CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
3) Make wire connections. Reference chart below for correct con-
nections and wire accordingly.
4) Carefullypushxture[4] to wall making sure all connections
remain secure and wires do not get pinched.
5) Insert and tighten mounting screws[5]tosecureFixture[4] to
wall.
INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS
AND/OR IN WET LOCATIONS.
6) Mountingsurfaceshouldbeclean,dry,atand1/4”larger
that the canopy on all sides. Any gaps between the mounting
surfaceandcanopyexceeding3/16”shouldbecorrectedas
required.
7) With silicone caulking compound, caulk completely around
where back of canopy meets the wall surface to prevent water
fromseepingintooutletbox.
WARNING:
Thisxtureisintendedforinstallationinaccordancewiththe
NationalElectricalCode(NEC)andalllocalcodespecications.
If you are not familiar with code requirements, installation by a
certiedelectricianisrecommended.
CLEANING:
Always be certain that electric current is turned off before cleaning.
Only a damp cloth should be used. Harsh cleaning products may
damagethenish.
FCC INFORMATION:
Thisdevicecomplieswithpart15oftheFCCRules.Operationis
subject to the following two conditions:
(1) Thisdevicemaynotcauseharmfulinterference,and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the
limitsforaClassBdigitaldevice,pursuanttopart15oftheFCC
Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference
to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following mea-
sures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
INSTALLATION:
Read and understand all instructions and illustrations completely
beforeproceedingwithassemblyandinstallationofxture.
• Ifyouhaveanydoubtsabouthowtoinstallthisxture,orifthe
xturefailstooperatecompletely,pleasecontactaqualied
electrician.
All parts must be used as indicated in the instructions. Do not
substitute any parts, leave parts out, or use any parts that are
worn or broken. Failure to obey this instruction could invalidate
theULlisting,C.S.A.certication,and/orETLlistingofthis
xture.
• Fixtureistobeconnectedtoasinglebranchcircuit.
• Mountingsurfaceshouldbeclean,dry,atand1/4”largerthan
thexturehousingsurface.
Instructions
1) Attachthemountingplate[1]totheoutletbox[2] with supplied
screws[3]. NOTE: The mounting plate[1] must be mounted
withthexturethreadedmountingholesmatchingmounting
holesonxture[4].
2) Grounding instructions: (See Illus. A or B).
A) Onxtureswheremountingstrapisprovidedwithahole
andtworaiseddimples.Wrapgroundwirefromoutletbox
around green ground screw, and thread into hole.
B) Onxtureswhereacuppedwasherisprovided.Attach
groundwirefromoutletboxundercuppedwasherand
green ground screw, and thread into mounting strap.
Ifxtureisprovidedwithgroundwire.Connectxtureground
wiretooutletboxgroundwirewithwireconnector.(Notpro-
vided.) After following the above steps. Never connect ground
wire to black or white power supply wires.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
Date Issued: 09/27/17
IS-49973LED-CB
INSTRUCTIONS
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
Nous sommes là pour vous aider 866-558-5706
Heures : du lundi au vendredi, de 9h à 17h (heure de l’Est)
ATTENTION – RISQUE DE DÉCHARGES ÉLECTRIQUES -
Couper le courant au niveau du panneau du disjoncteur du
circuit principal ou de la boîte à fusibles principale avant de
procéder à l’installation.
AVERTISSEMENT :
Ce luminaire doit être installé conformément aux codes d’électricité
nationaux (NEC) et satisfaire toutes les spécications des codes
locaux. Si vous ne connaissez pas les exigences de ces codes, il
est recommandé de coner l’installation à un électricien certié.
NETTOYAGE :
Toujours veiller à ce que le courant électrique soit coupé avant de
nettoyer. Utiliser uniquement un chiffon doux humidié. Les produits
de nettoyage trop puissants peuvent endommag er la nition.
FCC INFORMATION :
Cet appareil est conforme à la section 15 de la réglementation de la
FCC. L’exploitation est soumise aux deux conditions suivantes :
(1) Cet équipement ne doit pas causer d’interférences
nuisibles, et
(2) cet équipement doit accepter toute interférence reçue, y
compris les interférences risquant d’engendrer un fonc-
tionnement indésirable.
Remarque: Des tests ont conrmé que ce matériel respecte les
limites d’un dispositif numérique de catégorie B, en vertu de la sec-
tion 15 de la réglementation de la FCC. Ces limites ont été conçues
pour fournir une protection raisonnable contre le brouillage nuisible
d’une installation résidentielle. Cet équipement génère, utilise et
peut rayonner de l’énergie radiofréquence et, s’il n’est pas installé
et utilisé selon les instructions, peut causer de l’interférence nuis-
ible aux communications de radio. Cependant, il est néanmoins
possible qu’il y ait de l’interférence dans une installation en particu-
lier. Si cet équipement cause du brouillage nuisible à la réception
du signal de radio ou de télévision, ce qui peut être déterminé en
éteignant puis en rallumant l’appareil, l’usager peut essayer de cor-
riger l’interférence en appliquant une des mesures suivantes :
Réorienter l’antenne de réception ou changer son emplace-
ment.
Augmenter la distance séparant l’équipement et le récepteur.
Brancher le matériel dans la prise de courant d’un circuit dif-
férent de celui auquel le récepteur est branché.
Consulter le revendeur ou un technicien radio/télé
d’expérience.
INSTRUCTIONS :
1) Fixez la plaque de montage [1] à la boîte de sortie [2] avec les
vis fournies [3]. REMARQUE: La plaque de montage [1] doit
être montée avec les trous de montage letés xés correspon-
dant aux trous de montage sur le luminaire [4].
2) Connecter les ls. Se porter au tableau ci-dessous pour faire les
connexions.
3) Replacer soigneusement les connexions de l dans la boîte de
sortie en s’assurant que toutes les connexions restent sécuri-
sées[4].
4) Serrez les vis de xation pour xer[5] le luminaire[4] sur le
mur.
INSTRUCTIONS DE MONTAGE DE LUMINAIRE À L’EXTÉRIEUR
ET/OU DANS DES LIEUX HUMIDES.
5) La surface de montage doit être propre, sèche, plate et de 0,6
cm plus épaisse que le cache sur tous les côtés. Tout écart
entre la surface de montage et le cache dépassant de 0,5 cm
doit être rectié selon les besoins.
6) À l’aide de matériaux d’étanchéité à la silicone, calfeutrer bien
autour où l’arrière du cache entre en contact avec le mur pour
empêcher l’eau de passer dans la boîte de raccordement.
Connecter le fil noir ou
rouge de la boite
Connecter le fil blanc de la boîte
A Noir A Blanc
*Au cordon parallèle (rond et lisse)
*Au cordon parallele (à angles droits el strié)
Au bransparent, doré, marron, ou
noir sans fil distinctif
Au transparent, doré, marron, ou
noir avec un til distinctif
Fil isolé (sauf fil vert) avec
conducteur en cuivre
Fil isolé (sauf fil vert) avec
conducteur en argent
*Remarque: Avec emploi d’un fil paralléle
(SPT I et SPT II). Le fil neutre est á angles
droits ou strié et l’autre fil doit étre rond ou
lisse (Voir le schéma).
Fil Neutre
  • Page 1 1