27
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
1.16E
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleon replaces.com [email protected]
SAFETY INFORMATION
!WARNING
If the information in these instructions
are not followed exactly, a re may result
causing property damage, personal injury
or loss of life.
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
$10.00
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA C22.2 No-46 / UL 1278
NEFL32FH, NEFL42FH, NEFL50FH,
NEFL60FH, NEFL72FH, NEFL100FH
ELECTRIC FIREPLACE
EN
W415-1542 / A / 10.06.15
2
TABLE OF CONTENTS
1.0 INTRODUCTION 3
1.1 DIMENSIONS 4
1.2 LISTING APPROVALS 4
1.3 GENERAL INSTRUCTIONS 5
1.4 UNPACKING AND TESTING APPLIANCE 5
1.5 HARDWARE PARTS LIST 6
1.6 RATING PLATE INFORMATION 7
2.0 LOCATING APPLIANCE 8
2.1 GROUNDING APPLIANCE 8
3.0 INSTALLATION 9
3.1 MINIMUM CLEARANCE TO COMBUSTIBLES 9
3.2 MINIMUM MANTEL CLEARANCES 9
3.3 INSTALLING THE APPLIANCE ONTO THE WALL 10
3.3.1 MINIMUM CLEARANCE TO COMBUSTIBLES 11
3.3.2 FRAMING 11
3.4 RECESSING THE APPLIANCE INTO THE WALL 12
3.4.1 INSTALLING THE APPLIANCE INTO A MANTEL 13
3.4.2 RUBBER FEET INSTALLATION 14
3.5 HARD WIRING INSTALLATION 15
4.0 FINISHING 16
4.1 FRONT GLASS INSTALLATION 16
4.2 FRONT GLASS REMOVAL 17
4.3 CRYSTAL EMBER INSTALLATION 17
5.0 OPERATING INSTRUCTIONS 18
5.1 MAIN POWER BUTTON 18
5.2 OPERATING TOUCH DISPLAY PANEL AND REMOTE CONTROL 18
6.0 MAINTENANCE 19
6.1 REMOTE BATTERY INSTALLATION 19
7.0 WIRING DIAGRAM 20
8.0 REPLACEMENT PARTS 22
9.0 TROUBLESHOOTING 23
10.0 WARRANTY 24
11.0 NOTES 25
EN
W415-1542 / A / 10.06.15
3
1.0 INTRODUCTION !
WARNING
3.7C
THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF
CONTACTED.
Do not operate appliance before reading and understanding operating instructions. Failure to operate
appliance according to operating instructions could cause re or injury.
Risk of burns. Power to the appliance should be turned off and the appliance allowed to cool before
servicing. To disconnect power to the appliance, turn controls to off, then remove plug from outlet.
Do not install damaged, incomplete or substitute components.
Do not burn wood or other materials in this appliance.
Young children should be carefully supervised when they are in the same room as the appliance.
Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier
is recommended if there are at risk individuals in the house. To restrict access to an appliance or stove,
install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the
room and away from hot surfaces.
Clothing or other ammable material should not be placed on or near the appliance.
Due to high temperatures, the appliance should be located out of traf c and away from furniture and
draperies.
Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot
surfaces.
Even after the appliance is out, the glass and/or screen will remain hot for an extended period of time.
Check with your local hearth specialty dealer for safety screens and hearth guards to protect children
from hot surfaces. These screens and guards must be fastened to the oor.
Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.
It is imperative that the control compartments, circulating blower and its passageway in the appliance
and are kept clean. The appliance should be inspected before use and at least annually by a quali ed
service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding
material, etc. The appliance area must be kept clear and free from combustible materials, gasoline and
other ammable vapors and liquids.
Under no circumstances should this appliance be modi ed.
Do not use this appliance if any part has been under water. Immediately call a quali ed service technician
to inspect the appliance and to replace any part of the control system which has been under water.
Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the
glass should be done by a licensed or quali ed service person.
Do not strike or slam shut the appliance glass door.
Keep the packaging material out of reach of children and dispose of the material in a safe manner. As
with all plastic bags, these are not toys and should be kept away from children and infants.
Servicing should be done only while the appliance is disconnected from the power supply circuit.
Always unplug appliance when not in use.
Do not operate this appliance with a damaged cord or plug after the appliance malfunctions, has been
dropped or damaged in any manner. Return appliance to authorized service facility for examination,
electrical or mechanical adjustment, or repair.
Do not use outdoors.
Never locate appliance where it may fall into a bathtub or other water container.
Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or the like. Arrange cord
away from traf c area and where it will not be tripped over.
Connect to properly grounded outlets only.
Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an
electric shock or re, or damage the appliance.
To prevent a possible re, do not block air intakes or exhaust in any manner. Do not use on soft
surfaces, like a carpet, where openings may become blocked.
Always plug appliances directly into a wall outlet/receptacle. Never use an extension cord or
relocatable power tap (outlet/power strip).
Ensure clearances to combustibles are maintained when building a mantel or shelves above the
appliance. Elevated temperatures on the wall or in the air above the appliance can cause melting,
discolouration or damage to decorations, a T.V. or other electronic components.
EN
W415-1542 / A / 10.06.15
4
1.1 DIMENSIONS
1.2 LISTING APPROVALS
This appliance has been tested in accordance with the CSA Standards for xed and location-dedicated electric
room appliances in the United States and Canada. If you need assistance during installation, please contact
your local dealer.
NOTE: This appliance must be electrically wired and grounded in accordance with local codes or,
in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition in the United
States or the Canadian Electric Code, CSA C22.1 in Canada.
Description Electric Fireplace
Type 3 Way Mounting Unit
Wall-Mount, Recess into Wall and
Assemble with mantel
Voltage 120V AC
Watts MAX 1500W
Amps 15 AMP Grounded Circuit
MODEL NO. NET WEIGHT GROSS WEIGHT
NEFL32FH 34.6 lbs (15.7kg) 48 lbs (21.8kg)
NEFL42FH 45.2 lbs (20.5kg) 60 lbs (27.3kg)
NEFL50FH 50.9 lbs (23.1kg) 69.4 lbs (31.5kg)
NEFL60FH 61.3 lbs (27.8kg) 82.4 (37.4kg)
NEFL72FH 87.3 (39.6kg) 115.7 (52.5kg)
NEFL100FH 118.6 (53.8kg) 156.5 (71kg)
A
B
G
F
E
D
C
DIMENSIONS
MODEL NUMBER A B C D E F G
NEFL32FH 32"
(813mm) 21 5/8"
(550mm) 5"
(127mm) 20 1/2"
(520mm) 27 5/16"
(694mm) 12"
(304mm) 22 5/16"
(567mm)
NEFL42FH 42"
(1067mm) 21 5/8"
(550mm) 5"
(127mm) 20 1/2"
(520mm) 37 1/2"
(951mm) 12"
(304mm) 32 5/16"
(821mm)
NEFL50FH 50"
(1270mm) 21 5/8"
(550mm) 5"
(127mm) 20 1/2"
(520mm) 45 7/16"
(1154mm) 12"
(304mm) 40 5/16"
(1024mm)
NEFL60FH 60"
(1524mm) 21 5/8"
(550mm) 5"
(127mm) 20 1/2"
(520mm) 55 5/16"
(1405mm) 12"
(304mm)) 50 5/16"
(1278mm)
NEFL72FH 72"
(1830mm) 21 5/8"
(550mm) 5"
(127mm) 20 1/2"
(520mm) 67 3/8"
(1711mm) 12"
(304mm) 62 5/8"
(1583mm)
NEFL100FH 100"
(2540mm) 21 5/8"
(550mm) 5"
(127mm) 20 1/2"
(520mm) 95 3/8"
(2422mm) 12"
(304mm) 90 9/16"
(2300mm)
EN
W415-1542 / A / 10.06.15
5
1.3 GENERAL INSTRUCTIONS
4.8B
A. Prior to plugging your appliance into an electrical outlet, verify that the house circuit breakers for the
outlet are on.
B. The appliance may emit a slight, harmless odour when rst used. This odour is normal and it is caused
by the initial heating of internal appliance elements and will not occur again.
C. If your appliance does not emit heat, consult the operation section of this manual for further
information.
D. Use with a CSA- or UL-certi ed surge protector.
E. Do not route the power cord directly underneath the appliance.
This electric appliance meets the construction and safety standards of H.U.D. for application in manufactured
homes when installed according to these instructions.
!
WARNING
READ THESE INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION. FAILURE TO
FOLLOW THEM COULD CAUSE AN APPLIANCE MALFUNCTION RESULTING IN SERIOUS INJURY
AND/OR PROPERTY DAMAGE.
ALL ELECTRIC APPLIANCES HAVE HOT AND ARCING OR SPARKING PARTS INSIDE. DO NOT USE
IT IN AREAS WHERE GASOLINE, PAINT OR FLAMMABLE LIQUIDS ARE PRESENT.
THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE OPTIONAL
ACCESSORIES LISTED IN THESE INSTRUCTIONS. USE OF OPTIONAL ACCESSORIES NOT
SPECIFICALLY TESTED FOR THIS ELECTRIC APPLIANCE COULD VOID THE WARRANTY AND/OR
RESULT IN A SAFETY HAZARD.
DO NOT OPEN. RISK OF ELECTRIC SHOCK. NO USER-SERVICEABLE PARTS INSIDE.
DO NOT USE DAMAGED ELECTRICAL CORDS.
SERVICING SHOULD BE DONE ONLY WHILE THE APPLIANCE IS DISCONNECTED FROM THE
POWER SUPPLY CIRCUIT.
TO PREVENT ELECTRIC SHOCK MATCH THE WIDE BLADE OF PLUG TO WIDE SLOT OF
RECEPTACLE AND FULLY INSERT.
As with most electronic devices, your new electric replace has been designed to operate at
temperatures between 5°C (41°F) and 35° C (95°F). During the colder winter months, allow the replace
to reach room temperature before turning it on.
1.4 UNPACKING AND TESTING APPLIANCE
Carefully remove the appliance from the box. Prior to installing the appliance, test to make sure the appliance
operates properly by plugging the power supply cord into a conveniently located 120 Volt, 15 Amp grounded
outlet.
NOTE: The NEFL50/60/72/100FH appliances are shipped with the front glass not assembled onto the
appliance. Refer to the "FRONT GLASS INSTALLATION" sections for assembly.
EN
W415-1542 / A / 10.06.15
6
1.5 HARDWARE PARTS LIST
A - Fireplace
NEFL32FH-100FH ( 1 )
B - Wood Screws
NEFL32FH-50FH ( 6 )
NEFL60FH-72FH (12)
NEFL100FH (16)
C - Drywall Anchors
NEFL32FH-50FH ( 6 )
NEFL60FH-72FH (12)
NEFL100FH (16)
D - ST4x12 Metal Screws
NEFL32FH-100FH ( 8 ) E - Remote Control
NEFL32FH-100FH ( 1 )
F - Wall Bracket
NEFL32FH-50FH ( 1 )
NEFL60FH-100FH ( 2 )
G-Crystals
NEFL32FH-100FH ( 2 ) H-CoverPlate
NEFL32FH-100FH ( 1 ) I - Strain Relief
NEFL32FH-100FH ( 1 )
J - Metal Bracket
NEFL32FH-100FH ( 4 ) K - Cord Corner
NEFL32FH-100FH ( 2 ) L - Cord Corner
NEFL32FH-100FH ( 2 )
M - Cord Cover
NEFL32FH ( 2 )
NEFL42FH-100FH ( 1 )
N - Rubber Foot
NEFL32FH-50FH ( 4 )
NEFL60FH-100FH ( 6 )
EN
W415-1542 / A / 10.06.15
7
1.6 RATING PLATE INFORMATION
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model of the appliance.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate
information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
W385-2095
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARD: CSA 22.2 NO. 46 AND UL 2021 / HOMOLOGUÉ SELON
LES NORMES NATIONALES CANADIENNES ET AMÉRICAINES:CSA 22.2 NO. 46 UL 2021
FOYER À ÉLECTRIQUE. HOMOLOGUE POUR
INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE
SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR
INSTALLATION DANS UNE MAISON MOBILE.
ELECTRIC FIREPLACE. SUITABLE FOR BEDROOM
AND BED-SITTING ROOM INSTALLATION. SUITABLE
FOR MOBILE HOME INSTALLATION.
VOLTAGE: 120 VAC TENSION: 120VCA
FREQUENCY: 60Hz FRÉQUENCE: 60Hz
POWER: 1500W PUISSANCE: 1500W
DATE CODE: XXXXX CODE DE DATE:
DESIGNED IN NORTH AMERCIA
BY WOLF STEEL LTD.
MADE IN CHINA FABRIQUE EN CHINE
WOLF STEEL LTD.
24 NAPOLEON ROAD,
BARRIE, ON, L4M 0G8 CANADA
SERIAL NUMBER/NO. DE SERIE: NEFL
MODELS / MODÈLES
CEFL32FH
DESIGN AMERIQUE DE NORD
PAR WOLF STEEL LTD.
MASTER CONTRACT: 161746 CONTRAT-CADRE: 161746
NEFL32FH
NEFL42FH CEFL42FH
NEFL50FH CEFL50FH
CEFL60FH
NEFL60FH
NEFL72FH CEFL72FH
NEFL100FH CEFL100FH
SAMPLE
A 22.2 NO. 46 AND UL 202
.2 NO. 46 AND UL 202
RICAINES:CSA 22.2 NO. 46CSA 22.2 NO. 46
FOYER À ÉLECTRIQUEECTRIQU
INSTALLATION DANINSTALLATION DAN
SALLE DE BAIN ESALLE DE BAIN
INSTALLATIONINSTALLATIO
VOLTAGE:OLTAGE:
12
VA
FREQUENCY
:EQUENCY:
60Hz 60H
P
OWER
:OWER:
150 150
D
ATE CODE:
DATE CODE:
SIGNED IN NORTH AMNED IN NORTH A
BY WOLF SBY WOLF S
MA
D.D.
ROAD,
OAD
L4M 0G8 CANADA
M 0G8 CANADA
SAMPLE
P
P
PL
P
P
P
P
P
P
P
P
P
P
MODELS / MODÈLES MODELS / MODÈLE
CONTRAONTRA
M
H
50FH0FH
P
EN
W415-1542 / A / 10.06.15
8
!
WARNING
2.0 LOCATING APPLIANCE
2.1 GROUNDING APPLIANCE
DUE TO HIGH TEMPERATURES, THIS ELECTRIC APPLIANCE SHOULD BE LOCATED OUT OF
TRAFFIC. KEEP COMBUSTIBLE MATERIALS SUCH AS FURNITURE, PILLOWS, BEDDING, PAPERS,
CLOTHES AND CURTAINS AT LEAST 36" FROM THE FRONT OF THE APPLIANCE.
NEVER LOCATE THIS ELECTRIC APPLIANCE WHERE IT MAY FALL INTO A BATHTUB OR OTHER
WATER CONTAINER.
WEAR SAFETY GLOVES AND SAFETY GLASSES FOR PROTECTION DURING INSTALLATION AND
MAINTENANCE.
TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION, THE ELECTRIC APPLIANCE
MUST NOT BE INSTALLED AGAINST VAPOR BARRIER OR EXPOSED INSULATION. LOCALIZED
OVERHEATING COULD OCCUR AND A FIRE COULD RESULT.
DO NOT EXPOSE THE ELECTRIC APPLIANCE TO THE ELEMENTS (SUCH AS RAIN, ETC.)
96.1
GROUNDING METHODS
METAL SCREW
(A)
NOT ALLOWED IN CANADA
GROUNDING
MEANS
ADAPTER
GROUNDING PIN
COVER OF
GROUNDED
OUTLET BOX
(C)
(B)
This appliance is for use on 120 volts. The cord has a plug
as shown in (A). An adapter as shown in (C) is available
for connecting three-blade grounding type plugs to two-slot
receptacles. The green grounding lug extending from the
adapter must be connected to a permanent ground such as
a properly grounded outlet box. The adapter should not be
used if a three-slot grounded receptacle is available.
To disconnect appliance, turn controls to off, then remove
plug from outlet.
EN
W415-1542 / A / 10.06.15
9
3.0 INSTALLATION
Your appliance is a wall-mounted, recessed and/or mantel installed appliance. Select a suitable location that is
not susceptible to moisture and is away from drapes, furniture and high traf c areas.
NOTE: Follow all National and local electrical codes.
!
WARNING
RISK OF FIRE! THE POWER CORD MUST NOT BE PINCHED AGAINST A SHARP EDGE. SECURE CORD TO AVOID
TRIPPING OR SNAGGING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY. DO NOT RUN
CORD UNDER CARPETING. DO NOT COVER CORD WITH THROW RUGS, RUNNERS OR THE LIKE. ARRANGE CORD
AWAY FROM TRAFFIC AREAS AND WHERE IT WILL NOT BE TRIPPED OVER.
RISK OF FIRE! TO PREVENT A POSSIBLE FIRE, DO NOT BLOCK AIR INTAKE OR EXHAUST IN ANY MANNER. DO NOT
USE ON SOFT SURFACES WHERE OPENINGS MAY BECOME BLOCKED.
RISK OF FIRE! DO NOT BLOW OR PLACE INSULATION AGAINST THE APPLIANCE.
THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE APPROVED OPTIONAL ACCESSORIES.
USE OF OPTIONAL ACCESSORIES NOT SPECIFICALLY TESTED FOR THIS ELECTRIC APPLIANCE COULD VOID THE
WARRANTY AND/OR RESULT IN A SAFETY HAZARD.
IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
THIS APPLIANCE IS HEAVY. IT IS HIGHLY RECOMMENDED THAT TWO PEOPLE INSTALL THIS APPLIANCE.
HEATER VENTS ON THE ELECTRIC APPLIANCE CANNOT, IN ANY WAY, BE COVERED AS IT MAY CREATE A FIRE
HAZARD.
DO NOT RUN THE POWER CORD HORIZONTALLY, DIRECTLY BELOW THE APPLIANCE.
68.5A
3.1 MINIMUM CLEARANCE TO COMBUSTIBLES
Measurements are taken from the glass front.
Bottom 0" Top 8" (203mm) to mantel
Sides 0" Top 8" (203mm) to ceiling
Back 0"
SIDE VIEW
8" (203mm)
MANTEL
FLOOR
WALL
!
WARNING
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
HEAT RESISTANT TO PREVENT DISCOLOURATION.
3.2 MINIMUM MANTEL CLEARANCES
EN
W415-1542 / A / 10.06.15
10
Due to the many different materials used on different walls, it is highly
recommended that you consult your local builder before you install this
appliance on the wall.
A. Select a location that is not prone to moisture and is located at least
36" (914mm) away from combustible materials such as curtain
drapes, furniture, bedding, paper, etc.
B. Have two people hold the appliance against the wall to determine the
nal location.
C. Place unit face down on a soft, non abbrasive surface. Remove the
bracket from the back of the unit by removing the screws, refer to
Figure 1.
D. Mark out location, then mount the bracket(s) onto the wall using the supplied screws. This bracket
MUST have the hooks facing upward and be level. NOTE: It is strongly recommended that the
mounting bracket be screwed
into the wall studs where
possible. If the wall studs
cannot be used, ensure that
the supplied plastic anchors
are used to af x the bracket
to the wall and the bracket is
adequately secured.
E. With the wall mounting bracket installed have two people lift the appliance up and insert the two hooks
on the bracket into the two slots on the back of the appliance.
F. Check the appliance for stability ensuring that the bracket will not pull free from the wall.
3.3 INSTALLING THE APPLIANCE ONTO THE WALL
HOOK
SCREWS
HOOK
SIDE VIEW
BODY
FLOOR
GLASS FRONT
21 5/8"
550mm
NEFL32/42/50FH BRACKET ILLUSTRATED
NEFL60/72/100FH BRACKET ILLUSTRATED
Measurements are taken from the body.
Sides, back and top 0"
5"
127mm
3 1/2"
89mm
MIN MAX
JUNCTION
A
B
A
B
Finishing Material
3.3.1 MINIMUM CLEARANCE TO COMBUSTIBLES
3.3.2 FRAMING
(NON-LOAD
BEARING)
EN
W415-1542 / A / 10.06.15
11
MODEL NO. A B
NEFL32FH 21" (535mm) 27 13/16" (707mm)
NEFL42FH 21" (535mm) 38" (965mm)
NEFL50FH 21" (535mm) 45 15/16" (1166mm)
NEFL60FH 21" (535mm) 55 13/16" (1418mm)
NEFL72FH 21" (535mm) 67 7/8" (1725mm)
NEFL100FH 21" (535mm) 95 7/8" (2435mm)
Due to the many different nish materials used on walls, it is highly recommended that you consult your local
builder before you install this appliance in the wall.
Select a location that is not prone to moisture and is located at least 36" (914mm) away from combustible
materials such as curtain drapes, furniture, bedding, paper etc.
3.4 RECESSING THE APPLIANCE INTO THE WALL
A. Measure the appliance and create a rough in with electrical.
B. Remove the front glass, refer to "FRONT GLASS REMOVAL" section.
C. Hold the appliance up to ensure it will t into the framing.
D. If the appliance is fully recessed into the wall:
Bend the two top tabs upward on the front glass, Figure 4.
Use the 6 screws (provided) to lock the appliance into the wall with the existing two side
anges, see Figure 2.
Install the media and reinstall the glass front.
E. If partial recess into the wall:
Use the two mounting brackets (supplied) to lock the appliance to the wall, see Figure 3.
NOTE: Two sets of holes are provided for recessing into wall. The wall structure may
limit how far the appliance can be recessed. Use the appropriate set of holes when
recessing to the frame, it may be necessary to use the four holes on the top and
bottom.
NOTE: It is recommended the walls of the appliance enclosure be nished (ie. drywall) to avoid
exposed insulation or vapour barrier coming in contact with the appliance. This will ensure clearance
to combustibles is maintained.
EN
W415-1542 / A / 10.06.15
12
NOTE: The appliance tabs come bent. You must bend the tab at by hand when fully recessing the
appliance into the wall, Figure 4.
FIG. 4
3.4.1 INSTALLING THE APPLIANCE INTO A MANTEL
A. Remove the glass front, refer to "FRONT GLASS REMOVAL " section for removal instructions.
B. Install the rubber feet onto the bottom of the appliance for stability, refer to "RUBBER FEET
INSTALLATION" section for instructions.
C. Install the top and bottom brackets provided.
D. Insert the appliance into the mantel and secure it with the brackets or refer to "ELECTRIC
FIREPLACE MANTEL" installation manual for proper appliance installation instructions.
E. Place the crystal embers along the media tray, refer to "CRYSTAL EMBER INSTALLATION" section.
F. Reinstall the glass front.
EN
W415-1542 / A / 10.06.15
13
3.4.2 RUBBER FEET INSTALLATION
A. Place the appliance face down on a soft surface.
B. Using a screw driver, remove the screws on the bottom of the appliance.
C. Install the 4 rubber feet (6 rubber feet for NEFL60/72/100FH) onto the bottom of the appliance using
the screws from Step B, see below.
NOTE: The screws for installing the rubber feet are secured to the appliance. Removal of the screws is
necessary for installing the rubber feet.
NEFL32/42/50FH ILLUSTRATED
NEFL60/72/100FH ILLUSTRATED
EN
W415-1542 / A / 10.06.15
14
3.5 HARD WIRING INSTALLATION
HARD WIRING CONNECTION
If it is necessary to hard wire this appliance, a quali ed electrician must remove the cord connection, and wire
the appliance directly to the house hold wiring.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In
the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the
current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
!
WARNING
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE
PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
A. Remove the cover plate from the right side
bottom of the appliance by removing the three
screws, as shown above.
B. Remove the wire connectors from the power
cord. The power cord may be discarded.
C. Take the new cover plate, supplied in the hardware bag. Punch out the 7/8" (22.2mm) hole and install
a box connector through, into the junction box. Snap the box connector clamp onto the supply wires.
D. Using the wire connectors, connect the ground green wires (G), the common white wires (N)
together, then the hot black wires (L) and then the refer to Figure 3.
E. Reinstall the cover plate using the three screws, as shown in Figure 1.
Fig. 1 Fig. 2
COVER PLATE
G
NL
Fig. 3
EN
W415-1542 / A / 10.06.15
15
EN
W415-1542 / A / 10.06.15
16
4.0 FINISHING !
WARNING
POWER SUPPLY SERVICE MUST BE COMPLETED PRIOR TO FINISHING TO AVOID
RECONSTRUCTION.
HEAT VENTS AND AIR OPENINGS CANNOT BE COVERED IN ANY CIRCUMSTANCES.
4.1 FRONT GLASS INSTALLATION
!
WARNING
BEFORE THE FRONT GLASS IS INSTALLED OR REMOVED UNPLUG THE APPLIANCE AND WAIT
UNTIL APPLIANCE IS COOL TO THE TOUCH. GLASS CAN BE HEAVY AND FRAGILE SO HANDLE
WITH CARE. 75.1
FOR MODELS NEFL50/60/72/100FH ONLY:
A. Before installing the front glass, remove the screws securing the paper board on the inside of the
appliance that protects the control panel. Discard the paper board.
B. Reinstall the screws,see Figure 1. (For recessed installed appliances only)
C. Remove the 2 screws from the top of the appliance.
D. Have two people, lift the glass up and away from the appliance, holding the glass vertical not at while
carrying. Place the glass face down onto a soft, non-abrasive surface, careful not to ex the glass.
E. Bend the top tabs at, see Figure 2
F. Install the crystal embers, refer to "CRYSTAL EMBER INSTALLATION" section.
G. Install the front glass by aligning with the pins on the appliance. Press the glass in and down to
securely engage with the brackets. It must be fully engaged to ensure the touch display panel
performs properly.
H. Secure the front glass using the screws provided to the top of the appliance, see Figure 3.(If fully
recessed this is not necessary)
Paper Paper
Pin
FIG. 1
FIG. 2
EN
W415-1542 / A / 10.06.15
17
FIG. 3
The glass front must be removed and the appliance must be secured in its nal location before the crystal
embers are installed.
A. Carefully place crystal embers into the bottom media tray on the
front of the appliance as illustrated. Apply an even layer from side to
side.
A. Remove the 2 screws from the top of the appliance, as shown below.
B. Have two people, lift the glass up and away from the appliance, holding the glass vertical not at while
carrying. Place the glass face down onto a soft, non-abrasive surface, careful not to ex the glass.
C. Install the crystal embers, refer to "CRYSTAL EMBER INSTALLATION" section. Install the front glass
by aligning with the pins on the appliance. This ensures the touch display panel performs properly.
FOR WALL MOUNT, PARTIAL RECESS AND MANTEL INSTALLED APPLIANCE ONLY:
4.2 FRONT GLASS REMOVAL
4.3 CRYSTAL EMBER INSTALLATION
EN
W415-1542 / A / 10.06.15
18
5.0 OPERATING INSTRUCTIONS
Once the appliance has been plugged into a grounded electrical outlet, it is ready to operate.
NOTE: Ensure the house circuit breakers for the power supply are turned on. In the event of a power
failure, the appliance will lose its memory function and will reset to factory mode when the power
returns.
The Main Power button is located on the front bottom right side of the appliance.
5.1 MAIN POWER BUTTON
5.2 OPERATING TOUCH DISPLAY PANEL AND REMOTE CONTROL
POWER Turns the appliance ON/OFF.
FLAME - ORANGE
FLAME - BLUE
TIMER
TEMPERATURE
Controls Orange Flame brightness.
6 Settings: ( F5-F4-F3-F2-F1-F0 ) Flame dims from F5 to F1.
F5 is the brightest setting and F0 is off.
Controls Blue Flame brightness.
6 Settings: ( F5-F4-F3-F2-F1-F0 ) Flame dims from F5 to F1.
F5 is the brightest setting and F0 is off..
Controls the Timer.
9 Settings: (0.5h, 1h, 2h, 3h, 4h, 5h, 6h, 7h, 8h) Press button
until reach desired setting.
HEATER Controls the Heater.
Press button to initiate the heater.
(H0) no heater or blower.
(BL) blower only.
(H1), heater blows warm air (750W)
(H2), heater blows hot air (1500W)
NOTE: Heater functions cycle from H0-BL-H1-H2, Press
and hold the heater button for 5s, the heater and
temperature setting will be locked onto the selected
setting. Hold the button for 5s again, the heater will be
unlocked.
Press and hold the button for 5 seconds. This will change the
display, from °C to °F or vice versa.
11 Settings: (64°F, 66°F, 68°F, 70°F, 72°F, 74°F, 76°F, 78°F,
80°F, 82°F and OFF) / (17°C, 19°C, 20°C, 21°C, 22°C, 23°C,
24°C, 26°C, 27°C, 28°C and OFF)
!
WARNING
WHILE THE APPLIANCE IS OPERATING DO NOT REMOVE THE GLASS PANEL. THIS WILL CAUSE
THE REMOTE CONTROL AND TOUCH PANEL TO DISFUNCTION.
The touch display panel is shown by LED's on the front bottom right of the appliance. The LED's will
disappear after 10 seconds of no function change. The Main Power button will be dim.
WARNING: Do not move or remove the glass panel, when the appliance is plugged in and operating.
This will cause the remote control and touch panel to no longer function.
EN
W415-1542 / A / 10.06.15
19
6.0 MAINTENANCE
!
WARNING
PREPARATION FOR MAINTENANCE
ALWAYS DISCONNECT THE POWER AND ALLOW THE ELECTRIC APPLIANCE TO COOL BEFORE
PERFORMING ANY CLEANING, MAINTENANCE OR RELOCATION OF THIS ELECTRIC APPLIANCE.
TURN CONTROLS TO OFF AND REMOVE PLUG FROM OUTLET OR TURN OFF THE HOUSE
CIRCUIT BREAKER TO ELECTRIC APPLIANCE RECEPTACLE.
DO NOT INSTALL REPLACEMENT LAMPS THAT EXCEED SPECIFIED MAXIMUM WATTS.
THE HALOGEN LAMPS IN YOUR APPLIANCE CAN BECOME EXTREMELY HOT. ALLOW AT LEAST
10 MINUTES BETWEEN TURNING OFF THE APPLIANCE AND REMOVING THE LAMPS TO AVOID
ACCIDENTAL BURNS.
DO NOT HANDLE THE LAMP WITH BARE FINGERS, OILS FROM YOUR SKIN WILL DAMAGE THE
LAMPS WHEY THEY HEAT UP. USE GLOVES OR A CLEAN DRY CLOTH WHEN HANDLING LAMPS.
6.1 REMOTE BATTERY INSTALLATION
1. To replace the existing battery remove the
battery holder.
2. To remove the battery holder turn remote onto
rear side and press the left side leaver towards
the center while pulling the battery holder out
using the slot provided.
3. Replace existing battery, type CR 2025, with a
new battery and reinstall the battery holder into
the remote by sliding it into position, as shown.
REMOTE
(REAR SIDE)
BATTERY HOLDER
BATTERY (CR 2025)
NOTE: The remote control must remain within 5 meters or 17 feet of the appliance to be effective, this
range may be reduced when battery power is depleted.
NOTE: The remote control has a removable plastic tab to prolong the battery life while shipping,
remove the tab for the remote control to function.
EN
W415-1542 / A / 10.06.15
20
7.0 WIRING DIAGRAM
!
WARNING
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE
PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

NAPOLEON Allure NEFL60FH Installation And Operating Instructions Manual

Catégorie
Cheminées
Taper
Installation And Operating Instructions Manual

dans d''autres langues