Dell PowerEdge Rack Enclosure 4210 Guide de démarrage rapide

Taper
Guide de démarrage rapide
Dell™ PowerEdge™ 4210
Installation Guide
Guide d'installation
Installationshandbuch
インストー
Guía de instalación
Dell™ PowerEdge™ 4210
Installation Guide
Notes, Notices, and Cautions
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data
and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury,
or death.
____________________
Information in this document is subject to change without notice.
© 2007 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly
forbidden.
Trademarks used in this text: Dell, the DELL logo, and PowerEdge are trademarks of Dell Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
October 2007 P/N FX668 Rev. A00
Contents 3
Contents
Safety Instructions. . . . . . . . . . . . . . . . . . . . . 5
SAFETY: Rack Mounting of Systems
. . . . . . . . . 5
Installation Instructions
. . . . . . . . . . . . . . . . . . 6
Rack Requirements
. . . . . . . . . . . . . . . . . . 6
Rack Installation
. . . . . . . . . . . . . . . . . . . . . . 6
Before You Begin
. . . . . . . . . . . . . . . . . . . 7
Installation Tasks
. . . . . . . . . . . . . . . . . . . 8
Recommended Tools and Supplies
. . . . . . . . . . 8
Removing and Replacing the Rack Doors
. . . . . . 8
Removing the Front Door
. . . . . . . . . . . . . . . 8
Replacing the Front Door
. . . . . . . . . . . . . . 10
Opening and Removing the Back Doors
. . . . . . 10
Replacing the Back Doors
. . . . . . . . . . . . . 13
Removing the Side Panels
. . . . . . . . . . . . . 13
Replacing the Side Panels
. . . . . . . . . . . . . 14
Reversing the Front Door (optional)
. . . . . . . . 14
Securing the Rack Leveling Feet
. . . . . . . . . . 19
Installing the Rack Stabilizer Feet
. . . . . . . . . 21
Routing Cables
. . . . . . . . . . . . . . . . . . . 24
Removing the Door Panels From the
Optional Door Kit
. . . . . . . . . . . . . . . . . . 26
Coupling Two Racks
. . . . . . . . . . . . . . . . . . . 26
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4 Contents
Dell™ PowerEdge™ 4210 Installation Guide 5
Safety Instructions
Use the following safety guidelines to ensure your own personal safety and to
help protect your system and working environment from potential damage.
For complete safety and regulatory information, see the Product Information
Guide that shipped with your system. Warranty information might be
included in this document or as a separate document.
SAFETY: Rack Mounting of Systems
Observe the following precautions for rack stability and safety. Also refer to
the rack installation documentation accompanying the system and the rack
for specific caution statements and procedures.
Systems are considered to be components in a rack. Thus, "component" refers
to any system as well as to various peripherals or supporting hardware.
CAUTION: Before installing systems in a rack, install front and side stabilizers on
stand-alone racks or the front stabilizer on racks joined to other racks. Failure to
install stabilizers accordingly before installing systems in a rack could cause the
rack to tip over, potentially resulting in bodily injury under certain circumstances.
Therefore, always install the stabilizer(s) before installing components in the rack.
After installing system/components in a rack, never pull more than one component
out of the rack on its slide assemblies at one time. The weight of more than one
extended component could cause the rack to tip over and may result in serious
injury.
NOTE: Your system is safety-certified as a free-standing unit and as a component
for use in a Dell rack cabinet using the customer rack kit. The installation of your
system and rack kit in any other rack cabinet has not been approved by any safety
agencies. It is your responsibility to ensure that the final combination of system and
rack complies with all applicable safety standards and local electric code
requirements. Dell disclaims all liability and warranties in connection with such
combinations.
System rack kits are intended to be installed in a rack by trained service
technicians. If you install the kit in any other rack, be sure that the rack
meets the specifications of a Dell rack.
6 Dell™ PowerEdge™ 4210 Installation Guide
CAUTION: Do not move racks by yourself. Due to the height and weight of the
rack, a minimum of two people should accomplish this task.
Before working on the rack, make sure that the stabilizers are secured to
the rack, extended to the floor, and that the full weight of the rack rests on
the floor. Install front and side stabilizers on a single rack or front
stabilizers for joined multiple racks before working on the rack.
Always load the rack from the bottom up, and load the heaviest item in the
rack first.
Make sure that the rack is level and stable before extending a component
from the rack.
Use caution when pressing the component rail release latches and sliding a
component into or out of a rack; the slide rails can pinch your fingers.
Ensure that proper airflow is provided to components in the rack.
Do not step on or stand on any component when servicing other
components in a rack.
Installation Instructions
This installation guide provides instructions for trained service technicians
installing a 42-unit (U) rack. Information includes assembling the rack,
coupling two 42-U racks, and routing cables through the rack. The 42-U rack
can be installed using the recommended tools.
Rack Requirements
NOTICE: The 42-U rack meets the specifications of American National
Standards Institute (ANSI)/Electronic Industries Association (EIA) standard
ANSI/EIA-310-D-92, Consumer Electronics Association (CEA) Standard CEA-310-E,
International Electrotechnical Commission (IEC) 297, and Deutsche Industrie Norm
(DIN) 41494.
Rack Installation
Before attempting this installation, you should read through this entire
procedure carefully.
Dell™ PowerEdge™ 4210 Installation Guide 7
Before You Begin
CAUTION: Before you begin installing your rack, carefully read "Important Safety
Information," as well as the safety instructions found in your system’s System
Information Guide for additional information.
CAUTION: When installing multiple systems in a rack, complete all of the
procedures for the current system before attempting to install the next system.
CAUTION: Rack cabinets can be extremely heavy and move easily on the casters.
The cabinet has no brakes. Use extreme caution while moving the rack cabinet.
Retract the leveling feet when relocating the rack cabinet. Avoid long or steep
inclines or ramps where loss of cabinet control may occur. Extend the leveling
feet for support and to prevent the cabinet from rolling.
CAUTION: Do not attempt to move your rack with components installed. If you
move a fully loaded rack on a slightly uneven floor surface, the rack may become
unstable and tip over.
Important Safety Information
Observe the safety precautions in the following subsections when installing
your system in the rack.
CAUTION: You must strictly follow the procedures in this document to protect
yourself as well as others who may be involved. Your system may be very large
and heavy, and proper preparation and planning are important to prevent injury to
yourself and to others. This becomes increasingly important when systems are
installed high up in the rack.
Rack Stabilizer Feet
CAUTION: Installing systems in a rack without the front and side stabilizer feet
installed could cause the rack to tip over, potentially resulting in bodily injury
under certain circumstances. Therefore, always install the stabilizer feet before
installing components in the rack.
CAUTION: After installing systems in a rack, never pull more than one system out
of the rack on its slide assemblies at one time. The weight of more than one
extended system could cause the rack to tip over and cause injury.
The stabilizer feet help prevent the rack from tipping over when a system or
other component is pulled out of the rack with the slide assemblies fully
extended.
8 Dell™ PowerEdge™ 4210 Installation Guide
Installation Tasks
Installing a rack cabinet involves performing the following tasks:
1
Removing and replacing the rack doors
2
Removing and replacing the side panels
3
Reversing the front door and badge (optional)
4
Securing the leveling feet
5
Installing the stabilizer feet
6
Routing cables through the rack
7
Coupling two racks (optional)
8
Removing high-density rear door panels
Recommended Tools and Supplies
You may need the following tools and supplies to install the rack:
#2 Phillips screwdriver
Flat head screwdriver
12-mm wrench
Needle-nose pliers
4-mm Allen wrench (if you want to reverse the direction that the front
door opens)
5-mm Allen wrench (included in kit)
Keys to the rack doors and side panels
Removing and Replacing the Rack Doors
CAUTION: Because of the size and weight of the rack cabinet doors, never
attempt to remove or install them by yourself.
CAUTION: Store the doors where they will not injure someone if the doors
accidently fall over.
Removing the Front Door
1
Press the door-latch button to release the door handle, then open the front
door all the way (see Figure 1-1).
Dell™ PowerEdge™ 4210 Installation Guide 9
2
While holding the door, pull the top hinge pin upward so that it clears the
door’s hinge-pin housing (see Figure 1-1).
The hinge pin’s retention clip prevents the hinge from being pulled out of
the hinge body.
Figure 1-1. Removing the Front Door
3
While holding the hinge pin out of the door’s hinge-pin housing, pull the
door slightly away from the rack so that the door clears the hinge body.
4
Release the hinge pin.
1 door-latch button 2 hinge pin
3 hinge body 4 hinge-pin housing
4
2
3
1
10 Dell™ PowerEdge™ 4210 Installation Guide
5
Lift the door upward so that the door clears the bottom hinge post.
CAUTION: Due to the size and weight of the door, it is recommended that you lay
the removed door flat.
6
Lay the panel in a safe location with the panel’s outer surface facing
upward.
Laying the door flat with the outer surface facing upward will help prevent
damage to the door’s cosmetic coating.
Replacing the Front Door
To replace the front door, perform the steps for removal in reverse.
Opening and Removing the Back Doors
CAUTION: Because of the size and weight of the rack cabinet doors, never
attempt to remove or install them by yourself.
1
Open the back doors.
a
Press the door-latch button to release the right door handle (see
Figure 1-2).
b
Open the right door.
c
Compress the left door’s pinch latch to release the left door (see
Figure 1-2).
d
Open the left door.
Dell™ PowerEdge™ 4210 Installation Guide 11
Figure 1-2. Opening the Left Back Door
2
Remove the right door.
a
While supporting the door, pull the pin for the top hinge out of the
door’s hinge-pin housing (see Figure 1-3).
You will hear a click as you pull the pin out of the door’s hinge-pin
housing. The hinge pins are designed to prevent them from being
pulled out of the hinge body.
b
Repeat step a for the bottom hinge.
c
Pull the door away from the rack.
1 pinch latch 2 door-latch button
1
2
12 Dell™ PowerEdge™ 4210 Installation Guide
Figure 1-3. Removing the Back Doors
CAUTION: Due to the size and weight of the door, it is recommended that you lay
the removed door flat with its outer surface facing upward.
d
Lay the door in a safe location with the door’s outer surface facing
upward.
Laying the door flat with the outer surface facing upward helps
prevent damage to its cosmetic coating.
e
Repeat steps a through d for the left door.
1 hinge pin 2 hinge body
3 hinge-pin housing
1
2
3
Dell™ PowerEdge™ 4210 Installation Guide 13
Replacing the Back Doors
To replace the back doors, perform the steps for removal in reverse.
Removing the Side Panels
CAUTION: Because of the size and weight of the rack cabinet side panels, never
attempt to remove or install them by yourself.
NOTE: You must remove the side panels in order to install the side stabilizer feet.
Also, although removing the side panels is not mandatory for installing systems in a
rack, having the sides open makes it easier to install slide assemblies and support
rails and to reverse the direction that the front door opens.
1
Unlock the locks near the left and right edges of the panel (see Figure 1-4).
Figure 1-4. Removing a Side Panel
1 side panel (2) 2 locks (2)
3 handles (2)
1
2
3
14 Dell™ PowerEdge™ 4210 Installation Guide
2
Allow the side panel to swing outward slightly from the bottom.
3
Grasp the panel firmly using the handles.
4
Lift the panel upward until it clears the top of the rack (see Figure 1-4).
5
Pull the side panel away from the rack.
CAUTION: Because of the size and weight of the rack cabinet side panels, never
attempt to remove or install them by yourself.
6
Place the panel in a safe location with the panel’s outer surface facing
upward.
Placing the panel with the outer surface facing upward helps prevent
damage to its cosmetic coating.
7
Repeat step 1 through step 6 for the other side panel.
Replacing the Side Panels
CAUTION: Because of the size and weight of the rack cabinet side panels, never
attempt to remove or install them by yourself.
To replace the side panels, perform the removal steps in reverse.
Reversing the Front Door (optional)
NOTE: Use a 4-mm Allen wrench to remove the front-door hinge bodies from the
rack and reinstall them on the side opposite their original positions. You might need
a stepladder in order to access the Allen bolt that secures the top hinge body to the
rack.
To reverse the direction that the front door opens, complete the following
steps:
1
Remove the front door. For instructions, see "Removing the Front Door."
2
Remove the side panels. For instructions, see "Removing the Side Panels."
3
Reverse the top hinge body.
a
Pull the hinge pin upward slightly so that you can access the retention
clip (see Figure 1-5).
b
Using the needle-nose pliers, remove the retention clip, and slide the
hinge pin out of the hinge body.
Dell™ PowerEdge™ 4210 Installation Guide 15
Figure 1-5. Removing the Front-Door Hinges
c
Remove the hinge spring from the hinge body.
d
Place the hinge pin, retention clip, and spring in a safe location.
e
Using the 4-mm Allen wrench, remove the Allen bolt that secures the
hinge body to the rack, and place the bolt with the hinge pin,
retention clip, and spring.
1 hinge post 2 retention clip
3 spring 4 hinge pin
5 top hinge body 6 bottom hinge body
4
3
2
5
6
1
16 Dell™ PowerEdge™ 4210 Installation Guide
f
Rotate the hinge body 180 degrees so that the hinge-pin holes are now
on the right side of the hinge body (see Figure 1-6).
Figure 1-6. Reversing the Top and Bottom Hinges
1 hinge pin 2 top hinge body
3 spring 4 retention clip
5 hinge post 6 bottom hinge body
7 front of rack
2
3
4
1
5
6
7
Dell™ PowerEdge™ 4210 Installation Guide 17
g
Locate the top bolt hole in the right side of the rack, and fasten the
hinge body to the right side of the rack with the Allen bolt.
h
Insert the spring between the top and bottom hinge-pin holes in the
hinge body.
i
Slide the hinge pin into the hinge body.
j
Insert the retention clip through the hinge so that the retention clip is
below the spring.
4
Reverse the bottom hinge body.
a
Remove the Allen bolt that secures the hinge body to the rack, and
place the bolt in a safe location.
b
Rotate the hinge body 180 degrees so that the hinge posts are now on
the right side of the hinge body (see Figure 1-6).
c
Locate the bottom bolt hole in the right side of the rack, and use the
Allen bolt to fasten the hinge body to the right side of the rack.
5
Rotate the front door 180 degrees so that its hinge-pin housings are on the
right side (see Figure 1-7).
18 Dell™ PowerEdge™ 4210 Installation Guide
Figure 1-7. Rotate Front Door
6
Rehang the front door by reversing the steps in "Removing the Front
Door."
7
Reverse the lock catch.
a
Use the #2 Phillips screwdriver to remove the two #2 Phillips screws
that hold the lock catch to the middle horizontal frame member.
b
Remove the lock catch and rotate it 180 degrees.
c
Reinstall the lock catch on the new horizontal frame member by
aligning the holes of the catch with the holes of the frame member
and then reinserting the two #2 Phillips screws.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162

Dell PowerEdge Rack Enclosure 4210 Guide de démarrage rapide

Taper
Guide de démarrage rapide