Regency Skope E110 Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire

Ce manuel convient également à

919-922 (April 2019)
Instructions for Use, Installation & Servicing
For use in US and CA.
Consignes d’installation et d’utilisation
À utiliser aux É-U et au CA.
IMPORTANT
THE HEATER OUTLET GRILLE BECOMES VERY HOT
WHILE IN OPERATION.
DO NOT COVER THE OUTLET GRILLE OR ANY PART OF
THE APPLIANCE.
For use with 120V 60Hz electricity supply only.
Please read these instructions carefully before installation.
Failure to follow them could result in serious injury.
SAVE THESE INSTRUCTIONS: Leave this manual with the appliance,
they will be needed when maintenance or servicing is required.
THIS APPLIANCE MUST BE GROUNDED
IMPORTANT
LA GRILLE D'ÉVACUATION DU SYSTÈME DE CHAUFFAGE
DEVIENT TRÈS CHAUDE LORS DU FONCTIONNEMENT.
NE PAS COUVRIR LA GRILLE D'ÉVACUATION NI TOUTE
AUTRE PARTIE DE L'APPAREIL.
Pour utilisation uniquement avec une alimentation électrique de 120V,
60Hz.
Veuillez lire ces instructions avec attention avant de procéder à
l’installation.
Ne pas les suivre pourrait entraîner des blessures graves.
CONSERVEZ CES INSTRUCTIONS: Laissez ce manuel avec l'appareil, ils
seront nécessaires lorsque l'entretien ou l'entretien est nécessaire.
CET APPAREIL DOIT ÊTRE RELIÉ À LA TERRE
Skope Multi -Sided Electric LED Fireplace
Cheminée à LED murale multifaces Skope
Model/ modèle:
E110
2
User Instructions...................................................3
1. Important Information & Health and Safety........................3
2. Operating Instructions........................................................4
3. Maintenance.......................................................................9
Installation Instructions........................................11
Technical Specifications.........................................................11
Appliance Dimensions............................................................11
Installation..............................................................12
1. General...............................................................................12
2. Fitting the Appliance...........................................................12
3. Wiring Kits...........................................................................13
4. Mounting Bracket................................................................15
5. Custom Built Installation.....................................................15
6. Corner Installation (if applicable)........................................20
7. Removing the Exterior Glass..............................................24
8. Fuel Effect............................................................................24
9. Completion of Assembly......................................................26
Servicing.................................................................27
1. Fault Finding........................................................................27
2. Servicing Requirements......................................................27
3. Removing the Exterior Glass..............................................27
4. Removing the LED Light Bar..............................................28
5. Removing the Fuel Bed.......................................................29
6. Replacing the Fuel Bed Effects Spindle.............................29
7. Replacing the Fuel Bed LED Boards..................................30
8. Replacing the Interior Glass................................................30
9. Replacing the Effects Screen..............................................31
10. Replacing the Flame Effects Spindle................................32
11. Replacing the Flame Effects LED Board..........................32
12. Replacing the Fuel Bed Motor..........................................33
13. Replacing the Flame Effects Motor..................................33
14. Replacing the Power Unit.................................................34
15. Replacing the Heater Assembly.......................................34
16. Pairing the Remote Control to the Appliance...................35
17. Resetting the Remote Control..........................................35
Wiring Diagram......................................................36
Packing Checklist.................................................37
Spare Parts List.....................................................38
Contents
Covering the following models:
Recycle in accordance with Code of
Federal Regulations (CFR), Title 40, Part
273. This device is classied as electrical
and electronic equipment
As such, it must not be disposed of with
household waste.
At the end of its useful life please take
this product to an appropriate recycling
center or collection point. You can nd
your nearest recycling drop off point
by contacting your locality’s waste
management ofce.
Safety Alert Key:
WARNING! Indicates a hazardous situation
which, if not avoided could result in death or
serious injury.
CAUTION! Indicates a hazardous situation which,
if not avoided, could result in minor or moderate
injury.
ENGLISH
Warranty
This product carries a 1 year warranty.
Please note that all warranties are effective from the date of
purchase.
Full terms and conditions are detailed in the Warranty Statement
on the Regency website www.regency-fire.com. In the event
of any conflict of information the wording on the website shall
prevail.
Important Note: Should any problems be experienced with your
product, claims must first be submitted to the Dealer where
the appliance was purchased from who will offer immediate
assistance or contact Regency on your behalf.
210-195 Skope E110 Multi Sided Electric Fireplace (43"/1100 mm)
Important : The hand-held transmitter is configured in the factory
with a unique signal code. The hand-held transmitter is ready for
use once the 2 AA batteries are installed.
If the handset loses it signal or needs to be replaced, see section
17 in the servicing section for details.
3
1. IMPORTANT
INFORMATION AND HEALTH
AND SAFETY
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional
information, consult a qualified installer.
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock,
and injury to persons, including the following:
1.1 Read all instructions before using this appliance.
1.2 Use this appliance only as described in this
manual. Any other use not recommended by the
manufacturer may cause fire, electric shock, or
injury to persons.
1.3 DO NOT use outdoors.
1.4 NEVER use this appliance in bathrooms, laundry
rooms, or any other location where the appliance
could fall into a bathtub or pool, become damp, or
come in contact with water.
1.5 For residential use only. NOT for commercial use!
Any commercial or public use of this appliance voids
all warranties, and could cause injury.
1.6 This product is not intended to be a primary heat
source. It is for supplemental heat only.
1.7 Do not locate the appliance immediately below a fixed
receptacle outlet.
Electrical Supply Circuit Requirements
Plan the location of the appliance so that it will have
adequate electric power. A 15 AMP, 60Hz circuit is
required for 120V installation. Additional appliances
on the same circuit as this appliance may exceed the
current rating of that circuit. A dedicated circuit is not
required, but is preferred to prevent circuit breaker trips
or fuse failure.
1.8 This appliance must be grounded.
1.9 DO NOT operate any appliance with a damaged cord
or plug or after the appliance malfunctions, has
been dropped or damaged in any manner. Discard
appliance, or return to authorized service facility for
examination and/or repair.
1.10 This appliance is hot when in use. To avoid burns,
DO NOT let bare skin touch hot surfaces. Keep
combustible materials, such as furniture, pillows,
bedding, papers, clothes, and curtains at least 3 feet
(0.9m) from the front of the appliance.
1.11 Extreme caution is necessary when any appliance is
used by or near children or invalids and whenever
the appliance is left operating and unattended.
User Instructions
1.12 DO NOT insert or allow foreign objects to enter any
ventilation or exhaust opening, as this may cause
electric shock or fire, or damage the appliance.
1.13 To prevent a possible fire, DO NOT block air intakes
or exhaust in any manner. Doing so could cause a
fire. DO NOT use on soft surfaces, like a bed, where
openings may become blocked.
1.14 As the appliance has hot and arcing or sparking
parts inside, DO NOT use it in areas where gasoline,
paint, or flammable liquids are used or stored.
1.15 AVOID FIRE! Regularly inspect all air vents to make
sure they are free from dust, lint, or other blockage.
Unplug the unit and clean with a vacuum ONLY. DO
NOT rinse or get wet.
1.16 DO NOT USE this appliance with any solid state
speed control devices.
1.17 Risk of electric shock! DO NOT OPEN! No user-
serviceable parts inside!
1.18 NEVER modify this appliance. Doing so could result
in personal injury or property damage. Modification of
this fireplace completely voids all warranties.
1.19 NEVER leave this appliance unattended. To
disconnect appliance, ALWAYS turn controls to
“OFF” then remove plug from outlet or turn off circuit
when not in use.
1.20 ALWAYS turn this appliance off before unplugging it
from the outlet.
1.21 To prevent a possible fire, do not burn wood or other
materials in this appliance.
1.22 ALWAYS disconnect this unit from the power supply
before performing any assembly or cleaning, or before
relocating the electric fireplace.
1.23 Always use properly grounded, fused and polarized
outlets.
1.24 Always use ground fault protection where required
by electrical code.
1.25 Avoid use of another extension cord (besides the
one supplied with this appliance) because an extension
cord may overheat and cause a fire. If you have to
use an extension cord, the cord should be N.14 AWG
minimum size and rated to not less than 1875watts.
1.26 NEVER plug this appliance into an outlet that is old,
cracked, or has any loose wires or connections.
Plugging this appliance into a faulty outlet could result
in electric arcing within the outlet that could cause the
outlet to overheat or catch fire.
ENGLISH
4
This device complies with Industry Canada licence-
exempt RSS standard(s). Operation is subject to the
following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including
interference that may cause undesired operation of the
device.
Under Industry Canada regulations, this radio transmitter
may only operate using an antenna of a type and maximum
(or lesser) gain approved for the transmitter by Industry
Canada. To reduce potential radio interference to other users,
the antenna type and its gain should be so chosen that the
equivalent isotropically radiated power (e.i.r.p.) is not more
than that necessary for successful communication.
This appliance has been approved to the following
standards:
· ICES-003:Issue 6 - Information Technology Equipment
(Including Digital Apparatus) -- Limits and Methods of
Measurement
· ANSI C63.4:2014 - American National Standard for
Methods of Measurement of Radio-Noise Emissions
from Low-Voltage Electrical and Electronic Equipment
in the Range of 9 kHz to 40 GHz
· ANSI C63.10:2013 - American National Standard of
Procedures for Compliance Testing of Unlicensed
Wireless Devices
· 47 CFR Part 15, Subpart B - Radio Frequency
Devices
· 47 CFR Part 15, Subpart C 15.231 - Radio Frequency
Devices
· C22.2 No 46-13 - Electric Air Heaters
· UL 2021 (4th Edition) - Fixed and Location-Dedicated
Electric Room Heaters
· FCC Rules 15C - Federal Communication Commission
· RSP-100 - Labelling Requirements for IC
· RSS-102 Issue 5 (March 2015) - Radio Frequency
(RF) Exposure Compliance of Radiocommunication
Apparatus
· RSS-210 Issue 9 (November 2017) - Licence-Exempt
Radio Apparatus: Category I Equipment
· RSS-Gen Clause 4.6.1 - General Requirements for
Compliance of Radio Apparatus
1.27 DO NOT run power cord under carpeting. DO NOT
cover power cord with throw rugs, runners, or similar
coverings. DO NOT route power cord under furniture
or appliances. Arrange power cord away from traffic
area, and where it will not be tripped over.
1.28 ALWAYS check your appliance cord and plug
connections with each use!
A. MAKE SURE the plug fits tight in the outlet! Faulty
wall outlet connections or loose plugs can cause the
outlet to overheat.
B. Appliances draw more current than small
appliances. Overheating may occur even if it has not
occurred with the use of other appliances.
C. During use check frequently to see if the plug
outlet is HOT! If the outlet or faceplate is HOT,
discontinue use immediately and have a qualified
electrician inspect and/or replace the faulty outlets.
1.29 SAVE THESE
INSTRUCTIONS.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and
(2) This device must accept any interference received,
including interference that may cause undesired
operation.
Note: This product has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This product generates, uses, and
can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that interference will not occur in a particular
installation. If this product does cause harmful interference
to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following
measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and
receiver.
—Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV
technician for help.
Please take attention that changes or modification not
expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
This equipment should be installed and operated with a
minimum distance 8" (203 mm) between the radiator and your
body
User Instructions
ENGLISH
5
2. OPERATING
INSTRUCTIONS
WARNING! Do not operate the appliance if it is
damaged or has malfunctioned. If you suspect
the appliance is damaged or has
malfunctioned call a qualified service
technician to inspect the appliance, and
replace any part of the electrical system if
necessary, before reuse.
Do not disconnect the power at the main supply
while the appliance is running. Use the functions on
the remote to turn the fire off and ensure the on/off
switch has been moved to the off position before
disconnecting.
GENERAL
2.1 The appliance can be operated by the remote control
handset or the manual controls which are on the right
hand side of the viewing window.
NOTE: To use both remote and manual
functions the manual on/off switch must be in
‘ON’ position. In order to prevent the product
becoming too hot, there is a 10s delay when
turning on the heater and a 10s delay when
turning off the heater fan.
The manual button controls basic functions, not
a full range of controls. Use the remote hand set
to carry out all functions.
PREPARATION BEFORE USE
Batteries:
2.2 Ensure that the handset batteries are new and inserted
correctly.
2.3 Dispose of old batteries at an appropriate recycling
facility.
LOCATION OF POWER SWITCH
2.4 The main power switch is located on the control panel
located on the right-hand side of the viewing window,
see Section 2a.
2.5 Switch ON (—) before operating either the remote or
manual controls.
2.6 A long beep is heard to indicate the fire is ready for
use.
2a. Manual Control Panel
2a.1 The manual controls on appliance are located at the
upper right of appliance.
1
Front View
Side
Side
Top
2a.2 Turning on the appliance with the main power switch
on ‘—‘ position. A long beep will be heard.
2a.3 Press “LIGHTS ON/OFF” to turn on or turn off both the
flame and fuel bed at the same time.
2a.4 There are 3 flame color options:
Press “FLAME” button to select the color of flame or
return to the OFF position.
2a.5 There are 14 fuel bed color options:
Press “FUEL BED” button to select the color of fuel
bed or return to the OFF position.
Main Power
(On/Off) Switch
Fuel bed
setting button
Flame setting
button
All Lights
On/ Off button
Reset Button for
Remote Control
Heater Running
Indicators
2
LAYOUT MAY VARY
Note: The appliance will lose the memory for the
light functions when the switch is set to the Off
Position or the remote runs out of power.
Heater Running Indicators (see Diagram 1)
2a.6 When the fan heater is used in conjunction with the
flame or fuel bed effects the heater running indicators
will light up for 10 seconds.
The LEDs will illuminate for 10 seconds if the flame or
fuel bed effect is On.
If the fan heater is used independently, the heater
running indicators will stay on.
User Instructions
ENGLISH
6
Reset Button for Remote Control
2a.7 If the handset loses signal or needs to be replaced
then, see Section 17 in Servicing Section for
details.
2b. Remote Controls
The remote control should be left on a flat surface
in the room where the appliance is installed and
away from any direct flow of hot air.
Timer in
Normal Mode
Flame
Power
Heating/ Advance
Mode
Temperature Sensor
Convection
Display
Fuel Bed
3
Heating
Period
Battery
Power
Actual Room
Temperature
Timer Mode
Advance
Temperature
Setting
Time and
Day
4
Comfort
Setting
Signal Code
2b.1 The remote control works by radio signal.
The handheld transmitter is configured in the factory
with a unique signal code.
IMPORTANT: If the handset loses signal or needs
to be replaced, see Section 17 in Servicing Section
for details.
Turn on/off
2b.2 Press button to turn on the flame effect.
2b.3 Press button to turn off all the functions under the
normal heating control mode including flame effect and
fan heater.
2b.4 Press button to turn off the flame effect under
daily and week timer heating mode.
Week Days/ Time/ Comfort Temperature and change
between Celsius/Fahrenheit
On activation it is recommended that the clock is reset
to the correct time to ensure accuracy of the appliance
operation.
2b.5 Hold the button for 3 seconds to enter the setting
screen.
2b.6 Press the ’ or button to choose setting to
change.
The selected character will be highlighted, see Diagram
5.
5
2b.7 Press the ‘+’ or ‘-’ button to adjust the number.
Time: 24-hour system.
Select Comfort temperature from 15-25℃/ 59-77℉.
Celsius/Fahrenheit : ℃/℉.
2b.8 Press the button for 3 seconds or wait 10 seconds
to save and exit the week, time and heating temperature
setting.
Daily Timer Heating
2b.9 The following heating periods have been preset, these
can be altered if desired:
06:00 until 08:00
17:00 until 22:00
2b.10 Press until shows at the upper right corner of
the screen to enter the daily timer heating mode.
6
User Instructions
ENGLISH
7
User Instructions
2b.11 Hold the button for 6 seconds to enter the daily
heating setting.
A maximum of 3 timed heating periods can be set per
day.
2b.12 Press ‘’ or ’ to choose hour or minute.
2b.13 Press ‘+’ or ‘-’ to set the number.
The minute increment / decrement by 15min per press.
7
2b.14 Hold the button for 3 seconds or wait for 10
seconds to save and exit the heating time period
setting.
2b.15 Check the timer setting. Press to check the daily
timer mode.
2b.16 If the heating needs to be turned off, it will be
necessary to go back to the Normal Control Mode to it
turn off.
When in Daily Timer Mode switching the appliance
off with the remote will stop the light output. The
heat output will continue according to the timer
settings.
Adjusting the Set Temperature
2b.17 Press the ‘+’ or ‘-’ button to increase or decrease the
temperature on the basis of COMF temperature.
COMF means the actual temperature is the same as
setting.
ECO means the actual temperature is 2℃/4℉ lower
than the setting temperature.
ECO- means 4℃/7℉ lower, COMF+ means 2℃/4℉
higher.
COMF++ means 4℃/7℉ higher.
Adaptive start control
According to room temperature and set-pointed
temperature, the heater will automatically determine
the appropriate time to heat to ensure that it will reach
the set-pointed temperature in the set time (up to 45
minutes prior to the set time).
Flame Color Adjustment
2b.18 Press button to enter the flame adjustment
screen.
There are 3 flame color options, indicated by the
number shown in Diagram 7.
There are 6 levels of brightness, including off. This is
indicated by the bar, with the blank bar indicating off,
see Diagram 8.
8
Brightness
Level
Color
Option
2b.19 Press the or ‘ button to cycle through the flame
color options.
2b.20 Press the ‘+’ button to increase the flame brightness.
Press the ‘-’ button to decrease the flame brightness
until off.
Fuel Bed Color Adjustment
2b.21 Press to enter the fuel bed light adjustment
screen.
There are 14 fuel bed color options, indicated by the
number shown in Diagram 8.
There are 6 levels of brightness, including off. This is
indicated by the bar, with the blank bar indicating off,
see Diagram 9.
9
Brightness
Level
Color
Option
2b.22 Press the ’ or ’ button to cycle through the fuel
bed color options.
2b.23 Press the ‘+’ button to increase the fuel bed brightness.
Press the ‘-’ button to decrease the fuel bed brightness
until off.
ENGLISH
8
User Instructions
Normal Control Mode
2b.24 Normal Control Mode is the default setting.
Alternatively press button until the logo is
shown at the upper right corner of the screen, see
Diagram 10.
10
2b.25 Press the ‘+’ or ‘-’ button to adjust the setting
temperature from 17℃ to 25℃/ 59℉ to 77℉.
2b.26 Press button to turn the heat on/off, ON
or OFF will show at the lower right corner of the
screen, see Diagram 11.
11
Note: It is normal for the fan heater to stop running for
periods of time. This happens if the room temperature
is higher than the temperature set on the control.
The heater indicator will be turned off after 10s if the
flame is switched ON. The heater indicator will stay ON
if only the heating function is used.
When in Normal Control Mode switching the
appliance off with the remote will stop both the
light and heat output.
Count Down Timer
This setting is only in normal heating control mode. It
allows the appliance to be returned to Standby after a
set period of time. The heater must be switched on to
use this function.
2b.27 Press to cycle through the setting from Off and 0.5
hours to 9 hours. Timer logo and remaining time will
show on the screen.
The heater of appliance can be automatically run by
using daily timer and weekly timer on the remote.
Battery
The battery power level is indicated at the top right of
the remote control screen, see Diagram 4.
Battery Full No action required
Battery Half Power Ensure new batteries are available.
Battery Empty Replace batteries immediately
Battery replacement is recommended after 1 year. The
Remote requires two 1.5V alkaline AAA batteries.
Changing the batteries will not affect the Timer
Mode settings, however, the clock may need
adjusting.
Week Timer Heating
2b.28 The following heating periods have been preset, these
can be altered if desired:
From Monday to Friday
06:00 until 08:30
17:00 until 22:00
From Saturday to Sunday
06:30 until 09:30
11:00 until 13:00
17:00 until 22:00
2b.29 Press until shows at the upper right corner of
the screen to enter the week heating mode.
12
2b.30 Hold the button for 6 seconds to enter the week
timer heating mode setting.
2b.31 Press ‘’ or ’ to move the cursor (a flashing
underline).
2b.32 Press the button in the corresponding week
position to select (the character is highlighted) or
cancel (the character is displayed normally) the current
setting, the same time period can be selected together.
13
ENGLISH
9
2b.33 Press the ’ button to move the cursor to the time
period setting area.
2b.34 Press ‘’ or ’ button to choose hour or minute.
2b.35 Press ‘+’ or ‘-’ to set the number.
A maximum of 3 timed heating periods can be set per
day.
Minute increment / decrement by 15min per press.
2b.36 Press to set the heating time for the selected day
and return to the week line.
2b.37 Hold the button for 3 seconds or wait for 10
seconds to save and exit the heating time period
setting.
2b.38 Press or ‘’ to check the timer setting for the
week timer heating mode.
2b.39 If the heating needs to be turned off, it will be
necessary to go back to the Normal Control Mode to it
turn off.
When in Weekly Timer Mode switching the
appliance off with the remote will stop the light
output. The heat output will continue according to
the timer settings.
Adjusting the Set Temperature
2b.40 Press the ‘+’ or ‘-’ button to increase or decrease the
temperature on the basis of COMF temperature.
COMF means the actual temperature is the same as
setting.
ECO means the actual temperature is 2℃/ 4℉ lower
than the setting temperature.
ECO- means 4℃/ 7℉ lower.
COMF+ means 2℃/ 4℉ higher.
COMF++ means 4℃/ 7℉ higher.
Adaptive start control
According to room temperature and set-pointed
temperature, the heater will automatically determine
the appropriate time to heat to ensure that it will reach
the set-pointed temperature in the set time (up to 45
minutes prior to the set time).
User Instructions
Advance mode
2b.41 The heating state can be advanced to the next period
is under both the daily and week timer heating mode.
14
If the heater is on in the current period, pressing the
button will turn the heater off.
If the heater is off in the current period, pressing the
button will turn the heater on.
Whether the actual heating will be on/off also depends
on the room temperature and setting temperature.
2b.42 Press to enter the Advance mode under the
daily and week timer heating mode, will show at
the upper right corner of the screen.
2b.43 Press again or timer period ends will exit the
Advance mode.
Window open detecting
2b.44 When the transmitter detects a rapid drop in room
temperature, it will be judged as an open window: the
warning icon will be displayed and the heating will be
turned off automatically.
15
2b.45 After indoor temperature rise or manual intervention
(by operating remote control), it will return to normal
working state.
ENGLISH
10
3. MAINTENANCE
3.1 ALWAYS UNPLUG FROM MAIN SUPPLY
BEFORE CLEANING OR UNDERTAKING ANY
MAINTENANCE.
GENERAL CLEANING
3.2 Only clean the outer casing when it is cold. Do not use
abrasive cleaners.
CLEANING GLASS
3.3 Wipe the glass viewing panel with a damp cloth and
buff with a lint free duster.
Caution: Do not use abrasive cleaners on the
glass panel. Do not spray liquids directly onto any
surface of the unit.
CLEANING THE FUEL EFFECT
To access the fuel effect it will be necessary to remove
the glass viewing panel.
3.4 Ensure the appliance is unplugged.
3.5 There is a clamp at the top of each corner of the glass
viewing panel that secure the glass in place,
see Diagram 15.
15
3.6 Supporting the glass, loosen and remove the 2 clamps.
These can be unscrewed using just finger tips.
3.7 Carefully tip the glass forward and lift out of the lower
tray to remove from the appliance, see Diagram 16.
16
User Instructions
ENGLISH
The fuel effect can now be accessed.
3.8 Remove and wash the fuel effect to remove any dust
particles. Alternatively clean with a lint free duster.
Ensure that the effect is dry before replacing.
Replace the fuel effect see Installation Instructions
Section 5 for layout.
3.9 Replace the glass following the instructions in reverse
order.
When replacing the clamps ensure that the tabs on
the clamps locate in the slots on the appliance, see
Diagram 17.
17
CLEANING AIR INLETS
3.10 Ensure the appliance is unplugged.
3.11 Clean the air inlet and outlet grilles regularly with a soft
cloth or the nozzle of a vacuum cleaner.
Air Outlets
18
Air
Inlets
Air
Inlets
Front View
Top
Side Side
Dust build-up can inhibit efficient performance of
the fan and lead to the safety cut-out operating.
3.12 Keep the area around the appliance clean and free of
fluff, dust or pet hair.
3.13 In particular, build-up of dust etc. can occur around the
heater area. Take particular care to keep this area free
from such particles on a regular basis to prevent build-
up.
BATTERY REPLACEMENT
3.14 When the remote battery is low it must be changed
immediately. Install correct replacement and dispose
of the old battery carefully at an appropriate recycling
facility.
11
Installation Instructions
A 120V 12.5A 60Hz supply is required
Rated power consumption:
Skope E110: 1500 Watts
THIS APPLIANCE MUST BE GROUNDED
IMPORTANT: This appliance must be on its own
dedicated circuit with a minimum 15 amp electrical
supply.
FAILURE TO DO SO WILL INVALIDATE YOUR
WARRANTY.
These instructions cover the following models:
Model
A B C D E F
mm in mm in mm in mm in mm in mm in
Skope E110 1154
45
7
/
16"
1110
43
11
/
16"
1100
43
5
/
16"
1116
43
15
/
16"
352
13
7
/
8"
569
22
3
/
8"
Model
G H I J K
mm in mm in mm in mm in mm in
Skope E110 80
3
1
/
8"
135
5
5
/
16"
220
8
11
/
16"
238
9
3
/
8"
276
10
7
/
8"
TECHNICAL SPECIFICATION
A 3 prong plug with 72" power lead and a separate
hard wiring kit are supplied.
2 x Remote control handset battery (AAA)
Note: The hard wiring from the appliance to the breaker must
be supplied by a qualified electrician. This is not supplied
with the appliance
For Packing Checklist, see Page 28.
Control System Technical Data
Main Control Board Remote Receiver Board Remote Control
Hardware RC01-041A01 V2 RF290B V1.2 RF290A-TX V1.3
Software RC01-041A01 V2 - RF290C V06.0.HEX
Frequency - - ASK/OOK 433.92MHz
Maximum Transmit Power - - 10mW
B
C
H
I
J
K
G
D
A
E
56
F
120V connection
Front
View
Front
Rear
Front
Rear
210-195 Skope E110 Multi Sided Electric Fireplace (43"/1100 mm)
ENGLISH
12
Installation Instructions
1. GENERAL
1.1 TOOLS REQUIRED
A Screw Driver and Drill will be needed.
1.2 UNPACKING THE FIREPLACE
WARNING! DO NOT use this appliance if any part
has been exposed to water.
Immediately call a qualified service technician to
inspect and to replace any part of the electrical system
if necessary.
1.3 Open the packaging carefully and remove the
polystyrene.
Remove and discard the plastic bag.
Keep plastic wrapping away from children.
Be responsible when handling the packing materials.
1.4 Check all parts and accessories are removed before
disposing of any packaging.
If necessary keep the original packaging for future
transport and/or storage.
2. FITTING THE APPLIANCE
ENSURE THAT THE MAIN SUPPLY IS ISOLATED.
2.1 Locating the Skope
Your new Skope may be installed virtually anywhere in
your home. However, when choosing a location ensure
that the general instructions are followed.
2.2 For best results, install out of direct sunlight.
2.3 Make sure there are no pipes or cables behind the
area to be drilled or cut.
2.4 Before installation ensure that the wall is suitably
constructed to support the weight of the appliance.
When the appliance is installed into a decorative
enclosure, it will be necessary to provide
ventilation to the upper section of the appliance
outer casing with a free area of no less than
8.13sq.in (52.5cm
2
). This should be positioned in
the underside of the top section to either or both
sides of the glass.
2.5 The appliance should ideally be located close to a
suitable main receptacle to enable connection. An
extension could be run from an existing receptacle
outlet but this must be carried out by a suitably
qualified electrician.
The electrical receptacle must be easily accessible to
allow disconnection when the appliance is installed.
ENGLISH
2.6 If access to the underside of the appliance will be
limited after installation is complete, ensure the plug
connection on the underside of the appliance has been
considered.
This appliance must be fixed to the wall using
the wall mounting bracket provided, see Section
4 for details.
Note: If installing the appliance into a custom
built corner installation the side brackets will
need to be replaced with the 2 brackets supplied,
see Section 6.
2.7 Electrical Supply Circuit Requirements
Plan the location of the appliance so that it will have
adequate electric power. A 15 AMP, 60Hz circuit is
required for 120V installation. Additional appliances
on the same circuit as this appliance may exceed the
current rating of that circuit. A dedicated circuit is not
required, but is preferred to prevent circuit breaker trips
or fuse failure
2.8 If the power cord is damaged, it must be repaired
by the manufacturer, its authorised service centre or
professional person.
2.9 The product is a zero clearance design.
2.10 Ensure that curtains and furniture are not positioned
close to the chosen position, as this would create a
potential fire hazard or block the heater outlet ducts.
WARNING! KEEP ALL COMBUSTIBLE MATERIALS
AT LEAST 3' (0.9M) FROM THE FRONT OF THE
ELECTRIC FIREPLACE.
Optional Extras
2.11 This appliance can be installed with an optional
decorative trim to finish the installation, see Diagram 1.
For details please contact your Regency retailer.
See installation of this decorative trim in section 5.14
(Center trim and or 6.12 (corner trim)
Product Code Description
910-146 Skope E110 Centre Metal Trim
910-124 Skope E110 Left Hand Corner Metal Trim
910-135 Skope E110 Right Hand Corner Metal Trim
1
Top View
Front
Side
Side
13
3. WIRING KITS
This appliance has already been pre-wired to accept
a 3 prong plug. It also has the option of being hard
wired to the main supply depending on the desired
installation.
Important : When using a 3 prong plug ensure that
wherever this is located that it is accessible. This
cannot be enclosed as there must be access to the
receptacle and 3 prong plug.
This appliance must be connected and grounded in
accordance with local codes, if hard wired. In the absence
of local codes, the use the current CSA C22.1 CANADIAN
ELECTRICAL CODE in Canada or the current ANSI/NFPA 70
NATIONAL ELECTRICAL CODE in the United States.
Hard Wiring
3.1 Remove the 2 screws securing the wiring plate on the
bottom right hand side of the appliance, see Diagram
2.
2
Underside of Appliance
3.2 The wiring kit is attached to the power unit inside the
appliance, see Diagram 3.
3
3.3 Feed the hard wire cable through the large hole in the
plate and hold in place with the grommet.
ENGLISH
Installation Instructions
3.4 Insert a screwdriver into the holes on the top of the
wiring block to open the connectors for Live, Earth and
Neutral.
4
Red
Yellow
Green
Blue
Black
White
3.5 Insert the correct wires into the wiring block.
3.6 Replace the wiring plate, rotating the orientation so the
large hole is covered by the metalwork of the casing
and secure with the screws, see Diagram 5.
5
3.7 The other end of the power cable can now be hard
wired into the main.
NOTE: Isolate the power supply when completing
the installation. The breaker should also be marked
to indicate electric fireplace for ease of serving this
appliance
14
4. MOUNTING BRACKET
The wall mounting bracket will need to be separated
from the appliance.
4.1 Lay the appliance face down on a soft flat surface to
avoid damage.
4.2 Unscrew the mounting bracket from the upper left and
right sides of the appliance, see Diagram 12.
Retain the screws as they will be required during
installation.
6
4.3 Make sure there are no pipes or cables behind the
area to be drilled.
4.4 Decide on the desired height from the floor level to the
bottom of the heater unit.
4.5 The bottom of the wall bracket measures from the
bottom of the appliance, see Diagram 13.
7
A
Appliance A
E110 485mm 19
1
/
8"
Rear View
Side
Top
4.6 To prepare the installation measure the distance from
floor level and using a level draw a line (A dimension)
higher than the intended position of the bottom of the
appliance.
4.7 Position the wall mounting bracket so that the bottom
edge is level with the line drawn on the wall.
4.8 Mark the position of the fixing holes on the wall, see
Diagram 14.
8
4.9 Secure the mounting bracket to a solid wall using the
screws provided. Ensure that the folds on the bracket
are projecting up. If this is going to be installed into
drywall, use the drywall anchors provided.
4.10 Attach the bracket to the wall using the screws
provided ensuring the folds are projecting up, see
Diagram 15.
9
4.11 Lift the appliance onto the bracket.
Ensure the folds locate into the slots on the back of the
appliance, see Diagram 16.
10
4.12 Secure with 2 screws at either side of the bracket, see
Diagram 17.
Note: if a corner application you will only have access
to the open side to secure screw.
11
Installation Instructions
ENGLISH
15
Installation Instructions
4.13 Fasten the two lower fixing bracket to the 2 fixing
points on the underside of the appliance and secure to
the wall using anchors (if required), see Diagrams 18 &
19.
12
Underside of Appliance
13
Underside of Appliance
5. CUSTOM INSTALLATION
The Skope has been designed so that it can be fitted onto a
masonry wall or into a custom built studwork enclosure.
The appliance should ideally be fitted into/onto an internal flat
wall which has already been constructed from either wood
studs and drywall or block/brick. Please ensure that suitable
anchors are used when securing to any hollow or purpose
built cavity.
Note: If installing the appliance into a custom
built corner installation the side brackets will
need to be replaced with the 3 Corner Side Glass
Retainer brackets supplied, see Section 5 for
fitting details.
This appliance is designed so combustible or non-
combustible building materials may be used to finish up to
the appliance casing.
The product is a zero clearance design.
Ensure that the stud or any materials used to seal the cavity
(if required) do not obstruct the air vents on the top and sides
of the appliance.
DO NOT PACK THE VOID AROUND OR ABOVE THE
APPLIANCE WITH INSULATION MATERIALS SUCH AS
MINERAL WOOL.
NOTE: REMOVING THE SIDE GLASS PANELS WILL
NOT BE POSSIBLE FOLLOWING THIS INSTALLATION
METHOD.
This product can be installed in the following configurations:
Non Recessed - the appliance is attached to a wall and
studwork enclosures are built top and bottom and also
anchored to the wall.
This can be finished with 3 sides of glass Left, Right and
Front visible or as a corner installation with Front and Left or
Right glass panel visible depending on location.
Semi Recessed - the appliance can be built into a false
chimney breast in order to hide the depth of the Black Glass
Area leaving only the clear viewing area of the glass visible.
This can be finished with 3 sides of glass Left, right and Front
visible or as a corner installation with front and left or right
glass panel visible depending on location.
3 Sided Installation
- non recessed
Note: All finished facing material should butt up cleanly
to the flanges around the firebox opening.
Rough edges will be visible from the front
view. To maintain a clean finished edge - it is
recommended to install the combustible facing
material with the finished edge against the
fireplace. Alternatively use trim or metal corner
bead to cover cut edges of the facing material.
51 Position the mounting bracket in the desired location
and fit the appliance.
Upper Enclosure
5.2 The upper enclosure can either create a floating shelf
effect or a false chimney breast housing, see Diagram
14.
14
Floating
shelf
style
Min 6
7
/
8
in
(175mm)
False
Chimney
Breast
Front View
ENGLISH
16
Installation Instructions
Ventilation to the upper section enclosure with a
free area of no less than 8.13sq.in/ 52.5cm
2
must
be provided.
Vent(s) should be positioned on the underside
of the top section of the enclosure close to the
glass side(s). This can be positioned to one side
of the appliance as a large singular vent or two
smaller ones on either side this will determine the
size and shape of the enclosure, see Diagram 15.
15
Min
3
1
/
8
in
(80mm)
Min
6
9
/
16
in
(40mm)
Single Sided Vent Configuration (Left or Right)
Min
2
1
/
8
in
60mm
Min
2
1
/
8
in
60mm
Two Sided Vent Configuration
Front View
Front View
Large
Single
Vent
Small Vents
5.3 Build the framework for the upper enclosure to the
desired size, see Diagram 16.
Note: The following dimensions shown are only
minimums. The top enclosure can be increased in
overall size in depth,height and width using a wide
variety of materials
16
48
11
/
16
in 1236 mm
Minimum
6
7
/
8
in
175 mm
Minimum
11
5
/
8
in 296 mm
Minimum
5.4 Finish the bottom of the studwork with suitable
boarding cut to fit around the viewing area, see
Diagram 17.
17
43
15
/
16
in (1116mm)
11
5
/
8
in
(296mm)
Minimum*
10
3
/
8
in
(263mm)
48
11
/
16
in (1236mm) Minimum*
Vent Cutout -
see table
W*
D*
Side
Front
Side
NOTE: A cutout needs to be made to
accommodate the heater vent in the top fascia of
the appliance, see Diagram 18 and table.
18
Heater Vent cutout -
position varies for each
appliance
Vent Cutout Dimensions
Width (W*) Depth (D*)
360mm 14
3
/
4"
25mm 1
"
5.5 Attach the enclosure to the wall ensuring that
there are sufficient anchor points and the wall is
constructed from a suitable load bearing material
that can support the weight of the chosen material
and size, see Diagram 19.
19
5.6 Finish the remaining studwork with drywall and vents.
ENGLISH
17
Lower Enclosure
5.7 The lower enclosure can either create a floating shelf
effect or a false chimney breast housing, see Diagram
20.
20
Floating
shelf
style
Min
3
15
/
16
in
100mm
deep
False
Chimney
Breast
Min
1
9
/
16
in
(40mm)
Min
1
9
/
16
in
(40mm)
Floor Level
Front View
NOTE: When designing the lower enclosure it
may be aesthetically best to match or exceed the
dimensions of the upper enclosure.
5.8 Build the framework for the lower enclosure to the
desired size, see Diagram 21.
Note: The following dimensions shown are only
minimums. The bottom enclosure can be increased
in overall size in depth,height and width using a
wide variety of materials
21
48
11
/
16
in 1236 mm
Minimum
11
5
/
8
in
296 mm
Minimum
3
15
/
16
in
100 mm
Minimum
Installation Instructions
5.9 Finish the top with suitable board material cut to fit
around the viewing area, see Diagram 22.
22
43
15
/
16
in (1116mm)
11
5
/
8
in
(296mm)
Minimum*
8
3
/
4
in
(222mm)
48
11
/
16
in (1236mm) Minimum*
Side
Front
Side
5.10 Ensure provision is made for the power cable and
lower fixing brackets when constructing the lower
enclosure.
5.11 The lower enclosure can locate over or under the lower
flange on the product, see Diagram 23.
Locate under the flange if fitting the optional decorative
trims.
NOTE: If fitting over the flange the material for
this piece must be a maximum thickness of
5
/
8
in
(16mm).
Thicker material will prevent the removal of the
front glass for cleaning and servicing.
23
5.12 Attach the enclosure to the wall ensuring that
there are sufficient anchor points and the wall is
constructed from a suitable load bearing material
that can support the weight of the chosen material
and size.
5.13 Finish the remaining studwork with drywall.
ENGLISH
18
5.14 Place the optional decorative trim on top of the
studwork enclosure and butt up to the edge of the
glass.
24
Optional
Decorative Trim
Side Infills
5.15 Following creation of the top and bottom enclosures
the dark areas of the side panels will still be visible,
see Diagram 25.
25
Side View
Installation Instructions
5.16 Once the top and bottom installation has been finished,
infills can be added to cover the dark areas of the side
panels if desired, see Diagram 26.
Note: The height of the infills will be the distance
between the Upper and Lower flanges minus the
thickness of the non-combustible board used to create
the base enclosure top.
26
A*
B*
C: Customer
preference
Infill Dimensions
Model Height (A*) Depth (B*)
Skope E110 13
7
/
8
in (352mm) - minus
board thickness
80mm 3
1
/
8
in
Front View
Side View
ENGLISH
19
Installation Instructions
3 Sided Installation
- Semi recessed
Note: All finished facing material should butt up cleanly
to the flanges around the firebox opening. Rough
edges will be visible from the front view. To maintain
a clean finished edge - it is recommended to install
the combustible facing material with the finished edge
against the fireplace. Alternatively use trim or metal
corner bead to cover cut edges of the facing material.
5.17 The appliance has black areas on the side panels, see
Diagram 33.
27
Side View
5.18 It is possible to install into a semi recessed chimney
breast to hide these areas, see Diagram 28.
28
5.19 To do this construct a studwork wall to the desired
specification which allows the mounting bracket to be
recessed, see Diagram 29 and table.
29
Mounting Bracket
* See table
for depth
Recess Depth
Model Depth
Skope E110 80mm 3
1
/
8
in
5.20 Fit the appliance on the mounting bracket, see Diagram
30.
30
5.21 Ensure provision is made for the power cable when
finishing the studwork - it will be necessary to
access the plug for servicing.
5.22 Finish off the installation with suitable boarding, see
Diagram 31.
31
Top and Bottom enclosures can now be built following
the same method as a non recessed installation but
reduce the depth by the depth of the built in recess.
ENGLISH
20
6. CORNER INSTALLATION
(IF APPLICABLE)
If access to the underside of the appliance will be
limited after installation is complete, ensure the plug
connection has been considered.
Note: If installing the appliance into a custom
built corner installation the side brackets will
need to be replaced with the 3 Corner Side Glass
Retainer brackets supplied.
If the appliance is to be installed in a right hand
corner, the right hand brackets will need to be
replaced. If left hand, replace the left hand
brackets.
32
Brackets included:
1 x Top right bracket
1 x Top left bracket
1 x Bottom bracket
The remaining left or right top bracket may be recycled
as it will not be required
To change the brackets:
6.1 Support the bracket and remove the 3 screws,
see Diagram 33.
33
Installation Instructions
6.2 Remove the 2 screws securing the lower bracket, see
Diagram 34.
34
6.3 Fit the bottom Corner Side Glass Retainer bracket
ensuring both screws are replaced, see Diagram 35.
35
6.4 Fit the top Corner Side Glass Retainer bracket,
ensuring all 3 screws are replaced, see Diagram 36.
36
6.5 Install the appliance using the desired method and
nish.
This appliance is designed so combustible or
non-combustible building materials may be used to
finish up to the appliance casing.
The product is a zero clearance design.
Ensure that the stud or any materials used to seal the
cavity (if required) do not obstruct the air vents on the
top and sides of the appliance.
ENGLISH
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84

Regency Skope E110 Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues