ENGLISH
EVERPURE H-Series Water Filtration Systems • 13
H300NXT CARTRIDGE PART NO. EV927441,
EV927446
IMPORTANT NOTICE: Read this Everpure Performance Data
Sheet and compare the capabilities of this unit with your
actual water treatment needs. It is recommended that, before
purchasing a water treatment unit, you have your water tested
to determine your actual treatment needs.
FEATURES
• Finely polishes treated water to premium quality for
drinking and cooking.
• NSF/ANSI Standard 53 certied to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
• Reduces dirt, rust and other particulates sulfides (oxidized iron
and manganese – As tested by Everpure).
• Controls even extreme levels of common "off" taste and odors,
including those which are earthy, moldy, and fishy.
• Reduces lead to below the Federal Action Level of 15 ppb.
• Effectively reduces Volatile Organic Chemicals (VOCs),
including Trihalomethanes (THMs).
• Effectively reduces methyl tertiary-butyl ether (MTBE).
• Reduces particles as small as 0.5 micron in size by
mechanical means.
H-300-NXT Performance Data
This system has been tested according to NSF/ANSI 42, 53,
and 401 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specified
in NSF/ANSI 42, 53, and 401.
NOTE: Spent adsorption media will not be regenerated and
used. If adsorption media is affected by chlorine, water supply
should be treated to remove chlorine prior to entering filter.
PERFORMANCE DATA SHEET
H300NXT DRINKING WATER SYSTEM
OPERATING SPECIFICATIONS
• Capacity: 300 gallons (1,136L)
• Pressure Requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
• Temperature: 35-100°F (2°-38°C)
• Flow Rate: 0.5 gpm (1.9 Lpm
PERFORMANCE DATA SHEET REDUCTION CLAIMS FOR
ORGANIC CHEMICALS INCLUDED BY SURROGATE TESTING
ENGLISH
EVERPURE H-Series Water Filtration Systems • 13
IMPORTANT NOTICE:
Read this Everpure* Performance Data Sheet
and compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
• Finely polishes treated water to premium quality for drinking and cooking.
• Reduces chlorine taste and odor.
• Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and suldes - As tested by Pentair.
• NSF/ANSI Standard 53 certied to reduce c ysts such as Cryptosporidium
and Giardia by mechanical means.
• Controls even extreme levels of common “o” tastes and odors, including
those which are earthy, moldy and shy.
• Reduces lead.
• Eectively reduces Volatile Organic Chemicals (VOCs).
• Reduces particles as small as 0.5 micron in size by mechanical means.
• NSF/ANSI Standard 401 certied for the reduction of the incidental
contaminants/emerging compounds listed in the performance data sheet.
ERFORMANCE ATA
This system has been tested ac cording to NSF/ANSI 42, 53 and 401
for the reduction of the substances listed bel ow. The concentration of
the indicated substances in water entering the s ystem was reduced to
a concentration less than or equal to the permissible limit for water
leaving the s ystem, as specied in NSF/ANSI 42, 53 and 401.
Substance
Influent
Challenge
Concentration
Max.
Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Eects
Chlorine 2.0 mg/L ± 10% ≥ 50% 86.8%
Particulate, Class I
particles 0.5 to <1 µm
at least 10,000
particles/mL ≥ 85% 98.8%
Standard 53—Health Eects
Cyst Minimum 50,000/L 99.95% 99.99 99.99%
Lead 6.5 0.15 mg/L ± 10% 0.005 mg/L 99.3% 99.3%
Lead 8.5 0.15 mg/L ± 10% 0.005 mg/L 98.7% 99.3%
Chloroform 0.300 mg/L 0.015 mg/L 95.8% 98.9%
(VOC surrogate chemical)
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
Standard 401—Emerging Contaminants
†
Phenytoin 200 ± 20% ng/L 0.000030 mg/L >96.3%
Ibuprofen 400 ± 20% ng/L 0.000060 mg/L >95.8%
Naproxen 140 ± 20% ng/L 0.000020 mg/L >96.8%
Estrone 140 ± 20% ng/L 0.000020 mg/L >97.2%
Bisphenol A (BPA) 2,000 ± 20% ng/L 0.000300 mg/L >99.2%
Nonylphenol 1,400 ± 20% ng/L 0.000200 mg/L >97.1%
†
NSF/ANSI Standard 401 have been deemed as “incidental contaminants/emerging compounds”.
Incidental contaminants are those compounds that have been detected in drinking water supplies at
trace levels. While occurring at only trace levels, these compounds can aect the public acceptance/
perception of drinking water quality.
OPERATING SPECIFICATIONS
• Capacity: 300 gallons (1,136L)
• Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
• Temperature: 35-100°F (2-38°C)
• Flow Rate: 0.5 gpm (1.9 Lpm)
Performance Data Sheet Reduction Claims
for Organic Chemicals Included by Surrogate Testing
Substance Inuent Challenge
Concentration mg/L
Maximum Permissible Product
Water Concentration mg/L
alachlor 0.050 0.001
atrazine 0.100 0.003
benzene 0.081 0.001
carbofuran 0.190 0.001
carbon tetrachloride 0.078 0.0018
chlorobenzene 0.077 0.001
chloropicrin 0.015 0.0002
2,4-D 0.110 0.0017
dibromochloropropane (DBCP) 0.052 0.00002
o-dichlorobenzene 0.080 0.001
p-dichlorobenzene 0.040 0.001
1,2-dichloroethane 0.088 0.0048
1,1-dichloroethylene 0.083 0.001
cis-1,2-dichloroethylene 0.170 0.0005
trans-1,2-dichloroethylene 0.086 0.001
1,2-dichloropropane 0.080 0.001
cis-1,3-dichloropropylene 0.079 0.001
dinoseb 0.170 0.0002
endrin 0.053 0.00059
ethylbenzene 0.088 0.001
ethylene dibromide (EDB) 0.044 0.00002
haloacetonitriles (HAN):
bromochloroacentonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
0.0072
0.0082
0.0001
0.0003
heptachlor 0.080 0.0004
heptachlor epoxide 0.0107 0.0002
hexachlorobutadiene 0.044 0.001
hexachlorocyclopentadiene 0.060 0.000002
lindane 0.055 0.00001
methoxychlor 0.050 0.0001
pentachlorophenol 0.096 0.001
simazine 0.120 0.004
styrene 0.150 0.0005
1,1,2,2-tetrachloroethane 0.081 0.001
tetrachloroethylene 0.081 0.001
toluene 0.078 0.001
2,4,5-TP(silvex) 0.270 0.0016
tribromoacetic acid 0.042 0.001
1,2,4-trichlorobenzene 0.160 0.0005
1,1,1-trichloroethane 0.084 0.0046
1,1,2-trichlor oethane 0.150 0.0005
trichl oroethylene 0.180 0.001
trihalomethanes (includes):
chloroform (surrogate
chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.300 0.015
xylenes (total) 0.070 0.001
H-300-NXT Cartridge - Part Nos. EV927441, EV927446
H-300-NXT DRINKING WATER SYSTEM
EPA Est. 002623-IL-002
The H-300-NXT is Tested and Certied by NSF
International against CSA B483.1 and NSF/ANSI
42, 53, and 401 for the claims specied on the
Performance Data Sheet.
C US
PER FORM ANCE DATA SHEE T
NOTE:
Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering lter.
ENGLISH
EVERPURE H-Series Water Filtration Systems • 13
IMPORTANT NOTICE:
Read this Everpure* Performance Data Sheet
and compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
• Finely polishes treated water to premium quality for drinking and cooking.
• Reduces chlorine taste and odor.
• Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and suldes - As tested by Pentair.
• NSF/ANSI Standard 53 certied to reduce c ysts such as Cryptosporidium
and Giardia by mechanical means.
• Controls even extreme levels of common “o” tastes and odors, including
those which are earthy, moldy and shy.
• Reduces lead.
• Eectively reduces Volatile Organic Chemicals (VOCs).
• Reduces particles as small as 0.5 micron in size by mechanical means.
• NSF/ANSI Standard 401 certied for the reduction of the incidental
contaminants/emerging compounds listed in the performance data sheet.
ERFORMANCE ATA
This system has been tested ac cording to NSF/ANSI 42, 53 and 401
for the reduction of the substances listed bel ow. The concentration of
the indicated substances in water entering the s ystem was reduced to
a concentration less than or equal to the permissible limit for water
leaving the s ystem, as specied in NSF/ANSI 42, 53 and 401.
Substance
Influent
Challenge
Concentration
Max.
Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Eects
Chlorine 2.0 mg/L ± 10% ≥ 50% 86.8%
Particulate, Class I
particles 0.5 to <1 µm
at least 10,000
particles/mL ≥ 85% 98.8%
Standard 53—Health Eects
Cyst Minimum 50,000/L 99.95% 99.99 99.99%
Lead 6.5 0.15 mg/L ± 10% 0.005 mg/L 99.3% 99.3%
Lead 8.5 0.15 mg/L ± 10% 0.005 mg/L 98.7% 99.3%
Chloroform 0.300 mg/L 0.015 mg/L 95.8% 98.9%
(VOC surrogate chemical)
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
Standard 401—Emerging Contaminants
†
Phenytoin 200 ± 20% ng/L 0.000030 mg/L >96.3%
Ibuprofen 400 ± 20% ng/L 0.000060 mg/L >95.8%
Naproxen 140 ± 20% ng/L 0.000020 mg/L >96.8%
Estrone 140 ± 20% ng/L 0.000020 mg/L >97.2%
Bisphenol A (BPA) 2,000 ± 20% ng/L 0.000300 mg/L >99.2%
Nonylphenol 1,400 ± 20% ng/L 0.000200 mg/L >97.1%
†
NSF/ANSI Standard 401 have been deemed as “incidental contaminants/emerging compounds”.
Incidental contaminants are those compounds that have been detected in drinking water supplies at
trace levels. While occurring at only trace levels, these compounds can aect the public acceptance/
perception of drinking water quality.
OPERATING SPECIFICATIONS
• Capacity: 300 gallons (1,136L)
• Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
• Temperature: 35-100°F (2-38°C)
• Flow Rate: 0.5 gpm (1.9 Lpm)
Performance Data Sheet Reduction Claims
for Organic Chemicals Included by Surrogate Testing
Substance Inuent Challenge
Concentration mg/L
Maximum Permissible Product
Water Concentration mg/L
alachlor 0.050 0.001
atrazine 0.100 0.003
benzene 0.081 0.001
carbofuran 0.190 0.001
carbon tetrachloride 0.078 0.0018
chlorobenzene 0.077 0.001
chloropicrin 0.015 0.0002
2,4-D 0.110 0.0017
dibromochloropropane (DBCP) 0.052 0.00002
o-dichlorobenzene 0.080 0.001
p-dichlorobenzene 0.040 0.001
1,2-dichloroethane 0.088 0.0048
1,1-dichloroethylene 0.083 0.001
cis-1,2-dichloroethylene 0.170 0.0005
trans-1,2-dichloroethylene 0.086 0.001
1,2-dichloropropane 0.080 0.001
cis-1,3-dichloropropylene 0.079 0.001
dinoseb 0.170 0.0002
endrin 0.053 0.00059
ethylbenzene 0.088 0.001
ethylene dibromide (EDB) 0.044 0.00002
haloacetonitriles (HAN):
bromochloroacentonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
0.0072
0.0082
0.0001
0.0003
heptachlor 0.080 0.0004
heptachlor epoxide 0.0107 0.0002
hexachlorobutadiene 0.044 0.001
hexachlorocyclopentadiene 0.060 0.000002
lindane 0.055 0.00001
methoxychlor 0.050 0.0001
pentachlorophenol 0.096 0.001
simazine 0.120 0.004
styrene 0.150 0.0005
1,1,2,2-tetrachloroethane 0.081 0.001
tetrachloroethylene 0.081 0.001
toluene 0.078 0.001
2,4,5-TP(silvex) 0.270 0.0016
tribromoacetic acid 0.042 0.001
1,2,4-trichlorobenzene 0.160 0.0005
1,1,1-trichloroethane 0.084 0.0046
1,1,2-trichlor oethane 0.150 0.0005
trichl oroethylene 0.180 0.001
trihalomethanes (includes):
chloroform (surrogate
chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.300 0.015
xylenes (total) 0.070 0.001
H-300-NXT Cartridge - Part Nos. EV927441, EV927446
H-300-NXT DRINKING WATER SYSTEM
EPA Est. 002623-IL-002
The H-300-NXT is Tested and Certied by NSF
International against CSA B483.1 and NSF/ANSI
42, 53, and 401 for the claims specied on the
Performance Data Sheet.
C US
PER FORM ANCE DATA SHEE T
NOTE: Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering lter.
H-104 Cartridge - Part No. EV9612-11, EV9612-16
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
dna gniknird rof yt i lauq muimerp ot retaw detaert sehsi lop yleniF •
cooking.
• Reduces chlorine taste and odor.
, nor i dez i d i xo sa hcus se t a l uc i t rap reht o dna t sur , t r i d secudeR •
manganese, and sulfides.
• NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
• Reduces common earthy, moldy, fishy tastes and odors.
• Reduces lead to below the Federal Action Level.
• Reduces particles as small as 0.5 micron in size by mechanical
means.
H-104 PERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ° 50% 87.8%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL ° 85% 98.8%
Standard 53—Health Effects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.010 mg/L 99.3% 99.3%
Lead 6.5 0.15 mg/L ± 10% 0.010 mg/L 98.7% 99.3%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
OPERATING SPECIFICATIONS
• Capacity: 1,000 gallons (3,780L)
• Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
• Temperature: 35-100°F (2°-38°C)
• Flow Rate: 0.5 gpm (1.9 Lpm)
EPA Est. 002623-IL-002
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
gnidulcni )mc 15 x 31 x 31( .ni 02 x 5 x 5 :deriuqer ecapS •
2½ inches of clear space under unit for cartridge change.
• Install vertically with cartridge hanging down.
• Use minimum length of tubing possible.
• Flush new cartridge at full flow for three minutes to purge air.
semoceb wo l f nehw r o , dehcae r s i y t i capac nehw segd i r t r ac eca l peR •
too slow, but at least annually.
SPECIAL NOTICES
• Installation instructions, parts and service availability, and standard
warranty are included with the product.
• This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges. Suggested retail $122.99.
• Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
• The contaminants or other substances removed or reduced by this
water treatment system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
• Tested under standard laboratory conditions, actual performance
may vary.
• Spent adsorption media will not be regenerated and used.
• If adsorption media is affected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
System Tested and Certified by NSF International against
CSA B483.1 and NSF/ANSI 42 and 53 for the claims
specified on the Performance Data Sheet.
H-104 DRINKING WATER SYSTEMS
C US
The H-300-NXT is Tested and Certified by NSF
International against CSA B483.1 and NSF/
ANSI 42 and 53 for the claims specified on the
Performance Data Sheet.
EPA Est. No. 002623-IL-002