5019 100 75068
DL 3351, DLHI 3350
1.
Control panel.
2.
Grease filter.
3.
Lighting unit.
4.
Grease filter surround.
5.
Grease filter surround side knobs
(turn 90° to remove the surround).
6.
Grease filter handles
(pull downwards to remove the grease filters).
CONTROL PANEL
REPLACING BULBS
1.
Unplug the appliance or switch off the mains
power supply.
2.
Remove the grease filter surround (turn the
side knobs 90°).
3.
Remove the burn-out bulb
Use 40W max E14 bulbs only.
4.
Remount the grease filter surround.
REMOVING AND WASHING THE GREASE
FILTERS
1.
Unplug the appliance or switch off the mains
power supply.
2.
Remove the dirty grease filter by pulling the
grease filter handles downwards.
3.
After cleaning the grease filter remount in
reverse order, making sure the entire
extraction surface is covered.
FITTING OR RENEWING THE CARBON
FILTER
1.
Unplug the appliance or switch off the mains
power supply.
2.
Remove the grease filter surround (turn the
side knobs 90°).
3. Fitting:
Fit the carbon filter over the motor
protection grille - the reference mark (
a
) on the
edge of the carbon filter should line up with the
arrow on the fan shroud (
b
). Turn clockwise.
Removing:
turn anti-clockwise.
4.
Remount the grease filter surround.
90°90°
2
1
3
4
3
5 5
6 6
1
OO
I
1
O
1
2
3
O
I
A.
Speed selector.
B.
Light switch.
AB AB
small amount of steam and fumes
medium amount of steam and fumes
large amount of steam and fumes
intensive speed (only DLHI 3350)
large amount of steam and fumes
a
a
b
b
DLHI 3350
2 carbon
filters!
DL 3351
1 carbon filter!
a
b
a
PRODUCT DESCRIPTION
SHEET