Century INVERTER ARC 230 Manuel utilisateur

Catégorie
Système de soudage
Taper
Manuel utilisateur

Ce manuel convient également à

INVERTER ARC 230
OPERATOR’S MANUAL
IM10008
August, 2009
Safety Depends on You
Century® arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be careful.
For use with machines having Code Numbers:
11566
Copyright © Lincoln Global Inc.
Century Equipment
2345 Murphy Blvd. Gainesville, GA 30504 TEL: 866-236-0044
THANK YOU FOR SELECTING
A QUALITY PRODUCT BY
LINCOLN ELEC TRIC.
PLEASE EXAMINE CARTON AND EQUIPMENT FOR
DAMAGE IMMEDIATELY
When this equipment is shipped, title passes to the purchaser
upon receipt by the carrier. Consequently, claims for material
damaged in shipment must be made by the purchaser against the
transportation company at the time the shipment is received.
SAFETY DEPENDS ON YOU
Lincoln arc welding and cutting equipment is designed and built
with safety in mind. However, your overall safety can be increased
by proper installation ... and thoughtful operation on your part.
DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT
WITHOUT READING THIS MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED THROUGHOUT. And, most importantly,
think before you act and be careful.
This statement appears where the information must be followed
exactly to avoid serious personal injury or loss of life.
This statement appears where the information must be followed
to avoid minor personal injury or damage to this equipment.
KEEP YOUR HEAD OUT OF THE FUMES.
DON’T get too close to the arc.
Use corrective lenses if necessary
to stay a reasonable distance
away from the arc.
READ and obey the Safety Data
Sheet (SDS) and the warning label
that appears on all containers of
welding materials.
USE ENOUGH VENTILATION or
exhaust at the arc, or both, to
keep the fumes and gases from
your breathing zone and the general area.
IN A LARGE ROOM OR OUTDOORS, natural ventilation may be
adequate if you keep your head out of the fumes (See below).
USE NATURAL DRAFTS or fans to keep the fumes away
from your face.
If you de velop unusual symptoms, see your supervisor.
Perhaps the welding atmosphere and ventilation system
should be checked.
WEAR CORRECT EYE, EAR &
BODY PROTECTION
PROTECT your eyes and face with welding helmet
properly fitted and with proper grade of filter plate
(See ANSI Z49.1).
PROTECT your body from welding spatter and arc
flash with protective clothing including woolen
clothing, flame-proof apron and gloves, leather
leggings, and high boots.
PROTECT others from splatter, flash, and glare
with protective screens or barriers.
IN SOME AREAS, protection from noise may be appropriate.
BE SURE protective equipment is in good condition.
Also, wear safety glasses in work area
AT ALL TIMES.
SPECIAL SITUATIONS
DO NOT WELD OR CUT containers or materials which previously
had been in contact with hazardous substances unless they are
properly cleaned. This is extremely dangerous.
DO NOT WELD OR CUT painted or plated parts unless special
precautions with ventilation have been taken. They can release
highly toxic fumes or gases.
Additional precautionary measures
PROTECT compressed gas cylinders from excessive heat,
mechanical shocks, and arcs; fasten cylinders so they cannot fall.
BE SURE cylinders are never grounded or part of an
electrical circuit.
REMOVE all potential fire hazards from welding area.
ALWAYS HAVE FIRE FIGHTING EQUIPMENT READY FOR
IMMEDIATE USE AND KNOW HOW TO USE IT.
WARNING
CAUTION
Safety 01 of 04 - 5/16/2018
SECTION A:
WARNINGS
CALIFORNIA PROPOSITION 65 WARNINGS
WARNING: Breathing diesel engine exhaust
exposes you to chemicals known to the State
of California to cause cancer and birth defects,
or other reproductive harm.
Always start and operate the engine in a
well-ventilated area.
If in an exposed area, vent the exhaust to the outside.
Do not modify or tamper with the exhaust system.
Do not idle the engine except as necessary.
For more information go to
www.P65 warnings.ca.gov/diesel
WARNING: This product, when used for welding or
cutting, produces fumes or gases which contain
chemicals known to the State of California to cause
birth defects and, in some cases, cancer. (California
Health & Safety Code § 25249.5 et seq.)
WARNING: Cancer and Reproductive Harm
www.P65warnings.ca.gov
ARC WELDING CAN BE HAZARDOUS. PROTECT
YOURSELF AND OTHERS FROM POSSIBLE SERIOUS
INJURY OR DEATH. KEEP CHILDREN AWAY.
PACEMAKER WEARERS SHOULD CONSULT WITH
THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For
additional safety information, it is strongly recommended
that you purchase a copy of “Safety in Welding & Cutting -
ANSI Standard Z49.1” from the American Welding Society,
P.O. Box 351040, Miami, Florida 33135 or CSA Standard
W117.2-1974. A Free copy of “Arc Welding Safety” booklet
E205 is available from the Lincoln Electric Company,
22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION,
MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
FOR ENGINE POWERED
EQUIPMENT.
1.a. Turn the engine off before troubleshooting
and maintenance work unless the
maintenance work requires it to be running.
1.b. Operate engines in open, well-ventilated areas or vent the engine
exhaust fumes outdoors.
1.c. Do not add the fuel near an open flame welding
arc or when the engine is running. Stop the
engine and allow it to cool before refueling to
prevent spilled fuel from vaporizing on contact
with hot engine parts and igniting. Do not spill fuel when filling
tank. If fuel is spilled, wipe it up and do not start engine until
fumes have been eliminated.
1.d. Keep all equipment safety guards, covers
and devices in position and in good repair.
Keep hands, hair, clothing and tools away
from V-belts, gears, fans and all other
moving parts when starting, operating or
repairing equipment.
1.e. In some cases it may be necessary to remove safety guards to
perform required maintenance. Remove guards only when
necessary and replace them when the maintenance requiring
their removal is complete. Always use the greatest care when
working near moving parts.
1.f. Do not put your hands near the engine fan. Do not attempt to
override the governor or idler by pushing on the throttle control
rods while the engine is running.
1.g. To prevent accidentally starting gasoline engines while turning
the engine or welding generator during maintenance work,
disconnect the spark plug wires, distributor cap or magneto wire
as appropriate.
1.h. To avoid scalding, do not remove the radiator
pressure cap when the engine is
hot.
ELECTRIC AND
MAGNETIC FIELDS MAY
BE DANGEROUS
2.a. Electric current flowing through any conductor
causes localized Electric and Magnetic Fields (EMF).
Welding current creates EMF fields around welding cables
and welding machines
2.b. EMF fields may interfere with some pacemakers, and
welders having a pacemaker should consult their physician
before welding.
2.c. Exposure to EMF fields in welding may have other health effects
which are now not known.
2.d. All welders should use the following procedures in order to
minimize exposure to EMF fields from the welding circuit:
2.d.1. Route the electrode and work cables together - Secure
them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and work
cables. If the electrode cable is on your right side, the
work cable should also be on your right side.
2.d.4. Connect the work cable to the workpiece as close as pos-
sible to the area being welded.
2.d.5. Do not work next to welding power source.
SAFETY
Safety 02 of 04 - 5/16/2018
ELECTRIC SHOCK
CAN KILL.
3.a. The electrode and work (or ground) circuits are
electrically “hot” when the welder is on. Do
not touch these “hot” parts with your bare skin or wet clothing.
Wear dry, hole-free gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation.
Make certain the insulation is large enough to cover your full area
of physical contact with work and ground.
In addition to the normal safety precautions, if
welding must be performed under electrically
hazardous conditions (in damp locations or while
wearing wet clothing; on metal structures such as
floors, gratings or scaffolds; when in cramped
positions such as sitting, kneeling or lying, if there
is a high risk of unavoidable or accidental contact
with the workpiece or ground) use the following
equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode,
electrode reel, welding head, nozzle or semiautomatic welding
gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical
connection with the metal being welded. The connection should
be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical (earth)
ground.
3.f. Maintain the electrode holder, work clamp, welding cable and
welding machine in good, safe operating condition. Replace
damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of electrode
holders connected to two welders because voltage
between the
two can be the total of the open circuit voltage of both
welders.
3.i. When working above floor level, use a safety belt to protect
yourself from a fall should you get a shock.
3.j. Also see It ems 6.c. and 8.
ARC RAYS CAN BURN.
4.a. Use a shield with the proper filter and cover plates to protect your
eyes from sparks and the rays of the arc when welding or
observing open arc welding. Headshield and filter lens should
conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant material
to protect your skin and that of your helpers from the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable
screening and/or warn them not to watch the arc nor expose
themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES
CAN BE DANGEROUS.
5.a. Welding may produce fumes and gases
hazardous to health. Avoid breathing these
fumes and gases. When welding, keep your head out of the fume.
Use enough ventilation and/or exhaust at the arc to keep fumes
and gases away from the breathing zone. When welding
hardfacing (see instructions on container or SDS)
or on lead or cadmium plated steel and other
metals or coatings which produce highly toxic
fumes, keep exposure as low as possible and
within applicable OSHA PEL and ACGIH TLV limits
using local exhaust or mechanical ventilation
unless exposure assessments indicate otherwise.
In confined spaces or in some circumstances,
outdoors, a respirator may also be required.
Additional precautions are also required when
welding
on galvanized steel.
5. b. The operation of welding fume control equipment is affected by
various factors including proper use and positioning of the
equipment, maintenance of the equipment and the specific
welding procedure and application involved. Worker exposure
level should be checked upon installation and periodically
thereafter to be certain it is within applicable OSHA PEL and
ACGIH TLV limits.
5.c. Do not weld in locations near chlorinated hydrocarbon vapors
coming from degreasing, cleaning or spraying operations. The
heat and rays of the arc can react with solvent vapors to form
phosgene, a highly toxic gas, and other irritating products.
5.d. Shielding gases used for arc welding can displace air and
cause
injury or death. Always use enough ventilation, especially in
confined areas, to insure breathing air is safe.
5.e. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the
Safety Data Sheet (SDS) and follow your employer’s safety
practices. SDS forms are available from your welding
distributor or from the manufacturer.
5.f. Also see item 1.b.
SAFETY
Safety 03 of 04 - 5/16/2018
WELDING AND CUTTING
SPARKS CAN CAUSE
FIRE OR EXPLOSION.
6.a. Remove fire hazards from the welding area. If
this is not possible, cover them to prevent the welding sparks
from starting a fire. Remember that welding sparks and hot
materials from welding can easily go through small cracks and
openings to adjacent areas. Avoid welding near hydraulic lines.
Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site, special
precautions should be used to prevent hazardous situations.
Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1)
and the operating information for the equipment being used.
6.c. When not welding, make certain no part of the electrode circuit is
touching the work or ground. Accidental contact can cause
overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the
proper steps have been taken to insure that such procedures
will not cause flammable or toxic vapors from substances inside.
They can cause an explosion even though they have been
“cleaned”. For information, purchase “Recommended Safe
Practices for the Preparation for Welding and Cutting of
Containers and Piping That Have Held Hazardous Substances”,
AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or
welding. They may explode.
6.f. Sparks and spatter are thrown from the welding arc. Wear oil free
protective garments such as leather gloves, heavy shirt, cuffless
trousers, high shoes and a cap over your hair. Wear ear plugs
when welding out of position or in confined places. Always wear
safety glasses with side shields when in a welding area.
6.g. Connect the work cable to the work as close to the welding area
as practical. Work cables connected to the building framework or
other locations away from the welding area increase the
possibility of the welding current passing through lifting chains,
crane cables or other alternate circuits. This can create fire
hazards or overheat lifting chains or cables until they fail.
6.h. Also see item 1.c.
6.I. Read and follow NFPA 51B “Standard for Fire Prevention During
Welding, Cutting and Other Hot Work”, available from NFPA, 1
Batterymarch Park, PO box 9101, Quincy, MA 022690-9101.
6.j. Do not use a welding power source for pipe thawing.
CYLINDER MAY EXPLODE IF
DAMAGED.
7.a. Use only compressed gas cylinders containing
the correct shielding gas for the process used
and properly operating regulators designed for
the gas and pressure used. All hoses, fittings,
etc. should be suitable for the application and
maintained in good condition.
7.b. Always keep cylinders in an upright position securely chained to
an undercarriage or fixed support.
7.c. Cylinders should be located:
Away from areas where they may be struck or subjected
to physical damage.
A safe distance from arc welding or cutting operations
and any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other
electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet
when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand tight
except when the cylinder is in use or connected for use.
7.g. Read and follow the instructions on compressed gas cylinders,
associated equipment, and CGA publication P-l, “Precautions for
Safe Handling of Compressed Gases in Cylinders,” available from
the Compressed Gas Association, 14501 George Carter Way
Chantilly, VA 20151.
FOR ELECTRICALLY
POWERED EQUIPMENT.
8.a. Turn off input power using the disconnect
switch at the fuse box before working on
the equipment.
8.b. Install equipment in accordance with the U.S. National Electrical
Code, all local codes and the manufacturer’s recommendations.
8.c. Ground the equipment in accordance with the U.S. National
Electrical Code and the manufacturer’s recommendations.
Refer to
http://www.lincolnelectric.com/safety
for additional safety information.
SAFETY
Safety 04 of 04 - 5/16/2018
iv
SAFETY
iv
Mar. ‘93
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions
et les précautions de sûreté specifiques qui parraissent dans ce
manuel aussi bien que les précautions de sûreté générales suiv-
antes:
Sûreté Pour Soudage A L’Arc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à l’électrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours
tout contact entre les parties sous tension et la peau nue
ou les vétements mouillés. Porter des gants secs et sans
trous pour isoler les mains.
b. Faire trés attention de bien s’isoler de la masse quand on
soude dans des endroits humides, ou sur un plancher
metallique ou des grilles metalliques, principalement dans
les positions assis ou couché pour lesquelles une grande
partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble
de soudage et la machine à souder en bon et sûr état
defonctionnement.
d.Ne jamais plonger le porte-électrode dans l’eau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à souder
parce que la tension entre les deux pinces peut être le
total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions
pour le porte-électrode s’applicuent aussi au pistolet de
soudage.
2. Dans le cas de travail au dessus du niveau du sol, se protéger
contre les chutes dans le cas ou on recoit un choc. Ne jamais
enrouler le câble-électrode autour de n’importe quelle partie
du corps.
3. Un coup d’arc peut être plus sévère qu’un coup de soliel,
donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi qu’un verre blanc afin de se protéger les yeux du ray-
onnement de l’arc et des projections quand on soude ou
quand on regarde l’arc.
b. Porter des tements convenables afin de proger la
peau de soudeur et des aides contre le rayonnement de
l‘arc.
c. Protéger lautre personnel travaillant à proximité au
soudage à l’aide d’écrans appropriés et non-inflammables.
4. Des gouttes de laitier en fusion sont émises de larc de
soudage. Se protéger avec des vêtements de protection libres
de l’huile, tels que les gants en cuir, chemise épaisse, pan-
talons sans revers, et chaussures montantes.
5. Toujours porter des lunettes de sécurité dans la zone de
soudage. Utiliser des lunettes avec écrans lateraux dans les
zones où l’on pique le laitier.
6. Eloigner les matériaux inflammables ou les recouvrir afin de
prévenir tout risque d’incendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de
la masse. Un court-circuit accidental peut provoquer un
échauffement et un risque d’incendie.
8. S’assurer que la masse est connectée le plus prés possible
de la zone de travail qu’il est pratique de le faire. Si on place
la masse sur la charpente de la construction ou dautres
endroits éloignés de la zone de travail, on augmente le risque
de voir passer le courant de soudage par les chaines de lev-
age, câbles de grue, ou autres circuits. Cela peut provoquer
des risques d’incendie ou d’echauffement des chaines et des
câbles jusqu’à ce qu’ils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage.
Ceci est particuliérement important pour le soudage de tôles
galvanisées plombées, ou cadmiées ou tout autre tal qui
produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant
dopérations de dégraissage, nettoyage ou pistolage. La
chaleur ou les rayons de l’arc peuvent réagir avec les vapeurs
du solvant pour produire du phosgéne (gas fortement toxique)
ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté, voir
le code “Code for safety in welding and cutting” CSA Standard
W 117.2-1974.
PRÉCAUTIONS DE SÛRETÉ POUR
LES MACHINES À SOUDER À
TRANSFORMATEUR ET À
REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de
l’électricité et aux recommendations du fabricant. Le dispositif
de montage ou la piece à souder doit être branché à une
bonne mise à la terre.
2. Autant que possible, I’installation et l’entretien du poste seront
effectués par un électricien qualifié.
3. Avant de faires des travaux à l’interieur de poste, la debranch-
er à l’interrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûre à leur
place.
v
SAFETY
v
Electromagnetic Compatibility (EMC)
Conformance
Products displaying the CE mark are in conformity with European Community Council Directive of 3 May
1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility
(89/336/EEC). It was manufactured in conformity with a national standard that implements a harmonized
standard: EN 60974-10 Electromagnetic Compatibility (EMC) Product Standard for Arc Welding Equipment.
It is for use with other Lincoln Electric equipment. It is designed for industrial and professional use.
Introduction
All electrical equipment generates small amounts of electromagnetic emission. Electrical emission may be
transmitted through power lines or radiated through space, similar to a radio transmitter. When emissions
are received by other equipment, electrical interference may result. Electrical emissions may affect many
kinds of electrical equipment; other nearby welding equipment, radio and TV reception, numerical controlled
machines, telephone systems, computers, etc. Be aware that interference may result and extra precautions
may be required when a welding power source is used in a domestic establishment.
Installation and Use
The user is responsible for installing and using the welding equipment according to the manufacturers
instructions. If electromagnetic disturbances are detected then it shall be the responsibility of the user of the
welding equipment to resolve the situation with the technical assistance of the manufacturer. In some cases
this remedial action may be as simple as earthing (grounding) the welding circuit, see Note. In other cases it
could involve construction of an electromagnetic screen enclosing the power source and the work complete
with associated input filters. In all cases electromagnetic disturbances must be reduced to the point where
they are no longer troublesome.
Note: The welding circuit may or may not be earthed for safety reasons according to national codes.
Changing the earthing arrangements should only be authorized by a person who is compe-
tent to access whether the changes will increase the risk of injury, e.g., by allowing parallel
welding current return paths which may damage the earth circuits of other equipment.
Assessment of Area
Before installing welding equipment the user shall make an assessment of potential electromagnetic prob-
lems in the surrounding area. The following shall be taken into account:
a) other supply cables, control cables, signaling and telephone cables; above, below and adjacent to the
welding equipment;
b) radio and television transmitters and receivers;
c) computer and other control equipment;
d) safety critical equipment, e.g., guarding of industrial equipment;
e) the health of the people around, e.g., the use of pacemakers and hearing aids;
f) equipment used for calibration or measurement
g) the immunity of other equipment in the environment. The user shall ensure that other equipment being
used in the environment is compatible. This may require additional protection measures;
h) the time of day that welding or other activities are to be carried out.
L10093 3-1-96H
vi
SAFETY
vi
Electromagnetic Compatibility (EMC)
The size of the surrounding area to be considered will depend on the structure of the building and other
activities that are taking place. The surrounding area may extend beyond the boundaries of the premises.
Methods of Reducing Emissions
Mains Supply
Welding equipment should be connected to the mains supply according to the manufacturer’s recommenda-
tions. If interference occurs, it may be necessary to take additional precautions such as filtering of the mains
supply. Consideration should be given to shielding the supply cable of permanently installed welding equip-
ment, in metallic conduit or equivalent. Shielding should be electrically continuous throughout its length. The
shielding should be connected to the welding power source so that good electrical contact is maintained
between the conduit and the welding power source enclosure.
Maintenance of the Welding Equipment
The welding equipment should be routinely maintained according to the manufacturer’s recommendations.
All access and service doors and covers should be closed and properly fastened when the welding equip-
ment is in operation. The welding equipment should not be modified in any way except for those changes
and adjustments covered in the manufacturers instructions. In particular, the spark gaps of arc striking and
stabilizing devices should be adjusted and maintained according to the manufacturer’s recommendations.
Welding Cables
The welding cables should be kept as short as possible and should be positioned close together, running at
or close to floor level.
Equipotential Bonding
Bonding of all metallic components in the welding installation and adjacent to it should be considered.
However, metallic components bonded to the work piece will increase the risk that the operator could
receive a shock by touching these metallic components and the electrode at the same time. The operator
should be insulated from all such bonded metallic components.
Earthing of the Workpiece
Where the workpiece is not bonded to earth for electrical safety, not connected to earth because of its size
and position, e.g., ships hull or building steelwork, a connection bonding the workpiece to earth may reduce
emissions in some, but not all instances. Care should be taken to prevent the earthing of the workpiece
increasing the risk of injury to users, or damage to other electrical equipment. Where necessary, the connec-
tion of the workpiece to earth should be made by a direct connection to the workpiece, but in some countries
where direct connection is not permitted, the bonding should be achieved by suitable capacitance, selected
according to national regulations.
Screening and Shielding
Selective screening and shielding of other cables and equipment in the surrounding area may alleviate prob-
lems of interference. Screening of the entire welding installation may be considered for special applications.
1
_________________________
1
Portions of the preceding text are contained in EN 60974-10: “Electromagnetic Compatibility (EMC) prod-
uct standard for arc welding equipment.”
L10093 3-1-96H
viii
viii
TABLE OF CONTENTS
Page
Installation.......................................................................................................................Section A
Technical Specifications.......................................................................................................A-1
Safety Precautions.................................................................................................A-2
Select Suitable Location.......................................................................................................A-2
Stacking................................................................................................................................A-2
Tilting....................................................................................................................................A-2
Input Connections ................................................................................................................A-2
Ground Connection..............................................................................................................A-2
Input Power Connection.......................................................................................................A-2
230V Input............................................................................................................................A-3
Output Connections..............................................................................................................A-3
Stick Welding........................................................................................................................A-3
TIG Welding..........................................................................................................................A-3
________________________________________________________________________________
Operation.........................................................................................................................Section B
Safety Instructions................................................................................................................B-1
General Description..............................................................................................................B-1
Welding Capability................................................................................................................B-1
Limitations ............................................................................................................................B-1
Controls and Operational Features,Front and Rear Control Panel......................................B-2
Stick-Welding Circuit ............................................................................................................B-3
Electric Arc ...........................................................................................................................B-3
Making a Weld (Stick)...................................................................................................B-3, B-4
TIG Welding..........................................................................................................................B-4
Making a TIG Weld...............................................................................................................B-5
________________________________________________________________________
Accessories.....................................................................................................Section C
Optional Accessories and Compatible Equipment.................................................C-1
Factory, Field Installed...........................................................................................C-1
Cable Plugs...........................................................................................................C-1
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Maintenance ....................................................................................................Section D
Safety Precautions ................................................................................................D-1
Routine Maintenance.............................................................................................D-1
________________________________________________________________________
Troubleshooting..............................................................................................Section E
How to Use Troubleshooting Guide.......................................................................E-1
Troubleshooting Guide............................................................................E-2 thru E-3
________________________________________________________________________
Wiring Diagram................................................................................................Section F
________________________________________________________________________
Parts Pages.............................................................................................................P-610
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
A-1
INSTALLATION
INVERTER ARC™ 230
A-1
Input Circuit
230 Vac
Maximum Open Circuit Voltage
9.5Vdc (VRD)
Duty Cycle
30%
Output Current Range
10-155 Amps
INPUT - SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Height Width Length Weight
12.0 in. 6.5 in. 14.6 in. Approx. 22.0 lbs.
305.0 mm 165.0 mm 370.8mm 10.0 kgs.
PHYSICAL DIMENSIONS
TEMPERATURE RANGES
OPERATING TEMPERATURE RANGE
-10°C to +40°C
STORAGE TEMPERATURE RANGE
-25°C to +55°C
RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT
INPUT VOLTAGE /
FREQUENCY (HZ)
230/60
MAXIMUM TIME-DELAY CIRCUIT
BREAKER OR FUSE SIZE (AMPS)
30
TYPE S, SO, ST, STO or EXTRA
HARD USAGE INPUT CORD
3 Conductor, 12 AWG
Input Voltages 60 Hz.
230Vac ± 15%
Rated Input Current
30 Amps @ Rated Output
Output Amps
150A(TIG)
140A (Stick)
Output Volts
16.0 Vdc
25.6 Vdc
Type of Output
DC
TECHNICAL SPECIFICATION INVERTER ARC™ 230
A-2
INSTALLATION
INVERTER ARC™ 230
A-2
Read entire installation section before starting
installation.
SAFETY PRECAUTIONS
ELECTRIC SHOCK can kill.
Only qualified personnel should per-
form this installation.
Disconnect input power by removing
plug from receptacle before working
inside INVERTER ARC™ 230. Allow
machine to sit for 5 minutes
mini-
mum to allow the power capacitors
to discharge before working inside
this equipment.
Insulate yourself from the work and ground.
Always wear dry insulating gloves.
• Always connect the INVERTER ARC 230 to a
power supply grounded according to the National
Electrical Code and local codes.
------------------------------------------------------------
SELECT SUITABLE LOCATION
This machine can operate in harsh environments.
However, it is important that simple preventative
measures are followed to assure long life and reliable
operation:
• This machine must be located where there is free
circulation of clean air without restrictions for air
movement to and from the air vents. Do not cover
the machine with paper, cloth or rags when switched
on.
• Dirt and dust that can be drawn into the machine
should be kept to a minimum.
• This machine has a protection rating of IP21S.
Keep it dry and do not place it on wet ground or in
puddles. Do not use in wet or damp locations. Store
indoors.
• Locate the machine away from radio controlled
machinery. Normal operation may adversely affect
the operation of nearby radio controlled machinery,
which may result in injury or equipment damage.
Read the section on electromagnetic compatibility in
this manual.
• Do not operate in areas with an ambient tempera-
ture greater than 40°C.
STACKING
The INVERTER ARC™ 230 cannot
be stacked.
TILTING
Place the machine directly on a secure, level surface.
Do not place or operate this machine on a surface
with an incline greater than 15° from horizontal. The
machine may topple over if this procedure is not fol-
lowed.
INPUT CONNECTIONS
GROUND CONNECTION
The frame of the welder must be ground-
ed. A ground terminal marked with the
symbol is located on the under panel for
this purpose. See your local and national
electrical codes for proper grounding
methods.
A grounding conductor is supplied in the input
cord, it is important that the supply receptacle
ground is connected.
The welding power source supply cable is pro-
vided with a green or yellow/green wire that must
ALWAYS be earthed. This green or yellow/green
wire must NEVER be used with other voltage
conductors.
• Only install plugs that conform with safety regu-
lations.
------------------------------------------------------------
WARNING
WARNING
INPUT POWER CONNECTION
Check the input voltage, phase, and frequency sup-
plied to this machine before turning it on. The allow-
able input voltage is indicated in the technical specifi-
cation section of this manual and on the rating plate of
the machine. Be sure that the machine is grounded.
Make sure the power available at the input connection
is adequate for normal operation of the machine. The
fuse rating and cable sizes are both indicated in the
technical specification section of this manual.
Fuse the input circuit with time delay fuses marked “D”
or delay type
(1)
circuit breakers. Using fuses or circuit
breakers smaller than recommended may result in
“nuisance” shut-offs from welder inrush currents even
if not welding at high currents.
(1)
Also called “inverse time” or “thermal/magnetic” circuit breakers.
These circuit breakers have a delay in tripping action that
decreases as the magnitude of the current increases.
The INVERTER ARC™ 230 is recommended for use
on an individual branch circuit.
A-3
INSTALLATION
INVERTER ARC™ 230
A-3
OUTPUT CONNECTIONS
A quick disconnect system using Twist-Matecable
plugs is used for the welding cable connections.
Refer to the following sections for more information on
connecting the machine for operation of stick welding
(SMAW) or TIG welding (GTAW).
ELECTRIC SHOCK can kill.
• Keep the electrode holder and cable
insulation in good condition.
• Do not touch electrically live parts or electrode
with skin or wet clothing.
• Insulate yourself from work and ground.
• Turn the input line Switch on the INVERTER
ARC™ 230 off” before connecting or discon-
necting output cables or other equipment.
------------------------------------------------------------
STICK WELDING (SMAW)
First determine the proper electrode polarity for the elec-
trode to be used. Consult the electrode data for this
information. Then connect the output cables to the out-
put terminals of the machine for the selected polarity.
Shown here is the connection method for DC(+) welding.
(See Figure A.1)
Connect the electrode cable to the (+) terminal and the
work clamp to the (-) terminal. Insert the connector with
the key lining up with the keyway and rotate approxi-
mately 1/4 turn clockwise. Do not over tighten.
For DC(-) welding, switch the cable connections at the
machine so that the electrode cable is connected to (-)
and the work clamp is connected to (+).
Work Clamp
Work Cable
Electrode
Holder
FIGURE A.1
WARNING
230V INPUT
The INVERTER ARC™ 230 is provided with a 230V
cable, 6.0ft.(1.8m) in length, with a 50 Amp (NEMA 6-
50P) plug molded onto the cord.
The rated output of the INVERTER ARC 230 is
available when connected to a 30A branch circuit.
When connected to a branch circuit with lower ampac-
ity, lower welding current and duty cycle must be
used. Other loads on the circuit and fuse/circuit break-
er characteristics will affect the available output.
TIG WELDING (GTAW)
This machine does not have a built in Gas Solenoid
so a one piece gas valve TIG Torch is required. A
K960-2 Twist-mate TIG Torch adapter is also required.
Refer to the accessories section for more information
about TIG Torches and required Twist-mate adapter.
Most TIG welding is done with DC(-) polarity shown
here. If DC(+) polarity is necessary switch the cable
connections at the machine. (See Figure A.2)
Connect the torch cable to the (-) terminal of the
machine and the work clamp to the (+) terminal.
Insert the connector with the key lining up with the
keyway and rotate approximately 1/4 turn clockwise.
Do not over tighten. Finally, connect the Twist-mate
adapter gas hose to the gas regulator on the cylinder
of gas to be used.
FIGURE A.2
Work Cable
Work Clamp
Twist-mate Adapter K-960-2
Gas hose to bottle
Gas Valve to
TIG Torch
B-1
OPERATION
INVERTER ARC™ 230
B-1
Read and understand this entire section before
operating your machine.
SAFETY INSTRUCTIONS
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts such
as output terminals or internal wiring.
• Insulate yourself from the work and
ground.
• Always wear dry insulating gloves.
------------------------------------------------------------
------------------------------------------------------------
------------------------------------------------------------
------------------------------------------------------------
Only qualified personnel should operate this equip-
ment. Observe all safety information throughout this
manual.
------------------------------------------------------------
GENERAL DESCRIPTION
The INVERTER ARC™ 230 is a 150 amp arc welding
power source which utilizes single phase input power
to produce constant current output. The welding
response of this Inverter has been optimized for stick
(SMAW) and TIG (GTAW) welding.
WELDING CAPABILITY
The INVERTER ARC 230 is rated at 150 amps
at 30% duty cycle on a ten minute basis. It is capable
of higher duty cycles at lower output currents. If the
duty cycle is exceeded, a thermal protector will shut
off the output until the machine cools.
The INVERTER ARC™ 230 is recommended for the
following Electrode Types and Diameters:
LIMITATIONS
The INVERTER ARC™ 230 is not recommended for
pipe thawing.
WARNING
FUMES AND GASES
can be dangerous.
Keep your head out of fumes.
Use ventilation or exhaust to
remove fumes from breathing
zone.
ARC RAYS
can burn.
Wear eye, ear and body
protection.
WELDING, CUTTING and
GOUGING SPARKS
can cause fire or explosion
Keep flammable material away.
Do not weld, cut or gouge on contain-
ers that have held combustibles.
TYPE
Fleetweld 37
(E6013)
Fleetweld 35
(E6011)
Excalibur 7018 MR
(7018)
5/64
(2.0)
3/32
(2.4)
1/8
(3.2)
5/32
(4.0)
ELECTRODE SIZE
DIA.
in.
(mm)
B-2
OPERATION
B-2
CONTROLS AND OPERATIONAL
FEATURES
FRONT CONTROL PANEL
(See Figure B.1)
1. Output Current Knob: Potentiometer used to
set the output current used during welding. Set the
output according to the type and size of electrode.
2. Power Switch: Turns ON / OFF the input power to
the machine.
3. Welding Mode Switch: Controls the welding mode
of the machine:
Select Stick welding or Lift TIG welding.
• Stick (SMAW):
• Lift TIG (GTAW): When the mode switch is in
the Lift TIG position, the stick welding functions are
disabled and the machine is ready for Lift TIG weld-
ing. Lift TIG is a method of starting a TIG weld by
first pressing the TIG torch electrode on the work
piece in order to create a low current short circuit.
Then, the electrode is lifted from the work piece to
start the TIG arc.
INVERTER ARC™ 230
1
3
4
5
6
2
155
7
8
A
FIGURE B.1
4. Thermal LED: This indicator will turn on when
the machine is overheated and the output has been
disabled. This normally occurs when the duty cycle
of the machine has been exceeded. Leave the
machine on to allow the internal components to
cool. When the indicator turns off, normal operation
is again possible.
5. Negative Quick Disconnect: Negative output con-
nector for the welding circuit.
6. Positive Quick Disconnect: Positive output con-
nector for the welding circuit.
REAR CONTROL PANEL
(See Figure B.2)
7. Input cable: This machine is provided with a
plugged input cord. Connect it to input receptacle.
8. Fan
FIGURE B.2
B-3
OPERATION
B-3
INVERTER ARC™ 230
STICK-WELDING CIRCUIT
(See Figure B.3)
FIGURE B.3
Current flows through the electrode cable and elec-
trode holder to the electrode and across the arc. On
the work side of the arc, the current flows through the
base metal to the work cable and back to the welding
machine. The circuit must be complete for the current
to flow.
To weld, the work clamp must be tightly connected to
clean base metal. Remove paint, rust, etc. as neces-
sary to get a good connection. Connect the work
clamp as close as possible to the area you wish to
weld. Avoid allowing the welding circuit to pass
through hinges, bearings, electronic components or
similar devices that can be damaged.
An electric arc is made between the work and the end
of a small metal rod, the electrode, which is clamped
in a holder and the holder is held by the person doing
the welding. A gap is made in the welding circuit (see
Figure B.3) by holding the tip of the electrode 1/16-
1/8” away from the work or base metal being welded.
The electric arc is established in this gap and is held
and moved along the joint to be welded, melting the
metal as it is moved.
ELECTRIC ARC (Stick-Welding)
(See Figure B.4)
Action that takes place in the electric arc.
FIGURE B.4
This figure closely resembles what is actually seen
during welding. The “arc stream’’ is seen in the middle
of the figure. This is the electric arc created by the
electric current flowing through the space between the
end of the electrode and the work.
The temperature of this arc is about 6000°F (3315°C),
which is more than enough to melt metal. The arc is
very bright, as well as hot, and cannot be looked at
with the naked eye without risking painful injury. A very
dark lens, specifically designed for arc welding, must
be used with a hand or face shield whenever viewing
the arc. The arc melts the base metal and actually
digs into it, much as water through a nozzle on a gar-
den hose digs into the earth. The molten metal forms
a pool or crater and tends to flow away from the arc.
As it moves away from the arc, it cools and solidifies.
A slag forms on top of the weld to protect it during
cooling.
The function of the covered electrode is much more
than simply to carry current to the arc. The electrode
is composed of a core rod of metal with an extruded
chemical covering. The core rod melts in the arc and
tiny droplets of molten metal shoot across the arc into
the molten pool. The electrode provides additional
filler metal for the joint to fill the groove or gap
between the two pieces of the base metal. The cover-
ing also melts or burns in the arc. It has several func-
tions. It makes the arc steadier, provides a shield of
smoke-like gas around the arc to keep oxygen and
nitrogen in the air away from the molten metal, and
provides a flux for the molten pool. The flux picks up
impurities and forms the protective slag.
MAKING A WELD
Insert the bare part of the electrode into the electrode
holder jaws and connect the work clamp to the weld-
ing piece. Make sure to have good electrical contact.
1. Turn the welder on.
2. Lower your welding helmet to protect your face and
eyes.
3. Strike the electrode at the work point on the work-
piece as if striking a match. Do not hit the electrode
on the workpiece, which will damage the stick elec-
trode and make striking an arc difficult. Scratch the
electrode slowly over the metal and you will see
sparks. While scratching, lift the electrode 1/8"
(3.2mm) and the arc will establish.
NOTE: If you stop moving the electrode while scratch-
ing, the electrode will stick.
NOTE: Most beginners try to strike the arc by a fast
jabbing motion down on the plate. Result:
They either stick or their motion is so fast that
they break the arc immediately.
B-4
OPERATION
B-4
4. Immediately after striking the arc try to maintain a
distance from the workpiece that is equivalent to
the diameter of the electrode used. Maintain this
distance as constantly as possible during the weld.
Whenever possible, weld from left to right (if right-
handed). Hold the electrode at a slight angle as
shown. (See Figure B.5)
FIGURE B.5
5. As the electrode burns off the electrode must be fed
to the work to maintain correct arc length. The easi-
est way to tell whether the arc has the correct
length is by listening to its sound. A nice, short arc
has a distinctive, “crackling” sound, very much like
eggs frying in a pan. The incorrect, long arc has a
hollow, blowing or hissing sound.
6. The important thing to watch while welding is the
puddle of molten metal right behind the arc. Do
NOT watch the arc itself. It is the appearance of the
puddle and the ridge where the molten puddle
solidifies that indicate correct welding speed. The
ridge should be approximately 3/8" (9.5mm) behind
the electrode. (See Figure B.6)
FIGURE B.6
Most beginners tend to weld too fast, resulting in a
thin, uneven, wormy looking bead. They are not
watching the molten metal.
IMPORTANT: For general welding it is not necessary
to weave the arc; neither forwards and backwards nor
sideways. Weld along at a steady pace. You will find it
easier.
NOTE: When welding on thin plate, you will find that
you will have to increase the welding speed, whereas
when welding on heavy plate, it is necessary to go
more slowly in order to get good penetration.
7. Once the electrode is burned down move the elec-
trode quickly from the weld to extinguish the arc.
8. Turn the machine off and remove the stub by open-
ing the jaws of the electrode holder and insert a
new electrode.
Note: The welded work piece and electrode stub are
hot after welding. Allow them to cool down
before touching or use pliers to move. Always
make sure the welder is turned off before set-
ting down the Electrode Holder.
TIG Welding (Tungsten Inert Gas Welding)
This machine is capable of direct current (DC) TIG
welding which is suitable for hard metals such as
steel, stainless steel, copper & brass. The TIG
process is good for welding thin materials requiring
very good cosmetic appearance with low heat input
and low spatter. TIG welding uses a tungsten elec-
trode which delivers electrical current to the work
piece by way of an electric arc. Unlike stick welding in
which the electrode is consumed in the arc, the tung-
sten electrode is not consumed. Instead filler metal is
added to the weld by manually dipping a filler rod into
the weld puddle. TIG welding requires a higher skill
level than stick welding and practice is required to
master the technique. For best results a TIG welding
class is suggested or obtaining a book on how to TIG
weld.
TIG welding also requires 100% Argon shielding gas
to shield the arc, preventing porosity in the weld. This
is different than stick welding which has a coating on
the electrode to produce its own shielding. In addi-
tion, a gas regulator, a manual gas valve TIG torch,
torch parts kit, torch adapter and filler metal are
required. Refer to the accessories section of this
manual for an appropriate optional TIG torch, parts kit
and torch adapter. A gas regulator, filler metal and a
bottle of shielding gas are readily available from a
welding gas distributor.
Figure B.7 shows the basic TIG welding set-up:
FIGURE B.7
INVERTER ARC™ 230
WORKPIECE
TUNGSTEN
GAS BOTTLE
WITH REGULATOR
WORK CLAMP
TORCH WITH
GAS VALVE
TIG TORCH
ADAPTER
B-5
OPERATION
B-5
Making a TIG Weld:
1. Connect the work cable to the positive +” output
terminal.
2. Connect the TIG torch to the negative “-“ output ter-
minal.
3. Connect the gas line from the TIG torch adapter to
the gas regulator connected to the gas bottle.
4. Open the gas valve on the gas bottle and adjust the
gas regulator to approximately 20-30 cfm.
5. Set the amperage based on material thickness:
Steel Thickness Amperage Setting
(1/16”) 1.6mm 60-90 Amps
(1/8”) 3.2mm 75-120 Amps
(3/16) 4.8mm 125-150 Amps
6. Turn machine on.
7. Turn the gas valve on the torch to start shielding
gas flowing.
8. Touch the tungsten to the work piece and pause for
a second.
9. Slowly lift the tungsten off the work piece to estalish
the arc. (Note: Rocking the torch back onto the
ceramic shielding cup is an easy way to do this
steadily.)
10. With the torch pointed in the direction of travel
angled about 75 degrees to the work piece slowly
move the torch in the direction of travel. Maintain
about a 1/4 distance from the tungsten to the
work piece while moving. Apply filler metal to the
weld puddle by dipping the filler rod into the weld
puddle allowing it to melt off and being careful not
to touch the filler metal to the tungsten electrode.
11. At the end of the weld lift the TIG torch quickly
away from the work piece to break the arc.
12. Turn off torch gas valve.
13. Turn machine off.
NOTE:
For more detailed information about TIG welding order
“Gas Tungsten Arc Welding Guide Book (JFLF-834)”
from the James F. Lincoln Arc Welding Foundation.
http://www.jflf.org/
INVERTER ARC™ 230
C-1
ACCESSORIES
C-1
OPTIONAL ACCESSORIES
AND COMPATIBLE EQUIPMENT
Factory Installed
Electrical Holder and Cable Assembly
Work Cable and Clamp
Strap Packet
Instruction Manual
Field Installed
PTA-17V TIG Torch -
150 Amp air-cooled compact
and durable Tig Torch with integral gas valve for gas
control at the torch. The following 1-piece cable torches
can be used with a K960-2 adapter:
• K1782-6 (12.50 Ft.) 1-Piece Cable
• K1782-8 (25.0 Ft.) 1-Piece Cable
PTA-9FV TIG Torch - 125 Amp Gas Valve flexible
head torch:
• K1781-7 (25.0 Ft.) 1-Piece Cable
PTA-17FV TIG Torch - 150 Amp Gas Valve flexible
head torch:
• K1782-11 (25.0 Ft.) 1-Piece Cable
• K1782-13 (12.5 Ft.) 1-Piece Ultra Flex Cable
K960-2-TIG Torch Adapter - for connection of PTA-
17V torches (1-piece cable) to power sources without
gas passing through the Twist Mate connection.
CABLE PLUGS
K852-25 - Cable Plug Kit attaches to welding cable to
provide quick disconnect from machine.
TIG Torch Parts Kits - Parts kits are available for the
PTA-9FV and PTA-17 TIG torch. These kits include
back cap, collets, collet bodies, nozzles and tung-
stens.
Order KP508 for PTA-17 torches
Order KP507 for PTA-9 torches
See publication E12.150 for parts kits breakdown.
Cut Length Consumables - TIG welding filler metals
are available for welding stainless steel, mild steel,
aluminum and copper alloys. See Lincoln Electric pub-
lication C9.10.
INVERTER ARC™ 230
D-1
MAINTENANCE
D-1
INVERTER ARC™ 230
SAFETY PRECAUTIONS
ELECTRIC SHOCK can kill.
• Have an electrician install and
service this equipment.
• Turn the input power off at the
fuse box, disconnect supply lines
and allow machine to sit for five
minutes minimum to allow the
power capacitors to discharge
before working inside this equip-
ment.
• Do not touch electrically hot parts.
------------------------------------------------------------
ROUTINE MAINTENANCE
The frequency of the maintenance operations may
vary in accordance with the working environment.
Any noticeable damage should be reported immedi-
ately.
• Check cables and connections integrity. Replace, if
necessary.
• Clean the power source inside by means of low -
pressure compressed air.
• Keep the machine clean. Use a soft dry cloth to
clean the external case, especially the airflow inlet /
outlet louvers.
Do not open this machine and do not introduce
anything into its openings. Power supply must be
disconnected from the machine before each main-
tenance and service. After each repair, perform
proper tests to ensure safety.
Power supply must be disconnected from the
machine before each maintenance and service.
Always use gloves in compliance with the safety
standards.
------------------------------------------------------------
WARNING
WARNING
CAUTION
E-1
TROUBLESHOOTING
E-1
INVERTER ARC™ 230
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
CAUTION
This Troubleshooting Guide is provided to help you
locate and repair possible machine malfunctions.
Simply follow the three-step procedure listed below.
Step 1. LOCATE PROBLEM (SYMPTOM).
Look under the column labeled “PROBLEM (SYMP-
TOMS)”. This column describes possible symptoms
that the machine may exhibit. Find the listing that
best describes the symptom that the machine is
exhibiting.
Step 2. POSSIBLE CAUSE.
The second column labeled “POSSIBLE CAUSE” lists
the obvious external possibilities that may contribute
to the machine symptom.
Step 3. RECOMMENDED COURSE OF ACTION
This column provides a course of action for the
Possible Cause, generally it states to contact your
local Authorized Field Service Facility.
If you do not understand or are unable to perform the
Recommended Course of Action safely, contact your
local Authorized Field Service Facility.
HOW TO USE TROUBLESHOOTING GUIDE
Service and Repair should only be performed by Factory Trained Personnel. Unauthorized repairs
performed on this equipment may result in danger to the technician and machine operator and will
invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all
safety notes and precautions detailed throughout this manual.
__________________________________________________________________________
WARNING
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Century INVERTER ARC 230 Manuel utilisateur

Catégorie
Système de soudage
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues