Whirlpool W10692945 Guide d'installation

Taper
Guide d'installation
INSTALLATION INSTRUCTIONS
IN-LINE SMART KIT
Installation Instructions
For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301
or visit our website at www.whirlpool.com
In Canada, call 1-800-807-6777 or visit our website at www.whirlpool.ca
INSTRUCTIONS D’INSTALLATION
VENTILATEUR DÉPORTÉ INTELLIGENT
Instructions d’installation
Au Canada, pour assistance, installation ou service, composer le 1-800-807-6777
ou visiter notre site Web à www.whirlpool.ca
Table of Contents/Table des matières.............................................................................2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
LIB0100831A/W10708303A
2
TABLE OF CONTENTS
RANGE HOOD SAFETY .................................................................2
INSTALLATION REQUIREMENTS................................................4
Tools and Parts ............................................................................4
Location Requirements................................................................4
Venting Requirements..................................................................5
Electrical Requirements ...............................................................6
INSTALLATION INSTRUCTIONS..................................................6
Prepare Location..........................................................................6
Prepare In-Line Smart Kit.............................................................6
Install In-Line Smart Kit
KVWB40DS Series Range Hoods................................................7
Complete Installation .................................................................10
Make Electrical Connection .......................................................11
Install In-Line Smart Kit
KVUB60DS Series Range Hoods ..............................................12
Complete Installation .................................................................16
Make Electrical Connection .......................................................17
Install In-Line Smart Kit
JXW85DS, JXI85DS, KVWB60DS, and KVIB60DS
Series Range Hoods ..................................................................18
Complete Installation .................................................................23
Make Electrical Connection .......................................................24
Install In-Line Smart Kit
WVW75UC and WV175UC Series Range Hoods......................25
Complete Installation .................................................................29
Make Electrical Connection .......................................................30
WIRING DIAGRAM .......................................................................31
TABLE DES MATIÈRES
SÉCURITÉ DE LA HOTTE DE CUISINIÈRE................................32
EXIGENCES D’INSTALLATION...................................................34
Outillage et pièces......................................................................34
Exigences d’emplacement.........................................................34
Exigences concernant l’évacuation ...........................................35
Spécifications électriques ..........................................................36
INSTRUCTIONS D’INSTALLATION.............................................36
Préparation de l’emplacement...................................................36
Préparation du ventilateur déporté intelligent............................36
Installation du ventilateur déporté intelligent
Hottes série KVWB40DS............................................................37
Achever l’installation ..................................................................40
Raccordement électrique...........................................................41
Installation du ventilateur déporté intelligent
Hottes série KVUB60DS.............................................................42
Achever l’installation ..................................................................46
Raccordement électrique...........................................................47
Installation du ventilateur déporté intelligent
Hottes série JXW85DS, JXI85DS,
KVWB60DS et KVIB60DS ..........................................................48
Achever l’installation ..................................................................53
Raccordement électrique...........................................................54
Installation du ventilateur déporté intelligent
Hottes série WVW75UC et WV175UC.......................................55
Achever l’installation ..................................................................59
Raccordement électrique...........................................................60
SCHÉMA DE CÂBLAGE...............................................................61
RANGE HOOD SAFETY
You can be killed or seriously injured if you don't immediately
You can be killed or seriously injured if you don't follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
3
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.
Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
Do not operate any fan with a damaged cord or plug.
Discard fan or return to an authorized service facility for
examination and/or repair.
Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), the American Society for
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling; do not damage
electrical wiring and other hidden utilities.
Ducted fans must always be vented outdoors.
CAUTION: For general ventilating use only. Do not use
to exhaust hazardous or explosive materials and vapors.
CAUTION: To reduce risk of fire and to properly exhaust
air, be sure to duct air outside - do not vent exhaust air into
spaces within walls or ceilings, attics or into crawl spaces,
or garages.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
WARNING: TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
Always turn hood ON when cooking at high heat or when
flambeing food (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING: TO REDUCE THE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING:a
SMOTHER FLAMES with a close fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
NEVER PICK UP A FLAMING PAN - you may be burned.
DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
Use an extinguisher ONLY if:
– You know you have a class ABC extinguisher, and you
already know how to operate it.
– The fire is small and contained in the area where it
started.
– The fire department is being called.
– You can fight the fire with your back to an exit.
aBased on "Kitchen Fire Safety Tips" published by NFPA.
WARNING: To reduce the risk of fire or electrical shock,
do not use this fan with any solid-state speed control
device.
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read
and follow the instructions provided with any tools listed here.
Tools needed
Drill
1¼" (3.0 cm) drill bit
¹⁄₈" (3.0 mm) drill bit
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Metal duct tape
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
10" (25.4 mm) driver extension
Parts needed
½" (13 mm) UL listed or CSA approved wiring conduit and
connector. The length of the conduit is determined by the
distance between the In-Line Smart Kit and the range hood.
8 - 14 AWG wires, one of each of the following colors:
black, white, red, blue, gray, brown, yellow and green/yellow
(ground). The lengths of the wires are determined by the
distance between the In-Line Smart Kit and the range hood.
3 - UL listed strain relief ½" (13 mm)
6" (15.2 cm) round vent duct
Parts supplied
Remove parts from packages. Check that all parts are included.
1 - 6" (15.5 cm) vent transition without backdraft damper
1 - 6" (15.5 cm) vent transition with backdraft damper
4 - 3.5 x 6.5 mm mounting screws
4 - 3.5 x 9.5 mm mounting screws
1 - 9-pin pigtail electrical connector with 8 wire pigtail
1 - Metal terminal box and cover
16 - UL listed or CSA approved wire connectors
1 - T10 Torx®† adapter
1 - T20® Torx® adapter
1 - Plastic wire clip
4 - 5 x 45 mm mounting screws
3 - 2.9 x 13 mm mounting screws
1 - UL listed or CSA approved plastic strain reliefs
1 - in-line housing
1 - in-line base
1 - in-line mounting bracket
1 - Cover plate
1 - UL listed or CSA approved wire clamp
Location Requirements
IMPORTANT: Observe all governing codes and ordinances. Have
a qualified technician install the In-Line Smart Kit.
All openings in the ceiling and wall where the In-Line Smart Kit
will be installed must be sealed.
For Mobile Home Installations
The installation of this in-line blower system must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
†®TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.
6"
(15.2 cm)
4" (10.2 cm)
10¹¹⁄₁₆"
(27.1 cm)
4" (10.2 cm)
6" (15.2 cm)
9⁵⁄₈"
(24.5 cm) 26" (66.0 cm)
12"
(30.5 cm)
5
Venting Requirements
Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Use round, metal venting only. Rigid metal venting is
recommended. Plastic or metal foil venting is not
recommended.
The length of the vent system and the number of elbows
should be kept to a minimum to provide efficient
performance.
For the Most Efficient and Quiet Operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps and metal duct tape to seal all joints in the vent
system.
The vent system must have a damper.
Use weatherproof caulking compound to seal the exterior
wall or roof opening around the cap.
The size of all venting should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air flow. A thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Typical In-Line Smart Kit Installations
A 6" (15.2 cm) round vent system is needed for installations (not
included).
The In-Line Smart Kit inlet and outlet openings are 6" (15.2 cm)
round. The exhaust (outlet) opening on the range hood must also
be 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vents create
back pressure and air turbulence that can greatly reduce In-Line
Smart Kit performance.
The vent system may terminate either through the roof or wall.
NOTE: Plywood may be used as a mounting base to span open
areas between ceiling joists and rafters. If used, be sure to use
plywood capable of supporting 25 Ib (11.3 kg).
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
The maximum recommended equivalent vent length is 35 ft
(10.7 m).
Example Vent System
The following example falls within the maximum recommended
vent length of 35 ft (10.7 m).
A. Mounted on top of ceiling joists (vertical duct)
B. Mounted to cross-members tied to trusses
(horizontal duct)
Vent Piece 6" (15.2 cm) Round
45° elbow
2.5 ft
(0.8 m)
90° elbow
5.0 ft
(1.5 m)
1 - 90° elbow = 5.0 ft (1.5 m)
1 - wall cap = 0.0 ft (0.0 m)
8 ft (2.4 m) straight = 8.0 ft (2.4 m)
Length of system = 13.0 ft (3.9 m)
AB
90 elbow 6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
6
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 (latest
edition), or CSA Standards C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is
required.
If the house has aluminum wiring, follow the procedure
below:
1. Connect a section of solid copper wire to the pigtail
leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial rating plate.
The model/serial plate is located behind the filter on the rear
wall of the range hood.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 (latest edition) and all local codes and
ordinances.
INSTALLATION INSTRUCTIONS
Prepare Location
CAUTION: To reduce the risk of fire and electrical shock, install
the In-Line Smart Kit only with the range hood model series listed
in these instructions.
Before cutting or drilling into the ceiling or walls, make sure
there is proper clearance within the ceiling or wall for the vent
system.
When cutting or drilling into the ceiling or wall, do not
damage electrical wiring on other hidden utilities.
Determine which venting method to use: roof, or wall.
The In-Line Smart Kit must be installed to a secure structure
of the roof, ceiling, wall, or floor. The In-Line Smart Kit may
also be installed into a new or existing frame construction.
The structure must be capable of supporting 25 Ib (11.3 kg).
The installation holes on the in-line mounting bracket to be
used to mount the In-Line Smart Kit to the structure.
Prepare In-Line Smart Kit
1. Using two or more people, move the In-Line Smart Kit and
the range hood to a workbench or work space.
2. Unpack all parts supplied with the In-line smart kit. Use the
“Tools and Parts” section of this manual to verify that all parts
have been included.
3. Remove the In-line-Smart assembly from the wooden
packaging material
NOTE: Do not move the In-Line Smart Kit to the mounting
location until the range hood blower motor has been installed in
the in-line housing. Do not install the range hood until the In-Line
Smart Kit and vent system have been installed.
IMPORTANT: Installation of the In-Line Smart Kit is model
specific. Before installing, determine the model number of the
range hood to be used with the In-Line Smart Kit. See the
appropriate “Install In-Line Smart Kit” section.
A. Distance between installation holes: 24" (61 cm),
19½" (49.2 cm), 18" (46.2 cm), and 14½" (36.8 cm)
B. Distance between installation holes: 7¾" (19.7 cm)
C. Mounting structure
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
7
Install In-Line Smart Kit
KVWB40DS Series Range Hoods
Remove Blower Motor from Range Hood Housing
1. Disconnect power.
2. Using two or more people, place the range hood on its back.
Be sure to set the range hood on a covered surface.
3. Using the T10 Torx® adapter, remove the 8 screws securing
the bottom panel to the range hood. Remove the bottom
panel and set it aside.
4. Using the T10 Torx® adapter, remove the 4 screws from the
blower motor cover plate. Remove the cover plate from the
motor and set it aside.
5.
Disconnect the blower motor from the range hood wiring. Press
the top and bottom clip of the 9-pin electrical connector to
disconnect.
6. Using the T20® Torx® adapter with a long extension, remove
the 6 screws that secure the blower motor and insulation
retainers (2) to the range hood housing. Set the screws and
insulating retainers aside.
A. Bottom panel
B. Screws (8)
C. Range hood
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
C
B
A
A. Blower motor cover plate
B. Screws (4)
C. Range hood
A. Blower motor
B. Screws - insulation retainer (2)
C. Insulation retainers (2)
D. Screws - blower motor mounting (4)
A
C
B
A
B
C
D
D
8
7. Push on the blower motor to disengage the two spring tabs
from the keyhole slots in the top of the range hood housing.
8. Remove the blower motor from the range hood housing and
set it aside.
9. Reinstall the 2 insulation retainers and 2 screws to the range
hood housing. Use the T20® Torx® adapter with a long
extension.
10. Reinstall the blower motor cover plate and bottom panel. Use
the T10 Torx® adapter and the screws previously removed.
Assemble the In-Line Smart Kit
1. Using the T20® Torx® adapter, remove the 3 screws from the
terminal box cover on the in-line housing. Set the screws and
cover aside.
2. Disassemble the in-line housing from the in-line base. Using
the T20® Torx® adapter, remove the 2 screws from inside the
terminal box near the top and the 2 screws located on the
opposite side. Lift the housing off the base and mounting
bracket.
3. Install the vent transition without a backdraft damper to the
bottom of the in-line base. Use the T10 Torx® adapter and
install 2 - 3.5 x 9.5 mm mounting screws to secure the
transition to the base.
4. Place the blower motor inside the in-line housing.
5.
Engage the blower motor spring tabs into the keyhole slots
located at the top of the in-line housing. Push the motor so the
spring tabs are secured into the small neck of the keyhole slots.
6. Locate the 4 screws removed from the blower motor. Use
these 4 screws to secure the motor to the in-line housing.
Tighten with the T20® Torx® adapter.
7. Place the in-line housing (with blower motor installed) near
the in-line base.
A. Keyhole slots
A. Terminal box cover
B. Screws (3)
A. In-line housing
B. In-line base
C. Screws (4)
A
A
B
A
B
C
C
A. In-line base
B. Vent transition (without backdraft damper)
C. 3.5 x 9.5 mm screws (2)
A. Keyhole slots
A. In-line housing
B. Blower motor
C. Screws (4)
A
B
C
A
B
C
A
9
8. Connect the 9-pin connector from the blower motor to the
9-pin connector inside the in-line base.
9. Slide the in-line housing inside the in-line base. Align the
mounting holes in the in-line housing to the mounting holes in
the in-line base. Secure with the 4 screws removed when the
in-line housing was removed from the in-line base. Use the
T20® Torx® adapter to secure the screws.
10. Install the vent transition with a backdraft damper to the top
of the in-line housing. Use the T10 Torx® adapter and install
2 - 3.5 x 9.5 mm mounting screws to secure the transition to
the housing.
Install In-Line Smart Kit
The In-Line Smart Kit must be installed to a secure structure of
the roof, ceiling, wall, or floor. The In-Line Smart Kit may also be
installed into a new or existing frame construction.
1. Using two or more people, position the assembled In-Line
Smart Kit (housing, base and mounting bracket) in its final
mounting location.
2. Use a pencil to mark the location of the 4 mounting holes.
3. Drill 4 mounting pilot holes where marked.
4. Install the In-Line Smart assembly in its final location using
4 - 5 x 45 mm mounting screws mm screws.
A. In-line housing
B. Vent transition (with backdraft damper)
C. 3.5 x 9.5 mm screws (2)
A
B
C
A. 5 x 45 mm screws (4)
B. Secure structure (joist, rafters or trusses)
C. In-line smart assembly
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
A
BC
10
Complete Installation
Determine and make all necessary cuts and drill holes for the
vent system.
IMPORTANT: When cutting or drilling into the ceiling or wall, be
sure to not damage electrical wiring or other hidden utilities.
1. Install the range hood in its final location. Use the Installation
Instructions provided with the range hood.
2. Determine the location where the ¹⁄₂" (13 mm) wiring conduit
will be routed through the ceiling or wall to connect the In-
Line Smart Kit and the range hood.
3. Drill a 1¹⁄₄" (3.2 cm) hole(s) in this location.
4. Locate the terminal boxes on the In-Line Smart Kit and the
range hood.
5. Remove the terminal box cover on the range hood. Set the
cover and screws aside.
6. Remove the electrical knockout from the In-Line Smart Kit (B,
see the following illustration) and the range hood terminal
box.
7. Install the UL listed or CSA approved strain reliefs (3) in the
range hood and In-Line Smart kit electrical knockouts.
8. Connect the vent system to the vent transition on the range
hood. Connect the vent system to the vent transition located
on the bottom In-Line Smart Kit. Use clamps and metal duct
tape to seal all joints.
A. Range hood terminal box cover
B. Electrical knockouts
C. Range hood terminal box
D. Screws (3)
A. In-line smart kit terminal box
B. Electrical knockouts
A
D
C
B
A
B
A. Vent transition - in-line smart kit (bottom)
B. Vent system
C. Vent transition - range hood
A
B
C
11
Make Electrical Connection
Connect Range Hood
1. Connect the 9-pin pigtail electrical connector provided with
the In-Line Smart Kit to the 9-pin electrical connector inside
the range hood.
Connect Range Hood and In-Line Smart Kit
1. Measure the distance between the In-Line Smart Kit and the
range hood terminal box.
2. Install 8 - 14 AWG wires with an insulating sleeve or conduit
between the terminal box and UL listed strain reliefs.
3. Connect together the set of 8 wires in the In-Line Smart Kit
terminal box.
4. Connect together the set of 8 wires in the range hood
terminal box.
A. 9-pin connector (range hood)
B. 9-pin pigtail electrical connector
C. Plastic strain relief
D. Electrical knockout
E. Range hood (inside)
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
A. Distance between in-line smart kit
and the range hood terminal box
A. Conduit and 8 - 14 AWG wires
B. Terminal box (range hood)
C. 9-pin pigtail electrical connector
D. Range hood power supply
E. Home power supply
A
A
B
C
D
E
12
Connect In-Line Smart Kit
Electrical Connection In-Line Smart Kit
1. Use a UL listed or CSA approved wire connector to connect
the black wires together.
2. Use a UL listed or CSA approved wire connector to connect
the white wires together.
3. Use a UL listed or CSA approved wire connector to connect
the red wires together.
4. Use a UL listed or CSA approved wire connector to connect
the blue wires together.
5. Use a UL listed or CSA approved wire connector to connect
the gray wires together.
6. Use a UL listed or CSA approved wire connector to connect
the brown wires together.
7. Use a UL listed or CSA approved wire connector to connect
the yellow wires together.
8. Use a UL listed or CSA approved wire connector to connect
the green/yellow wires together.
9. Tighten the UL listed or CSA approved strain relief.
Electrical Connection Range Hood
10. Repeat all steps above to make the electrical connection in
the range hood terminal box.
11. Connect power supply wires together using the “Make
Electrical Connections” section in the range hood manual.
12. Reinstall the terminal box covers on the In-Line Smart Kit and
range hood.
13. Reconnect power.
Install In-Line Smart Kit
KVUB60DS Series Range Hoods
NOTE: KVUB60DS series range hoods must be top vented for
installation with the In-Line Smart Kit.
Remove Blower Motor from Range Hood Housing
1. Disconnect power.
2. Using two or more people, place the range hood on its back.
Be sure to set the range hood on a covered surface.
3. Using the T10 Torx® adapter, remove the 8 screws securing
the bottom panel to the range hood. Remove the bottom
panel and set it aside.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
A. Bottom panel
B. Screws (8)
C. Range hood
B
C
A
13
4. Using the T10 Torx® adapter, remove the 4 screws from the
blower motor cover plate. Remove the cover plate from the
motor and set it aside.
5.
Disconnect the blower motor from the range hood wiring. Press
the top and bottom clip of the 9-pin electrical connector to
disconnect.
6. Using the T20® Torx® adapter with a long extension, remove
the 4 screws that secure the blower motor to the range hood
housing and set them aside.
7. Push on the blower motor to disengage the 2 spring tabs
from the keyhole slots in the top of the range hood housing.
8. Remove the blower motor from the range hood housing and
set it aside.
9. Remove the electrical knockout from the top of the range
hood and install 1 - UL listed or CSA approved plastic strain
relief. Run the 9-pin connector and pigtail wires through the
strain relief as shown.
10. Connect the 9-pin connector installed to the 9-pin connector
on the inside of the range hood electrical box.
A. Blower motor cover plate
B. Screws (4)
C. Range hood
A. Blower motor
B. Screws - blower motor mounting (4)
C
B
A
B
A
A. Keyhole slots
A. Range hood (top)
B. 9-pin electrical connector (wires)
C. UL listed or CSA approved plastic
strain relief
D. Electrical knockout
A
AB
C
D
14
11. Install the metal terminal box supplied with the In-Line Smart
Kit to the top of the range hood using 2 - 3.5 x 6.5 mm
mounting screws.
12. Reinstall the blower motor cover plate and bottom panel. Use
the T10 Torx® adapter and the screws previously removed.
Assemble the In-Line Smart Kit
1. Using the T20® Torx® adapter, remove the 3 screws from the
terminal box cover on the in-line housing. Set the screws and
cover aside.
2. Disassemble the in-line housing from the in-line base. Using
the T20® Torx® adapter, remove the 2 screws from inside the
terminal box near the top and the 2 screws located on the
opposite side. Lift the housing off the base and mounting
bracket.
3. Install the vent transition without a backdraft damper to the
bottom of the in-line base. Use the T10 Torx® adapter and
install 2 - 3.5 x 9.5 mm mounting screws to secure the
transition to the base.
4. Place the blower motor inside the in-line housing.
5.
Engage the blower motor spring tabs into the keyhole slots
located at the top of the in-line housing. Push the motor so the
spring tabs are secured into the small neck of the keyhole slots.
6. Locate the 4 screws removed from the blower motor. Use
these 4 screws to secure the motor to the in-line housing.
Tighten with the T20® Torx® adapter.
7. Place the in-line housing (with blower motor installed) near
the in-line base.
A. Terminal box cover
B. Screws (3)
A. In-line housing
B. In-line base
C. Screws (4)
A
B
A
B
C
C
A. In-line base
B. Vent transition (without backdraft damper)
C. 3.5 x 9.5 mm screws (2)
A. Keyhole slots
A. In-line housing
B. Blower motor
C. Screws (4)
A
B
C
A
B
C
A
15
8. Connect the 9-pin connector from the blower motor to the
9-pin connector inside the in-line base.
9. Slide the in-line housing inside the in-line base. Align the
mounting holes in the in-line housing to the mounting holes in
the in-line base. Secure with the 4 screws removed when the
in-line housing was removed from the in-line base. Use the
T20® Torx® adapter to secure the screws.
10. Install the vent transition with a backdraft damper to the top
of the in-line housing. Use the T10 Torx® adapter and install
2 - 3.5 x 9.5 mm mounting screws to secure the transition to
the housing.
Install In-Line Smart Kit
The In-Line Smart Kit must be installed to a secure structure of
the roof, ceiling, wall, or floor. The In-Line Smart Kit may also be
installed into a new or existing frame construction.
1. Using two or more people, position the assembled In-Line
Smart Kit (housing, base and mounting bracket) in its final
mounting location.
2. Use a pencil to mark the location of the 4 mounting holes.
3. Drill 4 mounting pilot holes where marked.
4. Install the In-Line Smart assembly in its final location using
4 - 5 x 45 mm screws.
A. In-line housing
B. Vent transition (with backdraft damper)
C. 3.5 x 9.5 mm screws (2)
A
B
C
A. Mounting screws (4)
B. Secure structure (joist, rafters or trusses)
C. In-line smart assembly
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
A
BC
16
Complete Installation
Determine and make all necessary cuts and drill holes for the
vent system.
IMPORTANT: When cutting or drilling into the ceiling or wall, be
sure to not damage electrical wiring or other hidden utilities.
1. Install the range hood in its final location. Use the Installation
Instructions provided with the range hood.
2. Determine the location where the ¹⁄₂" (13 mm) wiring conduit
will be routed through the ceiling or wall to connect the In-
Line Smart Kit and the range hood.
3. Drill a 1¹⁄₄" (3.2 cm) hole(s) in this location.
4. Locate the terminal box on the In-Line Smart Kit and the
terminal box on the top of the range hood.
5. Remove the cover from the range hood terminal box. Set the
cover and screws aside.
6. Remove the electrical knockout from the In-Line Smart Kit (B,
see the following illustration) and the range hood terminal
box.
7. Install the UL listed or CSA approved strain reliefs (3) in the
range hood and In-Line Smart kit electrical knockouts.
8. Connect the vent system to the vent transition on the range
hood. Connect the vent system to the vent transition located
on the bottom In-Line Smart Kit. Use clamps and metal duct
tape to seal all joints.
A. Terminal box cover
B. Screws (2)
C. Terminal box
D. Electrical knockout
A. In-line smart kit terminal box
B. Electrical knockouts
A
B
B
C
D
A
B
A. Vent transition - in-line smart kit (bottom)
B. Vent system
C. Vent transition - range hood
A
BC
17
Make Electrical Connection
Connect Range Hood and In-Line Smart Kit
1. Measure the distance between the In-Line Smart Kit and the
range hood terminal box.
2. Install 8 - 14 AWG wires with an insulating sleeve or conduit
between the terminal box and UL listed strain reliefs.
3. Connect together the set of 8 wires in the In-Line Smart Kit
terminal box.
4. Connect together the set of 8 wires in the range hood
terminal box.
Connect In-Line Smart Kit
Electrical Connection In-Line Smart Kit
1. Use a UL listed or CSA approved wire connector to connect
the black wires together.
2. Use a UL listed or CSA approved wire connector to connect
the white wires together.
3. Use a UL listed or CSA approved wire connector to connect
the red wires together.
4. Use a UL listed or CSA approved wire connector to connect
the blue wires together.
5. Use a UL listed or CSA approved wire connector to connect
the gray wires together.
6. Use a UL listed or CSA approved wire connector to connect
the brown wires together.
7. Use a UL listed or CSA approved wire connector to connect
the yellow wires together.
8. Use a UL listed or CSA approved wire connector to connect
the green/yellow wires together.
9. Tighten the UL listed or CSA approved strain relief.
Electrical Connection Range Hood
10. Repeat all steps above to make the electrical connection in
the range hood terminal box.
11. Connect power supply wires together using the “Make
Electrical Connections” section in the range hood manual.
12. Reinstall the terminal box cover on the In-Line Smart Kit and
range hood.
13. Reconnect power.
A. Distance between in-line smart kit
and the range hood terminal box
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
18
Install In-Line Smart Kit
JXW85DS, JXI85DS, KVWB60DS, and KVIB60DS Series Range Hoods
Remove Blower Motor from Range Hood Housing
1. Disconnect power.
2. Using two or more people, place the range hood on its back.
Be sure to set the range hood on a covered surface.
3. Open the stainless steel panel.
4. Using the T10 Torx® adapter remove the screws securing the
filter retainer panel to the range hood. See the following
illustrations for screw locations and numbers.
JXW85DS and JXI85DS Range Hoods
KVWB60DS and KVIB60DS Range Hoods
A. Stainless steel panel
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
A
A. Range hood
B. Filter retainer panel
C. Screws (6)
A. Range hood
B. Filter retainer panel
C. Screws (12)
C
A
B
A
B
C
19
5. Disconnect the blower motor from the range hood wiring.
Using a flat blade screwdriver, and press down on the top clip
of the 9-pin electrical connector while pressing the bottom
clip. Unplug the blower motor from the 9-pin connector.
6. Using the T10 Torx® adapter, remove the screw that secures
the temperature sensor to the bottom rear panel.
7. Using the T10 Torx® adapter, remove the 2 screws from the
bottom of the rear panel. Pull the bottom rear panel towards
the front of the range hood to disengage the spring tabs from
the bottom flange of the rear panel. Set the panel and screws
aside.
8. Using the T20® Torx® adapter with a long extension, remove
the 4 screws that secure the blower motor to the range hood
housing and set them aside.
9. Push on the blower motor to disengage the 2 spring tabs
from the keyhole slots in the top of the range hood housing.
10. Reinstall the bottom rear panel using the T10 Torx® adapter
and the 2 screws previously removed.
11.
Reinstall the temperature sensor to the bottom rear panel using
the T10 Torx
®
adapter and the screw previously removed.
12. Reinstall the filter retainer panel using the T10 Torx® adapter
and the screws previously removed.
13. Using the T10 Torx® adapter, remove the 7 screws securing
the plastic electrical box cover to the range hood. Remove
the cover and set it aside.
A. Temperature sensor
B. Sensor mounting screw
A. Bottom rear panel mounting screws
B. Bottom rear panel
B
A
AA
B
A. Range hood housing
B. Blower motor
C. Screws (4)
A. Keyhole slots
A. Plastic electrical box cover
B. Screws (7)
A
B
C
A
AB
20
14. Remove the 2 electrical knockouts from the top of the range
hood electrical box and install a UL listed or CSA approved
plastic strain relief into the front knockout.
15. Remove the 9-pin connector inside the range hood electrical
box. Insert a flat-blade screwdriver into the lateral clips while
removing the connector (see the following illustration).
16. Cut the wire tie that is closest to the 9-pin electrical connector.
17. Mount the cover plate supplied with the In-Line Smart Kit to
close the opening in the electrical box.
NOTE: Bend the cover plate along the perforation so it
conforms to the shape of the electrical box.
18. Run the 3 electrical power wires (black, white and green) and
the cover plate ground wire (green) through the small
electrical knockout in the top of the range hood electrical
box. Secure all 4 wires with 1 - UL listed or CSA approved
wire clamp. Snap the wire clamp into the electrical knockout.
19. Run the 9-pin pigtail electrical connector through the UL
listed or CSA approved strain relief.
NOTE: The 9-pin connector must be inside the range hood
electrical box.
20. Connect the 9-pin connector installed to the 9-pin connector
on the inside of the range hood electrical box.
21. Reinstall the plastic electrical box cover. Use the T10 Torx®
and the screws previously removed.
A. Wire tie
B. 9-pin electrical connector (wires)
A. Opening
B. Cover plate
C. Cover plate ground wire
A
B
A
C
B
A. Electrical power wires (4)
B. UL listed or CSA approved wire clamp
C. Range hood electrical box
A. UL listed or CSA approved strain relief
B. 9-pin pigtail electrical connector
C. Range hood electrical box
A
B
C
A
B
C
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Whirlpool W10692945 Guide d'installation

Taper
Guide d'installation

dans d''autres langues