INSTALLATION INSTRUCTION
Loft
WS-3618, WS-3624, WS-3632
HARDWARE
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the OFF” position and unscrew the fuse(s) or
switch ”OFF” the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out
or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en
position d’arrêt (« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, nen laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta
lación de esta lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la
instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
A1 B1 C1 H1 I1
Wire Connector
Qty: 3
7EAC112201
Junction Box Screw
Qty: 2 + 1 Extra
7MPF0415C2
#8-32x9/16 SS
Fixture Screw
Qty: 1 Extra
7MPF0408S1
5/32”-32x5/16
Nickel Plating
Mounting Screw
Qty: 4 + 1 Extra
7MPF0306C4
1/8”-40x1/4
Nickel Plating
Glass Holder
Qty: 2
4MBC480501CH (CH)
4MBC480501BN1 (BN)
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. 2
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the mounting hardware.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary
for installation.
CONNECTING THE WIRES (Fig. 2)
3. Remove screws (C1) from the xture.
4. Connect the xture wires to supply wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured. If your outlet box has a
green or bare copper ground wire, connect the xtures ground wire (M1) to it. Otherwise, connect the xture’s ground wire directly to the back
plate (D1) using the green screw (E1) provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
5. Secure mounting back plate (D1) to the junction box (F1) using junction box screws (B1).
The side of the mounting back plate marked “GND” must face out.
6. Place the xtures canopy plate (L1) over the mounting
back plate (D1) and secure with screws (C1).
7. Slide the glass shade (G1) into the front bracket (N1).
While supporting the glass, attach glass holder (H1) to
the front bracket with screws (I1) to secure the glass in place.
INSTALLATION INSTRUCTION
Loft
WS-3618, WS-3624, WS-3632
E1
A1
D1
B1
C1
I1
H1
N1
L1
FIG.1
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig.2 Wiring
Junction Box
Ground Wire
Mounting Backplate
Black Fixture Wire
White Fixture Wire
Canopy Plate
Front Bracket
Glass Holder
Screw
Glass
Wire Connector
Junction Box
Screw