Chief CMA101W Le manuel du propriétaire

Taper
Le manuel du propriétaire

Ce manuel convient également à

INSTALLATION INSTRUCTIONS
Ceiling Plate
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
CMA101
CMA101 Installation Instructions
2
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.
IMPORTANT SAFETY INSTRUCTIONS!
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installers responsibility to make sure all components are
properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installers responsibility to make sure the combined weight of
all components attached to the CMA101 mount does not
exceed 500 lbs (226.8 kg).
NOTE: The weight capacity of the CMA101 mount may be
LIMITED to the lowest weight capacity of any other
component located within the mounting system.
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Do not use this product outdoors.
WARNING: Do NOT attach to vertical mounting surfaces
such as walls or angled ceilings!
IMPORTANT ! : The CMA101 mount is designed to be:
mounted to double 2" x 4" wood stud cross bracing
between two 2" x 4" ceiling joists using 5/16" x 3-1/2"
Grade 2 lag bolts (not included); or
mounted to a concrete ceiling with a minimum
thickness of 8" and a maximum drywall covering of
5/8" using 5/16" x 3-1/2" Grade 2 lag bolts (not
included) with UX10 OR AF8 anchors (not included); or
suspended from four 5/16-18 Grade ASTM A307 or
better threaded rods (not included) which are secured
to Unistrut®
(with a maximum span of 48")
by 5/16"
Grade 2 or better nuts (not included).
Threaded rods
must have 18 threads per square inch.
--SAVE THESE INSTRUCTIONS--
Installation Instructions CMA101
3
TOOLS REQUIRED FOR INSTALLATION
PARTS
DIMENSIONS
5/32" (security-included)
Hardware required - not included
(dependent on installation method)
1. Install to wood ceiling joists
5/16" x 3-1/2" (minimum length) Grade 2 lag bolts (Qty. 4)
2. Install to concrete
5/16" x 3-1/2" (minimum length) Grade 2 lag bolts (Qty. 4)
Fischer UX10 concrete anchors OR Toggler AF8 concrete anchors (Qty. 4)
3. Install to Unistrut
5/16-18 threaded rod (Qty. 4)
5/16" Grade 2 nuts (Qty. 8)
5/16" Grade 2 washers (Qty. 8)
5/32"
7/32" (wood)
5/16" (AF8)
3/8" (UX10)
A (1)
[CMA101]
B (1)
5/16-18 x 3/8"
C (1)
5/16-18 x 5/16"
D (1)
5/32" (security)
(security)
.69
17.463
1 1/2" NPS
2.00
50.800
127
5.00
127
5.00
101.600
4.00
4.00
101.600
4X 9.931
.39
2.00
50.800
DIMENSIONS: [MILLIMETERS]
INCHES
CMA101 Installation Instructions
4
LEGEND
Tighten Fastener
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Phillips Screwdriver
Destornillador Phillips
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Open-Ended Wrench
Llave de boca
Gabelschlüssel
Chave de bocas
Chiave a punte aperte
Steeksleutel
Clé à fourche
By Hand
A mano
Von Hand
Com a mão
A mano
Met de hand
À la main
Hex-Head Wrench
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Zeskantsleutel
Clé à tête hexagonale
Pencil Mark
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Potloodmerkteken
Marquage au crayon
Drill Hole
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Percez un trou
Adjust
Ajustar
Einstellen
Ajustar
Regolare
Afstellen
Ajuster
Remove
Quitar
Entfernen
Remover
Rimuovere
Verwijderen
Retirez
Optional
Opcional
Optional
Opcional
Opzionale
Optie
En option
Security Wrench
Llave de seguridad
Sicherheitsschlüssel
Chave de segurança
Chiave di sicurezza
Veiligheidssleutel
Clé de sécuri
Installation Instructions CMA101
5
INSTALLATION
WARNING: Do NOT attach to vertical mounting surfaces
such as walls or angled ceilings!
WARNING: IMPROPER INSTALLATION CAN LEAD TO
MOUNT FALLING CAUSING SEVERE PERSONAL INJURY
OR DAMAGE TO EQUIPMENT! It is the installer’s
responsibility to make certain the structure to which the
mount is being attached is capable of supporting five times
the weight of the CMA mount and all attached equipment.
Reinforce the structure as required before installing the
mount.
NOTE: The following instructions assume a suitable mounting
structure and surface exists prior to installation.
NOTE: Proceed to Wood Stud Installation section, Solid
Concrete Installation section, or Threaded Rod
Installation section.
Wood Stud Installation
1. Carefully determine required mounting location.
IMPORTANT ! : This will require knowing the lens to
screen distance. See projector specifications for details
on determining this distance.
WARNING: IMPROPER INSTALLATION CAN RESULT IN
SERIOUS PERSONAL INJURY OR DAMAGE TO
EQUIPMENT! Structural members MUST be capable of
supporting five times the combined weight of all equipment
being mounted.
IMPORTANT ! : The CMA101 is designed to be mounted to
double 2" x 4" wood stud cross bracing (4" on center) between
two ceiling joists with a maximum drywall covering of 5/8".
2. Using the CMA101 as a guide, mark four mounting hole
locations. Hole locations must be centered on 2" x 4" cross
braces. (See Figure 1)
3. Drill four 7/32" diameter x 2-1/2" long pilot holes. (See
Figure 1)
Figure 1
4. Align four mounting holes in CMA101 with four pilot holes.
(See Figure 2)
5. Secure CMA101 to structure using four 5/16" x 3-1/2" Grade
2 lag bolts (not included). (See Figure 2)
Figure 2
23
x 4
x 4
5
CMA101 Installation Instructions
6
Solid Concrete Installation
1. Determine mounting location.
IMPORTANT ! : This will require knowing the lens to
screen distance. See projector specifications for details
on determining this distance.
WARNING: The CMA101 is designed to be mounted to a
concrete ceiling with a minimum thickness of 8" and a
maximum drywall covering of 5/8".
WARNING: IMPROPER INSTALLATION CAN RESULT IN
SERIOUS PERSONAL INJURY OR DAMAGE TO
EQUIPMENT! Structural members MUST be capable of
supporting five times the combined weight of all equipment
being mounted.
2. Using the CMA101 as a guide, mark four mounting hole
locations on ceiling. (See Figure 3)
3. Drill four 3-1/4" deep pilot holes. (See Figure 3)
For Fischer UX10 anchors, use a 3/8" drill bit.
For Toggler AF8 anchors, use a 5/16" drill bit.
4. Align four mounting holes in CMA101 with four pilot holes.
Figure 3
WARNING: Anchors (not provided) must be installed into
structurally sound solid concrete. Installation into hollow
concrete block, mortar, or concrete that exhibits cracking,
spalling, or other defects may result in failure of anchor and
serious personal injury or damage to equipment.
5. Install four Fischer UX10 or Toggler AF8 concrete anchors
(not included) until flush with mounting surface. (See
Figure 4)
6. Secure CMA101 to structure using four 5/16" x 3-1/2" Grade
2 lag bolts (not included). (See Figure 4)
Figure 4
3
x 4
2
x 4
6
5
x (4)
Installation Instructions CMA101
7
Threaded Rod Installation
IMPORTANT ! : The CMA101 ceiling plate may be
installed via threaded rods to 1-5/8” wide Unistrut ceiling
channels spanning a maximum distance of 48". The total
combined weight of all components attached to the
CMA101 MUST NOT exceed the allowable load of the
channel!
NOTE: The CMA101 may be
suspended from four 5/16-18
Grade ASTM A307 or better threaded rods (not
included) which are secured to Unistrut by 5/16" Grade
2 or better nuts (not included).
Threaded rods must
have 18 threads per square inch.
1. Secure one end of each of the four threaded rods (not
included) to the structural member.
2. Install one 5/16" nut (not included) and one 5/16" washer
(not included) onto each threaded rod.
3. Install CMA101 onto threaded rods, inserting the rods into
the four holes on top of the CMA101.
4. Secure the threaded rods to the CMA101 with one 5/16" nut
(not included) and one 5/16" washer (not included) on each
threaded rod. (See Figure 5)
Figure 5
Attaching Column to CMA101
1. Install 1-1/2" NPT or NPSM following ANSI/ASME B1.20.1
(Schedule 40, 0.154" minimum thickness steel or aluminum
- ASTM B221) threaded extension column (not included)
into threaded collar of CMA101 until tight, with a minimum
of four threads engaged. (See Figure 6)
2. Install 5/16-18 x 3/8" set screw (B) [OPTIONAL: Use one
5/16-18 x 5/16" security set screw (C) for security
installation] into hole on ceiling plate (A) to secure pipe to
mount. (See Figure 6)
Figure 6
3
1
Secure to Unistrut
using nuts
3
4
Secure with
nuts and washers
(not included)
(not included).
Threaded
rods
(A)
(B)
1-1/2" NPT threaded
2
(A)
column (not included)
(C)
1
OR
CMA101 Installation Instructions
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P800.582.6480 / 952.225.6000
F877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P+31 (0) 495 580 852
F+31 (0) 495 580 845
Asia Pacific A Office No. 1 on 12/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P852 2145 4099
F852 2145 4477
Chief, a products division of
Milestone AV Technologies
8800-002519 Rev00
2014 Milestone AV Technologies
www.chiefmfg.com
03/14
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Chief CMA101W Le manuel du propriétaire

Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues