Ariens 986061 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur

Ce manuel convient également à

20003110 A
OPERATOR’S MANUAL
MANUEL D’UTILISATION
MANUAL DEL OPERADOR
7,500 WATT GENERATOR
GÉNÉRATRICE DE 7 500 WATTS
GENERADOR 7 500 WATTS
MODEL NO. 986061
NO. DE MODÈLE / NÚM. DE MODELO
ITEM NO. AR907511P Series/Série
ARTICLE NO. / ART. NÚM.
NOTICE AVIS AVISO
Do not use E15 or E85 fuel (or fuel containing greater than 10% ethanol) in this product. It is a
violation of federal law and will damage the unit and void your warranty.
Ne pas utiliser d’essence E15 ou E85 (ou un carburant contenant plus de 10 % d’éthanol) dans
ce produit. Une telle utilisation représente une violation de la loi fédérale et endommagera l’appareil et annulera la garantie.
No utilice combustibles E15 o E85 (ni combustibles que contengan más de 10 % de etanol) con este producto. Esto constituye
una violación a la ley federal, dañará la unidad y anulará la garantía.
WARNING: To reduce the risk of
injury, the user must read and understand
the operator’s manual before using this
product.
TABLE OF CONTENTS
Important Safety Instructions ............3-4
Specific Safety Rules ...........................4
Symbols ............................................5-7
Electrical ...........................................8-9
Features .............................................10
Assembly ......................................11-12
Operation ......................................13-15
Maintenance .................................15-17
Troubleshooting .................................18
Warranty ........................................19-21
Parts Ordering / Service ....... Back Page
AVERTISSEMENT : Pour
réduire les risques de blessures,
l’utilisateur doit lire et veiller à bien
comprendre le manuel d’utilisation avant
d’employer ce produit.
TABLE DES MATIÈRES
Instructions importantes
concernant la sécurité ......................3-4
Règles de sécurité particulières ...........4
Symboles ..........................................5-7
Caractéristiques électriques .............8-9
Caractéristiques ................................. 10
Assemblage ..................................11-12
Utilisation ......................................13-15
Entretien ........................................15-17
Dépannage .........................................18
Garantie ........................................19-21
Commande de pièces /
réparation ............................Páge arrière
ADVERTENCIA: Para reducir el
riesgo de lesiones, el usuario debe leer
y comprender el manual del operador
antes de usar este producto.
ÍNDICE DE CONTENIDO
Instrucciones de seguridad
importantes .......................................3-4
Reglas de seguridad específicas .........4
Símbolos ...........................................5-7
Aspectos eléctricos ..........................8-9
Características ...................................10
Armado .........................................11-12
Funcionamiento ............................13-15
Mantenimiento ..............................15-17
Corrección de problemas ..................18
Garantía ........................................19-21
Pedidos de piezas/
servicio ............................ Pág. posterior
SAVE THIS MANUAL FOR
FUTURE REFERENCE
CONSERVER CE MANUEL
POUR FUTURE RÉFÉRENCE
GUARDE ESTE MANUAL
PARA FUTURAS CONSULTAS
NEUTRAL BONDED TO FRAME
CONNECTEUR NEUTRE RELIÉ AU CADRE /
PUNTO NEUTRO CONECTADO AL MARCO
ii
See this fold-out section for all of the figures
referenced in the operator’s manual.
Consulter l’encart à volets afin
d’examiner toutes les figures mentionnées
dans le manuel d’utilisation.
Consulte esta sección desplegable para ver todas
las figuras a las que se hace referencia en el
manual del operador.
iii
Fig. 1
G - 240 volt AC circuit breaker (disjoncteur de
c.a. 240 V, disyuntor de circuito de CA 240 V)
H - 120/240 volt AC 30 amp receptacle (prise
120/240 V c.a. 30 A, 120/240 V de CA 30 A
receptáculos)
I - Muffler (échappement, silenciador)
J - Battery (pile, batería)
K - Oil cap/dipstick (bouchon/jauge d’huile, tapa
de relleno de aceite/varilla medidora de aceite)
L - Oil drain plug (huiler le bouchon d’égout,
perno de drenaje de aceite)
M- Engine switch (commutateur du moteur,
interruptor del motor)
N - Analog hour meter (compteur d’heures
analogique, horómetro analógico)
O
- Recoil starter grip (poignée du démarreur à
rappel, mango del arrancador retráctil)
P - Air filter (filtre à air, filtro de aire)
Q - Choke (d’étranglement, anegador)
R - Fuel tank vapor vent (évent de vapeur du
réservoir de carburant, respirador del vapor
del tanque de combustible)
A - Handle lock pin (goupille de verrouillage de
poignée, pasador de seguro del mango)
B - Fuel cap (bouchon de carburant, tapa del
tanque de combustible)
C - Fuel tank (réservoir de carburant, tanque de
combustible)
D - Ground terminal (borne de terre, terminal de
conexión a tierra)
E - 120 volt AC circuit breaker (disjoncteur de
c.a. 120 V, disyuntor de circuito de CA 120 V)
F - 120 volt AC GFCI 20 amp receptacles (prises
120 V c.a. 20 A protégées par le disjoncteur
de fuite à la terre, 120 V de C.A. GFCI 20 A
receptáculos)
I
A
P
Q
N
R
B
C
D
F
E
G
J
K
L
M
O
H
iv
Fig.7
Fig.8
A - Lanyard (bracelet, correa)
B - Hole (trou, agujero)
C - Handle (poignée, mango)
D - Handle lock pin (goupille de blocage de la
poignée, pasador de seguro del mango)
D
A
C
B
A - Battery bracket (support de pile, soporte de la
batería)
B - Positive (+) terminal [borne positive (+), tapa
del terminal positiva (+)]
C - Negative (–) terminal [borne négative (–),
terminal negativa (–)]
D - Black cable (–) [fil noir (–), cable negro (–)]
E - Bolt (boulon, perno)
F - Washer (rondelle, arandela)
G - Nut (écrou, tuerca)
H - Red cable (+) [fil rouge (+), cable rojo (+)]
G
B
C
H
E
F
D
A
A
C
E
B
C
D
Fig. 3
Fig. 2
A - Bolt (boulon, perno)
B - Frame (cadre, armazón)
C - Washer (rondelle, arandela)
D - Frame support (support de cadre, apoyo de
bastidor)
E - Nut (écrou, tuerca)
F - Rubber foot (patin en caoutchouc, pie de
goma)
Fig.5
A - Hitch pin (goupille de sûreté, pasador del
enganche)
B - Washer (rondelle, arandela)
C - Wheel (roué, rueda)
D - Axle (essieu, eje)
C
D
A
B
Fig. 6
A
B
C
A - Lanyard (bracelet, correa)
B - Handle lock pin (goupille de blocage de la
poignée, pasador de seguro del mango)
C - Frame (cadre, armazón)
A - Socket wrench (clé à douille, llave de
casquillo)
B - Combination wrench (clé mixte, llave de
combinación)
C - Phillips screwdriver (tournevis cruciforme,
destornillador Phillips)
A
B
C
Fig. 4
A
C
F
4
6
5
8
9
7
15
10
7
11
8
12
13
14
3
2
1
7
v
OFF
ENGINE
SWITCH
ON
START
Fig. 14
B
A
Fig. 9
Fig. 10
A - Oil cap/dipstick (bouchon/ jauge d’huile, tapa
de relleno de aceite/varilla medidora de aceite)
B - Oil fill hole (orifice de remplissage d’huile,
agujero de llenado de aceite)
A
B
A - Engine switch (commutateur du moteur,
interruptor del motor)
B - Fuel cap (bouchon de carburant, tapa del
tanque de combustible)
C - Fuel tank (réservoir de carburant, tanque de
combustible)
D - Recoil starter grip (poignée du démarreur à
rappel, mango del arrancador retráctil)
E - Lock button (bouton de verrouillage, lock
button)
Fig. 11
A - Recoil starter grip (poignée de démarreur à
rappel, mango del arrancador retráctil)
B - Fuel valve (robinet de carburant, válvula de
combustible)
Fig. 12
A - Engine switch (interrupteur du moteur,
interruptor del motor)
B - Off (arret, apagado)
C - Start (démarrage, arranque)
D - Lock button (bouton de verrouillage, botón
del seguro)
Fig. 13
A - Pull choke to the START position [mettre
le d’étranglement en position START
(DÉMARRAGE), coloque del anegador en la
posición START (ARRANQUE)]
B - Push choke to the RUN position [tirez le
l’étrangleur en position RUN (MARCHE),
tire del anegador en la posición RUN
(FUNCIONAMIENTO)]
D
C
A
B
D
OFF
A
OFF
B
OFF (ARRET
APAGADO)
ON (MARCHE
ENCENDIDO)
C
B
Fig. 15
A
E
2 — English
KEEP AT LEAST
20 FT. AWAY
CO Detector
in Living Areas
Only use OUTSIDE and
FAR AWAY from windows,
doors, and vents.
Exhaust (CO)
Direct exhaust AWAY
from all windows, doors,
and vents.
LOCATE GENERATOR AT LEAST 20 FT.* AWAY TO REDUCE THE
RISK OF CARBON MONOXIDE GETTING INSIDE THE HOME
* Minimum distance as recommended by U.S. Department of Health and Human
Services Centers for Disease Control and Prevention (www.cdc.gov/co). Your specific
home and/or wind conditions may require additional distance.
To register your Ariens product,
please visit: www.ariens.com
WARNING:
GROUNDING THE GENERATOR
If this generator will be used only with cord and plug-connected equipment,
National Electric Code does not require that the unit be grounded. However,
other methods of using the generator may require grounding to reduce the risk
of shock or electrocution. Consult a qualified electrician, electrical inspector,
or local agency having jurisdiction for local codes or ordinances to find out if
grounding is needed in your situation before using the generator.
When grounding is required, the nut and ground terminal on the frame are
used to connect the generator to a suitable ground source. The ground path
should be made with #8 size wire. Connect the terminal of the ground wire
between the lock washer and the nut, and tighten the nut fully. Connect the
other end of the wire securely to a suitable ground source that is in contact
with the soil for a minimum distance of 8 ft.
The National Electric Code contains several practical ways in which to es-
tablish a good ground source. If a steel or iron rod is used, it should be at
least 5/8 in. diameter, and if a nonferrous rod is used, it should be at least
1/2 in. diameter and be listed as material for grounding. If a rock bottom is
encountered before reaching a depth of 8 ft., drive the ground rod in at an angle of up to 45°. If the rock bottom is
again encountered, the rod can be buried in a trench that is at least 30 in. deep. In all cases, the upper end of the
grounding rod should either be flush with (or below) the ground or must be otherwise protected from physical damage.
All electrical tools and appliances operated from this generator must be properly grounded by use of a third wire or
be “Double Insulated.”
It is recommended to:
1. Use electrical devices with 3-prong grounded plugs.
2. Use an extension cord intended for outdoor use with a 3-pole receptacle and a 3-prong plug at opposite ends to
ensure continuity of the ground protection from the generator to the appliance.
Check and adhere to all applicable federal, state, and local regulations relating to grounding specifications. Consult a
qualified electrician or service personnel if the grounding instructions are not completely understood or if in doubt as
to whether the generator is properly grounded.
3 — English
DANGER:
Carbon Monoxide. Using a generator indoors CAN KILL
YOU IN MINUTES.
Generator exhaust contains high levels of carbon
monoxide (CO), a poisonous gas you cannot see or smell.
If you can smell the generator exhaust, you are breathing
CO. But even if you cannot smell the exhaust, you could
be breathing CO.
Never use a generator inside homes, garages,
crawlspaces, or other partly enclosed areas. Deadly
levels of carbon monoxide can build up in these
areas. Using a fan or opening windows and doors
does NOT supply enough fresh air.
ONLY use a generator outdoors and far away from
open windows, doors, and vents. These openings
can pull in generator exhaust.
Even when you use a generator correctly, CO may
leak into the home. ALWAYS use a battery-powered or
battery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator
has been running, move to fresh air RIGHT AWAY. See
a doctor. You could have carbon monoxide poisoning.
WARNING:
Read and understand all instructions. Failure to follow
all instructions listed below could result in electrocution,
fire, and/or carbon monoxide poisoning, which can cause
death or serious injury.
WARNING:
In some applications, National Electric Code requires
generator to be grounded to an approved earth ground.
Before using the ground terminal, consult a qualified
electrician, electrical inspector, or local agency having
jurisdiction for local codes or ordinances that apply to
the intended use of the generator.
SAVE THESE INSTRUCTIONS
This manual contains important instructions for this product
that should be followed during installation and maintenance
of the generator.
Do not connect to a building’s electrical system unless
the generator and transfer switch have been properly
installed and the electrical output has been verified by
a qualified electrician. The connection must isolate the
generator power from utility power and must comply with
all applicable laws and electrical codes.
Do not allow children or untrained individuals to use this
unit.
Do not start or operate the engine in a confined space,
building, near open windows, or in other unventilated space
where dangerous carbon monoxide fumes can collect.
Carbon monoxide, a colorless, odorless, and extremely
dangerous gas, can cause unconsciousness or death.
Keep all bystanders, children, and pets at least 10 feet
away.
Wear sturdy and dry shoes or boots. Do not operate while
barefoot.
Do not operate generator when you are tired or under the
influence of drugs, alcohol, or medication.
Keep all parts of your body away from any moving parts
and all hot surfaces of the unit.
Do not touch bare wire or receptacles.
Do not use generator with electrical cords which are worn,
frayed, bare, or otherwise damaged.
Before storing, allow the engine to cool for 30 minutes
and drain fuel from the unit.
Do not operate or store the generator in rain, snow, or
wet weather.
Store the generator in a well-ventilated area with the fuel
tank empty. Fuel should not be stored near the generator.
Empty fuel tank, close fuel valve, and restrain the unit
from moving before transporting in a vehicle.
To reduce the risk of fire and burn injury, handle fuel with
care. It is highly flammable.
Do not smoke while handling fuel.
Store fuel in a container approved for gasoline.
Position the unit on level ground, stop engine, and allow
to cool for five minutes before refueling.
Loosen fuel cap slowly to release pressure and to keep
fuel from escaping around the cap.
Tighten the fuel cap securely after refueling.
Wipe spilled fuel from the unit.
Never attempt to burn off spilled fuel under any
circumstances.
Generators vibrate in normal use. During and after the
use of the generator, inspect the generator as well as
extension cords and power supply cords connected to
it for damage resulting from vibration. Have damaged
items repaired or replaced as necessary. Do not use plugs
or cords that show signs of damage such as broken or
cracked insulation or damaged blades.
For power outages, permanently installed stationary
generators are better suited for providing back-up power
to the home. Even a properly connected portable generator
can become overloaded. This may result in overheating
or stressing the generator components, possibly leading
to generator failure.
IMPORTANT SAFETY INSTRUCTIONS
4 — English
WARNING:
When this generator is used to supply a building
wiring system: generator must be installed by a quali-
fied electrician and connected to a transfer switch as
a separately derived system in accordance with NFPA
70, National Electrical Code. The generator shall be
connected through a transfer switch that switches all
conductors other than the equipment grounding con-
ductor. The frame of the generator shall be connected to
an approved grounding electrode. Failure to isolate the
generator from power utility can result in death or injury
to electric utility workers.
Do not use this generator to provide power for emergency
medical equipment or life support devices.
This generator has a neutral bonded condition. This
means the neutral conductor is electrically connected to
the frame of the machine.
Exhaust contains poisonous carbon monoxide, a color-
less, odorless gas. Breathing exhaust can cause loss
of consciousness and can lead to death. If running in a
confined or partially-enclosed area, the air may contain
a dangerous amount of carbon monoxide. To keep ex-
haust fumes from building up, always provide adequate
ventilation.
Always use a battery-powered carbon monoxide detec-
tor when running the generator. If you begin to feel sick,
dizzy, or weak while using the generator, shut it off and
get to fresh air immediately. See a doctor. You may have
carbon monoxide poisoning.
Place the generator on a flat, stable surface with a slope
of no more than 4°.
Operate in a well-ventilated, well-lit area isolated from
working areas to avoid noise interference.
Operating the generator in wet conditions could result in
electrocution. Keep the unit dry.
Keep the generator a minimum of 3 feet away from all
types of combustible material.
Do not operate generator near hazardous material.
Do not operate generator at a gas or natural gas filling
station.
Do not touch the muffler or cylinder during or immediately
after use; they are HOT and will cause burn injury.
Do not allow the generator’s gas tank to overflow when
filling. Fill to 1 in. below the top neck of the gasoline tank
to allow for fuel expansion. Do not cover the fuel tank cap
when the engine is running. Covering the fuel tank cap
during use may cause engine failure and/or damage to
the tool.
Do not smoke when filling the generator with gasoline.
Shut down the engine and allow to cool completely before
adding gasoline or lubricant to the generator.
Do not remove the oil dipstick or the fuel tank cap when
the engine is running.
Pay close attention to all safety labels located on the
generator.
Keep children a minimum of 10 feet away from the gen-
erator at all times.
The unit operates best in temperatures between 23°F and
104°F with a relative humidity of 90% or less.
Operating voltage and frequency requirement of all
electronic equipment should be checked prior to plug-
ging them into this generator. Damage may result if the
equipment is not designed to operate within a +/- 10%
voltage variation, and +/- 3 hz frequency variation from
the generator name plate ratings. To avoid damage, al-
ways have an additional load plugged into the generator
if solid state equipment (such as a television set) is used.
A power line conditioner is recommended for some solid
state applications.
When battery is not in use, keep it away from other metal
objects like paper clips, coins, keys, nails, screws, or
other small metal objects that can make a connection
from one terminal to another. Shorting the battery termi-
nals together may cause burns or a fire.
For outdoor use only.
Save these instructions. Refer to them frequently and use
them to instruct others who may use this product. If you
loan someone this product, loan them these instructions
also.
Use only authorized replacement parts and accessories
and follow instructions in the Maintenance section of this
manual. Use of unauthorized parts or failure to follow
maintenance instructions may create a risk of shock or injury.
Maintain the unit per maintenance instructions in this
Operator’s Manual.
Inspect the unit before each use for loose fasteners, fuel
leaks, etc. Replace damaged parts.
IMPORTANT SAFETY INSTRUCTIONS
SPECIFIC SAFETY RULES
5 — English
SYMBOLS
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper
interpretation of these symbols will allow you to operate the product better and safer.
SYMBOL NAME DESIGNATION/EXPLANATION
Safety Alert Indicates a potential personal injury hazard.
Read Operator’s Manual
To reduce the risk of injury, user must read and understand
operator’s manual before using this product.
Wet Conditions Alert Do not expose to rain or use in damp locations.
Electric Shock
Failure to use in dry conditions and to observe safe practices can
result in electric shock.
Toxic Fumes
Running generator gives off carbon monoxide, an odorless, color-
less, poison gas. Breathing carbon monoxide can cause nausea,
fainting, or death.
Fire/Explosion
Fuel and its vapors are extremely flammable and explosive. Fire
or explosion can cause severe burns or death.
Hot Surface
To reduce the risk of injury or damage, avoid contact with any hot
surface.
Lifting Hazard
To reduce the risk of serious injury, avoid attempting to lift the
generator alone.
Ground
Consult with local electrician to determine grounding requirements
before operation.
The following signal words and meanings are intended to explain the levels of risk associated with this product.
SYMBOL SIGNAL MEANING
DANGER:
Indicates an imminently hazardous situation, which, if not avoided, will result
in death or serious injury.
WARNING:
Indicates a potentially hazardous situation, which, if not avoided, could result
in death or serious injury.
CAUTION:
Indicates a potentially hazardous situation, which, if not avoided, may result in
minor or moderate injury.
NOTICE:
(Without Safety Alert Symbol) important information not related to an injury
hazard, such as a situation that may result in property damage.
6 — English
SYMBOLS
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper
interpretation of these symbols will allow you to operate the product better and safer.
SYMBOL NAME DESIGNATION/EXPLANATION
Recycle Symbol
This product uses lead acid (Pb) batteries. Local, state or federal
laws may prohibit disposal of batteries in ordinary trash. Consult
your local waste authority for information regarding available re-
cycling and/or disposal options.
VVolts Voltage
A Amperes Current
Hz Hertz Frequency (cycles per second)
W Watt Power
hrs Hours Time
gal Gallon Volume
qt Quart Volume
SAFETY LABELS
The information below can be found on the generator. For
your safety, please study and understand all of the labels
before starting the generator.
If any of the labels come off the unit or become hard to read,
contact an authorized service center for replacement.
You WILL be KILLED or SERIOUSLY HURT if you do not
follow the Operator’s Manual instructions.
Risk of Fire. Do not add fuel while the product is operat-
ing.
Generator is a potential source of electric shock. Do not
expose to moisture, rain, or snow. Do not operate with
wet hands or feet.
Exhaust contains poisonous carbon monoxide gas that
can cause unconsciousness or DEATH. Operate in well-
ventilated, outdoor areas away from open windows or
doors.
Do not expose to rain or use in damp locations.
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a
poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and
windows are open.
Only use OUTSIDE and far away from windows, doors,
and vents.
7 — English
SYMBOLS
FUEL WARNING
No smoking when filling with gasoline.
Do not overfill. Full level is 1 in. below
the top of the fuel neck. Stop the en-
gine for five minutes before refueling to
avoid the heat from the muffler igniting
fuel vapors.
ENGINE LUBRICANT WARNING
You must add lubricant before first
operating the generator. Always check
the lubricant level before each opera-
tion. The lubricant level should always register
between the hatched areas on the dipstick.
The unit is equipped with a sensor which will
automatically shut off the engine if the lubricant
level falls below a safe limit.
GROUNDING WARNING
This generator does not include a ground rod
or copper wire. Call a qualified electrician for
local grounding requirements.
HOT SURFACE WARNING
Do not touch the muffler or aluminum cylinder of the engine. They
are very HOT and will cause severe burns. Don’t put any flam-
mable or combustible materials in the direct path of the exhaust.
CLEARANCE WARNING
While operating and storing, keep at least 3 feet of clearance on
all sides of this product, including overhead. Allow a minimum
of 30 minutes of “cool down” time before storage. Heat created
by muffler and exhaust gases could be hot enough to cause
serious burns and/or ignite combustible objects.
SPARK ARRESTOR
Operation of this equipment may create sparks that can start fires
around dry vegetation. A spark arrestor may be required. The
operator should contact local fire agencies for laws or regulations
relating to fire prevention requirements.
DANGER
DANGER
PELIGRO
L’utilisation d’une génératrice à l’intérieur PEUT VOUS TUER ENQUELQUES MINUTES.
Les génératrices produisent du monoxyde de carbone, un gaz mortel incolore et inodore.
NE JAMAIS utiliser à l’intérieur d’une maison ou d’un garage,MÊME SI les portes et
les fenêtres sont ouvertes.
Utiliser uniquement À L’EXTÉRIEUR et loin des fenêtres, des portes et des évents.
Usar un generador en el interior PUEDE MATARLO EN POCOS MINUTOS.
Los gases de escape del generador contienen monóxido de carbono. Es un veneno
que no puede verse ni olerse.
NUNCA lo use dentro de su hogar o del garaje, INCLUSO con las puertas y las
ventanas abiertas.
Sólo utilícelo AL AIRE LIBRE y lejos de ventanas, puertas y respiraderos.
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a
poison you cannot see or smell.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents.
8 — English
ELECTRICAL
EXTENSION CORD CABLE SIZE
Refer to the table below to ensure the cable size of the extension cords you use are capable of carrying the required load.
Inadequate size cables can cause a voltage drop, which can burn out the appliance and overheat the cord.
Current in
Amperes
Load in Watts Maximum Allowable Cord Length
At 120V At 240V #8 Wire #10 Wire #12 Wire #14 Wire #16 Wire
2.5 300 600 1000 ft. 600 ft. 375 ft. 250 ft.
5 600 1200 500 ft. 300 ft. 200 ft. 125 ft.
7.5 900 1800 350 ft. 200 ft. 125 ft. 100 ft.
10 1200 2400 250 ft. 150 ft. 100 ft. 50 ft.
15 1800 3600 150 ft. 100 ft. 65 ft.
20 2400 4800 175 ft. 125 ft. 75 ft.
25 3000 6000 150 ft. 100 ft.
30 3600 7200 125 ft. 65 ft.
40 4800 9600 90 ft.
ELECTRIC MOTOR LOADS
It is characteristic of common electric motors in normal operation to draw up to six times their running current while starting.
This table may be used to estimate the watts required to start electric motors; however, if an electric motor fails to start or
reach running speed, turn off the appliance or tool immediately to avoid equipment damage. Always check the requirements
of the tool or appliance being used compared to the rated output of the generator.
Motor Size (H.P.) Running Watts
Watts Required to Start Motor
Universal Capacitor Split Phase
1/8 275 N/A 850 1200
1/6 275 600 850 2050
1/4 400 800 1050 2400
1/3 450 950 1350 2700
1/2 600 1000 1800 3600
3/4 850 1200 2600
1 1100 N/A 3300
NOTICE:
Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them
into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation,
and +/- 3 hz frequency variation from the generator name plate ratings. To avoid damage, always have an additional
load plugged into the generator if solid state equipment (such as a television set) is used. A power line conditioner is
recommended for some solid state applications.
9 — English
ELECTRICAL
GENERATOR CAPACITY
Make sure the generator can supply enough continuous (run-
ning) and surge (starting) watts for the items you will power
at the same time. Follow these simple steps.
1. Select the items you will power at the same time.
2. Total the continuous (running) watts of these items. This
is the amount of power the generator must produce to
keep the items running. See the wattage reference chart
at right.
3. Estimate how many surge (starting) watts you will need.
Surge wattage is the short burst of power needed to
start electric motor-driven tools or appliances such as a
circular saw or refrigerator. Because not all motors start
at the same time, total surge watts can be estimated by
adding only the item(s) with the highest additional surge
watts to the total rated watts from step 2.
Example:
Tool or Appliance
Running
Watts*
Starting
Watts*
Window AC,
10,000 BTU
1200 1800
Refrigerator 700 2200
1/3 HP Well Pump 1000 2000
27 in. Television 500 0
Light (75 Watts) 75 0
3475 Total
Running Watts
2200 Highest
Starting Watts
Total Running Watts 3475
Highest Starting Watts + 2200
Total Starting Watts Needed 5675
POWER MANAGEMENT
To prolong the life of the generator and attached devices,
it is important to take care when adding electrical loads to
the generator. There should be nothing connected to the
generator outlets before starting its engine. The correct and
safe way to manage generator power is to sequentially add
loads as follows:
1. With nothing connected to the generator, start the engine
as described later in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity. Take
special care to consider surge loads in generator capacity
as previously described.
NOTICE:
Do not overload the generator’s capacity. Exceeding the
generator’s wattage/amperage capacity may damage the
generator and/or electrical devices connected to it.
Application/Equipment
Estimated
Run Watts
Estimated
Starting
Watts
Emergency / Home Standby
Clock Radio 50 50
Lights (qty. 4 x 75 W) 300 300
Refrigerator 700 2200
Furnace Fan 800 2350
Water Well Pump 1000 1500
Microwave 1000 1000
Sump Pump 1050 2200
Electric Range (per element) 2100 2100
Job Site
Electric Drill ¢ 1/2 HP 600 900
Airless Sprayer ¢ 1/3 HP 600 1200
Quartz Halogen Work Light 1000 1000
Reciprocating Saw 960 1920
Air Compressor ¢ 1 HP 1600 4500
Circular Saw ¢ 7-1/4 in. 1400 2300
Planer/.ointer ¢ 6 in 1800 1800
Miter Saw ¢ 10 in. 1800 1800
Table Saw/Radial Arm Saw ¢ 10 in. 2000 2000
*Wattages listed are approximate. Check tool or appliance for actual wattage.
10 — English
PRODUCT SPECIFICATIONS
ENGINE
Engine Type .........................................GX390, 389cc, OHV
Fuel Volume ................................................................ 8 gal.
GENERATOR
Rated Voltage .....................................................120V/240V
Rated Amps ..................................................... 62.5A/31.3A
Rated Running Watts* .............................................7500 W
Rated Starting Watts ...............................................9375 W
Rated Frequency ........................................................60 Hz
DIMENSIONS
Length ........................................................................ 32 in.
Width .......................................................................... 20 in.
Height ......................................................................... 24 in.
Weight .................................................................... 221 lbs.
KNOW YOUR GENERATOR
See Figure 1.
The safe use of this product requires an understanding of the
information on the product and in this operator’s manual as
well as a knowledge of the project you are attempting. Before
use of this product, familiarize yourself with all operating
features and safety rules.
AC CIRCUIT BREAKERS
The circuit breakers are provided to protect the generator
against electrical overload. The circuit breaker may be reset
by pressing the circuit breaker reset button.
AIR FILTER
The air filter helps to limit the amount of dirt and dust drawn
into the unit during operation.
ANALOG HOUR METER
The analog hour meter operates whenever the engine is
running and keeps track of how many hours the unit has
been used.
CHOKE
The choke is used when starting a cold engine.
ENGINE SWITCH
The engine switch is used either alone or in combination
with the recoil starter grip to start the generator. To turn the
engine off, place the engine switch in the “OFF” position.
FUEL TANK
The fuel tank has a capacity of 8 gallons.
FUEL VALVE
Fuel flow from the fuel tank to the engine is turned on and
off using the fuel valve.
FUSE
The fuse protects the battery charge circuit from short circuit.
GROUND TERMINAL
The ground terminal is used to assist in properly grounding
the generator to help protect against electrical shock. Consult
with a qualified local electrician for grounding requirements
in your area.
LOW OIL SHUT DOWN PROTECTOR
The low oil sensor causes the engine to stop if the level of
lubricant in the crankcase is insufficient.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the
generator when necessary.
OIL DRAIN PLUG
When changing the engine lubricant, unscrew and remove
the oil drain plug to allow old engine lubricant to be drained.
RECEPTACLES
Your generator has the following single phase, 60 Hz out-
lets: four GFCI 120 Volt AC, 20 Amp receptacles, and one
240 Volt AC, 30 Amp receptacle. These can be used for
operating appropriate appliances, electrical lighting, tools,
and motor loads.
RECOIL STARTER GRIP
The recoil starter grip is used (along with the engine switch)
to start the generator’s engine.
*Rated running watts determined by PGMA Standard G200
FEATURES
11 — English
UNPACKING
This product requires assembly.
Carefully cut the box down the sides then remove the
machine and any accessories from the box. Make sure
that all items listed in the loose parts list are included.
NOTE: This machine is heavy and requires a minimum of
two people to lift. To avoid back injury, lift with your legs
and not your back.
WARNING:
Do not use this product if any parts on the Loose Parts List
are already assembled to your product when you unpack
it. Parts on this list are not assembled to the product by
the manufacturer and require customer installation. Use
of a product that may have been improperly assembled
could result in serious personal injury.
Inspect the unit carefully to make sure no damage
occurred during shipping.
Do not discard the packing material until you have carefully
inspected and satisfactorily operated the product.
If any parts are damaged or missing, please call
1-920-756-4688 for assistance.
WARNING:
If any parts are damaged or missing do not operate
this product until the parts are replaced. Use of this
product with damaged or missing parts could result in
serious personal injury.
WARNING:
Do not attempt to modify this product or create
accessories not recommended for use with this product.
Any such alteration or modification is misuse and could
result in a hazardous condition leading to possible serious
personal injury.
WARNING:
Do not attempt to operate the generator until assembly
is complete. Failure to comply could result in possible
serious personal injury.
LOOSE PARTS LIST
See Figure 2.
The following items are included with the generator:
Key
No. Description Qty.
1 Axle ......................................................................2
2 Washer (3/8 in.) ....................................................2
3 Hitch Pin ..............................................................2
4 Wheel ...................................................................2
5 Handle Lock Pin ..................................................2
6 Lanyard ................................................................2
7 Washer (M6) .........................................................6
8 Bolt (M6 x 25mm) ................................................4
9 Frame Support ....................................................1
10 Lock Nut (M6) ......................................................2
11 Rubber Foot ........................................................2
12 Nut (M5) ...............................................................2
13 Washer (M5) .........................................................2
14 Bolt (M5) ..............................................................2
15 Engine Lubricant..................................................1
Operator’s Manual (not shown) ...........................1
TOOLS NEEDED
See Figure 3.
The following tools (not included or drawn to scale) are
needed for assembly:
Socket Wrench
Combination Wrench
Phillips Screwdriver
NOTE: Do not put fuel or lubricant in the generator before
installing the feet, frame support, wheels and handle.
INSTALLING FEET ON THE FRAME SUPPORT
See Figure 4.
Locate the following items:
Frame support
2 rubber feet
2 lock nuts (M6)
4 washers (M6)
2 bolt (M6 x 25mm)
Place washer onto bolt, then insert bolt through foot and
frame support as shown.
Thread washer over the bolt, then install nut. Tighten nut
securely.
NOTE: Be careful not to overtighten so that foot material
collapses.
Repeat with remaining foot.
ASSEMBLY
12 — English
INSTALLING THE FRAME SUPPORT
See Figure 4.
Install the frame support on the bottom of the generator
frame on the same side as the handle.
Locate the following items:
Frame support with foot
2 washers (M6)
2 bolts (M6 x 25mm)
Raise the end of the generator where the recoil starter is
located high enough to gain access to the frame bottom;
securely position props underneath to support.
Align the holes on the frame support with the holes on
the generator frame.
Slide a washer on the bolt, then insert the bolt through
the hole in the generator frame and through the
frame
support.
Thread bolt through hole in frame support with foot and
tighten securely.
Repeat on other side.
INSTALLING THE WHEELS
See Figure 5.
Wheels are provided to assist in moving the generator to
the desired location and should be installed on the side
opposite the handle.
Locate the following items:
2 axles
2 hitch pins
2 washers (3/8 in.)
2 wheels
Raise the end of the generator where the recoil starter is
located high enough to gain access to the frame bottom;
securely position props underneath to support.
Slide the axle through the hole in the center of the wheel.
Slide a washer onto the axle, then slide the axle into the
wheel mounting hole as shown.
Insert hitch pin to secure.
NOTE: The hitch pin should be pushed into the axle until
the center of the pin rests on top of the axle.
Repeat with the second wheel.
LOCKING THE HANDLES
See Figures 6 - 7.
Locate the following items:
2 handle lock pins
2 lanyards
Attach the lanyard to the handle lock pin and the handle
as shown in figure 6.
Extend the handle, then insert the pin through the hole
in the handle and the generator frame to secure handle
in place.
Repeat the process on the other side to lock the other
handle.
CAUTION:
Do not attempt to lift the unit by the handle assembly. If
it is necessary to lift the generator, always grasp by the
frame. Use proper lifting techniques to avoid back injury.
RELEASING THE HANDLES
Remove the handle lock pins and lower the handles to
the down position.
CONNECTING/DISCONNECTING BATTERY
See Figure 8.
WARNING:
To reduce the risk of electrocution or explosion, do not
short circuit the battery terminals or charge in a sealed
container. Keep sparks and flame away.
WARNING:
Keep metal objects away from the battery terminals.
Metal objects can make a connection from one terminal
to another. Shorting the battery terminals together can
cause sparks, burns, or a fire.
The battery cables must be connected before the electric
start feature of the generator can be operated.
Locate the following items:
2 nuts (M5)
2 washers (M5)
2 bolts (M5)
Align the holes in the battery cables with the holes in the
battery terminals.
Secure the battery cables to the terminals using bolts,
washers, and nuts as shown. Connect the red cable to
the positive (+) terminal first, then connect the black cable
to the negative (–) terminal. Make sure all connections are
tight.
NOTE: Be careful not to short across the terminals when
installing. Shorting the terminals together can cause
sparks, damage to the battery or generator, or even burns
or explosions.
Cover the terminals with the rubber covers.
When removing the battery for replacement: disconnect
the negative (black) post, then the positive (red) post, being
careful not to short across the terminals. Always abide by the
safety warnings provided with the battery. Remove the battery
and dispose of according to local and state regulations.
ASSEMBLY
13 — English
DANGER:
Carbon Monoxide. Using a generator indoors CAN KILL
YOU IN MINUTES.
Generator exhaust contains high levels of carbon mon-
oxide (CO), a poisonous gas you cannot see or smell. If
you can smell the generator exhaust, you are breathing
CO. But even if you cannot smell the exhaust, you could
be breathing CO.
Never use a generator inside homes, garages, crawl-
spaces, or other partly enclosed areas. Deadly levels
of carbon monoxide can build up in these areas. Us-
ing a fan or opening windows and doors does NOT
supply enough fresh air.
ONLY use a generator outdoors and far away from
open windows, doors, and vents. These openings
can pull in generator exhaust.
Even when you use a generator correctly, CO may
leak into the home. ALWAYS use a battery-powered or
battery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator
has been running, move to fresh air RIGHT AWAY. See
a doctor. You could have carbon monoxide poisoning.
DANGER:
If this generator will be used only with cord and plug-con-
nected equipment, National Electric Code does not re-
quire that the unit be grounded. However, other methods
of using the generator may require grounding to reduce
the risk of shock or electrocution. Consult a qualified elec-
trician, electrical inspector, or local agency having juris-
diction for local codes or ordinances to find out if ground-
ing is needed in your situation before using the generator.
WARNING:
Do not allow familiarity with this product to make you
careless. Remember that a careless fraction of a second
is sufficient to inflict serious injury.
WARNING:
Do not use any attachments or accessories not
recommended by the manufacturer of this product. The
use of attachments or accessories not recommended
can result in serious personal injury.
NOTICE:
This product is equipped with a spark arrestor that has
been evaluated by the USDA Forest Service; however,
product users must comply with Federal, State, and lo-
cal fire prevention regulations. Check with appropriate
authorities. Contact customer service to purchase a
replacement spark arrestor.
NOTICE:
Before each use, inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts, caps,
etc. Tighten securely all fasteners and caps and do not
operate this product until all missing or damaged parts
are replaced. Please call 1-920-756-4688 or contact an
authorized service center for assistance.
APPLICATIONS
This generator is designed to supply electrical power for
operating compatible electrical lighting, appliances, tools,
and motor loads.
BEFORE OPERATING THE UNIT
Only use OUTSIDE and far away from windows, doors,
and vents.
NEVER use inside a home or garage, EVEN IF doors and
windows are open.
Always position the generator on a flat firm surface.
SPECIAL REQUIREMENTS:
There may be General or State Occupational Safety and
Health Administration (OSHA) regulations, local codes or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction:
In some areas, generators are required to be registered
with local utility companies.
If the generator is used at a construction site, there may
be additional regulations which must be observed.
CHECKING/ADDING LUBRICANT
See Figure 9.
NOTICE:
Attempting to start the engine before it has been properly
filled with lubricant will result in equipment failure.
Engine lubricant has a major influence on engine perfor-
mance and service life. For general, all-temperature use,
SAE 10W-30 is recommended. Always use a 4-stroke motor
lubricant that meets or exceeds the requirements for API
service classification SJ.
NOTE: Non-detergent or 2-stroke engine lubricants will
damage the engine and should not be used.
Unscrew the oil cap/dipstick and remove.
Wipe dipstick clean and re-seat in hole; do not re-thread.
Remove dipstick again and check lubricant level. Lubri-
cant level should fall between the hatched areas on the
dipstick.
If level is low, add engine lubricant until the fluid level rises
to the upper portion of the dipstick.
Replace and secure the oil cap/dipstick.
OPERATION
14 — English
ELECTRIC START
This generator model is provided with both electric start and
recoil start capabilities. Avoid prolonged cranking, as it can
damage the engine.
The battery provided is a nominal 12 volt sealed recharge-
able lead-acid battery and can be operated in any position
without leakage. It complies with non-spillable battery
regulations. Its convenient size offers a 30% reduction over
conventional batteries.
NOTE: Brand new generators are shipped with the battery
connections disconnected. The positive and negative ter-
minals must be connected to the battery before the Electric
Start feature will work.
For initial battery connection, see Connecting/Disconnect-
ing Battery.
STARTING THE ENGINE
See Figures 10 - 13.
NOTICE:
On a level surface with the engine off, check the lubricant
level before each use of the generator.
NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
Unplug all loads from the generator.
Turn the fuel valve to the ON (I) position.
Pull the choke out to the START position.
NOTE: If engine is warm or the temperature is above
50F, push the choke in to the RUN position.
Put the engine switch in the ON (I) position.
Slide the lock button down and hold the button while
pushing the engine switch to the START position.
NOTE: The battery may require charging before the gen-
erator can be started using only the engine switch. The
generator can be started by pulling the recoil starter grip.
Once the generator is started, the battery will charge as
the unit runs.
The generator can also be started by pulling the recoil
starter grip until the engine runs (a maximum of 6 times).
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place.
Allow the engine to run for 15-30 seconds, then move
the choke to the RUN position.
USING FUEL STABILIZER
Fuel gets old, oxidizes, and breaks down over time. Adding
a fuel stabilizer (not included) extends the usable life of fuel
and helps prevent deposits from forming that can clog the
fuel system. Follow fuel stabilizer manufacturer’s directions
for correct ratio of stabilizer to fuel.
Mix fuel stabilizer and gasoline prior to filling the tank
by using a gas can or other approved fuel container and
shaking gently to combine.
NOTE: To control the amount of fuel stabilizer being added
to the engine, always mix fuel stabilizer with gasoline
before fueling the tank rather than adding fuel stabilizer
directly into the generator’s fuel tank.
Replace and secure the fuel tank cap.
Start and run the engine for at least 5 minutes to allow
stabilizer to treat the entire fuel system.
OXYGENATED FUELS
NOTICE:
Do not use E15 or E85 fuel (or fuel containing greater
than 10% ethanol) in this product. It is a violation of
federal law and will damage the unit and void your
warranty.
Fuel system damage or performance problems resulting
from the use of an oxygenated fuel containing more than
the percentage of oxygenates stated below are not covered
under warranty.
Ethanol. Gasoline containing up to 10% ethanol by volume
(commonly referred to as E10) is acceptable. E15 and E85
are not.
CHECKING/ADDING FUEL
See Figure 10.
WARNING:
Gasoline and its vapors are highly flammable and ex-
plosive. To prevent serious personal injury and property
damage, handle gasoline with care. Keep away from igni-
tion sources, handle outdoors only, do not smoke while
adding fuel, and wipe up spills immediately.
When adding gas to the generator, make sure the unit is sitting
on a flat, level surface. If the engine is hot, let the generator
cool for five minutes before adding gas. ALWAYS fill the fuel
tank outdoors with the machine turned off.
Remove the fuel cap slowly.
Fill the fuel tank to 1 in. below the top of the fuel neck.
Replace and secure the fuel cap.
NOTE: Always use unleaded gasoline with a pump octane
rating of 86 or higher. Never use old, stale, or contaminated
gasoline, and do not use an oil/gas mixture. Do not allow dirt
or water into the fuel tank. Do not use E85 fuel.
OPERATION
15 — English
WARNING:
When servicing, use only identical replacement parts.
Use of any other parts can create a hazard or cause
product damage.
WARNING:
Before inspecting, cleaning, or servicing the machine,
shut off engine, wait for all moving parts to stop, and
disconnect spark plug wire and move it away from spark
plug. Allow 30 minutes of cool down time before perform-
ing any maintenance. Failure to follow these instructions
can result in serious personal injury or property damage.
WARNING:
Periodically inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts, caps,
etc. Tighten securely all fasteners and caps and do not
operate this product until all missing or damaged parts
are replaced. Please call 1-920-756-4688 or contact an
authorized service center for assistance.
GENERAL MAINTENANCE
Keep the generator in a clean and dry environment where it
is not exposed to dust, dirt, moisture, or corrosive vapors.
Do not allow the cooling air slots in the generator to become
clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water
entering the fuel system or other internal parts of the unit can
cause problems that will decrease the life of the generator.
To clean the unit:
Use a soft bristle brush and/or vacuum cleaner to loosen
and remove dirt and debris.
Clean air vents with low pressure air that does not exceed
25 psi.
Wipe the exterior surfaces of the generator with a damp
cloth.
SPARK ARRESTOR
See Figure 14.
NOTICE:
This product is equipped with a spark arrestor that has
been evaluated by the USDA Forest Service; however,
product users must comply with Federal, State, and lo-
cal fire prevention regulations. Check with appropriate
authorities. Contact customer service to purchase a
replacement spark arrestor.
Inspect the spark arrestor for breaks or holes. Replace if
necessary.
Use a brush to remove carbon deposits from the spark
arrestor screen as needed.
CHANGING FUSE
See Figure 15.
The generator contains a 2 Amp fuse to protect the battery
charge circuit from short circuit. To replace the fuse:
NOTICE:
Do not use a higher rated fuse other than the specified
amperage. This could cause damage to the product.
OPERATION
MAINTENANCE
STOPPING THE ENGINE
See Figures 10 - 11.
To stop the engine under normal operating conditions:
Remove any load from the generator.
Turn the fuel valve to the OFF (O) position.
To stop the engine, put the engine switch in the OFF (O)
position.
To stop the engine in an emergency situation:
Put the engine switch in the OFF (O) position.
WARNING:
While operating and storing, keep at least 3 feet of clear-
ance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of “cool down” time
before storage. Heat created by muffler and exhaust
gases could be hot enough to cause serious burns and/
or ignite combustible objects.
HIGH ALTITUDE OPERATION
Specific modifications are needed for high-altitude operation.
Please contact your authorized service center for important
information regarding these modifications. Operating this
engine without the proper altitude modification may increase
the engine’s emissions and decrease fuel economy and
performance.
16 — English
Grip both sides of the plastic fuse holder and twist apart
to reveal the fuse and spring.
Insert new fuse and refasten the fuse holder by pushing
the two sides of the connector together and twisting to
secure.
NOTE: If spring came out of fuse holder when it was
opened, it should also be replaced inside the fuse holder
before securing.
TRANSPORTING
Turn the engine switch OFF (O). Disconnect any equip-
ment that is plugged into the generator.
Turn the fuel valve to the OFF position.
Allow 30 minutes of “cool down” time before storing the
machine. Make sure engine and exhaust of unit is cool.
For security, insert the pins to secure the handles before
transporting.
Tilt the machine away from you until it balances on the
wheels, then roll the machine to the desired location.
If transporting in a vehicle, drain the fuel tank, and se-
curely restrain the generator.
BATTERY REMOVAL AND PREPARATION
FOR RECYCLING
To preserve natural resources, please recycle
or dispose of batteries properly.
This product uses lead acid batteries. Local,
state or federal laws may prohibit disposal of
batteries in ordinary trash.
Consult your local waste authority for information regarding
available recycling and/or disposal options.
WARNING:
Upon removal, cover the battery’s terminals with heavy-
duty adhesive tape. Do not attempt to destroy or disas-
semble battery or remove any of its components. Lead
acid batteries must be recycled or disposed of properly.
Also, never touch both terminals with metal objects and/
or body parts as short circuit may result. Keep away from
children. Failure to comply with these warnings could
result in fire and/or serious injury.
MAINTENANCE
STORAGE
When preparing the generator for storage, allow the unit to cool for 30 minutes then follow the guidelines below.
STORAGE
TIME
PRIOR TO STORING
Less than 2
months
Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances.
2 months to 1
year
Drain fuel from carburetor.
Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances.
1 year or more Drain fuel from the carburetor.
Remove spark plug.
Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances.
Put a tablespoon of engine lubricant into the spark plug cylinder. Turn the engine slowly with the pull
rope to distribute the lubricant.
Reinstall spark plug.
Change engine lubricant.
After removal from storage:
Fill with fresh gasoline.
NOTE: If storing gasoline in suitable container for later use, make sure gasoline has been treated with fuel stabilizer
according to stabilizer manufacturer’s instructions.
1 / 1

Ariens 986061 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues