to signal time to add cleaner and sanitizer.
REPLACE
FILTER
When the unit completes 8000 ice making cycles,
‘REPLACE FILTER’ will illuminate red to indicate the
water lter needs to be replaced. Touch and hold
‘CLEAN’ for 6 seconds to reset the indicator.
Control panel
subzero.com
|
5
Operation
PRIOR TO USE
Clean the ice machine thoroughly with warm water and mild
detergent. Rinse and dry with a soft cloth to remove any
residual oil and grease left from the manufacturing process.
Refer to care recommendations on page 6.
All surfaces that come in contact with the water system
should be cleaned and sanitized prior to use. Refer to the
cleaning and sanitizing procedure on page 7. Use only the
cleaner and sanitizer made for the Sub-Zero ice machine.
Ice machine cleaner and sanitizer can be ordered online at
subzerowolfstore.com. For questions, contact Sub-Zero
customer care at 800-222-7820.
OPERATION
ICE PRODUCTION CYCLE
Depending on ambient conditions and water temperature,
one ice production cycle takes approximately 30 minutes.
1 Water ll cycle. The water inlet valve purges old water
from the system.
2 Refrigeration system start-up. The compressor starts
after the water ll cycle and remains on throughout the
freeze and harvest cycles. The condenser fan motor
starts and runs throughout the freeze cycle.
3 Freeze cycle. Water is sprayed into the inverted cups.
The water freezes layer by layer until an ice cube forms
in each cup. The control system adjusts the length of the
freeze cycle to conditions.
4 Harvest cycle. The evaporator warms, allowing the
cubes to be released and drop into the storage bin. The
control system adjusts the length of the harvest cycle
to conditions. At the end of the harvest cycle, another
freeze cycle begins.
5 Automatic shut-off. The level of ice in the storage bin
controls the automatic shut-off. When the bin is full, ice
will contact the bin thermostat, which cools, signaling ice
production to stop. When the ice level drops and ice no
longer contacts the bin thermostat, it will warm, signaling
ice production to resume.
6
|
Sub-Zero Customer Care 800.222.7820
OPERATION
Cleaning
INTERIOR CLEANING
To clean interior surfaces and all removable parts, wash with
a mild solution of soap, water and baking soda. Rinse and
dry thoroughly. Avoid getting water on lights and control
panel.
CAUTION
Do not use vinegar, rubbing alcohol or other alcohol-
based cleaners on any interior surface.
STAINLESS STEEL EXTERIOR
Use a nonabrasive stainless steel cleaner and apply with a
soft lint-free cloth. To bring out the natural luster, lightly wipe
surface with a water-dampened microber cloth followed by
a dry polishing chamois. Always follow the grain of stainless
steel.
Operation
CUBE WEIGHT
Cube weight increases or decreases depending on the
amount of dimple, or depression in the octagonal-shaped
ice cube. Cube weight can be adjusted by increasing the
freeze time.
To adjust cube weight:
1 Touch and hold ‘POWER’.
2 Touch and release ‘CLEAN’ once to add one minute of
freeze time. Inspect the cubes after several production
cycles and repeat if a heavier cube is desired. Up to ve
minutes of additional freeze time can be added.
3 Touch ‘CLEAN’ six times to reset freeze time to the
factory setting.
ICE LEVEL
A thermostat in the ice storage bin signals ice production to
stop when the bin is full. If ice production stops before the
bin is full or continues after the bin is full, the ice level can
be adjusted. The thermostat control is located behind the
kickplate. Refer to the illustration below.
To adjust ice level:
1 Remove the kickplate to access the thermostat control.
2 Turn the control to the left to decrease the level of ice or
to the right to increase the level.
THERMOSTAT
CONTROL
Ice level adjustment
subzero.com
|
7
CARE RECOMMENDATIONS
Cleaning and sanitizing procedure:
1 Touch ‘CLEAN’. A two-minute harvest cycle will remove
any remaining ice from the evaporator.
2 Remove all ice from the storage bin.
3 Wait three minutes until the CLEAN light ashes, then
lift the water shutters and pour 4 ounces
(115 ml) of undi-
luted ice machine cleaner directly into the spray area.
Refer to the illustration below.
4 A 10-minute cleaning cycle begins, followed by eight
rinse cycles. When the process is complete, the CLEAN
light will no longer be illuminated. The entire cleaning
cycle takes approximately 30 minutes.
5 Touch ‘CLEAN’. Wait three minutes until the CLEAN light
ashes, then lift the water shutters and pour 1 table-
spoon
(15 ml) of undiluted ice machine sanitizer directly
into the spray area.
6 A 10-minute sanitizing cycle begins, followed by eight
rinse cycles. When the process is complete, the CLEAN
light will no longer be illuminated. The entire sanitizing
cycle takes approximately 30 minutes.
Water shutters location
WATER
SHUTTERS
Cleaning
CLEANING AND SANITIZING
All surfaces that come in contact with the water system
should be cleaned and sanitized prior to use and every six
months using the following procedure. Use only the cleaner
and sanitizer made for the Sub-Zero ice machine.
Ice machine cleaner and sanitizer can be ordered online at
subzerowolfstore.com. For questions, contact Sub-Zero
customer care at 800-222-7820.
IMPORTANT NOTE: Poor water quality may require more
frequent cleaning and sanitizing. Consult a qualied profes-
sional to test water quality and recommend appropriate
water treatment.
8
|
Sub-Zero Customer Care 800.222.7820
Maintenance
WATER FILTER REPLACEMENT
The water lter should be replaced every six months, after
a prolonged shutdown or after 8000 ice making cycles.
‘REPLACE FILTER’ will illuminate on the control panel
indicating the water lter needs to be replaced. The ice
machine bypasses the lter when it is removed, so the water
supply does not need to be turned off.
Replacement Sub-Zero water lters can be ordered online
at subzerowolfstore.com. For questions, contact Sub-Zero
customer care at 800-222-7820.
IMPORTANT NOTE: Poor water quality may require more
frequent water lter replacement.
To replace water lter:
1 To remove the water lter, rotate one-quarter turn
counterclockwise and the lter will pop out. Refer to the
illustration below.
2 Reverse the process to install the new lter.
3 Touch and hold ‘CLEAN’ for 6 seconds to reset the
indicator.
Water lter location
WATER
FILTER
Cleaning
CONDENSER CLEANING
CAUTION
Before cleaning the condenser, turn power off at the
control panel. Wear gloves to avoid injury from sharp
condenser ns.
The condenser is located behind the kickplate. To access,
remove the kickplate. Use a soft bristle brush and vacuum
to remove dust and lint from the condenser. Clean the con-
denser every six months. Refer to the illustration below.
IMPORTANT NOTE: To avoid damaging condenser ns,
vacuum in the direction of the ns.
CAUTION
Failure to clean the condenser could result in tempera-
ture loss, mechanical failure or damage.
Condenser location
CONDENSER
CARE RECOMMENDATIONS
subzero.com
|
9
CARE RECOMMENDATIONS
Maintenance
PROLONGED SHUTDOWN
If the ice machine is to be removed from service for an
extended period or exposed to temperatures of 32°F
(0°C)
or below, follow the procedure for prolonged shutdown and
winterization.
Prolonged shutdown and winterization procedure:
1 Perform the cleaning and sanitizing procedure on page 7
to prevent mildew growth.
2 Disconnect electrical power at the circuit breaker or
service panel.
3 Turn off the water supply.
4 Remove water from the water reservoir.
5 Disconnect the incoming water supply line at the rear of
the unit and allow it to drain.
6 Disconnect the vinyl hose from the water pump and
allow it to drain.
7 Verify water is not trapped in any of the water supply or
drain lines. Compressed air can be used to blow out the
lines.
8 Use a spray bottle with a solution of 1 tablespoon (15 ml)
sanitizer to 1 gallon
(3.8 L) water and spray all interior
surfaces. Do not rinse, allow it to air dry.
9 Block the door partially open to provide air exchange
and prevent mildew growth.
10
|
Sub-Zero Customer Care 800.222.7820
APPLICATION GUIDELINES | WATER SUPPLY PARAMETERS
For cold water use only.
Capacity: 2,800 gallons (10,600 liters) depending on local water conditions
Service ow: 0.75 gpm (2.84 lpm)
Water supply: Community or private well
Water pressure: 25–125 psi (172–862 kPa)
Water temperature: 35°F–100°F (1.7°C–38°C)
SPECIAL NOTES
It is essential that operational, maintenance and lter replacement requirements be carried out for this product to perform as advertised. Change
cartridges every 6 months. Use replacement cartridges 7012333.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Systems must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary.
Manufactured for: Sub-Zero, Inc., P.O. Box 44848, Madison, WI 53744, 800-222-7820
WATER FILTRATION SYSTEM PERFORMANCE DATA
SUB-ZERO WATER FILTRATION SYSTEM MODEL 56145 (REPLACEMENT CARTRIDGE 7012333)
System tested and certied by NSF International against NSF/ANSI Standard 42 for the
reduction of Chlorine Taste and Odor, Particulate Class III.
Average Inuent
Concentration
Inuent Challenge
Concentration—
Units apply
to each row
Average Product
Water
Concentration
Average %
Reduction
NSF Reduction
Requirements NSF TestContaminant Reduction
Particulate
Class III Particle size: >5 to <15 um
6533
At least 10,000
particles/ml
1479 97.7 ≥ 85% 516550-05
Chlorine, Taste and Odor 2.1 2.0 mg/L ± 10% 0.27 87.1 ≥ 50% 516549-05
WATER FILTER CARTRIDGE LIMITED WARRANTY
Sub-Zero will repair or replace any lter cartridge which proves to be defective in materials or workmanship for a period of one year from the
date of purchase. The warranty does not cover routine replacement due to normal use. For warranty claims, call 800-222-7820.
The warranty applies only to products installed in any one of the fty states of the United States, the District of Columbia or the ten provinces
of Canada. This warranty does not cover any parts or labor to correct any defect caused by local poor water quality, negligence, accident or
improper use, maintenance, installation, service or repair.
The remedies described above for each warranty are the only ones that Sub-Zero will provide, either under these warranties or under any
warranty arising by operation of law. Sub-Zero will not be responsible for any consequential or incidental damages arising from the breach of
these warranties or any other warranties, whether express, implied or statutory.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply
to you. This warranty gives you specic legal rights and you may also have other legal rights, which vary from state to state.
These systems have been tested according to Standard NSF/ANSI 42 for the reduction of the substances listed below. The concentration of the indi-
cated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system
as specied in NSF/ANSI 42.
CONTAMINANT REDUCTION DETERMINED BY NSF TESTING
subzero.com
|
11
TROUBLESHOOTING
Troubleshooting
UNIT OPERATION
Ice machine does not operate.
Verify power is on.
Verify electrical power to ice machine and home circuit
breaker is on.
No light.
LED interior lighting must be replaced by Sub-Zero
Factory Certied Service.
Ice machine operates, but no ice is produced.
Verify connection to water supply.
Verify water lter is not clogged. Replace water lter,
then follow cleaning and sanitizing procedure on page 7.
Verify spray nozzles are not blocked. Follow cleaning and
sanitizing procedure on page 7.
Verify water pressure at 20 psi
(1.4 bar) to 80 psi (5.5 bar).
Verify bin thermostat adjustment, refer to page 5.
Verify ambient air temperature between 50°F
(10°C) and
100°F
(40°C) for indoor model and between 50°F (10°C)
and 110°F
(45°C) for outdoor model.
Unit requires frequent cleaning and sanitizing.
Consult a qualied professional to test water quality and
recommend appropriate water treatment.
Contact Sub-Zero Factory Certied Service to disas-
semble unit and thoroughly clean and sanitize.
ICE PRODUCTION
Low ice production.
Clean condenser area, refer to page 8.
Verify connection to cold water supply.
Verify water lter is not clogged. Replace water lter,
then follow cleaning and sanitizing procedure on page 7.
Verify operation of water inlet valve.
Verify ambient air temperature between 50°F
(10°C) and
100°F
(40°C) for indoor model and between 50°F (10°C)
and 110°F
(45°C) for outdoor model.
Contact Sub-Zero Factory Certied Service if unre-
solved.
Poor ice quality, cubes are shallow, incomplete or white.
Follow cleaning and sanitizing procedure on page 7.
Replace water lter, refer to page 8.
Adjust cube weight, refer to page 5.
Verify water softener is working properly (if applicable).
Consult a qualied professional to test water quality and
recommend appropriate water treatment.
Contact Sub-Zero Factory Certied Service to disas-
semble unit and thoroughly clean and sanitize.
12
|
Sub-Zero Customer Care 800.222.7820
TROUBLESHOOTING
Troubleshooting
SERVICE
Maintain the quality built into your product by contacting
Sub-Zero Factory Certied Service. For the name of the
nearest Sub-Zero Factory Certied Service, check the
Support and Service section of our website, subzero.com
or call Sub-Zero customer care at 800-222-7820.
When contacting service, you will need the model and
serial number of your unit. Both numbers are listed on
the product rating plate. Refer to page 4 for rating plate
location.
For warranty purposes, you will also need the date
of installation and name of your authorized Sub-Zero
dealer. This information should be recorded on page 3.
subzero.com
|
13
Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf &
Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries.
All other trademarks are property of their respective owners in the United States and other countries.
Sub-Zero Residential Limited Warranty
FOR RESIDENTIAL USE
FULL TWO YEAR WARRANTY*
For two years from the date of original installation, this Sub-Zero product warranty covers all parts and
labor to repair or replace, under normal residential use, any part of the product that proves to be defec-
tive in materials or workmanship. All service provided by Sub-Zero under the above warranty must be
performed by Sub-Zero factory certied service, unless otherwise specied by Sub-Zero, Inc. Service will
be provided during normal business hours.
FULL FIVE YEAR SEALED SYSTEM WARRANTY
For ve years from the date of original installation, this Sub-Zero product warranty covers all parts and
labor to repair or replace, under normal residential use, these parts that prove to be defective in materials
or workmanship: compressor, condenser, evaporator, drier and all connecting tubing. All service provided
by Sub-Zero under the above warranty must be performed by Sub-Zero factory certied service, unless
otherwise specied by Sub-Zero, Inc. Service will be provided during normal business hours.
LIMITED TWELVE YEAR SEALED SYSTEM WARRANTY
For twelve years from the date of original installation, Sub-Zero will repair or replace the following parts
that prove to be defective in materials or workmanship: compressor, condenser, evaporator, drier and all
connecting tubing. If the owner uses Sub-Zero factory certied service, the service provider will repair or
replace these parts with the owner paying for all other costs, including labor. If the owner uses non-certi-
ed service, the owner must contact Sub-Zero, Inc. (using the information below) to receive repaired or
replacement parts. Sub-Zero will not reimburse the owner for parts purchased from non-certied service
or other sources.
TERMS APPLICABLE TO EACH WARRANTY
The warranty applies only to products installed for normal residential use. The warranty applies only to
products installed in any one of the fty states of the United States, the District of Columbia or the ten
provinces of Canada. This warranty does not cover any parts or labor to correct any defect caused by
negligence, accident or improper use, maintenance, installation, service or repair.
THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT SUB-ZERO, INC.
WILL PROVIDE, EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION OF
LAW. SUB-ZERO, INC. WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES
ARISING FROM THE BREACH OF THIS WARRANTY OR ANY OTHER WARRANTY, WHETHER EXPRESS,
IMPLIED OR STATUTORY.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty gives you specic legal rights and you may also
have other legal rights that vary from state to state.
To receive parts and/or service and the name of Sub-Zero factory certied service nearest you, contact
Sub-Zero, Inc., P.O. Box 44848, Madison, WI 53744; check the contact & support section of our website,
subzero.com, email us at [email protected] or call 800-222-7820.
*Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited
60-day parts and labor warranty for cosmetic defects.
*Replacement water lters and air purication cartridges are not covered by the product warranty.
Sub-Zero Outdoor Limited Warranty*
FOR RESIDENTIAL USE
FULL ONE YEAR WARRANTY**
For one year from the date of original installation, this Sub-Zero product warranty covers all parts and labor
to repair or replace, under normal residential use, any part of the product that proves to be defective in
materials or workmanship. All service provided by Sub-Zero under the above warranty must be performed
by Sub-Zero factory certied service, unless otherwise specied by Sub-Zero, Inc. Service will be provided
during normal business hours.
FULL FIVE YEAR SEALED SYSTEM WARRANTY
For ve years from the date of original installation, this Sub-Zero product warranty covers all parts and
labor to repair or replace, under normal residential use, these parts that prove to be defective in materials
or workmanship: compressor, condenser, evaporator, drier and all connecting tubing. All service provided
by Sub-Zero under the above warranty must be performed by Sub-Zero factory certied service, unless
otherwise specied by Sub-Zero, Inc. Service will be provided during normal business hours.
TERMS APPLICABLE TO EACH WARRANTY
The warranty applies only to products installed for normal residential use. The warranty applies only to
products installed in any one of the fty states of the United States, the District of Columbia or the ten
provinces of Canada. This warranty does not cover any parts or labor to correct any defect caused by
negligence, accident or improper use, maintenance, installation, service or repair.
THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT SUB-ZERO, INC.
WILL PROVIDE, EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION OF
LAW. SUB-ZERO, INC. WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES
ARISING FROM THE BREACH OF THIS WARRANTY OR ANY OTHER WARRANTY, WHETHER EXPRESS,
IMPLIED OR STATUTORY.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty gives you specic legal rights and you may also
have other legal rights that vary from state to state.
To receive parts and/or service and the name of Sub-Zero factory certied service nearest you, contact
Sub-Zero, Inc., P.O. Box 44848, Madison, WI 53744; check the contact & support section of our website,
subzero.com, email us at [email protected] or call 800-222-7820.
*Product must be approved for outdoor use, designated by model and serial number.
**Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited
60-day parts and labor warranty for cosmetic defects.
**Replacement water lters are not covered by the product warranty.
2
|
Atención al cliente de Sub-Zero 800.222.7820
MÁQUINA DE HIELO EMPOTRADA
Contenido
4 Características del generador de hielo
5 Funcionamiento
7 Recomendaciones sobre el cuidado
10 Datos del sistema de ltrado de agua
11 Resolución de problemas
14 Garantía Sub-Zero
subzero.com
|
3
Atención al cliente
El modelo y número de serie están impresos en la tarjeta
de registro del producto adjunta. Los dos números también
aparecen en la placa de datos del producto. Consulte la
página 4 para encontrar la placa de datos. Para nes de
la garantía, también necesitará la fecha de instalación y el
nombre de su distribuidor autorizado de Sub-Zero. Anote
esta información abajo para referencia futura.
INFORMACIÓN PARA SERVICIO
Número de modelo
Número de serie
Fecha de instalación
Nombre de servicio certicado
Número de servicio certicado
Distribuidor autorizado
Número de distribuidor
Si su producto alguna vez necesita servicio, use un pro-
veedor de servicios certicado por Sub-Zero y recomendado
por nuestro centro de atención al cliente, o seleccione uno
de nuestra lista de proveedores disponibles en subzero.com/
locator. Todos los proveedores de los centros de servicio
autorizados han sido cuidadosamente seleccionados y entre
-
nados a fondo por nosotros.
Aviso importante
Para garantizar que este producto se instale y opere de
la forma más segura y eciente posible, tome nota de los
siguientes tipos de información resaltada en esta guía:
AVISO IMPORTANTE señala la información que es especial-
mente importante.
PRECAUCIÓN indica una situación en la que se pueden
sufrir heridas leves o provocar daños al producto si no se
siguen las instrucciones.
ADVERTENCIA indica peligro de que se produzcan heridas
graves o incluso la muerte si no se siguen las precauciones.
AVISO IMPORTANTE: en toda esta guía, las dimensiones
entre paréntesis son milímetros, a menos que se especi-
que lo contrario.
ADVERTENCIA
PROPUESTA 65 PARA RESIDENTES DE CALIFORNIA
Cáncer y Daño Reproductivo—
www.P65Warnings.ca.gov
MÁQUINA DE HIELO EMPOTRADA
4
|
Atención al cliente de Sub-Zero 800.222.7820
Características de la máquina de hielo
CARACTERÍSTICAS
1
Placa de datos del producto
2
Panel de control
3
Obturadores de agua
4
Fábrica automática de hielo
5
Recipiente de almacenamiento de hielo de gran capacidad
6
Pala de hielo
7
Filtro de agua
CARACTERÍSTICAS DE LA MÁQUINA DE HIELO
6
4
2
3
7
Máquina de hielo
1
5
Panel de control
FUNCIÓN
POWER
(POTENCIA)
Pulse para encender y apagar la máquina.
‘POWER’ se iluminará de color verde cuando la
máquina de hielo esté encendida.
ICE (HIELO) ‘ICE’ se iluminará de color azul cuando la máquina
esté produciendo hielo.
DELAY
(RETRASO)
Retraso manual: pulse una vez para iniciar un
retraso de 2 horas en la producción de hielo, pulse
una segunda vez para un retraso de 4 horas y una
tercera vez para un retraso de 8 horas. Se iluminará
el número correspondiente indicando el período de
retraso. Pulse una cuarta vez para cancelar.
Retraso automatique: con la unidad apagada,
toque DEMORA una vez para iniciar un retraso de
2 horas, dos veces para un retraso de 4 horas y
tres veces para un retraso de 8 horas. El número
correspondiente se iluminará y luego parpadeará
para indicar el período de demora. La demora ocu-
rrirá cada 24 horas, pero se debe reiniciar después
de un corte de energía. Para cancelar el retraso
repetido, apague la unidad y vuelva a encenderla.
CLEAN
(LIMPIAR)
Pulse para iniciar el ciclo de limpieza. ‘CLEAN’
se iluminará de color verde durante el ciclo de
limpieza y parpadeará para indicar el momento de
agregar limpiador y desinfectante.
REPLACE
FILTER
(CAMBIAR
FILTRO)
Cuando la máquina haya realizado 8000 ciclos de
producción de hielo, ‘REPLACE FILTER’ se iluminará
de color rojo para indicar que el ltro de agua se
debe cambiar. Mantenga presionado ‘CLEAN’
durante 6 segundos para restablecer el indicador.
Panel de control
subzero.com
|
5
Funcionamiento
ANTES DE USARLO
Limpie cuidadosamente la máquina de hielo con agua tibia
y detergente suave. Enjuague y seque con un paño suave
para eliminar los residuos de aceite y grasa residual que
dejó el proceso de fabricación. Consulte las recomenda-
ciones sobre el cuidado en la página 6.
Todas las supercies que entren en contacto con el sistema
de agua deben limpiarse y desinfectarse antes de usarlas.
Consulte el procedimiento de limpieza y desinfección en la
página 7. Solo use un limpiador y desinfectante elaborados
para la máquina de hielo Sub-Zero.
El limpiador y desinfectante para generadores de hielo
Sub-Zero se pueden solicitar por Internet en subzerowolf
store.com. Si tiene alguna pregunta, comuníquese con la
línea de atención al cliente de Sub-Zero al 800-222-7820.
OPERACIÓN
CICLO DE PRODUCCIÓN DE HIELO
Según las condiciones ambientales y la temperatura del
agua, un ciclo de producción de hielo tarda aproximada-
mente 30 minutos.
1 Ciclo de llenado de agua. La válvula de admisión de
agua purga el agua que está en el sistema.
2 Puesta en marcha del sistema de refrigeración.
El compresor arranca después del ciclo de llenado de agua
y se mantiene encendido durante los ciclos de congelado y
recogida. El motor del ventilador del condensador arranca
y funciona durante el ciclo de congelado.
3 Ciclo de congelado. Se rocía agua en las tazas invertidas.
El agua se congela capa por capa hasta que se forma un
cubo de hielo en cada taza. El sistema de control ajusta la
duración del ciclo de congelado a las condiciones.
4 Ciclo de recogida. El evaporador calienta, con lo cual
los cubos se sueltan y caen en el recipiente de almace-
namiento. El sistema de control ajusta la duración del
ciclo de recogida a las condiciones. Al nal del ciclo de
recogida, comienza otro ciclo de congelado.
5 Apagado automático. El nivel de hielo en el recipiente
de almacenamiento controla el apagado automático.
Cuando el recipiente está lleno, el hielo entra en con-
tacto con el termostato del recipiente, que se enfría
e indica que la producción debe terminar. Cuando el
nivel de hielo baja y este ya no está en contacto con el
termostato del recipiente, se calentará, lo que indica que
la producción de hielo se debe reanudar.
6
|
Atención al cliente de Sub-Zero 800.222.7820
OPERACIÓN
Limpieza
LIMPIEZA INTERIOR
Para limpiar las supercies interiores y todas las piezas
móviles, lave con una solución suave de jabón, agua y
bicarbonato de sodio. Enjuague y seque completamente.
Evite que el agua entre en contacto con las luces y el panel
de control.
PRECAUCIÓN
No use vinagre, alcohol ni otros limpiadores a base de
alcohol en ninguna supercie interna.
EXTERIOR DE ACERO INOXIDABLE
Use un limpiador no abrasivo para acero inoxidable y
aplique con un paño suave sin pelusa. Para resaltar el lustre
natural, limpie suavemente la supercie con una tela de
microbra humedecida con agua, seguida con una gamuza
para pulir en seco. Siempre siga la dirección del acabado
del acero inoxidable.
Funcionamiento
PESO DE LOS CUBOS
El peso de los cubos aumenta o disminuye según la can-
tidad de hendiduras o depresiones en el cubo de hielo de
forma octagonal. El peso de los cubos se puede ajustar al
aumentar el tiempo de congelado.
Para ajustar el peso de los cubos:
1 Mantenga presionado ‘POWER’.
2 Pulse y suelte ‘CLEAN’ una vez para agregar un minuto
de tiempo de congelado. Revise los cubos después de
varios ciclos de producción y repita si desea un cubo
más pesado. Puede agregar hasta cinco minutos de
tiempo de congelado extra.
3 Pulse ‘CLEAN’ seis veces para restablecer el tiempo de
congelado a la conguración de fábrica.
NIVEL DE HIELO
Un termostato en el recipiente de almacenamiento de hielo
indica que la producción debe terminar cuando el reci-
piente está lleno. Si la producción se detiene antes de que
el recipiente esté lleno o continúa después, el nivel de hielo
se puede ajustar. El control del termostato se encuentra
situado detrás del zócalo. Consulte la siguiente ilustración.
Para ajustar el nivel de hielo:
1 Retire el zócalo para acceder al control del termostato.
2 Gire el control hacia la izquierda para disminuir el nivel
de hielo o hacia la derecha para aumentar el nivel.
CONTROL DEL
TERMOSTATO
Ajuste del nivel de hielo
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Sub-Zero 5230790 Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à