Lithonia Lighting OLAW23 53K 120 PE BZ Guide d'installation

Taper
Guide d'installation
This product comes with a:
FIVE YEAR LIMITED WARRANTY
Register your warranty on
www.lightahome.com/warranty
Your prompt product registration confirms your right to the protection available
under the terms and conditions of your Lithonia Lighting warranty.
Page 1 UOLAW 07/11
INSTALLATION INSTRUCTIONS / INSTRUCCIONES DE INSTALACION / DIRECTIVES D’INSTALLATION
LED Dusk to Dawn Security Area/Wall light
Paquete para montar en la pared de Lámparas LED nocturnas de seguridad
Appareil d’éclairage nocturne automatique DEL pour zone de sécurité/éclairage mural
Visit lightahome.com to find complementary fixtures and much more.
Customer Support • Our Complete Product Catalog Product Instruction Sheets
Energy Saving Tips • Product Specifications • Glossary of Lighting Terms
Page 8
Consumer Products Group/Acuity Brands Lighting, Inc.
One Lithonia Way, Conyers, GA 30012
www.lightahome.com
Protect yourself. Before installing, read
these instructions carefully and save them
for future reference.
Date Installed:___________________
Failure to follow any of these instructions
could void product warranties. For a
complete list of product Terms and
Conditions, visit
www.acuitybrands.com.
Acuity Brands Lighting, Inc. assumes no
responsibilities for claims arising out of
improper or careless installation or
handling of its products.
Pour votre propre protection. Avant de
procéder à l’installation, veuillez lire attentivement
ces directives et les conserver pour référence
ultérieure.
Date de l’installation :__________________
Tout manquement au respect de ces
instructions pourrait rendre nulles les
garanties. Pour une liste complète des
conditions générales du produit, veuillez
vous rendre sur www.acuitybrands.com.
Acuity Brands Lighting, Inc. n’assume
aucune responsabilité pour les réclamations
découlant d’une installation ou d’une
manipulation incorrectes ou négligentes de
ses produits.
Protéjase. Antes de instalar, lea estas
instrucciones cuidadosamente
y guárdelas para futura referencia.
Fecha Instalada:_________________
El incumplimiento de alguna de estas
instrucciones puede anular la garantía del
producto. Para obtener la lista completa de
los términos y las condiciones respecto al
producto, visite www.acuitybrands.com.
Acuity Brands Lighting, Inc. no se hace
responsable por los reclamos que puedan
surgir de la instalación o manipulación
inadecuada o negligente de sus productos.
Trouble Shooting Guide
If this fixture fails to operate properly,
use the guide below to diagnose
and correct the problem.
If light does not come on:
Verify that power is turned on at
switch and breaker
Verify that fixture is wired properly
Verify that line voltage is correct.
Test if Photocontrol works properly
The photocontrol in this fixture is
designed to turn on fixture light at
low light levels. During daylight in-
stallation light should come on and
then go off.
If light does not come on or stays
on:
Test if Photocontrol works properly:
Cover Photocontrol - Light should
come on.
Shine a flashlight into Photocontrol
- Light should go off.
If fixture cylcles on and off:
Light reflecting back off any surround-
ing surfaces enter the photocontol. To
correct problem, adjust Photocontrol
cover. If Photocontrol cover is in
closed position, it will allow operation
of fixture during daylight.
If further assistance is required, con-
tact:
Technical Support at: (800) 748-5070
This LED light provides low mainte-
nance service with no bulbs to
change. Clean surfaces with mild
soap and water. Do not use abra-
sive materials such as scouring
pads or powders, steel wool or
abrasive paper.
WARNING: There are no user
serviceable parts inside fixture
.
Guía de Localización de Averías
Si este luminario falla de operar
apropiadamente, use la siguiente guía para
diagnosticar y corregir el problema.
Verifique que el luminario este alambrado
apropiadamente
Verifique que el luminario este conectado
tierra correctamente
El voltaje de la línea en el luminario este
correcto
No hay ninguna luz reflejada hacia atrás
adentro de la foto celda que cause que
el luminario se ague.
El fotocontrol en este luminario esta
diseñado para encender la luz del
luminario en bajos niveles de luz.
Durante instalación a la luz del día, la luz
debe encender y luego apagarse.
Si la luz no enciende o se mantiene
encendida:
Prueba si el Fotocontrol esta trabajando
correctamente:
Cubra el Fotocontrol - La luz deberá
encenderse.
Brille una linterna en el Fotocontrol -
La luz deberá apagarse.
Si el luminario enciende y apaga en
ciclos:
Luz de alguna superficie reflectora esta
entrando en el fotocontol. Para corregir
algun problema, ajuste la tapa del
Fotocontrol. Si la cobertura de
Photocontrol está en la posición cerrada,
permitirá la operación del luminario durante
la luz del día y este luminario.
Si requiere ayuda adicional, contacte:
Technical Support al: (800) 748-5070
Esta lámpara LED con detector de
movimiento necesita muy poco
mantenimiento y no es necesario cambiar
los focos. Limpie las superficies con un
limpiador suave no abrasivo.
ADVERTENCIA: La cabeza de la lámpara
no contiene piezas que el usuario puede
reparar.
Guide de dépannage:
Si l’appareil ne fonctionne pas adéquatement,
veuillez vous servir du guide ci-dessous afin
d’identifier et corriger le problème.
Vérifier si le câblage de l’appareil est bien
fait.
Vérifier si la mise à la terre de l’appareil est
adéquate.
Vérifier la tension de secteur de l’appareil.
Vérifier toute lumière réfléchie sur la cellule
photoélectrique causant la mise hors
tension.
L’interrupteur photoélectrique de cet
appareil est conçu pour allumer l’éclairage
lorsque l’intensité lumineuse
environnante faiblit. Si l’installation est faite
durant le jour, la lumière devrait s’allumer
pendant puis s’éteindre.
Si la lumière ne s’allume pas ou reste
allumée:
Vérifier si l’interrupteur photoélectrique
fonctionne correctement:
Couvrir l’interrupteur photoélectrique
pendant et la lumière devrait s’allumer.
Diriger la lumière d’une lampe de poche
sur l’interrupteur photoélectrique, la lumière
devrait s’éteindre.
Si l’appareil d’éclairage s’allume puis
s’éteint en boucle:
L’interrupteur photoélectrique perçoit une
lumière réfléchie de surfaces avoisinantes.
Pour corriger le problème, ajuster le cache de
l’interrupteur photo-électrique. Si le couvercle
de l’interrupteur photo-électrique est en
position fermée, il permettra le onctionnement
du luminaire en pleine lumière du jour et
l’appareil ne sera.
Pour toute autre assistance, veuillez contacter
nos services de support technique:
Technical Support : (800) 748-5070
Cette lampe à détecteur de mouvement DEL
nécessite peu d’entretien et il n’y a aucune
ampoule à changer. Nettoyez les surfaces
avec un produit doux non abrasif.
AVERTISSEMENT: Il n’y a aucune pièce
réparable à l’intérieur de chaque projecteur.
Trouble Shooting Guide Guía de Localización de Averías
Guide de dépannage:
Model Number / Número de Modelo / Numéro des modèle
OLAW
GUÍA DE PASO-A-PASO
4. PRECAUCIÓN: OPERACIÓN DEL LUMINARIO Y
ALAMBRADO
Cerciórese que la fuente de alimentación eléctrica este
apagada.
Para poner a tierra el luminario, utilice una Tuerca de
Alambres para conectar el alambre de tierra de suministro de
la casa y el alambre (cobre) de tierra del luminario (cobre).
Nota: Si el alambrado de la casa no incluye un alambre de
Conexión a Tierra, consulte su código eléctrico local para
métodos aprobados para conectar a tierra.
CONEXIÓN DEL SUMINISTRO ELÉCTRICO
Use capuchones de alambres para conectar los dos
alambres negro del luminario al alambre negro del suministro
de electricidad de la casa y los dos alambres blanco del
luminario al blanco (neutral) del suministro de electricidad de
la casa.
Para una conexión apropiada, coloque el capuchón
de alambre sobre los alambres y gire en el sentido
de las agujas del reloj hasta que este apretado.
5. Encienda la electricidad en la caja de fusibles o caja de
cortacircuitos y verifique el éxito de la instalación.
Nota: Ajuste el control fotográfico para que la ventana
quede completamente abierta.
6. Aplique calafatea de silicona (no incluida) alrededor del
perímetro de la Placa Trasera para Un sello contra la
humedad.
Esta lámpara LED con detector de movimiento necesita muy
poco mantenimiento y no es necesario cambiar los focos.
Limpie las superficies con un limpiador suave no abrasivo.
ADVERTENCIA: La cabeza de la lámpara no contiene
piezas que el usuario puede reparar.
GUIDE DÉTAILLÉ
4. Pour MISE EN GARDE: CÂBLAGE ET MODE D’EMPLOI
DE L’APPAREIL
Vous assurer de couper le courant avant de procéder au
câblage.
Pour la mise à terre de l’appareil, connecter le fil de terre de
l’alimentation (cuivre) au fil de terre (cuivre) de l’appareil, à
l’aide d’un capuchon de connexion.
Note: Si le câblage d’alimentation ne comprend pas un fil
de mise à la terre, consulter votre code d’électricité lo
cal et vérifier les méthodes conformes pour la mise à la
terre.
RACCORDEMENT DE L’ALIMENTATION
Employer des capuchons de connexion (6) pour connecter
les deux fils noirs de l’appareil au fil d’alimentation noir et les
deux fils blancs au fil blanc (neutre) d’alimentation.
Pour vous assurer d’un bon raccordement, mettre le
capuchon sur les fils et tourner dans le sens de
rotation horaire jusqu’à ce que la connexion soit solide.
5. Rétablir le courant au fusible ou au disjoncteur et
vérifier si l’installation est réussie.
Remarque: Régler le photocontrôle de sorte que le
volet soit complètement ouvert.
6. Applique du bouche-fentes à la silicone (non inclus)
sur le périmètre de l’appareil là où il entre en contact
avec la surface de montage.
Si le découpage complet est nécessaire, aligner l’écran de
protection le long du bord extérieur de la lentille et faire
pression pour l’emboîter.
Cette lampe à détecteur de mouvement DEL nécessite peu
d’entretien et il n’y a aucune ampoule à changer. Nettoyez les
surfaces avec un produit doux non abrasif.
AVERTISSEMENT: Il n’y a aucune pièce réparable à
l’intérieur de chaque projecteur.
3C.Montage surface et conduit : voir Fig.C
Utilisez la plaque de montage [8] comme modèle pour
marquer les emplacements des trous de montage et forer des
avant-trous de 3/16 po de diamètre. Installez partiellement les
vis de montage (matériel inclus pour montage sur surfaces en
bois uniquement) Remarque: Assurez-vous que la fixation
est montée sur une surface structurellement solide qui
supportera le poids de la fixation.
Retirez le panneau d’accès [14] Remarque : un câble de
sécurité maintiendra temporairement le panneau. Faites
passer les câbles d’alimentation de la maison à travers la
plaque de montage et le collier de la fixation ou, si un conduit
est utilisé, à travers le trou d’excès du conduit (13) et dans le
compartiment de câblage de la fixation.
Alignez le trou de serrure et les emplacements sur la plaque
de montage avec les trois vis de montage partiellement
installées et serrez les vis de montage pour sécuriser la
fixation.
Utilisez des capuchons de connexion pour réaliser les
connexions de câblage à l’intérieur du compartiment de
câblage comme indiqué dans les instructions de l’étape 4.
Poussez les connexions de câblage dans le compartiment de
fixation et réinstallez le panneau d’accès.
3C. Montaje de superficie y de conducto: ver Fig. C
Use la placa de montaje [8] como plantilla para marcar los
puntos de orificios de montaje y perfore orificios piloto de
3/16" de diámetro. Instale parcialmente los tornillos de
montaje (componentes incluidos para montar en superfi-
cies de madera únicamente) Nota: Asegúrese de que el
montaje esté montado en una superficie estructuralmente
sólida que soporte el peso del montaje.
Quite el panel de acceso [14] Nota: Un amarre de
seguridad sostendrá temporalmente el panel. Pase los
cables del suministro por la placa de montaje y el collarín
del montaje o, si se usa un conducto, a través del orificio
de exceso de conducto (13) en el compartimento de
cableado del montaje.
Alinee la bocallave y las ranuras en la placa de montaje
con los tres tornillos de montaje parcialmente instalados y
ajuste los tornillos de montaje para asegurar el montaje.
Use tuercas para conexión de cables para hacer las
conexiones de cableados dentro del compartimento de
cableado tal como se explica en las instrucciones en el
paso 4.
Inserte las conexiones de cables en el compartimento de
montaje y vuelva a instalar el panel de acceso.
IMPORTANT SAFETY
INSTRUCTIONS
IMPORTANTES MESURES
DE SÉCURITÉ
INFORMACIÓN IMPORTANTE
DE SEGURIDAD
To reduce the risk of death, personal injury or prop-
erty damage from fire, electric shock, falling parts,
cuts/abrasions, and other hazards read all warnings
and instructions included with and on the the fixture
box and all fixture labels.
Before installing, servicing, or performing routine
maintenance upon this equipment, follow these general
precautions.
Commercial installation, service and maintenance of
luminaires should be performed by a qualified licensed
electrician.
For Residental installation: If you are unsure about
the installation or maintenance of the luminaires, con-
sult a qualified licensed electrician and check your
local electrical code.
DO NOT INSTALL DAMAGED PRODUCT!
Recycle: For information on how to recycle LED elec-
tronic products, please visit
www.epa.gov.
Fixture can NOT be used with a dimmer switch,
motion or occupancy sensors and other electronic
switching devices unless otherwise designated.
This fixture should not be used in areas with limited
ventilation or high ambient temperatures.
This fixture is intended to be connected to a prop-
erly installed and grounded UL listed junction box.
These instructions do not purport to cover all details
or variations in equipment nor to provide every possible
contingency to meet in connection with installation,
operation, or maintenance. Should further information
be desired or should particular problems arise which
are not covered sufficiently for the purchaser’s or
owner’s purpose, this matter should be referred to Acu-
ity Brands Lighting, Inc.
WARNING:
RISK OF ELECTRICALSHOCK
Turn off electrical power at fuse or circuit breaker box
before wiring fixture to the power supply.
Turn off the power when you perform any maintenance.
Verify that supply voltage is correct by comparing it with
the luminaire label information.
Make all electrical and grounded connections in accor-
dance with the National Electrical Code and any applicable
local code requrirements.
All wiring connections should be capped with UL ap-
proved wire connectors.
CAUTION: RISK OF INJURY
Wear gloves and safety glasses at all times when
removing luminaire from carton,installing, servicing or
performing maintenance.
Avoid direct eye exposure to the light source while it
is on.
Account for small pars and destroy packing material,
as these may be hazardous to children.
WARNING: RISK OF BURN
Allow fixture to cool before handling. Do not touch
enclosure or light source.
Do not exceed maximum wattage marked on luminaire
label.
Follow all lamp manufacturer’s warnings, recommen-
dations and restrictions for: driver type, burning posi-
tion, mounting locations/methods, replacement, and re-
cycling.
Use only lamps that comply with ANSI standards.
CAUTION: RISK OF FIRE
Keep combustible and other materials that can burn
away from luminaire and lamp/lens.
Minimum 75° C supply conductors.
Afin de réduire le risque de blessures personnelles ou
de mort, ou d’endommager le matériel en raison d’un
incendie, d’un choc électrique, de la chute de pièces, de
coupures/abrasions ou de tout autre danger, lisez tous
les avertissements et instructions compris dans et sur la
boîte de la fixation et toutes ses étiquettes.
Avant d’installer, d’entretenir ou de réaliser une
maintenance de routine sur cet équipement, tenez
compte de ces précautions générales.
L’installation commerciale, l’entretien et les
réparations des lampes ne devraient être effectuées
que par un électricien diplômé et qualifié.
Pour les installations résidentielles : Si vous avez
des doutes quant à l’installation ou l’entretien des
lampes, consultez un électricien diplômé et qualifié et
vérifiez votre code de l’électricité local.
•N’INSTALLEZ PAS UN PRODUIT ENDOMMAGÉ !
Recyclage : pour des informations sur la manière de
recycler les produits électroniques à DEL, veuillez vous
rendre sur
www.epa.gov.
Cette fixation ne peut PAS être utilisée avec un
dispositif de gradation, des capteurs de mouvement ou
d’occupation et d’autres dispositifs de commutation
électroniques sauf indication contraire.
Cette fixation ne devrait pas être utilisée dans des
endroits où la ventilation est limitée ou qui présentent
des températures ambiantes élevées.
Cette fixation est conçue pour être connectée à une
boîte de jonction certifiée UL, correctement installée et
mise à la masse.
Ces instructions ne sont pas censée couvrir tous les
détails ou variations de l’équipement ni fournir toutes
les éventualités possibles en ce qui concerne
l’installation, l’utilisation ou l’entretien. Si des informa-
tions supplémentaires devaient s’avérer nécessaires, ou
si des problèmes particuliers se présentent et ne sont
pas suffisamment repris pour l’acheteur ou du
propriétaire, il conviendra de contacter Acuity Brands
Lighting, Inc à ce sujet.
Para reducir el riesgo de muerte, lesiones
personales o daño a la propiedad que pueda surgir
de incendios, choques eléctricos, cortes,
abrasiones, caída de partes y otros peligros lea
todas las advertencias e instrucciones incluidas en
la caja o su interior, además de las etiquetas del
montaje.
Antes de instalar o revisar el equipo, o realizar
mantenimiento de rutina, siga estas precauciones
generales.
La instalación, la revisión y el mantenimiento
comerciales de las luminarias debe ser realizada por
un electricista calificado autorizado.
En el caso de instalaciones residenciales: Si no
está seguro sobre la instalación o el mantenimiento
de las luminarias, consulte a un electricista
calificado autorizado y verifique el código eléctrico
local.
NO INSTALE EL PRODUCTO SI ESTÁ DAÑADO
Reciclado: Para obtener información sobre cómo
reciclar productos electrónicos LED, visite
www.epa.gov.
El montaje NO se puede utilizar con un reductor
de intensidad de luz, sensor de movimiento u
ocupación, u otro dispositivo de conmutación
eléctrico salvo que se especifique lo contrario.
Este montaje no se debe utilizar en áreas con
poca ventilación o alta temperatura ambiente.
Este montaje ha sido diseñado para conectarse a
una caja de unión aprobada por UL debidamente
instalada y puesta a tierra.
Estas instrucciones no pretenden cubrir todos los
detalles o las variaciones de los equipos ni abarcar
todas las posibles eventualidades relacionadas con
la instalación, el funcionamiento o el mantenimiento.
Si necesita más información o surgen problemas
específicos que no están debidamente cubiertos en
la información del producto, remítase a Acuity
Brands Lighting, Inc.
AVERTISSEMENT:
RISQUE DE CHOC ÉLECTRIQUE
Coupez l’alimentation électrique au niveau du fusible
ou du disjoncteur avant de câbler la fixation sur
l’alimentation.
Coupez l’alimentation lorsque vous effectuez tout
travail d’entretien.
Vérifiez que la tension d’alimentation est correcte en
la comparant avec les informations sur l’étiquette de la
lampe.
Réalisez tous les raccordements électriques et de
masse conformément aux exigences du Code national
de l’électricité et de tout code local applicable.
Tous les raccordements câblés doivent être faits
avec des connecteurs de câbles certifiés UL.
ATTENTION: RISQUE DE BLESSURE
Portez des gants et des lunettes de protection en
permanence lorsque vous retirez la lampe du carton et
que vous procédez à l’installation, à l’entretien ou à des
réparations.
Évitez le contact direct des yeux avec la source de
lumière lorsqu’elle est allumée.
Faites attention aux petites pièces et détruisez le
matériel d’emballage car ils pourraient être dangereux
pour les enfants.
AVERTISSEMENT: RISQUE DE
BRÛLURE
Laissez refroidir la fixation avant de la manipuler. Ne
touchez pas l’enceinte ou la source de lumière.
Ne dépassez pas la puissance maximum indiquée sur
l’étiquette de la lampe.
Respectez tous les avertissements,
recommandations et restrictions du fabricant de lampe
pour le circuit d’attaque, la position de fonctionnement,
les méthodes/endroits de montage, le remplacement et
le recyclage.
Utilisez uniquement les lampes qui sont conformes
aux normes ANSI.
ATTENTION: RISQUE D’INCENDIE
Conservez les matériaux combustibles et tout autre
élément pouvant prendre feu à l’écart de la lampe/
lentille.
Conducteurs d’alimentation de 75° C minimum.
ADVERTENCIA:
RIESGO DE CHOQUE ELÉCTRICO
Desconecte la energía eléctrica en el fusible o
disyuntor antes de conectar el montaje a la fuente de
energía.
Desconecte la energía eléctrica cuando realice
operaciones de mantenimiento.
Verifique que el voltaje de alimentación sea
correcto; compárelo con la información de la etiqueta
de la luminaria.
Realice todas las conexiones eléctricas y a tierra en
cumplimiento del Código Eléctrico Nacional y de los
requisitos del código local vigente.
Todas las conexiones de cableado deben cubrirse
con conectores para cable reconocidos y aprobados
por UL.
PRECAUCIÓN: RIESGO DE LESIONES
Use gafas y guantes de protección en todo
momento al retirar la luminaria de la caja, al
instalarla, repararla o realizar operaciones de
mantenimiento.
Una vez encendida la fuente de luz, evite la
exposición directa con los ojos.
Tenga cuidado con las piezas pequeñas y
destruya el material de embalaje, ya que pueden ser
peligrosos si están al alcance de niños.
ADVERTENCIA: RIESGO DE
QEUEMADURAS
Antes de manipular el montaje, déjelo enfriar. No
toque la carcasa ni la fuente de iluminación.
No supere el voltaje máximo señalado en la
etiqueta de la luminaria.
Respete todas las advertencias, recomendaciones
y restricciones que proporciona el fabricante para:
tipo de conductor, posición de funcionamiento,
puntos o métodos de montaje, reemplazo y reciclado.
Use sólo lámparas que cumplan los estándares
ANSI.
PRECAUCIÓN: RIESGO DE INCENDIO
Mantenga lejos de la luminaria y de las lámparas/
lentes, los materiales combustibles y de otro tipo que
se puedan incendiar.
Conductores de alimentación de un mínimo de
75° C.
Page 2
Page 7
CAUTION: RISK OF PRODUCT
DAMAGE
Never connect components under load.
Do not mount or support these fixtures in a
manner that can cut the outer jacket or damage
wire insulation.
Unless individual product specifications deem
otherwise: Never connect an LED product di-
rectly to a dimmer packs, occupancy sensors,
timing devices, or other related control devices.
LED fixtures must be powerd directly off a switch
circuit.
Unless individal product specifications deem oth-
erwise: Do not restrict fixture ventilation. Allow for
some volume of airspce around fixture. Avoid cov-
ering LED fixtures with insulation, foam, or other
material that will prevent convection or conduction
cooling.
Unless individual product specifications deem
otherwise: Do not exceed fixtures maximum am-
bient temperature.
Only use fixture in its intended location.
LED products are Polarity Sensitive. Ensure
proper Polarity before installation.
Electrostatic Discharge (ESD): ESD can
damage LED fixtures. Personal grounding
equipment must be worn during all installation
or servicing of the unit.
Do not touch individual electrical components as
this can cause ESD, shorten lamp life, or alter per-
formance.
Some components inside the fixture may not be
serviceable. In the unlikely event your unit may
require service, stop using the unit immediately and
contact an ABL representative for assistance.
IMPORTANT SAFETY
INSTRUCTIONS
3C.Surface and conduit mounting: see FigC
Use Mounting plate [8] as template to mark mounting hole
locations and drill 3/16” diameter pilot holes. Partially install
Mounting screws (Hardware included for mounting to wood
surfaces only) Note: Assure that fixture is mounted onto
structurally sound surface that will support the weight of
the fixture.
Remove access panel [14] Note: a safety tether will
temporarily hold the panel. Thread house supply wires
through Mounting plate and fixture neck or, if conduit is
used, through Conduit excess hole (13) into fixture wiring
compartment.
Align keyhole and slots on Mounting Plate with the three
partially installed Mounting Screws and tighten the Mount
ing Screws to secure fixture.
Use wire nuts to make wiring connections inside wiring
compartment as outlined in instructions in step 4.
Push wire connections into fixture compartment and
re-install access panel.
INSTALLATION INSTRUCTIONS
4. CAUTION: WIRING AND FIXTURE OPERATION Note: Make sure power is turned off!
Use Wire Nut to connect the house supply ground wire (copper) & the fixture ground (copper) wire.
Note: If house wiring does not include a ground wire, consult your local electrical code for approved grounding methods.
Use Wire Nuts to connect the black fixture wire to theblack power supply wire and the white fixture wire to the white
(neutral) house supply wire.
For proper connection, place wire nut over wires
and twist clockwise until tight.
5. Turn on electricity at fuse or circuit breaker box and verify success of installation.
Note: Adjust photocontol so that the window is fully open
6. Apply silicone caulking (not included) around the perimeter of the back of the
fixture where it contacts the mounting surface for moisture seal.
This LED light provides low maintenance service with no bulbs to change. Clean surfaces with mild soap and water. Do not
use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.
WARNING: There are no user serviceable parts inside fixture.
Fig C
6) 1/2” Screw
8) Mounting Plate
1) LED Light Fixture
7) Gasket
12) Safety
Tether
13) Conduit
access Cap
14) access panel
INSTALLATION FIGURES - FIGURES D’INSTALLATION
FIGURAS DE LA INSTALACIÓN
Failure to follow any of these instructions
could void product warranties. For a
complete list of product Terms and Condi-
tions, visit www.acuitybrands.com. Acuity
Brands Lighting, Inc. assumes no responsi-
bilities for claims arising out of improper or
careless installation or handling of its
products.
Tout manquement au respect de ces
instructions pourrait rendre nulles les
garanties. Pour une liste complète des
conditions générales du produit, veuillez vous
rendre sur www.acuitybrands.com. Acuity
Brands Lighting, Inc. n’assume aucune
responsabilité pour les réclamations
découlant d’une installation ou d’une manipu-
lation incorrectes ou négligentes de ses
produits.
El incumplimiento de alguna de estas
instrucciones puede anular la garantía del
producto. Para obtener la lista completa de
los términos y las condiciones respecto al
producto, visite www.acuitybrands.com.
Acuity Brands Lighting, Inc. no se hace
responsable por los reclamos que puedan
surgir de la instalación o manipulación
inadecuada o negligente de sus productos.
IMPORTANTES MESURES
DE SÉCURITÉ
INFORMACIÓN IMPORTANTE
DE SEGURIDAD
Page 6
Page 3
Cet équipement a été examiné et avéré pour
être conforme aux limites pour un dispositif de la
classe B digital, conformément à la partie 15 des
règles de FCC. Ces limites sont conçues pour
assurer la protection raisonnable contre
l’interférence nocive une fois utilisées dans un
environnement commercial. Cet équipement se
produit, des utilisations et peut rayonner l’énergie
de radiofréquence. Sinon installé et utilisé selon
le manuel d’instruction, cet équipement peut
causer l’interférence nocive aux communications
par radio. L’opération est sujette aux deux condi-
tions suivantes :
1) Ce dispositif peut ne pas causer
l’interférence nocive, et.
2) Ce dispositif doit accepter n’importe quelle
interférence reçue, y compris l’interférence
qu’opération peu désirée de cause de mai.
Este equipo se ha probado y se ha encontrado
para conformarse con los límites para un
dispositivo de la clase B digital, conforme a la
parte 15 de las reglas de la FCC. Estos límites
se diseñan para proporcionar la protección
razonable contra interferencia dañosa cuando
están utilizados en un ambiente comercial. Este
equipo genera, las aplicaciones y puede irradiar
energía de la radiofrecuencia. Si no instalado y
utilizado de acuerdo con el manual de la
instrucción, este equipo puede causar
interferencia dañosa a las comuncaciones por
radio. La operación está conforme a las dos
condiciones siguientes:
1) Este dispositivo puede no causar
interferencia dañosa,y
2) Este dispositivo debe aceptar cualquier
interferencia recibida, incluyendo interferencia
que operación indeseada de la causa de
mayo.
This equipment has been tested and found to
comply with the limits for a class B digital
device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reason-
able protection against harmful interference
when used in a commercial environment. This
equipment generates, uses and can radiate
radio frequency energy. If not installed and
used in accordance with the instruction
manual, this equipment may cause harmful
interference to radio communications.
Operation is subject to the following two
conditions:
1) This device may not cause harmful
interference, and
2) This device must accept any interference
received, including interference that may cause
undesired operation.
PRECAUCIÓN: RIESGO DE DAÑO
PARA EL PRODUCTO
Jamás conecte componentes bajo carga.
No monte estos montajes de manera que
puedan cortar el revestimiento exterior o dañar
el aislamiento de los cables.
A menos que las especificaciones del
producto individual consideren lo contrario:
jamás conecte un producto LED directamente
a un paquete de reducción de intensidad de la
luz, sensores de ocupación, dispositivos de
temporización ni demás dispositivos de con-
trol relacionados. Los montajes LED se deben
apagar directamente de un circuito de
interruptores.
A menos que las especificaciones del
producto individual consideren lo contrario: no
limite la ventilación del montaje. Deje un poco
de espacio alrededor del montaje. Evite cubrir
los montajes LED con aislación, goma u otro
material que evitará la convección o el
enfriamiento de la conducción.
A menos que las especificaciones del
producto individual consideren lo contrario: no
supere la temperatura ambiente máxima para
el montaje.
Use el montaje sólo en la ubicación para la
que está diseñado.
Los productos LED son sensibles a la
polaridad. Asegure la correcta polaridad an-
tes de la instalación.
Descarga electrostática (DES): la DES
puede dañar los montajes LED. Durante la
instalación o reparación de la unidad se
debe usar siempre equipo personal
conectado a tierra.
No toque componentes eléctricos
individuales ya que esto puede causar DES,
reducir la vida útil de la lámpara o alterar el
funcionamiento.
• Es posible que algunos componentes dentro
del montaje no se puedan reparar. En el caso
improbable de que su unidad requiera
reparación, deje de usar la unidad
inmediatamente y comuníquese con un
representante de ABL para obtener ayuda.
ATTENTION : RISQUE
D’ENDOMMAGEMENT DU PRODUIT
Ne connectez jamais des composants sous
charge.
• Ne montez ni soutenez pas ces fixations
d’une manière qui pourrait sectionner la gaine
extérieure ou endommager l’isolation de câble.
Sauf si contraire aux spécifications du
produit individuel : ne connectez jamais un
produit à DEL directement à des packs de
gradation de la lumière, des capteurs
d’occupation, des dispositifs de minuterie ou
d’autres dispositifs de commande liés. Les fixa-
tions DEL doivent être alimentées directement
hors d’un circuit à interrupteur.
Sauf si contraire aux spécifications du
produit individual : Sauf si contraire aux
spécifications du produit individuel : ne pas
limiter la ventilation de la fixation. Laissez un
espace libre suffisant autour de la fixation.
Évitez de couvrir les fixations DEL avec de
l’isolation, de la mousse ou d’autres matériaux
qui empêcheront le refroidissement de con-
vection ou de conduction.
Sauf si contraire aux spécifications du
produit individuel : ne pas dépasser la
température ambiante maximum à laquelle les
fixations sont exposées.
N’utilisez la fixation que dans l’emplacement
prévu à cet effet.
• Les produits à DEL sont sensibles à la polarité.
Assurez-vous que la polarité est correcte
avant l’installation.
Décharge électrostatique (DES) : les DES
peuvent endommager les fixations DEL. Un
équipement de mise à la masse personnel
doit être porté lors de toute installation ou
entretien de l’unité.
Ne touchez pas les composants électriques
individuels car cela peut causer une DES,
réduire la durée de vie de la lampe ou altérer
ses performances.
• Certains composants à l’intérieur de la
fixation peuvent ne pas être réparables.
Dans le cas peut probable où votre unité
aurait besoin d’être réparée, arrêtez
immédiatement d’utiliser l’unité et contactez
un représentant ABL pour obtenir de l’aide.
15) photocontrol
GUÍA DE PASO-A-PASO
LISTA DE EMBALAJE
Descripción Cantidad
1) Montaje de luz LED........................................................................1
2) Barra transversal*.........................................................................1
3) Conducto roscado*.......................................................................1
4) Tornillos n.º 8 de 1/2"*....................................................................2
5) Placa posterior*.............................................................................1
6) Tornillos N.º 8 de 1/2*(acero inoxidable) ...............................................4
7) Junta* ..............................................................................................1
8) Placa de montaje*...........................................................................1
9) Tuercas para conexión de cables* ...................................................3
10) Tuercas decorativas*.......................................................................1
11) Tornillos de sujeción .......................................................................2
12) Amarre de seguridad ......................................................................1
13) Válvula de acceso de conductos ...................................................1
14) Panel de acceso ............................................................................1
15) Control fotográfico ajustable ............................................................1
16) Llave Allen* .....................................................................................1
*Incluidos en los paquetes de piezas
Herraje de Montaje Incluido
Requiere Sellador de Silicona
1. Quite los componentes del luminario y el paquete de
piezas. Verifique que todas las piezas estén incluidas.
2. ¡Apague la electricidad en la caja de rtacircuitos!
ATENCIÓN: No se confie de cortar la corriente en el
interruptor mural solamente.
Nota: Este montaje NO se puede usar con reductores de
lumbrado, sensores de movimiento u otros dispositivos
remotos.
Nota: Este montaje es para montaje de pared sobre 6 pies (1.8
m) únicamente. NO LO USE COMO LÁMPARA DE TECHO
Este montaje ha sido diseñado para permitir diferentes
formas de instalación:
3A. Instalación a la caja de unión redonda o rectangular
empotrada y redonda de montaje de superficie: ver Fig. A1
y A2
Retire la placa de montaje [8] (mostrada en la Fig. B) y conecte
la placa posterior [5] (ver Fig. A1).
Instale la barra transversal (2) con conducto roscado (3) en la
caja de unión empotrada estándar para lugares húmedos de
exteriores utilizando dos tornillos de 1/2" (4) (ver Fig. A2).
Use tuercas para conexión de cables (9) para hacer las
conexiones de cableado tal como se explica en el paso 4.
Coloque las conexiones de cable en la caja de unión y alinee
la placa posterior con el conducto roscado. Lleve la placa
posterior cerca de la pared y asegure con tornillo decorativo
(10) Nota: Asegúrese de no apretar ningún cable.
GUIDE DÉTAILLÉ
LISTE DES PIÈCES
Description Quantité
1) Appareil d’éclairage DEL ..................................................................1
2) Barre transversale*........................................................................ 1
3) Tuyau fileté* .....................................................................................1
4) Vis de 1/2 po*....................................................................................2
5) Plaque arrière* ..................................................................................1
6) Vis nº 8 de 1/2 po *(acier inoxydable) ..................................................... 4
7) Joint* .................................................................................................1
8) Plaque de montage* .........................................................................1
9) Capuchons de connexion* .................................................................3
10) Écrous décoratifs* ............................................................................1
11)Vis de calage ....................................................................................2
12) Câble de sécurité .............................................................................1
13) Capuchon d’accès au conduit..........................................................1
14) Panneau d’accès .............................................................................1
15) Photocontrôle réglable .................................................................... 1
16) Clé Allen* ......................................................................................... 1
*Compris dans l’emballage de pièces
Quincaillerie de montage comprises
Joint d’étanchéité à la silicone requis
1. Retirer les composants de l’appareil et l’emballage des
pièces. S’assurer que toutes les pièces sont incluses.
2. Couper l’électricité au fusible ou au disjoncteur!
ATTENTION: Ne coupez pas le courant uniquement
au niveau de l’interrupteur mural.
Remarque: Cette fixation n’est pas compatible avec les
gradateurs ou les dispositifs de gradation de la lumière.
L’appareil est conçu pour montage mural à au moins pi du sol
seulement.
Remarque : Cette fixation est prévue pour un montage mural
au-dessus de 6 pi (1.8m) uniquement - NE PAS UTILISER
COMME ÉCLAIRAGE VERS LE HAUT
Cette fixation a été conçue pour être montée de différentes
manières.
3A. Installation sur boîte de jonction ronde ou rectangulaire
encastrée et montage sur surface ronde: voir Fig. A1 et A2
Retirez la plaque de montage [8] (illustrée à la Fig B) et
attachez la plaque arrière [5] (voir Fig A1).
Installez la barre transversale [2] avec le tuyau fileté [3] sur la
boîte de jonction en emplacement humide extérieur, à
encastrement standard, en utilisant deux vis de 1/2 po [4] (voir
Fig A2).
Utilisez les capuchons de connexion [9] pour réaliser les
connexions de câblage comme indiqué à l’étape 4.
Poussez les connexions de câbles dans la boîte de jonction et
alignez la plaque arrière avec le tuyau fileté. Approchez la
plaque arrière du mur en la poussant et fixez avec un écrou
décoratif [10] Remarque : assurez-vous de ne pincer aucun
câble.
3B. Installation sur bras d’extension (vendu séparément):
voir Fig. B
Desserrez les vis de calage [11] au bas du collier de la fixation
et retirez le panneau d’accès [14] (voir Fig C) de la fixation
d’éclairage à DEL afin d’accéder au compartiment de câblage.
Remarque : un câble de sécurité maintiendra temporairement
le panneau lors du câblage de la fixation.
Alignez le trou du collier de la fixation d’éclairage à DEL avec
le bras d’extension, faites passer les câbles d’alimentation de
la maison s’étendant du bras à travers le collier et dans le
compartiment de câblage de la fixation, puis glissez la fixation
d’éclairage à DEL sur le bras en faisant attention à ne pas
pincer de câble. Assurez-vous que la fixation est droite et serrez
les vis de calage pour fixer. Suivez les instructions de câblage
de la fixation contenues dans cette feuille d’installation, à
l’étape 4.
3B. Instalación a brazo de extensión (se vende por
separado): ver Fig. B
Afloje los tornillos de sujeción (11) en la parte inferior del
collarín de montaje y retire el panel de acceso (14) (ver Fig. C)
del montaje para lámparas LED para acceder al
compartimento de cableado. Nota: Un amarre de seguridad
sostendrá temporalmente el panel al cablear el montaje.
Alinee el orificio en el collarín del montaje para lámpara LED
con el brazo de extensión, coloque los cables de suministro
extendiendo desde el brazo hasta el collarín en el
compartimento de cableado del montaje y deslice el montaje
para lámpara LED en el brazo con cuidado de no apretar
ningún cable. Asegúrese de que el montaje esté nivelado y
ajuste los tornillos de fijación para asegurar. Siga las
instrucciones de cableado del montaje contenidas en esta
Hoja de instrucciones en el Paso 4.
FIXTURE PACKING LIST
Description Quantity
1) LED Light Fixture................................... ....................... 1
2) Crossbar* ......................................................................... 1
3) Threaded Pipe* ................................................................. 1
4) 1/2" #8 Screws* ................................................................ 2
5) Backplate* ........................................................................ 1
6) 1/2” #8 Screws *(stainless steel)...................................... 4
7) Gasket* ............................................................................ 1
8) Mounting Plate* ................................................................ 1
9) Wire Nuts* ........................................................................ 3
10) Decorative Nut* ................................................................ 1
11) Set Screws ...................................................................... 2
12) Safety Tether ................................................................... 1
13) Conduit access Cap............................. ........................ 1
14) Access Panel.................................. ............................. 1
15) Adjustable Photocontrol................................... ............ 1
16) Allen Wrench*............................................................... 1
*Contained in parts packs
Mounting Hardware Included
Silicone Sealant required
INSTALLATION INSTRUCTIONS
1. Remove fixture components and parts pack. Check that
all parts are included.
2. Turn OFF Power at circuit breaker box.
CAUTION: Do not rely on wall switch alone to turn off power.
Note: NOT suitable for use with dimmers, motion sensors
or other remote devices.
Note: This Fixture is intended for Wall mount above
6ft (1.8m) only - DO NOT USE AS UPLIGHT
This fixture is designed for multiple installation options:
3A. Installation to round or rectangular recessed and
round surface mount j-box: see FigA1 & A2
Remove Mounting Plate [8] (shown in Fig B) and attach
Backplate [5] (see Fig A1).
Install Crossbar [2] with Threaded Pipe [3] to standard
recessed outdoor wet location junction box using two 1/2”
screws [4] (see Fig A2).
Use wire nuts [9] to make wiring connections as outlined in
step 4.
Push wire connections into j-box and align Backplate with
the Threaded Pipe. Push Backplate close up to wall and
secure with Decorative Nut [10] Note: make sure not to
pinch any wires.
REQUIRED TOOLS
HERRAMIENTAS REQUERIDAS
OUTILS REQUIS
6) 1/2” Screws
1) LED Light Fixture
5) Backplate
7) Gasket
Fig A1
Fig A2
10) Decorative Nut
2) Crossbar
9) Wire
Nuts
4) 1/2” Screws
3) Threaded Pipe
INSTALLATION FIGURES/FIGURES D’INSTALLATION
FIGURAS DE LA INSTALACIÓN
3B. Installation to extension arm (sold separately): See FigB
Loosen Set Screws [11] on bottom of fixture neck (with
included allen wrench) and remove access panel [14] (see
FigC) of LED Light Fixture to access wiring compartment.
Note: a safety tether will temporarily hold the panel while
wiring fixture.
Align hole in neck of LED Light Fixture with extension arm,
thread house supply wires extending from arm through
neck into fixture wiring compartment and slide LED Light
Fixture onto arm being careful not to pinch any wires.
Make sure fixture is level and tighten Set Screws to
secure. Follow fixture wiring instructions contained in this
Inst Sheet in step 4.
Fig B
Mounting Arm
(sold separately)
11) Set Screw
14) access panel
Page 5
Page 4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Lithonia Lighting OLAW23 53K 120 PE BZ Guide d'installation

Taper
Guide d'installation