INSTRUCTIONS
GENERAL
This luminaire is designed for use in outdoor applica-
tions and must adhere to 25°C Max ambient temperature
limitation. Install and maintain it according to the
following recommendations.
A. MOUNTING
READ THOROUGHLY BEFORE INSTALLING
WARNING
Risk of electric shock
Turn power off before servicing
see instructions
CAUTION
Unit will fall if not installed properly
Follow installation instructions
1. Place fixture on appropriately sized tenon.
2. Tighten fixture set screws to 18 to 22 ft-lbs. of torque.
3. Install Lamp (see section C of instruction sheet for lamp
instructions)
OPTIONAL PHOTO CONTROL
(Ordered separately)
Rotate base casting so that
PE window points away
from other light sources.
PROTECTIVE SHIELD
SLIDE BRACKET
Move bracket to open position
(as shown) for electrical cord
passage. Be sure bracket is in
closed position when no
electrical cord is in place.
4. Install refractor making sure that asymmetric refractors
are properly oriented with respect to their “house side” or
“street side” labeling.
5. Tighten globe set screws to lightly contact globe.
6. Wire unit (see section B of instruction sheet for wiring
instructions)
7. Move slide bracket to closed position if it is in open
position and if no cord is present.
(See illustration)
8. Close door securely.
35-201578-106 (10/03)
B. CÂBLAGE
Toutes les connexions doivent être conformes aux normes
électriques nationales et à la réglementation locale en
vigueur.
Assurez-vous que la tension électrique est adéquate en
vérifiant la plaque signalétique.
APPAREILS À TENSION UNIQUE :
Tous les ballasts à tension unique sont préalablement
câblés, de sorte que l'utilisateur n'a plus qu'à connecter les
conducteurs d'alimentation.
APPAREILS À TENSIONS MULTIPLES (120/208/240/277 volts)
Branchez le conducteur du ballast à cosse isolée sur la
borne de tension appropriée, conformément aux indications
sur la plaque signalétique des bornes du ballast.
APPAREILS À PUISSANCES MULTIPLES :
Des ballasts à puissances multiples sont disponibles avec
diverses combinaisons de puissance. Consultez les instruc-
tions de câblage sur l'étiquette de câblage à l'intérieur du
luminaire.
Les accessoires optionnels (comme les fusibles et les
commandes photoélectriques) sont conçus pour une
tension spécifique.
Remplacez les fusibles d'alimentation uniquement par
des fusibles de même type et de même capacité.
Lorsque vous modifiez la tension électrique sur des
appareils reconnectables, déplacez uniquement le
conducteur avec le connecteur isolé.
C. LAMPES
Utilisez uniquement des lampes conformes aux exigences
de la plaque signalétique. Respectez les recommandations
du fabricant de la lampe, ainsi que les restrictions
s'appliquant à l'utilisation de la lampe, notamment sur le
type de ballast, la position de brûlage, etc.
SERRAGE DE LA LAMPE : La lampe doit être solidement
insérée avec un couple de 35 lb/po (normes NEMA-EEI), ce qui
peut être obtenu avec un serrage très ferme. Le serrage doit
être suffisant pour enfoncer complètement la lampe et
charger le contact central de la douille.
REMARQUE : L'utilisation de lubrifiants sur la base de la
lampe ou sur les douilles peut provoquer une usure rapide
de la lampe et annule la garantie du luminaire.
D. ENTRETIEN ET NETTOYAGE
Il sera occasionnellement nécessaire de nettoyer l'extérieur
du réfracteur pour préserver la puissance d'éclairage. La
fréquence des nettoyages dépendra des saletés du milieu
ambiant et de la puissance d'éclairage minimale qui est
nécessaire à l'utilisateur. Le réfracteur peut être nettoyé avec
n'importe quel savon, détergent ou liquide lave-vitre non
abrasif, puis rincé avec de l'eau propre et essuyé.
La puissance d'éclairage d'un luminaire dépend également
de l'usure de la lampe. Dans les applications où la puissance
d'éclairage est critique, il pourrait être préférable de
remplacer les lampes avant qu'elles ne brûlent. Le fabricant
de la lampe peut vous indiquer comment la puissance
d'éclairage diminue avec l'usure.
Risque de brûlure
Laissez le bloc d'ampoule refroidir
avant d'y toucher
ATTENTION
RÉFRACTEUR INTERNE EN VERRE
(optionnel)
Installer avant la lampe. Trouver
l'étiquette indiquant le côté de la
rue et orienter en conséquence.
Fixer avec la bride fournie.
DOUILLE
Les lampes doivent être serrées
avec un couple de 35 lb-po.
RÉCEPTACLE DU BALLAST
Avec des ballasts à tensions
multiples, suivre les instructions
ci-dessus.
BLOC DE FUSIBLES
(optionnel)
LIGNE
TERRE
RÉCEPTACLE SIMPLEX
(optionnel)
PLAQUE DE BORNES
LIGNE ou NEUTRE
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or
maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred
to GE Lighting Solutions.
g
GE Lighting Solutions is a subsidiary of the General Electric Company. Evolve and other trademarks belong to GE Lighting Solutions. The GE brand and logo are trademarks of the General Electric Company.
© 2011 GE Lighting Solutions. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
16943533----888
g
GE
Lighting Solutions
CAUTION
Risk of burn
Allow lamp/fixture to cool before
handling
B. WIRING
Make all electrical connections in accordance with
the National Electrical Code and any applicable
local code requirements.
Verify that supply voltage is correct by comparing it
to nameplate.
IF SINGLE VOLTAGE:
All single voltage ballasts are pre-wired such that user
need only connect the supply conductors.
IF MULTIVOLT: (120/208/240/277 volts)
Connect the ballast lead with the insulated terminal to
the desired voltage terminal as indicated on the ballast
terminal nameplate.
IF MULTIWATT:
Multiwatt ballasts are available in various combinations
of wattage. See wiring instructions on wiring tag inside
the luminaire.
Optional Features such as fusing and photocontrols
are voltage specific.
Replace power fuses only with fuses of the same
type and rating.
When changing voltage on reconnectable units,
move only the lead with the insulated connector.
C. LAMPS
INTERNAL GLASS REFRACTOR
(optional)
Install before lamp. Find street
side labeling and align
accordingly. Secure with
supplied clamp.
SOCKET
Lamps should be tightened to
35 inch-pounds torque.
BALLAST CANNISTER
For multivolt ballasts,
see above instructions.
FUSE BLOCK
(optional)
LINE
GROUND
SIMPLEX RECEPTACLE
(optional)
TERMINAL BOARD
LINE or NEUTRAL
Use only lamps specified on nameplate. Observe
lamp manufacturer’s recommendations and restric-
tions on lamp operation, particularly ballast type,
burning position, etc.
LAMP TIGHTNESS: The lamp should be securely inserted
to NEMA-EEI specified torque of 35 inch-pounds, which is
best achieved by very firmly tightening to insure application
of sufficient torque. Tightening must be sufficient to fully
depress and load center contact of socket.
NOTE: Use of lubricants on lamp base or sockets
can cause rapid lamp failure and voids fixture
warranty.
D. MAINTENANCE AND CLEANING
It will occasionally be necessary to clean the refractor to
maintain light levels. Frequency of cleaning will depend on
ambient dirt level and minimum light level which is
acceptable to the user. The refractor should be washed in a
solution of warm water and mild, nonabrasive household
detergent, rinsed with clean water and wiped dry.
The light output of a luminaire is dependent on the age
of the lamp. In applications where the light level is critical,
it may be desirable to replace lamps before they burn out.
The lamp manufacturer can provide data showing how the
lamp light output decreases with use.
GEH-5913
Luminaire Patriarch
INSTRUCTIONS
GÉNÉRALITÉS
Ce luminaire a été conçu pour une utilisation à l'extérieur sans
que la température ambiante ne dépasse 25°C. Installez-le et
entretenez-le conformément aux recommandations ci-dessous.
A. MONTAGE
LIRE ATTENTIVEMENT AVANT D'INSTALLER
1. Placez le luminaire sur un tenon de grosseur appropriée.
2. Serrez les vis d'arrêt du luminaire avec un couple de 18 à 22 lb-pi.
3. Installez la lampe (voir la section C de cette notice
d'installation).
COMMANDE PHOTOÉLECTRIQUE
OPTIONNELLE
(se commande séparément)
Faites tourner la base de façon
à ce que la fenêtre du module
photoélectrique soit orientée
vers d'autres sources
lumineuses.
ÉCRAN PROTECTEUR
ÉTRIER COULISSANT
Placer l'étrier en position ouverte
(tel qu'illustré) pour laisser passer
un cordon électrique. Si aucun
cordon n'est utilisé, ne pas oublier
de placer en position fermée.
4. Installez le réfracteur en vous assurant que les réfracteurs
asymétriques sont correctement orientés par rapport aux
étiquettes « House Side » (côté maison) et « Street Side »
(côté rue).
5. Serrez les vis d'arrêt du globe de façon à ce qu'elles touchent
légèrement ce dernier.
6. Câblez le luminaire (voir les instructions de câblage dans la
section B de cette notice d'installation).
7. Poussez l'étrier coulissant jusqu'à la position fermée, s'il est en
position ouverte et qu'aucun cordon n'est utilisé (voir
l'illustration).
8. Fermez solidement la porte.
Risque d'électrocution
Mettre hors tension avant d'intervenir
Suivez les instructions
AVERTISSEMENT
Risque de chute en cas de mauvais
montage
Suivez les instructions
ATTENTION
Ces instructions n'ont pas pour destination de couvrir tous les détails ou variantes de l'équipement, ni de répondre à toutes les éventualités que vous pourriez rencontrer pendant l'installation,
le fonctionnement ou l'entretien. Si vous souhaitez des informations complémentaires, ou si vous rencontrez un problème particulier qui ne soit pas adressé de votre point de vue d'acheteur,
le sujet doit être remonté jusqu'à la société GE Lighting Solutions
g
GE
Lighting Solutions
CAUTION
Risk of burn
Allow lamp/fixture to cool before
handling
B. WIRING
Make all electrical connections in accordance with
the National Electrical Code and any applicable
local code requirements.
Verify that supply voltage is correct by comparing it
to nameplate.
IF SINGLE VOLTAGE:
All single voltage ballasts are pre-wired such that user
need only connect the supply conductors.
IF MULTIVOLT: (120/208/240/277 volts)
Connect the ballast lead with the insulated terminal to
the desired voltage terminal as indicated on the ballast
terminal nameplate.
IF MULTIWATT:
Multiwatt ballasts are available in various combinations
of wattage. See wiring instructions on wiring tag inside
the luminaire.
Optional Features such as fusing and photocontrols
are voltage specific.
Replace power fuses only with fuses of the same
type and rating.
When changing voltage on reconnectable units,
move only the lead with the insulated connector.
C. LAMPS
INTERNAL GLASS REFRACTOR
(optional)
Install before lamp. Find street
side labeling and align
accordingly. Secure with
supplied clamp.
SOCKET
Lamps should be tightened to
35 inch-pounds torque.
BALLAST CANNISTER
For multivolt ballasts,
see above instructions.
FUSE BLOCK
(optional)
LINE
GROUND
SIMPLEX RECEPTACLE
(optional)
TERMINAL BOARD
LINE or NEUTRAL
Use only lamps specified on nameplate. Observe
lamp manufacturer’s recommendations and restric-
tions on lamp operation, particularly ballast type,
burning position, etc.
LAMP TIGHTNESS: The lamp should be securely inserted
to NEMA-EEI specified torque of 35 inch-pounds, which is
best achieved by very firmly tightening to insure application
of sufficient torque. Tightening must be sufficient to fully
depress and load center contact of socket.
NOTE: Use of lubricants on lamp base or sockets
can cause rapid lamp failure and voids fixture
warranty.
D. MAINTENANCE AND CLEANING
It will occasionally be necessary to clean the refractor to
maintain light levels. Frequency of cleaning will depend on
ambient dirt level and minimum light level which is
acceptable to the user. The refractor should be washed in a
solution of warm water and mild, nonabrasive household
detergent, rinsed with clean water and wiped dry.
The light output of a luminaire is dependent on the age
of the lamp. In applications where the light level is critical,
it may be desirable to replace lamps before they burn out.
The lamp manufacturer can provide data showing how the
lamp light output decreases with use.
GEH-5913
Luminaire Patriarch
INSTRUCTIONS
GÉNÉRALITÉS
Ce luminaire a été conçu pour une utilisation à l'extérieur sans
que la température ambiante ne dépasse 25°C. Installez-le et
entretenez-le conformément aux recommandations ci-dessous.
A. MONTAGE
LIRE ATTENTIVEMENT AVANT D'INSTALLER
1. Placez le luminaire sur un tenon de grosseur appropriée.
2. Serrez les vis d'arrêt du luminaire avec un couple de 18 à 22 lb-pi.
3. Installez la lampe (voir la section C de cette notice
d'installation).
COMMANDE PHOTOÉLECTRIQUE
OPTIONNELLE
(se commande séparément)
Faites tourner la base de façon
à ce que la fenêtre du module
photoélectrique soit orientée
vers d'autres sources
lumineuses.
ÉCRAN PROTECTEUR
ÉTRIER COULISSANT
Placer l'étrier en position ouverte
(tel qu'illustré) pour laisser passer
un cordon électrique. Si aucun
cordon n'est utilisé, ne pas oublier
de placer en position fermée.
4. Installez le réfracteur en vous assurant que les réfracteurs
asymétriques sont correctement orientés par rapport aux
étiquettes « House Side » (côté maison) et « Street Side »
(côté rue).
5. Serrez les vis d'arrêt du globe de façon à ce qu'elles touchent
légèrement ce dernier.
6. Câblez le luminaire (voir les instructions de câblage dans la
section B de cette notice d'installation).
7. Poussez l'étrier coulissant jusqu'à la position fermée, s'il est en
position ouverte et qu'aucun cordon n'est utilisé (voir
l'illustration).
8. Fermez solidement la porte.
Risque d'électrocution
Mettre hors tension avant d'intervenir
Suivez les instructions
AVERTISSEMENT
Risque de chute en cas de mauvais
montage
Suivez les instructions
ATTENTION
Ces instructions n'ont pas pour destination de couvrir tous les détails ou variantes de l'équipement, ni de répondre à toutes les éventualités que vous pourriez rencontrer pendant l'installation,
le fonctionnement ou l'entretien. Si vous souhaitez des informations complémentaires, ou si vous rencontrez un problème particulier qui ne soit pas adressé de votre point de vue d'acheteur,
le sujet doit être remonté jusqu'à la société GE Lighting Solutions
g
GE
Lighting Solutions
GEH-5913
Patriarch
Luminaire
INSTRUCTIONS
GENERAL
This luminaire is designed for use in outdoor applica-
tions and must adhere to 25°C Max ambient temperature
limitation. Install and maintain it according to the
following recommendations.
A. MOUNTING
READ THOROUGHLY BEFORE INSTALLING
WARNING
Risk of electric shock
Turn power off before servicing
see instructions
CAUTION
Unit will fall if not installed properly
Follow installation instructions
1. Place fixture on appropriately sized tenon.
2. Tighten fixture set screws to 18 to 22 ft-lbs. of torque.
3. Install Lamp (see section C of instruction sheet for lamp
instructions)
OPTIONAL PHOTO CONTROL
(Ordered separately)
Rotate base casting so that
PE window points away
from other light sources.
PROTECTIVE SHIELD
SLIDE BRACKET
Move bracket to open position
(as shown) for electrical cord
passage. Be sure bracket is in
closed position when no
electrical cord is in place.
4. Install refractor making sure that asymmetric refractors
are properly oriented with respect to their “house side” or
“street side” labeling.
5. Tighten globe set screws to lightly contact globe.
6. Wire unit (see section B of instruction sheet for wiring
instructions)
7. Move slide bracket to closed position if it is in open
position and if no cord is present.
(See illustration)
8. Close door securely.
35-201578-106 (10/03)
B. CÂBLAGE
Toutes les connexions doivent être conformes aux normes
électriques nationales et à la réglementation locale en
vigueur.
Assurez-vous que la tension électrique est adéquate en
vérifiant la plaque signalétique.
APPAREILS À TENSION UNIQUE :
Tous les ballasts à tension unique sont préalablement
câblés, de sorte que l'utilisateur n'a plus qu'à connecter les
conducteurs d'alimentation.
APPAREILS À TENSIONS MULTIPLES (120/208/240/277 volts)
Branchez le conducteur du ballast à cosse isolée sur la
borne de tension appropriée, conformément aux indications
sur la plaque signalétique des bornes du ballast.
APPAREILS À PUISSANCES MULTIPLES :
Des ballasts à puissances multiples sont disponibles avec
diverses combinaisons de puissance. Consultez les instruc-
tions de câblage sur l'étiquette de câblage à l'intérieur du
luminaire.
Les accessoires optionnels (comme les fusibles et les
commandes photoélectriques) sont conçus pour une
tension spécifique.
Remplacez les fusibles d'alimentation uniquement par
des fusibles de même type et de même capacité.
Lorsque vous modifiez la tension électrique sur des
appareils reconnectables, déplacez uniquement le
conducteur avec le connecteur isolé.
C. LAMPES
Utilisez uniquement des lampes conformes aux exigences
de la plaque signalétique. Respectez les recommandations
du fabricant de la lampe, ainsi que les restrictions
s'appliquant à l'utilisation de la lampe, notamment sur le
type de ballast, la position de brûlage, etc.
SERRAGE DE LA LAMPE : La lampe doit être solidement
insérée avec un couple de 35 lb/po (normes NEMA-EEI), ce qui
peut être obtenu avec un serrage très ferme. Le serrage doit
être suffisant pour enfoncer complètement la lampe et
charger le contact central de la douille.
REMARQUE : L'utilisation de lubrifiants sur la base de la
lampe ou sur les douilles peut provoquer une usure rapide
de la lampe et annule la garantie du luminaire.
D. ENTRETIEN ET NETTOYAGE
Il sera occasionnellement nécessaire de nettoyer l'extérieur
du réfracteur pour préserver la puissance d'éclairage. La
fréquence des nettoyages dépendra des saletés du milieu
ambiant et de la puissance d'éclairage minimale qui est
nécessaire à l'utilisateur. Le réfracteur peut être nettoyé avec
n'importe quel savon, détergent ou liquide lave-vitre non
abrasif, puis rincé avec de l'eau propre et essuyé.
La puissance d'éclairage d'un luminaire dépend également
de l'usure de la lampe. Dans les applications où la puissance
d'éclairage est critique, il pourrait être préférable de
remplacer les lampes avant qu'elles ne brûlent. Le fabricant
de la lampe peut vous indiquer comment la puissance
d'éclairage diminue avec l'usure.
Risque de brûlure
Laissez le bloc d'ampoule refroidir
avant d'y toucher
ATTENTION
RÉFRACTEUR INTERNE EN VERRE
(optionnel)
Installer avant la lampe. Trouver
l'étiquette indiquant le côté de la
rue et orienter en conséquence.
Fixer avec la bride fournie.
DOUILLE
Les lampes doivent être serrées
avec un couple de 35 lb-po.
RÉCEPTACLE DU BALLAST
Avec des ballasts à tensions
multiples, suivre les instructions
ci-dessus.
BLOC DE FUSIBLES
(optionnel)
LIGNE
TERRE
RÉCEPTACLE SIMPLEX
(optionnel)
PLAQUE DE BORNES
LIGNE ou NEUTRE
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or
maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred
to GE Lighting Solutions.
g
GE Lighting Solutions is a subsidiary of the General Electric Company. Evolve and other trademarks belong to GE Lighting Solutions. The GE brand and logo are trademarks of the General Electric Company.
© 2011 GE Lighting Solutions. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
16943533----888
g
GE
Lighting Solutions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

GE PTR Guide d'installation

Catégorie
Projecteurs
Taper
Guide d'installation

dans d''autres langues