Toto CP Guide d'installation

Taper
Guide d'installation
Warranty Registration and Inquiry
For product warranty registration, TOTO U.S.A. Inc. recommends online warranty registration. Please visit
our web site http://www.totousa.com. If you have questions regarding warranty policy or coverage, please
contact TOTO U.S.A. Inc., Customer Service Department, 1155 Southern Road, Morrow, GA 30260
(888) 295-8134 or (678) 466-1300 when calling from outside of U.S.A.
Installation and Owner’s Manual
Manual de instalación y del propietario
Manuel d’installation et guide d’utilisation
Manual do Proprietário e de Instalação
TLK03001G TLK01101G
TLK01102G TLK01103G
TLK01106G TLK01107G
TLK01401G TLK01403G
Automatic Soap Dispenser
Dispensador de jabón automático
Distributeur automatique de savon
Distribuidor automático de sabonete líquido
2
THANK YOU FOR CHOOSING TOTO! ............................................................................................2
WARNINGS.......................................................................................................................................2
BEFORE INSTALLATION .................................................................................................................2
INCLUDED PARTS ...........................................................................................................................3
INSTALLATION PROCEDURE.........................................................................................................5
TESTING.........................................................................................................................................16
HOW TO USE .................................................................................................................................17
REFILLING THE TANK ...................................................................................................................18
MODE ADJUSTMENT.....................................................................................................................19
CARE AND CLEANING ..................................................................................................................20
PERIODIC MAINTENANCE............................................................................................................21
LONG-TERM NON-USE .................................................................................................................25
TROUBLESHOOTING ....................................................................................................................25
SPECIFICATIONS...........................................................................................................................26
THREE YEAR LIMITED WARRANTY.............................................................................................28
ROUGH - IN DIMENSIONS...........................................................................................................110
The mission of TOTO is to provide the world with healthy, hygienic and more comfortable lifestyles.
We design every product with the balance of form and function as a guiding principle.
Congratulations on your choice.
TABLE OF CONTENTS
THANK YOU FOR CHOOSING TOTO!
Please read and adhere to the following notes. Failure to do so could result in personal injury
and/or property damage.
WARNINGS
BEFORE INSTALLATION
No person other than a service engineer should disassemble, repair or modify this
dispenser, unless it is specifically described in this manual. Failure to do so may result in
electric shock or product malfunction.
Do not use this dispenser in a humid location where condensation may collect on the
surface, especially in a sauna or steam room.
Do not strike or kick the dispenser or controller box, as this may damage the unit or cause a leak.
Do not use this dispenser if the room temperature drops below freezing.
Make sure the power cord does not come in contact with the hot water supply line.
Avoid placing any objects within the detection range of the infrared sensor.
Use only TOTO approved liquid soap to avoid invalidation of warranty.
Make sure the electrical outlet is in a position where it will not get wet during use.
Read these instructions carefully to ensure proper installation.
TOTO reserves the right to update product design without notice.
Check to make sure you have the parts indicated on the following page.
ENGLISH
2
THANK YOU FOR CHOOSING TOTO! ............................................................................................2
WARNINGS.......................................................................................................................................2
BEFORE INSTALLATION .................................................................................................................2
INCLUDED PARTS ...........................................................................................................................3
INSTALLATION PROCEDURE.........................................................................................................5
TESTING.........................................................................................................................................16
HOW TO USE .................................................................................................................................17
REFILLING THE TANK ...................................................................................................................18
MODE ADJUSTMENT.....................................................................................................................19
CARE AND CLEANING ..................................................................................................................20
PERIODIC MAINTENANCE............................................................................................................21
LONG-TERM NON-USE .................................................................................................................25
TROUBLESHOOTING ....................................................................................................................25
SPECIFICATIONS...........................................................................................................................26
THREE YEAR LIMITED WARRANTY.............................................................................................28
ROUGH - IN DIMENSIONS...........................................................................................................110
The mission of TOTO is to provide the world with healthy, hygienic and more comfortable lifestyles.
We design every product with the balance of form and function as a guiding principle.
Congratulations on your choice.
TABLE OF CONTENTS
THANK YOU FOR CHOOSING TOTO!
Please read and adhere to the following notes. Failure to do so could result in personal injury
and/or property damage.
WARNINGS
BEFORE INSTALLATION
No person other than a service engineer should disassemble, repair or modify this
dispenser, unless it is specifically described in this manual. Failure to do so may result in
electric shock or product malfunction.
Do not use this dispenser in a humid location where condensation may collect on the
surface, especially in a sauna or steam room.
Do not strike or kick the dispenser or controller box, as this may damage the unit or cause a leak.
Do not use this dispenser if the room temperature drops below freezing.
Make sure the power cord does not come in contact with the hot water supply line.
Avoid placing any objects within the detection range of the infrared sensor.
Use only TOTO approved liquid soap to avoid invalidation of warranty.
Make sure the electrical outlet is in a position where it will not get wet during use.
Read these instructions carefully to ensure proper installation.
TOTO reserves the right to update product design without notice.
Check to make sure you have the parts indicated on the following page.
ENGLISH
3
INCLUDED PARTS
*1L tank (Special Order)
3L tank
Bracket set
(for 3L tank only)
ControllerSpout Assembly
(TLK03001G)
Screw
(Φ 5.1 x 32)
Screw
(Φ 5.1 x 32)
Mounting
bracket
Supply port cap
Supply port cap
Bracket
Hose 7.1” (18 cm)
Bundling
band
Round-head screw
(Φ 5.1 x 32)
Hose clamp: 2
Countersunk
tapping screw
(Φ 4 x 10)
Anchoring plate
Bracket
Decorative
screw
Hose 6.6’ (2 m)
(Single type: 1, Double type: 2,
Triple type: 3)
Hose clamp
(Single type: 2, Double type: 4,
Triple type: 6)
ENGLISH
4
INCLUDED PARTS
(Continued)
TLK01101U TLK01102U
TLK01103U
Hose Unit (TLK01403U)
I-shaped nippleConnecting hose 16.4’ (5m) Hose clamps (1)
Sub-Tank Unit (TLK01401U)
Soap Intake
Sub-Tank Y-shaped nipple
Connecting hose 16.4’ (5m)
Hose clamps (6)
Special Order
TLK01106U
TLK01107U
ENGLISH
4
INCLUDED PARTS
(Continued)
TLK01101U TLK01102U
TLK01103U
Hose Unit (TLK01403U)
I-shaped nippleConnecting hose 16.4’ (5m) Hose clamps (1)
Sub-Tank Unit (TLK01401U)
Soap Intake
Sub-Tank Y-shaped nipple
Connecting hose 16.4’ (5m)
Hose clamps (6)
Special Order
TLK01106U
TLK01107U
ENGLISH
5
1. Make sure to leave at least 4-3/4" (120 mm)
of space between the soap dispenser and
the faucet to prevent accidental activation.
2. Leave 3-1/8" (80 mm) of space maximum
from the inside edge of the sink to the spout
installation hole to ensure that any residual
soap drips from the dispenser spout into the
sink bowl.
INSTALLATION PROCEDURE - Positioning
Positioning the Dispenser
Positioning the Tank
Sink
Auto Soap Dispenser
Faucet
(2)
The distance from the
soap dispenser to the
edge of the sink to be
3-1/8" (80 mm) maximum
Hole for installing
the dispenser
[1"1-3/32" (2528 mm)
in diameter]
(1) Space between the dispenser
and the faucet to be
4-3/4" (120 mm) minimum
Install the tank within 31.5 inch from the upper face of the counter. It also should not exceed the
height of the upper end of the controller.
It cannot be installed on the counter or on the lower level.
If it is installed beyond this range, the following troubles may occur. Less water spouts and the
soap does not foam.
The length of the hose connected to the spout is 6.0 ft. Install the controller so that the hose can
be connected to the controller.
Spouts
Controller
Less than 55'' (1400 mm)
(Height of controller:
14'' (350 mm))Less than 59'' (1500 mm)
(Unit: Inch)
* The dimensions in the figure are limited to when
the tank is installed on the left end.
If actual dimensions exceed those in the figure,
cords and hoses may not reach.
Tank
* For a spout-to-spout distance
of 25.6'' (650 mm)
Less than 31.5''
(800 mm)
Controller installable range
(* 59'' (1500 mm))
ENGLISH
6
1. Insert the dispenser into the installation
holes in the counter (or the sink).
2. Disassemble screw and washer with the
hex nuts.
INSTALLATION PROCEDURE - Spout
INSTALLATION PROCEDURE - Controller
Marking of the positions of the screw holes for the anchoring plate.
Decide the anchoring position of the controller and mark the positions of screw holes on the wall by
referring to the dimensional drawing.
Reference
anchoring screw
1. Drill a rough hole at the screw hole position
and drive in the curl plug (procure in the field).
2. Anchor the bottom anchoring plate to the
controller with one countersunk tapping screw.
Installing the controller on a tiled or concrete wall
[ 3L Tank Type ]
Controller (Back side)
Anchoring plate
Countersunk
tapping screw
(Φ 4 x 10)
Anchoring plate
Countersunk tapping screw
(Φ 4 x 10)
Top side Bottom side
Reference
anchoring screw
(Unit: Inch)
[ 1L Tank Type ]
Dispenser
Packing
Sensor cord
Washer
Hex nut
Air hose (blue)
Liquid soap hose
(clear)
* Procure a curl plug that matches the screw
(Φ 5.1 x 32).
Caution
Make sure that the cords and tubes do not get
crimped.
Caution
Do not tighten the screws with an electric
screwdriver.
These should be tightened manually.
Pay attention not to confuse the top side and
the bottom side of the anchoring plate.
Anchor
3.7''
5.9''
1.9''
2.8''
5.9''
0.8''
1.9''
3.7''
5.4''
ENGLISH
6
1. Insert the dispenser into the installation
holes in the counter (or the sink).
2. Disassemble screw and washer with the
hex nuts.
INSTALLATION PROCEDURE - Spout
INSTALLATION PROCEDURE - Controller
Marking of the positions of the screw holes for the anchoring plate.
Decide the anchoring position of the controller and mark the positions of screw holes on the wall by
referring to the dimensional drawing.
Reference
anchoring screw
1. Drill a rough hole at the screw hole position
and drive in the curl plug (procure in the field).
2. Anchor the bottom anchoring plate to the
controller with one countersunk tapping screw.
Installing the controller on a tiled or concrete wall
[ 3L Tank Type ]
Controller (Back side)
Anchoring plate
Countersunk
tapping screw
(Φ 4 x 10)
Anchoring plate
Countersunk tapping screw
(Φ 4 x 10)
Top side Bottom side
Reference
anchoring screw
(Unit: Inch)
[ 1L Tank Type ]
Dispenser
Packing
Sensor cord
Washer
Hex nut
Air hose (blue)
Liquid soap hose
(clear)
* Procure a curl plug that matches the screw
(Φ 5.1 x 32).
Caution
Make sure that the cords and tubes do not get
crimped.
Caution
Do not tighten the screws with an electric
screwdriver.
These should be tightened manually.
Pay attention not to confuse the top side and
the bottom side of the anchoring plate.
Anchor
3.7''
5.9''
1.9''
2.8''
5.9''
0.8''
1.9''
3.7''
5.4''
ENGLISH
7
3. Position and anchor the bracket with two
screws.
Confirm that the wooden wall has a structure that
can sustain the weight (4.41lb) of the controller
(Triple type). (In the case of dry wall, in order to
hold the controller, make sure the plywood base
is more than 0.5 inch thick.) Anchor the mounting
bracket with two screws and anchor the anchoring
plate with one screw. Reinforce the wall structure
sufficiently as needed.
4. Hang the controller on the mounting bracket
and anchor the bottom anchoring plate with
one screw.
INSTALLATION PROCEDURE - Controller
(Continued)
Dimensions
(Unit: Inch)
[ 3L Tank Type ] [ 1L Tank Type ]
Controller
Caution
Install the unit body horizontally.
Pay attention not to pinch of the electric cord or
contact it with edges.
*
Sandwich the grounding wire with the
mounting bracket and anchor them with screw.
Installing the controller on a wooden
wall or dry wall
Mounting bracket
Screws
Screw
Anchoring plate
1.0'' 1.0''3.7''
5.9''
0.4''
1.9''
2.8'' 2.8''
5.4''1.3''
4.6''
5.9''
1.9''
1.7'' 2.8''
0.8''
4.5'' 3.7'' 1.0''
5.4''
0.4''
5.4''
ENGLISH
8
1. Anchor the tank and the brackets with the
decorative screws that should be tightened by
hand.
Using the bracket to anchor the tank on the floor.
2. Install the tank on the floor with the screw.
1. Anchor the bracket with the attached
round-head screw.
2. Pass the constricted part of the tank
between the bracket and insert it the full
depth.
3. Insert the tank in the slit on the bottom
surface of the bracket and pass it through
the two holes.
INSTALLATION PROCEDURE - Tank
[ 3L Tank Type ]
[ 1L Tank Type ]
Note
If the floor is made of concrete, embed the curl
plugs first.
4. Attaching the bundling band.
* The bundling band serves to prevent the
tank from falling off if the tank collides
with something.
If the tank is installed behind a wall, etc., it
is not necessary to attach the bundling
band.
Bracket 1. Decorative screw
Tank
2. Screw
Two round-head
screws
(Φ 5.1 x 32)
Bracket
Bracket
Wall surface
2. Insert it
the full depth.
Constricted part
Hole
Slit on the bottom of
the bracket
4. Bundling band
3.
ENGLISH
8
1. Anchor the tank and the brackets with the
decorative screws that should be tightened by
hand.
Using the bracket to anchor the tank on the floor.
2. Install the tank on the floor with the screw.
1. Anchor the bracket with the attached
round-head screw.
2. Pass the constricted part of the tank
between the bracket and insert it the full
depth.
3. Insert the tank in the slit on the bottom
surface of the bracket and pass it through
the two holes.
INSTALLATION PROCEDURE - Tank
[ 3L Tank Type ]
[ 1L Tank Type ]
Note
If the floor is made of concrete, embed the curl
plugs first.
4. Attaching the bundling band.
* The bundling band serves to prevent the
tank from falling off if the tank collides
with something.
If the tank is installed behind a wall, etc., it
is not necessary to attach the bundling
band.
Bracket 1. Decorative screw
Tank
2. Screw
Two round-head
screws
(Φ 5.1 x 32)
Bracket
Bracket
Wall surface
2. Insert it
the full depth.
Constricted part
Hole
Slit on the bottom of
the bracket
4. Bundling band
3.
ENGLISH
9
2. Insert the hose fully into the controller and
put the hose clamp on the projection of the
joint to anchor the hose securely.
INSTALLATION PROCEDURE - Connecting Hoses and Cords
[ Tank side ]
[ Controller side ]
3L TANK 1L TANK
* Connect the single type to only.
(The sensor does not work in any other
position.)
* Connect the double type to and .
( does not work.)
Hose
Hose clamp
Projection of joint
Liquid soap hose (clear)
Connect it to the tank.
Liquid soap hose (clear)
Connect it to the spout.
Air hose (blue)
Connect it to the spout.
Caution
Using a cutter, etc., cut the hoses so that the
cut surface becomes vertical.
1. Cut the hoses to an appropriate length that
reaches to the connected part.
(Between the spouts and the controller)
(Between the controller and the tank)
Caution
Connect the hoses and sensors in the
predetermined pairs. 
When inserting the hoses, pay attention not
to apply strong force to the joint of the tank.
Pay attention not to bend the hoses.
Hose Connections
Connect the hoses
and sensors in the
predetermined pairs.
ENGLISH
10
Connector (white) for sensor only
Connectors (white) and (yellow) for sensor
Connectors (white), (yellow) and (blue)
for sensor
INSTALLATION PROCEDURE - Connecting Hoses and Cords
(Continued)
[ Sensor cord ] [ Float switch cord ]
Bundling clamp
Controller
Tank
Bundling clamp
Connect in one place.
Connect in two places.
Connect in three places.
Caution
All connectors of the sensors connected to the
spout are white.
The colors of the connectors arranged in the
controller are white, yellow and blue.
Different colors may be connected.
Remove the cover of the controller and
connect the sensor connector to the float
switch connector.
Connect the sensor connector and the hose
in the prescribed positions.
Connector Connections
Using bundling clamps, stow and bundle the cords.
Bundling of Cords
Side face (View of wiring)
For single installation
For double installation
For triple installation
Connect the hoses
and the sensors in
predetermined
pairs.
White Yellow Blue
Socket (Sensors)
Float switch
Connector (Sensors, white)
Wiring Image
ENGLISH
10
Connector (white) for sensor only
Connectors (white) and (yellow) for sensor
Connectors (white), (yellow) and (blue)
for sensor
INSTALLATION PROCEDURE - Connecting Hoses and Cords
(Continued)
[ Sensor cord ] [ Float switch cord ]
Bundling clamp
Controller
Tank
Bundling clamp
Connect in one place.
Connect in two places.
Connect in three places.
Caution
All connectors of the sensors connected to the
spout are white.
The colors of the connectors arranged in the
controller are white, yellow and blue.
Different colors may be connected.
Remove the cover of the controller and
connect the sensor connector to the float
switch connector.
Connect the sensor connector and the hose
in the prescribed positions.
Connector Connections
Using bundling clamps, stow and bundle the cords.
Bundling of Cords
Side face (View of wiring)
For single installation
For double installation
For triple installation
Connect the hoses
and the sensors in
predetermined
pairs.
White Yellow Blue
Socket (Sensors)
Float switch
Connector (Sensors, white)
Wiring Image
ENGLISH
INSTALLATION PROCEDURE - FILLING liquid soap
11
1. Remove cap on the tank.
Open
2. Slowly pour liquid soap into the holding tank.
Please keep an eye on the level as you pour the
liquid soap in slowly so that it doesn't become
foamy. Please pour the liquid soap through the
build-in filter.
Please make sure that the cap is securely in place
after filling the tank.
3. Firmly close the cap on the tank.
Close
ENGLISH
12
Installation Completion Drawing
Bundling of cords
L=6ft (1800mm)
L=6.6ft (2000mm)
L=4.6ft (1400mm)
ENGLISH
12
Installation Completion Drawing
Bundling of cords
L=6ft (1800mm)
L=6.6ft (2000mm)
L=4.6ft (1400mm)
ENGLISH
13
1. Connect the hose to the sub-tank.
* Use the connection hose for connecting
the tank and cut to the desired length to fit
between the sub-tank and the tank.
3. Connect the air deflation hose.
4. Attach the elbow to the front end of the air
deflation hose and attach it to the wall with
the hose tie and wood screw.
* Do not block the elbow. It is the air bleed
point for the system. The soap will not
flow properly if the elbow is blocked.
2. Connect one end of the connection hose to
the coupling cap on the side of the tank.
INSTALLATION PROCEDURE - Sub Tank Unit
Sub-tank
Connection hose
Hose clamp
Hose clamp
Connection
hose
Elbow
Hose tie
Air
Wood Screw
Air deflation hose
Be sure that the hose tie is in position with
the air deflation hose and the elbow.
Be sure to install the elbow between the
top of the sub-tank and the counter.
When the elbow is installed lower than
the sub tank the soap overflows.
Check
Check
Caution
Be sure to tighten the hose connection with the
hose clamp to secure it into place.
Caution
Be sure to tighten the air deflation hose
securely with the hose clamp.
Caution
Do not have kinks or excessive bends in the
hose.
Check that all cap nuts are tight.
If loose, liquid leaks.
Check them periodically.
Hose clamp
Tank
Air deflation hose
ENGLISH
14
INSTALLATION PROCEDURE - Sub Tank Unit
(Continued)
GOOD GOOD
Y-shaped nipple
Connection hose
Connection hose
The total length of the connection hose is
16.4′ (5 m).
To ensure sufficient supply performance, do
not use a hose that is longer than 16.4′ (5
m).
Please install the hose horizontally.
Up to two tanks can be connected to one
sub-tank. Attach the Y-shaped nipple to
sub-tank to divert the connection hoses and
connect them to each of the tanks.
Install the hose in a straight line.
A bent hose will prevent the smooth flow of
liquid soap.
Position the tanks on a level surface at even
height. Installing the tanks at different levels
may result in the following malfunctions:
Soap leakage from the tank that is at a
lower level.
Improper detection of the liquid soap level
in the tank at the higher level.
Note
Hose length max 16.4′ (5 m)
ENGLISH
14
INSTALLATION PROCEDURE - Sub Tank Unit
(Continued)
GOOD GOOD
Y-shaped nipple
Connection hose
Connection hose
The total length of the connection hose is
16.4′ (5 m).
To ensure sufficient supply performance, do
not use a hose that is longer than 16.4′ (5
m).
Please install the hose horizontally.
Up to two tanks can be connected to one
sub-tank. Attach the Y-shaped nipple to
sub-tank to divert the connection hoses and
connect them to each of the tanks.
Install the hose in a straight line.
A bent hose will prevent the smooth flow of
liquid soap.
Position the tanks on a level surface at even
height. Installing the tanks at different levels
may result in the following malfunctions:
Soap leakage from the tank that is at a
lower level.
Improper detection of the liquid soap level
in the tank at the higher level.
Note
Hose length max 16.4′ (5 m)
ENGLISH
15
Installation Completion Drawing
Elbow
Air deflation hose
Sub-tank supply
Sub-Tank
Connection hose
Tank
Coupling Cap
ENGLISH
16
1. Shift the mode to the installation checking mode.
When your hand is held under the sensor for about 8 sec during
the first 10 minutes after the power is turned on, the mode shifts
to the “Installation Mode”.
During sensing, the liquid soap pump is driven and the liquid
soap continues to come out. (30 sec at maximum)
The liquid soap stops when your hand leaves the sensor.
Use this function for filling an empty flow path with liquid soap.
3. Check the tank and the connection of the
liquid soap hose for any liquid soap leaks.
TESTING
Checking after the completion of installation.
After installation is complete, confirm that the dispenser is working properly using the following method.
After the installation has been compleated, test the product using the following procedure.
Caution
If more than 10 minutes pass since the power was turned on, pull out the power plug and insert it
again.
When disconnecting and reconnecting the power plug , pull out the power plug and leave it
unplug for longer than 10 sec.
Caution
If the product is not used for a long period of time after installation, liquid soap remaining in the
hose dries and dispenses poorly. Therefore, conduct the trial run with water.
After the trial run, leave water accumulated in the tank as is and replace it with liquid soap at the
beginning of actual use.
Sensor
Checking for leaks
2. Dispense and stop the liquid soap.
The liquid soap comes out when you bring
your hand under the sensor.
The liquid soap stops when your hand
leaves the sensor.
ENGLISH
16
1. Shift the mode to the installation checking mode.
When your hand is held under the sensor for about 8 sec during
the first 10 minutes after the power is turned on, the mode shifts
to the “Installation Mode”.
During sensing, the liquid soap pump is driven and the liquid
soap continues to come out. (30 sec at maximum)
The liquid soap stops when your hand leaves the sensor.
Use this function for filling an empty flow path with liquid soap.
3. Check the tank and the connection of the
liquid soap hose for any liquid soap leaks.
TESTING
Checking after the completion of installation.
After installation is complete, confirm that the dispenser is working properly using the following method.
After the installation has been compleated, test the product using the following procedure.
Caution
If more than 10 minutes pass since the power was turned on, pull out the power plug and insert it
again.
When disconnecting and reconnecting the power plug , pull out the power plug and leave it
unplug for longer than 10 sec.
Caution
If the product is not used for a long period of time after installation, liquid soap remaining in the
hose dries and dispenses poorly. Therefore, conduct the trial run with water.
After the trial run, leave water accumulated in the tank as is and replace it with liquid soap at the
beginning of actual use.
Sensor
Checking for leaks
2. Dispense and stop the liquid soap.
The liquid soap comes out when you bring
your hand under the sensor.
The liquid soap stops when your hand
leaves the sensor.
ENGLISH
17
HOW TO USE
Place Hands Under Dispenser Spout.
Dispenser Spout
When the sensor senses someone’s hands, it
dispenses a mousse-like liquid soap.
The dispensing time is approximately 0.5 second.
Dispensing stops when the hand is taken away
from the dispenser.
If one’s hands remain in front of the dispenser,
the mousse-like liquid soap will again be
dispensed after approximately a 3 seconds delay.
This process can be repeated up to three times.
In order to prevent misuse, the liquid soap
dispenser will stop dispensing after 3 times, but
repeated soap dispensing is possible by moving
the hands away and placing them in front of the
dispenser again.
*
This function does not work for the first 10 min.
after the power is turned on.
(See page 16 "Installation Mode")
Please do not obstruct the dispenser spout
opening.
The soap might fly off in an unexpected direction.
Please do not put foam on the tip of the
dispenser. If the sensor is blocked, it could
malfunction.
When the tip is blocked , please wipe away the
debris using a damp cloth.
ENGLISH
18
REFILLING THE TANK
If the soap is very slow to drain into the
tank where excessive bubbling occurs,
please clean the filter and cap area.
Please refill the tank with liquid soap when the internal sensor lamp (red) starts blinking.
Filling the Sub-Tank (Only if a sub-tank has been installed.)
When a sub-tank has been installed, please fill
the liquid soap from the opening in the sub-tank.
Note
Pour soap slowly to avoid bubbles in the tank.
Filter
1. Remove the cap on the tank.
Open
2. Slowly pour the liquid soap into the holding
tank.
Please keep an eye on the level as you
pour the liquid soap in slowly so that it
doesn’t become foamy. Please pour the
liquid soap through the built-in filter.
3. Firmly close the cap on the tank.
Please make sure that the cap is securely
in place after filling the tank.
Close
Sensor
ENGLISH
18
REFILLING THE TANK
If the soap is very slow to drain into the
tank where excessive bubbling occurs,
please clean the filter and cap area.
Please refill the tank with liquid soap when the internal sensor lamp (red) starts blinking.
Filling the Sub-Tank (Only if a sub-tank has been installed.)
When a sub-tank has been installed, please fill
the liquid soap from the opening in the sub-tank.
Note
Pour soap slowly to avoid bubbles in the tank.
Filter
1. Remove the cap on the tank.
Open
2. Slowly pour the liquid soap into the holding
tank.
Please keep an eye on the level as you
pour the liquid soap in slowly so that it
doesn’t become foamy. Please pour the
liquid soap through the built-in filter.
3. Firmly close the cap on the tank.
Please make sure that the cap is securely
in place after filling the tank.
Close
Sensor
ENGLISH
19
MODE ADJUSTMENT
Setting the Dispensing Volume of Liquid Soap
The dispensing volume of liquid soap has been adjusted to 0.04 o.z before shipping from the factory.
This volume can be changed to 0.06 o.z by pulling out the connector.
1. Remove the controller cover.
Note
If the connector is connected again, the liquid
soap dispense volume is reset to 0.04 o.z.
Caution
Tighten the screws securely.
If water is splashed over the tank, the water can
penetrate into the controller and cause damage.
2. Remove the connector cord from the hook.
3. Pull out the connector.
4. Hang the connector on the hook.
(To prevent loss)
5. Mount the controller cover.
Hook
Connector
Connector
Controller cover
Screw
Screwdriver
Controller cover
Screw
Screwdriver
Pay attention not to
pinch the cord.
ENGLISH
20
CARE AND CLEANING
For Light Cleaning
For Heavy-Duty Cleaning
Sensor surface
Dispenser spout
Detergents containing acid, chlorine bleach or
alkali.
Solvents like paint thinner or benzene.
Detergents with coarse granules, polishing
powder or cleanser. Nylon scrubbers, pot
scrubbers, brushes, etc.
Please use a cloth that has been soaked in water
and wipe away any debris adhering to the
dispenser or sensor.
After wiping away debris with a cloth containing a
suitable amount of a neutral, dishwashing
detergent, wipe clean with a damp cloth.
When cleaning around the sensor, please be
careful not to scratch the surface of the sensor.
Please avoid using cleansers that might scratch
the surface of dispenser.
These include:
ENGLISH
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112

Toto CP Guide d'installation

Taper
Guide d'installation

dans d''autres langues