Model • Modèle • Modelo
• Owners Use and Care Guide
Guide d’utilisation et soins de Propriètaire
AIR CONDITIONER
CLIMATISEUR
V1 11.10 DM
DAC8010E / DAC8011E
Contents
CAUTION:
PRECAUTION:
Read and follow all safety rules and operat-
ing instructions before first use of this prod-
uct.
Veuillez lire attentivement les consignes de
sécurité et les instructions d’utilisation avant
l’utilisation initiale de ce produit.
CLIMATISEUR
Guide d'utilisation et d'entretien ........................
• Bienvenue
• Consignes de Sécurité Importantes
• Caractéristiques
• Installation
• Consignes d’utilisation
• Soins et Entretien
• Dépannage
• Garantie
2-17
AIR CONDITIONER
Owners Use and Care Guide .............................
Welcome
• Important Safety Information
• Features
• Installation
• Operation Instructions
• Care and Maintenance
• Troubleshooting
• Warranty
Model • Modèle DAC8010E / DAC8011E
18-33
Welcome
Thank you for choosing a Danby appliance to provide you and your family with all of the “Home Comfort” requirements
of your home, cottage, or office. This Owner’s Use and Care Guide will provide you with valuable information necessary
for the proper care and maintenance of your new appliance. If properly maintained, your Danby appliance will give you
many years of trouble free operation. Please take a few moments to read the instructions thoroughly and familiarize
yourself with all of the operational aspects of this appliance.
For easy reference, may we suggest you attach a copy of your sales slip/receipt to this page, along with the following
information, located on the manufacturers nameplate on the side of the unit.
NOTE: THIS UNIT IS NOT DESIGNED FOR “THROUGH-THE-WALL” INSTALLATION.
Model Number:
Serial Number:
Date of Purchase:
This information will be necessary if your unit requires servicing and/or for general inquiries. To contact a Customer
Service Representative, call Danby TOLL FREE: 1-800-263-2629
2
WARNING
Improper connection of the grounding plug can result in risk of
Fire, Electric Shock and/or injury to Persons associated with the
appliance. Check with a qualified service representative if in doubt
that the appliance is proplery grounded.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
ELECTRICAL
SPECIFICATIONS
FOR YOUR SAFETY: Read these instructions carefully before operating the unit.
1) All wiring must comply with local and national electrical codes and must
be installed by a qualified electrician. If you have any questions
regarding the following instructions, contact a qualified electrician.
2) Check available power supply and resolve any wiring problems
BEFORE installing and operating this unit.
3) This 115V air conditioner uses 7 or less nameplate amps and may be
used in any properly wired, general purpose household receptacle. See
Table 1 for specifications for individual branch circuit.
4) For your safety and protection, this unit is grounded through the power
cord plug when plugged into a matching wall outlet. If you are not sure
whether your wall outlet is properly grounded, please consult a qualified
electrician.
5) The wall outlet must match the 3-prong plug on the service cord
supplied with the unit. DO NOT use plug adapters. See Table 2 for
receptacle and fuse information. If it is necessary to use an extension
cord to connect your air conditioner, use an approved “air
conditioner” extension cord only (available at most local hardware
stores).
6) The rating plate on the unit contains electrical and other technical data.
The rating plate is located on the right side of the unit, above the power
cord.
3
TABLE 1
Suggested Individual Branch Circuit
Nameplate Amps *AWG Wire Size
716
AWG- American Wire Gauge
*Based on copper wire at 60°C temperature rating.
TABLE 2
Receptacle and Fuse Types
Rated Volts 125
Amps 15
Wall Outlet
Fuse Size 15
Time Delay Fuse Plug Type
(or Circuit Breaker)
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
ENERGY SAVING TIPS
FOR YOUR SAFETY: Read these instructions carefully before operating the unit.
Your Danby appliance is designed to be highly efficient in energy
savings. Follow these recommendations for greater efficiency.
1) Select a thermostat setting that suits your comfort needs and leave at
that chosen setting.
2) The air filter is very efficient in removing airborne particles. Keep the air
filter clean at all times. (usually cleaned every 2 weeks depending on
indoor air quality).
3) Use drapes, curtains or shades to keep direct sunlight from penetrating
and heating the room, but do not allow drapes or curtains to obstruct
the air flow around the unit.
4) Start your air conditioner before the outdoor air becomes hot and
uncomfortable, to avoid an initial period of discomfort while the unit is
cooling off the room.
5) When outdoor temperatures are cool enough, use HIGH or LOW FAN
only. This circulates indoor air, providing some cooling comfort, and
utilizes less electricity than when operating on a cooling setting.
4
Features
Air FIlter
Exterior
Air Inlet
Cabinet
Interior Air Inlet
Control Panel
Interior Air Outlet
Installation Instructions
CAUTION
Because the compressor is located on the controls side of the unit
(left side), this side will be heavier and more awkward to manipu-
late. Inadequate support on control side of the unit can result in
personal injury and damage to your unit and property. Therefore, it
is recommended that you have someone assist you during the
installation of this unit.
TOOLS NEEDED FOR INSTALLATION:
Screw Drivers: Phillips and flat head.
Power Drill: 1/8” (3.2mm) diameter drill bit.
Pencil
Measuring Tape
Scissors
Carpenters Level
NOTE: Save the shipping carton and packing materials for future storage
or transportation. From carton, remove the plastic bag containing the
installation hardware kit necessary for the installation of your air
conditioner. Please check the contents of hardware kit against the corre-
sponding model check list, prior to installation of the unit. See Fig. 1.
ELECTRIC SHOCK HAZARD
To avoid the possibility of personal
injury, disconnect power to the unit
before installing or servicing.
NOTE: Your Room Air Conditioner is
designed for easy installtion in a single or
double-hung window. This unit is NOT
designed for vertical (slider type) windows
and/or through-the-wall applications.
Installation Instructions
Fig. 1
INSTALLATION
HARDWARE
LOCATION
A) This room air conditioner is designed to fit easily into a single or double
hung window. However, since window designs vary, it may be
necessary to make some modifications for safe, proper installation.
B) Make sure window and frame are structurally sound and free from dry
and rotted wood.
C) For maximum efficiency, install the air conditioner on a side of the
house or building which favours more shade than sunlight. If the unit is
in direct sunlight, it is advisable to provide an awning over the unit.
D) Provide sufficient clearance around the cabinet to allow for ample air
circulation through the unit (See Fig. 2). The rear of the unit should be
outdoors and not in a garage nor inside a building. Keep unit as far
away as possible from obstacles/obstructions and at least 30” above
the floor or ground. Curtains and other objects within a room should be
prevented from blocking the air flow.
E) Be certain the proper electrical outlet is within reach of the installation.
Use only a single outlet circuit rated at 15 amps. All wiring should be in
accordance with local and national electrical codes.
F) DO NOT install unit where leakage of combustible gas is suspected.
Your air conditioner may fail to operate in air containing oils (including
machine oils), sulfide gas, near hot springs, etc.
NOTE: Your unit is designed to evaporate condensation under normal
conditions. However, under extreme humidity conditions, excess conden-
sation may cause basepan to overflow to the outside. The unit should be
installed where condensation run-off cannot drip on pedestrains or neigh-
boring properties.
5
3/4in. (19.1mm)
screws (7)
Safety Lock (1)
3/8in. (9.5mm) screws
(4) *Factory installed
on some models
“L” Shaped
mounting
bracket (1)
* Factory installed
on some models
Sash bracket (2)
Adhesive
Foam Seal(1)
Side Curtain LH (1)
Side Curtain RH (1)
LOCATION
Installation Instructions
Awning
Fence,
wall, or
other
obstacle
Ground
Side
Obstruction
20”
Min
30”
Min
20”
Min
12” Min
Fig. 2
1) Assembly of the Upper Channel to Cabinet.
(Factory installed on some units)
• “L” Shaped Top Channel: Install the “L” shaped channel to the top of the
cabinet as shown in Fig. 3, using four (4) 3/8” screws.
2) Assembly of the Side Curtains to Cabinet.
• Extend the shutter from the shutter frame and slide it into the shutter tabs
on the side channel of the air conditioner, as shown in Fig. 4.
• Slide the shutters into the top (“L” Shaped) and bottom (“U” Shaped)
channels. The shutters are identified (on frame) as left and right.
3) Completing the Installation
• Cut the foam (non adhesive) sealing strip to fit the area of the window sill
that the air conditioner will rest on.
3/8” screws
“L” shaped mounting
bracket
“U” shaped Channel
(Factory Installed)
Slide down into tabs
Shutter tabs
Shutter
Shutter frame
Fig. 3
Fig. 4
6
7
Installation Instructions
3) Completing the Installation (cont)
• Carefully place the air conditioner into the window with the “L” shaped
mounting bracket (on top) positioned in front of the upper window sash.
The bottom of the cabinet should be positioned on the “recessed” portion
of the window frame. Pull the window down until it rests just behind the
front flange of the (top) “L” shaped mounting bracket (See Fig. 5).
• Expand the shutter frames (fully) on each side and secure the top of the
frames to the window sash using one 3/4” screw on each side and one in
the “L” shaped mounting bracket (Fig. 5).
• Secure the shutter clamp on each side of the (lower) shutter and secure
to window sill using one 3/4” screw on each side (Fig. 5).
• Place the second foam sealing strip to fit the opening between the inside
and outside windows, then attach the safety lock to the outside window
frame using one 3/4” screw (See Fig. 6).
PLEASE NOTE: Window applications come in a variety of different styles.
Therefore, it may be necessary to modify or improvise your particular
installation.
Window sash
“L” Shaped
Mounting
Bracket
Shutter clamps
3/4” screws
Fig. 5
Safety Lock
3/4” screw
Foam Seal
Fig. 6
Operating Instructions
KEY PAD FEATURES
8
LED DISPLAY: Displays the following information independently;Set
Temperature, Ambient RoomTemperature and Auto Timer On/Off settings.
POWER: Turns unit On/Off.
MODE: Allows you to scroll through and select the desired operating
mode; Cool , Dry , Fan Only and *Auto .The selected mode will be denot-
ed by the adjacent indicator light.*‘Auto’is a pre-set factory program that
automatically defines the mode (Cool or Dry) and fan speed based on the
set temperature.
FAN SPEED: Select from four different fan settings;Low , Medium ,
High and Auto during Cool and Fan Only mode. Please note: During ‘Dry’
mode the fan speed is automatically defined .
ENERGY SAVER: Automatically cycles the fan on and off while the
compressor is not in use.
TEMP / TIMER CONTROL: Used to increase or decrease
the Temperature setting in 1°C / °F increments, and Auto-Timer On/Off set-
tings in 30min./1hr. increments. Note: This appliance allows you select the
temperature scale to be displayed in either “Celsius” or Fahrenheit”
according to your preference.To change the temperature scale displayed
on the electronic display, press both the “Temp/Timer”adjust arrows simul-
taneously to alternate between “Celsius” & “Fahrenheit”.
CHECK FILTER: The adjacent indicator light will illuminate as a
reminder to clean the air conditioner filter (see page 9) Once the filter has
been cleaned and replaced, depress the Check Filter button in order to
resume operation.
SLEEP MODE: When activated, the current set temperature is gradu-
ally increased over a one (1) hour period then maintained for seven (7)
hours. Once the program is complete, the air conditioner will resume to its
previous set temperature (before sleep mode was activated). This feature
is mean to be used during the night time hours to prevent the room from
getting too cold (while you sleep) and results in less compressor running
time and reduced energy consumption. Sleep mode may be cancelled by
depressing the Sleep Mode button while the program is running.
AUTO-TIMER: Used to initiate the Auto On/ Auto Off timer.
While the Air Conditioner is off (Auto-On):
1) Press the Auto-Timer button once and the adjacent Auto-On indicator
light will illuminate.
2) Use the Temp/Timer control cursors to select a delayed On time of
up to 24 hours.
3) Select the appropriate mode under which you want the unit to operate
(Auto-Cool-Dry-Fan Only)
4) Select the fan speed setting.
5) The time you selected will appear in the LED display.
While the Air Conditioner is on (Auto-Off):
1) Press the Auto-Timer button twice and the adjacent Auto-Off indicator
light will illuminate.
2) Use the Temp/Timer control cursors to select a delayed Off time of up
to 24 hours.
3) The time you selected will appear in the LED display. The Auto On and
Auto Off timer can operate during the same program by defining the
Auto-Off parameters immediately after the Auto On parameters.The
Auto-Timer may be cancelled at any time by turning the unit On/Off.
MODE
Auto
Auto
68
Temp / Timer
Control
Check
Filter
Mode
Selector
Energy
Saver
LED
Display
Auto
Timer
Sleep
Mode
Fan
Speed
Power
Button
Operating Instructions
USING THE REMOTE
CONTROL
Location of the remote controller.
• Use the remote controller within a distance of 5
meters from the appliance, pointing it towards
the receiver. Reception is confirmed by a beep.
O
N
/
O
F
F
M
O
D
E
TE
M
P
U
P
T
E
M
P
D
O
W
N
S
W
I
N
G
F
A
N
T
I
M
E
R
S
L
EEP
5m
CAUTION
The air conditioner will not operate if curtains, doors or other
materials block the signals from the remote controller to the
indoor unit.
Prevent any liquid from falling into the remote controller. Do not
expose the remote controller to direct sunlight or heat.
If the infrared signal receiver on the indoor unit is exposed to
direct sunlight, the air conditioner may not function properly. Use
curtains to prevent the sunlight from falling on the receiver.
If other electrical appliances react to the remote controller, either
move these appliances or call the service depot.
REMOTE CONTROLLER
SPECIFICATIONS
Model
Rated Voltage
Lowest Voltage of
CPU Emitting Signal
Signal Receiving Range
Environment
R15A, R15B, R15C
3.0V(Button cell: CR2025)
2.0V
5m
-5°C ~ 60°C
9
Operating Instructions
ON/OFF
MODE
TEMP
UP
TEMP
DOWN
TIMER
CLEAN
AIR
SLEEP
S
ENERGY
SAVER
FAN
ON/OFF button
TEMP UP button
FAN button
CLEAN AIR button
(on some models)
ENERGY SAVER
button
MODE button
TEMP DOWN button
TIMER button
SLEEP button
Operation starts when
this button is pressed
and stops when the
button is pressed again.
Push this button to
increase the tempera-
ture setting in 1°C
increments to 30°C.
Used to select the fan
speed in three steps:
LOW
MED
HIGH
When this button is
pressed, the ion genera-
tor is energized and will
help remove pollen and
impurities from the air.
Press this button to
activate the Energy sav-
ing mode. Press it again
to stop the funtion.
Each time you press
this button, a mode is
selected in a sequence
that goes from AUTO,
HEAT (cooling and heat-
ing models only) COOL,
DRY, FAN and back to
AUTO.
Push this button to
decrease the indoor
temperature setting in
1°C increments to 17°C.
Push this button to
activate the “Auto
Start” or “Auto Stop”
program from 0-12
hours (1 hour increments)
Press this button to
activate the Sleep
mode. This function is
available on COOL,
HEAT or AUTO mode
only and maintain the
most comfortable
temperature for you.
REMOTE
CONTROLLER
BUTTONS
ON/OFF
MODE
TEMP
UP
TEMP
DOWN
SWING
TIMER
SLEEP
FAN
ON/OFF button
TEMP UP button
FAN button
SWING button
MODE button
TEMP DOWN button
TIMER button
SLEEP button
Operation starts when
this button is pressed
and stops when the
button is pressed again.
Push this button to
increase the tempera-
ture setting in 1°C
increments to 30°C.
Used to select the fan
speed in three steps:
LOW
MED
HIGH
When this button is
pressed, the vertical lou-
vres will swing automati-
cally from side to side.
Press it again to deacti-
vate the "SWING" fea-
ture.
Each time you press
the button, a mode is
selected in a sequence
that goes from AUTO,
HEAT (cooling and heat-
ing models only) COOL,
DRY, FAN and back to
AUTO.
Push this button to
decrease the indoor
temperature setting in
1°C increments to 17°C.
Push this button to
activate the “Auto
Start” or “Auto Stop”
program from 0-12
hours (1 hour increments)
Press this button to
activate the Sleep
mode. Press again to
stop the function. This
function is available on
COOL, HEAT or AUTO
mode only and maintain
the most comfortable
temperature for you.
Models:
R15A
R15B
Models:
R15C
NOTE: Modle R15B does not have
CLEAN AIR feature.
10
Operating Instructions
USING THE REMOTE
CONTROLLER
BUTTONS
3
1
2
ON/OFF
MODE
TEMP
UP
TEMP
DOWN
ENERGY
TIMER
CLEAN
AIR
SLEEP
3
S
SAVER
FAN
AUTO OPERATION
Ensure the unit is plugged in and power is
available.
1) Press the ON/OFF button to start the air
conditioner.
2) Press the mode button and select
AUTO.
3) Press the TEMP UP / DOWN button to
set the desired temperature. The
temperature can be set within a range of
17°C~ 30°C in 1°C increments.
NOTE
1. In the Auto mode, the air conditioner can logically choose the mode of
Cooling, Fan, Heating and Dehumidifying by sensing the difference
between the actual ambient room temperature and the set temperature
on the remote controller.
2. In the Auto mode, you can not switch the fan speed. It has already been
automatically controlled.
3. If the Auto mode is not comfortable for you, the desired mode can be
selected manually.
3
1
2
ON/OFF
MODE
TEMP
UP
TEMP
DOWN
ENERGY
TIMER
CLEAN
AIR
SLEEP
3
4
S
SAVER
FAN
COOLING /HEATING/FAN OPERATION
Ensure the unit is plugged in and power is
available.
1) Press the ON/OFF button to start the air
conditioner.
2) Press the MODE button to cool, heat
(cooling and heating models only) or fan
mode.
3) Press the TEMP UP / DOWN button to
set the desired temperature. The
temperature can be set within a range of
17°C~ 30°C in 1°C increments.
4) Press the FAN button to select the fan
speed in three steps- Low, Med,or High.
NOTE:
In the Fan mode, the setting temperature is not displayed in the remote
controller and you are not able to control the room temperature either. In
this case, only step 1, 3 and 4 may be performed.
3
1
2
ON/OFF
MODE
TEMP
UP
TEMP
DOWN
ENERGY
TIMER
CLEAN
AIR
SLEEP
3
S
SAVER
FAN
DEHUMIDIFYING OPERATION
Ensure the unit is plugged in and power is
available.
1) Press the ON/OFF button to start the air
conditioner.
2) Press the MODE button to select auto.
3) Press the TEMP UP / DOWN button to
set the desired temperature. The
temperature can be set within a range of
17°C~ 30°C in 1°C increments.
NOTE:
In the Dehumidifying mode, you can not switch the fan speed. It has
already been automatically controlled.
11
Operating Instructions
USING THE REMOTE
CONTROLLER
BUTTONS
1
ON/OFF
MODE
TEMP
UP
TEMP
DOWN
SWING
TIMER
SLEEP
FAN
SWING OPERATION
Use the SWING button to adjust the
Left/Right airflow direction.
1) Press this button while the unit is
operational, the vertical louvers
automatically swing right and left
sweeping the cold/hot air alternately to
obtain comfortable cooling/heating.
2) Press the SWING button again to stop
the swing operation.
1
ON/OFF
MODE
TEMP
UP
TEMP
DOWN
ENERGY
TIMER
CLEAN
AIR
SLEEP
S
SAVER
FAN
SLEEP OPERATION
• In this mode, the selected temperature
will increase(in cooling mode) / decrease
(in heating mode) by 2°F 30 minutes after
the mode is selected.
• The temperature will then increase by
another 2°F after an additional 30
minutes.
• This new temperature will be maintained
for 7 hours before it returns to the
originally selected temperature. This ends
the Sleep mode and the unit will continue
to operate as originally programmed.
The Sleep mode program can be
cancelled at any time during operation
by again pressing the Sleep button.
1
ON/OFF
MODE
TEMP
UP
TEMP
DOWN
ENERGY
TIMER
CLEAN
AIR
SLEEP
S
SAVER
FAN
TIMER OPERATION
press the TIMER button can set the Auto-
start and Auto-stop time of the unit.
NOTE:
• To set Auto-start time, the unit must be in
the OFF position.
• To set Auto-stop time, the unit must be in
the ON postion.
To set the Auto-start time.
1. Push the TIMER button when the unit is
off, only the Auto-start feature can be set.
2. Keep pressing the TIMER button, each
press will increase the selected time by
1 hour increments, up to 12 hours.
3. The time can be set in a range of 0~12
hours.
4. After the desired time has established,
wait for about 10 seconds until the
setting temperature reverts back in the
display window of the air conditioner.
This indicates the program is set.
12
Operating Instructions
USING THE REMOTE
CONTROLLER
BUTTONS
1
ON/OFF
MODE
TEMP
UP
TEMP
DOWN
ENERGY
TIMER
CLEAN
AIR
SLEEP
S
SAVER
FAN
TIMER OPERATION
To set the Auto-start time.
1) Push the TIMER button when the unit is
operational, only the Auto-stop feature
can be set.
2) Keep pressing the TIMER button, each
press will increase the selected time by
1 hour increments, up to 12 hours.
3) The time can be set in a range of 0~12
hours.
4) After the desired time has established,
wait for about 10 seconds until the
setting temperature reverts back in the
display window of the air conditioner.
This indicates the program is set.
NOTE:
To cancel the TIMER setting, push the TIMER button until 0 hour is
displayed on the LCD window of the air conditioner.
1
ON/OFF
MODE
TEMP
UP
TEMP
DOWN
ENERGY
TIMER
CLEAN
AIR
SLEEP
S
SAVER
FAN
CLEAN AIR OPERATION
When this button is pushed, the ion gener-
ator is energized and will help remove
pollen and impurities from the air. Press it
again to stop the operation.
1
ON/OFF
MODE
TEMP
UP
TEMP
DOWN
ENERGY
TIMER
CLEAN
AIR
SLEEP
S
SAVER
FAN
ENERGY SAVER OPERATION
In this mode, the fan will continue to
run for 3 minutes after the compressor
shuts off. The fan then cycles on for 2
minutes at 10 minute intervals until the
room temperature is above the set
temperature, at which time the compressor
turns back on and cooling stars.
13
Operating Instructions
CHANGING THE
BATTERIES ON THE
REMOTE
CR2025
CR
2025
1
2
1
2
+
A
B
The remote controller is powered by
one button cell housed in the rear part
and protected by a cover. Remove the
button cell according to the arrow
marked at the back of the remote
controller.
1. Slightly press “A” position
according to the number 1
arrow direction by your
forefinger.
2. Press “B” position and pull it
according to the number 2
arrow direction by your
thumb.
3. The above step 1 and 2
should be done simultaneously
to slide the button cell out.
1
2
1
2
+
14
Care and Maintenance
CLEAING
When cleaning the air conditioner, be sure to turn the SELECTOR knob to
the “OFF” position and disconnect the power cord from the electrical
outlet.
1) DO NOT use gasoline, benzene, thinner, or any other chemicals to
clean this unit, as these substances may cause damage to the finish
and deformation of plastic parts.
2) Never attempt to clean the unit by pouring water directly over any of the
surface areas, as this will cause deterioration of electrical components
and wiring insulation.
15
AIR FILTER
If the air filter becomes clogged with dust, air flow is obstructed and
reduces efficiency. The air filter should be cleaned every 2 weeks.
AIR FILTER REMOVAL:
The air filter is located behind the air intake front grill. To remove the air
filter, grasp the filter handle on the front of the gril and slide it out to the
right.
To reinstall the air filter, reverse the above procedures. The air filter must
be vacuumed or washed by hand in warm water. Dry thoroughly before
re-installing.
CLEANING AIR FILTER:
1) Use a vacuum cleaner with soft brush attachment
2) Wash the filter in lukewarm water below 40°C (104°F): To get best
results, wash with soapy water or a neutral cleaning agent.
3) Rinse the filter with clean water and dry thoroughly before re-installing.
IMPORTANT
DO NOT forget to install the air filter. If the air conditioner is left to
operate without the air filter, dust is not removed from the room air
and may result in machine failure. When the air inlet grill and cabi-
net are dirty, wipe with lukewarm water (below 40°C). Use of a mild
detergent is recommended.
END OF SEASON
CARE
1) Operate the fan alone for half a day to dry out the inside of the unit.
2) Turn off power and remove plug from wall socket.
3) Clean filter.
4) Store (covered) air conditioner in a dry location.
CAUTION
When installing and/or removing the air conditioner from the win-
dow, ensure that caution is taken to prevent it from falling
backward. It is recommended that installation or removal of the air
conditioner is done with assistance to prevent injury to persons or
damage to the unit or property.
PROBLEM POSSIBLE CAUSE SOLUTIONS
1) Air conditioner will not
operate.
• No power to the unit.
Check connection of power cord to power
source.
• Check fuse or circuit breaker.
• Set SELECTOR SWITCH to position other
than “OFF”.
• The power cord “RESET” button must always
be pushed in (engaged) for correct operation.
2) Inefficient or no cooling.
• Dirty air filter.
• Unit size inappropriate for application.
• Blocked air flow.
• Power interruption, settings changed
too quickly, or compressor overload
tripped.
• Clean/replace air filter.
• Check with dealer to determine proper unit
capacity for application.
• Remove obstruction from grill or outdoor
louvres.
• Turn the unit off and wait 5 minutes before
attempting to restart.
3) Noisy unit.
• Loose parts.
• Inadequate support.
• Tighten loose parts.
• Provide additional support to unit.
4) Odors.
• Formation of mold, mildew, or algae on
wet surfaces.
• Clean unit thoroughly.
• Place algaecide tablet in base pan.
5) Water dripping outside. • Hot and humid weather.
• Condensation run-off is normal under these
conditions.
6) Water dripping inside.
• Unit is not properly angled to allow
water to drain outside.
• Unit must be installed on an angle for proper
condensation run-off. Check the unit and
make any adjustments.
7) Ice or frost build-up
• Low outside temperature.
• Unit air filter is dirty.
• When outdoor temperature is approximately
18.3°C (65°F) or below, frost may form
when unit is in cooling mode. Switch unit to
FAN (only) operation until frost melts.
• Remove and clean filter.
Troubleshooting
Occasionally a problem may arise that is minor in nature, and a service call may not be neccessary. Use this trou-
bleshooting guide for a possible solution. If the unit continues to operate improperly, call an authorized service depot or
Danby’s Toll Free Number 1-800-263-2629 for assistance.
PROBLEM
POSSIBLE CAUSE SOLUTION
16
NOTES:
1) If circuit breaker is tripped repeatedly, or fuse is blown more than once, contact a qualified technician.
2) When unit is installed using proper installation steps, unit is properly tipped toward the outdoors to allow for
condensation run-off.
LIMITED IN-HOME APPLIANCE WARRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating
conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter
“Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided.
First Year
During the first twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s
option, at no charge to the ORIGINAL purchaser.
To obtain
Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any appliance
Service
requiring service outside the limited boundaries of “In Home Service” ,
it will be the consumer’s responsibility to transport the appliance
(at their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Service”
below. Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service
must be performed by a qualified service technician.
If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial application, all
obligations of Danby under this warranty shall be void.
Boundaries of
If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be
In Home Service
delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualified and certified for
warranty service by Danby. Transportation charges to and from the service location are not protected by this warranty and are the
responsibility of the purchaser.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other contents of this appliance, whether
due to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, made or intended by Danby or its
authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditions, representations or guarantees
under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall not be responsible for any damages
to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction of the unit and by the purchase of
the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or property caused by the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
1) Power failure.
2) Damage in transit or when moving the appliance.
3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.
4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating conditions
(extremely high or low room temperature).
5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc.
7) Service calls resulting in customer education.
8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for outdoor application).
Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our
AUTHORIZED SERVICE DEPOT.
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
04/09
1-800-263-2629
Warranty Service
In-home
BIENVENUE
Nous vous remercions d’avoir choisi un climatiseur de chambre Danby pour refroidir votre logement. Ce manuel d’utili-
sation et d’entretien fournit les renseignements nécessaires pour prendre soin et entretenir votre nouveau climatiseur de
chambre. S’il est adéquatement entretenu, votre climatiseur vous donnera de nombreuses années d’utilisation sans
problème. Pour éviter toute difficulté d’installation, veuillez lire les présentes instructions, complètement, avant d’installer
et de faire fonctionner votre appareil.
À titre de référence, vous pouvez agrafer à cette page une copie de votre fiche d’achat de l’appareil. Inscrivez les ren-
seignements suivants fournis (sur la plaque signalétique du fabricant sur le sur le côté de l'unité). Vous aurez besoin de
ces renseignements si vous contactez un représentant du Service à la clientèle.
REMARQUE: CET APPAREIL N’A PAS ÉTÉ CONÇU POUR UNE INSTALLATION À TRAVERS UNE PAROI.
Numéro de modèle :
Numéro de série :
Date d’achat :
Ces renseignements seront requis si le service est demandé et/ou si vous désirez obtenir des renseignements supplé-
mentaires. Pour consulter un Représentant du service à la clientèle, composez le NUMÉRO D’APPEL SANS
FRAIS suivant: (1-800-263-2629)
18
MISE EN GARDE:
Ne laissez pas un climatiseur de chambre sans surveillance dans
un espace où se trouvent des gens ou des animaux qui ne peuvent
pas réagir à un appareil défaillant. Un appareil défaillant peut
causer une surchauffe extrême ou entraîner la mort dans un tel
espace confiné et sans surveillance.
Consignes de sécurité important
LISEZ TOUTE L'INFORMATION DE SÉCURITÉ AVANT UTILISATION
POUR VOTRE SÉCURITÉ: Lire attentivement ces instructions avant d'utiliser l'appareil.
SPECIFICATIONS
ELECTRIQUE
1) Tous les câblages doivent être conformes aux codes électriques locaux
et nationaux et doivent être installés par un électricien qualifié. Si vous
avez la moindre question au suject des instructions ci-dessous,
contactez un électricien qualifié.
2) Vérifiez la fourniture d’alimentation électrique disponsible et résolvez
tout problème de câblage AVANT d’installer et de faire fonctionner cet
appareil.
3) Ce climatiseur à 115V utilise 7 ampères ou moins de puissance
nominale et peut être utilisé dans toute prise de courant domestique de
but général adéquatement câblée. Voir le Tableau 1 pour les
spécifications pour circuit de dérivation individuel.
4) Pour votre sécurité et votre protection, cet appareil est mis à la masse
par la fiche du cordon d’alimentation lorsqu’elle est branchée dans une
prise murale qui lui correspond. Si vous n’êtes pas certain que votre
prise de courant murale est mise à la masse adéquatement, veuillez
consulter un électricien qualifié.
5) La prise murale doit correspondre à la fiche à 3 broches sur le cordon
de service fourni avec l’appareil. N’utilisez PAS de fiches d’adaptation.
Voir Tableau 2 pour les renseignements sur les prises de courant et les
fusibles. S’il est nécessaire d’utiliser une rallonge électrique pour
brancher votre climatiseur, utilisez une rallonge électrique approuvée
pour «climatiseur», exclusivement (disponsible dans la plupart des
magasins locaux de quincaillerie).
6) La plaque signalétique sur l’appareil contient des données électriques
et techniques; elle se trouve sur le côté droit de l’appareil, au-dessus du
cordon d’alimentation.
TABLEAU 2
Types de fusibles et de réceptacles
Tension nominale 125
Ampères 15
Prise de courant
Intensité de fusible 15
Fusible temporisé Type fiche
(ou disjoncteur de circuit)
TABLEAU 1
Circuit de distribution individuel suggéré
Ampères de plaque d’identification Calibre de fil AWG*
716
AWG – American Wire Gauge (Calibre de fil américain)
*Basé sur le fil en cuivre à une température nominale de 60°C
19
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

Danby Air Conditioner DAC8010E Manuel utilisateur

Catégorie
Climatiseurs split-system
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues