IMPORTANT INSTRUCTIONS - OPERATING MANUAL
INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION
SAVE THESE INSTRUCTIONS
Range Hood
Hotte de cuisinière
Series / Séries AV, AVR
READ AND SAVE THESE
INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL,
OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock and injury to person, including the following:
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have questions, contact the
manufacturer.
b) Before servicing or cleaning the unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag,
to the service panel.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all
applicable codes and standards, including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
CAUTION: TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST
AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT VENT EXHAUST AIR INTO SPACES
WITHIN WALLS OR CEILINGS OR INTO ATTICS, CRAWL SPACES, OR GARAGES.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING: TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boil overs cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambéing food (ie. Crepes Suzette,
Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan filter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off burner. BE
CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
LIRE ET CONSERVER
CES INSTRUCTIONS
LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER,
OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME
ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ.
FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN
BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À LA PROPRIÉTÉ.
CONSERVER CES INSTRUCTIONS POUR RÉFÉRENCES FUTURES.
INSTRUCTIONS GÉNÉRALES DE SÉCURITÉ
Lors de l’utilisation d’appareils électriques, des
précautions de base doivent toujours être suivies pour
réduire les risques d’incendie, de choc électrique et de
blessures corporelles, incluant ce qui suit:
AVERTISSEMENT : POUR RÉDUIRE LES RISQUES
D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES PERSONNELLES
OBSERVER CE QUI SUIT:
a) Utiliser cette unité seulement de la manière pour laquelle le fabricant l’a conçu. Si vous aviez des
questions, veuillez contacter le fabricant.
b) Avant d’effectuer un service ou de nettoyer l’unité, couper l’alimentation électrique dans le
panneau de distribution et verrouiller le dispositif de déconnexion afin d’éviter que l’alimentation
ne revienne accidentellement. Lorsque le dispositif ne peut être verrouillé, fixer solidement un avis
d’avertissement, tel qu’une étiquette, au panneau de distribution.
AVERTISSEMENT : POUR RÉDUIRE LES RISQUES
D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES PERSONNELLES
OBSERVER CE QUI SUIT:
a) Le travail d’installation et le câblage électrique doivent être effectués par une(des) personne(s) qualifiée(s)
en conformité avec tous les codes et normes applicables, incluant la construction relative aux incendies.
b) De l’air en quantité suffisante est requis pour la bonne combustion et l’évacuation de gaz par le
conduit (cheminée) provenant d’équipement de brûlage au combustible pour prévenir un refoulement.
Suivre les directives du fabricant de l’équipement de chauffage et les normes de sécurité telles que
celles publiées par la National Fire Protection Association (NFPA) et de la American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), et de celles des autorités locales du code.
c) Lors de coupe ou de perçage des murs et plafonds, ne pas endommager le filage électrique et
autres utilités cachées.
ATTENTION : POUR USAGE DE VENTILATION GÉNÉRALE
EXCLUSIVEMENT. NE PAS UTILISER POUR ÉVACUER DU MATÉRIEL ET DES
VAPEURS DANGEREUSES OU EXPLOSIVES.
AVERTISSEMENT : POUR USAGE DE VENTILATION
GÉNÉRALE EXCLUSIVEMENT. NE PAS UTILISER POUR ÉVACUER DU MATÉRIEL ET
DES VAPEURS DANGEREUSES OU EXPLOSIVES.
d) Les ventilateurs avec conduits doivent toujours être évacués vers l’extérieur
e) Cette unité doit être mise à la terre
f) Pour éviter des dommages aux roulements des moteurs et/ou des hélices bruyantes ou déséquilibrées,
empêcher la poussière de cloison sèche, poussière de construction, etc., d’atteindre l’unité de puissance.
g) Lire toutes les instructions avant d’installer ou d’utiliser la ventilateur.
AVERTISSEMENT : POUR RÉDUIRE LES RISQUES
D’INCENDIE OU DE CHOC ÉLECTRIQUE, NE PAS UTILISER CE VENTILATEUR
AVEC UN RÉGULATEUR DE VITESSE ÉLECTRONIQUE.
AVERTISSEMENT : POUR RÉDUIRE LES RISQUES
D’INCENDIE DE GRAISSE SUR LE DESSUS DE LA CUISINIÈRE:
a) Ne jamais laisser les unités de surface à des degrés élevés sans surveillance. Les
débordements par bouillonnement produisent de la fumée et des débordements graisseux
qui peuvent s’enflammer. Chauffer les huiles lentement à des degrés faibles ou modérés.
b) Toujours mettre la hotte EN MARCHE lors de cuisson à haute température ou lors de
flambage de nourriture (par ex., des Crêpes Suzette, de Cerises Jubilées, steak flambé, etc.)
c) Nettoyer les ventilateurs d’évacuation fréquemment. Aucune accumulation de graisse ne
devrait être tolérée sur les filtres du ventilateur.
d) Utiliser des poêlons de taille appropriée. Toujours utiliser les batteries de cuisine appropriées
pour la taille de l’élément de surface.
AVERTISSEMENT : POUR RÉDUIRE LES RISQUES DE
BLESSURES PERSONNELLES DANS L’ÉVENTUALITÉ D’UN FEU DE GRAISSE SUR LA
SURFACE DE CUISSON, SUIVRE LES INDICATIONS SUIVANTES:
a) ÉTOUFFER LES FLAMMES avec un couvercle bien ajusté, une tôle à biscuits, ou un cabaret de
métal, puis, mettre le gril hors fonction. PRENEZ SOIN D’ÉVITER LES BRÛLURES. Si les flammes
ne s’éteignent pas immédiatement, ÉVACUER ET APPELER LE SERVICE DES INCENDIES.
c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.
d) Use an extinguisher ONLY if:
I. You know you have a Class ABC extinguisher, and you already know how to operate it.
II. The fire is small and contained in the area where it started.
III. The fire department is being called.
IV. You can fight the fire with your back to an exit.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
INSTALLATION INSTRUCTIONS
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL
BEFORE STARTING INSTALLATION.
SECTION 1
Preparing the Range Hood
1. Unpack hood from the carton and confirm that all pieces are present. In addition to the range hood
you should have:
1 - Aluminum Grease Filter 1 - 3-1/4"x 10" Damper
3 - Damper Mounting Screws 1 - 7" Round Damper Assembly (AVR Serires)
4 - #8 Mounting Screws 1 - Wire Compartment Cover and Screw
1 - Instruction/Safety Sheet
NOTE: Some hoods may be shipped with a protective plastic adhered to the
range hood. It is recommended to leave this in place during installation to
protect the hood from scratching. Remove when the installation is complete.
2. Lay the hood flat on a table so the underside is facing you. Use a piece
of cardboard to avoid damaging the table or the hood.
3. Remove lamp cover by squeezing the two tabs together (Figure 1).
4. Install a 60 watt maximum type A19 bulb and reinstall the lamp cover.
SECTION 2
Prepare the location for Hood Support
1. If the hood will be installed under cabinets that have a recessed bottom, it
will be necessary to install wood mounting strips (not included) so the hood
will mount properly (Figure 2).
2. The thickness of the strips should be the same as the recess of the
cabinet and they should be approximately 2" wide.
3. Install the strips using appropriate length wood screws (not included).
Make sure the strips line up to the keyhole slots of the range hood.
SECTION 3
Prepare the Hood for Installation
1. Choose the type of ducting you will require. This model is equipped to
vent either Vertically or Horizontally through a 3-1/4" x 10" duct. It can
be modified to be ductless (re-circulates the air back into the kitchen)
with the addition of a model RF55 combination grease/charcoal filter
(not included) or vented through a 7" round duct with the addition of a
model RDC7 Duct Collar (included with AVR series ONLY) (Figure 3).
2a. Horizontal or Vertical - Remove the square knockout by inserting a
screw driver under the edge and break the tabs holding it in place. Peel
back with pliers (Figure 4).
2b. Ductless - Remove the hood’s front louver cover, exposing the front
air slots. To remove louver slide to one side and lift the trailing edge.
Do not use a screwdriver or any other object that could scratch
the hood (Figure 4).
2c. 7" Round - Remove the round knockout located on the top of the
hood by inserting a screw driver under the edge and break the
tabs holding it in place. Peel back with pliers (Figure 4).
3. Determine where the electrical service will enter the hood and
remove the appropriate electrical knockout by inserting a screw
driver into the slot and rocking back and forth until the knockout
comes loose (Figure 4).
SECTION 4
Installing the Range Hood
CAUTION: MAKE SURE POWER IS
SWITCHED OFF AT SERVICE PANEL BEFORE STARTING
INSTALLATION.
1. Once the proper knockout(s) have been removed, either hold the
hood up to the installation location and mark the locations of the
ducting (if applicable), electrical, and mounting holes or mark the
locations by measurement.
2. Cut appropriate holes for ducting connection (if applicable) and
electrical connection in the wall/cabinet.
3. For 3-1/4" x 10" vertical or horizontal ducting, install the damper
assembly to the hood by sliding the tabbed section of the damper
under the hood body and securing with the two provided screws.
For 7" round ducting, secure with a model RCD7 Duct Collar (included with AVR series ONLY) to the
hood with the three provided screws. Using approved duct tape, tape around the collar to seal off
any air leaks (Figure 5).
www.airkinglimited.com
6728002 Rev. P 9-19 2 of 4
Figure 2
Wood Strip
Tabs
Figure 1
Tab
Figure 5
Damper
Hood Body
RCD7
Ductless
Figure 3
Horizontal
Vertical
Figure 4
Horizontal Vertical Ductless
b) NE JAMAIS SAISIR UN POÊLON EN FLAMME – vous pourriez être brûlé.
c) NE PAS UTILISER DE L’EAU, incluant les linges à vaisselle ou les serviettes mouillées – il en
résulterait une violente explosion de vapeur.
d) Utiliser un extincteur SEULEMENT SI:
I. Vous savez que vous avez un extincteur de classe ABC, et que vous savez déjà
comment l’opérer.
II. Le feu est petit et contenu dans la zone où il a commencé.
III. On appelle le service des incendies.
IV. Vous pouvez combattre l’incendie avec une sortie derrière vous.
AVERTISSEMENT : POUR RÉDUIRE LES RISQUES
D’INCENDIE, UTILISER UNIQUEMENT DES CONDUITS EN MÉTAL.
INSTRUCTIONS D’INSTALLATION
ATTENTION : ASSUREZ-VOUS QUE L’ALIMENTATION ÉLECTRIQUE
EST COUPÉE À PARTIR DU PANNEAU DE DISTRIBUTION AVANT DE COMMENCER
L’INSTALLATION.
SECTION 1
Préparation de la hotte de cuisinière
1. Sortez la hotte de l’emballage et assurez-vous d’avoir toutes les pièces. En plus de la hotte, vous
devriez avoir :
1 - Filtre à graisse en aluminium 1 - Clapet de 8,25 x 25,4 cm (3-1/4 po x 10 po)
3 - Vis de montage de clapet 1 - Assemblement de Clapet de rond 7 po (Serie AVR)
4 - Vis de montage #8 1 - Couvercle du compartiment de câblage et vis
1 - Feuille d’instructions/ sécurité
REMARQUE : Certaines hottes peuvent être expédiées avec un plastique
protecteur collé sur la hotte. Il est recommandé de la laisser en place durant
l’installation pour protéger la hotte contre les égratignures. L’enlever lorsque
l’installation sera complétée.
2. Déposez la hotte à plat sur la table de manière à ce que la partie
inférieure soit face à vous. Placez un morceau de carton en dessous afin
d’éviter d’endommager la table ou la hotte.
3. Enlever le couvercle de lampe en pressant les deux onglets ensemble
(Figure 1):
4. Installer une ampoule de type A19 d’un maximum de 60 watts et
réinstaller le couvercle de lampe.
SECTION 2
Préparez l’emplacement du support de la hotte.
1. Pour installer la hotte sous des armoires dont la base est en retrait, il faut
d’abord installer des bandes de fixation en bois (non comprises) afin que la
hotte soit fixée convenablement (Figure 2).
2. L’épaisseur des bandes doit correspondre au retrait de l'armoire et doit
avoir une largeur d'environ 5 cm.
3. Posez les bandes à l’aide de vis à bois (non comprises) de longueur
appropriée. Assurez-vous que les bandes sont alignées aux encoches en trou
de serrure de la hotte.
SECTION 3
Préparez la hotte pour l’installation
1. Choisir le type de conduits qui sera requis. Ce modèle est équipé pour
souffler tant verticalement qu’horizontalement dans un conduit de 8,25 x
25,4 cm (3-1/4 po x 10 po). Il peut être modifié pour devenir sans conduit
(recirculation de l’air dans la cuisine) avec l’addition d’un filtre combiné
graisse/ charbon modèle RF55 (non inclus) ou soufflé au travers d’un
conduit rond de 17,78 cm (7 po) avec l’addition d’un clapet modèle RDC7
(inclus avec la série AVR SEULEMENT) (Figure 3).
2a. Horizontal ou Vertical - Enlever l’alvéole défonçable en insérant un
tournevis sous le contour et casser les attaches qui le retiennent en
place. Peler avec des pinces (Figure 4).
2b. Sans Conduit - enlever le cache persienne, exposant les fentes
à air à l’avant. Pour enlever les persiennes glisser vers un côté et
soulever le flanc arrière. Ne pas utiliser de tournevis ou autre objet qui
pourrait endommager la hotte (Figure 4).
2c. Rond de 17,78 cm (7 po) - enlever l’alvéole défonçable située sur
le dessus de la hotte en insérant un tournevis sous le rebord et briser les
attaches qui la maintiennent en place. Peler avec des pinces (Figure 4).
3. Déterminer où le service électrique entrera dans la hotte et enlever
les alvéoles défonçables électriques appropriées en insérant un
tournevis dans la fente et en en le repliant vers l’avant et l’arrière
jusqu’à ce que les alvéoles deviennent lâches (Figure 4).
SECTION 4
Installation de la hotte
ATTENTION : ASSUREZ-VOUS QUE
L’ALIMENTATION ÉLECTRIQUE EST COUPÉE À PARTIR
DU PANNEAU DE DISTRIBUTION AVANT DE COMMENCER L’INSTALLATION.
1. Une fois que la (les) bonne(s) alvéole(s) a(ont) été enlevée(s), au choix,
tenir la hotte à l’emplacement d’installation et marquer les endroits
appropriés des trous pour les conduits (si applicable), l’électricité et de
montage ou encore, marquer les emplacements en les mesurant.
2. Couper les trous appropriés pour le raccordement des conduits (si
applicable) et électrique dans le mur/ l’armoire.
3. Pour un conduit vertical ou horizontal de 8,25 x 25,4 cm (3-1/4 po x 10 po), installer l’assemblage de clapet
à la hotte en glissant la section à onglets du clapet sous le corps de la hotte et en vissant les deux vis
fournies. Pour un conduit rond de 17,78 cm (7 po), fixer un clapet modèle RCD7 (inclus avec la série AVR
4. Install an approved wire connector to the electrical knockout of the
hood and guide the electrical cable through the hood, allowing at
least 6" of wire for connections and tighten.
NOTE: If installing into existing construction and you will not have
access to the ductwork once the hood is in place, make ducting
connections at this point. Refer to the Ducting Section for instructions.
5. Install the 4 mounting screws at the previously marked locations.
Leave approximately 1/8" clearance. Slide the hood in place through
the keyhole slots and align the front of the hood so that it is flush
with the front of the cabinets. Tighten all screws securely (Figure 6).
CAUTION: DO NOT INSTALL CLOSER THAN 22
INCHES ABOVE COOKING SURFACE.
SECTION 5
Wiring
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN
ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL
CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE
SERVICES OF A QUALIFIED ELECTRICIAN.
1. Connect the 2 loose White wires from the range hood to the White
wire from the supply, and the loose Black wire from the range
hood to the Black wire of the supply. Connect the ground wire
(green or bare) from the supply to the green ground screw of the
hood. Use approved methods for all connections (Figure 7).
NOTE: DO NOT disconnect any wiring that has already been crimped
with a wire connector from the factory.
2. Install the wire compartment cover and tighten screw. Make sure
all wiring is securely contained within the wire compartment.
SECTION 6
Ducting
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL
AND NATIONAL BUILDING CODES.
WARNING: TO REDUCE THE RISK OF FIRE,
USE ONLY METAL DUCTWORK.
1. Connect the ducting to the hood’s duct collar and damper. Secure in place
using tape to seal all joints (Figure 8).
CAUTION: ALWAYS DUCT THE FAN TO THE OUTSIDE
THROUGH A WALL OR ROOF CAP.
SECTION 7
Finishing the Installation
1. Install the appropriate filter sliding the back side of the filter into
the tab and pressing the front of the filter into place (Figure 9).
2. Turn switches to the “OFF” position and restore power. Test that
the light and the fan are operating properly.
3. If there is any vibration noise, check for the source and try to
tighten fasteners.
SECTION 8
Operation
Your Range Hood is equipped with two rocker style switches with one
controlling the lighting and the other controlling the exhaust fan. The light switch has two positions, ON ( I )
and OFF ( II ). The fan is a three position switch, HIGH ( II ), LOW ( I ), and OFF. OFF is the middle position of
the switch.
SECTION 9
Maintenance
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL
BEFORE SERVICING THE UNIT.
Filters
Grease Filter - Included with your range hood is an aluminum grease filter that should be washed in hot
water with detergent once a month. Reverse the instructions in the “Finishing the Installation” section of
the instructions to remove filter. If the grease filter becomes damaged, replace with Air King Model RF35
Grease Filter.
Charcoal Odor Filter - If you have installed an optional combination grease/charcoal filter, it cannot be
washed and must be discarded and replaced when it becomes noticeably dirty, has stopped filtering the
odors, or at least once per year. Replace with Air King Model RF55 Combination Odor/Grease Filter.
Cleaning
CAUTION: DO NOT USE GASOLINE, BENZINE, THINNER, HARSH CLEANSERS,
ETC., AS THEY MAY DAMAGE THE RANGE HOOD.
1. Clean your range hood with a mild detergent, such as dishwashing liquid, and dry with a soft cloth.
NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry before restoring power.
NEVER IMMERSE ELECTRICAL PARTS IN WATER.
2. The fan assembly can be vacuumed when build up (dirt, lint, etc.) accumulates over time. The fan is
permanently lubricated and does not require oiling.
www.airkinglimited.com
6728002 Rev. P 9-19 3 of 4
Figure 6
1/8"
Keyhole
Figure 9
Figure 8
SEULEMENT) à la hotte avec les 3 vis fournies. À l’aide de ruban adhésif
approuvé, appliquez autour du col pour sceller les fuites d'air (Figure 5).
4. Installer un connecteur de filage approuvé à l’alvéole pour l’électricité
de la hotte et guider les câbles électriques au travers de la hotte, en
laissant au moins 15,24 cm (6 po) de fil pour le raccordement puis serrer.
REMARQUE : Si installation dans une construction existante et que
vous n’aurez pas accès aux conduits une fois que la hotte sera en
place, faire les raccords des conduits à ce point. Référez-vous à la
section des Conduits pour les instructions.
5. Installer les 4 vis de montage aux endroits marqués précédemment.
Laisser un dégagement d’environ 0,33 cm (1/8 po). Glisser la hotte en
place au travers des trous en poire et aligner le devant de la hotte pour
qu’il soit à effleurement avec le devant des armoires. Visser fermement toutes les vis (Figure 6).
ATTENTION : NE PAS INSTALLER À MOINS DE 22 POUCES AU-DESSUS LA
SURFACE DE CUISSON.
SECTION 5
Câblage
ATTENTION : TOUTES LES CONNEXIONS ÉLECTRIQUES DOIVENT
ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX, AUX RÈGLEMENTS LOCAUX
OU AU CODE NATIONAL DE L'ÉLECTRICITÉ. SI LES MÉTHODES POUR INSTALLER DES
CÂBLAGES ÉLECTRIQUES NE VOUS SONT PAS FAMILIÈRES, FAITES
APPEL AUX SERVICES D’UN ÉLECTRICIEN QUALIFIÉ.
1. Connecter les deux fils lâches Blancs de la hotte de cuisine au fil Blanc
de l’alimentation, et le fil lâche Noir de la hotte au fil Noir de l’alimentation.
Connecter le fil de mise à la terre (vert ou dénudé) de l’alimentation à la
vis verte de mise à la terre de la hotte. Utiliser des méthodes de connexion
approuvées pour toutes les connexions (Figure 7).
REMARQUE : NE PAS déconnecter quelque fil qui ait déjà été serti avec
un connecteur de fil à l’usine.
2. Placez le couvercle du compartiment de fils et serrez la vis. Assurez-vous que
tous les fils sont placés de manière sécuritaire à l’intérieur du compartiment.
SECTION 6
Conduits
ATTENTION : TOUS LES CONDUITS DOIVENT ÊTRE
CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX.
AVERTISSEMENT : POUR RÉDUIRE
LES RISQUES D’INCENDIE, UTILISER UNIQUEMENT DES
CONDUITS EN MÉTAL.
1. Raccorder les conduits au collet et au clapet de la hotte. Fixer en place en
utilisant du ruban pour canalisations pour sceller tous les joints (Figure 8).
ATTENTION : TOUJOURS PASSER LES
CONDUITS DU VENTILATEUR VERS L’EXTÉRIEUR EN
UTILISANT UN CAPUCHON MURAL OU DE TOIT.
SECTION 7
Finition de l’installation
1. Installer les filtres en ajustant le filtre dans le canal de la hotte et en
le glissant vers l’arrière jusqu’à ce qu’il soit arrêté contre l’arrière de
la hotte (Figure 9).
2. Mettre les interrupteurs en position « HORS (OFF) » et rétablir
l’alimentation. Tester que la lampe et le ventilateur fonctionnent
correctement.
3. S’il y a un bruit de vibration, recherchez-en la source et essayez de
serrer les attaches ou d’ajuster le ruban pour canalisations pour faire
un raccord ou un scellant plus serré.
SECTION 8
Opération
Votre Hotte de Cuisine est équipée de deux interrupteurs à type basculant dont l’un contrôle l’éclairage et
l’autre le ventilateur. L’interrupteur de la lampe a deux positions, EN ( I ) et HORS ( II ). Le ventilateur a un
interrupteur à trois positions, HAUT ( II ), BAS ( I ) et HORS. HORS est la position médiane de l’interrupteur.
SECTION 9
Entretien
ATTENTION : ASSUREZ-VOUS QUE L’ALIMENTATION ÉLECTRIQUE
EST COUPÉE À PARTIR DU PANNEAU DE DISTRIBUTION AVANT DE COMMENCER
L’INSTALLATION.
Filtres
Filtre à graisses – Un filtre à graisses en aluminium est inclus avec votre hotte et il devrait être nettoyé
dans l’eau chaude avec du détergent une fois par mois. Renverser les instructions dans la section
«terminer l’installation» des instructions pour retirer le filtre. Si le filtre à graisses devient endommagé, le
remplacer par un Filtre à graisses modèle GF-06S de Air King.
Filtre anti-odeurs au charbon – si vous avez installé un filtre combiné à graisse/ charbon, ils ne peuvent pas
être lavés et doivent être jetés lorsqu’ils deviennent notablement sales, qu’ils aient cessé de filtrer les odeurs, ou
au moins une fois par année. Remplacer avec un Filtre Combiné à Graisse / Odeur Modèle CF-06S de Air King.
Nettoyage
ATTENTION : N’UTILISEZ PAS D’ESSENCE, DE BENZINE, DE DILUANT, DE
PRODUITS D’ENTRETIEN PUISSANTS, ETC., PUISQU’ILS POURRAIENT ENDOMMAGER LA HOTTE.
1. Nettoyez la hotte avec du savon doux, comme du savon à vaisselle liquide, et un chiffon doux et
sec. N'UTILISEZ JAMAIS DE TAMPON ABRASIF OU DE POUDRE À RÉCURER. Essuyez complètement
l’appareil avant de rétablir l’alimentation électrique. N’IMMERGEZ JAMAIS DE COMPOSANTS
ÉLECTRIQUES DANS L’EAU.
2. Vous pouvez nettoyer les dépôts (saletés, peluches, etc.) qui se sont accumulés dans le ventilateur à
l’aide d’un aspirateur. Comme le ventilateur est continuellement lubrifié, il n’est pas nécessaire de l’huiler.
Figure 7
Supply from house
Alimentation provenant de
la résidence
Black / Noir
Neutral (White) / Neutre (Blanc)
Ground (Green or Bare)
Mise à la terre (vert ou nu)
Fan / Ventilateur
Black / Noir
Neutral (White) /
Neutre (Blanc)
Green / Vert
Neutral (White) / Neutre (Blanc)
By others / Par d’autres
www.airkinglimited.com
6728002 Rev. P 9-19 4 of 4
LIMITED WARRANTY
WHAT THIS WARRANTY COVERS: This product is warranted against defects in workmanship and/or materials.
HOW LONG THIS WARRANTY LASTS: This warranty extends only to the original purchaser of the product
and lasts for one (1) year from the date of original purchase or until the original purchaser of the product
sells or transfers the product, whichever first occurs.
WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any
part or parts that prove to be defective or replace the whole product with the same or comparable model.
WHAT THIS WARRANTY DOES NOT COVER: This warranty does not apply if the product was damaged or failed
because of accident, improper handling or operation, shipping damage, abuse, misuse, unauthorized repairs
made or attempted. This warranty does not cover shipping costs for the return of products to Air King for repair or
replacement. Air King will pay return shipping charges from Air King following warranty repairs or replacement
ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED
WARRANTY OF MERCHANTABILITY), LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR
UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER
FIRST OCCURS AND IN NO EVENT SHALL AIR KING’S LIABILITY UNDER ANY EXPRESS OR IMPLIED
WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER,
OR (II) REPLACMENT OR REPAIR OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES.
NOTWITHSTANDING ANYTHING TO THE CONTRARY, IN NO EVENT SHALL AIR KING’S LIABILITY UNDER
ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY
SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.
Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion
or limitation of incidental or consequential damages, so these exclusions or limitations may not apply to you.
This warranty gives you specific legal rights. You may also have other rights which vary from state to state
and province to province. Proof of purchase is required before a warranty claim will be accepted.
CUSTOMER SERVICE:
Toll-Free (800) 465-7300
Our Customer Service team is available to assist you with product questions, service center locations, and
replacement parts. They can be reached Monday through Friday, 8am-4pm Eastern. Please have your model
number available, as well as the type and style (located on the label inside of your product).
Please do not return product to place of purchase.
PARTS FOR DISCONTINUED, OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE. DUE
TO SAFETY REASONS, MANY ELECTRONIC COMPONENTS AND MOST HEATER COMPONENTS ARE NOT
AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT.
Troubleshooting Guide
Trouble Probable Cause Suggested Remedy
1. Hood does not operate
when the switch is on.
1a. A fuse may be blown or a
circuit tripped.
1a. Replace fuse or reset circuit breaker.
1b. Wiring is not connected
properly.
1b. Turn off power to unit. Check that all
wires are connected.
2. Hood is operating, but air
moves slower than normal.
2. Obstruction in the exhaust
ducting.
2. Check for any obstructions in the
ducting including filter.
3. Hood is making a rattling
noise.
3a. Filters are loose. 3a. Turn off power to unit. Check that all
filter are securely in place.
3b. Duct connection is loose. 3b. Turn off power to unit. Check that duct
connection is tight.
# Qty.
Qte.
Description Replacement Part #
# de pièce de remplacement
1 1 Filter / Filtre RF35 5S4199011
- Filter / Filtre RF55 5S1199081
2 1 Motor Assembly / Assemblement de Moteur 5S1107103
3 1 Light Lens / Lentille de lumière 5S4199004
4 1 Wire Compartment Cover
Couvercle de compartiment à câblage
5S4199005
5 1 Lamp Holder / Support à lampe 5S4199006
6 1 Switch Plate - White / Plaque d’interrupteur - Blanc 5S1107183
Biscuit 5S1107184
Almond / Amande 5S1107185
Black / Noir 5S1107188
7 1 Louver Plate - White / Plaque de persienne - Blanc 5S1429003
Biscuit 5S1429004
Almond / Amande 5S1429005
Black / Noir 5S1429006
8 1 Damper Assembly (3-1/4" x 10)
Assemblement de adaptateur (3-1/4 x 10 po)
5S1199080
9* 1 Damper Assembly (7" round)
Assemblement de adaptateur (7 po)
5S1429003
Installer / Installateur: Installation Date / Date d’installation:
Place of Purchase / Endroit de l’achat: Model Number / Numéro de modèle:
* Included with AVR series ONLY
Inclus avec la série AVR SEULEMENT
GARANTIE LIMITÉE
CE QUE COUVRE CETTE GARANTIE : Ce produit est garanti contre tout vice de fabrication ou de matière.
COMBIEN DE TEMPS CETTE GARANTIE DURE : Cette garantie se rapporte seulement à l’acheteur original du
produit et dure pendant une (1) année de la date de l’achat original ou jusqu’à ce que l’acheteur original du produit
vend ou transfère le produit, celui qui se produit en premier.
QUE FERA AIR KING : Au cours de la période de garantie, Air King, à son choix, réparera ou remplacera n’importe
quelle partie ou pièces qui s’avèrent défectueuses ou remplacera le produit entier par le même modèle ou un
modèle comparable.
CE QUE CETTE GARANTIE NE COUVRE PAS : Cette garantie ne s’applique pas si le produit était endomma
ou arrête de fonctionner en raison d’un accident, d’une mauvaise manipulation ou opération, de dommages
d’expédition, d’abus, de mauvaise utilisation, de réparation faite ou tentées non autorisées. Cette garantie ne couvre
pas les coûts d’expédition pour le retour des produits à Air King pour la réparation ou le remplacement. Air King
payera les frais d’expédition de retour de Air King après les réparations ou le remplacement de garantie.
TOUTES LES GARANTIES, EXPRESSES OU TACITES (COMPRENANT, SANS LIMITATION, TOUTE GARANTIE
TACITE DE VALEUR MARCHANDE), DURENT UN AN DE LA DATE DE L’ACHAT ORIGINAL OU JUSQU’À CE QUE
L’ACHETEUR ORIGINAL DU PRODUIT VEND OU TRANSFÈRE LE PRODUIT, CELUI QUI SE PRODUIT EN PREMIER
ET DANS AUCUN CAS AIR KING N’ASSUME AUCUNE RESPONSABILITÉ EXPRESSE OU TACITE POUR (I) DES
DOMMAGES ACCIDENTELS OU INDIRECTS DE N’IMPORTE QUELLE CAUSE, OU (II) LE REPLACEMENT OU LA
RÉPARATION DE TOUS FUSIBLES, DISJONCTEURS OU RÉCEPTACLES DE MAISON. MALGRÉ N’IMPORTE QUOI À
L’EFFET CONTRAIRE, DANS AUCUN CAS LA RESPONSABILITÉ D’AIR KING, SOUS UNE GARANTIE EXPRESSE OU
TACITE, NE DÉPASSERA LE PRIX D’ACHAT DU PRODUIT ET UNE TELLE RESPONSABILITÉ SE TERMINERA AVEC
L’EXPIRATION DE LA PÉRIODE DE GARANTIE.
Certains états et provinces ne permettent pas les limitations de la période de garantie, ou l’exclusion ou la restriction
des dommages accidentels ou indirects, et, par conséquent, les présentes restrictions ne peuvent pas s’appliquer.
La présente garantie vous donne des droits légaux spécifiques et peut-être certains autres droits qui peuvent varier
selon la province. La preuve d’achat est exigée avant qu’une réclamation de garantie ne soit acceptée.
SERVICE À LA CLIENTÈLE :
Sans frais (800) 465-7300
Notre équipe de service à la clientèle est disponible pour vous aider avec des questions sur le produit, les
adresses des centres de service, et les pièces de rechange. Vous pouvez la rejoindre, du lundi au vendredi,
de 8h:00 à 16h:00 HNE. Veuillez avoir le numéro du modèle disponible, ainsi que le genre et le style (qui se
trouvent sur l’étiquette à l’intérieur de votre produit).
Veuillez ne pas renvoyer le produit à l’endroit de l’achat.
IL SE PEUT QUE LES PIÈCES POUR LES PRODUITS DISCONTINUÉS, OBSOLÈTES ET AUTRES PRODUITS
NE SOIENT PAS DISPONIBLES. POUR DES RAISONS DE SÛRETÉ, BEAUCOUP DE COMPOSANTS
ÉLECTRONIQUES ET LA PLUPART DES COMPOSANTS DES CHAUFFAGES NE SONT PAS À LA DISPOSITION
DES CONSOMMATEURS POUR L’INSTALLATION OU LE REMPLACEMENT.
Guide de dépannage
Trouble Probable Cause Suggested Remedy
1. La hotte ne fonctionne
pas lorsque l’interrupteur
est à EN (ON).
1a. Un fusible peut être grillé ou un
disjoncteur peut être déclenché.
1a. Remplacer le fusible ou réinitialiser le
disjoncteur.
1b. Le câblage n’est pas raccordé
correctement.
1b. Couper l’alimentation de l’unité. Vérifier
que tous les fils sont raccordés.
2. La hotte fonctionne,
mais l’air circule plus
lentement que la normale.
2. Obstruction dans les conduits
d’évacuation.
2. Vérifier pour quelque obstruction dans
les conduits incluant le filtre.
3. La hotte produit un son
de crécelle.
3a. Le moteur est lâche. 3a. Couper l’alimentation de l’unité.
Retirer le filtre, vérifier que toutes les
vis sont serrées complètement.
3b. Le raccord des conduits est
lâche.
3b. Couper l’alimentation de l’unité.
Vérifier que tous les raccords des
conduits sont bien serrés.
2
3
1
4
5
6
7
8
PARTS DIAGRAM / DIAGRAMME DES PIÈCES
9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Air King AV Series Important Instructions & Operating Manual

Catégorie
Hottes
Taper
Important Instructions & Operating Manual

dans d''autres langues