Simplicity 030254-0 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON,WISCONSIN, U.S.A.
Manual No. 200309GS
Revision - (05/09/2006)
Model / Modèle / Modelo
030254
Operator’s Manual
Manuel d’utilisation
Manual del Operario
EXL8000
13500 STARTING WATTS
Questions? Help is just a moment away!
Vous avez des questions? Vous n'avez pas besoin
d'aller loin pour trouver de l'aide!
Preguntas? La ayuda es justa un momento lejos!
Call: Generator Helpline
Appelez: Ligne d'assistance de Génératrice
Llame: Línea Directa del Generador
1-800-743-4115 M-F 8-5 CT
web: www.briggsandstratton.com
Before using this product, read this
manual and follow all Safety Rules and
Operating Instructions.
WARNING
Antes de utilizar el producto, lea este
manual y siga todas las Reglas de
Seguridad e Instrucciones de Uso.
ADVERTENCIA
Avant d’utiliser ce produit, veuillez lire
le manuel et suivre toutes les directives
relatives à la sécurité et à l’utilisation.
AVERTISSEMENT
2
SAFETY RULES
TABLE OF CONTENTS
Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Features and Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-14
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-21
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Emissions Control Warranties . . . . . . . . . . . . . . . . . . . 25-27
Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28-29
Français . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-57
Español . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58-84
EQUIPMENT
DESCRIPTION
Read this manual carefully and become
familiar with your generator. Know its
applications, its limitations and any hazards
involved.
The generator is an engine–driven, revolving field,
alternating current (AC) generator. It was designed to
supply electrical power for operating compatible electrical
lighting, appliances, tools and motor loads.The generator’s
revolving field is driven at about 3,600 rpm by a single-
cylinder engine.
CAUTION! DO NOT exceed the generator’s
wattage/amperage capacity. See “Don’t Overload
Generator”.
Every effort has been made to ensure that information in
this manual is accurate and current. However, we reserve
the right to change, alter or otherwise improve the product
and this document at any time without prior notice.
The Emission Control System for this generator is
warranted for standards set by the Environmental
Protection Agency and the California Air Resources Board.
SAFETY RULES
This is the safety alert symbol. It is used to
alert you to potential personal injury hazards.
Obey all safety messages that follow this
symbol to avoid possible injury or death.
The safety alert symbol ( ) is used with a signal word
(DANGER, CAUTION,WARNING), a pictorial and/or a
safety message to alert you to hazards. DANGER indicates
a hazard which, if not avoided, will result in death or serious
injury. WARNING indicates a hazard which, if not avoided,
could result in death or serious injury. CAUTION
indicates a hazard which, if not avoided, might result in
minor or moderate injury. CAUTION, when used
without the alert symbol, indicates a situation that could
result in equipment damage. Follow safety messages to
avoid or reduce the risk of injury or death.
Hazard Symbols and Meanings
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
WARNING
Copyright © 2006 Briggs & Stratton Power Products
Group, LLC. All rights reserved. No part of this material
may be reproduced or transmitted in any form by any
means without the express written permission of Briggs &
Stratton Power Products Group, LLC.
SAVE THESE INSTRUCTIONS
Fire
Explosion
Toxic Fumes
Hot Surface
Electrical Shock
Kickback
Operator’s Manual
Hazardous Chemical
3
SAFETY RULES
This generator does not meet U. S. Coast Guard Regulation
33CFR-183 and should not be used on marine applications.
Failure to use the appropriate U. S. Coast Guard approved
generator could result in death or serious injury and/or
property damage.
WARNING
When using generator for backup power, notify utility
company. Use approved transfer equipment to isolate
generator from electric utility.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area, such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing
in water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
Generator produces powerful voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.
WARNING
Operate generator ONLY outdoors.
Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes or other openings.
DO NOT operate generator inside any building or enclosure
(even if doors or windows are open), including the generator
compartment of a recreational vehicle (RV).
Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Breathing carbon monoxide can cause nausea,
fainting or death.
WARNING
WHEN ADDING OR DRAINING FUEL
Turn generator OFF and let it cool at least 2 minutes before
removing fuel cap. Loosen cap slowly to relieve pressure in
tank.
Fill or drain fuel tank outdoors.
DO NOT overfill tank.Allow space for fuel expansion.
Wait for spilled fuel to evaporate before starting engine.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
DO NOT light a cigarette or smoke.
WHEN STARTING EQUIPMENT
Ensure spark plug, muffler, fuel cap and air cleaner are in place.
DO NOT crank engine with spark plug removed.
WHEN OPERATING EQUIPMENT
DO NOT tip engine or equipment at angle which causes fuel
to spill.
This generator is not for use in mobile equipment or marine
applications.
WHEN TRANSPORTING OR REPAIRING
EQUIPMENT
Transport/repair with fuel tank EMPTY or with fuel shutoff
valve OFF.
Disconnect spark plug wire.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL
IN TANK
Store away from furnaces, stoves, water heaters, clothes
dryers or other appliances that have pilot light or other
ignition source because they can ignite fuel vapors.
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.
WARNING
If SWALLOWED, call physician immediately.
In case of emergency, contact a physician immediately and call
1-800-424-9300 for material safety information.
**Fuel stabilizer contains: 2,6-di-tret-butylphenol (128-39-2) and
aliphatic petroleum distillate (64742-47-8).
Contents are harmful or fatal if swallowed.
Avoid contact to eyes, skin or clothing. DO
NOT take internally.Avoid breathing the mist or
vapor. Overexposure to eyes or skin can cause
irritation. Keep stabilizer out of the reach of
children.
Fuel stabilizer is a hazardous chemical.**
DANGER
SAFETY RULES
4
DO NOT tamper with governed speed. Generator supplies
correct rated frequency and voltage when running at governed
speed.
DO NOT modify generator in any way.
Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy load.
CAUTION
See “Don’t Overload Generator”.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator
before stopping generator.
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.
CAUTION
Use generator only for intended uses.
If you have questions about intended use, ask dealer or call
1-800-743-4115.
Operate generator only on level surfaces.
DO NOT expose generator to excessive moisture, dust, dirt,
or corrosive vapors.
DO NOT insert any objects through cooling slots.
If connected devices overheat, turn them off and disconnect
them from generator.
Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
Improper treatment of generator can damage it and
shorten its life.
CAUTION
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
Unintentional sparking can result in fire or
electric shock.
WARNING
DO NOT touch hot surfaces and avoid hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 ft. (152 cm) clearance on all sides of generator
including overhead.
Code of Federal Regulation (CFR) Title 36 Parks, Forests, and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.
Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING
When starting engine, pull cord slowly until resistance is felt
and then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in
and turned on.
Rapid retraction of starter cord (kickback) will
pull hand and arm toward engine faster than
you can let go.
Broken bones, fractures, bruises or sprains could
result.
WARNING
FEATURES AND CONTROLS
5
KNOW YOUR GENERATOR
Read this Operator’s Manual and safety rules before operating your generator.
Compare the illustrations with your generator to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
Choke Lever
120 Volt AC, 15 Amp
GFCI Duplex Receptacles
Run/Stop Switch
Spark Arrester
Muffler
Start Switch
Grounding
Fastener
Air Cleaner
Fuel Tank
Oil Fill Cap
Data Tag
Hour Meter
Battery Float Charger Jack
Circuit
Breakers (AC)
120/240 Volt AC, 30 Amp
Locking Receptacle
Double Pole
Circuit Breaker
120 Volt AC, 15 Amp GFCI Duplex Receptacles
May be used to supply electrical power for the operation of
120 Volt AC, 15 Amp, single phase, 60 Hz electrical lighting,
appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle — May
be used to supply electrical power for the operation of
120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz
electrical lighting, appliance, tool and motor loads.
Air Cleaner — Protects engine by filtering dust and
debris out of intake air.
Battery Float Charger Jack — Use battery float
charger to keep the starting battery charged and ready for
use.
Choke Lever — Used when starting a cold engine.
Circuit Breakers (AC) — Push to reset circuit breakers
are provided to protect the generator against electrical
overload.
Data Tag – Provides model, revision and serial number of
generator. Please have these readily available if calling for
assistance.
Double Pole Circuit Breaker (AC) — A double pole
circuit breaker is provided to protect the 30A receptacle
and generator against electrical overload.
Fuel Tank — Capacity of seven (7) U.S. gallons.
Fuel Valve — Used to turn fuel supply on and off to engine.
Grounding Fastener — Consult your local agency having
jurisdiction for grounding requirements in your area.
Hour Meter — Displays and records how many hours
your generator has run (up to 9,999.9).
Oil Fill Cap Add oil to engine here.
Recoil Starter — Used to start the engine manually.
Run/Stop Switch — Set this switch to "Run" before
starting engine. Set switch to "Stop" to switch off engine.
Spark Arrester Muffler — Exhaust muffler lowers engine
noise and is equipped with a spark arrester screen.
Start Switch — Push and hold in Start” position for a
maximum of 15 seconds during each start attempt, until
engine starts.
Recoil Starter
Fuel Valve
ASSEMBLY
6
ASSEMBLY
Your generator requires some assembly and is ready for
use after it has been properly serviced with the
recommended oil and fuel.
If you have any problems with the assembly of your
generator, please call the generator helpline at
1-800-743-4115. If calling for assistance, please have the
model, revision, and serial number from the data tag available.
See “Know Your Generator” for data tag location.
Unpacking the Generator
1. Set the carton on a rigid flat surface.
2. Open carton completely by cutting each corner from
top to bottom.
3. Cut ties holding accessory kit and extension cord to
generator and remove everything from carton.
ELECTRIC START
Your unit is equipped with electric start capability but can
be started manually. If you choose not to use the electric
start feature, you do not need to install the negative
battery cable.
Check Battery / Attach Negative
Battery Wire
The sealed battery on the generator is fully charged and
pre–installed except for the negative (black) battery cable.
You will need the following tools to install the negative
battery cable:
Socket wrench with a 8 mm socket
Diagonal cutters
To install:
1. Cut off tie wrap securing loose end of negative (black)
cable.
2. Using a 8 mm socket wrench, remove screw, lock
washer and flat washer on negative battery terminal.
3. Slide lock washer, flat washer and negative battery
cable over screw (Figure 1).
4. Reattach screw to negative battery terminal and
tighten.
5. Verify that connections to battery and generator are
tight and secure.
Figure 1 — Negative Battery Connection
Negative
Battery Cable
Screw
Flat Washer
Lock Washer
Positive
Battery Cable
7
ASSEMBLY
BEFORE STARTING THE
ENGINE
Add Engine Oil
CAUTION! Any attempt to crank or start the engine
before it has been properly serviced with the
recommended oil may result in an engine failure.
1. Place generator on a flat, level surface.
2. Clean area around oil fill and remove yellow oil fill cap.
NOTE: See the section “Oil” on page 17 to review oil
recommendations.Verify provided oil bottle is correct
viscosity for current ambient temperature.
3. Using oil funnel (optional), slowly pour contents of
both provided oil bottles into oil fill opening to the
point of overflowing.
4. Replace oil fill cap and fully tighten.
Add Fuel
NOTE: This gasoline engine is certified to operate on
gasoline. Exhaust Emission Control System: EM (Engine
Modifications).
1. Use clean, fresh, regular UNLEADED fuel with a
minimum of 85 octane. DO NOT use fuel which
contains Methanol. DO NOT mix oil with fuel.
2. Clean area around fuel fill cap, remove cap.
3. Slowly add regular unleaded fuel to fuel tank. Be careful
not to fill above the baffle.This allows adequate space
for fuel expansion (Figure 2).
4. Install fuel cap and let any spilled fuel evaporate before
starting engine.
CAUTION! Alcohol-blended fuels (called gasohol,
ethanol or methanol) can attract moisture, which leads to
separation and formation of acids during storage.Acidic gas
can damage the fuel system of an engine while in storage.
To avoid engine problems, the fuel system should be
treated with fuel preserver or emptied before storage of
30 days or longer. If adding fuel preserver, fill the fuel tank
with fresh fuel. If only partially filled, air in the tank will
promote fuel deterioration during storage. If fuel preserver
is not used, drain the fuel tank, start the engine and let it
run until the fuel lines and carburetor are empty. Use fresh
fuel next season. See “Storage” on page 22 for additional
information.
NEVER use engine or carburetor cleaner products in the
fuel tank as permanent damage may occur.
FUEL
TANK
Figure 2 — Typical Fuel Expansion Space
Baffle
WHEN ADDING FUEL
Turn generator OFF and let it cool at least 2 minutes before
removing fuel cap. Loosen cap slowly to relieve pressure in tank.
Fill fuel tank outdoors.
DO NOT overfill tank.Allow space for fuel expansion.
Wait for spilled fuel to evaporate before starting engine.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
DO NOT light a cigarette or smoke.
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.
WARNING
If SWALLOWED, call physician immediately.
In case of emergency, contact a physician immediately and call
1-800-424-9300 for material safety information.
**Fuel stabilizer contains: 2,6-di-tret-butylphenol (128-39-2) and
aliphatic petroleum distillate (64742-47-8).
Contents are harmful or fatal if swallowed.
Avoid contact to eyes, skin or clothing. DO
NOT take internally.Avoid breathing the mist or
vapor. Overexposure to eyes or skin can cause
irritation. Keep stabilizer out of the reach of
children.
Fuel stabilizer is a hazardous chemical.**
DANGER
OPERATION
8
USING THE GENERATOR
System Ground
The generator has a system ground that connects the
generator frame components to the ground terminals on
the AC output receptacles.The system ground is connected
to the AC neutral wire (the neutral is bonded to the
generator frame).
Special Requirements
There may be Federal or State Occupational Safety and
Health Administration (OSHA) regulations, local codes, or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction.
Connecting to a Building’s Electrical
System
Connections for standby power to a building’s electrical
system must be made by a qualified electrician.The
connection must isolate the generator power from utility
power, and must comply with all applicable laws and
electrical codes.
Generator Location
Generator Clearance
Place generator in a well ventilated area, which will allow
for removal of deadly exhaust gas. DO NOT place
generator where exhaust gas could accumulate and enter
inside or be drawn into a potentially occupied building.
Ensure exhaust gas is kept away from any windows, doors,
ventilation intakes or other openings that can allow exhaust
gas to collect in a confined area (Figure 3). Prevailing winds
and air currents should be taken into consideration when
positioning generator.
When using generator for backup power, notify utility
company. Use approved transfer equipment to isolate
generator from electric utility.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area, such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing
in water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
Generator produces powerful voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.
WARNING
Figure 3 — Generator Clearance
Exhaust Port
Typical Generator Shown
Operate generator ONLY outdoors.
Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes or other openings.
DO NOT operate generator inside any building or enclosure
(even if doors or windows are open), including the generator
compartment of a recreational vehicle (RV).
Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Breathing carbon monoxide can cause nausea,
fainting or death.
WARNING
Keep at least 5 ft. (152 cm) clearance on all sides of generator
including overhead.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING
9
OPERATION
OPERATING THE
GENERATOR
Starting the Engine
IMPORTANT: Always unplug the battery float charger
before starting the generator.
Disconnect all electrical loads from the generator. Use the
following start instructions:
1. Make sure unit is on a level surface.
IMPORTANT: Failure to start and operate unit on a level
surface will cause the unit not to start or shut down during
operation.
2. Turn fuel valve to On” position (Figure 4).
3. Set run/stop switch to Run” position (Figure 5).
4. Place choke lever in Full” choke position (Figure 6).
5A. For electric starting, push and hold the start switch
in start position (Figure 7) until generator starts.To
prolong the life of starter components, DO NOT hold
start switch in start position for more than
15 seconds, and pause for at least 1 minute between
starting attempts.
If engine starts, proceed to step 7.
If engine fails to start, proceed to step 6.
NOTE: If battery is discharged, use manual starting
instructions.
5B. For manual starting, grasp recoil handle and pull
slowly until slight resistance is felt.Then pull rapidly
one time only to start engine.
If engine starts, proceed to step 7.
If engine fails to start, proceed to step 6.
6. Move choke lever to Half” choke position, and pull
recoil handle twice.
If engine fails to start, repeat steps 5 thru 7.
7. Slowly move choke lever to Run” position. If engine
falters, move choke lever to Half” choke position
until engine runs smoothly, and then to Run” position.
NOTE: If engine starts after 3 pulls, but fails to run for
more than 10 seconds, check for proper oil level in
crankcase.This unit is equipped with a Low Oil Pressure
Shutdown System. See “Low Oil Pressure Shutdown
System”.
When starting engine, pull cord slowly until resistance is felt
and then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in
and turned on.
Rapid retraction of starter cord (kickback) will
pull hand and arm toward engine faster than
you can let go.
Broken bones, fractures, bruises or sprains could
result.
WARNING
Figure 4 — Fuel Shut-off Valve
Figure 7 — Start Switch
Figure 5 — Run/Stop Switch
Figure 6 — Choke Lever
OPERATION
10
Connecting Electrical Loads
Let engine stabilize and warm up for a few minutes after
starting.
Plug in and turn on the desired 120 and/or 240 Volt AC,
single phase, 60 Hz electrical loads.
DO NOT connect 240 Volt loads to the 120 Volt duplex
receptacles.
DO NOT connect 3–phase loads to the generator.
DO NOT connect 50 Hz loads to the generator.
DO NOT OVERLOAD THE GENERATOR. See
“Don’t Overload Generator”.
Stopping the Engine
1. Turn OFF and unplug all electrical loads from generator
panel receptacles. NEVER start or stop engine with
electrical devices plugged in and turned ON.
2. Let engine run at no-load for several minutes to
stabilize internal temperatures of engine and generator.
3. Move Run/Stop switch to Stop” position.
4. Move fuel valve to “Off” position.
Low Oil Pressure Shutdown System
The engine is equipped with a low oil pressure sensor that
shuts down the engine automatically when the oil pressure
drops below 8 psi. If the engine shuts down by itself and
the fuel tank has enough gasoline, check engine oil level.
Initial Start–up
A delay built into the low oil shutdown system allows oil
pressure to build during starting.The delay allows the
engine to run for about 10 seconds before sensing oil
pressure.
Sensing Low Pressure
If the system senses low oil pressure during operation, the
engine shuts down.As the system shuts down, the low oil
light comes ON. However, once the engine has stopped
rotating, this light will go OFF.
Restarting
If you try to restart the engine within 10 seconds after it
shuts down, the engine may NOT start.The system needs
5 to 10 seconds to reset.
If you do restart the engine after such a shutdown and have
not corrected the low oil pressure, the engine runs for
about 10 seconds as described above and then stops.
RECEPTACLES
A double pole rocker switch circuit breaker is provided to
protect the locking receptacle. If this circuit breaker is
tripped, all panel receptacles are disconnected.
See “Don’t Overload Generator”.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator
before stopping generator.
Exceeding generator’s wattage/amperage capacity can
damage generator and/or electrical devices connected to it.
CAUTION
DO NOT touch hot surfaces and avoid hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 ft. (152 cm) clearance on all sides of generator
including overhead.
Code of Federal Regulation (CFR) Title 36 Parks, Forests, and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.
Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING
NEVER attempt to power a device requiring more amperage
than generator or receptacle can supply.
DO NOT overload the generator. See “Don’t Overload
Generator”.
Receptacles may be marked with rating value greater
than generator output capacity.
CAUTION
OPERATION
11
120/240 Volt AC, 30 Amp, Locking
Receptacle
Use a NEMA L14–30 plug with this receptacle. Connect a
4–wire cord set rated for 250 Volt AC loads at 30 Amps (or
greater) (Figure 8).You can use the same 4–wire cord if you
plan to run a 120 Volt load.
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 7,200 watts of power (7.2 kW)
at 30 Amps for 240 Volts or two independent 120 Volt
loads at 30 Amps each.The outlet is protected by a double
pole rocker switch circuit breaker.
IMPORTANT: This generator’s locking receptacle and the
provided adapter cord set are not protected by a Ground
Fault Circuit Interrupter (GFCI). If used on an OSHA
governed job site, appropriate GFCI protection must be
utilized.
120 Volt AC, 15 Amp, GFCI Duplex
Receptacles
Each duplex receptacle (Figure 9) is protected against
overload by a push–to–reset circuit breaker.
NOTE: If the double pole circuit breaker is tripped, the
duplex receptacles are disconnected.
Use each receptacle to operate 120 Volt AC, single–phase,
60 Hz electrical loads requiring up to 1,800 watts (1.8 kW)
at 15 Amps of current. Use grounded cord sets that are
rated for 125 Volt AC loads at 15 Amps (or greater).
Inspect cord sets before each use.
Ground Fault Protection
The duplex receptacles are equipped with Ground Fault
Circuit Interrupter (GFCI) protection.This device meets
applicable federal, state and local codes.The generator’s
locking receptacle is not protected by a GFCI.
The GFCI protects against electrical shock that may be
caused if your body becomes a path in which electricity
travels to reach the ground.This could happen if you touch
a “Live” appliance or wire, or are touching plumbing or
other materials that connect to the ground.
When protected by a GFCI, one may still feel a shock, but
the GFCI should cut current off quickly enough so that a
person in normal health should not suffer any serious
electrical injury.
Figure 8 — 120/240 Volt AC, 30 Amp Receptacle
4-Wire Cord Set
240V
120V
120V
W (Neutral)
X (Hot)
Y (Hot)
NEMA L14-30
Ground (Green)
Figure 9 — 120 Volt, 15 Amp GFCI Duplex Receptacle
Contact with the hot and neutral conductor at the same time
can cause electrical shock or burn, even if the circuit is GFCI
protected.
Before using the GFCI receptacle,ALWAYS push the test
button to insure it works.
Generator produces hazardous voltage/current.
WARNING
OPERATION
12
Testing the GFCI
Test your GFCI outlet prior to each use, as follows:
Push the black Test” button.The red Reset” button
should pop out, which should allow no power to reach
the outlet. Use a test lamp in each outlet to test this.
If the GFCI tests good, restore power by pressing the
Reset” button firmly until it is fully in place and locks in that
position. If the GFCI outlet does not reset properly, do
not use the outlet. Call or take your generator to a
local service center.
If the GFCI trips by itself at any time, reset and test the
outlet. If the reset button does not pop out when
the test button is pressed, do not use the outlet.
Call or take your generator to a local service center.
GENERATOR ADAPTER
CORD SET
The generator is supplied with a 25’ generator adapter
cord set designed for a 240 Volt, 30 Amp grounded neutral
circuit (Figure 10).
The maximum load on each outlet is 15 Amps.The
maximum total load on both yellow wire outlets or black
wire outlets is 30 Amps. Each outlet is protected by a
15 Amp fuse.
IMPORTANT: This generator’s locking receptacle and the
provided adapter cord set are not protected by a Ground Fault
Circuit Interrupter (GFCI). If used on an OSHA governed job
site, appropriate GFCI protection must be utilized.
NOTE: Follow all safety precautions when connecting any
extension cord or device to the generator.
HOW TO USE THE
BATTERY CHARGER
Use battery float charger to keep the starting battery
charged and ready for use. Battery charging should be done
in a dry location, such as inside a garage.
1. Plug charger into unit’s “Battery Float Charger” jack,
which is located next to start switch (Figure 11). Plug
battery charger into a 120 Volt AC wall receptacle.
2. Unplug charger from unit and wall outlet when
generator is being started and while it is in operation.
3. Keep this charger plugged in and connected when
generator is not in use to prolong battery life.The
charger has a built in float equalizer and will not
overcharge battery, even when plugged in for an
extended period of time.
IMPORTANT: See “Battery Maintenance” on page 17 for
additional information.
Figure 10 — Generator Adapter Cord Set
Figure 11 — Battery Charger Jack
DO NOT use any outlets on the circuit.
Call or take your generator to a local service center.
The “Reset” button does not pop out or the test lamp
remains lit when the “Reset” button is popped out.
CAUTION
13
OPERATION
COLD WEATHER
OPERATION
Under certain weather conditions (temperatures below
40°F [4°C] combined with high humidity), your generator
may experience icing of the carburetor and/or the
crankcase breather system.To reduce this problem, you
need to perform the following:
1. Make sure generator has clean, fresh fuel.
2. Open fuel valve (turn valve to open position).
3. Use SAE 5W-30 oil.
4. Check oil level daily or after every eight (8) hours of
operation.
5. Maintain generator following “Maintenance Schedule”
on page 16.
6. Shelter unit from elements.
Creating a Temporary Cold Weather
Shelter
1. In an emergency, use the original shipping carton.
2. Cut off top carton flaps and one long side of carton to
expose muffler side of unit. If required, tape up other
sides of carton to fit over generator as shown in
Figure 12.
NOTE: If required, remove wheel kit to fit carton over
generator as shown in Figure 12.
3. Cut appropriate slots to access receptacles of unit.
4. Face exposed end away from wind and elements.
5. Locate generator as described in the section
“Generator Location”. Keep exhaust gas from entering
a confined area through windows, doors, ventilation
intakes or other openings.
6. Start generator as described in the section “Starting
the Engine”, then place carton over generator. Keep at
least 5 ft. (152 cm) clearance on all sides of generator
including overhead with shelter in place.
7. Remove shelter when temperatures are above 40°F
[4°C].
8. Turn engine OFF and let cool two (2) minutes before
refueling.Wipe up any spilled fuel.
Creating a Permanent Cold Weather
Shelter
1. Build a structure that will enclose three sides and the
top of the generator, making sure muffler side of
generator is exposed.
NOTE: Structure should hold enough heat created by the
generator to prevent icing problem.
2. DO NOT enclose generator any more than shown in
Figure 12.
NOTE: If a wheel kit is installed on the generator, enlarge
shelter accordingly.
3. Follow steps 3 through 8 as described previously in
“Creating a Temporary Cold Weather Shelter”.
Figure 12 — Cold Weather Shelter
Wind
Operate generator ONLY outdoors.
Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes or other openings.
DO NOT operate generator inside any building or enclosure
(even if doors or windows are open), including the generator
compartment of a recreational vehicle (RV).
Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Breathing carbon monoxide can cause nausea,
fainting or death.
WARNING
Typical Generator
Shown
DO NOT touch hot surfaces and avoid hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 ft. (152 cm) clearance on all sides of generator
including overhead.
Remove shelter when temperatures are above 40°F [4°C].
Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING
OPERATION
14
DON'T OVERLOAD
GENERATOR
Capacity
You must make sure your generator can supply enough
rated (running) and surge (starting) watts for the items you
will power at the same time. Follow these simple steps:
1. Select the items you will power at the same time.
2. Total the rated (running) watts of these items.This is
the amount of power your generator must produce to
keep your items running. See Figure 13.
3. Estimate how many surge (starting) watts you will
need. Surge wattage is the short burst of power
needed to start electric motor-driven tools or
appliances such as a circular saw or refrigerator.
Because not all motors start at the same time, total
surge watts can be estimated by adding only the
item(s) with the highest additional surge watts to the
total rated watts from step 2.
Example:
Total Rated (Running) Watts = 3075
Highest Additional Surge Watts = 1800
Total Generator Output Required = 4875
Power Management
To prolong the life of your generator and attached devices,
it is important to take care when adding electrical loads to
your generator.There should be nothing connected to the
generator outlets before starting it's engine.The correct
and safe way to manage generator power is to sequentially
add loads as follows:
1. With nothing connected to the generator, start the
engine as described in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly.
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
NEVER add more loads than the generator capacity.Take
special care to consider surge loads in generator capacity,
as described above.
*Wattages listed are approximate only. Check tool or
appliance for actual wattage.
Tool or Appliance
Rated (Running)
Watts
Additional Surge
(Starting) Watts
Window Air
Conditioner
1200 1800
Refrigerator 800 1600
Deep Freezer 500 500
Television 500 -
Light (75 Watts) 75 -
3075 Total
Running Watts
1800 Highest
Surge Watts
Tool or Appliance
Rated*
(Running)
Watts
Additional
Surge
(Starting)
Watts
Essentials
Light Bulb - 75 watt
75
-
Deep Freezer
500
500
Sump Pump
800
1200
Refrigerator/Freezer - 18 Cu. Ft.
800
1600
Water Well Pump - 1/3 HP
1000
2000
Heating/Cooling
Window AC - 10,000 BTU
1200
1800
Window Fan
300
600
Furnace Fan Blower - 1/2 HP
800
1300
Kitchen
Microwave Oven - 1000 Watt
1000
-
Coffee Maker
1500
-
Electric Stove - Single Element
1500
-
Hot Plate
2500
-
Family Room
DVD/CD Player
100
-
VCR
100
-
Stereo Receiver
450
-
Color Television - 27”
500
-
Personal Computer w/17” monitor
800
-
Other
Security System
180
-
AM/FM Clock Radio
300
-
Garage Door Opener - 1/2 HP
480
520
Electric Water Heater - 40 Gallon
4000
-
DIY/Job Site
Quartz Halogen Work Light
1000
-
Airless Sprayer - 1/3 HP
600
1200
Reciprocating Saw
960
960
Electric Drill - 1/2 HP
1000
1000
Circular Saw - 7 1/4”
1500
1500
Miter Saw - 10”
1800
1800
Table Planer - 6”
1800
1800
Table Saw/Radial Arm Saw - 10”
2000
2000
Air Compressor - 1-1/2 HP
2500
2500
Figure 13 - Wattage Reference Chart
SPECIFICATIONS
15
ENGINE TECHNICAL
INFORMATION
This is a single cylinder, overhead valve(OHV), air cooled
engine. It is a low emissions engine.
In the State of California, this type of engine is certified by
the California Air Resources Board to meet emissions
standards for 1000 hours. Such certification does not grant
the purchaser, owner or operator of this engine any
additional warranties with respect to the performance or
operational life of this engine.The engine is warranted
solely according to the product and emissions warranties
stated elsewhere in this manual.
Emissions Compliance Period
This engine is certified to meet the United States
Environmental Protection Agency (USEPA) Phase 2
emission standards. For phase 2 certified engines, the
Emissions Compliance Period referred to on the Emissions
Compliance label indicates the number of operating hours
for which the engine has been shown to meet Federal
emission requirements. For engines less than 225 cc
displacement, Category C = 125 hours, B = 250 hours and
A = 500 hours. For engines of 225 cc or more, Category C
= 250 hours, B = 500 hours and A = 1000 hours.
This engine has an Air Index of 3.The EPA Emissions
compliance period is Category A.The displacement of this
engine is 407 cc.
Power Ratings
* The power ratings for an individual engine model are
initially developed by starting with SAE (Society of
Automotive Engineers) code J1940 (Small Engine Power &
Torque Rating Procedure) (Revision 2002-05). Given both
the wide array of products on which our engines are
placed, and the variety of environmental issues applicable to
operating the equipment, it may be that the engine you
have purchased will not develop the rated horsepower
when used in a piece of power equipment (actual “on-site”
power).This difference is due to a variety of factors
including, but not limited to, the following: differences in
altitude, temperature, barometric pressure, humidity, fuel,
engine lubrication, maximum governed engine speed,
individual engine to engine variability, design of the
particular piece of power equipment, the manner in which
the engine is operated, engine run-in to reduce friction and
clean out of combustion chambers, adjustments to the
valves and carburetor, and other factors.The power ratings
may also be adjusted based on comparisons to other
similar engines utilized in similar applications, and will
therefore not necessarily match the values derived using
the foregoing codes.
PRODUCT
SPECIFICATIONS
Generator Specifications
Starting Wattage . . . . . . . . . . . . . . . . . . . . . . .13,500 Watts
Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7,200 Watts
Rated AC Load Current:
At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . . . .60.0 Amps
At 240 Volts . . . . . . . . . . . . . . . . . . . . . . . . . . .30.0 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . .240 lbs.
Engine Specifications
Gross* Horsepower . . . . . . . . . . . . . . . . . . 15 at 3600 rpm
Bore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 mm
Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 mm
Displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407 cc
Spark Plug
Type: . . . . . . . . . . . . Champion RC14YC or Equivalent
Set Gap To: . . . . . . . . . . . . . . . . . . 0.030 inch (0.76 mm)
Valve clearance with valve springs installed and piston is at
top dead center (check when engine is cold).
Intake . . . . . . . . . . . . . . . . . 0.002-0.004 in. (0.05-0.10 mm)
Exhaust . . . . . . . . . . . . . . . . 0.002-0.004 in. (0.05-0.10 mm)
Fuel Capacity . . . . . . . . . . . . . . . . . . . . . . . . . 7 U.S. gallons
Oil Capacity (with oil filter) . . . . . . . . . . . . . . . . . . 51 fl. oz.
Oil Type:
Above 40° F . . . . . . . . . . . . . . . . . . .SAE 30 or 10W-30
Below 40° F . . . . . . . . . . . . . . . .SAE 5W-30 or 10W-30
NOTE: For practical operation, the generator load should
not exceed 85% of rated wattage. Engine gross horsepower
will decrease 3-1/2% for each 1,000 feet (300 meters)
above sea level and 1% for each 10° F (5.6° C) above 77° F
(25° C).
MAINTENANCE
16
FILL IN DATES AS YOU
COMPLETE REGULAR SERVICE
SERVICE DATES
SERVICE DATES
MAINTENANCE TASK
Before
Each Use
Every 25
Hours or Yearly
Every 50
Hours or Yearly
Every 100 Hours
or 6 months
Every 100
Hours or Yearly
Check oil level
X
Clean debris
X
Clean fuel valve
X
Change engine oil and oil filter
Service foam pre-filter
X
Service air filter
Service spark plug
X
Service spark arrester
X
Adjust valve clearance
X
Prepare for storage If unit is to remain idle for longer than 30 days.
¹ Change oil after the first (8) operating hours and every 100 hours or every year, whichever occurs first, thereafter.
Change sooner when operating under dirty or dusty conditions.
² Replace more often under dirty or dusty conditions.
Figure 14 – Maintenance Schedule
GENERAL
RECOMMENDATIONS
Regular maintenance will improve the performance and
extend the life of the generator. See any authorized dealer
for service.
The generator’s warranty does not cover items that have
been subjected to operator abuse or negligence.To receive
full value from the warranty, the operator must maintain
generator as instructed in this manual.
Some adjustments will need to be made periodically to
properly maintain your generator.
All service and adjustments should be made at least once
each season. Follow the requirements in the “Maintenance
Schedule” chart below in Figure 14.
NOTE: Once a year you should clean or replace the spark
plug and replace the air filter.A new spark plug and clean
air filter assure proper fuel-air mixture and help your
engine run better and last longer.
GENERATOR
MAINTENANCE
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves, or any other foreign material.
Check the cleanliness of the generator frequently and clean
when dust, dirt, oil, moisture or other foreign substances
are visible on its exterior surface.
NOTE: DO NOT use water or other liquids to clean
generator. Liquids can enter the engine fuel system causing
poor performance and / or failure to occur. In addition, if
liquids enters the generator through cooling air slots, some
of the liquid will be retained in voids and cracks of the rotor
and stator winding insulation. Liquid and dirt buildup on the
generator internal windings will eventually decrease the
insulation resistance of these windings.
Generator Cleaning
Daily or before use, clean accumulated debris from
generator. Keep linkage, spring and controls clean. Keep area
around and behind muffler free from any combustible debris.
Generator parts should be kept clean to reduce the risk of
overheating and ignition of accumulated debris.
Use a damp cloth to wipe exterior surfaces clean.
Use a soft bristle brush to loosen caked on dirt, oil, etc.
Use a vacuum cleaner to pick up loose dirt and debris.
MAINTENANCE
17
Use low pressure air (not to exceed 25 psi) to blow
away dirt. Inspect cooling air slots and openings on the
generator.These openings must be kept clean and
unobstructed.
Battery Maintenance
Other than float charging, described elsewhere, no
maintenance is required for the starting battery. Keep the
battery and terminals clean and dry.
IMPORTANT: Battery charging should be performed in a
dry location, such as inside a garage.
Fuel Valve Maintenance
The fuel valve is equipped with a fuel sediment cup, screen,
retaining ring and o-ring that need to be cleaned every
6 months or 100 hours (whichever occurs first).
1. Move fuel valve to Off” position.
2. Remove sediment cup from fuel valve. Remove o-ring,
retaining ring and screen from fuel valve (Figure 15).
3. Wash sediment cup, o-ring, retaining ring, and screen in
a nonflammable solvent. Dry them thoroughly.
4. Place screen, retaining ring, and o-ring into fuel valve.
Install sediment cup and tighten securely.
5. Move fuel valve to On” position, and check for leaks.
Replace o-ring if there is any leakage.
ENGINE MAINTENANCE
Oil
Oil Recommendations
NOTE: When adding oil to the engine crankcase, use only
high quality detergent oil rated with API service
classification SF, SG, SH, SJ or higher. DO NOT use special
additives. DO NOT USE SAE 10W-40.
1. Choose a viscosity according to the following table:
* The use of multi-viscosity oils (5W-30, 10W-30, etc.) in
temperatures above 40°F (4°C) will result in higher than
normal oil consumption.When using a multi-viscosity oil,
check oil more frequently.
** If using SAE 30 oil in temperatures below 40°F (4°C), it
will result in hard starting and possible engine bore damage
due to inadequate lubrication.
Checking Oil Level
Oil level should be checked prior to each use or at least
every 8 hours of operation. Keep oil level maintained.
1. Make sure generator is on a level surface.
2. Remove oil fill cap and wipe clean with cloth.
3. Verify oil is at the point of overflowing at oil fill opening.
DO NOT expose generator to excessive moisture, dust, dirt,
or corrosive vapors.
DO NOT insert any objects through cooling slots.
Improper treatment of generator can damage it and
shorten its life.
CAUTION
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
Unintentional sparking can result in fire or
electric shock.
WARNING
5W-30, 10W-30
30, 10W-30
Figure 15 — Fuel Valve Maintenance
Sediment Cup
O-ring
Retaining Ring
Screen
MAINTENANCE
18
Adding Engine Oil
1. Make sure generator is on a level surface.
2. Check oil level as described in “Checking Oil Level”.
3. If needed, using oil funnel (optional), slowly pour oil
into oil fill opening to the point of overflowing at oil fill
cap.
Changing Engine Oil and Oil Filter
Change the oil and filter after the first 8 hours of
operation. Change oil and filter every 100 hours thereafter.
If you are using your generator under extremely dirty or
dusty conditions, or in extremely hot weather, change the
oil more often.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.
Change the oil and filter while the engine is still
warm from running, as follows:
1. Make sure unit is on a level surface.
2. Disconnect the spark plug wire from the spark plug
and place the wire where it cannot contact spark plug.
3. Clean area around oil drain plug.The oil drain plug is
located at base of engine, opposite carburetor.
4. Remove oil drain plug and drain oil completely into a
suitable container.
5. Reinstall oil drain plug and tighten securely.
6. Turn oil filter counterclockwise to remove and drain
oil completely into a suitable container.
7. Coat the gasket of a new oil filter with engine oil.
8. Turn the new filter clockwise until the gasket contacts
the filter adapter, then tighten an additional 3/4 turn.
9. Remove oil fill cap.
10. Using oil funnel (optional), slowly pour oil (about 51 oz.)
into oil fill opening to the point of overflowing at oil fill
cap. DO NOT overfill.
11. Reinstall oil fill cap. Finger tighten cap securely.
12. Wipe up any spilled oil.
Service Air Cleaner
Your engine will not run properly and may be damaged if
you run it using a dirty air cleaner.
Check the air cleaner every use and clean or replace the
paper air filter every 50 hours of operation or yearly,
whichever comes first. Clean or replace more often if
operating under dusty or dirty conditions. Clean or replace
the foam pre-filter every 25 hours of operation or sooner
under dusty or dirty conditions.
To clean or replace air cleaner components:
1. Loosen air cleaner cover screws and remove cover.
2. Remove foam pre-filter and paper filter from air
cleaner cover (Figure 16).
3. Wipe clean inside of air cleaner housing and cover
thoroughly.
4. To clean or replace the foam pre-filter, wash pre-filter
in a solution of household detergent and warm water,
then rinse thoroughly. Squeeze dry in a clean cloth.
5. Saturate foam pre-filter in clean engine oil and squeeze
in a clean, absorbent cloth to remove all excess oil.
DO NOT twist.
IMPORTANT: The engine will smoke during initial start-
up if too much oil is left in the pre-filter.
Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
Thoroughly wash exposed areas with soap and water.
Avoid prolonged or repeated skin contact with used
motor oil.
CAUTION
Figure 16 — Service Air Cleaner
MAINTENANCE
19
6. Clean paper filter by tapping it gently on a solid
surface. If the paper filter is too dirty, replace it with a
new one. Dispose of the old filter properly.
7. Insert the foam pre-filter into the air cleaner cover,
then the paper filter.
8. Reinstall air cleaner cover and tighten screws.
Clean/Replace Spark Plug
Check and clean the spark plug every 100 hours of
operation or yearly, whichever comes first.This will help
your engine to start easier and run better.
1. Disconnect the spark plug wire from the spark plug
and place the wire where it cannot contact spark plug.
2. Clean the area around the spark plug.
3. Remove and inspect the spark plug.
4. Replace the spark plug if electrodes are pitted or
burned or the porcelain is cracked. Use a Champion
RC14YC or equivalent plug for replacement.
5. Check electrode gap with wire feeler gauge and set
spark plug gap to 0.030 inch (0.76 mm) if necessary
(Figure 17).
6. Reinstall spark plug.
7. Reconnect spark plug wire to spark plug.
Clean Spark Arrester Screen
The engine exhaust muffler has a spark arrester screen.
Inspect and clean the screen every 100 hours of operation
or once each year, whichever comes first.
If you use your generator on any forest-covered, brush-
covered, or grass-covered unimproved land, it must have a
spark arrester.The spark arrester must be maintained in
good condition by the owner/operator.
Clean and inspect the spark arrester as follows:
1. To remove muffler heat shield from muffler, remove
four screws that connect guard to muffler bracket
(Figure 18).
2. Remove four screws that attach spark arrester screen.
3. Inspect screen and replace if torn, perforated or
otherwise damaged. DO NOT use a defective screen. If
screen is not damaged, clean it with commercial
solvent.
4. Reattach screen and muffler guard.
Figure 17 — Service Spark Plug
Muffler
Spark Arrester
Screen
Heat Shield
DO NOT touch hot surfaces and avoid hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 ft. (152 cm) clearance on all sides of generator
including overhead.
Code of Federal Regulation (CFR) Title 36 Parks, Forests, and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.
Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING
Figure 18 — Service Spark Arrester
MAINTENANCE
20
SERVICE AND
ADJUSTMENTS
Engine Speed
The engine runs at a constant speed.This constant
operating speed is maintained by a mechanical, flyweight
type, fixed speed governor. DO NOT try to adjust the
governed speed for the following reasons.
Operating the engine at high engine speeds increases the
risk of injury and damage to the equipment.
Operating the engine at low engine speeds with heavy
loads may shorten the engine’s life.
If the engine is running too fast or too slow, take it to an
authorized service center. Changing the engine’s governed
speed will void the warranty.
Carburetor Adjustments
The carburetor of the engine is pre-set at the factory. DO
NOT tamper with the carburetor or it will void the
Emissions Control System Warranty. If problems occur and
the engine is used at an altitude in excess of 5000 feet,
contact your nearest authorized service center regarding
high altitude setting changes.
Checking/Adjusting Valve Clearance
After the first 50 hours of operation, you should adjust the
valve clearance in the engine.
IMPORTANT: If you feel uncomfortable about doing this
procedure or you don’t have the proper tools, please take
your generator in to the nearest service center to have the
valve clearance adjusted.This is a very important step to
insure the longest life for your engine.
To adjust valve clearance:
1. Make sure the engine is at room temperature.
2. Make sure that spark plug wire is removed from spark
plug and out of way.
3. Remove breather tube from valve cover.
4. Remove four screws holding valve cover with a #2 or
#3 phillips screwdriver.
5. Make sure piston is at Top Dead Center (TDC) of its
compression stroke (both valves closed).To get the
piston at TDC, pull on recoil handle slowly watching
piston through spark plug hole.As you pull on recoil
handle, piston should move up and down.The piston is
at TDC when it is up as high as it can go.
DO NOT tamper with governed speed. Engine supplies
correct rated frequency and voltage when running at governed
speed.
DO NOT modify generator in any way.
Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy load.
CAUTION
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84

Simplicity 030254-0 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur