Air Pressure Regulation Unit with Shut-off Valve for Air Jet Box HERMES Q / Hermes+
Edition: 08/2019 · Part No. 9003271
Assembly Instructions
1
2 3 54
Versions
5984805 Air Pressure Regulation Unit L
with Shut-off Valve for Air Jet Box
HERMES QL, Hermes+ L
5984795 Air Pressure Regulation Unit R
with Shut-off Valve for Air Jet Box
for HERMES QR, Hermes+ R
Contents of Delivery
1 - Air Pressure Regulation Unit
2 - 4 Screws M4x10
3 - Connector
4 - 2 Screws M6x10
5 - Bracket
6 - Tube
1
2 37 8
10
9
Mounting
Attaching to the Bracket
► Attach the air pressure regulation unit (1) with 4 screws
M4x10 (2) to the connector (3).
► Insert the slot nuts (7) of the mounted unit into the slot
(10) of the bracket (9).
► Tighten the screws (8).
1
54
112 12
Attaching to the Chassis of the Printer
► Attach the air pressure regulation unit (1) with 4 screws
M4x10 (2) to the bracket (5).
► Attach the mounted unit with 2 screws M6x10 (4) to the
drillings (12) of the chassis.
If the drillings (12) are already used for the attachment of a
warning light :
► Dismount warning light.
► Attach the air pressure regulation unit to the drillings (12).
► Fix the warning light at the drillings (11) in the bracket (5).