Baumer FPDM 16P3921/S14 Mode d'emploi

Taper
Mode d'emploi
FPDM 16P3921/S14
10122958
Í?*,=ZÂÂ*Â\Î
1/2
IND. CONT. EQ
1DD2
Optoelektronische Sensoren
Photo electric sensors
Cellules opto-électroniques
Reflexions-Lichtschranke
mit Polarisationsfilter
Retro-reflective sensor
with polarization filter
Barrière réflex avec
filtres de polarisation
Canada
Baumer Inc.
CA-Burlington, ON L7M 4B9
Phone +1 (1)905 335-8444
China
Baumer (China) Co., Ltd.
CN-201612 Shanghai
Phone +86 (0)21 6768 7095
Denmark
Baumer A/S
DK-8210 Aarhus V
Phone: +45 (0)8931 7611
France
Baumer SAS
FR-74250 Fillinges
Phone +33 (0)450 392 466
Germany
Baumer GmbH
DE-61169 Friedberg
Phone +49 (0)6031 60 07 0
India
Baumer India Private Limited
IN-411058 Pune
Phone +91 20 66292400
Italy
Baumer Italia S.r.l.
IT-20090 Assago, MI
Phone +39 (0)2 45 70 60 65
Singapore
Baumer (Singapore) Pte. Ltd.
SG-339412 Singapore
Phone +65 6396 4131
Sweden
Baumer A/S
SE-56133 Huskvarna
Phone +46 (0)36 13 94 30
Switzerland
Baumer Electric AG
CH-8501 Frauenfeld
Phone +41 (0)52 728 1313
United Kingdom
Baumer Ltd.
GB-Watchfield, Swindon, SN6 8TZ
Phone +44 (0)1793 783 839
USA
Baumer Ltd.
US-Southington, CT 06489
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Abmessungen
Dimensions
Dimensions
4,3ø
LED
15,4
50
4
12 30
36 3
4
M12 x 1
50
*26,5
8,5
25
Alle Masse in mm
• All dimensions in mm
Toutes les dimensions en mm
* Senderachse
* Emitter axis
* Axe de l'émetteur
Elektrischer Anschluss
Connection diagram
Schéma de raccordement
0 V
PNP
WH (2)
BU (3)
BN (1)
BK (4)
Z
+VS
dark operate
teach-in
BN = Braun/brown/brun
BK = Schwarz/black/noir
WH = Weiss/white/blanc
BU = Blau/blue/bleu
Hellschaltung / light operate / com. claire
Dunkelschaltung / dark operate / com. sombre
Objekt nicht vorhanden / object not present / objet pas présent
Objekt vorhanden / object present / objet présent
LED
PNP=LOW NPN=HIGH
LED
NPN
=HIGH
PNP
=LOW
LED
NPN
=HIGH
PNP
=LOW
LED
NPN
=HIGH
PNP
=LOW
object not presentobject present
light operate
dark operate
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten.
• Disconnect power before connecting the sensor.
• Mettre l`installation hors tension avant le raccordement du détecteur.
Technische Änderungen vorbehalten Technical specifications subject to change Sous réserve de modifications techniques
FPDM 16P3921/S14
2/2
Montage und Justage
Mounting
Montage
Die Reflexionslichtschranke ist möglichst genau auf den Reflektor
(Zubehör) auszurichten. Zur Adaption (Teach-In high) muss der
Lichtweg vom Sensor zum Reflektor frei sein, d.h. es darf sich
kein Objekt dazwischen befinden. Nach einem Spannungs-
unterbruch ist keine neue Adaption notwendig. Die Reichweite
ist von dem verwendeten Reflektor abhängig.
Als Justierhilfe wird nach 2 s High-Signal am Teach-In Eingang
die Signalreserve durch die LED angezeigt. Schnelleres Blinken
bedeutet viel Reserve, langsameres wenig. Ist die LED dauernd
aus, ist eine korrekte Funktion nicht gewährleistet.
Solange der Teach-In Eingang high ist, wird am Ausgang angezeigt,
ob beim letzten Adaptionsvorgang genügend Signalreserve
erreicht wurde. Bei ausreichender Signalreserve ist der Ausgang
low.
Wird der Reflektor näher als 60 cm vom Sensor entfernt montiert,
so werden unter Umständen diffuse Objekte nicht erkannt.
Align the sensor to the reflector best possible. For automativ
adjustment (teach-in), remove all objects in the light beam path
from the sensor to the reflector. After a failure or break of the
supply, no new adjustment (teach-in) is necessary.The actual
range depends on the type of the reflector (see technical data).
For alignment aid, the LED shows the excess gain if the teach-
input stays high for longer than 2 seconds. Fast flashing of the
LED means much excess gain, slower flashing means less
excess gain. If the LED is continuosly off while the teach-input
stays high for longer than 2 seconds, no correct function is
guaranteed. As long as the teach-input is high, the output shows
whether the last automatic adjustment was with enough excess
gain or not. A low state means, the excess gain of the last
automatic adjustment was sufficient.
If the reflector is mounted closer than 60 cm to the sensor,
detection of diffuse objects can cause problems (see actual
range).
La barrière optique simple doit être ajustée le plus précisément
possible avec le réflecteur. Pour la correction (Teach In high),
l'espace entre le capteur et le réflecteur doit être libre de tout
objet. Après une coupure de courant, un nouvel ajustement
n'est plus nécessaire. La portée de détection est dépendante
du type de réflecteur utilisé.
L'aide de réglage se manifeste avec la LED après 2 secondes
(Teach In high) et indique le signal de réserve. La LED clignotant
rapidement indique un signal de réserve élevé. La LED clignotant
lentement indique un signal de réserve faible. La fonction n'est
plus garantie si la LED est éteinte. Aussi longtemps que l'entrée
Teach In est high, la sortie va nous informer si la signal de
réserve était suffisant lors de la dernière correction de détection.
La sortie est low si le signal de réserve est suffisant.
Le montage du réflecteur à une distance inférieur à 60 cm du
capteur peut entraîner une non-reconnaissance d'objets à
lumière diffuse.
Technische Daten
Technical data
Données techniques
Betriebsspannungsbereich Vs (UL-Class 2) Voltage supply range Vs (UL-Class 2) Plage de tension Vs (UL-Class 2)
max. Stromverbrauch Mittelw ert / Spitzenwert max. supply current average / peak max. Consommation Mo yenne / Valeure de pointe
max. Schaltstrom max. switching current max. Courant de sortie
Spannungsabfall Voltage drop Tension résiduelle
Ansprechzeit / Abfallzeit Response time / Release time Temps d'activation / Temps désactivation
Kurzschlussfest Short circuit protection Protégé contre courts-circuits
Verpolungsfest Reverse polarity protection Protégé contre inversion polarité
Betriebstemperatur Temperature range Température de service
Schutzklasse Protection class Classe de protection
Adaptionszeit Automatic adjustment time Temps d'ajustement automatique
Adaption ausführen Activate automatic adjustment Ajustement automatique activ
Normalbetrieb Normal operation Fonction normale
min. Zeit für Signal Teach-In min. pulse length teach signal Temps minimal pour Teacher
typische Anzahl Adaptionsvorgänge max. number of teach cycles (typical) Nombre typique de cycles d'ajustement
Betriebsreichweite Sb Actual range Sb Portée de fonctionnement Sb
Betriebsreichweite Sb Actual range Sb Portée de fonctionnement Sb
10 - 30 VDC
40 mA / 50 mA
200 mA
1,8 VDC
2,5 ms
ja / yes / oui
ja / yes / oui
-25...+65 °C
IP 67
25 ms
Teach-In high
Teach-In low
1 ms
10
7
0,6 m < Sb < 4 m
0,6 m < Sb < 2,5 m
  • Page 1 1
  • Page 2 2

Baumer FPDM 16P3921/S14 Mode d'emploi

Taper
Mode d'emploi