1) Attach mounting strap to outlet box using the (2) two
supplied mounting strap screws. Mounting strap can be
adjusted to suit position of fixture.
2) Grounding instructions: (See Illus. A or B).
A) On fixtures where mounting strap is provided with a
hole and two raised dimples. Wrap ground wire from
outlet box around green ground screw, and thread into
hole.
B) On fixtures where a cupped washer is provided. Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
If fixture is provided with ground wire. Connect fixture
ground wire to outlet box ground wire with wire connector.
After following the above steps. Never connect ground wire
to black or white power supply wires.
3) Make wire connections. Reference chart below for correct
connections and wire accordingly.
4) Push fixture to wall, carefully screw in the (4) fixture mount-
ing screws through holes in the sides of the canopy. NOTE,
the fixture can be mounted with the glass in the up or down
position.
5) Insert recommended bulb (not included).
6) Set glass down over socket.
7) Thread the three (3) thumbscrews into the base as shown.
(DO NOT over tighten.)
GREEN GROUND
SCREW CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
AB
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.) Neutral Wire
GLASS
THUMBSCREW(S)
(4)FIXTURE
MOUNTING SCREWS
OUTLET
BOX
WIRE
CONNECTOR(S)
MOUNTING STRAP
WITH GROUND SCREW
(2)STRAP
MOUNTING SCREWS
Date Issued: 06/15/16 IS-45295-US
Estamos aquí para ayudarle 866-558-5706
Horario: Lunes-Viernes 9am a 5pm EST (hora oficial del este)
PRECAUCIÓN – RIESGO DE DESCARGA ELÉCTRICA –
Desconecte la electricidad en el panel principal del interruptor
automático o caja principal de fusibles antes de comenzar y
durante la instalación.
1) Acople la correa del montaje a la caja de salida usando la (2)
dos suministrados Montaje correa de tornillos. Correa de
montaje puede ajustarse para adaptarse a la posición de la
luminaria.
2) Instrucciones para poner a tierra: (Ver Ilustraciones A o B).
A) En artefactos donde se suministra la abrazadera de
montaje con un agujero y dos depresiones onduladas.
Envuelva el conductor de tierra de la caja de salida
alrededor del tornillo de tierra verde y atornille en el
agujero.
B) En artefactos donde se suministra una arandela
cóncava. Fije el conductor de tierra de la caja de salida
debajo de la arandela cóncava y el tornillo de tierra
verde y enrosque en la abrazadera de montaje.
Si se suministra el artefacto con conductor de tierra. Co-
necte el conductor de tierra del artefacto al conductor de
tierra de la caja de salida con conector de tierra después
de seguir los pasos anteriores. Nunca conecte el conductor
de tierra a los alambres de alimentación eléctrica negros o
blancos.
3) Haga las conexiones de alambres. No se provee conectores.
Consulte la tabla de abajo para hacer las conexiones cor-
rectas y haga las conexiones omo corresponda.
4) Empuje la luminaria a la pared, atornille cuidadosamente el
(4) accesorio de tornillos a través de agujeros en los lados
del dosel. Tenga en cuenta que el aparato puede montarse
con el vidrio ni la posición hacia abajo.
5) Inserte la bombilla recomendada (no incluida).
6) Coloque el vidrio hacia abajo sobre el zócalo.
7) Enrosque los tornillos de tres 3 en la base como se muestra.
(No apriete demasiado.)
ARANDELA
CONCAVA
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
DEPRESIONES
TIERRA
ARTEFACTO
CONECTOR DE ALAMBRE
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
TIERRA
ARTEFACTO
AB
Conectar el alambre de
suministro negro o rojo al
Conectar el alambre de
suministro blanco al
Negro Blanco
*Cordon paralelo (redondo y liso) *Cordon paralelo (cuadrado y estriado)
Claro, marrón, amarillio o negro
sin hebra identificadora
Claro, marrón, amarillio o negro
con hebra identificadora
Alambre aislado (diferente del verde)
con conductor de cobre
Alambre aislado (diferente del
verde) con conductor de plata
*Nota: Cuando se utiliza alambre paralelo
(SPT I y SPT II). El alambre neutro es de forma
cuadrada o estriada y el otro alambre será de
forma redonda o lisa. (Vea la ilustracíón). Hilo Neutral
GLASS
THUMBSCREW(S)
(4)FIXTURE
MOUNTING SCREWS
OUTLET
BOX
WIRE
CONNECTOR(S)
MOUNTING STRAP
WITH GROUND SCREW
(2)STRAP
MOUNTING SCREWS
Date Issued: 06/15/16 IS-45295-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fuse
box before starting and during the installation.
INSTRUCTIONS
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
1) Attach mounting strap to outlet box using the (2) two
supplied mounting strap screws. Mounting strap can be
adjusted to suit position of fixture.
2) Make wire connections. Reference chart below for correct
connections and wire accordingly.
3) Push fixture to wall, carefully screw in the (4) fixture mount-
ing screws through holes in the sides of the canopy. NOTE,
the fixture can be mounted with the glass in the up or down
position.
4) Insert recommended bulb (not included).
5) Set glass down over socket.
6) Thread the three (3) thumbscrews into the base as shown.
(DO NOT over tighten.)
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.) Neutral Wire
GLASS
THUMBSCREW(S)
(4)FIXTURE
MOUNTING SCREWS
OUTLET
BOX
WIRE
CONNECTOR(S)
MOUNTING STRAP
WITH GROUND SCREW
(2)STRAP
MOUNTING SCREWS
Date Issued: 06/15/16 IS-45295-CB
INSTRUCTIONS
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
Nous sommes là pour vous aider 866-558-5706
Heures : du lundi au vendredi, de 9h à 17h (heure de l’Est)
ATTENTION – RISQUE DE DÉCHARGES ÉLECTRIQUES -
Couper le courant au niveau du panneau du disjoncteur du
circuit principal ou de la boîte à fusibles principale avant de
procéder à l’installation.
1) Fixer la sangle de fixation au boîte de sortie à l’aide des (2)
deux vis sangle fournies. Sangle de fixation peut être ajusté
en fonction de la position de l’appareil.
2) Rendre les connexions des fils. Référence tableau suivant
pour les connexions correctes et fil en conséquence.
3) Luminaire pousser au mur, visser avec précaution dans les
(4) Montage Montage de vis dans les trous dans les côtés
de la canopée. Notez que l’appareil peut être monté avec le
verre dans le haut ou vers le bas.
4) Insérer recommandé ampoule (non inclus).
5) Placez verre sur socket.
6) Visser les vis à ailettes trois 3 dans la base comme indiqué.
(Ne pas trop serrer.)
Connecter le fil noir ou
rouge de la boite Connecter le fil blanc de la boîte
A Noir A Blanc
*Au cordon parallèle (rond et lisse) *Au cordon parallele (à angles droits el strié)
Au bransparent, doré, marron, ou
noir sans fil distinctif
Au transparent, doré, marron, ou
noir avec un til distinctif
Fil isolé (sauf fil vert) avec
conducteur en cuivre
Fil isolé (sauf fil vert) avec
conducteur en argent
*Remarque: Avec emploi d’un fil paralléle
(SPT I et SPT II). Le fil neutre est á angles
droits ou strié et l’autre fil doit étre rond ou
lisse (Voir le schéma). Fil Neutre
VERRE
VIS À OREILLES
(4)VIS DE
FIXATION DE LUMINAIRE
BOÎTE
À PRISES
CONNECTEURS
DE FIL
SANGLE DE FIXATION
AVEC VIS DE TERRE
VIS DE L’ÉTRIER
DE MONTAGE