PREPARATION
1. Shut off the power at the circuit breaker and remove existing fixture,
including the crossbar.
2. Carefully unpack your new fixture and lay out all the parts on a clear area.
Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (B) and back plate from the fixture.
4. Drill holes in the wall aligned with the key hole located in the mounting
back plate, insert the plastic anchors(C).
5. Secure the mounting back plate to the junction box using standard
junction box screws that comes with the junction box. Fasten it to the
wall using wood screw (D).
Note: the side of the mounting plate marked “GND” must face out.
6. Properly secure the safety cord to the bracket on mounting back plate to
temporary hang the fixture in place.
7. Adjust the fixture wire length by pushing the cable gripper onthe canopy
and pulling the wire as desired.
a. Retract the wires close to the desired length within thecanopy
before securing the fixture in place.
NOTE: Using the cable gripper to adjust more than 18” of wire length is
not recommended.
WARNING: Shortening the cables without professional help or electronic
background is not advisable. Any modifications to the fixture will result
in voiding the warranty of the product.
CONNECTING THE WIRES (Fig. 2)
8. Connect the driver’s input wires to junction box wires as shown in Fig. 2,
making sure that all wire connectors (A) are secured. If your outlet box has
a green or bare copper ground wire, connect the xture’s ground wire to it.
Otherwise, connect the fixture’s ground wire directly to the back plate
using the green screw provided. After wires are connected, tuck them
carefully inside the junction box.
COMPLETING THE INSTALLATION
9. Hold the canopy in both hands and put it on the mounting ring as shown
in the Fig. 1, then rotate in the direction of the arrow until it can't move.
Secure it with mounting screw (B).
NOTE: DIMMING WIRING INFORMATION (Fig. 3)
10. This fixture features electronic low voltage (ELV) or 0-10V dimming capabilities. See notes below for speci c dimming wires information..
11. To utilize ELV dimming: use wires black (hot), white (neutral) and green ground wire (ground). .
12. To utilize 0-10V dimming: use wire purple (dim+), Pink or gray (dim-), black (hot), white (neutral) and green ground wire (ground).
2
INSTALLATION INSTRUCTIONS
750 - Indoor Pendant
PD-75027
FIG.1
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Nov. 2019
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Ø61
4"
Ø31
2"
Ø23
4"
Ø81
8"
Purple - Dim+
Black - Output -
Red - Output +
White - Neutral
Black - Hot
Purple - Dim+
Pink or gray-Dim-
Black - Output -
Red - Output +
Outer Ring
Inner Ring
Outer bare cord
Inner cord
Inner cord
Outer bare cord
LD-1200MA50U-DI-IS
LD-350MA14U-DIM-IS
Push up
Cable-gripper
Mounting screw
B
Junction box
Driver(2pcs)
Junction box screw
Plastic anchor
Safety cord
A
Wire connector
Mounting backplate
Ground wire
Wood screw
C
D
Driver input wire
Cord
Fixture
FIG. 2 Wiring
Mounting Backplate DimensionFIG. 3 Driver Wiring
Pink or gray-Dim-