Installation Guide
IND668
Lumination® LED Luminaire
Installation Guide for Direct-Mount / Retrot / Frame-Kit
(LRXB Series)
BEFORE YOU BEGIN / AVANT DE COMMENCER
Read these instructions and IOTA ILB-CP instruction manual completely and carefully.
Wear work gloves to prevent dirt and oil from being transferred to the luminaire.
WARNING / AVERTISSEMENT
RISK OF FIRE OR ELECTRIC SHOCK
Turn power off before inspection, installation or removal.
Install this kit only in the lumiaires that has the construction
features and dimensions shown in the photographs
and/or drawings.
Installation of this product requires a person familiar with the
construction and operation of the luminaire’s electrical system
and the hazard involved. If not qualied, do not attempt
installation. Contact a qualied electrician.
To prevent wiring damage or abrasion, do not expose wiring
to edges of sheet metal or other sharp objects.
Do not make or alter any open holes in an enclosure of wiring
or electrical components during kit installation.
Installation requires input rating of the retrot kit to not
exceed the input rating of the luminaire.
RISQUES D’INCENDIE OU DE DÉCHARGES ÉLECTRIQUES
Couper l’alimentation avant l’inspection, l’installation ou d’effectuer
de la maintenance
N’ installer cette trousse que sur des luminaires qui ont les caractéristiques
de construction et les dimensions telles que montrées sure les
photographies et dessins présentés.
Risque d’incendie ou d’électrocution. L’installation du product nécessite
la connaissance de la construction et le fonctionement de l’installation
électrique du luminaire. Contactez un(e) électricien(ne) qualié(e).
Pour prévenir les dommages ou l’abrasion de ls électriques, ne pas exposer
les ls aux arêtes de pièce de tôlerie ou n’importe quels autres objets
tranchant.
Ne pas percer ou altérer les trous d’un boitier contenant l ou composant
électrique durant l’installation.
L’installation nécessite que la valeur nominale d’entrée du kit ne dépasse
pas la valeur nominale d’entrée du luminaire originale.
CAUTION / ATTENTION
Fixture suitable for wet locations, covered ceiling
mount only.
Fixture may fall down if not installed properly,
follow installation instructions.
Wear appropriate Personal Protective Equipment (PPE)
during installation and maintenance.
Use only UL certied wires, wire connectors,
minimum 18AWG, minimum rated 90°C.
Les luminaires sont adaptés aux endroits humides et ne s’appliquent
qu’aux plafonds couverts.
Le luminaire peut tomber s’il nest pas installé correctement, suivre les
instructions d’installation.
Porter les Équipement de Protection Individuelle (EPI) adaptés lors de
l’installation et de l’entretien.
N’utilisez que des ls et connecteurs approuvés par UL. Calibre minimum
18AWG (0.75mm2) et température minimale de 90°C.
Prepare Electrical Wiring FCC STATEMENT
Electrical Requirements
The LED luminaire must be connected to
the mains supply according to its ratings
on the product label.
Class 1 wiring should be in accordance
with NEC.
Grounding Instructions
The grounding and bonding of the overall
system shall be done in accordance to local
electric code of the country where the luminire
is installed.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2)This device must
accept any interference received, including interference that may cause undesired operation.
CAN ICES-005(A)/ NMB-005(A)
Note: This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at their own expense.
Lumination® (LRXB - Series) Installation Guide
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved.
Information and specifications subject to change without notice.
All values are design or typical values when measured under
laboratory conditions.
Page 2 of 7
(Rev 4/19/23)
IND668-Lumination-LRXB-Series-LED-Luminaire-Retrofit-and-New-Construction-Install-Guide_R01
Contents
1. Direct-Mount installation ..............................................................................................................................................................................................2
2. Retrot Installation ..........................................................................................................................................................................................................5
3. Frame-kit/pan installation .............................................................................................................................................................................................6
1. Direct-Mount Installation
Luminaire Installation
Before installation, check the xture size and the diameter of ceiling
opening according to below Tab1.
Provided Components
The components have been properly packed to avoid damage during
transit. Inspect the components to conrm there is no
physical damage. Do not install damaged components.
Components List
• LRXB Fixture Kit
• Installation Instructions
Tab 1
Fixture
Size
Fixture
Type
Opening Size
in Ceiling (inch)
Fixture
weight (kg)
Suitable Ceiling
Max Thickness
4 Round 4.5~5.0 0.475 5/8″
6 Round 6.0~6.7 0.525 3/4
8Round 7.8~8.8 0.615 1
10 Round 10.2~11.2 1.260 1
12 Round 12.2~13.2 1.410 1
4 Square 4.5~5.0 0.600 5/8
6 Square 6.0~6.8 0.700 3/4
8 Square 8.0~9.0 0.870 1
2
1
Round Square
NOTE: For 10’’ and 12’’ xtures, a suitable UL Listed frame-kit is
recommended to be used with the xture for installation safety.
Cut an access opening in the ceiling with the diameter listed in Tab 1,
and install the xture to the ceiling per the codes. Make sure the
ceiling can withstand the weight of the xture and the thickness of
ceiling be less than the list in Tab1.
Ensure the center of existing J-Box cover is visible through the access
opening, and the connections to the branch circuit supply are visible
through the access opening.
Ensure that the power to the unit is turned off. Use proper lockout/
tagout procedures. See g A.
A
B
Fig A
Fig B
J-Box cover
(not provided)
Access opening
cut by customer
Fixture
Lumination® (LRXB - Series) Installation Guide
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved.
Information and specifications subject to change without notice.
All values are design or typical values when measured under
laboratory conditions.
Page 3 of 7
(Rev 4/19/23)
IND668-Lumination-LRXB-Series-LED-Luminaire-Retrofit-and-New-Construction-Install-Guide_R01
Connect the black, white, yellow/green leads from the conduit to the power-supply with UL listed wire
connectors according to the wiring diagram C2. Be sure all connection are made inside the existing J-Box.
Optional Dimmer: When connecting a dimming Controller, connect the violet (dimming+) and pink (dimming-)
wires to the violet and pink wires of the xture.
Note: Cap all unused dimming leads with wire nuts.
Note: Phase cut dimmers must be wired to the power feed “hot” line (L). For 0-10V and phase cut dimming
compatibility, please visit: www.led.com/dimming
Select Lumen (8” luminaires with 3000lm are not
lumen selectable):
C
C
Fig D1 Fig D2
Fig D2
LRX
Fixture
To 0–10V
Dimmer
LED
Driver
L
N
Ground
Violet
White
0–10V−
0–10V+
Green / Yellow
1000/650lm luminaires 1800/1000/650lm luminaires
Lumen Switch Lumen Switch
NOTE: For 1800/1000/650lm luminaires, the default
lumen is 1000lm. Push the switch up to activate 650lm.
Push the switch down to activate 1800lm. See g D2.
Fig C1
Conduit from
xture
Power Supply (not provided)
UL listed connectors
(not provided)
J-Box
(not provided)
Ceiling opening
NOTE: For 1000/650lm luminaires, the default lumen
is 1000lm. Push the switch down to activate 650lm.
See g D1.
NOTE: For 4000/5000/6000lm luminaires, the de-
fault lumen is 6000lm. Push the switch left to activate
4000lm and 5000lm respectively.
See g D3.
Lumination® (LRXB - Series) Installation Guide
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved.
Information and specifications subject to change without notice.
All values are design or typical values when measured under
laboratory conditions.
Page 4 of 7
(Rev 4/19/23)
IND668-Lumination-LRXB-Series-LED-Luminaire-Retrofit-and-New-Construction-Install-Guide_R01
Select CCT
C
C
Fig E1
Fig E3 Fig E4
Fig E5
Fig F
Fig E2
2700K/3500K/3000K luminaires 3500K/4000K/5000k luminaires
CCT Switch
Switch Cover
Switch Cover
CCT Switch plug
CCT Switch
Lumen Switch
CCT Switch
NOTE: For 3500K/4000K/5000K luminaires, the
default CCT is 4000K. Push the switch up to activate
3500K, push the switch down to activate 5000K.
See g E2 or E4.
NOTE: For 10in and 12in xtures, the CCT switch is
located on the housing sealed by a plug, and the
cover of the lumen switch can be used as a tool to select
lumen and CCT. See g E4.
NOTE: The cover of the lumen/CCT switches can
be used as a tool to select lumen and CCT.
See g E3.Place the switch cover back after lumen
and CCT setting.
Load springs into upright position by twisting the
springs upward and carefully insert the xture into
ceiling opening. The springs will rotate back into
position and hold the xture tight to the ceiling.
ONLY FOR 10IN AND 12IN FIXTURES: The CCT switch
plug must be placed back after CCT selection to avoid
light leakage and dust/bug ingress. See g E5.
ATTACH THE SAFETY TETHER TO THE
RECOMMENDED FRAME-KIT FOR REDUNDANT
INSTALLATION SAFETY.
NOTE: For 2700K/3000K/3500K luminaires, the
default CCT is 3500K. Push the switch up to activate
2700K, push the switch down to activate 3000K. See
g E1 or E4.
CAUTION/ATTENTION
RISK OF PERSONAL INJURY - Operators shall ensure no
appendages are in the path of the torsion springs as they are
a pinch hazard when released. The springs will release when
the arm is exed downward. Be cautious that no body part is
in the path of the spring when released.
RISQUE DE BLESSURE CORPORELLE - Les techniciens
veilleront à ce qu’aucun appendice ne se trouve sur le
chemin des ressorts de torsion, car ils présentent un rique
de pincement lorsqu’ils sont libérés. Les ressorts seront libérés
au moment de échir le bras vers le bas. Faites attention à ce
qu’aucune partie du corps ne se trouve sur le chemin du
ressort à sa libération.
Lumination® (LRXB - Series) Installation Guide
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved.
Information and specifications subject to change without notice.
All values are design or typical values when measured under
laboratory conditions.
Page 5 of 7
(Rev 4/19/23)
IND668-Lumination-LRXB-Series-LED-Luminaire-Retrofit-and-New-Construction-Install-Guide_R01
2. Retrot Installation
Luminaire Installation
Before installation, verify that the existing junction box
and frame-kit are metal construction, designed similarly
to g 2.
Note: Installers should examine all parts that are not
intended to be replaced by the retrot kit for damage
and replace any damaged parts prior to installation of
the retrot kit.
Fixture
Size
Fixture
Type
Existing Bracket
Hole Size (inch)
4 Round 4.5~5.0
6 Round 6.0~6.7
8Round 7.8~8.8
10 Round 10.2~11.2
12 Round 12.2~13.2
4 Square 4.5~5.0
6 Square 6.0~6.8
8 Square 8.0~9.0
Fig 2
2
Fig 2A
Fig 2B
Fig 2C
A
B
C
Ensure that the power to the unit be turned off.
Use proper lockout/tagout procedures.
Remove existing lamps, xture and ballast.
Leave wiring in junction box. Verify that the
AC supply line is provided with a ground
wire connected to the luminaire. See g 2B.
Connect conduit end with input leads to existing
J-Box and make the proper connections according
to diagram C1/C2.
Make all electrical connections sing UL Listed
wire connectors.
Securely close J-Box after wiring. See g 2C.
Lumination® (LRXB - Series) Installation Guide
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved.
Information and specifications subject to change without notice.
All values are design or typical values when measured under
laboratory conditions.
Page 6 of 7
(Rev 4/19/23)
IND668-Lumination-LRXB-Series-LED-Luminaire-Retrofit-and-New-Construction-Install-Guide_R01
About selecting CCT or lumen level, refer to
step D and E on page 3 and 4.
Load springs into upright position by twisting the
springs upward and carefully insert the xture to
ceiling opening.
The springs will rotate back into position and hold
the xture tight to the ceiling .
Only for 10 in and 12 in:
ATTACH THE SAFETY TETHER TO THE FRAME KIT
FOR REDUNDANT INSTALLATION SAFETY.
See g 2E.
D
D
E
WIRING DIAGRAM C1
0–10 VOLT DIMMING
LRX
Fixture
To 0–10V
Dimmer
LED
Driver
L
N
Ground
Black
Pink
Violet
White
0–10V−
0–10V+
Green / Yellow
Optional Dimmer: Optional Dimmer: When
connecting a dimming controller, low-voltage dimming
wires must route through a separate knockout. Connect
the violet (dimming+) and pink (dimming-) wires to the
violet and pink wires of the xture.
Note: Cap all unused dimming leads with wire nuts
Note: Phase cut dimmers must be wired to the
power feed “hot” line (L). For 0-10V and phase cut
dimming compatibility, please visit:
www.led.com/dimming
CAUTION/ATTENTION
RISK OF PERSONAL INJURY - Operators shall ensure no
appendages are in the path of the torsion springs as they are
a pinch hazard when released. The springs will release when
the arm is exed downward. Be cautious that no body part is in
the path of the spring when released.
RISQUE DE BLESSURE CORPORELLE - Les techniciens
veilleront à ce qu’aucun appendice ne se trouve sur le
chemin des ressorts de torsion, car ils présentent un rique
de pincement lorsqu’ils sont libérés. Les ressorts seront libérés
au moment de échir le bras vers le bas. Faites attention à ce
qu’aucune partie du corps ne se trouve sur le chemin du
ressort à sa libération.
Fig 2E
Fig 2F
3. New Construction Installation
Provided Components
The components have been properly packed to avoid damage during transit. Inspect the components to conrm
there is no physical damage. Do not install damaged components. See Fig 3A and Tab 3.
1
Lumination® (LRXB - Series) Installation Guide
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved.
Information and specifications subject to change without notice.
All values are design or typical values when measured under
laboratory conditions.
Page 7 of 7
(Rev 4/19/23)
IND668-Lumination-LRXB-Series-LED-Luminaire-Retrofit-and-New-Construction-Install-Guide_R01
1
2 3 4 5
Tab 3
Provided Item Qty.
1 Frame (4-inch, 6-inch, 8-inch, 10-inch or 12-inch) 1
2 Mounting Brackets 2
3 L-Bracket 2
5 Wing Nut 3
Fixture
Diameter
Hole
Diameter
RX6 5.9–6.5 in.
RX8 7.6–8.2 in.
L-brackets
Mounting brackets
Place side L-brackets on existing
frame screws and tighten with
screwdriver on both sides of the
frame. Then attach mounting
brackets to both L-brackets with wing
nuts (provided).
Cut an appropriate hole on the
ceiling tile according to Tab 4.
Ensure the ceiling hole diameter
match the frame opening diameter.
Fixture
Diameter
Hole
Diameter
RX6 5.9–6.5 in.
RX8 7.6–8.2 in.
L-brackets
Mounting brackets
Slide hanger bars
(order separately)
through adjustable
mounting brackets.
Mounting brackets could also be
xed on the short side of frame.
Bars Conduit
A B
Adjust height and
tighten wing nut
Option A: Mount xture by attaching
hanger bars to T-Grid ceiling
(BH3 SKU 94890).
Option B: Mount xture with ½” EMT
conduit. (Not Supplied)
Bars Conduit
A B
Adjust height and
tighten wing nut
Adjust xture height to be ush with
ceiling and tighten both mounting
bracket wing nuts.
Refer to steps C-F of the retrot installation above to nish the installation.
A B C
D E F
G
Frame Installation
1
Tab 4
Fixture
Size
Fixture
Type
Suitable
Frame
Suitable Ceiling
Max Thickness
4 Round FRAME4R 5.0~5.5
6 Round FRAME6R 6.6~7.1
8Round FRAM8R 8.2~8.7
10 Round FRAME10R 10.6~11.2
12 Round FRAME12R 12.5~13.3
4 Square FRAME4S 5.1~5.6
6 Square FRAM6S 6.9~7.4
8 Square FRAME8S 8.5~9.4
Fig 3A
Access Opening
J-Box Cover