Westermo L206-S2-EX Mode d'emploi

Taper
Mode d'emploi
www.westermo.com
Lynx DSS L206-S2-EX
Industrial Ethernet 6-port Device Server Switch
2
6643-22901
3
6643-22901
General information
Legal information
The contents of this document are provided “as is”. Except as required by applicable law,
no warranties of any kind are made in relation to the accuracy and reliability or contents
of this document, either expressed or implied, including but not limited to the implied
warranties of merchantability and fitness for a particular purpose. Westermo reserves
the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or
any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at www.westermo.com
Software tools
Related software tools are available at www.westermo.com/support/software-tools.
License and copyright for included Free/Libre Open Source Software
This product includes software developed by third parties, including Free/Libre Open
Source Software (FLOSS). The specific license terms and copyright associated with the
software are included in each software package respectively. Please visit the product web
page for more information.
Upon request, the applicable source code will be provided. A nominal fee may be charged
to cover shipping and media. Please direct any source code request to your normal sales
or support channel.
WeOS Management Guide
This product runs WeOS (Westermo Operation System). Instructions for quick start,
configuration, factory reset and use of USB port are found in the WeOS Management
Guide at www.westermo.com.
4
6643-22901
Safety and Regulations
Warning signs are provided to prevent personal injuries and/or damages to the product.
The following levels are used:
Level of warning Description Consequence
personal injury
Consequence
material damage
WARNING
Indicates a potentially
hazardous situation
Possible death or
major injury
Major damage to the
product
CAUTION
Indicates a potentially
hazardous situation
Minor or moderate
injury
Moderate damage to
the product
NOTICE
Provides information
in order to avoid
misuse of the
product, confusion or
misunderstanding
No personal injury Minor damage to the
product
NOTE
Used for highlighting
general, but important
information
No personal injury Minor damage to the
product
5
6643-22901
Before installation:
Read this manual completely and gather all information on the product. Make sure that
you understand it fully. Check that your application does not exceed the safe operating
specifications for this product.
WARNING - SAFETY DURING INSTALLATION
The product must be installed by qualified service personnel
and built in to an apparatus cabinet or similar, where access is
restricted to service personnel only.
During installation, ensure a protective earthing conductor is
first connected to the protective earthing terminal (only valid for
metallic housings). Westermo recommends a cross-sectional area
of at least 4 mm2.
If the product does not have a protective earthing terminal, then
the DINrail must be connected to protective earth. Upon removal
of the product, ensure that the protective earthing conductor, or
the connection to earth via the DIN-rail, is disconnected last.
WARNING - PROTECTIVE FUSE
It must be possible to disconnect manually from the power supply.
Ensure compliance to national installation regulations.
Replacing the internal fuse must only be performed by Westermo
qualified personell.
WARNING - HAZARDOUS VOLTAGE
Do not open an energized product. Hazardous voltage may occur
when connected to a power supply.
6
6643-22901
WARNING - REDUCE THE RISK OF FIRE
To reduce the risk of fire, use only telecommunication line cords
with a cable diameter of AWG 26 or larger. Regarding power
cable dimensions, see Interface Specifications.
CAUTION - CORROSIVE GASES
If the product is placed in a corrosive environment, it is important
that all unused connector sockets are protected with a suitable
plug, in order to avoid corrosion attacks on the gold plated
connector pins.
CAUTION - ELECTROSTATIC DISCHARGE (ESD)
Prevent electrostatic discharge damages to internal electronic
parts by discharging your body to a grounding point (e.g. use a
wrist strap).
CAUTION - HOT SURFACE
Be aware of that the surface of this product may become hot.
When it is operated at high temperatures, the external surface
may exceed Touch Temperature Limit according to the product's
relevant electrical safety standard.
WARNING - POWER SUPPLY CONNECTION
There are safety regulations on which power sources that shall
be used in conjunction with the product. Refer to Interface
Specifications.
7
6643-22901
Product disposal
This symbol means that the product shall not be treated
as unsorted municipal waste when disposing of it. It needs
to be handed over to an applicable collection point for
recycling electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will
help to reduce hazardous substances and prevent potential
negative consequences to both environment and human
health, which could be caused by inappropriate disposal.
Care recommendations
Follow the care recommendations below to maintain full operation of product and to
fulfill the warranty obligations:
Do not drop, knock or shake the product. Rough handling above the specification
may cause damage to internal circuit boards.
Use a dry or slightly water-damp cloth to clean the product. Do not use harsh
chemicals, cleaning solvents or strong detergents.
Do not paint the product. Paint can clog the product and prevent proper operation.
If the product is used in a manner not according to specification, the protection provided
by the equipment may be impaired.
If the product is not working properly, contact the place of purchase, nearest Westermo
distributor office or Westermo technical support.
CAUTION - CABLE TEMPERATURE RATING FOR
FIELD TERMINAL WIRES
There may be a requirement on the minimum temperature rating
of the cable to be connected to the field wiring terminals, see
Interface Specifications.
8
6643-22901
ATEX certification
ATEX certification number
Baseefa12ATEX0119X
Standards
EN 60079-0, EN 60079-15
Certification code
Ex nA IIC T3 Gc (–40°C ≤ Ta ≤ +70°C)
ATEX code
II 3G
Specific Conditions of Use
The equipment must be installed in an area of not more than pollution degree 2 in
accordance with IEC/EN 60664-1, and in an enclosure that provides a minimum degree of
protection of at least IP54 and complies with the relevant requirements of EN 60079-0
and EN 60079-15.
All external connections to the equipment and, where applicable, the SFP modules must
not be inserted or removed unless either the area in which the equipment is installed is
known to be non-hazardous, or the circuits connected have been de-energized.
The network cables once installed must be properly fixated by the use of cable ties or
similar to reduce the risk of accidently withdrawing the plugs.
Equipment input parameters
Power Connector: +DC1, +DC2 & –COM
Working Voltage Range = 24 V to 48 VDC.
I/O Connector: ‘Status +’ & ‘Status –’ and ‘Digital in +’ and ‘Digital in –’
Maximum I/P Voltage = 60 VDC.
9
6643-22901
ATEX-Zertifizierung
ATEX-Zulassungsnummer
Baseefa12ATEX0119X
Standards
EN 60079-0, EN 60079-15
Zertifizierungscode
Ex nA IIC T3 Gc (–40°C ≤ Ta ≤ +70°C)
ATEX-Code
II 3G
Spezifische Einsatzbedingungen
Die Geräte müssen in einem Bereich welcher einem maximalen Verschmutzungsgrad der
Stufe 2 gemäß IEC/EN 60664-1 entspricht und in einem Gehäuse, das einen Schutzgrad
von mindestens IP54 bietet und die relevanten Anforderungen von N 60079-0 und EN
60079-15 erfüllt, installiert werden.
Alle äußeren Anschlüsse des Gerätes und auch die SFP-Module dürfen nur dann
verbunden oder getrennt werden, wenn entweder der Bereich, in dem das Gerät
installiert ist, nachweislich ungefährlich ist, oder die verbundenen Stromkreise
spannungsfrei sind.
Die Netzwerkkabel müssen nach der Installation mithilfe von Kabelbindern oder
ähnlichem Material ordnungsgemäß befestigt werden, um ein versehentliches Abziehen
der Stecker zu verhindern.
Eingangsparameter der Geräte
Stromversorgung: +DC1, +DC2 & –COM
Betriebsspannungsbereich = 24 V to 48 VDC.
I/O-Anschluss: ‘Status +’ & ‘Status –’ und ‘Digital in +’ und ‘Digital in –’
Maximale I/P-Spannung = 60 VDC.
10
6643-22901
Certification ATEX
Numéro de certification ATEX
Baseefa12ATEX0119X
Normes
EN 60079-0, EN 60079-15
Code de certification
Ex nA IIC T3 Gc (–40°C ≤ Ta ≤ +70°C)
Code ATEX
II 3G
Conditions spéciales d'utilisation
L'équipement doit être installé dans une zone où le degré de pollution ne dépasse pas le
degré 2 conformément à l'IEC/EN 60664-1, et dans un boîtier qui fournit un niveau de
protection au moins égal à IP54 et conforme aux exigences applicables à EN 60079-0 et
EN 60079-15
Toutes les connexions externes à l'équipement et, le cas échéant, les modules SFP ne
doivent pas être insérés ou retirés sauf si la zone dans laquelle l'équipement est installé
est reconnue comme non dangereuse, ou si les circuits raccordés sont hors-tension.
Une fois les câbles réseau installés, ils doivent être correctement fixé grâce à des attaches
de câbles ou autre élément semblable afin de réduire le risque de débranchement
accidentel.
Paramètres d'entrée des équipements
Connecteur d'alimentation: +DC1, +DC2 & –COM
Double entrée d'alimentation 24V à 48VCC
ConnecteurE/S: «Statut +» et «Statut –» et «Entrée digitale +» et «Entrée digitale –»
Tension maximale I/P = 60 VCC.
11
6643-22901
Agency approvals and standards compliance
Type Approval / Compliance
EMC
EN 61000-6-1, Immproducty residential environments
EN 61000-6-2, Immproducty industrial environments
EN 61000-6-3, Emission residential environments
EN 61000-6-4, Emission industrial environments
EN 50121-4, Railway signalling and telecommunications apparatus
IEC 62236-4, Railway signalling and telecommunications apparatus
Safety
UL 62368-1, Safety Communication Technology
Marine
DNV GL rules for classification – Ships and offshore products
Ex
EN 60079-0 and EN 60079-15
FCC Part 15.105
Notice:
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
… Reorient or relocate the receiving antenna
… Increase the separation between the equipment and receiver
… Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
… Consult the dealer or an experienced radio/TV technician for help.
UL 62368-1
Notice:
This product has been tested and found compliant to UL 62368-1, Safety for
Communication Technology. In accordance with the definitions of the standard, this
product shall be handled by instructed personell. Energy source classifications are
according to following:
Electrical energy source Power port ES1
Serial port ES1
Ethernet port ES1, TNV-1
I/O port ES1
Power source Power port PS3
Thermal energy source Enclosure TS1
Mechanical energy source Enclosure MS1
Radiation energy source SFP RS1
12
6643-22901
Product Description
L206-S2-EX is an industrial switch and device server made for harsh environments.
WeOS is the operating system of L206-S2 enabling the product to operate in two
functional levels. The switch can be used in either 10 or 100 Mbit networks.
L206-S2-EX has two serial ports, one that supports RS-232 and the other configurable
for RS-232/422/485 as well as serial protocols for interconnection with legacy equipment.
Our unique FRNT (Fast Recovery of Network Topology) technology is the fastest
protocol on the market to re-configure a network in the event of any link or hardware
failure. That is why our equipement are used in safety critical applications such as tunnels,
traffic signal control and railway systems.
CAUTION - CORROSIVE GASES
If the product is placed in a corrosive environment, it is important
that all unused connector sockets are protected with a suitable
plug, in order to avoid corrosion attacks on the gold plated
connector pins.
Declaration of Conformity
Hereby, Westermo declares that this product is in compliance with applicable EU
directives. The full EU declaration of conformity and other detailed information is
available at www.westermo.com/support/product-support.
Corrosive
environment
Notice:
This product has been successfully tested in a corrosion test according to IEC 60068-2-
60, method 3. This means that the product meets the requirements to be placed in an
environment classified as ISA-S71.04 class G3.
13
6643-22901
Hardware Overview
Location of interface ports and LEDs
LED Indicators
Power connection
I/O connection
RJ-45 connector (Front view)
Male Female
Pin 8
Pin 1
Pin 1
Pin 8
Pin 8 Pin 1
Ethernet connection TX (4 ports)
Position Signale Direction Description Input/output values
No.1 TD+ In/Out Transmitted/Received data
Per port:
U = ± 1 V (4V/μs)
I = ± 20 mA
Data rate:
10/100 Mbit/s
No. 2 TD– In/Out Transmitted/Received data
No. 3 RD+ In/Out Transmitted/Received data
No. 4 Not Connected
No. 5 Not Connected
No. 6 RD– In/Out Transmitted/Received data
No. 7 Not Connected
No. 8 Not Connected
Shield Connected to PE
Galvanically isolated via signal transformers and capacitively isolated to
GND/PE through a 2kV 1000pF capacitor.
USB
Position Direction* / description Output values
1 Out / VBUS
U
out
= 5 VDC max
I
out
= 400 mA max
2 In/out / D–
3 In/out / D+
4 GND
Shield PE
RS-232, RS-422/485)
14
6643-22901
RS-232
Position Signal Direction Description Input/Output values
No. 1 DSR Out Data Set Ready
U = ±12 V max
I = ±60 mA max
Data rate:
50 bit/s – 115.2 kbit/s
No. 2 DCD Out Data Carrier Detect
No. 3 DTR In Data Terminal Ready
No. 4 SG Signal Ground, not chassis ground
No. 5 RD Out Receive Data
No. 6 TD In Transmit Data
No. 7 CTS Out Clear To Send
No. 8 RTS In Request To Send
RS-422/485 (for more details see below)
Position
Signal
Direction Description Input/Output values
RS-422
(4-wire)
RS-485
(2-wire)
No. 1 T+ T+/R+ Out/In RS-422: Transmit
RS-485: Transmit/Receive
U = 5 V max
I = 250 mA max
Data rate:
50 bit/s – 2 Mbit/s
No. 2 T– T–/R– Out/In RS-422: Transmit
RS-485: Transmit/Receive
No. 3 R– In RS-422: Receive
No. 4
Not used
No. 5
Not used
No. 6 R+ In RS-422: Receive
No. 7 Not used
No. 8 Not used
The product is equipped with internal termination that is configurable through software
in RS-422/485 mode. The following termination schemes are supported:
RS-422
RS-485
When the product is powered-off or during reboot, any internal termination will be
disconnected from the signal lines.
No termination
Rx
Terminate Rx Terminate Tx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Terminate Tx and Rx
No termination
Termination
Note
Due to that the port is configurable for both RS-232 and
RS-422/485, there are no fail-safe biasing available for RS-422/485
signals.
15
6643-22901
Interface specifications
Power
Operating voltage Rated: 24 to 48 VDC
Operating: 19 to 60 VDC
Rated current 150 mA (300 mA) @ 24 VDC (with 500 mA USB load)
80 mA (150 mA) @ 48 VDC (with 500 mA USB load)
Rated frequency DC
Inrush current, I
2
t 22.7·10
-3
A
2
s @ 48 VDC
Startup current* 2 x Rated current
Polarity Reverse polarity protected
Redundant power input Ye s
Isolation to
All other ports
Connection Detachable screw terminal
Conductor cross section 0.2 – 2.5 mm
2
(AWG 24 – 12)
Stripping length cable 7 mm
Tightening torque, terminal screw 0.5 -0.6 Nm
Tightening torque, screw flange 0.3 Nm
Shielded cable Not required
* Recommended external supply current capability for proper start-up
Ethernet TX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type TNV-1
Transmission range Up to 150 m with CAT5e cable or better*
Isolation to All other
Connection RJ-45, auto MDI/MDI-X
Cabling Shielded CAT5e or better is recommended
Conductive housing Ye s
Number of ports 4
* Refer to Safety section.
16
6643-22901
RS-232/422/485
Electrical specification Configurable for EIA RS-232 or EIA RS-422/485
Data rate RS-232 50 bit/s – 115.2 kbit/s
RS-422/485 50 bit/s – 2 Mbit/s
Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
(2 stop bits only when no parity is set)
Circuit type TNV-1
Transmission range RS-232 15 m / 49 ft
RS-422/485 Up to 1200 m / 0.74 mi, depending on data rate and cable
type
Isolation to
All other ports
Connection RS-232 RJ-45 according to EIA-561
RS-422/485 RJ-45
Shielded cable RS-232 Recommended
RS-422/485
Shielded cable not required, except when installed in
Railway application as signalling and telecommunications
apparatus and located close to rails*
Conductive housing Ye s
Number of ports 1
* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and connected to this port.
I/O / Relay output
Maximum voltage/current 60 VDC / 80 mA
Contact resistance Max 30 Ω
Isolation to
All other ports
Connection Detachable screw terminal
Conductor cross section 0.14 – 1.5 mm
2
(AWG 28 – 16)
Stripping length cable 7 mm
Tightening torque, terminal screw 0.22 -0.25 Nm
Tightening torque, screw flange 0.3 Nm
I/O / Digital input
Maximum voltage/load current
60 VDC/2 mA
Voltage levels Logic one: >12V
Logic zero: <1V
Isolation to
All other ports
Connection Detachable screw terminal
Conductor cross section 0.14 – 1.5 mm
2
(AWG 28– 16)
Stripping length cable 7 mm
Tightening torque, terminal screw 0.22 -0.25 Nm
Tightening torque, screw flange 0.3 Nm
17
6643-22901
USB
Electrical specification USB 2.0 host interface
Data rate Up to 12 Mbit/s (full-speed mode)
Circuit type SELV
Maximum supply current
400 mA
Connection USB receptacle connector type A
Console
Electrical specification LVTTL/LVCMOS-level
Data rate 115.2 kbit/s
Data format 8 data bits, no parity, 1 stop bit, no flow control
Circuit type SELV
Connection 2.5 mm jack, use only Westermo cable 1211-2027
18
6643-22901
Type tests and environmental conditions
Environmental phenomena Basic standard Description Test levels
Electrostatic discharge EN 61000-4-2 Enclosure Contact: ±6 kV
Air: ±8 kV
Fast transients EN 61000-4-4 Power port ±2 kV
Ethernet
Status out/Digital in
Serial ports
Enclosure
Surge EN 61000-4-5 Power port
L-E: ±2 kV, 42 Ω, 0.5 μF, 1.2/50 μs
L-L: ±2 kV, 42 Ω, 0.5 μF, 1.2/50 μs
L-E: ±2 kV, 12 Ω, 9 μF, 1.2/50 μs
L-L: ±1 kV, 2 Ω, 18 μF, 1.2/50 μs
Ethernet L-E: ±2 kV, 2Ω, 0.5 μF
Status out/Digital in L-E: ±2 kV, 42 Ω, 0.5 μF
L-L: ±1 kV, 42 Ω, 0.5 μF
RS-232 L-E: ±2 kV, 2 Ω, 0.5 μF
RS-422/485 L-E: ±2 kV, 42 Ω, 0.5 μF
Power frequency magnetic field EN 61000-4-8 Enclosure 300 A/m; 0, 16.7, 60 Hz
1000 A/m; 50 Hz
Pulsed magnetic field EN 61000-4-9 Enclosure 300 A/m
Radiated RF immunity
EN 61000-4-3 Enclosure
20 V/m @ (80 - 2700) MHz
10 V/m @ (2.7 - 6) GHz
1 kHz sine, 80% AM
Conducted RF immunity
EN 61000-4-6 Power port
10 V, 80% AM, 1 kHz; (0.15 - 80) MHz
Ethernet
Status out/Digital in
Serial ports
Earth port
Radiated RF emission CISPR 16-2-3
ANSI C63.4
Enclosure
Class B (Residential), 30 MHz to 6 GHz
FCC Part 15 B, Class B,
30 MHz to 6.5 GHz
Conducted RF emission CISPR 16-2-1
ANSI C63.4
Power port
Class B
Ethernet Class B
Dielectric strength
UL 62368-1
Power port to all
other ports
1.5 kVrms, 50 Hz, 1 min
Ethernet ports to all
other ports
RS-232 port to all
other ports
RS-422/485 port to all
other ports
19
6643-22901
Environmental
Temperatures EN 60068-2-1
EN 60068-2-2
Operating
-40 to +70°C (-40 to +158°F)*
Storage and transport
-50 to +85°C (-58 to +185°F)
Humidity EN 60068-2-30 Operating
5 to 95 % relative humidity
Storage and transport
Altitude Operating
2 000 m/70 kPa
MTBF MIL-C217F2,
Parts count
Ground Benign, 25°C
(77°F)
593,000 hours
Service life Operating
10 years
Vibration IEC 60068-2-6
(sine)
Operating
3 - 13.2 Hz: 1mm
13.2 - 100 Hz: 0.7 g
5.5 - 30 Hz: 1.5 g
30 - 50 Hz: 0.42 mm
50 - 500 Hz: 4.2 g**
IEC 60068-2-64
(random)
5 - 20 Hz: 2 m²/s²,
20 - 2000 Hz: - 3 dB/oct
Shock IEC 60068-2-27 Operating 30 g, 11 ms
100 g, 6 ms**
Bump IEC 60068-2-27 Operating
10 g, 11 ms, x1000
Packaging
Enclosure
UL 62368-1
Zinc Fire enclosure
Dimension W x H x D
With connectors
52.5 x 100 x 101 mm
52.5 x 119 x 101 mm
Weight 0.7 kg
Degree of protection EN 60529 Enclosure IP40
Cooling Convection
* Refer to “Safety” section regarding touch temperature.
** Might require Ethernet cables to be fastened close to the product.
20
6643-22901
Connection to console port
The console port can be used to connect to the CLI
(Command Line Interface).
The following steps needs to be taken
1. Connect the serial diagnostic cable to the console port
(use only Westermo cable 1211-2027).
2. Connect cable to your computer (USB port, if drivers are needed they can be downloaded
from our Web page).
3. Use a terminal emulator and connect with correct speed and format (115200, 8N1)
to the assigned port.
For more information about the CLI, see the WeOS management guide.
I/O connection ) Console port
Cable 1211-2027
Bottom view
Accessories
Description Art no
Westermo console cable 1211-2027
RJ45 to terminal block 1200-2490
RJ45 to DB9 cable 1211-2210
Console Port
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27

Westermo L206-S2-EX Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues