R
PLA3544Q/PGA300RFSTM000,REV.B,160x80mm80G
, ROHS2.0,REACH,POPs,PAHS,PROP65,
ERP机型:PLA3544Q-GL-SMT00030A-V1
描述:
ERP P/N:
REV0.1
Designed:Walter Date:2022-05-07
K
Access Control power supply will activate the Wireless
Transceiver. Wireless Transceiver Blue light indicator will be ON
once connected to Ingress or Ingress Vision. Refer to the
Ingress/Ingress Vision Manual for pairing instructions.
Short Press the wireless transceiver pairing button to start
connecting with Ingress/Vision, Blue light indicator flashes when
pairing starts. It will automatically exit pairing mode if pairing is
successful. If pairing is unsuccessful, it will continue to flash and
automatically exits in 3 minutes.
Short press the wireless transceiver pairing button again to
re-enter pairing mode.
1) When wireless transceiver is activated through the smart access control
power supply, the Blue light indicator turns ON when the door locks or unlocks.
2) When the electromagnetic lock (LOCK NC) is triggered, the Blue light
indicator turns ON.
3. Pair Wireless Transceiver to the Lockly Guard Ingress or Ingress Vision
4. How Wireless Transceiver and Ingress/Ingress Vision Works
Lockly Guard Wireless Transceiver is built with F433.92MHz and Lockly 2.0
proprietary encryption to provide
stable wireless connectivity, security and
reliability. It operates on 12V DC from the Access Control power supply and
supports high-level or low-level of PUSH and monitors door open/closed status
of the electromagnetic lock*. It is very quick and easy to install anywhere.
Insert cables through the bottom hole and connect to
corresponding wireless transceiver terminals : PUSH
GND, GND, +12V and LOCK NC. Then connect the
cables to the corresponding terminals on the Access
Control Power Supply : PUSH, V-, V+ and LOCK NC to
electromagnetic lock NC terminal. Ensure you
followed the wiring diagram and cables are connect-
ed to the corresponding terminals. Tighten the screws
to secure the cables.
WIRELESS TRANSCEIVER (PGA300RF)
Installation & User Manual
WWW.LOCKLYPRO.COM
2. Refer to the wiring diagram
1. To remove cover,
slide the bottom of
the case as shown.
*Works ONLY with Lockly Electromagnetic Lock. Connection to NC of
the LOCK NC cable is required.
The NC port is used to detect the opening and closing status of the door.
Only the Lockly Guard Electromagnetic Lock supports this function. If
you use a third-party Electromagnetic Lock other than the Lockly Guard
Electromagnetic Lock, you do not need to connect this NC cable.
Note
Wirelless Transceiver
Access Control Power Supply
Electromagnetic Lock
+12V
GND
PUSH GND
PUSH 12V
LOCK NC
WARNING: This product can expose you to chemicals including Lead,
which is known to the State of California to cause cancer. For more
information go to www.P65Warnings.ca.gov.
FCC Warning:
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
NOTE 1: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE 2: Any changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user's authority to operate the
equipment.
FCC Radiation Exposure Statement
The Secure Link Wi-Fi Hub complies with FCC radiation exposure limits set forth
for an uncontrolled environment. It should be installed and operated with
minimum distance 20cm between the radiator & your body.
IC WARNING
This device contains licence-exempt transmitter(s) that comply with
Innovation,Science and Economic Development Canada’s licence-exempt
RSS(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may
cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est
conforme aux CNR d’Innovation, Sciences et Développement économique
Canada applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
1. L’appareil ne doit pas produire de brouillage;
2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le fonctionnement.
IC Radiation Exposure Statement
This equipment meets the exemption from the routine evaluation limits in
section 2.5 of RSS-102. It should be installed and operated with a minimum
distance of 20cm between the radiator and any part of your body.
Cet équipement est conforme à l'exemption des limites d'évaluation habituelle
de la section 2.5 de la norme RSS-102. Il doit être installé et utilisé à une distance
minimale de 20 cm entre le radiateur et toute partie de votre corps.
正面 正面
正面
成型尺寸:80x40mm