Hestan KRD364GD-NG Guide d'installation

Catégorie
Cuisinières
Taper
Guide d'installation

Ce manuel convient également à

INDOOR COOKING
Dual-Fuel Range
KRD
Installation Manual
EN
©2019 Hestan Commercial Corporation
SAFETY DEFINITIONS
THIS INDICATES THAT DEATH OR SERIOUS INJURY MAY OCCUR
AS A RESULT OF NOT OBSERVING THIS WARNING.
THIS INDICATES THAT MINOR OR MODERATE INJURY MAY
OCCUR AS A RESULT OF NOT OBSERVING THIS WARNING.
THIS INDICATES THAT DAMAGE TO THE APPLIANCE OR
PROPERTY MAY OCCUR AS A RESULT OF NOT OBSERVING THIS
WARNING.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE
INSTALLING OR USING YOUR APPLIANCE TO REDUCE THE RISK OF FIRE,
BURN HAZARD, OR OTHER INJURY. KEEP THIS MANUAL FOR FUTURE
REFERENCE.
CAUTION
NOTICE
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
1. Do not try and light any appliance.
2. Do not touch any electrical switch.
3. Do not use any phone in your building.
4. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
5. If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency, or the gas
supplier.
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY,
A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY, OR DEATH.
INSTALLER: LEAVE THIS MANUAL WITH THE OWNER OF THE APPLIANCE.
HOMEOWNER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
TIP OVER HAZARD
A child or adult can tip over a range and be killed.
Check installation of the anti-tip device per the Installation Manual.
Do not operate the range without this device in place.
Check engagement of anti-tip device if range is moved, such as when cleaning behind the unit.
To check engagement, carefully tip the range forward while pulling from the rear of the unit. The
range should not move more that 1 inch [2.5cm].
Failure to follow these instructions can result in death or serious burns to children and adults.
To reduce the risk of burns, do not move this appliance while hot.
EN
©2019 Hestan Commercial Corporation
1
When properly cared for, your Hestan appliance will provide safe, reliable service for many years.
When using this appliance, basic safety practices must be followed as outlined below.
IMPORTANT: Save these instructions for the local Gas or Utility Inspector’s use.
INSTALLER: Please leave these Installation Instructions with the owner.
OWNER: Please retain these Installation Instructions for future reference.
This range is NOT designed for installation in manufactured (mobile) homes or recreational park
trailers. Do NOT install this range outdoors.
SAFETY PRECAUTIONS - BEFORE YOU BEGIN
ELECTRICAL SHOCK HAZARD
Disconnect power before installing or servicing appliance. Before turning
power ON, be sure all controls are in the OFF position. Failure to do so can
result in electrical shock or death.
ELECTRICAL GROUNDING
This appliance must be grounded. Grounding reduces the risk of electric shock
in the event of a short circuit. Read the ELECTRICAL CONNECTIONS section of this manual for
complete instructions.
This appliance is equipped with a 4-prong grounding plug for your protection against shock hazard
and should be directly plugged into a properly grounded receptacle. Do not cut or remove the
grounding prong from this plug.
ELECTRICAL SUPPLY
The appliance must be on its own dedicated circuit - 240 VAC, Single Phase, 60 Hz, with a current
rating as shown in the model number listing on pg. 2. Have the installer show you where the
electric circuit breaker is located so you know how to shut off the power to this appliance. It is the
responsibility of the user to have the appliance connected by a licensed electrician in accordance
with all local codes, or in the absence of local codes, in accordance with the National Electrical
Code. Read the ELECTRICAL CONNECTIONS section of this manual for complete details.
TABLE OF CONTENTS
1 SAFETY PRECAUTIONS - BEFORE YOU BEGIN
2 MODEL NUMBERS
3 RATING LABEL
3 REGULATORY / CODE REQUIREMENTS
3 LOCATION AND INSTALLATION / VENTILATION
14 BACKGUARD AND ACCESSORIES
15 INSTALLATION OF ANTI-TIP DEVICE
16 ELECTRICAL CONNECTIONS
18 GAS CONNECTION
20 FINAL SETUP
21 SERVICE
22 APPENDIX
EN
©2019 Hestan Commercial Corporation
2
MODEL NUMBERS
RANGE MODELS
MODEL NO. DESCRIPTION
CIRCUIT BREAKER
REQUIRED
KRD304-NG / -LP 30” DUAL-FUEL RANGE WITH 4 BURNERS 40 Amp
KRD365-NG / -LP 36” DUAL-FUEL RANGE WITH 5 BURNERS 40 Amp
KRD364GD-NG / -LP 36” DUAL-FUEL RANGE WITH 4 BURNERS & 12” GRIDDLE 40 Amp
KRD485GD-NG / -LP 48” DUAL-FUEL RANGE WITH 5 BURNERS, 2 OVENS, & 12”GRIDDLE 50 Amp
KRD484GD-NG / -LP 48” DUAL-FUEL RANGE WITH 4 BURNERS, 2 OVENS, & 24”GRIDDLE 50 Amp
KRD485GDKRD365
KRD364GD
KRD484GD
KRD304
EN
©2019 Hestan Commercial Corporation
3
REGULATORY / CODE REQUIREMENTS
Installation of this cooking appliance must be made in accordance
with local codes. In the absence of local codes, this unit should
be installed in accordance with the National Fuel Gas Code
ANSI
Z223.1/NFPA 54
, Natural Gas and Propane Installation code
CSA
B149.1
, or Propane Storage and Handling Code
B149.2
.
All Electrical Components must be electrically grounded in
accordance with local codes or in the absence of local codes with
the National Electrical Code
ANSI/NFPA 70
, or Canadian Electrical
code
CSA C22.1
.
STATE OF MASSACHUSETTS
Massachusetts requires all gas be installed using a plumber or gas fitter carrying the appropriate
Massachusetts license. All permanently installed natural gas or propane installations require a
T handle type manual gas valve be installed in the gas supply line to this appliance. Flexible gas
connector must not be longer than 48” [1.2 m].
CALIFORNIA PROPOSITION 65 - WARNING
WARNING This product can expose you to chemicals including carbon monoxide, which is
known to the State of California to cause birth defects or other reproductive harm.
For more information, go to www.P65Warnings.ca.gov.
RATING
LABEL
RATING LABEL
The rating label contains important information about your
Hestan appliance such as the model and serial number,
gas type and manifold pressure, electrical rating, the BTU
rating for each burner type, and the minimum installation
clearances.
The rating label is located in one of two places, as shown in
the figures on this page.
If service is necessary, contact Hestan Customer Care with
the model and serial number information shown on the label.
RATING LABEL
LOCATION AND INSTALLATION / VENTILATION
UNPACKING AND PLACEMENT
Remove the outer carton and packing materials from the shipping pallet. Do not remove the plastic
film covering the stainless-steel surfaces. This film protects the finish from scratches until the
appliance is installed in its final position.
The unit is very heavy and should be handled with care. Use proper safety equipment, such as gloves,
and at least 2 persons to move the appliance into position to avoid injury and to avoid damage to the
floor or the appliance itself.
DO NOT USE A HAND TRUCK OR DOLLY ON THE FRONT OR REAR OF THE
RANGE. HANDLE AND MOVE FROM THE SIDES ONLY.
Do not lift or carry the appliance by the oven door or handle. This could damage
the door hinges.
NOTICE
EN
©2019 Hestan Commercial Corporation
4
LOCATION AND INSTALLATION / VENTILATION
(CONTINUED)
The range is held onto the pallet with 4 large shipping bolts on both sides. Remove these bolts and
then move the range to the floor with the help of 2 persons.
PREPARATION
Before moving the range, protect any finished flooring and
secure the oven door(s) closed to prevent damage.
GAS AND ELECTRICAL SUPPLY CLEARANCES
If not already in place, install a gas shut-off valve in an
easily accessible location for servicing of the range. Make
sure all users of the range know where this shut-off is
located, and how to shut off the gas. Any openings in the
wall or floor behind the appliance must be sealed. The
Installation Clearances on the following pages show where
the “G” and “E” zones should be located.
The range is designed to be installed nearly flush to the rear
wall*. It may be necessary to reposition the gas supply and
power receptacle / junction box in order to accommodate the range when pushed back against the
wall.
Wall-mounted junction box may protrude no more than 2-3/8” [6.1 cm] from wall and still allow the
back of the range to be nearly flush to rear wall.
* Unless installed in an island with no rear wall.
GAS
SUPPLY
TO
APPLIANCE
SHUTOFF VALVE
IN OPEN POSITION
1-5/16"
[3.3 cm]
POWER
CORD
JUNCTION BOX
INSIDE WALL
CABINETRY
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space
located above the surface units should be avoided. If cabinet storage is to be provided, the risk can
be reduced by installing the required vent hood that projects horizontally a minimum of 5” [12.7 cm]
beyond the bottom of the cabinets.
2"
[5.1 cm]
RECEPTACLE
NEMA 14-50
JUNCTION
BOX
CONDUIT
EN
©2019 Hestan Commercial Corporation
5
OVEN DOOR REMOVAL
If you have a very narrow door opening to your kitchen, the oven door(s) can be removed.
REMOVE ONLY IF ABSOLUTELY NECESSARY. Door removal should only be done by a certified
installer or service technician. Be sure the oven has completely cooled and the electrical power is
off. Failure to do so may result in electric shock or burn injury. Use caution when removing the
door, it is very heavy. Be careful to disconnect the wire inside the door.
1. Open oven door completely.
2. Locate cover near hinge to access wire connector inside. Using small needle-nose pliers and a
small flat-blade screwdriver, disconnect the wires inside the door. [ A ]
3. At each hinge location, swing the hinge clip forward until it stops. A screwdriver may be
needed to do this. [ B ]
4. Gently close the oven door until it stops against the hinge clips, or approximately 30° from the
closed position. Hold on firmly to both sides of the door (not the handle) and pull the door
straight up off the hinges. Ask an assistant to help direct the wires out of the bottom of the
door so it does not hang up on anything. Place the oven door in a safe location until needed.
NEVER release the hinge clips and try to close the hinges. Doing so will snap the hinges closed
with great force which could cause injury. [ C & D ]
COVER PLATE
AND SCREW
HINGE CLIP
A
B
Hinge
clip
C
F
G
H
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
RE-INSTALL OVEN DOOR
1. Hold the door firmly on both sides (NOT FROM THE HANDLE) at approximately 30° from the
closed position and insert the hinges into the slots in the oven. The bottom edge of each hinge
has a notch which must seat inside the slot opening. DO NOT FORCE OR BEND OR TWIST
THE DOOR! [ E & F ]
2. Slowly open the door all the way. Swing the hinge clips away from you until completely inside
the slot opening and fully seated. A screwdriver may help you do this. [ G ]
3. Re-attach the wire connector and assure it is securely inside the door. Re-install the cover. [ H ]
4. Gently close the oven door to check for smooth operation.
EN
©2019 Hestan Commercial Corporation
6
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
LEVELING
The range must be level, especially those models featuring a griddle. Raise or lower the range to the
desired height by adjusting the leveling legs under the range. The legs can be turned by hand. It may
be necessary to use a lever or other lifting device to assist in temporarily raising the unit to turn the
legs. Do not lift or lever from the front or back, only from the sides.
Leveling 48” models: The 48” ranges have 6 legs. They should be adjusted so that all six share the
weight of the range.
The appliance top must be
level with or higher than
the adjacent countertop
surfaces. Failure to adjust
the height may expose the
adjacent cabinets to excessive
heat which may damage the
cabinets or countertop.
CAUTION
38-3/8 - 36-7/8”
[97.5 - 93.7]
TO COOKING
SURFACE
APPLIANCE
TOP
HANDLE
END CAP
COOKING
SURFACE
COMBUSTIBLE
MATERIALS
30-13/16”
[78.3]
24-11/16”
[62.7]
13” [33]
7” [17.7]
2-5/8”
[6.7]
MAX.
LOW
BACKGUARD
MAX.
RECESS
DEPTH
FINISHED
FLOOR
48-5/16”
[122.7]
3”
[7.6]
DIMENSIONS IN BRACKETS [ ] ARE IN CM.
LOCATION OF GAS AND
ELECTRICAL ON FLOOR
REF 1.12”
[2.84 cm]
EN
©2019 Hestan Commercial Corporation
7
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
G
ELECTRICAL
SUPPLY
LOCATION
FINISHED
FLOOR
VENT HOOD
E
COMBUSTIBLE
MATERIALS
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
W
V
DIMENSIONS IN
BRACKETS [ ] ARE
IN CM.
COUNTERTOP
FULL OVERLAY
DRAWER FACE
FULL OVERLAY
CABINET DOOR FACE
1
8
"
[3.2 mm]
INSTALLATION CLEARANCES 30” WITH LOW BACKGUARD
FRONT VIEW
18" [45.7]
MIN.
18"
[45.7]
7"
[17.8]
12"
[30.5]
1-1/2"
[3.8]
4"
[10.2]
11"
[27.9]
2-1/2"
[6.4]
RANGE MODEL
W
V (MIN)
KRD304 30” [76.2] 30” [76.2]
NOTES:
SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
“G” IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS
ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
“E” IS ELECTRICAL SUPPLY ZONE.
“W” IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
“V” IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
EN
©2019 Hestan Commercial Corporation
8
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
W
V
E
INSTALLATION CLEARANCES 36” WITH LOW BACKGUARD
FRONT VIEW
G
VALVE LOCATION
VENT HOOD
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
COMBUSTIBLE
MATERIALS
12”
[30.5]
2-1/2”
[6.4]
6”
[15.2]
5”
[12.7]
FINISHED
FLOOR
DIMENSIONS IN
BRACKETS [ ] ARE
IN CM.
3”
[7.6]
5”
[12.7]
19”
[48.3]
[24.1]
ELECTRICAL
SUPPLY
LOCATION
18” [45.7]
MIN.
9-1/2”
RECOMMENDED
GAS SHUT-OFF
[45.7]
18”
COUNTERTOP
FULL OVERLAY
DRAWER FACE
FULL OVERLAY
CABINET DOOR FACE
1
8
"
[3.2 mm]
RANGE MODEL
W
V (MIN)
KRD365 36” [91.4] 30” [76.2]
KRD364GD 36” [91.4] 30” [76.2]
NOTES:
SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE
NOT ALLOWED.
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
“G” IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS
ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
“E” IS ELECTRICAL SUPPLY ZONE.
“W” IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
“V” IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
EN
©2019 Hestan Commercial Corporation
9
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
DIMENSIONS IN BRACKETS [ ] ARE IN CM.
18” [45.7]
MIN.
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
VENT HOOD
COMBUSTIBLE
MATERIALS
4”
[10.2]
11”
[27.9]
23”
[58.4]
7”
[17.8]
ELECTRICAL
SUPPLY
LOCATION
1-1/2”
[3.8]
12”
[30.5]
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
FINISHED
FLOOR
[45.7]
18”
INSTALLATION CLEARANCES WITH LOW BACKGUARD
FRONT VIEW
48"
W
V
E
G
COUNTERTOP
FULL OVERLAY
DRAWER FACE
FULL OVERLAY
CABINET DOOR FACE
1
8
"
[3.2 mm]
RANGE MODEL
W
V (MIN)
KRD485GD 48” [121.9] 30” [76.2]
KRD484GD 48” [121.9] 30” [76.2]
NOTES:
SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS
ARE NOT ALLOWED.
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE
ADJACENT COUNTERTOP SURFACES.
“G” IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS
ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
“E” IS ELECTRICAL SUPPLY ZONE.
“W” IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
“V” IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
EN
©2019 Hestan Commercial Corporation
10
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
INSTALLATION CLEARANCES WITH ISLAND TRIM
SIDE VIEW
FINISHED
FLOOR
38-3/8 - 36-7/8”
[97.5 - 93.7]
TO COOKING
SURFACE
48-5/16”
[122.7]
DIMENSIONS IN BRACKETS [ ] ARE IN CM.
LOCATION OF GAS
AND ELECTRICAL
ON FLOOR
ISLAND
TRIM
For Island Trim installations,
counter surface should
have a cantilever surface
meeting the rear of
the Island Trim
MIN. CLEARANCE
TO COMBUSTIBLE
SURFACES WITH
ISLAND TRIM
COMBUSTIBLE
MATERIALS
30-13/16”
[78.3]
24-11/16”
[62.7]
12”
[30.5]
3”
[7.6]
MAX.
RECESS
DEPTH
APPLIANCE
TOP
COOKING
SURFACE
7” [17.7]
2-5/8”
[6.7]
HANDLE
END CAP
REF 1.12”
[2.84 cm]
EN
©2019 Hestan Commercial Corporation
11
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
G
ELECTRICAL
SUPPLY
LOCATION
FINISHED
FLOOR
E
COMBUSTIBLE
MATERIALS
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
W
V
DIMENSIONS IN
BRACKETS [ ] ARE
IN CM.
COUNTERTOP
FULL OVERLAY
DRAWER FACE
FULL OVERLAY
CABINET DOOR FACE
1
8
"
[3.2 mm]
INSTALLATION CLEARANCES 30” WITH ISLAND TRIM
FRONT VIEW
1-1/2"
[3.8]
4"
[10.2]
11"
[27.9]
2-1/2"
[6.4]
7"
[17.8]
18"
[45.7]
12"
[30.5]
NOTES:
SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
“G” IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS
ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
“E” IS ELECTRICAL SUPPLY ZONE.
“W” IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
“V” IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
RANGE MODEL
W
V (MIN)
KRD304 30” [76.2] 30” [76.2]
EN
©2019 Hestan Commercial Corporation
12
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
COUNTERTOP
FULL OVERLAY
DRAWER FACE
FULL OVERLAY
CABINET DOOR FACE
1
8
"
[3.2 mm]
12”
[30.5]
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
FINISHED
FLOOR
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
COMBUSTIBLE
MATERIALS
DIMENSIONS IN
BRACKETS [ ]
ARE IN CM.
3”
[7.6]
5”
[12.7]
6”
[15.2]
5”
[12.7]
2-1/2”
[6.4]
19”
9-1/2”
[24.1]
ELECTRICAL
SUPPLY
LOCATION
[48.3]
[45.7]
18”
INSTALLATION CLEARANCES 36” WITH ISLAND TRIM
FRONT VIEW
W
V
G
E
RANGE MODEL
W
V (MIN)
KRD365 36” [91.4] 30” [76.2]
KRD364GD 36” [91.4] 30” [76.2]
NOTES:
SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
“G” IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS
ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
“E” IS ELECTRICAL SUPPLY ZONE.
“W” IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
“V” IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
EN
©2019 Hestan Commercial Corporation
13
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
INSTALLATION CLEARANCES 48" WITH ISLAND TRIM
FRONT VIEW
W
V
E
G
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
ELECTRICAL
SUPPLY
LOCATION
FINISHED
FLOOR
COMBUSTIBLE
MATERIALS
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
7”
[17.8]
12”
[30.5]
4”
[10.2]
1-1/2”
[3.8]
11”
[27.9]
23”
[58.4]
[45.7]
18”
COUNTERTOP
FULL OVERLAY
DRAWER FACE
FULL OVERLAY
CABINET DOOR FACE
1
8
"
[3.2 mm]
DIMENSIONS IN
BRACKETS [ ] ARE
IN CM.
RANGE MODEL
W
V (MIN)
KRD485GD 48” [121.9] 30” [76.2]
KRD484GD 48” [121.9] 30” [76.2]
NOTES:
SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
“G” IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS
ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
“E” IS ELECTRICAL SUPPLY ZONE.
“W” IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
“V” IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
EN
©2019 Hestan Commercial Corporation
14
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
BACKGUARD AND ACCESSORIES
Sheetmetal accessories such as the backguard, and areas at the rear of the range may have sharp
edges. Wear work gloves while handling and installing these items.
BACKGUARD
Your Hestan range is supplied at the factory with an Island Trim backguard. See Table 1 in the
APPENDIX section of this manual for other backguard options available from your Hestan dealer.
Selection of the appropriate backguard depends on the installation location and adjacent materials,
and the type of vent hood to be used. Installation instructions are included with the backguard
kit. A LOW OR TALL BACKGUARD IS REQUIRED WHEN INSTALLING THE RANGE AGAINST A
COMBUSTIBLE SURFACE - THE ISLAND TRIM IS NOT SUITABLE.
The top of the backguard serves as an exhaust for the oven when in operation, and as an exhaust vent
to remove heat from under the cooktop section of the range as well. DO NOT BLOCK or obstruct
the top of the backguard. DO NOT touch the top of the backguard during appliance operation as it
may get hot. Allow sufficient time to cool before touching or cleaning this area.
DO NOT position plastic or other heat-sensitive items nearby which could melt or burn.
Griddle Vent - Units with gas griddle have a vent at the rear which must not be obstructed. Do not
attempt to operate the griddle with anything covering or obstructing the griddle vent.
CAUTION
VENTILATION REQUIREMENTS
It is strongly recommended that this appliance be installed with a Hestan vent hood. Due to the high
heat output of this range, it is very important that the hood and ductwork installation meets local
building codes and is installed by a qualified technician.
Do not use a down-draft style ventilation system.
Do not mount a microwave oven/ventilator combination above the range. These type of units do not
have sufficient airflow to remove the high heat output of this range and were not tested with this
type of appliance.
For non-Hestan approved vent hoods, the vent hood and/or blower unit must be rated for 1 CFM
[1.7 m³/hr] for every 100 BTU [.03 kW].
If the range has a 12” Griddle, add an additional 200 CFM [340 m³/hr] to the blower capacity.
If the range has a 24” Griddle, add an additional 400 CFM [680 m³/hr] to the blower capacity.
For island applications, it is recommended to use a vent hood that is 6” [15.2 cm] wider than the
appliance, to allow for 3” [7.6 cm] of overlap on the left and right of the appliance.
Keep duct runs as short and straight as possible. Elbows and transition fittings reduce airflow
efficiency. Hestan recommends keeping the duct run under 50 ft. [15.2 m].
CONSULT WITH YOUR HESTAN DEALER ON SELECTING THE APPROPRIATE
VENT HOOD FOR YOUR HESTAN APPLIANCE.
CAUTION
EN
©2019 Hestan Commercial Corporation
15
INSTALLATION OF ANTI-TIP DEVICE
THE ANTI-TIP DEVICE PROVIDED WITH THIS RANGE
MUST BE INSTALLED.
PREPARATION
POSSIBLE PROPERTY DAMAGE - Use a qualified installer or contractor to
determine the proper method of attaching the anti-tip bracket to the rear wall
or floor behind your range. Special drills or tools may be needed to drill holes in the wall or floor
(ceramic tile, hardwood flooring, etc.).
ELECTRICAL SHOCK HAZARD - Use extreme caution when drilling holes
into the wall or floor as there may be hidden wires. Identify the electrical
circuits that could be affected by the installation of the anti-tip bracket.
Shut off the power to these circuits. Failure to follow these instructions may result in death or
electrical shock.
HOLE PREPARATION
The anti-tip bracket must be installed in sound materials, such as wood studs in the wall AND floor
joists under the finished floor. They must be able to withstand the forces exerted on the bracket by
the range should it tip-over. If wood studs or other suitable materials are not in the designated area
behind the range, you must attach the bracket using appropriate drywall anchors or similar fasteners.
DRYWALL INSTALLATION: After positioning the bracket as per the diagram below, mark the holes
and drill the appropriate holes as per the instructions supplied with the wall anchors. For hardboard
or solid plaster walls, you may need different wall anchors, available at your local hardware store or
home center.
WOOD FLOOR INSTALLATION: After positioning the bracket as per the diagram below, mark the
holes and drill the appropriate holes for #12 or similar, large wood screws, at least 1.5” [3.8 cm] in
length. Use washers as well. All hardware is available at your local hardware store or home center.
CONCRETE FLOOR INSTALLATION: After positioning the bracket as per the diagram below, mark
the holes and drill the appropriate holes for #12 or similar large masonry anchors, at least 1.5” [3.8 cm]
in length. Use washers as well. All hardware is available at your local hardware store or home center.
NOTICE
X
RANGE MODEL
X
30”, 36” 1-1/16” [2.7]
48” 3-1/4” [8.3]
EN
©2019 Hestan Commercial Corporation
16
INSTALLATION OF ANTI-TIP DEVICE
(CONTINUED)
ANTI-TIP BOLT ADJUSTMENT
After leveling the range, and after the bracket has been attached, adjust the anti-tip bolt and large
washer under the range so the top of the washer is 1-1/4” [3.2 cm] maximum from the floor. Slide
the range into the opening of the bracket and verify the bolt is engaged in the bracket as seen
below. Carefully tip the range forward to check. The range should not move more than 1” [2.5 cm].
ELECTRICAL CONNECTIONS
ELECTRICAL SHOCK HAZARD
Disconnect power before installing or servicing appliance. Before turning
power ON, be sure all controls are in the OFF position. Failure to do so can
result in electrical shock or death.
ELECTRICAL GROUNDING
This appliance must be grounded. Grounding reduces the risk of electric
shock in the event of a short circuit. Grounding through the neutral conductor is prohibited for
new branch circuit installations (1996 NEC), mobile homes, and recreational vehicles, or in an area
where local codes prohibit it. This range has been setup at the factory for a 4-wire connection.
CAUTION
Improper grounding will cause malfunctions in the unit, such as
continuous sparking of the igniters. This can damage the appliance and
create a shock hazard condition.
ELECTRICAL CONNECTION
The appliance may be connected using the cordset provided, or may be hard-wired. The appliance
must be on its own dedicated circuit - 240 VAC, Single Phase, 60 Hz, with a current rating as shown
in the model number listing on pg. 2. The installation must be done in accordance with local codes,
or in the absence of local codes, it must be installed in accordance with the National Electrical
Code, ANSI/NFPA 70.
For both US and CANADA installations: This appliance is equipped with
copper lead wires and must be connected to copper wires only. Improper
connection of aluminum house wiring can result in a fire or shock hazard.
Use only connectors designed and certified for connecting to aluminum
wire, and installed by a qualified electrician.
EN
©2019 Hestan Commercial Corporation
17
4-WIRE CONNECTION
For installations where grounding through the neutral
conductor is prohibited. Use only 4-conductor cord
kits rated 125/250 Volts (min), 50 Amps, and labeled
“For Use with Ranges”. Your Hestan range is pre-wired
at the factory for a 4-wire connection and includes this
cordset.
1. Make sure power is off at the supply panel /
breaker.
2. Remove the narrow access panel at the rear of
the range and locate the chassis ground terminal.
Attach GREEN ground appliance wire of supply
circuit or cord to chassis using ground screw.
3. Connect WHITE neutral appliance wire to WHITE
neutral wire in electrical box.
4. Connect RED (L1) appliance wire to RED power
wire in electrical box.
5. Connect BLACK (L2) appliance wire to BLACK
power wire in electrical box.
6. Tighten all connections. Strain relief must be
installed.
STRAIN RELIEF /
BRIDE DE CORDON
POWER CORD /
CORDON D’ALIMENTATION
GROUND TERMINAL /
BLOC DE MISE
À LA TERRE
3-WIRE CONNECTION
For installations where grounding through the neutral
conductor is allowed. Use only 3-conductor cord kits
rated 125/250 Volts (min), 50 Amps, and labeled “For
Use with Ranges”. This cordset is available at hardware
stores and home centers.
1. Make sure power is off at the supply panel / breaker
off.
2. Attach WHITE neutral appliance wire to WHITE
neutral wire in electrical box and use GREEN
ground jumper wire to connect to neutral as shown
here.
3. Connect RED (L1) appliance wire to RED power
wire in electrical box.
4. Connect BLACK (L2) appliance wire to BLACK
power wire in electrical box.
5. Tighten all connections. Strain relief must be
installed.
STRAIN RELIEF /
BRIDE DE CORDON
POWER CORD /
CORDON D’ALIMNENTATION
GROUND TERMINAL /
BLOC DE MISE
À LA TERRE
JUMPER WIRE /
FIL CONNECTEUR
ELECTRICAL CONNECTIONS
(CONTINUED)
EN
©2019 Hestan Commercial Corporation
18
GAS SUPPLY
The local gas authority or supplier should be consulted at the installation planning stage in order to
establish the availability of an adequate supply of gas (NG or LP). If it is a new installation, have the
gas authorities or supplier check the meter size and piping to assure that the unit is supplied with the
necessary amount of gas supply and pressure to operate the unit(s).
Gas connections should be made by a qualified plumber, or your professional appliance installer.
All appliances must be fitted with an accessible upstream gas shutoff valve as a means of isolating the
appliance for emergency shut off and for servicing.
Make certain new piping and connections have been made in a clean manner and have been purged
so that piping compound, chips, etc. will not clog regulators, valves, orifices, or burners. Use pipe
joint compound / thread sealant approved for natural and LP gases.
The appliance and its individual manual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2 psi [3.5
kPa].
The appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of that system at test pressures equal to or less than 1/2 psi
[3.5 kPa].
NEVER CONNECT THE APPLIANCE TO AN UNREGULATED GAS SUPPLY. Before proceeding,
ensure the appliance is fitted for Natural or Liquid Propane gas. Connecting to an improper gas type
will result in poor performance and increased risk of damage or injury. Gas type and gas consumption
(BTU per hour) for each burner type is shown on the rating label.
Installation of this cooking appliance must be made in accordance with local codes. In the absence of
local codes, this unit should be installed in accordance with the National Fuel Gas Code No.
Z223.1/
NFPA 54
, Natural Gas and Propane Installation code
CSA B149-1
, or Propane Storage and Handling
Code B149.2.
NOTE: See rating label for manifold pressure for the type of gas of your appliance.
REGULATOR LOCATION
Some range units may have the regulator mounted
internally as seen in Figure A. There is a short flex
hose which ends at a small bracket at the rear of the
range. This short flex hose has a connection end
with 1/2”NPT internal thread AND 3/4”NPT external
threads. The installer must connect a gas supply
hose at this location.
Other units have the regulator located externally
with a short flex hose and mounted to the rear of
the range with a bracket as shown in Figure B. The
regulator is shipped loose in the accessory box with
other items. The regulator must be connected to the
provided short flex hose by the installer, and then
the gas supply hose to the inlet side of the regulator.
Make a note of the flow arrow embossed on the
regulator itself. The arrow points toward the range.
The gas inlet of the regulator is 1/2”NPT thread.
Connect to the gas supply using a mininum 3/4” inside diameter (1” OD) flexible (semi-rigid) stainless
steel gas hose (not included) with appropriate fittings to prevent gas starvation. This hose should be
no more that 48” [1.2m] in length. Use the appropriate thread sealant on all connections, except flare
fittings.
The gas hose must not interfere with the rear of the range. Use caution when pushing the range
against the back wall, so that you do not kink or crimp the hose as this could result in a gas leak.
1/2”NPT
INTERNAL THREAD
FIGURE A: INTERNAL REGULATOR
3/4”NPT
EXTERNAL THREAD
GAS CONNECTION
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Hestan KRD364GD-NG Guide d'installation

Catégorie
Cuisinières
Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues