Elster RABO Mode d'emploi

Taper
Mode d'emploi
Honeywell
730xxxxxx © Elster GmbH | All rights reserved. Subject to modification 1
English
Instruction Manual
Rotary gas meters
Type RABO®
Betriebsanleitung
Drehkolbengaszähler
Typ RABO®
Mode d’emploi
Compteurs de gaz à pistons rotatifs
Type RABO®
Manual de instrucciones
Contadores de gas de pistones rotativos
Modelo R.Abo®
Instruzioni d’uso
Contatori gas a pistoni rotanti
Tipo RABO®
Gebruiksaanwijzing
Rotorgasmeters
Type RABO®
Honeywell
2 730xxxxxx © Elster GmbH | All rights reserved. Subject to modification
Honeywell
730xxxxxx © Elster GmbH | All rights reserved. Subject to modification 3
English
Français
Español
Italiano
Nederlands
Deutsch
Instruction Manual
Rotary gas meters
Type RABO®
Betriebsanleitung
Drehkolbengaszähler
Typ RABO®
Mode d’emploi
Compteurs de gaz à pistons rotatifs
Type RABO®
Manual de instrucciones
Contadores de gas de pistones rotativos
Modelos R.Abo®
Instruzioni d’uso
Contatori gas a pistoni rotanti
Tipo RABO®
Gebruiksaanwijzing
Rotorgasmeters
Type RABO®
Honeywell
4 730xxxxxx © Elster GmbH | All rights reserved. Subject to modification
Honeywell
73021678h © Elster GmbH | All rights reserved. Subject to modification 5
English
RABO® G16 G400
RAB-CT/CF G10 G40
Instruction Manual
Rotary gas meters
Type RABO®
Honeywell
73021678h © Elster GmbH | All rights reserved. Subject to modification 7
English
Contents
1. Safety instructions ........................................................................................... 9
1.1 Intended use ............................................................................................... 10
1.2 Approvals and certifications .................................................................... 10
1.3 Copyright and data protection ................................................................ 11
1.4 Exemption from liability ........................................................................... 11
1.5 Product liability and guarantee .............................................................. 12
1.6 Personnel .................................................................................................... 12
1.7 Intended use and field of application .................................................... 12
1.8 Legal declarations ..................................................................................... 12
1.9 Recycling and environmental protection .............................................. 13
2. Structure and function .................................................................................. 14
2.1 Device description ..................................................................................... 15
2.2 Index versions ............................................................................................. 16
2.3 Temperature test points ........................................................................... 17
2.4 Pressure test points .................................................................................. 18
2.5 Pulse generators/Encoders .................................................................... 18
3. Installation and commissioning .................................................................. 19
3.1 Scope of delivery ........................................................................................ 19
3.2 Storage ......................................................................................................... 19
3.3 Transport ..................................................................................................... 20
3.4 Requirements to be met before installation ......................................... 20
3.5 Installation position and flow direction ................................................. 22
3.6 Installation .................................................................................................. 23
3.7 Commissioning/Filling with oil ............................................................... 24
4. Maintenance ................................................................................................... 25
4.1 Cleaning ...................................................................................................... 26
4.2 Repair/Removal ......................................................................................... 26
4.3 Disposal ....................................................................................................... 26
5. Technical data ................................................................................................. 27
5.1 Dimensions, weights and connections ................................................. 30
5.2 Ambient conditions ................................................................................... 31
5.3 Approvals ..................................................................................................... 32
6. Annex A Standards and Norms ................................................................. 33
7. Annex B Plastics used ................................................................................ 33
8. Annex C List of gas types ........................................................................... 34
Honeywell
8 73021678h © Elster GmbH | All rights reserved. Subject to modification
Information on the documentation
The latest version of the operating instructions is available to download from the
Honeywell website.
Please read the information in this document carefully in order to avoid injury to
the user or damage to the device. Moreover, currently valid national standards,
safety regulations and accident prevention regulations must be adhered to.
Should you have any problems understanding the contents of this document,
please contact your local Honeywell branch for support. Honeywell cannot
accept any responsibility for damage to property or personal injuries which are a
result of the information in this document not having been understood properly.
This document helps you to set up the operating conditions in such a way that
the safe and efficient use of the device is assured. In addition, this document also
specifies points and safety measures which must be particularly observed and
which are indicated using the following symbols:
This symbol warns of dangerous situations. Failure to follow the
environment or the meter could suffer damage.
Accurate measurement cannot be ensured if information or
notes with this symbol are ignored.
Honeywell
73021678h © Elster GmbH | All rights reserved. Subject to modification 9
English
1. Safety instructions
WARNING!
Danger of electrostatic discharge only use a damp cloth to clean.
WARNING!
If there is danger that the device can be damaged from falling
(pointed, sharp-edged or heavy) objects, the operator must protect
the device.
WARNING!
Exposure to danger which can result from a chemical reaction
between parts of the meter and chemical substances in the vicinity
must be discussed with the manufacturer and the cause must be
eliminated.
WARNING!
The meter must be included in the equipotential bond by
connecting it to the grounded pipeline.
WARNING!
If you wish to add odorants or use solenoid valves, please always fit
them downstream of the meter only. Otherwise, the device may be
damaged.
WARNING!
The gas must not contain suspended particles > 50 µm. In
addition, the gas must be dry. Otherwise, the meter may be
damaged.
INFORMATION!
The flow through the meter must be free of vibrations and
pulsations in order to avoid measuring errors.
INFORMATION!
Compliance with the specified operating and ambient conditions
as indicated on the type label is absolutely essential for safe
operation of the meter and additional equipment.
Honeywell
10 73021678h © Elster GmbH | All rights reserved. Subject to modification
1.1 Intended use
CAUTION!
Responsibility for the use of the meter in terms of suitability,
intended use and the corrosion resistance of the materials to the
medium is solely in the hands of the operator.
INFORMATION!
The manufacturer shall not be liable for damage cause
d by
improper or inappropriate use.
1.2 Approvals and certifications
Marking / Declaration of conformity*
The manufacturer certifies conformity with the EU
declaration of conformity and by attaching the CE marking.
The measuring instrument meets the statutory
requirements of the relevant EU Directives.
Comprehensive information on the applicable EU
Directives and Standards, as well as recognized
certifications, is contained in the EU declaration of
conformity.
The EU declaration of conformity is included in the delivery
and is also available to download at www.docuthek.com.
See chapter 5.3 Approvals and Annex A
Standards and Norms, for details of other
approvals and Directives.
ATEX/IECEx
DANGER!
The rotary gas meter is suitable for use in Zone 1 hazardous
areas and is approved with the following certification (IECEx)
and manufacturer’s declaration (ATEX):
II 2G Ex h IIC T4 Gb
IECEx TUR 16.0042X (IECEx)
557/Ex-Ab 2664/16 (ATEX)
TÜV Rheinland Industrieservice GmbH
Am Grauen Stein | 51105 Köln | Germany
* The marking on the device shall be applicable.
Honeywell
73021678h © Elster GmbH | All rights reserved. Subject to modification 11
English
1.3 Copyright and data protection
This document has been created with the greatest possible care. No liability
is assumed for the accuracy, completeness or currency of the contents.
The contents and works produced in this document are subject to copyright.
Contributions by third parties are identified as such. The reproduction,
processing, distribution and any form of use beyond that which is permitted
by copyright require the written authorization of the respective author or the
manufacturer. The manufacturer strives to always respect the copyright of
others or to use his own or licence-free works.
We would like to point out that data transfer via the Internet (e.g. through e-
mail communication) can be subject to breaches in security. It is not
possible to provide complete protection against access by third parties.
1.4 Exemption from liability
The manufacturer shall not be liable for damage of any type caused by the
use of this product, including but not restricted to, direct, indirect or
incidental damage and its consequences.
This exemption from liability does not apply if the manufacturer has acted
intentionally or with gross negligence. In the event that any applicable law
does not allow such restrictions on implied warranties for defects, or the
exclusion or limitation of certain payments for damages, and should such
law apply to you, the above-mentioned exemption from liability, exclusions
or limitations may not apply to you in part or in whole.
For every product purchased, the warranty is valid in accordance with the
corresponding product documentation as well as the conditions of sale and
delivery of the manufacturer.
The manufacturer reserves the right to amend without prior notice the
contents of the documents, including this exemption from liability, in any
form and at any point in time, and for any reason, and shall in no way be liable
for any possible consequences of such amendments.
Honeywell
12 73021678h © Elster GmbH | All rights reserved. Subject to modification
1.5 Product liability and guarantee
The responsibility as to whether the measuring instrument is suitable for the
intended use is that of the operator. The manufacturer cannot accept any
liability for the consequences of misuse by the operator. Improper
installation or operation of the measuring instruments (systems) will render
the warranty void. Furthermore, the relevant “General Terms and Conditions”
which form the basis of the purchase contract also apply.
1.6 Personnel
This manual is aimed at personnel who have adequate specialist and
technical knowledge (in Germany, for instance, in accordance with DVGW
Codes of Practice 492 and 495 or comparable technical regulations) on the
basis of their training and experience in the sector of energy and gas
distribution.
1.7 Intended use and field of application
This product is intended to be used for the calibratable volumetric metering
of
flammable gases: natural gas/propane/butane
non-flammable gases: air/nitrogen/inert gases
Other areas of application or media, see Annex C List of gas types or
on request
This product is not intended for
metering aggressive gases, e.g. biogas or sewage gases, oxygen or
acetylene.
1.8 Legal declarations
The metrological conformity assessment is based on the regulations of
the country concerned, in which the measuring instrument will be used.
The period of validity of calibration is based on the regulations of the
country concerned, in which the measuring instrument will be used.
Honeywell
73021678h © Elster GmbH | All rights reserved. Subject to modification 13
English
1.9 Recycling and environmental protection
Honeywell has designed the transport packaging of the measuring
instrument to be environmentally friendly. Packaging materials are always
selected consistently with a view to recycling. The cardboard items used
constitute secondary raw materials for the paperboard and paper industry.
The Instapak® foam packaging is recyclable and can be reused.
Plastic sheeting and strips/bands are also made of recyclable plastic. At
Honeywell, subsequent recycling and disposal are already elements of the
product development process. When selecting the materials, we allow for
reusability of the materials, suitability of materials and subassemblies for
dismantling and separation, and the risks of environmental pollution and
health risks when recycling and dumping on landfill sites. The measuring
instruments mainly consist of metallic materials which can be melted down
again in steelworks and metallurgical plants and which can thus be reused a
virtually unlimited number of times. The plastics used are listed in Annex B
to ensure that the materials can be sorted and separated for the purposes of
subsequent recycling. Like all mineral oils (e.g. for motor vehicles), the oil
supplied with the device must be disposed of in an environmentally sound
way.
Honeywell
14 73021678h © Elster GmbH | All rights reserved. Subject to modification
2. Structure and function
Operating principle
Rotary gas meters are volume-measuring devices for gaseous media which
operate according to the positive displacement principle. Due to their
volumetric measuring principle, their functioning is not influenced by the
installation and they are therefore ideal for compact measuring systems
without an inlet section. They record the gas volume at operating conditions
and are approved for custody transfer applications. Electronic volume
conversion devices can be used in order to convert the volume.
Measurement procedure
Two rotating impellers which look like a figure of eight when viewed in cross-
section are mounted in a single housing with one inlet and one outlet (see
Fig. 1). The two impellers are coupled together using synchronizing gears.
When gas flows, the impellers rotate without touching one another and
propel a gas volume to the outlet which is defined by the cyclic volume. One
rotation of the system thus corresponds to a defined gas volume. The
revolutions of the impellers are transferred to the mechanical index via a
reducing gear and a magnetic coupler. The rotary gas meter is adjusted
using a pair of gears in the index.
Fig. 1b | Working principle of rotary gas meters
Fig. 1a | Working principle of rotary gas meters
Housing
Inlet
Outlet
¼ cyclic volume
Impeller
Synchronizing gears
Honeywell
73021678h © Elster GmbH | All rights reserved. Subject to modification 15
English
2.1 Device description
1
Meter housing
6
LF pulse generator (optional)
2
Housing cover (front)
7
HF pulse generator (optional)
3 Housing cover (rear) 8 Temperature test point(s)
4
Pistons
9
Pressure test point
5
Index
10
Oil-level gauge glass (optional)
Please contact your local Honeywell Customer Service Centre for assistance
in commissioning, maintenance and installation of encoders, pulse
generators and volume conversion devices for instance. Repairs may be
carried out only by authorized workshops.
Fig. 2 | RABO® rotary gas meter
1
2
3
4
5
6
7
8
9
10
Honeywell
16 73021678h © Elster GmbH | All rights reserved. Subject to modification
2.2 Index versions
The meter can be equipped with various index versions:
Index type code:
xxx x xxx
Property:
S1
S1V
S1D
S2
S2V
S2D
MI-2
MI-2D
Mechanical roller index, 8-digit
-
-
-
2 x mechanical roller index, 8-digit1)
-
-
-
-
-
Index, can be turned through 355°
Protection class IP 67
45° reading
-
-
-
-
-
Vertical reading
-
-
Connection for external
pulse generator IN-S
or IN-W
- - -
Suitable for internal pulse generator IN-Cxx
-
-
-
-
-
S1xR internal reed contact pulse generator
-
-
-
Optional: mechanical index drive
-
-
-
-
-
-
-
Optional: desiccant cartridge
-
-
-
-
-
-
Optional: ENCODER S1
-
-
-
Table 1 | Overview of the various index versions
1) One index is covered depending on the installation position.
Model version:
S1: plastic version 1
S2: plastic version 2
MI2:
aluminium
Type:
V: vertical reading
D: double index
“ ”: 45° reading
Extensions:
R: integrated pulse generator E1
R3: integrated pulse generator 2xE1
C11: integrated pulse generator IN-
Fig. 3 | Index examples (left: S1D, centre: S1V, right: S2)
Honeywell
73021678h © Elster GmbH | All rights reserved. Subject to modification 17
English
SxD index:
Indexes S1D and S2D feature two roller indexes. A hinged plate covers one
of the roller indexes and at same time shows the flow direction.
Changing the flow direction:
Unscrew the two front screws.
Fold the plate down.
Resecure the plate with the screws.
2.3 Temperature test points
A maximum of two temperature sensors may be used to measure the gas
temperature in the meter housing (see Fig. 5).
If no temperature test points are provided in the meter housing, external
temperature measurements must be taken in the pipe upstream of the gas
meter at a distance of up to 2 x DN.
Fig. 5 | Temperature and pressure test points
Fig. 4 | Hinged plate for flow direction
Thermowells for
temperature test points
Pressure test points
Honeywell
18 73021678h © Elster GmbH | All rights reserved. Subject to modification
NOTE!
In outdoor measuring systems, the result of measurement may
be influenced by the ambient temperature.
Insulate measuring elements outside the pipe adequately to
prevent ambient temperature influences.
Fill the thermowell(s) with a heat-conductive fluid or paste to
achieve optimum thermal conduction.
2.4 Pressure test points
A straight male coupling which complies with DIN 2353 is provided on the
meter housing to act as a pressure test point, for example to connect a
pressure sensor. It is marked pm/pr and is designed for connecting Ø 6 mm
steel tubes to DIN EN 10305-1 (e.g. steel grade E235) or flexible pressure
tubes from Honeywell.
CAUTION!
Danger to functional safety!
Functional safety and reliability are ensured only if the material
combination of the union component and the pipe are
intermatched.
The straight male coupling must not be connected to pipes
made of stainless steel or pipes made of non-ferrous materials.
NOTE!
Only use original Parker-Ermeto or Voss pipe unions.
We recommend that you contact our local Honeywell Customer
Service Centre for conversion work and when installing
additional devices.
2.5 Pulse generators/Encoders
The meter may be fitted with the following pulse generators or encoders:
Device type:
Manufacturer:
Device designation:
Low-frequency pulse generator (LF)
Elster GmbH
IN-Sxx
Low-frequency pulse generator (LF)
Elster GmbH
IN-Cxx
Low-frequency pulse generator (LF)
Elster GmbH
S1xRx
High-frequency pulse generator (HF)
Pepperl & Fuchs
SJ2-N
Encoder
Elster GmbH
ENCODER S1
Table 2 | Overview of pulse generators
Further information on the pulse generators and encoders is provided in
the separate instruction manuals.
Honeywell
73021678h © Elster GmbH | All rights reserved. Subject to modification 19
English
3. Installation and commissioning
INFORMATION!
Check the packing list to ensure that you have received your
complete order. Check the type labels to ensure that the device
supplied is the one you ordered.
INFORMATION!
Check the packaging carefully for signs of damage or signs that
the device has been handled incorrectly. Report any damage to the
forwarding agent and to the local representative of the
manufacturer.
INFORMATION!
The installation material and tools are not supplied with the device.
Use installation material and tools which comply with current
health and safety regulations.
3.1 Scope of delivery
Ordered measuring instrument
Instruction manual
Product documentation
Oil Shell Morlina S2 BL 10 or Molyduval Chemlube 315
Syringe and hose
Optional accessories depending on the purchase order
Optional: calibration certificate
3.2 Storage
Store the device in a dry and dust-free location.
Avoid constant direct sunlight.
Store the device in its original packaging.
Storage temperature: -40 to +70°C / -40 to +158°F.
Honeywell
20 73021678h © Elster GmbH | All rights reserved. Subject to modification
3.3 Transport
INFORMATION!
Do not lift the measuring instrument by the index.
INFORMATION!
Always use the lifting lugs (see Fig. 6) for transporting large rotary
gas meters.
3.4 Requirements to be met before installation
Remove sealing caps and foils.
Check the meter and accessories for signs of
transport damage.
Check that the impellers in the measuring
chamber move easily by generating a gentle air
current.
Ensure that you have all the tools you require
available.
Seals which are suitable for your operating
medium.
Screws according to ISO 4014 (see Fig. 7 and Table 3)
Fig. 7 | Thread reach C
Fig. 6 | Lifting lugs
Lifting lugs
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196

Elster RABO Mode d'emploi

Taper
Mode d'emploi