ELICA EGL436SS Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation

Ce manuel convient également à

GLIDE
Design Team Elica
LI3G8A ed 04/08 printed in Italy
Use, Care, and Installation Guide
Guide dutilisation, dentretien et dinstallation
Guía de instalación, uso y mantenimiento
READ AND SAVE THESE INSTRUCTIONS
LISEZ CES INSTRUCTIONS ET CONSERVEZ-LES
LEA Y GUARDE ESTAS INSTRUCCIONES
EN
Contents page 2
FR
Sommaire page 14
ES
Contenido página 26
English
Contents
Important safety Notice...................................................................................................................................................................3
Electrical & Installation requirements..............................................................................................................................................4
Electrical requirements...............................................................................................................................................................4
Before installing the hood...........................................................................................................................................................4
List of Materials...............................................................................................................................................................................5
Parts supplied ............................................................................................................................................................................5
Parts not supplied ......................................................................................................................................................................5
Dimensions and Clearances ...........................................................................................................................................................6
Ducting Options and Examples.......................................................................................................................................................7
Venting methods ........................................................................................................................................................................7
Preparation ................................................................................................................................................................................7
Installation.......................................................................................................................................................................................8
Description of the hood & Controls ...............................................................................................................................................11
Controls....................................................................................................................................................................................12
Maintenance .................................................................................................................................................................................13
Cleaning...................................................................................................................................................................................13
Grease Filter ............................................................................................................................................................................13
Replacing the light bulb............................................................................................................................................................13
APPROVED FOR RESIDENTIAL APPLIANCES
FOR RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Safety Warning: Turn off power circuit at service panel and lock out panel, before wiring this appliance.
Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit
3
READ AND SAVE THESE INSTRUCTIONS
Important safety Notice
CAUTION
FOR GENERAL VENTILATING USE ONLY. DO NOT USE
TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS OR VAPOURS.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
B. Before servicing or cleaning the unit, switch power off at
service panel and lock service panel disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
C. Installation Work and Electrical Wiring Must Be Done By
Qualified Person(s) In Accordance With All Applicable
Codes & Standards, Including Fire-rated Construction.
D. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (Chimney) of fuel
burning equipment to prevent back- drafting. Follow the
heating equipment manufacturers guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), the American Society for
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
E. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
F. Ducted systems must always be vented to the outdoors.
CAUTION
To reduce risk of fire and to properly exhaust air, be
sure to duct air outside - do not vent exhaust air into
spaces within walls, ceilings, attics, crawl spaces, or
garages.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCT WORK.
Install this hood in accordance with all requirements
specified.
WARNING
To Reduce The Risk Of Fire Or Electric Shock, Do Not
Use This Hood With Any External Solid State Speed
Control Device.
WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE.
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (I.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS, IN
THE EVENT OF A RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or other metal tray, then turn off the gas burner or the
electric element. BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - you may be burned.
c) DO NOT USE WATER, including wet dishcloths or
towels - a violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a class ABC extinguisher, and you
already know how to operate it.
2) The fire is small and contained in the area where it
started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit.
OPERATION
a. Always leave safety grills and filters in place. Without
these components, operating blowers could catch onto hair,
fingers and loose clothing.
The manufacturer declines all responsibility in the event of
failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The
manufacturer further declines all responsibility for injury due
to negligence and the warranty of the unit automatically
expires due to improper maintenance.
4
Electrical & Installation requirements
Electrical requirements
IMPORTANT
Observe all governing codes and ordinances.
It is the customer’s responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70
— latest edition*, or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No.0-M91 - latest
edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure range
hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
IMPORTANT
Save Installation Instructions for electrical inspector’s use.
The range hood must be connected with copper wire only.
The range hood should be connected directly to the fused
disconnect (Or circuit breaker) box through metal electrical
conduit.
Wire sizes must conform to the requirements of the National
Electrical Code ANSI/NFPA 70 — latest edition*, or CSA
Standards C22.1-94, Canadian Electrical Code Part 1 and
C22.2 No. 0-M91 - latest edition** and all local codes and
ordinances.
A U.L.- or C.S.A.-listed conduit connector must be provided
at each end of the power supply conduit (at the range hood
and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association Batterymarch Park Quincy,
Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road Cleveland,
Ohio 44131-5575
Before installing the hood
1. For the most efficient air flow exhaust, use a straight run
or as few elbows as possible.
CAUTION: Vent unit to outside of building, only.
2. At least two people are necessary for installation.
3. Fittings material is provided to secure the hood to most
types of walls/ceilings, consult a Qualified Installer,
check if they perfectly fit with your cabinet/wall.
4. Do not use flex ducting.
5. COLD WEATHER installations should have an additional
backdraft damper installed to minimize backward cold air
flow and a nonmetallic thermal break to minimize
conduction of outside temperatures as part of the
ductwork. The damper should be on the cold air side of
the thermal break.
The break should be as close as possible to where the
ducting enters the heated portion of the house.
6. Make up air: Local building codes may require the use of
Make-Up Air Systems when using Ducted Ventilation
Systems greater than specified CFM of air movement.
The specified CFM varies from locale to locale. Consult
your HVAC professional for specific requirements in your
area.
5
List of Materials
Parts supplied
• Blower unit housing
• Hood canopy
Stainless steel mesh filter
Halogen light bulb x 2
• Hardware Packet:
Transition
Allen Wrench
Lower bracket x 2
Upper Bracket x 2
Use, Care and Installation Guide
Template
Cloth
2,9x9,5 screws x 2 (To attach the transition)
4,5x16 screws x 4 (2 to attach the drawer to the bottom
of the cabinet + 2 to attach the deflector on top of the
cabinet ceiling)
5x18 screws x 4 (Upper/lower brackets adjusting screws)
3,5x9,5 x 4 (For definitive attaching of upper/lower
brackets).
Parts not supplied
Duct, conduit and all tools required for installation.
• Remote Control
Ductless Recirculating Kit
To be used only in the Ductless (Recirculating)
version
includes: charcoal filter, charcoal filter support and
fixing bracket, deflector
6
Dimensions and Clearances
7
Ducting Options and Examples
Closely follow the instructions set out in this manual.
All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this
manual, is declined.
Venting methods
The hood is equipped with a transition B for discharge of fumes to the outside (Ducting version).
Should it not be possible to discharge cooking fumes and vapour to the outside, the hood can be used in the Ductless
(Recirculating) version. Attach a charcoal filter on the internal side of the metal filter and the deflector F directly on the
transition (Cabinet without ceiling) or at the top of the cabinet. Fumes and vapors are recycled directly through the deflector F
(Cabinet without ceiling) or by means of a duct connected to the transition B and the deflector F.
NOTE: For ductless (Recirculating) version only: purchase the Ductless Recirculating Kit.
Minimum Duct Size (Ducting/Ductless version): 6" Round Pipe.
Preparation
This hood is designed to be installed inside a cabinet (only Blower unit housing) and fixed at the bottom of the cabinet, check
that the cabinet, its bottom, the hanging system of the cabinet and the wall where cabinet is installed is strong enough to support
the hood.
The inside of the cabinet should be accessible.
However, a qualified technician must verify suitability of the materials in accordance with the type of cabinet.
We suggest to mount the cabinet onto the wall after having installed the hood.
Before making cutouts, make sure there is proper clearance.
NOTE: For ductless (recirculating) version only: Check that there is enough clearance from ceiling and deflector once
this last has been mounted to let an easy recirculation of air.
Hood installation height above cooktop is the users preference. The lower the hood is above the cooktop, the more efficient the
capturing of cooking odors, grease and smoke.
CAUTION: FOR GAS RANGES INSTALLATION: MOUNT THIS HOOD SO THAT THE BOTTOM EDGE IS NOT LESS
THAN 24" (61 CM) ABOVE THE COOKING SURFACE.
FOR ELECTRIC RANGES INSTALLATION: MOUNT THIS HOOD SO THAT THE BOTTOM EDGE IS NOT LESS THAN 32"
(81 cm) ABOVE THE COOKING SURFACE.
Check your ceiling height and the hood height maximum before you select your hood.
8
Installation
1. If possible, disconnect and move freestanding or slide-in
range from cabinet opening to provide easier access to
rear wall. Otherwise put a thick, protective covering over
countertop, cooktop or range to protect from damage
and debris. Select a flat surface for assembling the unit.
Cover that surface with a protective covering and place
all canopy hood parts and hardware in it.
2. Remove the metal filter (see paragraph "Maintenance")
top access the inside of the range hood.
3. Perform any necessary cutout on cabinet and wall as per
"Dimensions and clearances" paragraph for range hood
mounting and for vent system and conduit passage.
Use the supplied template to perform the cut out on
cabinet.
Tape the template on the bottom of the cabinet, check
that printed arrows match with the front edge of the
cabinet (without considering the cabinet door).
Cut as indicated.
4. Install the vent system before the range hood. See
„Venting methods“ and „Dimensions and
clearance“ paragraphs.
Note - for Ductless - recirculating - installations:
Purchase the Ductless recirculating kit
Cabinet without ceiling:
Vent system is not required.
Cabinet with ceiling:
A 6" section of duct may be required to connect
transition to deflector.
5. Install a conduit long enough to reach the junction box.
Run wires through hole according the National Electrical
Code or CSA Standards and local codes and ordinances.
There must be enough power supply cable from the
fused disconnect (or circuit breaker) box to make the
connection in the hood’s Junction box/es.
Use caulking to seal all openings on wall.
Do Not turn on power until installation is completed.
6. Fit the transition on top of the hood.
7. Regulate the rear spacer to cover the clearance on the
rear side once the hood has been installed (see also
paragraph "Dimensions and clearances") and fix it with
two screws (one per side).
8. Fit the blower unit housing inside the cabinet through the
bottom opening.
Check that fixing springs goes over the bottom panel..
9
9. Apply two brackets (one per side) to the blower unit
housing.........
....... lock in place (check that each bracket , once in
position, is flush to the front side of the blower unit
housing) tighten the side fixing screws (two per brackets)
and, from the inside of the hood, fix with one screw each
then .......
.......apply the two bigger brackets (lower brackets) under
the first two and....
..... tighten securely the two screws on upper brackets,
check that blower housing is now well blocked, then,
from the inside of the hood, fix definitively the lower
brackets with one screw each.
10. Refinish the installation to cabinet with two fixing screws.
For Ductless (recirculating) installations
Cabinet without ceiling ONLY:
Install the deflector (available as an extra kit) on the
transition - snap into place.
11. Connect ducting to transition. Seal with duct tape.
Do not use duct smaller than the transition.
For Ductless - recirculating - installations:
Cabinet with ceiling ONLY:
provide and install a section of duct long enough to
connect hood transition to deflector once this has been
installed onto the cabinet ceiling (the deflector is
available as an extra kit).
10
12. Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST
ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE
MUST BE CONNECTED TO THE GROUNDING WIRE
IN YOUR HOME ELECTRICAL SYSTEM, AND IT
MUST UNDER NO CIRCUMSTANCES BE CUT OR
REMOVED.
Failure to do so can result in death or electrical
shock.
Remove the knockout and the Junction box cover and
install the conduit connector (cULus listed) in junction
box.
Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and ordinances,
in 1/2" conduit from service panel to junction box.
Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
Close and secure junction box cover.
13. For Ductless (recirculating) installations
Install one charcoal filter (available as an extra kit).
14. Check all light bulbs to make sure they are secure in
their sockets.
Turn power (On) in service panel.
Check lights and blower operation.
15. Install filter.
If range hood does not operate:
Check that the circuit breaker is not tripped or the house
fuse blown.
Disconnect power supply. Check that wiring is correct.
11
Description of the hood & Controls
1 Control panel
2 Grease filter
3 Grease filter release handle
4 Halogen lamp (position and nr. of lamps may vary)
5 Sliding Glass
6 Hood canopy
12
Controls
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
Description of control panel
AB CDE F
A - Lighting: dim lighting / full lighting /off (loop control) -
Works even with hood in stand by and/or drawer closed.
B - Set Fan in Stand by (LED on the lower side of the
display ON).
C - ON/OFF Timer for selected speed (visualizes the speed
selected and flashing LED on the lower side of the
display).
This knob permits the operation of the cooker hood for
a established period:
20 minutes if the speed selected is 1
15 minutes if the speed selected is 2
10 minutes if the speed selected is 3
5 minutes if the boost speed P is selected.
D - Display showing: fan speed (1-2-3-P), filter saturation
indicator (F for metal filter, C for charcoal filter)
Note: if in posses of the Remote Control (see paragraph
"List of Part and Accessories") the display shows a
flashing "b" this to indicate that the remote control
battery must be replaced.
When the led in the lower right side is on, it indicates
that the cooker hood is ready for operation (“standby”
position), the flashing LED indicates that the timer has
been activated for selected speed.
Warning!
The Charcoal filter saturation function is not activated.
In order to activate the charcoal filter saturation
indicator, press buttons E and F simultaneously for 3
seconds. Initially, only letter F will be displayed, then
after the 3 seconds have passed, letter C will be
displayed as well, indicating that the carbon filter
saturation control system is active.
To switch off the system, re-press the same two buttons:
letter C appear on display and after 3 seconds it
disappears and the device will be switched off.
E - Knob to decrease the speed: from boost speed P to
speed level 1.
F - Knob to increase (standby) speed to boost speed P.
Attention! Boost speed P lasts 5 minutes after which the
cooker hood automatically sets the speed to level 2
(suction power).
Controlling the range hood with sliding glass:
Closing the glass, all selected speed and lights switched off.
Hood retains last speed (except P-boost-speed) setting
when glass is closed and re-opened.
If the hood fails to operate correctly, briefly disconnect it
from the mains power supply for almost 5 sec. by pulling out
the plug. Then plug it in again and try once more before
contacting the Technical Assistance Service.
Warning!
Always press the fan off button A before disconnecting the
hood from the mains supply.
Reset filter saturation signal
Press knob B for about 3 seconds.
The letter F and/or C will disappear from the display.
13
Maintenance
ATTENTION! Before performing any maintenance operation, isolate the hood from the electrical supply by switching off at the
connector and removing the connector fuse.
Or if the appliance has been connected through a plug and socket, then the plug must be removed from the socket.
Cleaning
The cooker hood should be cleaned regularly (at least with
the same frequency with which you carry out maintenance
of the fat filters) internally and externally. Clean using the
cloth dampened with neutral liquid detergent. Do not use
abrasive products. DO NOT USE ALCOHOL!
WARNING:
Failure to carry out the basic cleaning recommendations of
the cooker hood and replacement of the filters may cause
fire risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any damage
to the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.
Grease Filter
Traps cooking grease particles.
The filters should be washed frequently using non
aggressive detergents, either by hand or in the dishwasher,
which must be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease filter may
discolour slightly, but this does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.
Replacing the light bulb
Disconnect the hood from the electricity.
Warning! Prior to touching the light bulbs ensure they are
cooled down.
Use a small screwdriver as a lever on the borders of the
lamp in order to remove the lightbulb.
Slide out the lightbulb to be replaced and replace with a
new 12V 20W 30° Ø35 12V GU4.
Carry out the replacement and mount the new lightbulb
by following instructions in the reverse.
If the lights do not work, make sure that the lamps are fitted
properly into their housings before you call for technical
assistance.
14
French
Sommaire
Avis de sécurité important.............................................................................................................................................................15
Exigences électriques et exigences d’installation .........................................................................................................................16
Exigences électriques ..............................................................................................................................................................16
Avant d’installer la hotte...........................................................................................................................................................16
Liste des pièces ............................................................................................................................................................................17
Pièces fournies ........................................................................................................................................................................17
Pièces non fournies..................................................................................................................................................................17
Dimensions et Dégagement..........................................................................................................................................................18
Exemples et possibilités de positionnement des conduits ............................................................................................................19
Méthodes de ventilation ...........................................................................................................................................................19
Préparation ..............................................................................................................................................................................19
Installation.....................................................................................................................................................................................20
Description de la hotte et des commandes...................................................................................................................................23
Commandes.............................................................................................................................................................................24
Entretien .......................................................................................................................................................................................25
Nettoyage.................................................................................................................................................................................25
Filtre à graisse .........................................................................................................................................................................25
Remplacement des ampoules..................................................................................................................................................25
APPROUVÉ POUR LES APPAREILS DE TYPE RÉSIDENTIEL
POUR UNE UTILISATION RÉSIDENTIELLE SEULEMENT
LISEZ CES INSTRUCTIONS ET CONSERVEZ-LES
VEUILLEZ LIRE CES INSTRUCTIONS AU COMPLET AVANT DE COMMENCER.
L’INSTALLATION DE L’APPAREIL DOIT RESPECTER TOUS LES CODES EN VIGUEUR.
IMPORTANT : Conservez ces instructions afin de pouvoir les remettre à l’inspecteur-électricien de votre
région.
INSTALLATEUR : Veuillez laisser ces instructions avec l’appareil pour le propriétaire.
PROPRIÉTAIRE : Veuillez conserver ces instructions pour pouvoir vous y référer plus tard.
Avertissement de sécurité : Coupez l’alimentation du circuit dans le panneau électrique et verrouillez le
panneau avant de raccorder les fils de cet appareil.
Exigence : 120 V c.a., 60 Hz circuit de dérivation de 15 V c.a., 20 Hz, de 15 ou 20 A.
15
LISEZ CES INSTRUCTIONS ET
CONSERVEZ-LES
Avis de sécurité important
ATTENTION
UTILISER CET APPAREIL À DES FINS DE VENTILATION
GÉNÉRALE SEULEMENT. NE PAS
UTILISER CET
APPAREIL POUR ÉVACUER DES MATÉRIAUX OU DES
VAPEURS DANGEREUX OU EXPLOSIFS.
AVERTISSEMENT
POUR RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC
ÉLECTRIQUE ET DE BLESSURE, RESPECTER LES
DIRECTIVES SUIVANTES :
A. Utiliser cet appareil uniquement aux fins prévues par le
fabricant. Si vous avez des questions à propos de l’appareil,
communiquez avec le fabricant.
B. Avant de faire l’entretien de l’appareil ou de le nettoyer,
coupez l’alimentation dans le panneau électrique et
verrouillez le panneau en bloquant le dispositif
permettant d’empêcher d’activer l’alimentation
accidentellement. S’il n’est pas possible de verrouiller
l’accès au panneau, fixez une étiquette très voyante au
panneau électrique.
C. Une personne qualifiée doit effectuer l’installation et le
câblage des fils électriques en conformité avec tous les
codes et toutes les normes, y compris la cote de
résistance au feu.
D. Il est important de prévoir suffisamment d’air pour
assurer une bonne combustion de l’équipement de
chauffe et l’évacuation adéquates des gaz par le conduit
de cheminé afin de prévenir les refoulements d’air.
Respectez les directives et les normes de sécurité des
fabricants de l’équipement de chauffage, comme celles
publiées par la National Fire Protection Association
(NFPA), la American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) et le code
des autorités de votre région.
E. Au moment de couper ou de percer un mur ou un
plafond, assurez-vous de ne pas endommager la filerie
électrique ou tout autre accès à un service publique.
F. Il faut toujours évacuer à l’extérieur les systèmes à
conduit.
ATTENTION
Pour réduire les risques d’incendie et évacuer l’air
correctement, assurez-vous que le conduit mène à
l’extérieur; il ne faut pas évacuer l’air dans l’espace
entre les murs, dans les plafonds, dans les greniers, les
vides sanitaires ou les garages.
AVERTISSEMENT
POUR RÉDUIRE DES RISQUES D’INCENDIE, UTILISEZ
UNIQUEMENT DES CONDUITS EN MÉTAL.
Installez cette hotte en respectant toutes les exigences
mentionnées.
AVERTISSEMENT
Pour réduire les risques d’incendie et de choc
électrique, n’utilisez pas cette hotte avec un contrôleur
de vitesse à semi-conducteurs.
AVERTISSEMENT
POUR RÉDUIRE LES RISQUES D’INCENDIE DE
GRAISSE SUR LES CUISINIÈRES.
a) Ne laissez jamais la cuisinière sans surveillance
lorsqu’elle est réglée à une haute température. Les
débordements par bouillonnement causent de la fumée
et des débordements de gras qui peuvent s’enflammer.
Faites chauffer l’huile lentement, à une température
basse ou moyenne.
b) Faites toujours fonctionner la hotte lorsque vous utilisez
la cuisinière à une haute température ou que vous faites
flamber des aliments (P. ex. : crêpes Suzette, cerises
jubilées, bœuf au poivre flambé).
c) Nettoyez les hélices de ventilation fréquemment. Il ne
faut pas que la graisse s’accumule sur les filres ou les
hélices.
d) Utilisez le bon format de casserole. Utilisez toujours un
chaudron de taille approprié à l’élément de la cuisinière.
AVERTISSEMENT
POUR ÉVITER DE BLESSER QUELQU’UN LORS D’UN
INCENDIE DE GRAISSE SUR LA CUISINIÈRE, SUIVRE
LES CONSEILS SUIVANTS :
a) ÉTOUFFER LES FLAMMES avec un couvercle aux
dimensions de la taque de cuisson, une tôle à biscuit ou
tout autre plateau métallique, puis couper le gaz ou
l’alimentation électrique de la cuisinière. FAIRE
ATTENTION A NE PAS SE BRÛLER. Si les flammes ne
s’éteignent pas immédiatement, QUITTER LA PIÈCE ET
APPELER LES POMPIERS.
b) NE JAMAIS PRENDRE EN MAIN UNE CASSEROLE
EN FEU, vous pourriez vous blesser.
c) NE PAS UTILISER D’EAU, y compris les essuies de
vaisselle ou les serviettes humides – une violente
explosion due à la vapeur formée pourrait survenir.
d) Utiliser un extincteur SEULEMENT si:
1) Vous êtes sûr d’avoir un extincteur de classe ABC que
vous savez utiliser.
2) Le feu est petit et confiné à la zone où il s’est formé.
3) Les pompiers ont été appelés.
4) Vous pouvez lutter contre le feu avec une sortie
derrière vous.
MODE OPéRATOIRE
a. Toujours laisser les grilles de sécurité et les filtres à leur
place. Sans la présence de ces derniers, les parties
aspirantes pourraient attirer les cheveux, les doigts ou
les vêtements.
Le fabricant décline toute responsabilité si les informations
détaillées dans ce manuel pour l’installation, l’entretien et
l’utilisation adéquate du produit ne sont pas observées. Le
fabriquant décline en outre toute responsabilité pour
d’éventuelles blessures dues à des négligences; en outre, la
garantie de l’appareil sera annulée suite à des conditions
d’entretien inappropriées. Cet appareil est fabriqué pour un
usage interne. Ne pas utiliser cet appareil à l’extérieur.
16
Exigences électriques et exigences d’installation
Exigences électriques
IMPORTANT
Respectez tous les codes et les ordonnances en vigueur.
Le client a la responsabilité de :
Contacter un électricien-installateur.
Vérifier que l’installation électrique est adéquate et
conforme avec le Code national de l’électricité, ANSI/NFPA
70 (la plus récente édition*), ou les normes C22.1-94, Code
canadien de l’électricité, Partie 1 et C22.2 No.0-M91
(La plus récente édition**) de la CSA, ainsi que tous les
codes et les ordonnances de votre région.
Si le code le permet et que vous utilisez un fil de mise à la
terre distinct, il est recommandé de faire vérifier le chemin
du fil par un électricien.
Ne pas mettre l’appareil à la terre sur une conduite de gaz.
Consultez un électricien qualifié si vous n’êtes pas certain
que la hotte est mise à la terre correctement.
N’installez pas un fusible dans le circuit neutre ou le circuit
de mise à la terre.
IMPORTANT
Conservez ces instructions afin de pouvoir les remettre à
l’inspecteur-électricien.
La hotte doit être câblée uniquement à l’aide de fils de
cuivre.
Il faut raccorder la hotte directement à une boîte à fusible ou
à un disjoncteur par l’entremise d’une canalisation
électrique en métal.
Le calibre de fil doit être conforme aux exigences du Code
national de l’électricité, ANSI/NFPA 70 (La plus récente
édition*), ou les normes C22.1-94, Code canadien de
l’électricité, Partie 1 et C22.2 0-M91 (La plus récente
édition**) de la CSA, ainsi que tous les codes et les
ordonnances de votre région.
Il faut prévoir un connecteur de canalisation approuvé par
l’UL ou la CSA à chaque extrémité de la canalisation
d’alimentation (À la hotte et à la boîte de jonction).
Vous pouvez obtenir un exemplaire des normes indiquées en vous
adressant à :
* La National Fire Protection Association, Batterymarch Park Quincy,
Massachusetts, 02269
** La CSA International, 8501 East Pleasant Valley Road,
Cleveland, Ohio, 44131-5575
Avant d’installer la hotte
1. Pour assurer la ventilation la plus efficace possible,
installez la conduite en ligne droite ou avec le moins de
coudes possibles.
ATTENTION : La sortie de la conduite de ventilation
doit donner sur l’extérieur.
2. Deux personnes sont nécessaires pour effectuer
l’installation.
3. La quincaillerie fournie permet de fixer la hotte à la
plupart des murs et des plafonds; consultez un
installateur qualifié pour vous assurer que la quincaillerie
fournie est adaptée à votre type de mur ou d’armoire.
4. N’utilisez pas de conduit flexible.
5. Dans le cas des endroits sujets aux TEMPÉRATURES
FROIDES, il faut installer un clapet de contre-tirage
supplémentaire afin de minimiser le retour d’air froid et
un isolant thermique non métallique afin de minimiser la
conduction de la température extérieur dans le conduit.
Il faut placer le clapet du côté de l’air froid de l’isolant
thermique.
L’isolant doit être placé le plus près possible de l’endroit
où le conduit entre dans la partie chauffée de la maison.
6. Air d’appoint : Le code du bâtiment de votre région peut
exiger l’utilisation d’un système d’air d’appoint si vous
utilisez un système de ventilation à conduit dont le
mouvement d’air dépasse un certain nombre de CFM.
Le nombre de pi3/min varie d’une région à l’autre.
Consultez un professionnel de CVC pour connaître les
exigences précises de votre région.
17
Liste des pièces
Pièces fournies
Boîtier du ventilateur
Auvent de la hotte
1 filtre métallique
• 2 ampoules halogènes
Paquet de quincaillerie:
Transition
1 tricoise Allen
2 étriers inférieurs
2 étriers supérieurs
Guide d’utilisation, d’entretien et d’installation
Modèle
Chiffon
2 vis de 2,9×9,5 (pour fixer la transition)
4 vis de 4,5×16 (2 pour fixer le tiroir sur la partie
inférieure du meuble + 2 (pour fixer le déflecteur)
4 vis de 5x18 (Vis de réglage)
4 vis de 3,5x9,5 (vis de fixation des étriers inférieurs et
supérieurs)
Pièces non fournies
Conduit, canalisation et tous les outils nécessaires à
l’installation.
• TÉLÉCOMMANDE
Trousse de conversion en hotte à recyclage
à utiliser seulement avec la version sans conduit (à
recyclage)
comprend : filtre au charbon, soutien de filtre au
charbon et support de fixation, déflecteur
18
Dimensions et Dégagement
19
Exemples et possibilités de positionnement des conduits
Suivez à la lettre les directives présentées dans ce manuel.
Le fabricant refuse toute responsabilité en ce qui a trait à tout préjudice, dommage ou incendie causé par la non observation
des directives contenues dans le présent manuel.
Méthodes de ventilation
La hotte est dotée d’une transition B afin d’évacuer les vapeurs à l’extérieur (Version à conduit).
S’il s’avère impossible d’évacuer la fumée et les vapeurs de cuisson à l’extérieur, il est possible de transformer la hotte en
version sans conduit (recyclage). Fixez un filtre à charbon sur le côté interne du filtre en métal et le déflecteur F sur la
transition (meuble sans toit) ou sur la partie supérieure du meuble. Les fumées et les vapeurs sont directement recyclés à
travers le déflecteur F (meuble sans toit) ou à travers un conduit relié à la transition B et au déflecteur F.
NOTE : dans le cas de la version sans conduit (À recyclage) seulement : procurez-vous la trousse de conversion en
hotte à recyclage.
Diamètre minimum des conduit (Version avec ou sans conduit) : tuyau rond de 6".
Préparation
Cette hotte est destinée à être installée à l’intérieur d’un meuble (logement de l’unité de ventilation uniquement) et à être fixée
dans la partie inférieure du meuble. Assurez-vous que le meuble, sa partie inférieure, son système d’accrochage et le mur où il
est installé, soient suffisamment résistants pour supporter la hotte.
L’intérieur de l’appareil devra être accessible.
De toute façon, un technicien qualifié doit vérifier l’appropriation des matériaux en conformité avec le type de meuble.
Nous vous suggérons aussi de monter le meuble sur le mur après avoir installé la hotte.
Avant de faire des découpes, assurez-vous qu’il y ait assez d’espace.
NOTE: Pour la version sans conduit (à recyclage) uniquement : Vérifiez qu’il y ait assez de distance entre plafond et déflecteur
une fois que ce dernier ait été monté pour permettre une bonne circulation d’air.
ous pouvez déterminer vous-même la hauteur à laquelle vous installez la hotte au dessus de la cuisinière. Plus la hotte est près
de la cuisinière, plus elle est efficace à capter les odeurs de cuisson, la graisse et la fumée.
ATTENTION: POUR L INSTALLATION DES CUISINIERES A GAZ: LA DISTANCE ENTRE LE BORD INFERIEUR DE LA
HOTTE ET LE PLAN DE CUISSON NE DÔIT PAS ÊTRE INFERIEURE DE 24" (61 CM).
POUR DES CUISINIERES ELECTRIQUES: LA DISTANCE ENTRE LE BORD INFERIEUR DE LA HOTTE ET LE PLAN DE
CUISSON NE DÔIT PAS ÊTRE INFERIEURE DE 32" (81 cm).
Vérifiez donc la hauteur de votre plafond et la hauteur maximum de la hotte avant de choisir votre modèle de hotte.
20
Installation
1. Si possible, débranchez la cuisinière et déplacez-la afin
d’avoir un meilleur accès au mur arrière. Sinon, placez
une couverture épaisse sur le comptoir et la surface de
cuisson afin de les protéger des dommages et des
saletés. Sélectionnez une surface plane pour assembler
l’appareil. Placez une couverture protectrice sur cette
surface, puis disposez les pièces de l’auvent de la hotte
et la quincaillerie.
2. Enlevez le filtre métallique (voir paragraphe « Entretien »)
pour accéder à la partie interne de la hotte.
3. Effectuez tous les découpes sur le meuble et sur le mur
conformément au paragraphe « Dimensions et
dégagement » pour le montage de la hotte, pour le
système de ventilation et pour le passage du conduit.
Appliquer le gabarit avec du ruban adhésif sur le fond du
placard, contrôler que les flèches imprimées coïncident
avec le bord frontal du placard (sans considérer la porte
du placard).
Percer de la façon indiquée
4. Installez le système de ventilation avant la hotte.
Reportez-vous aux paragraphes « Méthodes de
ventilation » et « Dimensions et dégagement ».
Note pour l’installation de la version sans conduit
(version recyclage) : achetez le kit de montage de la
version sans conduit (version recyclage).
Meuble sans toit :
Le système de ventilation n’est pas exigé.
Meuble avec toit :
Un conduit de 6 po peut être nécessaire pour relier la
transition au déflecteur.
5. Installez un conduit assez long pour rejoindre la boîte de
jonction. Passez les câbles à travers le trou selon le
Code national de l’électricité, ou selon les Standards de
la CSA et avec tous les codes et les ordonnances de
votre région.
Il doit y avoir suffisamment de câble pour réaliser une
connexion depuis l’interrupteur jusqu’à la boîte/s de
jonction de la hotte.
Utilisez du caltafage pour sceller toutes les ouvertures
du mur.
Ne pas mettre en marche avant que l’installation ne soit
complète.
6. Placer la transition sur la partie supérieure de la hotte.
7. Une fois la hotte installée, régler le distancier pour
couvrir l’espace sur le côté postérieur. (voir paragraphe
« Dimensions et dégagement » pour plus de détails) et
fixez-la avec deux vis (un de chaque côté).
9. Installez le logement de l’unité de ventilation à l’intérieur
du meuble à travers l’ouverture inférieure.
Vérifiez que les ressorts de fixation soit bien passés par
la partie inférieure du panneau.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

ELICA EGL436SS Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation
Ce manuel convient également à