Factory Default Reset (FDR)
Locate default code sticker on lock before attempting
factory default reset (FDR) procedure. Deleted codes
CANNOT be recovered! This will erase all stored information!
Please use this procedure only when the network primary
controller is missing or otherwise inoperable.
Read the full FDR procedure before beginning.
Troubleshooting
Problem Sound Lights Solution
After entering a user code to unlock the lock, the yellow
light is ashing and there is a delay before it unlocks.
4 beeps 4 yellow
ashes
The battery is low and should
be replaced.
10 red ashing lights when outside lock button is
pressed.
---- 10 red
ashes
Battery is critical and must be
replaced.
Valid user code will not unlock. 2 beeps 2 green and
red ashes
Vacation Mode is enabled.
Disable Vacation Mode.
---- ---- Must press after
entering user code.
Cannot add user code. 3 beeps 3 red
ashes
Exceeded the user code limit.
Deadbolt tries to extend twice but doesn’t extend. 2 beeps 2 red
ashes
Deadbolt jammed, Adjust bolt/
frame alignment.
DEADBOLT MODELS (JBE105, JBE109)
LYou must re-enter a default access code followed by
to set up the lock after restoring to factory default!
1 Determine which deadbolt you have.
Remove battery cover. If there is a small button under the
batteries, you have a JBE109 Connected Deadbolt. Follow
labeled steps below. If there is no small button under the
batteries, you have a JBE105 Deadbolt. Follow labeled steps
below.
JBE109 Connected Deadbolt
AA
AA
AA
AA
1. Press and hold the enrollment button.
The led will light solid amber.
2. After about 8 seconds of holding the
button, the amber light will turn o.
Release the button. Successful FDR is
indicated by 3 long green blinks and 3
long beeps.
3. You must enter a valid user code.
Lock will enter auto-handing routine,
locking and unlocking several times.
Auto-handing is complete when lock
movement stops.
JBE105 Deadbolt
Press and hold SET button while inserting the
battery back. Hold the set button until long beep
over.
Appuyez et maintenez le bouton SET tout en
insérant la pile enlevée. Maintenez le bouton SET
Remove one battery
Retirez une pile
AA
AA
AA
AA
AA
AA
AA
AA
AA
1. Remove one battery.
2. Press
Press and hold SET button while inserting the
battery back. Hold the set button until long beep
over.
Appuyez et maintenez le bouton SET tout en
insérant la pile enlevée. Maintenez le bouton SET
Remove one battery
Retirez une pile
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA
3. Replace the battery then wait until power
up is complete, indicated by 1 long green
blink and 1 long beep. You must complete
the next step within 10 seconds.
4. Press and hold for 3 seconds.
Successful FDR is indicated by 3 long
green blinks and 3 long beeps.
5. Enter default access code followed by lock button to set
up lock!
LEVER MODELS (JFE105, JFE109)
1 Determine which lever you have.
Remove battery cover. If there is a small button under the
batteries, you have a JFE109 Connected Lever. Follow
labeled steps below. If there is no small button under the
batteries, you have a JFE105 Lever. Follow labeled steps
below.
JFE109 Connected Lever
1. Press and hold the enrollment
button. The led will light solid amber.
2. After about 8 seconds of holding the
button, the amber light will turn o.
Release the button. Successful FDR
is indicated by 3 long green blinks
and 3 long beeps.
JFE105 Lever
AA
AA
AA
AA
1. Remove one battery.
2. Press
AA
AA
AA
AA
3. Replace the battery then wait until
power up is complete, indicated by
1 long green blink and 1 long beep.
You must complete the next step
within 10 seconds.
4. Press and hold for
3 seconds. Successful FDR is
indicated by 3 long green blinks and
3 long beeps.
Z-Wave™ Functions
ONLY FOR
JBE109 Connected Deadbolt
JFE109 Connected Lever
About Z-Wave™
This lock is a Security Enabled Z-Wave Product.
•This product can be operated in any Z-Wave network with
other Z-Wave certied devices from other manufacturers.
All mains operated nodes within the network will act as
repeaters regardless of vendor to increase reliability of the
network.
•S2 security enabled controller is required to operate the
product. The lock will have limited functionality if included
with a non-secure controller.
•Refer to your home automation system’s documentation
for more information.
Add or Remove lock from Z-Wave network
1. Place your Z-Wave Controller into the “Add” (Inclusion
Mode) or “Remove” (Exclusion Mode). Refer to the
respective documentation for your home automation
system for details.
2. Remove the battery cover.
3. Press and hold enrollment button under battery cover for
0.5 to 3 seconds as shown. Solid amber LED will be ON.
AA
AA
AA
AA
4. Release the enrollment button. An LED will ash amber
indicating the “Add” or “Remove” process is in progress.
5. Success is indicated by a green LED blink and a beep.
LIf a red LED turns on, try repeating steps 1-3.
Z-Wave Plus™
For enrollment in some Z-Wave Plus networks, an additional
5 digit code may be required to be entered into the home
automation system or panel during Step 4. Enter the 5
digit code shown on the label located on lock or on the
cover of the included installation instructions. Refer to your
home automation system’s documentation or app for more
information.
JBE109 Deadbolt and JFE109 Lever can be added into a
Z-Wave network by scanning the Z-Wave QR Code at the
start of this user guide with a controller providing
SmartStart inclusion.
No further action is required and the SmartStart product will
be added automatically within 10 minutes of being switched