Dell PowerEdge T310 Guide de démarrage rapide

Catégorie
Les serveurs
Taper
Guide de démarrage rapide
Dell™ PowerEdge™
T310 Systems
Getting Started
With Your System
Začínáme se systémem
Guide de mise en route
Erste Schritte mit dem System
Τα πρώτα βήµατα µε το σύστηµά σας
Rozpoczęcie pracy z systemem
Начало работы с системой
Procedimientos iniciales con el sistema
תכרעמה םע הדובעה תליחת
Dell™ PowerEdge™
T310 Systems
Getting Started
With Your System
Regulatory Model E09S
Regulatory Type E09S001
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use
of your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data
if instructions are not followed.
WARNING: A WARNING indicates a potential for property damage, personal
injury, or death.
____________________
Information in this document is subject to change without notice.
© 2009 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, and PowerEdge are trademarks of Dell Inc.;
Intel and Xeon are registered trademarks of Intel Corporation in the U. S. and other countries;
Microsoft, Windows, Windows Server, and Hyper-V are either trademarks or registered trademarks
of Microsoft Corporation in the United States and/or other countries; Red Hat and Enterprise Linux
are registered trademarks of Red Hat, Inc. in the United States and other countries; SUSE is a registered
trademark of Novell, Inc. in the United States and other countries.
Other trademarks and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
Regulatory Model E09S
Regulatory Type E09S001
May 2009 P/N H655K Rev. A00
Getting Started With Your System 3
Installation and Configuration
WARNING: Before performing the following procedure, review the safety
instructions that came with the system.
Optional – Connecting the Keyboard, Mouse, and Monitor
Connect the keyboard, mouse, and monitor (optional).
The connectors on the back of your system have icons indicating which cable
to plug into each connector. Be sure to tighten the screws (if any) on the
monitor's cable connector.
4 Getting Started With Your System
Connecting the Power Cable(s)
Connect the system’s power cable(s) to the system and, if a monitor is used,
connect the monitor’s power cable to the monitor.
Securing the Power Cable(s)
Bend the system power cable(s) into a loop as shown in the illustration and
secure the cable(s) with the provided strap.
Plug the other end of the power cable(s) into a grounded electrical outlet
or a separate power source such as an uninterrupted power supply (UPS)
or a power distribution unit (PDU).
Getting Started With Your System 5
Turning On the System
Press the power button on the system and the optional monitor, if used.
The power indicators should light.
Complete the Operating System Setup
If you purchased a preinstalled operating system, see the operating system
documentation that ships with your system. To install an operating system for
the first time, see the installation and configuration documentation for your
operating system. Be sure the operating system is installed before installing
hardware or software not purchased with the system.
Supported Operating Systems
Microsoft
®
Windows
®
Server 2008 R2 Standard and Enterprise (x64)
Editions
Microsoft Windows Server
®
2008 Standard and Enterprise (x86)
Editions with SP2
Microsoft Windows Server 2008 Standard and Enterprise (x64) Editions
Microsoft Windows Server 2008 Standard and Enterprise (x86) Editions
Microsoft Windows Small Business Server 2008 Standard and
Premium (x64) Editions
6 Getting Started With Your System
Microsoft Windows Essential Business Server 2008 Standard and
Premium (x64) Editions
Microsoft Windows Server 2003 R2 Standard and Enterprise (x64)
Editions with SP2
Microsoft Windows Server 2003 R2 Standard and Enterprise (x86)
Editions with SP2
•Red Hat
®
Enterprise Linux
®
ES (Version 5.3) (x86)
Red Hat Enterprise Linux ES (Version 5.3) (x86_64)
•SUSE
®
Linux Enterprise Server 11 (x86_64)
Microsoft Windows Server 2008 Hyper-V™
NOTE: For the latest information on supported operating systems,
see www.dell.com.
Other Information You May Need
WARNING: See the safety and regulatory information that shipped with your
system. Warranty information may be included within this document or as a
separate document.
•The
Hardware Owner’s Manual
provides information about system
features and describes how to troubleshoot the system and install or
replace system components. This document is available online at
support.dell.com
.
Any media that ships with your system that provides documentation and
tools for configuring and managing your system, including those
pertaining to the operating system, system management software, system
updates, and system components that you purchased with your system.
NOTE: Always check for updates on support.dell.com and read the updates
first because they often supersede information in other documents.
Getting Started With Your System 7
Obtaining Technical Assistance
If you do not understand a procedure in this guide or if the system
does not perform as expected, see your Hardware Owner’s Manual.
Dell™ offers comprehensive hardware training and certification. See
www.dell.com/training for more information. This service may not be
offered in all locations.
Technical Specifications
Processor
Processor type One quad-core Intel
®
Xeon
®
processor
Expansion Bus
Bus type PCI Express Generation 2
Expansion slots Slot1: PCIe x8 (x8 routing) half-length
Slot2: PCIe x16 (x8 routing) full-length
Slot3: PCIe x8 (x4 routing) half-length
Slot4: PCIe x1 (x1 routing) half-length
Slot5: PCIe x1 (x1 routing) half-length
Memory
Architecture 800-MHz, 1066-MHz, or 1333-MHz DDR3
registered or unbuffered Error Correcting
Code (ECC) DIMMs.
Memory module sockets Six 240-pin
Memory module capacities 1 GB, 2 GB, 4 GB, or 8 GB
Minimum RAM 1 GB
Maximum RAM 32 GB
8 Getting Started With Your System
Drives
Hard drives Up to four 3.5-inch hot-plug SAS or
SATA internal drives
or
Up to four 3.5-inch cabled SAS or
SATA internal drives
or
Up to four 2.5-inch hot-plug SAS or
SSD internal drives in a 3.5-inch carrier.
Optical drive Optional internal SATA DVD-ROM or
DVD+/-RW
Optional external USB DVD-ROM
NOTE: DVD devices are data only.
Tape drive One optional internal half height tape
backup device
Connectors
Back
NIC
Two RJ-45 (for integrated 1-GB NICs)
Serial
9-pin, DTE, 16550-compatible
USB
Four 4-pin, USB 2.0-compliant
Video
15-pin VGA
Front
USB
Two 4-pin, USB 2.0-compliant
Internal
USB
Two 4-pin, USB 2.0-compliant
Video
Video type Matrox G200, integrated in iDRAC
Video memory 8 MB
Getting Started With Your System 9
Power
AC power supply (per power supply)
Wattage
375 W (non-redundant power supply)
400 W (redundant power supply)
Voltage
100-240 VAC, 50/60 Hz, 5.8A-2.9A
Heat dissipation
1683 BTU/hr maximum (non-redundant
power supply)
1672 BTU/hr maximum (redundant power
supply)
Maximum inrush current
Under typical line conditions and over
the entire system ambient operating range,
the inrush current may reach 25A (redundant
power supply) and 35A (non-redundant
power supply) per power supply for 10 ms
or less.
Batteries
System battery
CR 2032 3.0-V lithium ion coin cell
Physical
Height 44 cm (17.3 inch)
Width 21.8 cm (8.6 inch)
Depth 52.1 cm (20.5 inch)
Weight (maximum configuration) 23.5 kg (51.8 lb)
10 Getting Started With Your System
Environmental
NOTE: For additional information about environmental measurements for specific
system configurations, see www.dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE: For altitudes above 2950 feet,
the maximum operating temperature is
derated 1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with a
maximum temperature gradation of 20°C
per hour
Relative humidity
Operating
20% to 80% (noncondensing) with a
maximum humidity gradation of 10%
per hour
Storage
20% to 85% (noncondensing)
Maximum vibration
Operating
0.26 G at 5–500 Hz for 15 min
Storage
1.54 G at 10–250 Hz for 15 min
Maximum shock
Operating
One shock pulse in the positive z axis
(one pulse on each side of the system) of
31 G for 2.6 ms in the operational orientation
Storage
Six consecutively executed shock pulses in
the positive and negative x, y, and z axes
(one pulse on each side of the system) of
71 G for up to 2 ms
Getting Started With Your System 11
Altitude
Operating
0 to 3,048 m (0 to 10,000 ft)
NOTE: For altitudes above 2950 feet,
the maximum operating temperature is
derated 1ºF/550 ft.
Storage
0 to 10,605 m (–50 to 35,000 ft)
Airborne Contaminant Level
Class
G2 or lower as defined by ISA-S71.04-1985
Environmental (continued)
12 Getting Started With Your System
Dell™ PowerEdge™
Systémy T310
Začínáme se
systémem
Regulační model E09S
Regulační typ E09S001
Poznámky a upozornění
POZNÁMKA: POZNÁMKA označuje důležité informace, které pomáhají
lepšímu využití počítače.
UPOZORNĚNÍ: UPOZORNĚNÍ poukazuje na možnost poškození
hardwaru nebo ztráty dat v případě nedodržení pokynů.
VAROVÁNÍ: VAROVÁNÍ upozorňuje na potenciální nebezpečí
poškození majetku, úrazu nebo smrti.
____________________
Informace obsažené v tomto dokumentu podléhají změnám bez předchozího upozornění.
© 2009 Dell Inc. Všechna práva vyhrazena.
Jakákoli reprodukce těchto materiálů bez písemného povolení společnosti Dell Inc. je přísně zakázána.
Ochranné známky použité v tomto textu: Dell, logo DELL a PowerEdge jsou ochranné známky
společnosti Dell Inc.; Intel a Xeon jsou registrované ochranné známky společnosti Intel Corporation
v U SA a dalších zemích; Microsoft, Windows, Windows Server a Hyper-Vjsou buď ochranné známky,
nebo registrované ochranné známky společnosti Microsoft Corporation ve Spojených státech nebo v
dalších zemích; Red Hat a Enterprise Linux jsou registrované ochranné známky společnosti Red
Hat, Inc. ve Spojených státech a dalších zemích; SUSE je registrovaná ochranná známka společnosti
Novell, Inc., ve Spojených státech a dalších zemích.
V tomto dokumentu mohou být použity další ochranné známky a obchodní názvy s odkazem na
společnosti vlastnící tyto známky a názvy nebo na jejich produkty. Společnost Dell Inc. nemá
vlastnické zájmy vůči ochranným známkám a obchodním názvům jiným než svým vlastním.
Regulační model E09S
Regulační typ E09S001
Květen 2009 Č. dílu H655K Rev. A00
Začínáme se systémem 15
Instalace a konfigurace
VAROVÁNÍ: Před provedením následujícího postupu si prostudujte
bezpečnostní pokyny dodané se systémem.
Volitelné – Připojení klávesnice, myši a monitoru
Připojte klávesnici, myš a monitor (volitelné).
Konektory na zadní straně systému mají ikony znázorňující, který kabel se má
připojit ke kterému konektoru. Zajistěte, aby šrouby na konektoru kabelu monitoru
byly dobře dotaženy (je-li jimi konektor vybaven).
16 Začínáme se systémem
Připojení napájecích kabelů
Připojte napájecí kabely k systému, a pokud používáte monitor, připojte napájecí
kabel také k monitoru.
Zajištění napájecích kabelů
Ohněte napájecí kabely systému do smyčky, jak je znázorněno na obrázku,
a zajistěte je dodanou páskou.
Poté zasuňte druhý konec napájecích kabelů do uzemněné elektrické zásuvky nebo
je připojte k samostatnému zdroji napájení, například ke zdroji nepřerušitelného
napájení (UPS) nebo jednotce rozvaděče (PDU).
Začínáme se systémem 17
Zapnutí systému
Stiskněte vypínač na systému a na volitelném monitoru (pokud je používán).
Indikátory napájení by se měly rozsvítit.
Dokončení nastavení operačního systému
Pokud jste zakoupili předinstalovaný operační systém, prostudujte dokumentaci k
operačnímu systému dodanou se systémem. Chcete-li provést první instalaci
operačního systému, postupujte podle dokumentace k instalaci a konfiguraci
operačního systému. Než začnete s instalací hardwaru či softwaru, který nebyl
zakoupen společně se systémem, ujistěte se, že je nainstalován operační systém.
Podporované operační systémy
Microsoft
®
Windows
®
Server 2008 R2 Standard a Enterprise (x64)
Microsoft Windows Server
®
2008 Standard a Enterprise (x86)
s aktualizací SP2
Microsoft Windows Server 2008 Standard a Enterprise (x64)
Microsoft Windows Server 2008 Standard a Enterprise (x86)
Microsoft Windows Small Business Server 2008 verze Standard
a Premium (x64)
Microsoft Windows Essential Business Server 2008 Standard
a Premium (x64)
18 Začínáme se systémem
Microsoft Windows Server 2003 R2 Standard a Enterprise (x64)
s aktualizací SP2
Microsoft Windows Server 2003 R2 Standard a Enterprise (x86)
s aktualizací SP2
Red Hat
®
Enterprise Linux
®
ES (verze 5.3) (x86)
Red Hat Enterprise Linux ES (verze 5.3) (x86_64)
SUSE
®
Linux Enterprise Server 11 (x86_64)
Microsoft Windows Server 2008 Hyper-V™
POZNÁMKA: Nejnovější informace o podporovaných operačních
systémech naleznete na webu www.dell.com.
Další užitečné informace
VAROVÁNÍ: Prostudujte si informace o bezpečnosti a předpisech,
které byly dodány se systémem. Informace o záruce je součástí
tohoto dokumentu nebo je přiložena samostatně.
Příručka majitele hardwaru
obsahuje informace o funkcích systému a
popisuje řešení problémů se systémem a instalaci nebo výměnu komponent.
Tento dokument je k dispozici online na webu
support.dell.com.
Média dodaná se systémem obsahují dokumentaci a nástroje pro konfiguraci
a správu systému. Mohou být dodána například média týkající se operačního
systému, softwaru pro správu systému, aktualizací systému a komponent
zakoupených se systémem.
POZNÁMKA: Vždy nejprve zkontrolujte a pročtěte aktualizace
uvedené na adrese support.dell.com, protože tyto aktualizace často
nahrazují informace v ostatních dokumentech.
Odborná pomoc
Nerozumíte-li některému z postupů popsaných v této příručce nebo nepracuje-li
systém podle očekávání, nahlédněte do
Příručky majitele hardwaru
. Společnost
Dell™ nabízí v souvislosti s hardwarem kompletní školení a certifikaci. Další
informace naleznete na webových stránkách
www.dell.com/training
. Tato služba
nemusí být nabízena ve všech regionech.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105

Dell PowerEdge T310 Guide de démarrage rapide

Catégorie
Les serveurs
Taper
Guide de démarrage rapide

dans d''autres langues