WAC Lighting S2SA Mode d'emploi

Catégorie
Projecteurs
Taper
Mode d'emploi
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2024
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters, East Manufacturing Facility
44 Harbor Park Drive
Port Washington, NY 11050
South East Manufacturing Facility
1600 Distribution Ct
Lithia Springs, GA 30122
Central Manufacturing Facility
1700 South J Elmer Freeway, Ste 100
Cedar Hill, TX 75104
West Manufacturing Facility
1750 S Archibald Ave
Ontario, CA 91761
1
INSTALLATION INSTRUCTIONS
WAC-STRUT - Silo
S2SA-2
OVERALL FIXTURE DIMENSIONS
SPECIFICATIONS
Input: 48VDC
Installation: WAC-STRUT System
Dimming: Via WAC-STRUT Connected Power Unit.
Refer to CPU Specications.
FIXTURE OVERVIEW
WAC-STRUT Silo is intended for use on WAC Lighting’s WAC-STRUT
Channel systems.
LED LUMINAIRE
WAC-STRUT SYSTEM
S2SA-2 48VDC WAC-STRUT System
CAUTION: TO PREVENT ELECTRICAL SHOCK, ENSURE ELECTRICITY HAS BEEN TURNED OFF AT THE CIRCUIT BREAKER
BEFORE BEGINNING.
-Read all instructions before installing.
-System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
-When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
-Retain installation instructions for future maintenance reference.
-WAC-STRUT xtures and channels feature separate data and power conductor systems. During installation and use, do not short the data or
power conductors together by any means or damage may occur.
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by WAC Lighting. Substitution of parts or accessories not designated for use with this product by WAC Lighting
could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any parts are
damaged or missing.
MISE EN GARDE: POUR ÉVITER TOUT CHOC ÉLECTRIQUE, ASSUREZVOUS QUE LE DISJONCTEUR SOIT MIS HORS TENSION AVANT DE
COMMENCER.
-Lisez toutes les instructions avant l’installation.
-Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également
aux règlements locaux.
-Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement avec
les pièces et/ou accessoires fournis pour être utilisés avec les produits WAC Lighting. Remplacer des pièces ou accessoires non conçus pour ce
produit WAC Lighting pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la garantie. Veuillez
contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
84"
12"
6"
1w"
6"
2s"
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2024
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters, East Manufacturing Facility
44 Harbor Park Drive
Port Washington, NY 11050
South East Manufacturing Facility
1600 Distribution Ct
Lithia Springs, GA 30122
Central Manufacturing Facility
1700 South J Elmer Freeway, Ste 100
Cedar Hill, TX 75104
West Manufacturing Facility
1750 S Archibald Ave
Ontario, CA 91761
2
FIG. 1
FIG. 2
INSTALLATION INSTRUCTIONS
WAC-STRUT - Silo
S2SA-2
FIG. 3
PREPARATION:
1. Shut o the power at the circuit breaker and ensure adequate room to install the new xture on the WAC-STRUT Channel system.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any parts necessary for installation.
FIXTURE INSTALLATION TO WAC-STRUT SYSTEM:
The xture features a WAC-STRUT adapter for power and mechanical
connection to the installed WAC-STRUT channel system.
1. This xture may be installed into horizontally or vertically
mounted WAC-STRUT channel systems. (See FIG. 1).
2. Fixtures are polarity agnostic, and may be installed in WAC-
STRUT channel in either orientation. (See FIG. 2).
3. Insert the xture into the channel slot. Ensure the xture is
parallel to the channel during installation. Push the xture into
the channel
until fully secured. NOTE: Fixture adapters also feature magnets
to aid in xture locating. (See FIG. 3).
CAUTION: Prior to installation in channel, clear any debris from
channel bus bar and xture, particularly on magnetic surfaces.
Any conductive elements have potential to cause electrical
shorting resulting in damage.
4. Review connection, be sure both set of locking tabs are secured
in channel prior to nishing installation.
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2024
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters, East Manufacturing Facility
44 Harbor Park Drive
Port Washington, NY 11050
South East Manufacturing Facility
1600 Distribution Ct
Lithia Springs, GA 30122
Central Manufacturing Facility
1700 South J Elmer Freeway, Ste 100
Cedar Hill, TX 75104
West Manufacturing Facility
1750 S Archibald Ave
Ontario, CA 91761
3
FIG. 4
FIG. 6
FIG. 5
INSTALLATION INSTRUCTIONS
WAC-STRUT - Silo
S2SA-2
RELOCATING THE FIXTURE IN CHANNEL:
While installed to the WAC-STRUT system, the xture may be relocated.
1. By hand, relocate the xture within a channel by pushing the adapter in the desired direction. (See FIG. 4).
2. Fixtures cannot be relocated between channels. It must be removed, repositioned, and then installed from one channel to another.
(See FIG. 5).
REMOVING THE FIXTURE FROM THE CHANNEL:
1. By hand, engage and press push button on the adapter. With push button pressed, pull the xture away from the channel,
until it is clear of the channel (See FIG. 6).
NOTE: Ensure the adapter is parallel to the channel during removal. (See FIG. 7).
2. To enable xture removal from channel, maintain free channel space of 1.5” on each side of adapter to enable access to releasing locking tabs.
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2024
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters, East Manufacturing Facility
44 Harbor Park Drive
Port Washington, NY 11050
South East Manufacturing Facility
1600 Distribution Ct
Lithia Springs, GA 30122
Central Manufacturing Facility
1700 South J Elmer Freeway, Ste 100
Cedar Hill, TX 75104
West Manufacturing Facility
1750 S Archibald Ave
Ontario, CA 91761
4
FIG. 7
FIG. 8
FIXTURE AIMING AND ADJUSTMENT:
1. Rotate the luminaires body horizontally or vertically to aim it properly. The xture can rotate +90° vertically and 360° horizontally.
(See FIG. 8)
INSTALLATION INSTRUCTIONS
WAC-STRUT - Silo
S2SA-2
90°
from
vertical
360°
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2024
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters, East Manufacturing Facility
44 Harbor Park Drive
Port Washington, NY 11050
South East Manufacturing Facility
1600 Distribution Ct
Lithia Springs, GA 30122
Central Manufacturing Facility
1700 South J Elmer Freeway, Ste 100
Cedar Hill, TX 75104
West Manufacturing Facility
1750 S Archibald Ave
Ontario, CA 91761
5
FIG. 9
FIG. 10 FIG. 12
FIG. 13
INSTALLATION INSTRUCTIONS
WAC-STRUT - Silo
S2SA-2
ACCESSORIES:
1. Fixture accommodates one lens and one glare control accessory.
Glare control accessories install into front cap use the clips
around the front cap to fasten them directly. Lens accessories
installed behind the front cap. Refer to spec sheet for list of
compatible accessories. (See FIG. 9)
2. To install lens accessories, it is necessary to remove the front cap.
With xture powered o and front cap facing toward you, rotate
the front cap clockwise just passed the position you feel a click”
3. Gently, while holding xture body secure, rock front cap
assembly back and forth while pulling it away from xture body
to remove front cap assembly (See FIG. 10)
4. Install glass lens on to clips on back side of front cap. (See FIG. 11)
5. Realign cap appropriately and reinstall. Be sure to rotate cap past
lock position to conrm secure. (See FIG. 12)
Glass Lens Accessory
FRONT CAP
LENS-16-SNOOT
LENS-16-HCM
LENS-16P-CRL
FIG. 11
360Ā
0-90Ā
TIR LENS-SPOT
-NARROW
-FLOOD
FRONT CAP
FIXED BEAM TYPE
OR
OR
OR
1
2
3
OR
Press
Press
Press
Press
N
S
SN
Press
Press
Press
FIG. 1
FIG. 2
FIG. 3
FIG. 4
FIG. 5
FIG. 6
FIG. 7
FIG. 8
FIG. 9
FIG. 11,12,13
Pending. use this as place holder
for now
FIG. 10
1
2
FIG. 11
FIG. 12
1
2
1
2
360Ā
0-90Ā
TIR LENS-SPOT
-NARROW
-FLOOD
FRONT CAP
FIXED BEAM TYPE
OR
OR
OR
1
2
3
OR
Press
Press
Press
Press
N
S
SN
Press
Press
Press
FIG. 1
FIG. 2
FIG. 3
FIG. 4
FIG. 5
FIG. 6
FIG. 7
FIG. 8
FIG. 9
FIG. 11,12,13
Pending. use this as place holder
for now
FIG. 10
1
2
FIG. 11
FIG. 12
1
2
1
2
Align body tabs
REPLACEABLE OPTIC: (For N, F, W beams. S (spot beam) features a
dedicated optic and is not interchangable.
1. Follow Accessories” steps 1 and 2 to remove front cap.
2. Rotate the lens optic counter clockwise to remove. (See FIG. 13)
3. Reverse process to reinstall lens. Ensure to align lens base with
LED holder when reassembling to conrm secure.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

WAC Lighting S2SA Mode d'emploi

Catégorie
Projecteurs
Taper
Mode d'emploi

dans d''autres langues