p.
- Manual code:
FA00040-EN v.
- 04/2015 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
ORDINARY MAINTENANCE GUIDE
FOR SERIES BX, BX-243, BK and BY-3500T OPERATORS
This document provides fi tters with indications on which obligatory checks to make when performing maintenance jobs.
• Every 10,000 cycles and, anyhow, every six months:
1. Perform a general and complete check on the the tightness of the nuts and bolts.
2. Check linearity and cleanliness of the guide and rack along the entire length of the gate.
3. Lubricate all moving mechanical parts: castors, slide wheels, and so on, and check the state of wear and tear and proper functioning.
4. Check the e ciency of the locking mechanism and perform a maneuver, to see whether there are any obstructions.
5. Check the proper working state of all of the system's command and control and safety devices.
6. Check the integrity of the cables and their connections.
Important:
With installations in windy areas, reduce the MCBF value by 15%.
If the system is unused for long periods, such as when fi tted in seasonally opened locations, you should cut o the main power supply, and
perform all of the mentioned checks when restoring the system for use.
Evaluating the type and frequency of jobs must always be done by a professional fi tter, according to the use, place of installation and the
estimated daily cycles fi gure, which may require fi tting a maneuver counter device.
For all other information about proper installation, adjustments and ordinary maintenance, read the installation manual. For all information about
product and corresponding accessory choice, browse the products catalog.