Bosch HCP56652UC Guide d'installation

Taper
Guide d'installation

Ce manuel convient également à

Hood
Installation Manual
Models:
HCP50652UC, HCP56652UC
Page 2
Table of
CONTENTS
Safety .................................................................................. 3
Important Safety Instructions ..................................... 3
Electrical Connection ......................................................... 5
Before you begin ............................................................... 6
Tools and parts needed .............................................. 6
Parts included ............................................................. 6
Appliance Dimensions ............................................... 6
Safety Clearances ....................................................... 7
Ventilator Performance Calculation ........................... 8
Installation Procedure ........................................................ 8
Preparing the Installation ........................................... 9
Connect Electrical Supply .......................................... 10
Attachingtheueduct..............................................11
Customer Service .............................................................. 12
Safety
DEFINITIONS
WARNING
This indicates that death or serious injuries may occur as a
result of non-observance of this warning.
CAUTION
This indicates that minor or moderate injuries may occur
as a result of non-observance of this warning.
NOTICE: This indicates that damage to the appliance or
property may occur as a result of non-compliance with this
advisory.
This Bosch appliance is made by
BSH Home Appliances Corporation
1901 Main Street, Suite 600
Irvine, CA 92614
Questions?
1-800-735-4328
www.bosch-home.com/us
We look forward to hearing from you!
Page 3
Safety
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: Save these instructions for the local electrical
inspector’s use. Please leave these instructions with this
unit for the owner. Show the owner the location of the
circuit breaker or fuse. Mark it for easy reference.
OWNER: Please retain these instructions for future
reference.
WARNING
If the information in this manual is not followed exactly,
reorshockmayresultcausingpropertydamageor
personal injury.
WARNING
If the information in this manual is not followed
exactly,reorshockmayresultcausingproper-
ty damage, personal injury or death.
- DONOTstoreorusegasolineorotherammable
vapors and liquids in the vicinity of this or any other
apppliance.
- WHAT TO DO IF YOU SMELL GAS
DO NOT try to light any appliance.
DO NOT touch any electrical switch.
DO NOT use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
Ifyoucannotreachyourgassupplier,callthere
department.
- Installation and service must be performed by an
authorized servicer, service agency or the gas supplier.
WARNING
Turn off power circuit at service panel and lock out panel
before wiring this appliance. Requirement: 120 VAC, 60
Hz 15 A. Allow the appliance to cool after the power has
been turned off before servicing the appliance.
WARNING
Automatically Operated Device
To reduce the risk of injury disconnect from power supply
before servicing.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer at the address or telephone number
listed on the back page.
Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
WARNING
DO NOT repair or replace any part of the appliance
unlessspecicallyrecommendedinthemanuals.
Improper installation, service or maintenance can cause
injury or property damage. Refer to this manual for
guidance. All other servicing should be done by an
authorized servicer.
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT remove connections.
DO NOT use an extension cord.
Failure to follow these instructions can
resultindeath,re,orelectricalshock.
Page 4
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
Grounding Instructions
WARNING
Improper grounding can result in a risk of electric shock.
This appliance must be grounded. In the event of an electri-
cal short circuit, grounding reduces the risk of electric shock
by providing an escape wire for the electric current.
Be sure your appliance is properly installed and grounded
byaqualiedtechnician.Installation,electricalconnections
and grounding must comply with all applicable codes.
If required by the National Electrical Code (or Canadian
Electrical Code), this appliance must be installed on a sepa-
rate branch circuit.
WARNING
Toreducetheriskofreorelectricalshock,DO NOT use
this appliance with any solid state speed device.
Safety Codes and Standards
This appliance complies with one or more of the following
Standards:
UL 507, The Standard for the Safety of Electric Fans
CSA C22.2 No. 113, Fans and Ventilators
It is the responsibility of the owner and the installer to de-
termine if additional requirements and/or standards apply
tospecicinstallations.
CAUTION
Unit is heavy and requires at least two people
or proper equipment to move and install.
Hidden surfaces may have sharp edges. Use
caution when handling the appliance. Failure
to do so may result in property damage or
personal injury.
Proposition 65 Warnings
This product may contain a chemical known to the State
of California, which can cause cancer or reproductive
harm. Therefore, the packaging of your product may
bear the following label as required by California:
STATE OF CALIFORNIA PROPOSITION 65 WARNING:
WARNING
Cancer and reproductive harm - www.P65Warnings.ca.gov.
Never modify or alter the construction of the appliance.
For example, do not remove panels, wire covers or
brackets/screws.
CAUTION
For general ventilating use only. DO NOT use to exhaust
hazardous or explosive materials and vapors.
WARNING
Toreducetheriskofre,useonlymetalductwork.
Useaqualiedinstaller.
Remove all tape and packaging before using the
appliance. Destroy the packaging after install. Never allow
children to play with packaging material.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
Installation work and electrical wiring must be done
byqualiedperson(s)inaccordancewithall
applicablecodesandstandards,includingre-related
construction.
Sufcientairisneededforpropercombustionand
exhaustingofgasesthroughtheue(chimney)of
fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer’s
guideline and safety standards such as those
published by the National Fire Protection
Association (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
Page 5
Electrical Connection
WARNING
RISK OF ELECTRIC SHOCK
Parts inside the appliance can have sharp edges.
The connection cable can be damaged. Do not
bend or pinch connection cables during installation.
Before connecting the appliance, check the household
electricalsupply.Ensuresufcientfuseprotectionofthe
household electrical supply. The voltage and frequency of
the appliance must match the electrical installation (see
rating plate).
The appliance complies with protection class 1 and must
only be operated in conjunction with a protective conduc-
tor terminal.
An all-pole isolating switch with at least a 3 mm contact
gapmustbettedintheinstallation.Thismustremain
accessible after installation.
Onlyaqualiedelectricianwhotakestheappropriate
regulations into account may lay or replace the
connecting cable. Follow all standards, regulations and laws.
Ensure that the electrical connection meets the require-
ments of the latest version of all applicable standards,
regulations and laws in the appropriate country, especially
the following standards:
National Electrical Code, ANSI/
NFPA 70*, or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No.0-M91**.
Haveaqualiedelectricaltechniciancheckthegrounding
of the appliance.
Do not ground with a gas line.
No fuse protection in the neutral or grounding circuit.
Keep these installation instructions. Only connect the
appliance with a copper conductor. If possible, connect
the appliance to a metal cable guide directly to the fuse
box.
Ensure that the wire diameter meets the requirements of
the latest version of all applicable standards and laws in
the appropriate country, especially the following
standards: National Electrical Code, ANSI/NFPA 70*, or
CSA Standards C22.1-94, Canadian Electrical Code, Part
1 and C22.2 No.0-M91**.
Put a protecting hose that is listed in the U.L. or C.S.A. on
both ends of the connecting cable, that is, on the
appliance and on the fuse box.
For copies of the standards listed, contact:
* National Fire Protection Association Batterymarch Park
Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE
FIRE:
Never leave surface units unattended at high
settings.
Boilovers cause smoking and greasy spillovers that
may ignite. Heat oils slowly on low or medium
settings.
Always turn hood ON when cooking at high heat
orwhencookingambéingfood(i.e.CrepesSuzette,
Cherries Jubilee, Peppercorn Beef Flambe).
Clean ventilating fans frequently. Grease should
notbeallowedtoaccumulateonfanorlter.
Use proper pan size. Always use cookware
appropriate for the size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN
THE EVENT OF A RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING:
a
SMOTHERFLAMESwithaclosettinglid,cookie
sheet, or metal tray, then turn off the burner. BE
CAREFULTOPREVENTBURNS.Iftheamesdonot
go out immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
NEVER PICK UP A FLAMING PAN - you may get
burned.
DO NOT USE WATER, including wet dishcloths or
towels - a violent steam explosion will result.
Use an extinguisher ONLY if:
a) You know you have a class ABC extinguisher,
and you already know how to operate it.
b) Thereissmallandcontainedintheareawhere
it started.
c) Theredepartmentisbeingcalled.
d) Youcanghttherewithyourbacktoanexit.
a
Based on “Kitchen Fire Safety Tips” published by NFPA.
Page 6
Before you begin
Tools and Parts Needed
Measuring tape
Pencil
Phillips screwdriver (Posidrive) #2
Drill with the following bits:
5
16” (7.9 mm) and
3
8
(9.5 mm)
Spirit-level
Aluminum tape (DO NOT use insulating tape)
Exhaustchannel(congurationdependsonthe
installation situation)
Additional sheet metal screws (if necessary for
installation of the exhaust air duct)
Saw
Home power supply cable
1/2” (13 mm) UL listed or CSA approved strain relief
Three UL Listed wire connectors
Parts Included
Extractorhoodwithfan,back-pressureap
Lamps, already installed
Metalgreaselter
Flue duct
Drill template
1xanglebracketfortheueduct
Installation manual and instructions for use
6x screws, 5x45 mm
12x screws, 4.2x8 mm
2x washers, 6.4x18 mm
2x hollow wall plugs, 8x40 mm
4x hollow wall plugs, 10x50 mm
Torx adapter, 10 & 20
NOTE:Carefullyremovetheprotectivelmfromtheduct
cover and hood assembly prior to the start of the installation.
Use one hand to maintain the assembly/duct cover steady
whiletheotherhandremovestheprotectivelm.
Use gloves at all time.
Appliance Dimensions
30" (762 mm)
36" (914 mm)
A
19
11
/
16
"
(500 mm)
7
7
/
8
"
(200 mm)
10
3
/
4
"
(273 mm)
13
3
/
16
"
(335 mm)
5¾"
(146 mm)
A Only for circulating-air mode:
*Max. 43
1
2" (1106 mm)
*Min. 29" (734 mm)
Only for ducted operation:
*Max. 39
1
2" (1006 mm)
*Min. 25" (633 mm)
Page 7
Fan operation
Note: Ventilation may not exit through an already
operational smoke or exhaust chimney, nor a duct used
for ventilating furnace installation areas.
If the ventilation is intended to pass through a smoke
or exhaust chimney that is not in operation, the
responsible area heating inspector must give approval.
If the ventilation passes through an external wall, use a
telescope wall sleeve.
Ventilation line
Note: The device manufacturer is not responsible for the
operation or complaints associated with the pipe section.
The ventilation opening and the exhaust air ducts must
be made according to the local requirements.
The device achieves its optimum performance by
means of a short, straight exhaust air pipe and as
large a pipe diameter as possible.
As a result of long rough exhaust air pipes, many pipe
bends or too-small diameters, the optimum extraction
performance is not achieved and fan noise is increased.
The pipes or hoses for laying the exhaust air line must
consist of non-combustible material.
Smooth the connection area of the pipes before
installation.
Seal the connection points of the pipes appropriately.
Round pipes
An inner diameter of Ø 8” (200 mm) is recommended.
Checking the wall
The wall must be level, vertical and adequately loa
bearing.
The depth of the bore holes must be the same length
as the screws. The wall plugs must have a secure grip.
The enclosed screws and wall plugs are suitable for
solid brickwork. Suitable fasteners must be used for
other structures.
Safety clearances
WARNING
RISK OF FIRE
Greasedepositsinthegreaseltercancatchre.
The given safety clearance must be observed to avoid
heatbuildup.Observethespecicationsforyourcooking
appliance. If gas and electric cooktops are used together,
the largest given clearance applies.
The appliance may only be installed directly next to a
cabinet or wall on one side. The wall or cabinet clearance
must be at least 2” (50 mm).
The clearance between the shelf on the cooktop and the
bottom of the extractor hood may not be less than 30” (762
mm) in the case of electric cooktops and gas or combined
ranges.
If the installation instructions for the gas cooking
appliance specify a larger distance, this must be taken into
account.
Electrical & Gas cooktop
min. 30" (762 mm)
Page 8
Installation Procedure
The ducting from this fan to the outside of the building has
astrongeffectontheairow,noiseandenergyuseofthe
fan. Use the shortest, straightest duct routing possible for
best performance, and avoid installing the fan with smaller
ducts than recommended. Insulation around the ducts can
reduce energy loss and inhibit mold growth. Fans installed
withexistingductsmaynotachievetheirratedairow.
Ensure duct joints and exterior penetrations are sealed
with caulk or other similar material to create an air-tight
path and to minimize building heat loss and gain and
reduce the potential for condensation.
Place/wrap insulation around duct and/or fan to in order to
minimize possible condensation buildup within the duct,
building heat loss and gain.
CAUTION
Ensure that there are no electric wires, gas or water pipes
in the area where holes are to be made.
Ventilator Performance Calculation
Size (in)
Eq uivalent
Length (ft)
Size (in)
Eq uivalent
Length (ft)
61.2
61
0
80.7
10 0.6
" x 10", straight N/A1
" x 10", Center
reverse elbow, right
N/
A2
5
" x 14", straight N/A0.7
" x 10", Left
reverse elbow
N/
A1
5
" x 10", Right
reverse elbow
N/
A2
5
612
62
86
82
10
10 2
65
62
2
5
83
82
2
2
10
10
" x 10",
90° elbow, round
N/A5
2’ long, 3¼" x 10" flexN/A 20
" x 10",
45° elbow, round
N/A15
" x 10", Flat elbowN/A 20
61
810
82
" x 10", Roof jack
and shutter
N/A
65
61
0
NOTE: These commonly used installation parts can be purchased at a
local hardware store. Bosch does not manufacture all these parts.
Round wall cap
Round roof cap
" x 10" to round
90° elbow,
Duct Piece
" x 10" Center
reverse elbow, left
15N/A
Round to 3¼" x 10"
" x 10" to round
Round to 3¼" x 10"
90° elbow,
Duct Piece
Smooth, straight
90° elbow, round
45° elbow, round
Roof
Venting
Wall
Venting
Non Vented
(Recirculating)*
A. Roof ca
p
B. 8" (20.3 cm)
round vent
C. Seal duct joints
with duct tape/
caulk
A. Wall cap
B. 8" (20.3 cm)
round vent
C. Seal duct joints
with duct tape/
caulk
A. Diverter
B. 8" (20.3 cm)
round vent
C. Seal duct joints
with duct tape/
caulk
A
B
C
A
B
C
B
C
Page 9
Preparing the installation
1. Mark a vertical center line on the wall from the ceiling
to the lower edge of the extractor hood.
2. Align the drill template on the center line and the
bottom edge of the extractor hood and glue on.
3. Mark positions for the screws and the contour of the
attachment area.
4. Markholesfortheue’sanglebrackets.Thecenterof
the angle bracket is marked with a hole. Place the
angle brackets in the center of the center line, align
them horizontally and mark the positions of the holes.
B
C
A
A Ceiling
B Wall
C Centerline
Fitting the wall retainer
1. Drill holes with Ø 5/16” (7.9 mm) for the angle bracket.
2. Pressinthewallplugsushwiththewall.
3. Screw screws (5x34 mm) into the wall plugs by hand
in order to spread the plugs apart.
4. Unscrew screws.
5. Screwontheanglebracketfortheueduct.
Making the ceiling breakthrough
1. Using a spirit level, extend the center line of the drill
template to the ceiling.
2. Mark the ceiling breakthrough (Ø 8 1/2” (216 mm)) at
least 4 5/8” (117 mm) away from the wall.
Making the wall breakthrough
1. Using a spirit level, extend the center line of the drill
template to the ceiling.
2. Depending on the curved section of the wall
breakthrough (Ø 8 1/2” (216 mm)) mark at least
26 1/2” (660 mm) above the bottom edge of the
extractor hood.
Mounting the back-pressure flap
1. Using 4 screws (4.2 x 8 mm), attach the air transition
spacer to the hood.
2. Using 4 screws (4.2 x 8 mm), attach the back-pressure
apandtheairtransitionspacer.
A
B
A Transition Spacer
B Air Transition
Mounting the extractor hood on the wall
WARNING
RISK OF INJURY
The appliance is heavy. To move the appliance, 2 people
are required. Use only suitable tools and equipment.
1. Initially remove the protective foil from the back of the
appliance and, following installation, remove foil
completely.
2. Mark the upper holes on the wall.
Note: Ensure that the holes are horizontal and aligned
centered on the center line.
3. Drill the upper holes. Adhere to a distance of 1/4”
(6 mm) between the wall and screw head.
4. Removegreaselters.
5. Hang the extractor hood on the upper screws on the
wall.
6. Mark holes for the lower holes.
7. Remove the extractor hood from the wall.
8. Drill the lower holes.
9. Hang the extractor hood on the upper screws on the
wall.
Page 10
10. Tighten the upper and lower screws by hand.
Connecting the air extractor (only for ducted operation)
Note: If an aluminum pipe is used, smooth the connection
area beforehand.
1. Attach exhaust air pipe and seal.
2. Checkwhethertheback-pressureapworks.
Mounting the recirculation model
(only for circulating-air mode)
1. Use 4 screws (4x8 mm) to screw the housing to the
angle bracket.
A
B
C
A Screws
B Recirculation module
C Angle bracket
2. Measure the distance (x) between the bottom edge of
the housing for the recirculation module and the
bottomedgeoftheback-pressureap.
A
x
B
C
D
A Recirculation module
B Clamps
C Flue duct
D Exhaust air duct
3. Shorten the exhaust air pipe to the length measured.
4. Remove the recirculation module.
5. Push the exhaust air pipe onto the bottom side of the
recirculation module.
6. Position the recirculation module with exhaust air pipe
over the air extraction duct of the extractor hood.
7. Use 4 screws to fasten the recirculation module to the
angle bracket.
8. Secure connections with clamps.
Connect Electrical Supply
WARNING
RISK OF ELECTRIC SHOCK
Before wiring the appliance, interrupt the main electrical
circuit at the electrical control cabinet. A circuit with 120
VAC, 15 or 20 Ampere is required.
Grounding notes: this appliance is equipped with a
distributor box with 3 cables. Use the green-yellow cable
for grounding the appliance. Connect the green-yellow
cable to the grounding cable on the house connection to
prevent electric sthock. Do not under any circumstances
damage or remove the green-yellow cable. Non-adheren-
ce can cause serious injuries or electric shock.
1. Unplug the cable connector located on the top of the
junction box.
2. Remove the cable passage and the junction box cover.
B
A
A Cable passage
B Cover of the junction box
3. Connect 1/2” (12.7 mm) strain relief to the junction box.
4. Run home power supply cable through strain relief,
into terminal box.
5. Use UL listed wire connectors and connect black wires
(C) together.
6. Use UL listed wire connectors and connect white wires
(D) together.
Page 11
7. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (E) in terminal box
using UL listed wire connectors.
B
A
C
D
E
A Installation pipe
B Cable connector listed in UL
C Black wires
D White wires
E Yellow-green ground wire
8. Tighten strain relief screw.
9. Install the junction box cover.
10. Plug the cable connector located on the top of the
junction box.
Attaching flue duct
Hidden surfaces may have sharp edges. Use caution
when reaching behind or under appliance.
1. Removetheprotectivefoilfrombothueducts.
2. Pushoneueductintotheother.
Notes
To prevent scratches, lay paper over the edges of
thelowerueducttoprotectthesurface.
Forductedoperation,turntheupperueductso
that the ventilation slots point downward.
3. Remove the protective foil from the extractor hood.
4. Placeueductsontheappliance.
5. Pushtheinnerueductupwardsandattachittothe
angle brackets on the left and right.
6. Screwtheueducttothesidesoftheanglebracket
using two screws.
AB
7. Fastenthelowerpartoftheueductusingtwo
screws.
8. Removetheprotectivepaperfromthelowerueduct.
9. Installmetal-meshgreaselter.
Removing the appliance
1. Removethemetal-meshgreaselter.
2. Loosentheueduct.
3. Disconnect the appliance from the power supply.
4. Loosen the exhaust air lines.
5. Loosen screws for fastening the appliance.
6. Remove the appliance.
Page 12
Customer service
Our customer service department is there for you if your
appliance requires repair. When calling, please give the Pro-
duct Number (P-No.) and the Serial Number (S-No.) so that
wecanofferyouthebestservice.Theidenticationplate
listing the numbers can be found inside of the appliance
(removemetalgreaseltertondit).
So that you don’t have to search for them when you need
them, you can enter your appliance information and the
customer service number here.
P-No. S-No.
Customer service O
Please note that a service visit to provide instruction on the
use of the appliance is not covered by the warranty.
Pleasendthecontactdataofallcountriesinthe
enclosed customer service list.
To book service or for product advice
US 800 944 2904
toll-free
Page 13
Table des
MATIÈRES
Sécurité..............................................................................14
ConsignesdeSécuritéImportantes...........................14
Branchementélectrique....................................................17
Avant de commencer ........................................................ 17
Outilsetpiècesnécessaires...................................... 17
Pièces comprises ........................................................ 17
Cotes de l’apparei ...................................................... 18
Distancesdesécurité.................................................18
Longueurséquivalentesdeconduites
pourpiècesdetransitionhabituellementutilisée.....19
Procédured’installation.....................................................19
Preparing the Installation ........................................... 20
Connect Electrical Supply .......................................... 21
Attachingtheueduct..............................................22
Service après-vente ............................................................ 23
Dénitions de
SÉCURITÉ
AVERTISSEMENT
Ceci indique que le non respect de cet avertissement
peut entraîner des blessures graves, voire la mort.
ATTENTION
Ceci indique que le non respect de cet avertissement
peutentraînerdesblessureslégèresoumodérées.
AVIS:Ceciindiquequelanon-conformitéàcetavisde
sécuritépeutentraînerdesdégâtsàl’appareilouàlapro-
priété.
Remarque: Ceci vous avertit que d’importantes informa-
tions et/ou conseils sont fournis.
Cet appareil électroménager de Bosch
est fait par BSH Home Appliances LtD
6696 Financial Drive, Unit 3
Mississauga, ON L5N 7J6
Des questions?
1-800-735-4328
www.bosch-home.com/us
Nous attendons de vos nouvelles!
Page 14
Sécurité
CONSIGNES DE SÉCURITÉ IMPORTANTES
LIRE ET CONSERVER CES CONSIGNES
INSTALLATEUR: Conservezcesconsignesàl’intentionde
l’inspecteurélectriquelocal.Laissezcesconsignesavec
l’appareilàl’intentiondupropriétaire.Montrezauproprié-
taire l’emplacement du disjoncteur ou du fusible du circuit.
Identiezsapositionpourpouvoirleretrouverfacilement.
PROPRIÉTAIRE: Prière de conserver ces consignes pour
pouvoirs’yréférerultérieurement.
AVERTISSEMENT
Silesconsignesduprésentmanuelnesontpassuivies
àlalettre,ilyaunrisqued’incendieoud’électrocution
pouvantentraînerdesdommagesmatérielsoudesbles-
sures.
AVERTISSEMENT
Silesconsignesduprésentmanuelnesontpas
suiviesàlalettre,ilyaunrisqued’incendieou
d’électrocutionpouvantentraînerdesdom-
magesmatériels,desblessuresoulamort.
- NE PAS conserver ou utiliser de l’essence ou d’autres
liquidesetvapeursinammablesàproximitédecet
appareilélectroménageroudetoutautreappareil.
- QUE FAIRE SI VOUS PERCEVEZ UNE ODEUR DE GAZ
NE PAS essayer de mettre un appareil
électroménagersoustension.
NEPAStoucherd’interrupteurdecourantélectrique.
NEPASutiliserdetéléphonesdansl’édice.
Communiquerimmédiatementaveclefournisseur
degazdepuisl’appareiltéléphoniqued’unvoisin.
Respecter les directives du fournisseur de gaz.
S’il s’avère impossible de joindre le fournisseur
de gaz, communiquer avec les pompiers.
- Utiliserlesservicesd’untechnicienenréparationou
d’uneagencederéparationsautorisés,oule
fournisseurdegaz,pourprocéderàl’installationet
auxréparations.
AVERTISSEMENT
Couperl’alimentationducircuitélectriqueauboîtieràfu-
siblesoudesdisjoncteursetleverrouilleravantdecâbler
cetappareilélectroménager.Exigences:120Vc.a.,60
Hzet15A.Aprèslacoupuredel’alimentationélectrique,
laisserrefroidirl’appareilélectroménageravantdeprocé-
derauxréparations.
AVERTISSEMENT
Dispositifàfonctionnementautomatique
Couperl’alimentationélectriqueavanttouteréparation
pourréduirelerisquedeblessure.
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE D’INCENDIE,
D’ÉLECTROCUTION OU DE BLESSURES, RESPECTER
LES INDICATIONS SUIVANTES:
Utilisercetappareiluniquementdelafaçonprévue
par le fabricant. Pour toutes questions, communiquer
aveclefabricantàl’adressedeladernièrepageouau
numérodetéléphoneinscrit.
Avantderépareroudenettoyerl’appareil,couper
l’alimentationélectriqueaudispositifde
sectionnementetleverrouillerpouréviterque
l’alimentationnesoitrétablieaccidentellement.
Lorsque le dispositif de sectionnement ne peut pas
êtreverrouillé,xerunaccessoired’avertissement
visibleetadéquat,commeuneétiquette,auboîtierà
fusibles ou des disjoncteurs.
AVERTISSEMENT
NE PASréparerouremplacerunepiècedel’appareil
électroménager,àmoinsquelesmanuelsrecommandent
de le faire.
Uneinstallation,uneréparationouunentretien
incorrect(e) peut entraîner des blessures ou des dom-
magesmatériels.Consulterleprésentmanuelpour
connaîtrelesdirectives.Touteautreréparationdoitêtre
effectuéeparuntechnicienenréparationautorisé.
AVERTISSEMENT
RISQUE D’ÉLECTROCUTION
NE PAS enlever les raccords.
NE PAS utiliser de rallonge.
• Toutmanquementàcesdirectivespeut
entraîner la mort ou une
Page 15
CONSIGNES DE SÉCURITÉ IMPORTANTES
LIRE ET CONSERVER CES CONSIGNES
Directives de mise à la terre
AVERTISSEMENT
Unemiseàlaterreinadéquatepeutentraînerunrisque
d’électrocution.
Cetappareilélectroménagerdoitêtremisàlaterre.En
casdecourt-circuitélectrique,lamiseàlaterreréduitle
risqued’électrocutionenoffrantaucourantélectriqueunl
d’évacuation.
Assurez-vousquel’appareilestcorrectementinstalléet
misàlaterreparuntechnicienqualié.L’installation,les
raccordementsélectriquesetlamiseàlaterredoiventêtre
conformes avec tous les codes en vigueur.
S’ilyalieu,conformémentauCodenationaldel’électricité
(ouauCodecanadiendel’électricité),cetappareilélec-
troménagerdoitêtreinstallésuruncircuitdedérivation
distinct
AVERTISSEMENT
NE PASutilisercetappareilélectroménageravecundis-
positif de contrôle de la vitesse semi-conducteur pour
Codes et normes de sécurité
Cetappareilélectroménagerestconformeàuneouplu-
sieurs des normes suivantes :
• UL507,Normeenmatièredesécuritépourles
ventilateursélectriques
CSA-C22.2 no 113, Ventilateurs
Ilincombeaupropriétaireetàl’installateurdedéterminer
si des exigences et/ou normes additionnelles s’appliquent
pourdesinstallationsspéciques.
MISE EN GARDE
L’appareilestlourdetsondéplacementetins-
tallation exigent au moins deux personnes ou
encoreunéquipementapproprié.
Dessurfacescachéespeuventavoirdesre-
bords tranchants. Faire attention en manipulant
l’appareilélectroménager.Toutmanquement
àcetteconsignepourraitentraînerdesdom-
magesmatérielsoudesblessures.
Nejamaismodiernialtérerlastructure(fabrication)de
l’appareilélectroménager.Parexemple,nepasretirerles
panneaux,lescouvre-ls,lessupports,leséquerresde
xationoulesvis.
Avertissement issu de la proposition 65
Ce produit pourrait contenir un produit chimique reconnu
parl’ÉtatdelaCaliforniecommecancérigèneouayantdes
effetsnocifssurlareproduction.Parconséquent,
l’emballagedevotreproduitpourraitporterl’étiquette
suivante, comme requis par la Californie:
AVERTISSEMENT ISSUE DE LA PROPOSITION 65 DE
L’ÉTAT DE LA CALIFORNIE:
AVERTISSEMENT
Canceretdommagesàlareproduction–
www.P65Warnings.ca.gov.
MISE EN GARDE
Uniquementauxnsdeventilationgénérale.NE PAS
utiliserpourévacuerdesmatièresetdesgazdangereux
ou explosifs.
AVERTISSEMENT
Pourréduirelerisqued’incendie,utiliseruniquementdes
systèmesdegaines/conduitesenmétal.
Utilisezlesservicesd’uninstallateurqualié.
Retirez tout le ruban et l’emballage avant d’utiliser
l’appareilélectroménager.Jetezl’emballageaprès
l’installation. Ne laissez jamais les enfants jouer avec le
matérield’emballage.
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE D’INCENDIE,
D’ÉLECTROCUTION OU DE BLESSURES, RESPECTER
LES INDICATIONS SUIVANTES :
Lestravauxd’aménagementetdecâblageélectrique
doiventêtreexécutéspardupersonnelqualiéen
conformitéàtouslescodesetàtouteslesnormes
de construction en vigueur, incluant ceux concernant
les incendies.
Unapportd’airsufsantestnécessairepourlabonne
combustionetévacuationdesgazparlecarneau
(cheminée),émanantdetoutappareildecombustion
and’éviterlerefoulementdel’air.Respecterles
lignes directrices du fabricant des appareils de
chauffageetlesnormesdesécuritécommecelles
établiesparlaNationalFireProtectionAssociation
(NFPA), la American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) et les c
desdesautoritéslocales.
Page 16
CONSIGNES DE SÉCURITÉ IMPORTANTES
LIRE ET CONSERVER CES CONSIGNES
En coupant ou perçant un mur ou un plafond pour
l’installation de l’appareil, s’assurer de ne pas
endommagerlecâblageélectriqueetlesautres
servicespublicsmasqués.
Lesventilateursraccordésàuneconduitedoivent
toujoursévacuerl’airversl’extérieur.
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE D’INCENDIE DE GRAISSE
DE CUISINIÈRE:
Ne jamais laisser la surface de cuisson sans
surveillanceàfeuvif.
Lesdébordementscausentdelafuméeetlesrésidus
graisseuxpeuvents’enammer.Fairechauffer
lentementleshuilesàfeudouxoumoyen.
Toujours faire FONCTIONNER la hotte lorsque vous
cuisinezàfeuvifoupourambercertainsplats
(c.-à-d.,crêpesSuzette,cerisesJubilé,steakaupoivre
ambé).
Nettoyerrégulièrementlesventilateurs.Nepaslaisser
lagraisses’accumulersurleventilateurouleltre.
Utiliserdescasserolesdetailleappropriée.Toujours
utiliserdesustensilesdecuisineadaptésàlataillede
l’élémentdecuisson.
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE DE BLESSURES EN CAS
D’INCENDIE DE GRAISSE DE CUISINIÈRE, RESPECTER
LES CONSIGNES SUIVANTES:
a
ÉTOUFFER LES FLAMMES avec un gros couvercle
bienajusté,uneplaqueàbiscuitsouunplateaude
métalpuisfermerlebrûleur.ÊTREPRUDENT,
ÉVITERLESBRÛLURES.Silesammesne
s’éteignentpasimmédiatement,ÉVACUERLES
LIEUX ET APPELER LES POMPIERS.
NEJAMAISSOULEVERUNEPOÊLEENFEU:vou
risquezd’êtrebrûlé.
NEPASUTILISERD’EAU,ycomprisuntorchonà
vaisselleouuneserviettemouillé,celaentraînera
une explosion violente de vapeur.
Utiliser un extincteur UNIQUEMENT si:
a) Vous savez que vous disposez d’un extincteur de
classeABCetsavezdéjàcommentl’utiliser.
b) Lefeuestpetitetconcentrédanslazoneoùila
commencé.
c) Vousavezappelélespompiers.
d) Vous pouvez combattre l’incendie avec une sortie
derrière vous.
a
Explicationsfondéessur«KitchenFireSafetyTips»
(Conseilsdesécuritéencasd’incendiedecuisine)pu-
bliéesparlaNFPA.
Page 17
Avant de commencer
Outils et pièces nécessaires
Décamètreàruban
Crayon
Tournevis Phillips (Posidrive) #2
Perceuse avec les forets suivants : 5/16” (7,9 mm) et
3/8” (9,5 mm)
Niveauàbulle
Ruban en aluminium (NE PAS utiliser un ruban isolant)
Canald’évacuationd’air(lacongurationdépenddela
situation de montage).
Visàtôlesupplémentaires(sinécessairespour
l’installationduconduitd’évacuation)
Scie
Cordon d’alimentation
Réducteurdetensionde1/2”(13mm)répertoriéULou
approuvéparCSA.
TroisconnecteursdellistésUL
Pièces comprises
Hotte aspirante avec ventilateur, volet anti-refoulement
Lampe,déjàmontée
Filtreàgraisseenmétal
Capotdecheminée
Gabarit de perçage
1cornièrederetenuepourlecapotdecheminée
Notice d’utilisation et d’installation
6 vis, 5 x 45 mm
12 vis, 4,2 x 8 mm
2x rondelles
2x chevilles pour corps creux, 8x40 mm
4x chevilles pour corps creux,10x50 mm
Adaptateur Torx, 10 & 20
REMARQUE:Retirezdélicatementlelmdeprotection
ducouvercleduconduitetducapotavantledébutde
l’installation. Utilisez une main pour maintenir le couvercle de
l’ensemble / conduit stable tandis que l’autre main enlève le
lmdeprotection.
Branchement électrique
AVERTISSEMENT
RISQUE DE CHOC ÉLECTRIQUE
Les pièces se trouvant dans l’appareil peuvent
présenterdesarêtesvives.Lecordondebranchement
peutêtreendommagé.Nepascoudernicoincerlecor-
don de branchement pendant la pose.
Avantderaccorderl’appareil,vérierl’installation
domestique.Veilleràcequelaprotectiondel’installation
domestiquesoitappropriée.Latensionetlafréquencede
l’appareildoiventcorrespondreàl’installationélectrique
(voirlaplaquesignalétique).
L’appareilrépondàlaclassedeprotectionIetdoit
uniquementêtreutiliséavecuneprisedeterre.
Un sectionneur omnipolaire avec un interstice d’ouverture
decontactd’aumoins3mmdoitêtreprésentdans
l’installation. Celui-ci doit encore être accessible après
l’encastrement.
Seulunélectricienagrééesthabilitéàinstallerouà
remplacerlecâblederaccordement,enrespectantles
prescriptions en vigueur.
Respecter toutes les normes et lois en vigueur.
Veilleràcequeleraccordementélectriquerépondeaux
exigences de toutes les normes et lois applicables dans
lepayscorrespondantetauxspécicationsdeséditions
lesplusrécentesdesnormessuivantes:National
Electrical Code, ANSI/NFPA 70*, ou normes
CSAC22.1-94,Codecanadiendel’électricité,partie1et
C22.2 No.0-M91**.
Fairecontrôlerparunélectricienleraccordementàlaterre
de l’appareil.
Nepasmettreàlaterreavecunecanalisationdegaz.
S’assurer de ne pas avoir de fusible dans le circuit
électriqueneutreoudemiseàlaterre.
Conserver la notice de montage. Raccorder l’appareil
uniquementavecuncâblagedecuivre.Raccorder
l’appareilsipossibleavecunguidedecâblemétallique
directementauboîtieràfusibles.
Lediamètreduldoitrépondreauxexigencesdetoutes
les normes et lois applicables dans le pays
correspondantetauxspécicationsdeséditionslesplus
récentesdesnormessuivantes:NationalElectricalCode
ANSI/NFPA 70*, ou normes CSA C22.1-94, Code
canadiendel’électricité,partie1etC22.2No.0-M91**.
FixerunegainedeprotectiongurantdanslalisteU.L.
ouC.S.A.auxdeuxextrémitésducâblederaccordement,
àsavoirauniveaudel’appareiletauboîtieràfusibles.
Vouspouvezobtenirdescopiesdesnormesmentionnées
auprès de :
* National Fire Protection Association Batterymarch Park
Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575.
Page 18
Cotes de l’apparei
30" (762 mm)
36" (914 mm)
A
19
11
/
16
"
(500 mm)
7
7
/
8
"
(200 mm)
10
3
/
4
"
(273 mm)
13
3
/
16
"
(335 mm)
5¾"
(146 mm)
A Uniquement en cas de mode recirculation de l’air :
*Max. 43
1
2" (1106 mm)
*Min. 29" (734 mm)
Uniquement en cas de mode evacuation de l’air :
*Max. 39
1
2" (1006 mm)
*Min. 25" (633 mm)
Distances de sécurité
AVERTISSEMENT
RISQUE D’INCENDIE
Lesdépôtsdegraissedansleltreàgraissepeuvent
s’enammer.Ladistancedesécuritérecommandéedoit
êtrerespectéeand’éviteruneaccumulationdechaleur.
Veuillezrespecterlesspécicationsdevotreappareil
decuisson.Sidescuisinièresélectriquesetàgazsont
utiliséesensemble,laplusgrandedistanceindiquée
s’applique.
L’appareilpeutseulementêtreinstallédirectementcontre
unmurouunearmoiresuruncôté.
L’espacement du mur ou de l’armoire doit être d’au
moins 2” (50 mm).
La distance entre la surface de rangement sur la table de
cuisson et le dessous de la hotte ne doit pas être
inférieureà30”(760mm)pourlestablesdecuisson
électriquesetpourlescuisinièresàgazoucombinées.
Si les instructions pour l’installation de l’appareil de cuisson
augazspécientuneplusgrandedistance,cellecidoitêtre
prise en compte.
Tabledecuissonaugazetélectrique
min. 30" (762 mm)
Mode évacuation
Remarque: Ilnefautpasrejeterl’airusédansune
cheminéed’évacuationenservice,nidansunconduit
servantàlaventilationdepiècesoùsontinstallésdes
foyers.
Pourrejeterl’airdansunconduitdefuméesquin’est
pas en service, il faut demander l’accord du maître
ramoneurcompétent.
Sil’airestévacuéàtraverslemurextérieurde
l’habitation,ilfaututiliseruncaissonmuraltélescopique.
Conduit d’évacuation
Remarque:Lefabricantdel’appareildéclinetoutegarantie
encasderéclamationimputableàdesproblèmesliésau
parcours des conduits.
L’ouvertured’évacuationd’airetlesconduits
d’évacuationdoiventêtreexécutésenfonctiondes
conditions locales.
L’appareilatteindraunrendementsupérieursile
conduitd’évacuationestcourtetdroitetqueson
diamètre est grand.
Desconduitsd’évacuationd’airlongs,auxparois
rugueuses, comportant plusieurs coudes ou des
diamètres trop petits, empêchent d’atteindre une
puissance d’aspiration optimale et le ventilateur
devient plus bruyant.
Les tuyaux rigides ou souples constituant le conduit
d’évacuationdoiventêtreenmatériauininammable.
Lisser la zone de raccordement des tuyaux avant le
montage.
Étancher les zones de jonction.
Tuyaux ronds
NousrecommandonsundiamètreintérieurdeØ8”(200mm).
Vérifier le mur
Le mur doit être plat, vertical et offrir une portance
sufsante.
Laprofondeurdestrouspercésdoitêtreadaptéeàla
longueur des vis. Les chevilles doivent offrir une
retenuesûre.
Les vis et chevilles fournies conviennent pour la
maçonneriemassive.Enprésenced’autresmatériaux
deconstruction,ilfaututiliserdesmoyensdexation
correspondants.
Page 19
Longueurséquivalentesdeconduitespourpiècesdetransitionhabituellementutilisée
Taille
(po)
Taille
(po)
Longueur
équivalente
(pi)
Longueur
équivalente
(pi)
61.2
61
0
80.7
10 0.6
x 10 po, droit S.O. 1
S.O. 25
x 14 po, droit S.O. 0.7
S.O. 15
S.O. 25
612
62
86
82
10
10 2
65
62
2
5
83
82
2
2
10
10
x 10 po
coude 90 degrés, rond
S.O. 5
Gaine souple, 2 pi long,
3¼ x 10 po
S.O. 20
x 10 po,
coude 45 degrés, rond
S.O. 15
x 10 po,
coude plat
S.O. 20
61
810
82
Trémie de cheminée et
volet d’obturation,
3¼ x 10 po
S.O.
65
61
0
REMARQUE: Ces pièces courantes pour installation sont offertes dans
les quincailleries locales. Bosch ne fabrique pas toutes ces pièces.
Lisse, ronde
Lisse de toit, ronde
15S.O.
Orifice rond jusqu’à
x 10 po
x 10 po
jusqu’à l’orifice rond
Pièce du système Pièce du système
Lisse, droite
Coude 90 degrés,
rond
Coude 45 degrés,
rond
Orifice rond jusqu’à
3¼ x 10 po,
avec coude 90 degrés
3¼ x 10 po avec
coude de 90 degrés,
rond
3¼ x 10 po coude
centré, inversé,
gauche
3¼ x 10 po coude
centré, inversé,
droit
3¼ x 10 po coude à
gauche, inversé
3¼ x 10 po coude
droit, inversé
Procédure d’installation
Lesconduitsmenantdelahotteàl’extérieurdubâtiment
ont un impact important sur la circulation d’air, le bruit et la
consommationénergétiquedelahotte.Utilisezla
congurationdeconduitslapluscourteetlaplusdroite
possiblepourunrendementoptimal,etévitezd’installerla
hotte avec des conduits d’une taille plus petite que celle
recommandée.L’isolationautourdesconduitspeutréduire
laperteénergétiqueetprévenirlaformationdemoisissure.
Deshottesinstalléesavecdesconduitsdéjàenplace
peuventnepasatteindreleurdébitd’airnominal.
ATTENTION
Veillezàcequ’iln’yaitpasdeconduitesélectriques,
ou tuyaux de gaz et d’eau au niveau des perçages.
Ventilation
par le toit
Ventilation
murale
Aucune
ventilation*
(Recirculation)
A. Capuchon de toit
B. Conduit rond de
8 po (20,3 cm)
C. Sceller les joints
des conduits avec
du ruban adhésif/
produit calfeutrant
A. Capuchon mural
B. Conduit rond de
8 po (20,3 cm)
C. Sceller les joints
des conduits avec
du ruban adhésif/
produit calfeutran
A. Dériveur
B. Conduit rond de
8 po (20,3 cm)
C. Sceller les joints
des conduits avec
du ruban adhésif/
produit calfeutran
A
B
C
A
B
C
B
C
Page 20
Préparer l’installation
1. Duplafondaubordinférieurdelahotteaspirante,
tracerunelignemédianeverticalesurlemur.
2. Alignerlegabaritdeperçageàlalignemédianeetau
bordinférieurdelahotteetlecoller.
3. Marquer les emplacements des vis et le contour de la
zone d’accrochage.
4. Marquer les perçages pour les cornières de retenue de
lacheminée.Lemilieudescornièresderetenueest
repéréparunperçage.Appliquerlescornièresde
retenuedefaçoncentréeàlalignemédiane,lesaligner
horizontalement et marquer l’emplacement des
perçages.
B
C
A
A Toit
B Mur
C Axe centrale
Montage de la fixation murale
1. Percer les trous avec le foret de Ø 5/16” (7,9 mm)
pour la cornière de retenue.
2. Enfoncerleschevillesàeurdumur.
3. Visserlesvis(5x45mm)àlamaindansleschevilles,
and’écarterlacheville.
4. Dévisserlesvis.
5. Visserlacornièrepourlacheminée.
Percement du plafond
1. Prolongerlalignemédianedugabaritdeperçage
versleplafondàl’aided’unniveauàbulle.
2. Marquerleperçageduplafond(Ø81/2”(216mm))à
une distance d’au moins 4 5/8” (117 mm) du mur.
Percement du mur
1. Prolongerlalignemédianedugabaritdeperçagevers
leplafondàl’aided’unniveauàbulle.
2. En fonction du coude, marquer le perçage du mur
(Ø81/2”(216mm))àunedistanced’aumoins261/2”
(660mm)au-dessusdubordsupérieurdelahotte.
Montage du volet anti-refoulement
1. Installer l’entretoise de transition avec 4 vis de
4.2 x 8 mm.
Visserlevoletanti-refoulementsurlahotteàl’aidede
4 vis (4x8 mm).
A
B
A Entretoise de transition
B Transition d’air
Monter la hotte aspirante au mur
AVERTISSEMENT
RISQUE DE BLESSURE
L’appareilestlourd.2personnessontnécessairespour
déplacerl’appareil.Utiliserexclusivementdesmoyens
appropriés.
1. Retirerd’abordlelmprotecteurdudosdel’appareil,
puisintégralementunefoislemontageachevé.
2. Marquerlesperçagessupérieurssurlemur.
Remarque:S’assurerquelesperçagessontalignés
horizontalementetdemanièrecentréeàlaligne
médiane.
3. Percerlestroussupérieurs.Respecterunedistancede
1/4” (6 mm) entre le mur et la tête de la vis.
4. Enleverleltreàgraisse.
5. Accrocherlahotteaumurauxvissupérieures.
6. Marquerlesperçagesinférieurs.
7. Enlever la hotte du mur.
8. Percerlestrousinférieurs.
9. Accrocherlahotteaumurauxvissupérieures.
10. Serrerlesvissupérieuresetinférieuresàlamain.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Bosch HCP56652UC Guide d'installation

Taper
Guide d'installation
Ce manuel convient également à