Osburn OP00025 Guide d'installation

Catégorie
Poêles
Taper
Guide d'installation
Operation Manual
2500
(OP00025 Model)
Safety tested according to ULC S627,
UL 1482 and ASTM E1509 by an
accredited laboratory.
INSTALLATION BY A
PROFESSIONAL IS STRONGLY
RECOMMENDED
Printed in Canada 45910_OA
READ AND KEEP THIS MANUAL FOR REFERENCE
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS
IN LOCAL AREA.
READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET FUEL-BURNING ROOM HEATER. FAILURE TO
FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
ENGLISHFRANÇAIS
2022-01-24
Page 3Operation Manual - 2500
ENGLISH
RECOMMENDATIONS
It is highly recommended that this appliance be installed and serviced by professionals who are
certified in the United States by NFI (National Fireplace Institute ® ) or in Canada by WETT (Wood
Energy Technology Transfer) or in Quebec by APC (Association des Professionnels du Chauffage).
If this appliance is not properly installed, combustible materials near it may overheat and
catch fire. To reduce the risk of fire, follow the installation instructions in this manual exactly. Contact
local building or fire officials about restrictions and installation inspection requirements in local area. It
is also recommended to inform your home insurance company.
It may be needed to get a building permit for the installation of this appliance and the venting system
that it is connected to.
Read this entire manual before operating this stove.
SAFETY INFORMATION
Using a stove with cracked or broken components, such as glass or baffle may produce an unsafe
condition and may damage the stove.
The viewing door must be closed and latched at all times during operation. The ash drawer access
panel must also be closed during operation.
A smoke detector, a carbon monoxide detector and a fire extinguisher should be installed in the
house. The location of the fire extinguisher should be known by all family members.
Do not disable sensors and safety switches.
This product can expose you to chemicals including carbon monoxide, which is
known to the State of California to cause cancer, birth defects or other reproductive
harm. For more information go to www.P65warnings.ca.gov/
GENERAL INFORMATION
It is highly recommended to buy this product from a retailer who can provide installation and
maintenance advice.
The stove will not operate during a power outage. If an outage does occur, check the stove for
smoke spillage. Opening a window will prevent negative pressure and smoke spillage in the room.
This stove has been developed and built to be used as a residential heater. Commercial or industrial
use is prohibited and will void the warranty.
This heating unit is designed to serve as a supplementary heat source. We recommend that a
primary heat source also be available in the home. The manufacturer cannot be responsible for costs
associated with the use of another heating system.
DANGER
HOT WHILE IN OPERATION, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY.
CONTACT MAY CAUSE SKIN BURNS.
Page 4 Operation Manual - 2500
ENGLISH
This stove must be connected to a standard 120V / 60Hz, grounded electrical outlet. Do not use
an outlet adapter, an extension cord or sever the grounding plug. Do not route the electrical cord
underneath, in front or over the stove.
It is important that adequate oxygen is being supplied to the fire for proper combustion. At all time,
make sure the outside air register is not obstructed by ice, snow or other objects as this will starve the
fire of air and prevent the proper operation of the stove.
Mixing of appliance components from different sources or modifying components is prohibited and
will void the warranty.
Any modification to the stove that has not been approved in writing by the testing authority is prohibited
and violates CSA B365 (Canada), and ANSI NFPA 211 (USA).
Stove builder international inc. (SBI) grants no warranty, implied or stated, for the poor installation or
lack of maintenance of your appliance and assumes no responsibility of any consequential damages.
This stove is certified to comply with EPA NSPS 2015 particulate emission standards and is not
approved for sale after May 15th 2020.
REGISTER YOUR WARRANTY ONLINE
Should warranty service be required, you must show proof of purchase. Keep
your sales invoice. The date on these records establishes the warranty period.
If proof of purchase cannot be supplied, the warranty period will be determined
from the date of manufacture of the product.
We also recommend that you register your warranty online at:
https://www.osburn-mfg.com/en/warranty/warranty-registration/
Registering your warranty online will help us to quickly track the information we
need about your stove.
AVAILABLE OPTIONS AND ACCESSORIES
Hopper extension;
Fresh air kit;
Wall thermostat;
Programmable thermostat;
Glass hearth pad;
For more details, visit our web site www.osburn-mfg.com or refer to an authorized dealer.
Page 5Operation Manual - 2500
ENGLISH
TABLE OF CONTENTS
Recommendations ................................................................................................................... 3
Safety Information .................................................................................................................... 3
General Information .................................................................................................................. 3
Available Options and Accessories ......................................................................................... 4
Specifications ........................................................................................................................... 7
Certification Label ...............................................................................................................8
Fuel ........................................................................................................................................... 9
Recommended Pellets .........................................................................................................9
Storage ..............................................................................................................................9
Stove Controls ........................................................................................................................ 10
Stove Operation ...................................................................................................................... 11
Before Operating the Stove ................................................................................................11
First Startup / Beginning of Season ....................................................................................12
Every Day Startup and Use ................................................................................................12
Running Out of Pellets .......................................................................................................12
Shutting Down Procedure ..................................................................................................13
Signs of an Overheating Stove ...........................................................................................13
Using a Thermostat ...........................................................................................................14
Pilot Mode Selection ....................................................................................................14
Convection adjustments ....................................................................................................14
Air Intake Adjustments .......................................................................................................15
Maintenance ........................................................................................................................... 16
Maintenance Schedule .......................................................................................................16
Recommended tools..........................................................................................................17
Ash removal ......................................................................................................................17
Burn pot ...........................................................................................................................18
Combustion Chamber ........................................................................................................ 18
Glass Maintenance ............................................................................................................19
Replacing the Glass ...........................................................................................................19
Maintaining Door Gasket .................................................................................................... 21
Adjusting the Door .............................................................................................................21
Verifying the Door Seal .......................................................................................................21
Heat Exchangers and Exhaust Channels .............................................................................22
Baffle ................................................................................................................................ 23
Maintaining the Venting System ..........................................................................................24
Facing a Chimney Fire ..................................................................................................24
Fly Ash and Soot ..........................................................................................................24
Page 6 Operation Manual - 2500
ENGLISH
Troubleshooting ...................................................................................................................... 25
Main Error Codes ..............................................................................................................25
CODE P ........................................................................................................................ 25
CODE E ........................................................................................................................ 25
CODE L ........................................................................................................................26
CODE H .......................................................................................................................26
CODE d ........................................................................................................................26
CODE C .......................................................................................................................26
Other possible error codes............................................................................................27
Recommandations ................................................................................................................. 32
Page 7Operation Manual - 2500
ENGLISH
SPECIFICATIONS
Model 2500 (OP00025)
Fuel Type1Wood pellets (Premium grade or better)
Recommended heating area (sq. ft.)2500 - 2,000 pi2 (46 - 186 m2)
Hopper capacity 60 lb (27,3 kg)
Maximum burn time251 hours
Recommended chimney diameter 3 in. or 4 in (see installation manual).
Flue outlet diameter 3 po. (76 mm)
Type of chimney ULC/ORD-C441, CAN/ULC S609
UL 641 (TYPE L)
Approved for alcove installation Yes
Approved for mobile home installation3Yes
Shipping weight (without option) 286 lb (130 kg)
Appliance weight (without option) 253 lb (115 kg)
Baffle material Stainless Steel
Type of door Simple, glass with cast iron frame
Type of glass Ceramic glass
Blower Included (176 CFM)
Noise level at 6 feet Min. 47 dBa (+/- 3 dBa)
Max. 60 dBa (+/- 3 dBa)
1 Grades of pellet fuel are determined by organizations such as Pellet Fuels Institute (PFI), ENplus and CANplus.
2 Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type, feed
rate, fuel level, and other variables. The recommended heated area for a given appliance is dened by the manufacturer as its capacity to maintain a
minimum acceptable temperature considering that the space conguration and the presence of heat distribution systems have a signicant impact
in making heat circulation optimum.
3 Mobile home (Canada) or manufactured home (USA): The US department of Housing and Urban Development describes “manufactured homes”
better known as “mobile homes” as followed; buildings built on xed wheels and those transported on temporary wheels/axles and set on a
permanent foundation. In Canada, a mobile home is a dwelling for which the manufacture and assembly of each component is completed or
substantially completed prior to being moved to a site for installation on a foundation and connection to service facilities and which conforms to the
CAN/CSA-Z240 MH standard.
Page 8 Operation Manual - 2500
ENGLISH
Certification Label
Since the information given on the certification label affixed to the stove always overrides the
information published in any other media (owner’s manual, catalogues, flyers, magazines or web sites),
it is important to refer to it in order to have a safe and compliant installation. In addition, important
information about the stove can be found (model, serial number, etc.). The certification label is located
on the inner side of the hopper lid of the stove.
Certification label - Page 1 Certification label - Page 2
Page 9Operation Manual - 2500
ENGLISH
FUEL
Recommended Pellets
Type: Wood pellet, premium grade or better, certified by PFI, Enplus or CANplus.
Size: Diameter between ¼" or 5/16" and not over 1" long. Longer or thicker pellets will affect the
constancy of pellet feed. The pellets length may vary from one lot to another, even if it comes from the
same manufacturer.
Short pellets Long pellets
Ash contents: Less than 1%. Ash contents more than 1% will increase maintenance frequency, create
combustion problems and will increase the stove emission.
Moisture content: Wet pellets will be very hard to ignite and will greatly affect the feeding process of the
stove. Using dry pellets will maintain the performance of your stove.
Note that the pellets quality may vary depending on the manufacturer. It can also vary from
one bag to another, even if it comes from the same manufacturer. It is recommended to
try several different manufacturers to find the one that best suits your use. Then, buy the
pellets in lots of several tons to ensure satisfaction.
Burning other types of pellets is prohibited. It violates the building codes for which the
stove has been approved and will void the warranty.
Storage
Pellets should remain in their original packaging until ready for use.
Pellets bags should be stored in a dry and well ventilated area, if possible. If they are to be stored
outside, remember that pellets bags are not water tight. It is best to keep the pallet wrapper as intact
as possible and cover it with a tarp.
Having a bag or two in the same room as the stove for refueling is a good idea. The minimum
clearances to combustible materials and the space required for refilling and ash removal needs to be
respected.
DO NOT STORE FUEL WITHIN STOVE MINIMUM CLEARANCES TO COMBUSTIBLE.
Page 10 Operation Manual - 2500
ENGLISH
STOVE CONTROLS
The stove, the pellet feeding system and the blowers are controlled by a control panel on the right-
hand side of the stove. The control panel buttons and display areas are as follows:
3
1
5
2
4
6
A
C
B
Stove controls
No Description
AControl panel display area.
BStove state display area.
CStove heating intensity display area, level 1 to 6.
1MODE: the «MODE» button is used to either turn off the appliance (OFF), turn it on in manual
operation (MANUAL) or in thermostatic operation (THERMOSTAT).
2RESET: The «RESET» button is used to reset the stove after the appearance of most of the
warning codes.
3AUX: The «AUX» button is used to adjust the convection air speed.
4AUGER: The «Auger» button is used to fill the auger with pellets.
5MINUS: The « - » button is used to reduce the pellet feeding rate thus reducing the heat
output of the stove.
6PLUS: The « + » button is used to increase the pellet feeding rate thus increasing the heat
output of the stove.
Page 11Operation Manual - 2500
ENGLISH
STOVE OPERATION
Before Operating the Stove
Make sure appliance and venting are installed as per manufacturer’s instructions;
Read and follow this operation manual;
Make sure all tools and accessories has been removed from inside the stove;
1
2
3
4
No Tools / Accessories
1Baffle
2Warning sheet
3Humidity absorbant
4Users manual
Tools and accessories located inside the stove
Make sure the baffle is installed as shown below:
Baffle final location in the stove
Make sure that the burn pot is in place properly and that there is enough pellets in the hopper.
The stove handle is removable. When the stove is in
operation, it must be stored behind the stove, as
shown in the «door handle location» figure.
Door handle location
Page 12 Operation Manual - 2500
ENGLISH
First Startup / Beginning of Season
Before starting the stove, the burn pot, the baffle and the access panels must be installed correctly.
The stove and hopper must have been emptied of all tools and accessories (see «Before operating
the stove»). In addition, all doors and covers must be closed and the vent system must be properly
installed and sealed.
Fill the hopper with pellets and press the «MODE» button once to start the stove in manual mode
(MANUAL) or twice to start the stove in thermostat mode (THERMOSTAT). For the first fire of the
season, or if the unit has run out of pellets, press the «AUGER» button first, then start the stove in
the desired mode. When the stove is turned on, it will automatically ignite. No fire starter is required.
If the stove does not light within 20 minutes of starting, the message «CODE L» will appear in the
display area. See the troubleshooting section for details.
During the first few fires, the stove will emit an odor and a small amount of fumes as the high temperature paint
cures or becomes seasoned to the metal. Maintaining smaller fires will minimize this. Avoid placing items on
stovetop during this period to avoid damaging the paint surface. Make sure the room is well-ventilated. Open
windows. Odors and fumes released during this process are unpleasant but they are not toxic.
Make two or three low intensity fires to initiate the paint hardening and the components
conditioning process. Then, make high intensity fires until the stove no longer smell of paint.
NEVER USE A GRATE OR OTHER MEANS TO SUPPORT THE FUEL. USE ONLY
THE APPROVED BURN POT FOR THIS STOVE AND DO NOT MODIFY IT.
Every Day Startup and Use
Before startup, make sure that the recommended maintenance has been performed according to the
schedule (see «Maintenance» section). Fill the hopper and press the «MODE» button once to start the
stove in manual mode (MANUAL) or twice to start the stove in thermostat mode (THERMOSTAT).
By pressing on the «+» or «-» buttons, it is possible to increase or decrease the feed rate, and thereby
the intensity level of the stove. Intensity levels change, from 1 to 6, can be visualized by the red light
in the heating intensity display area.
Running Out of Pellets
If the stove runs out of pellets, the fire will slowly go out. The convection blower will remain on until
the heat sensor reads 115 °F. The cooling cycle will take a few minutes before all other motors stop.
When this temperature is reached, the message «CODE E» will appear.
Restarting the stove will only be possible when all blowers are off (about 10 minutes after the error
message appears). Press «RESET» and fill the hopper. Press the «AUGER» button and then press the
«MODE» button on the home page to start the stove in the desired mode.
Refueling
When the stove is running, the hopper lid can be opened for 90 seconds to refill the hopper before
the stove stops. A beeping sound that will intensify every 30 seconds can be heard. After 90 seconds,
if the hopper lid is still open, the stove will stop and display the message «CODE d». For more
information, see the troubleshooting section for details. When the stove is stopped, there is no time
limit for filling the hopper. Note that opening the hopper lid will stop the auger from feeding the pellet stove.
THE HOPPER LID MUST BE CLOSED AT ALL TIMES EXCEPT WHEN REFULING.
Page 13Operation Manual - 2500
ENGLISH
DO NOT OVERFILL THE HOPPER.
Shutting Down Procedure
To turn the stove off, press the «MODE» button until the red light is in the OFF position. The cooling
cycle will take a few minutes. The blowers will continue to work while the stove is cooling down.
NEVER UNPLUG THE POWER CORD TO TURN OFF THE STOVE.
Signs of an Overheating Stove
Choosing a stove that is too small for the house in which it is installed may cause the stove to
overheat since it will have to operate at maximum setting for most of the time to achieve a comfortable
temperature. The life expectancy of the components and the stove will be reduced.
Under normal conditions, the flame must have a bright yellow color, be very active and stable. If the
flame becomes lazy, very high and orange, it is a sign of malfunction.
Usually, overheating issues are caused by too much restriction in the venting system, a blocked heat
exchanger, a lack of combustion air or a lack of maintenance.
If the stove is overheating, it will become very hot. If the stove gets too hot, it will shut itself down,
showing the «CODE H» message.
If this occurs once, wait for the stove to cool down and perform the weekly maintenance of the
stove suggested in the maintenance calendar. Carefully inspect the venting system. Have it swept,
if necessary. Press on the «MODE» and «RESET» buttons simultaneously for 3 seconds to reset the
stove.
If this occurs more than once, contacting the retailer may be helpful in order to receive some advice
for this code not to happen again.
After three occurence of an H code, the stove control will be locked and it will be impossible to reset
it and restart the stove. Before unlocking the stove control, perform the biannual maintenance
suggested in the maintenance calendar. Carefully inspect the venting system. Have it swept, if
necessary. When maintenance is done, press the following buttons, one at a time : «RESET», «MODE»,
«+», «-», then press on the «AUGER» for 5 seconds.
If any external part of the stove begins to glow red, the
stove is overheating. Immediately turn the stove off.
Do not unplug it and do not open the door.
Unpluging the stove will disable all the safety features
of the stove.
Page 14 Operation Manual - 2500
ENGLISH
Using a Thermostat
Using a thermostat will help maintain a constant temperature throughout the house. A Low voltage
thermostat (24 volts) is required. A fixed wall mount or hand held model can be used.
To use the stove in thermostat mode, press the «MODE» button until the «THERMOSTAT» position. is
reached. Then, select the intensity level using the «-» or «+» buttons. In thermostatic mode, the stove
will operate at the selected intensity level until the room temperature has reached the programmed
level on the thermostat.
Pilot Mode Selection
The factory setting of the pilot mode is «AUTO». To change it, press on the «-» and «MODE» buttons
simultaneously for 3 seconds. The selected mode will appear on the control panel display area.
Pilot AUTO (Intensity level 1)
When the thermostat stops calling for heat, the unit will remain at its lowest intensity level (#1) and will
shut down after 15 minutes, if there is no call for heat.
Pilot AUTO (Intensity level 2 to 6)
When the thermostat stops calling for heat, the unit automatically switch to its lowest intensity level
(#1) until the thermostat requires heat again. The stove will shut down after 45 minutes, if there is no
call for heat.
Pilot ON:
When the thermostat stops calling for heat, the unit automatically switch to its lowest intensity level
(#1) until the thermostat calls for heat again. The stove will never shut down, even if there is no call
for heat.
To avoid premature wear of the components, it is recommended to use the «Pilot ON» mode
during the coldest months and the «Pilot AUTO» mode during the warmest months.
Convection adjustments
Each intensity level has been programmed with an optimum convection speed. However, it is possible
to increase the convection air speed by pressing the «AUX» button. All intensity levels can be increased
at the exception of the intensity level 6, which is already at its maximum speed.
Page 15Operation Manual - 2500
ENGLISH
Air Intake Adjustments
It is possible to adjust the amount of combustion air entering the stove. Using the stove to the lowest
setting will reduce missed ignition, will ignite pellets faster and will reduce the blackening of the
window, when using high quality pellets. If you should find one bag of pellets harder to ignite and to
burn, opening the air control will help.
To open or close the manual air control, open the right decorative panel and locate the air intake. Push
down the tab and slide upwards to decrease the air supply and downwards to increase the air supply.
Page 16 Operation Manual - 2500
ENGLISH
MAINTENANCE
Maintenance Schedule
This schedule should be used as a reference only for a normal use of the stove. The cleaning frequency may
vary depending on the type of fuel used.
COMPONENTS WEEKLY
(±250 POUNDS)
TWICE A
YEAR
(± 1 TON)
YEARLY
(± 2 TONS)
Baffle Vacuum
Glass air wash system Vacuum
Burn Pot Scrape / Vacuum
Glass Clean
Ash drawer Empty / Vacuum
Combustion chamber Vacuum Brush / Vacuum
Heat exchanger Brush Scrape / Vacuum
Exhaust channels Vacuum
Exhaust blower Vacuum
Combustion blower Inspect
Convection blower Vacuum
Venting system Inspect / Sweep Clean and Sweep
Gaskets Inspect
Hopper Empty / Vacuum
Cleaning of the stove and its venting system is important, especially at the end of the heating
season to minimize corrosion during the summer months, caused by accumulated ash.
NEGLECTING THE RECOMMENDED CLEANING AND MAINTENANCE OF THE
APPLIANCE COULD RESULT IN POOR PERFORMANCE AND A SAFETY HAZARD.
DANGER
NEVER CLEAN WHEN HOT.
DANGER
DISCONNECT ALL POWER
BEFORE SERVICING THE
APPLIANCE.
Page 17Operation Manual - 2500
ENGLISH
Recommended tools
Universal brush Scraper
Steel brush Round brush + rod
Glass cleaner Ash vacuum
Ash removal
Ash drawer removal
DANGER
NEVER VACUUM THE ASHES WHEN THEY ARE HOT. THE ASHES MUST BE
COOLED BEFORE SERVICING.
Page 18 Operation Manual - 2500
ENGLISH
The ashes should be placed in a metal container with a tight lid. The container should be placed
on a non-combustible surface, away from any material that may catch fire. If the ash is to be
buried or locally dispersed, it should be kept in the closed container until it is completely cooled.
The use of a domestic, central or commercial vacuum cleaner to maintain the stove is not
recommended. The use of an ash vacuum cleaner is strongly recommended.
Burn pot
Remove and empty burn pot Scrape, if necessary
Combustion Chamber
Clean the combustion chamber by vaccuming the cooled ashes. When necessary, brush the walls and
vacuum the ashes afterwards.
You can also push the ashes into the ash drawer through the opening at the bottom of the firebox. In
this case alone, the ashes do not have to be cold.
Remove ash plug to sweep ashes in the ash drawer
Page 19Operation Manual - 2500
ENGLISH
Glass Maintenance
Vacuum ashes accumulated in the airwash system of the glass. This allows optimum air flow and
prevents the window from sooting up.
Clean door glass when necessary. The use of a stove glass cleaner is recommended. Regular household
glass cleaners will not remove creosote properly.
Vacuum ashes acumulated in the airwash system
NEVER USE ABRASIVE CLEANERS ON THE GLASS OR ON ANY PLATED
PARTS.
DO NOT CLEAN THE GLASS WHEN IT IS HOT.
DO NOT FORCE, STRIKE, SLAM OR ANY OTHER BEHAVIOR THAT COULD
FRAGILIZE THE GLASS DOOR.
DO NOT USE THE STOVE IF THE GLASS IS MISSING, CRACKED OR BROKEN.
Replacing the Glass
1. Remove the door and place it on a table,
face-down on something soft like a cushion
of rags or piece of carpet
2. Remove the 10 screws holding the door glass
retainers and carefully remove any loose
pieces of glass from the doorframe. Dispose
of all broken glass properly. A broken glass
should be replaced with a 13 7/8" x 8 5/8"
ceramic glass, 5 mm thick.
ALWAYS WEAR GLOVES WHEN
HANDLING BROKEN GLASS.
Glass retainer removal
Page 20 Operation Manual - 2500
ENGLISH
3. Remove the stove ciment in the door corners (see dark spots in the figure below). When done,
reinstall the new glass.
Stove cement location Reinstalling the new glass
5. Put stove cement in the door corners, as shown on the image above.
6. Reinstall the glass door retainers making sure the stove cement is pressed down by the retainers.
Push the retainers towards the door frame to make sure there is no gag between the retainers
and the door frame and screw them in place. Do not over-tighten the screws as this will make the
glass crack under strong heat.
Push the retainers towards the door frame
8. Reinstall the door and wait 24 hours before using the stove again.
The replacement glass must be purchased only from an authorized dealer. Tempered glass or ordinary glass is
not suitable for high temperatures.
When changing the glass, make sure that the glass gaskets are in the same place as the originals to maintain
proper operation of the airwash system of the glass.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Osburn OP00025 Guide d'installation

Catégorie
Poêles
Taper
Guide d'installation

dans d''autres langues