DMP Electronics 1116 Relay Output Guide d'installation

Catégorie
Émetteurs muraux
Taper
Guide d'installation

Ce manuel convient également à

1116 WIRELESS RELAY OUTPUT
Installation Guide
DESCRIPTION
The 1116 Wireless Relay Output
provides a Form C (SPDT) dry
relay contact rated for 1 Amp at 30
VDC. Regardless of the state of the
relay, the 1116 operates on constant
minimal standby current. The 1116
relay can be controlled from a
DMP panel output programmed to
respond to a variety of conditions
such as armed area annunciation,
ambush alarm, burglary alarm, exit
timer, entry timer, schedules, or
communication failure.
Compatibility
All DMP 1100 Series Wireless
Receivers and burglary panels
What is Included?
1116 Wireless Relay Output
3 V Lithium CR123A battery
Hardware pack
1PROGRAM THE PANEL
Refer to the panel programming guide as needed.
1. In OUTPUT INFO or OUTPUT SETUP, enter the OUTPUT
number.
2. Enter the OUTPUT NAME.
3. Enter the eight-digit SERIAL# and press CMD.
4. Enter the SUPRVSN TIME and press CMD.
5. Press the back arrow when OUTPUT NO: displays.
6. Press CMD until STOP displays and then press any select
area to save and exit programming.
Note: For wireless output troubles to display at a keypad on
an XR150/XR550 Series system, the keypad address must be
specified at the AUX 1 ZONES (Auxiliary 1 Zones) option in
the Status List programming menu. See the XR150/XR550
Programming Guide (LT-1232) for more information.
Program Slow Response
Use the following output numbers for your device to indicate whether
the wireless device responds within 15 seconds to trip the output
(slow response). Programming the 1116 as a slow response output can
increase battery life. See last page for battery life expectancy.
Panel Output numbers
XTLplus (LT-1434) 51-54
XTLtouch (LT-1789) 51-54
XR150/XR550 (LT-1232) 450-474
XT30/XT50 (LT-0981) 31-34
Program Fast Response
Use the following output numbers for your device to indicate whether
the wireless device responds within 1 second to trip the output (fast
response). Programming the 1116 as a fast response output can
decrease battery life. See last page for battery life expectancy.
Panel Output numbers
XTLplus (LT-1434) 61-64
XTLtouch (LT-1789) 61-64
XR150/XR550 (LT-1232) 480-499
XT30/XT50 (LT-0981) 41-44
Supervision Reset
Supervision time is reset under the following circumstances:
A receiver is installed, powered down, and powered up.
The panel is reset.
Programming is complete.
Note: If the receiver has been powered down for more than
one hour, the device may take up to an additional hour to
send a supervision message unless tripped, tampered, or
powered up. This operation extends battery life. A missing
message may display on the keypad until the supervision
message is sent.
Figure 1: 1116
2 1116 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS
3The 1116 Wireless Relay Output provides a Survey LED capability to allow one person to confirm
communication with the wireless receiver or panel while the cover is removed.
1. With the cover removed, hold the device in the exact desired location.
2. Press the tamper switch to send data to the panel and determine if communication is confirmed or
faulty.
Confirmed: If communication is confirmed, for each press or release of the tamper switch, the LED
blinks immediately on and immediately o. Repeat this test to confirm five separate consecutive LED
blinks. Any indication otherwise means proper communication has not been established.
Faulty: If communication is faulty, the LED remains on for about 8 seconds or flashes multiple times
in quick succession. Relocate the device or receiver until the LED confirms clear communication.
SELECT A LOCATION
POWER THE DEVICE
2Power the device with a 3V lithium battery or a 12VDC power supply. Do not install a battery if the device is
being powered by a power supply. The power supply does not charge the battery.
CR123A 3V Lithium Battery
Observe polarity when installing the included CR123A
battery.
1. Remove the housing cover.
2. Install the supplied jumper on the two pins next
to BAT on the power source header.
3. Place the battery in the holder and observe
polarity.
4. Snap the cover back into place.
12VDC Plug-In or External Power Supply
The device can also be powered by a 12VDC plug-in
power supply (e.g. DMP Model 376L) or a 12VDC external
power supply (e.g. DMP Model 505-12). When using a plug-in
power supply, mount the device near a wall outlet.
1. Remove the housing cover.
2. Install the supplied jumper on the two pins next to EXT on
the power source header.
3. Wire the power supply to the DC power terminals by
following the power supply-specific instructions below.
Plug-In Power Supply
Connect the black wire with the white stripe to the positive (+)
terminal and the solid black wire to the negative (-) terminal. See
Figure2. Plug the power supply into a 110VAC outlet.
External Power Supply
Using 22AWG wire, connect the DC power terminal block on the
device to the DC power terminal on the 505-12 power supply PCB.
Observe positive and negative polarity on all connections. See
Figure3.
Snap the cover back into place when you are finished.
Figure 2: PCB Side View
Figure 3: Power Supply Connection
+ DC -
505-12 Power
Supply
12 VDC
22 AWG
Wire
DC Power
2-position
Terminal Block
- +
- +
DC
Plug-in
Power
Supply
DC Power
2-position
Terminal Block
- +
- +
Black Wire
with White
Stripe
to Positive
Black Wire
to
Negative
1116 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS 3
MOUNT THE DEVICE
Mount the device on a flat surface such as a wall or single-gang box. When using the optional Model 376L
plug-in power supply, mount the device near a wall outlet. See Figure4 for an example of all mounting holes
on the housing base. Use any combination.
4
5CONNECT THE DEVICE
Use 22 or 18 AWG wire to connect the relay output. The Form
C relay can be connected to operate as Normally Closed
(NC) or Normally Open (NO). See Figure 5.
ADDITIONAL INFORMATION
1116 Relay Output Annunciation
The following table shows the device annunciation operation options.
Panel Programmed Action Annunciation
STEADY Relay output turns on and remains on
PULSE Relay output alternates one second on, one second o
MOMENTARY Relay output turns on once for one second
TEMPORAL (XR150/XR550 SERIES ONLY) Relay output repeats the following sequence:
on 1/2 second, o 1/2 second
on 1/2 second, o 1/2 second
on 1/2 second, o 1-1/2 second
Figure 4: Mounting Hole Locations
Mounting Hole
Figure 5: Relay Connection
Designed, engineered, and
manufactured in Springfield, MO
using U.S. and global components.
LT-0707 20361
1116 WIRELESS RELAY
OUTPUT
Specifications
Battery
Life Expectancy 2 months (fast response)
5 years (slow response)
Type 3 V Lithium CR123A
Frequency Range 905-924 MHz
Dimensions 4.65” L x 3.10” W x 1.40” H
11.81 L x 7.87 W x 3.56 H cm
Color White
Housing Material Flame Retardant ABS
Accessories
CR123 DMP 3 V Lithium Battery
376L DC Plug-in Power Supply
505-12 12 VDC Power Supply
Compatibility
XT30 panels with 1100D Series Wireless Receiver with Version
105 or higher
XT50 panels with integrated wireless receiver or 1100D Series
Wireless Receiver with Version 105 or higher
XR150/XR550 Series panels with 1100X Series Wireless
Receivers with Version 105 or higher
XTLplus panels with integrated wireless receiver
XTLtouch panels with integrated wireless receiver
Patents
U.S. Patent No. 7,239,236
Certifications
FCC Part 15 Registration ID CCKPC0101
IC Registration ID 5251A-PC0101
INTRUSION FIRE ACCESS NETWORKS
2500 North Partnership Boulevard
Springfield, Missouri 65803-8877
800.641.4282 | DMP.com
FCC INFORMATION
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause undesired operation.
The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.874 in.) from
all persons. It must not be located or operated in conjunction with any other antenna or transmitter.
Changes or modifications made by the user and not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment o and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for help.
INDUSTRY CANADA INFORMATION
This device complies with Industry Canada Licence-exempt RSS standards. Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. this device must accept any interference, including interference that may cause undesired operation of the device.
This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health Canada Safety
Code 6. The system must be installed at a minimum separation distance from the antenna to a general bystander of 7.87 inches (20 cm)
to maintain compliance with the General Population limits.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. Lexploitation est
autorisée aux deux conditions suivantes:
1. l’appareil ne doit pas produire de brouillage, et
2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
Lexposition aux radiofréquences de ce système a été évaluée selon la norme RSS-102 et est jugée conforme aux limites établies par le
Code de sécurité 6 de Santé Canada. Le système doit être installé à une distance minimale de 7.87 pouces (20 cm) séparant l’antenne
d’une personne présente en conformité avec les limites permises d’exposition du grand public.
© 2020
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

DMP Electronics 1116 Relay Output Guide d'installation

Catégorie
Émetteurs muraux
Taper
Guide d'installation
Ce manuel convient également à