N C
M Y
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES: If the distance “A” between the wall cabinets is between 600 mm. and 680 mm. the
height “B” must be a minimum of 520 mm. If the distance “A” between the wall cabinets is
greater than the width of the Cooktop, the height “B” must be a minimum of 400 mm.
INJECTORS TABLE CATEGORY II 2H 3+
Type of gas Type of Injector Rated heat Rated Reduced
used burner marking capacity consump- heat
Gas pressure
tion capacity
Pcs-kW Pcs-kW min. rat. max.
NATURAL large 130 3,00 286 l/h 0,80
GAS medium 105 1,75 167 l/h 0,50 17 20 25
(Methane) G 20 small 83 1,00 95 l/h 0,50
LIQUID large 85 3,00 218 g/h 0,80
PETROLEUM GAS medium 65 1,75 127 g/h 0,50 20 28-30 35
(Cylinder) G 30 small 50 1,00 73 g/h 0,50
LIQUID large 85 3,00 214 g/h 0,80
PETROLEUM GAS medium 65 1,75 125 g/h 0,50 25 37 45
(Cylinder) G 31 small 50 1,00 71 g/h 0,50
Type of gas Appliance Total rated Total rated Air required
used model heat capacity consumption for burning
Pcs-kW m
3
/h
G20 20 mbar 5 gas 10,5 1000 l/h 21
G30 28-30 mbar 5 gas 10,5 764 g/h 21
G31 37 mbar 5 gas 10,5 750 g/h 21
82547 GB 6