Chief FMSCM Guide d'installation

Catégorie
Accessoires pour projecteurs
Taper
Guide d'installation

Ce manuel convient également à

INSTALLATION INSTRUCTIONS
FMSCM
FMSCA
Fusion Modular Ceiling Heads
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
FMSCM / FMSCA
FMSCM / FMSCA Installation Instructions
2
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively “Milestone”), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.
DEFINITIONS
MOUNTING SYSTEM: A MOUNTING SYSTEM is the
primary Chief product to which an accessory and/or component
is attached.
ACCESSORY: AN ACCESSORY is the secondary Chief
product which is attached to a primary Chief product, and may
have a component attached or setting on it.
COMPONENT: A COMPONENT is an audiovisual item
designed to be attached or resting on an accessory or mounting
system such as a video camera, CPU, screen, display,
projector, etc.
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all mounting systems /
accessories are properly assembled and installed using the
instructions provided.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components attached to mounting system does not
exceed the weight capacity listed in the Fusion Modular
Systems installation instructions.
IMPORTANT ! : These installation instructions must be
used in conjunction with the Fusion Modular Systems
installation instructions.
--SAVE THESE INSTRUCTIONS--
Installation Instructions FMSCM / FMSCA
3
DIMENSIONS
7.69
195.3
8.21
208.6
0.59
15.1
3.25
82.6
3.25
82.6
1.53
38.9
C/L OF
COLUMN 4.25
108.0
4.50
114.3
7.00
177.8
2.72
69.1
2.00
50.8
TOTAL HEIGHT
ADJUST
3.84
97.6
6.96
176.7
1.53
38.9
HEIGHT ADJUST
SCREW
5.38
136.5
1.00
25.4
5.00
127.0
1.53
38.9
2.50
63.5
2.50
63.5
1.34
34.1
2.84
72.3
0.55
14.1
EXTRUSION SOLD
SEPARATELY
DIMENSIONS: INCHES
[MILLIMETERS]
FMSCM
7.85
199.5
7.69
195.3
3.25
82.6
3.25
82.6
0.59
15.1
4.50
114.3
7.00
177.8
2.72
69.1
1.53
38.9
C/L OF
COLUMN
4.25
108.0
3.84
97.6
2.00
50.8
TOTAL HEIGHT
ADJUST
6.96
176.7
1.53
38.9
FLOATING HEIGHT ADJUST
ADJUSTMENT SCREW
5.38
136.5
1.00
25.4 2.84
72.3
1.34
34.1
5.00
127.0 2.50
63.5
2.50
63.5
0.55
14.1
EXTRUSION SOLD
SEPARATELY
FMSCA
DIMENSIONS: INCHES
[MILLIMETERS]
FMSCM / FMSCA Installation Instructions
4
LEGEND
Tighten Fastener
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Phillips Screwdriver
Destornillador Phillips
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Open-Ended Wrench
Llave de boca
Gabelschlüssel
Chave de bocas
Chiave a punte aperte
Steeksleutel
Clé à fourche
By Hand
A mano
Von Hand
Com a mão
A mano
Met de hand
À la main
Hex-Head Wrench
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Zeskantsleutel
Clé à tête hexagonale
Pencil Mark
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Potloodmerkteken
Marquage au crayon
Drill Hole
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Percez un trou
Adjust
Ajustar
Einstellen
Ajustar
Regolare
Afstellen
Ajuster
Remove
Quitar
Entfernen
Remover
Rimuovere
Verwijderen
Retirez
Optional
Opcional
Optional
Opcional
Opzionale
Optie
En option
Security Wrench
Llave de seguridad
Sicherheitsschlüssel
Chave de segurança
Chiave di sicurezza
Veiligheidssleutel
Clé de sécurité
Installation Instructions FMSCM / FMSCA
5
TOOLS REQUIRED FOR INSTALLATION
PARTS
1/2" (12.7mm)
5/32" - included
3/32" - included
3/16" - included
1/2" (12.7mm)
A (2)
5/16-18 x 2"
B (2)
[Friction washer] C (2)
5/16" D (4)
5/16-18 x 1/2"
E (2)
5/16-18 x 3/4" F (1)
5/32" G (1)
3/32" H (1)
3/16"
J (1)
10-24 x 1/4"
Menu Board Ceiling Head Hardware Kit
K (1)
[Ceiling head -
height-adjust] L (1)
[Ceiling head -
floating]
M (1)
(FMSCM only)
[Bottom coupling]
(FMSCA only)
N (1)
[Hook plate] P (1)
[Back cover]
FMSCM / FMSCA Installation Instructions
6
INSTALLATION
NOTE: The following procedure assumes that Chief UL Listed
CPA or CMA ceiling plates (not included) and
extension columns (not included) have been properly
installed following instructions provided with ceiling
plates and extension columns.
The ceiling plates and columns should be installed
approximately spaced at center of outside
screens, and spacings should not exceed those
outlined in the Fusion Modular Systems
installation instructions.
IMPORTANT ! : The weight of the system should be
evenly distributed across ceiling plates.
IMPORTANT ! : Also be sure to reference ceiling system
attachment guidelines in the Fusion Modular Systems
installation instructions.
NOTE: Proceed to Attaching Ceiling Head to NPT Column
section or Attaching Ceiling Head to CPA Column
section, as appropriate.
Attaching Ceiling Head to 1-1/2" NPT Column
1. Slide ceiling head (K or L) up from below onto installed
column (not included). (See Figure 1)
2. Thread bottom coupling (M) onto installed column until tight,
with a minimum of four threads engaged. (See Figure 1)
3. Install and tighten one 10-24 x 1/4" set screw (J) into bottom
coupling (M). (See Figure 1)
Figure 1
4. Tighten two 5/16" x 3/4" set screws (E) against column.
(See Figure 2)
Figure 2
Attaching Ceiling Head to CPA Column
1. Slide ceiling head (K or L) up from below onto installed
column (not included). (See Figure 3)
2. Line up holes in sides of ceiling head (K or L) with holes in
column.
Figure 3
3. Install two 5/16" x 2" self-tapping screws (A) through two 5/16"
lock washers (C), two friction washers (B), sides of ceiling
head (K or L), and into installed column. (See Figure 3)
3
(J)
(K or L)
(M)
2
1
4
(K or L)
(E) x 2
1
(K or L)
3
(A) x 2
(B) x 2
Installation Instructions FMSCM / FMSCA
7
4. Install and tighten two 5/16" set screws (E) against column.
(See Figure 4)
Figure 4
Attaching Mounting Rail to Ceiling Head
IMPORTANT ! : Use the FMSCM height-adjust ceiling head
(K) on the outside of the mounting rails, or FMSCA floating
ceiling head (L) at the center of the mounting rails.
NOTE: Attach one end cap to one end of mounting rail
following instructions included with the FMSECAP.
1. Slide the hook plate (N) into mounting rail. (See Figure 5)
Figure 5
2. Lift the mounting rail with the hook plate up to the ceiling
head (K or L). (See Figure 6)
3. Attach hook plate (N) with mounting rail to ceiling head (K
or L) using four 5/16 x 1/2" button head cap screws (D).
(See Figure 6)
Figure 6
Adjust and Level Mounting Rail via Ceiling Head
1. Adjust the height of the ceiling head, as necessary, to level
the mounting rail across the columns. (See Figure 7)
Tighten the ceiling head height-adjust screw on the
FMSCM to raise the mounting rail.
Loosen the ceiling head height-adjust screw on the
FMSCM to lower the mounting rail.
2. Tighten the adjustment screw at the bottom of the FMSCA
ceiling head to hold the FMSCA (center) ceiling head at the
same level as the FMSCM (outer) ceiling heads.
Figure 7
3. Add back cover (P) to ceiling head (K or L). (See Figure 7)
4. Attach remaining end cap to end of mounting rail following
instructions included with the FMSECAP.
4
(E) x 2
(K or L)
(N)
Front of
mounting
rail
1
2
(N)
3
(D) x 4
(Column
not shown)
Height-adjust
screw
FMSCM
FMSCA
ceiling head
ceiling head
(side view)
1
2
Adjustment
screw
3
(P)
Installation Instructions
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P800.582.6480 / 952.225.6000
F877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P+31 (0) 495 580 852
F+31 (0) 495 580 845
Asia Pacific A Office No. 918 on 9/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P852 2145 4099
F852 2145 4477
Chief, a products division of
Milestone AV Technologies
8800-002849 Rev00
2016 Milestone AV Technologies
www.milestone.com
06/16
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Chief FMSCM Guide d'installation

Catégorie
Accessoires pour projecteurs
Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues