BEST Range Hoods CC34IQSB Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation
Model CC34IQSB
ENGLISH.....................................2
FRANÇAIS.................................17
ESPAÑOL..................................33
In USA - BEST Hartford, Wisconsin
In CANADA - BEST Drummondville, QC, Canada
REGISTER YOUR PRODUCT ONLINE AT : www.BestRangeHoods.com/register
For additional Information visit www.BestRangeHoods.com
- 2 -
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact
the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel
to prevent power from being switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with
all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s
guidelines and safety standards such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden
utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any separate solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. Type Non-IC Installation: Thermal insulation shall not cover top of range hood housing and must
be spaced 3-inches (76mm) from all sides. (Fig. 1)
!
INTENDED FOR DOMESTIC COOKING ONLY
!
3-INCH MINIMUM.
NO INSULATION
WITHIN THIS SHADED
AREA OF COMPONENTS.
FIG. 1
- 3 -
!
CAUTION
1. For indoor use only.
2. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust
air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
3. Take care when using cleaning agents or detergents.
4. Avoid using food products that produce flames under the Range Hood.
5. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and
vapors.
6. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.
7. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes
overheated. The motor will restart when it cools down. If the motor continues to shut off and
restart, have the hood serviced.
8. For best capture of cooking impurities, the bottom of the hood should be a minimum of 48”
and a maximum of 72” above the cooking surface. See “Install Mounting Bracket” section for
mounting restrictions.
9. Two installers are recommended because of the large size and weight of this hood.
10. The light source is designed for this specific application and can overheat if serviced by untrained
personnel. If any servicing is required, the product should be returned to an authorized service
facility for examination or repair.
11. Please read specification label on product for further information and requirements.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low or medium settings.
B. Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette,
Cherries Jubilee, Peppercorn Beef Flambe’).
C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
D. Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner.
BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND
CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
- 4 -
OPERATION
Controls (Fig. 2)
The hood is operated using the (5) push-buttons located on the hood and the remote control.
LED colors are displayed on hood control only.
FIG. 2
(P1) Delay- Off Switch
• Yourhoodincludesa10minuteblowerdelayoffswitch.Pressthisswitchoncetoactivatethe
timer and the LED Ring (L1) flashes blue. The blower will continue to operate for 10minutes.
After 10 minutes, the blower turns off automatically.
To cancelthe10-minutedelay,pressthedelayswitchonceagain.
(P2) Filter Alarm Switch
• After30hoursofbloweroperation,thefilteralarmisactivatedandtheLEDring(L1)turnsred/
flashes. It indicates that the grease filters need to be cleaned.
• Aftercleaningthegreasefilters,resetthehourcounterbypressingtheFilterAlarm/TimerReset
button (P2) during display of the alarm.
(P3) Blower Speed Decrease and Off Switch
• Press to decrease blower speed, high to low.The LED ring (L1) flashesblue at a speed
proportionate to the blower setting (i.e.: four flashes is high speed, one flash is low speed, etc.)
• Continuepressingthisswitchtoturnthebloweroff.
(P4) Blower Speed Increase and On Switch
• Pressthisswitchtoturntheblowerontolowspeed.
• Pressagaintoincreaseblowerspeed,lowtohigh.TheLEDring(L1)flashesblueataspeed
proportionate to the blower setting (i.e.: four flashes is high speed, one flash is low speed, etc.)
(P5) Light Switch
Turns the lights on and off.
P1: Activate/deactivate delay-off (10 minute)
P2: Filter change indication timer reset
P3: Decreases fan motor speed until turned off (4>3>2>1>OFF)
P4: Turns fan motor on and increased speed (ON>1>2>3>4)
P5: Turns lights on/off
L1: LED Indicator Ring Signalling crown:
- Hood in standby: lights up green. 30 seconds after
the last key has been pressed the crown turns off
- Motor on: L1 lights up blue
The
frequency is proportional to the speed setting.
- 10’ TIMER function : L1 lights up and flashes blue.
- Filter alarm active: L1 lights up red
L1
LED
RING
+
-
ƒ
¤
(P1)
(P2)
(P3)
(P4)
(P5)
Auto Shut-Off Feature
If the blower and/or the lights are on continuously for 10 hours without any user interaction with
the controls, the hood will automatically shut off. Press any control button to re-activate the hood.
- 5 -
HOOD
CONTROL
REMOTE CONTROL
The remote control is linked to the hood at the factory.
If, for some reason, the link is lost - follow the directions below:
To Link Remote Control to Hood
1. Turn off hood motor and hood lights.
2. Press
on the remote control for at least 3 seconds. The indicator light will light up. (Fig. 3)
3. While holding
on the remote control - press ƒ (P2) on the hood control. (Fig. 4) The LED
ring will light up GREEN for approximately 10 seconds to confim that the linking process was
successful.
P1: Activate/deactivate delay-off (10 minute)
P2: Filter change indication timer reset
P3: Decreases fan motor speed until turned off (4>3>2>1>OFF)
P4: Turns fan motor on and increased speed (ON>1>2>3>4)
P5: Turns lights on/off
L1: LED Indicator Ring Signalling crown:
- Hood in standby: lights up green. 30 seconds after
the last key has been pressed the crown turns off
- Motor on: L1 lights up blue
The
frequency is proportional to the speed setting.
- 10’ TIMER function : L1 lights up and flashes blue.
- Filter alarm active: L1 lights up red
L1
LED
RING
+
-
ƒ
¤
(P1)
(P2)
(P3)
(P4)
(P5)
INDICATOR
LIGHT
FIG. 4
FIG. 3
P1
P2
P3
P4
P5
- 23A +
P1
P2
P4
P3
HOOD
P1: 5' TIMER function activation/deactivation.
hood sensor: AUTOMATIC function activation/
deactivation.
P2: Motor off/motor speed decrease.
P3: Motor on/motor speed increase.
P4: Lights on/off.
As soon as the button is
pressed, the circular crown
lights up for 1".
Battery disposal
When the batteries need to be replaced, dispose of them only and exclusively in the numerous readily available
special waste bins, especially in shops selling electronic consumer goods. Observance of the regulations on
differentiated waste collection, in particular, proper disposal of used batteries, contributes to preventing possible
negative effects on the environment and health.
LINKING procedure
- To unambiguously associate the radio control with
the hood, you can activate a LINKING procedure.
Once the procedure has terminated, the radio
control functions only and exclusively with the
associated product.
- This procedure is useful if there are two or more
products that can be controlled by means of radio
control, for example, in apartments with adjacent
kitchens, showrooms, fairs, etc.
1 - Turn off the hood motor and the lights
2 - Press P1 for 3": the circular crown will light up
3 - Confirm the link to the hood within 3" by pressing
the button indicated on the next page.
Confirm P2
CAUTION RISK OF EXPLOSION IF BATTERY IS
REPLACED BY AN INCORRECT TYPE. DISPOSE
OF USED BATTE TO THE INSTRUCTION.
Remote Control Functions (Fig.3)
Delay - Off
Blower Speed Decrease and Off
Blower Speed Increase and On
Light
P1
P2
P3
P4
P5
- 23A +
P1
P2
P4
P3
HOOD
P1: 5' TIMER function activation/deactivation.
hood sensor: AUTOMATIC function activation/
deactivation.
P2: Motor off/motor speed decrease.
P3: Motor on/motor speed increase.
P4: Lights on/off.
As soon as the button is
pressed, the circular crown
lights up for 1".
Battery disposal
When the batteries need to be replaced, dispose of them only and exclusively in the numerous readily available
special waste bins, especially in shops selling electronic consumer goods. Observance of the regulations on
differentiated waste collection, in particular, proper disposal of used batteries, contributes to preventing possible
negative effects on the environment and health.
LINKING procedure
- To unambiguously associate the radio control with
the hood, you can activate a LINKING procedure.
Once the procedure has terminated, the radio
control functions only and exclusively with the
associated product.
- This procedure is useful if there are two or more
products that can be controlled by means of radio
control, for example, in apartments with adjacent
kitchens, showrooms, fairs, etc.
1 - Turn off the hood motor and the lights
2 - Press P1
for 3": the circular crown will light up
3 - Confirm the link to the hood within 3" by pressing
the button indicated on the next page.
Confirm P2
CAUTION RISK OF EXPLOSION IF BATTERY IS
REPLACED BY AN INCORRECT TYPE. DISPOSE
OF USED BATTE TO THE INSTRUCTION.
Note: Filter reset is not possible with the
remote.
See “Controls” section on previous page for
more information on each function.
- 6 -
CLEANING AND MAINTENANCE
Proper maintenance of the Range Hood will assure proper performance of the unit.
Motor
The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or
unusual noise, replace the motor with the exact service motor. The impeller should also be replaced.
Grease Filters
The grease filters should be cleaned frequently. Use a warm detergent solution. Grease filters are
dishwasher safe.
Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may
occur if using phosphate detergents, or as a result of local water conditions - but this will not affect filter
performance. This discoloration is not covered by the warranty.
See “INSTALL FILTERS” section for removal and installation instructions.
Stainless Steel Cleaning
DO:
• Regularlywashwithcleanclothorragsoaked
with warm water and mild soap or liquid dish
detergent.
• Alwayscleaninthedirectionoforiginalpolish
lines.
• Alwaysrinsewellwithclearwater(2or3times)
after cleaning. Wipe dry completely.
Yo u may also use a specialized household
stainless steel cleaner.
DON’T:
•
Use any steel or stainless steel wool or any
other scrapers to remove stubborn dirt.
• Useanyharshorabrasivecleansers.
• Allowdirttoaccumulate.
• Let plaster dust or any other construction
residues reach the hood. During construction/
renovation, cover the range hood to make sure
no dust sticks to the stainless steel surface.
Avoid: When choosing a detergent
• Anycleanersthatcontainbleachwillattackstainlesssteel
• Anyproductscontaining:chloride,fluoride,iodide,bromidewilldeterioratesurfacesrapidly.
• Anycombustibleproductsusedforcleaningsuchasacetone,alcohol,ether,benzol,etc.,arehighly
explosive and should never be used close to a range.
- 7 -
PREPARE THE HOOD
Unpack hood and check contents.
You should receive:
1 - Range Hood Body
1 - Remote Control
6 - Grease Filters
2 - Screws, 4 x 9.5 mm
6 - Lag Bolts, 6 x 70 mm
6 - Washers
6 LAG BOLTS
(6 x 70 mm)
FIG. 5
REMOTE
CONTROL
RANGE HOOD
BODY with DAMPER
6 GREASE
FILTERS
6 WASHERS
2 SCREWS
(4 x 9.5 mm)
- 8 -
INSTALL THE DUCTWORK
FIG. 6
ROOF CAP
48" TO 72" ABOVE
COOKING SURFACE
HOOD
8" ROUND
DUCT
8" ROUND
TO 3¼” X 14”
REDUCER
3¼” X 14”
UNDER
EAVE
VENT
8" ROUND
DUCT
WARNING: To reduce the
risk of fire, use only metal duc-
twork.
1. Decide where the ductwork will
run between the hood and the
outside. Fig. 6.
2. A straight, short duct run will
allow the hood to perform most
efficiently.
3. Long duct runs, elbows, and
transitions will reduce the per-
formance of the hood. Use as
few of them as possible. Larger
ducting may be required for
best performance with longer
duct runs.
4. Install a roof cap, wall cap, or under-eave vent. Connect round metal ductwork to cap/vent
and work back towards hood location. Use duct tape to seal the joints between ductwork
sections.
5. The blower can be rotated according to the air outlet location. See Fig. 7 for air outlet
dimensions.
8¾”
13¾”
8¾”
21
11
/16
FIG. 7
- OR -
LOCATION OF HOOD OUTLET
- 9 -
PREPARE THE HOOD
SUPPORT
1. Construct a wood framing system
as shown in Fig. 9.
2. The structure must be capable of
supporting its own weight, plus the weight
of the hood (64 pounds).
FIG. 9
2 x 4
FRAMING
37-1/4”
42-1/2”
14
26-3/4”
2-5/8”
1/8” PILOT
HOLE (6)
11 1111 11
1/8” PILOT
HOLE (6)
PREPARE THE CEILING
OPENING
The hood should always be centered over the
cooktop. Make sure there is adequate space
in the ceiling structure to install the hood and
ductwork. The hood should be mounted 48”
to 72” above the cook top for best removal of
cooking impurities. Fig 6.
Use joist size lumber to frame in around the
range hood opening. The ceiling structure
must be able to support the weight of the
hood (64 pounds). Fig 8.
FIG. 8
DOUBLE HEADERS
42
1
/
2
26¾”
- 10 -
ATTACH CONTROL BOX
1. Remove control box from side of blower
box. Fig. 10.
2. Insert control box into opening. Fig. 11.
3. Attach control box with (2) 4 x 9.5 mm
screws provided. Fig. 12.
FIG. 10
FIG. 11
FIG. 12
CONTROL BOX
TAPED TO
BLOWER HOUSING
CONTROL
BOX
OPENING
IN HOOD
ATTACH SCREWS
ON FILTER SIDE
(2) 4mm X 9.5mm
SCREWS
- 11 -
INSTALL THE HOOD
CAUTION: At least two installers are
recommended because of the large size
and weight of this range hood.
1. Hood is shipped in the horizontal duct
discharge position and is ready to be
installed.
2. To change direction of the duct without
using elbows. Fig. 13:
• Remove(2)screwsfrominsideofblower
box.
• Remove(4)screwsfromsidesofblower
box.
• Removeblower,turnblower90degrees,
reinstall (4) screws.
3. Lift range hood into the ceiling opening.
4. Secure each support frame to the wooden
hood support frame using (6) 6 x 70 mm
lag bolts and washers provided. Fig. 14.
5. Adjust height of the telescoping support
frame to ensure a tight fit between the
hood and finished ceiling.
6. At the blower discharge collar, connect
ductwork that exhausts air to the outside
discharge.
7. Duct tape all joints to ensure an air tight
seal.
FIG. 13
SCREWS (4)
FIG. 14
2 X 4 WOOD
FRAME
(6) WASHERS
& LAG BOLTS
CONNECT THE WIRING
WARNING: All electrical wiring
should be done by a qualified person (s)
in accordance with all applicable codes
and standards. This range hood must be
properly grounded.
Do not turn blower on at the service panel
until all wires have been connected.
1. Run 2-wire plus ground, 120 VAC electrical
power cable to the ¾” knockout located on
the back of the hood. Fig. 15.
2. Remove ¾” electrical knockout from the
back of the hood.
FIG. 15
2-WIRE PLUS
GROUND
120 VAC
LINE IN
KNOCKOUT
- 12 -
CONNECT WHITE-TO-WHITE,
BLACK-TO-BLACK, GREEN-TO-GROUND
FIG. 16
FIG. 17
120 VAC
LINE IN
BOX MARKED
“120VAC INPUT”
3. From the room interior, pull down both
closure panels. Fig. 16.
4. Remove (4) screws from the electrical
compartment access panel. Slide the
panel sideways to expose the electrical
wiring box.
5. From the electrical box marked “120 VAC
Inlet”, remove (2) screws that secure the
cover to the metal wiring box. Fig. 17.
6. Pull 120VAC electrical power cable into
the box and secure with an appropriate
cable clamp.
7. Make electrical connections inside the
box. Connect white-to-white, black-to-
black and green-to-ground.
8. Replace the wiring box cover and the
screws. Make sure wires are not pinched
between the cover and box.
9. Replace the electrical compartments ac-
cess panel and (4) screws.
MAKE-UP AIR DAMPER
The hood is compatible with Broan Make-Up Air Damper Model MD6T, Model MD8T or Model
MD10T (optional). Purchase separately.
Make the connection to the Make-Up Air Damper with low voltage wiring, as shown. See
Make-Up Air Damper instructions for additional information. (Fig. 18)
MAKE-UP AIR DAMPER
HOOD
24V
TRANSFORMER
(INCLUDED)
GRD
WIRE BOX
FOR LOW
VOLTAGE
CONNECTION
MAKE UP DAMPER CONNECTION
(switched low voltage)
20 GAUGE BELL WIRE FOR LOW
VOLTAGE CONNECTION ON
TOP OF HOOD
120 VAC
60 HZ
FIG. 18
- 13 -
INSTALL THE FILTERS
1. Pull down both closure panels as shown.
Fig. 19 and Fig. 20.
2. To install the grease filters, align rear filter
tabs with slots in the hood. Push latch tab
in, push filter into position and release.
Make sure filter is securely engaged after
installation.
3. To remove the filters for cleaning, push
latch tab in to disengage filter from hood.
Tilt the filter downward and remove.
FIG. 19
FIG. 20
CALIBRATE IQ BLOWER
SYSTEM
TM
INTERNAL BLOWER DUCTED UNITS ONLY
After the hood is installed and wired,
engage the calibration process
(our Guaranteed Performance System
Technology to ensure full-rated airflow is
being delivered). Prior to calibration, ensure
that all filters and the duct system are
installed.
CALIBRATION PROCESS Fig. 21.
Open the bottom panel. Hold the calibration
button for 3 seconds and the calibration
button will light up. Close the bottom
panel. The blower will start and begin
the calibration process - which will take
approximately 13 minutes. When calibration
is complete, one of two things will occur:
A. The blower turns off and calibration
button light turns off = Successful
calibration.
B. The blower turns off and calibration
button light blinks continuously = Too
much restriction in the ductwork is
preventing the IQ Blower System™ from
achieving the rated airflow. The blower is
automatically set to maximum intensity.
NOTE: Common items that cause restrictions:
restricted damper flap (backdraft damper, wall
cap, roof cap), too many elbows, duct size
less than 80% of hood outlet, poor transition,
FIG. 21
CALIBRATION
BUTTON
CALIBRATION
LIGHT
use of flex ducting and/or crushed ducting.
Two options are available:
1. Press the calibration button to accept
airflow as is. The IQ Blower System™
is now configured to its highest possible
setting. The blinking calibration light
goes out.
2. Correct duct restriction and repeat the
calibration process.
a. To clear the original calibration data,
hold calibration button for 10 seconds.
The light will blink 3 times to confirm
and the blower configuration will go
back to default settings.
b. Repeat calibration process.
- 14 -
SERVICE PARTS
KEY NO. DESCRIPTION PART NO.
CAS BLOWER ASSEMBLY 06002259
506 BLDC DRIVER 97019431
67 WIRES 06102601
202 WIRE CLAMP 03292290
415 BUSHING 03202288
IME ELECTRICAL INSTALLATION ASSEMBLY 06145222
67A WIRES 06102598
115 FEEDER CABLE CONNECTION BOX E3350233
415 BUSHING 03292596
116 FEEDER CABLE CONNECTION BOX COVER E3351530
125 UPPER TELESCOPIC SKELETON 08092797
124 BOTTOM TELESCOPIC SKELETON E3404965
64 BOTTOM BRACKET 03115251
507 CALIBRATION BUTTON ASSEMBLY 06102584
439 GROMMET 02320034
474 LED LIGHT 02300885
250 RING NUT 02011389
AQI SWITCH BOX ASSEMBLY 06102585
343 CLOSURE PANEL 08093076
477 HINGE 02011376
362 DISPLAY VISOR SPRING 02011421
9 GREASE FILTER 08087804
ARU CONNECTION AIR OUTLET SET 08092501
ACR2 REMOTE CONTROL 08999166
HARDWARE 080810994
INSTALLATION INSTRUCTIONS 080813623
Model CC34IQSB
- 15 -
SERVICE PARTS
Model CC34
IQSB
CAS
125
124
474
477
343
250
9
AQI
IME
US-CIRRUS BLDC
64
362
439
507
506
202
ARU
202
116
202
115
415 (03202288)
415 (03202288)
415 (03202288)
(03292596)
415
(03202288)
415
(03202288)
415
(03202288)
415
ACR2
67 (06102601)
67A (06102598)
- 16 -
99045156C
WARRANTY
Limited Warranty
Warranty Period and Exclusions: Broan-NuTone LLC (the “Company”) warrants to the original consumer purchaser
of its product (“you”) that the product (the “Product”) will be free from material defects in the Product or
its workmanship for a period of one (1) year from the date of original purchase.
The limited warranty period for any replacement parts provided by the Company and for any Products repaired
or replaced under this limited warranty shall be the remainder of the original warranty period.
This warranty does not cover fluorescent lamp starters, tubes, halogen and incandescent bulbs, fuses, filters,
ducts, roof caps, wall caps and other accessories for ducting that may be purchased separately and installed
with the Product. This warranty also does not cover (a)normal maintenance and service, (b)normal wear and
tear, (c)any Products or parts which have been subject to misuse, abuse, abnormal usage, negligence, accident,
improper or insufficient maintenance, storage or repair (other than repair by the Company), (d)damage caused
by faulty installation, or installation or use contrary to recommendations or instructions, (e)any Product that
has been moved from its original point of installation, (f)damage caused by environmental or natural elements,
(g)damage in transit, (h)natural wear of finish, (i)Products in commercial or nonresidential use, or (j)damage
caused by fire, flood or other act of God. This warranty covers only Products sold to original consumers in the
United States by the Company or U.S. distributors authorized by the Company.
This warranty supersedes all prior warranties and is not transferable from the original consumer purchaser.
No Other Warranties: This Limited Warranty contains the Company’s sole obligation and your sole remedy
for defective products. The foregoing warranties are exclusive and in lieu of any other warranties, express or
implied. THE COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES, AND DISCLAIMS
AND EXCLUDES ALL WARRANTIES IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. To the extent that applicable law prohibits the
exclusion of implied warranties, the duration of any applicable implied warranty is limited to the period specified
for the express warranty above. Some states do not allow limitations on how long an implied warranty lasts,
so the above limitation may not apply to you. Any oral or written description of the Product is for the sole purpose
of identifying it and shall not be construed as an express warranty.
Whenever possible, each provision of this Limited Warranty shall be interpreted in such manner as to be
effective and valid under applicable law, but if any provision is held to be prohibited or invalid, such provision
shall be ineffective only to the extent of such prohibition or invalidity, without invalidating the remainder of such
provision or the other remaining provisions of the Limited Warranty.
Remedy: During the applicable limited warranty period, the Company will, at its option, provide replacement
parts for, or repair or replace, without charge, any Product or part thereof, to the extent the Company finds
it to be covered by and in breach of this limited warranty under normal use and service. The Company will
ship the repaired or replaced Product or replacement parts to you at no charge. You are responsible for all
costs for removal, reinstallation and shipping, insurance or other freight charges incurred in the shipment of
the Product or part to the Company. If you must send the Product or part to the Company, as instructed by
the Company, you must properly pack the Product or part—the Company is not responsible for damage in transit.
The Company reserves the right to utilize reconditioned, refurbished, repaired or remanufactured Products or
parts in the warranty repair or replacement process. Such Products and parts will be comparable in function
and performance to an original Product or part and warranted for the remainder of the original warranty period.
Exclusion of Damages: THE COMPANY’S OBLIGATION TO PROVIDE REPLACEMENT PARTS, OR REPAIR OR
REPLACE, AT THE COMPANY’S OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS
LIMITED WARRANTY AND THE COMPANY’S SOLE AND EXCLUSIVE OBLIGATION. THE COMPANY SHALL NOT
BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN
CONNECTION WITH THE PRODUCT, ITS USE OR PERFORMANCE.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also
have other rights, which vary from state to state.
This warranty covers only replacement or repair of defective Products or parts thereof at the Company’s main
facility and does not include the cost of field service travel and living expenses.
Any assistance the Company provides to or procures for you outside the terms, limitations or exclusions of this
limited warranty will not constitute a waiver of such terms, limitations or exclusions, nor will such assistance
extend or revive the warranty.
The Company will not reimburse you for any expenses incurred by you in repairing or replacing any defective
Product, except for those incurred with the Company’s prior written permission.
How to Obtain Warranty Service: To qualify for warranty service, you must (a)notify the Company at the
address or telephone number stated below within seven (7)days of discovering the covered defect, (b)give
the model number and part identification and (c)describe the nature of any defect in the Product or part.
At the time of requesting warranty service, you must present evidence of the original purchase date. If you
cannot provide a copy of the original written limited warranty, then the terms of the Company’s most current
written limited warranty for your particular product will control.The most current limited written warranties for
the Company’s products can be found at www.BestRangeHoods.com.
In USA - BEST
®
Hartford, Wisconsin 800-558-1711
In Canada - BEST
®
Drummondville, QC 866-737-7770 www.BestRangeHoods.com
- 17 -
Modèle CC34IQSB
ENGLISH.....................................2
FRANÇAIS.................................17
ESPAÑOL..................................33
Aux États-Unis - BEST Hartford, Wisconsin
Au CANADA - BEST Drummondville, QC, Canada
ENREGISTREZ VOTRE PRODUIT EN LIGNE À : www.BestRangeHoods.com/register
Pour de plus amples informations, visitez www.BestRangeHoods.com
- 18 -
LIRE CES DIRECTIVES ET LES CONSERVER
AVERTISSEMENT
OBSERVEZ LES DIRECTIVES CI-DESSOUS AFIN DE RÉDUIRE LES RISQUES D’INCENDIE,
DE CHOC ÉLECTRIQUE OU DE BLESSURES CORPORELLES :
1. N’utilisez cet appareil que de la manière prévue par le fabricant. Si vous avez des questions,
communiquez avec le fabricant à l’adresse ou au numéro de téléphone indiqués dans la garantie.
2. Avant de procéder à la réparation ou à l’entretien de l’appareil, coupez l’alimentation
du panneau électrique et verrouillez l’interrupteur principal afin d’empêcher que le courant ne soit
accidentellement rétabli. S’il est impossible de verrouiller l’interrupteur principal, fixez solidement
un message d’avertissement, par exemple une étiquette, sur le panneau électrique.
3. La pose de l’appareil et les travaux d’électricité doivent être effectués par des personnes qualifiées
conformément à la réglementation en vigueur, notamment les normes de la construction ayant
trait à la protection contre les incendies.
4. Pour éviter les refoulements, l’apport d’air doit être suffisant pour brûler les gaz produits
par les appareils à combustion et les évacuer dans le conduit de fumée (cheminée). Respectez
les directives du fabricant de l’appareil de chauffage et les normes de sécurité, notamment celles
publiées par la National Fire Protection Association (NFPA), l’American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE) et les codes des autorités locales.
5. Veillez à ne pas endommager le câblage électrique ou d’autres équipements non apparents lors
de la découpe ou du perçage du mur ou du plafond.
6. Les ventilateurs canalisés doivent toujours rejeter l’air à l’extérieur.
7. N’utilisez pas de commande de régime à semi-conducteurs conjointement avec cet appareil.
8. Pour réduire les risques d’incendie, utilisez seulement des conduits en métal.
9. Cet appareil doit être relié à une mise à la terre.
10. Type d’installation non-IC : L’isolant thermique de la maison ne doit pas couvrir le haut de la hotte
et doit être à au moins 76 mm (3 po) du boîtier de tout côté. (Fig. 1)
!
POUR USAGE DOMESTIQUE SEULEMENT
!
MINIMUM 76 MM (3 PO).
PAS D’ISOLANT DANS CETTE
ZONE OMBRÉE.
FIG. 1
- 19 -
!
ATTENTION
1. Pour usage intérieur seulement.
2. Pour réduire les risques d’incendie et évacuer l’air correctement, assurez-vous qu’il est canalisé
à l’extérieur. N’évacuez pas l’air dans des espaces enfermés par des murs ou un plafond
ou dans un grenier, un vide sanitaire ou un garage.
3. Faites attention lorsque vous utilisez des agents nettoyants ou des détergents.
4. Évitez d’utiliser des produits alimentaires pouvant produire des flammes sous la hotte.
5. Pour ventilation générale uniquement. N’utilisez pas cet appareil pour évacuer des matières
ou des vapeurs dangereuses ou explosives.
6. Pour éviter d’endommager les roulements de moteur, de déséquilibrer les pales ou de les rendre
bruyantes, débarrassez l’appareil de la poussière de plâtre, de construction, etc.
7. Le moteur de la hotte est muni d’un dispositif de protection thermique qui coupe automatiquement
le moteur en cas de surchauffe. Il se remet en marche lorsqu’il a refroidi. Faites réparer la hotte
si le moteur continue à fonctionner par intermittence.
8. Pour mieux capter les vapeurs de cuisson, le bas de la hotte doit être au minimum à 122 cm
(48 po) et au maximum à 183 cm (72 po) de la surface de cuisson. Pour les restrictions
s’appliquant au montage, voir la section « Installation de la bride de montage ».
9. Il est recommandé d’avoir deux installateurs, compte tenu de la taille et du poids de cette hotte.
10. La source d’éclairage est conçue pour cette application particulière et peut surchauffer si elle
est réparée par un personnel sans formation. Si une réparation est nécessaire, le produit doit
être retourné à un centre de service agréé pour être examiné ou réparé.
11. Veuillez lire l’étiquette de spécifications du produit pour obtenir plus de renseignements,
notamment sur les exigences.
POUR RÉDUIRE LES RISQUES D’INCENDIE CAUSÉS PAR DE LA GRAISSE SUR LE PLAN
DE CUISSON :
A. Ne laissez jamais les éléments de surface allumés à haute température. Les débordements
peuvent causer de la fumée et occasionner des écoulements de graisse inflammables.
L’huile doit être chauffée graduellement à basse ou à moyenne température.
B. Mettez toujours la hotte en MARCHE lors de la cuisson à feu vif ou lors de la cuisson d’aliments
à flamber (par ex., crêpes Suzette, cerises jubilé, bœuf au poivre flambé).
C. Nettoyez souvent les ventilateurs. Ne laissez pas la graisse s’accumuler sur le ventilateur ou
lesfiltres.
D. Utilisez des casseroles de dimension appropriée. Utilisez toujours une batterie de cuisine adaptée
à la dimension de la surface chauffante.
OBSERVEZ LES CONSIGNES SUIVANTES DE MANIÈRE À RÉDUIRE LES RISQUES DE BLESSURES
CORPORELLES EN CAS D’INCENDIE CAUSÉ PAR DE LA GRAISSE SUR LE PLAN DE CUISSON* :
1. ÉTOUFFEZ LES FLAMMES à l’aide d’un couvercle étanche, d’une tôle à biscuits ou d’un
plateau en métal puis éteignez le brûleur. FAITES ATTENTION DE NE PAS VOUS BRÛLER.
Si les flammes ne s’éteignent pas immédiatement, QUITTEZ LES LIEUX ET APPELEZ LE
SERVICE DES INCENDIES.
2. NE SOULEVEZ JAMAIS UNE CASSEROLE EN FLAMMES - vous pourriez vous brûler.
3. N’UTILISEZ PAS D’EAU, ni de serviettes ou de linges mouillés – une violente explosion de vapeur
pourrait survenir.
4. Utilisez un extincteur SEULEMENT si :
A. Vous savez qu’il est de classe ABC et vous connaissez déjà son mode de fonctionnement.
B. L’incendie n’est pas très important et ne se propage pas.
C. Les pompiers ont été avisés.
D. Vous pouvez combattre l’incendie en faisant dos à une sortie.
* Conseils tirés de la publication de la NFPA « Kitchen Fire Safety Tips ».
- 20 -
FONCTIONNEMENT
Commandes (Fig. 2)
La hotte fonctionne à l’aide de (5) boutons-poussoirs situés sur la hotte et sur la télécommande.
Les couleurs des DEL sont affichées uniquement sur les commandes de la hotte.
FIG. 2
(P1) Interrupteur d’arrêt différé
• Votrehottecomprenduninterrupteurpourl’arrêtdifféréde10minutes.Appuyezunefoispouractiver
la minuterie d’arrêt différé et l’anneau DEL (L1) se met à clignoter en bleu. Le ventilateur continuera
de fonctionner pendant dix minutes. Après dix minutes, le ventilateur s’arrêtera automatiquement.
• Pourannulerl’arrêtdifférédedixminutes,appuyezdenouveausurl’interrupteur.
(P2) Interrupteur d’alarme de filtre
• Après30heuresdefonctionnementduventilateur,l’alarmedefiltres’activeetl’anneauDEL(L1)
se met à clignoter en rouge. Cela indique que les filtres à graisses doivent être nettoyés.
• Unefoisceux-cinettoyés,appuyezsurleboutonderemiseàrodel’indicateurdechangement
de filtre (P2) pendant l’affichage de l’alarme.
(P3) Bouton de réduction de la vitesse du ventilateur et d’arrêt
• Appuyezpourréduirelavitesseduventilateur.Lavitessedeclignotementdel’anneauDEL(L1)
en bleu est fonction du réglage choisi (par ex. : quatre clignotements correspondent au régime
maximal, un clignotement au régime lent, etc.)
• Pourarrêterleventilateur,continuezd’appuyersurl’interrupteur.
(P4) Bouton de mise en marche et d’augmentation de la vitesse du ventilateur
• Appuyezunefoispourmettreleventilateurenmarcheaurégimelepluslent.
• Appuyezdenouveaupouraugmenterlerégimeduventilateur.Lavitessedeclignotementdel’anneau
DEL (L1) en bleu est fonction du réglage choisi (par ex. : quatre clignotements correspondent
au régime maximal, un clignotement au régime lent, etc.)
(P5) Interrupteur d’éclairage
Il allume et éteint l’éclairage.
P1
P2
P3 P4
ANNEAU
DEL L1
P5
+
-
ƒ
¤
P1 : Activer/désactivater l’arrêt différé (10 minutes)
P2 : Remise à zéro de l’indicateur de changement de filtre
P3 : Réduit la vitesse du ventilateur jusqu’à son
(4>3>2>1>ARRÊT)
P4 : Actionne le ventilateur et augmente sa vitesse
(MARCHE>1>2>3>4)
P5 : Allume/éteint l’éclairage.
L1 : Anneau indicateur DEL :
- Hotte en veilleuse : s’allume de couleur verte. S’éteint
30 secondes après que l’on ait appuyé sur une touche
- Moteur en marche : L1 clignote en bleu. La rapidité
du clignotement est fonction du réglage de la vitesse.
- Arrêt différé de 10 minutes : L1 s’allume et clignote en bleu.
- Alarme de filtre activée : L1 s’allume en rouge
Fonction d’arrêt automatique
Si le ventilateur ou l’éclairage reste continuellement allumé pendant 10 heures sans que l’utilisateur
interagisse avec les commandes, la hotte s’arrêtera automatiquement. Appuyez sur tout de bouton
de commande pour remettre la hotte en marche.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

BEST Range Hoods CC34IQSB Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation