Zephyr ZRP-E48AS Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur

Ce manuel convient également à

Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
AUG19.0101 © Zephyr Ventilation LLC.
Roma Pro Wall
ZRP-E36AS
ZRP-E48AS
READ AND SAVE THESE INSTRUCTIONS
www.zephyronline.com
1
SAFETY NOTICE ................................................................. 2-3
LIST OF MATERIALS ....................................................... 4
INSTALLATION
Ducting Calculation Sheet
....................................... 5
Mounting Height & Clearance
................................ 6
Ducting Options
........................................................... 7
Specications
............................................................... 8
Mounting the Range Hood
...................................... 9
PBD-1300A Dual Blower Ducting
......................... 10
FEATURES & CONTROLS
Electronic LCD Controls
........................................... 11
Optional Remote Control
......................................... 12
MAINTENANCE
Cleaning, Filter Removal & Lights
....................... 13
TROUBLESHOOTING
................................................................ 14
ACT™ CONVERSION
................................................................ 15
WIRING DIAGRAMS
................................................................... 16
LIST OF PARTS AND ACCESSORIES
.............................. 17
WARRANTY
.................................................................................... 18
PRODUCT REGISTRATION
.................................................... 19
Table of Contents
Important Safety Notice
READ AND SAVE THESE INSTRUCTIONS
2
www.zephyronline.com
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
b. Beforeservicingorcleaningunit,switchpoweroatservicepanelandlockpaneltopreventpowerfrombeingswitchedonaccidentally.
Whentheservicedisconnectingmeanscannotbelocked,securelyfastenaprominentwarningdevice,suchasatag,totheservice
panel.
CAUTION
Forgeneralventilatinguseonly.Donotusetoexhausthazardousorexplosivematerialsandvapors.Takecarewhenusingcleaning
agentsordetergents.Suitableforuseinhouseholdcookingarea.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a. Neverleavesurfaceunitsunattendedathighsettings.Boiloverscausesmokingandgreasyspilloversthatmayignite.Heatoilsslowly
on low or medium settings.
b. AlwaysturnhoodONwhencookingathighheatorwhenamingfood
c. Cleanventilatingfansfrequently.Greaseshouldnotbeallowedtoaccumulateonfanorlter.
d. Useproperpansize.Alwaysusecookwareappropriateforthesizeofthesurfaceelement.
e. Keepfan,ltersandgreaseladensurfacesclean.
f. Use high setting on hood only when necessary.
g. Don’tleavehoodunattendedwhencooking.
h. Alwaysusecookwareandutensilsappropriateforthetypeofandamountoffoodbeingprepared.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:
a. SMOTHERFLAMESwithaclose-ttinglid,cookiesheet,ormetaltray,thenturnotheburner.BECAREFULTOPREVENTBURNS.
Iftheamesdonotgooutimmediately,EVACUATEANDCALLTHEFIREDEPARTMENT.
b. NEVER PICK UP A FLAMING PAN – You may be burned.
c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d. Use an extinguisher ONLY if:
1. YouknowyouhaveaClassABCextinguisher,andyoualreadyknowhowtooperateit.
2. Thereissmallandcontainedintheareawhereitstarted.
3. Theredepartmentisbeingcalled.
4. Youcanghttherewithyourbacktoanexit
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Installationworkandelectricalwiringmustbedonebyqualiedperson(s)inaccordancewithallapplicablecodesandstandards.
Includingre-ratedconstruction.
b. Sucientairisneededforpowercombustionandexhaustingofgasesthroughtheue(chimney)offuelburningequipmenttoprevent
back-drafting.Followtheheatingequipmentmanufacturer’sguidelineandsafetystandardssuchasthosepublishedbytheNational
FireProtectionAssociation(NFPA)andtheAmericanSocietyforHeating,RefrigerationandAirConditioningEngineers(ASHRAE)and
the local code authorities.
c. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d. Ducted fans must always vent to the outdoors.
e. NEVER place a switch where it can be reached from a tub or shower.
f. Makesurethepowerisobeforeinstalling,wiringormaintenancing.
Important Safety Notice
3
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
Toreduceriskofreandtoproperlyexhaustairoutside-Donotventexhaustairintospaceswithinwalls,ceilings,
attics, crawl spaces or garages.
OPERATION
Alwaysleavesafetygrillesandltersinplace.Withoutthesecomponents,operatingblowerscouldcatchontohair,ngers
and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to
negligence and the warranty of the unit automatically expires due to improper maintenance.
*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
ELECTRICAL REQUIREMENTS
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility:
- Tocontactaqualiedelectricalinstaller.
- To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70
latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and
all local codes and ordinances.
Ifcodespermitandaseparategroundwireisused,itisrecommendedthataqualiedelectriciandeterminethatthe
ground path is adequate.
Do not ground to a gas pipe.
Checkwithaqualiedelectricianifyouarenotsuretherangehoodisproperlygrounded.
Do not have a fuse in the neutral or ground circuit.
*NationalFireProtectionAssociationBatterymarchPark,Quincy,Massachusetts02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit
protectedbya15or20amperecircuitbreakerortimedelayfuse.Wiringmustbe2wirewithground.Pleasealsoreferto
Electrical Diagram on product.
Acablelockingconnector(notsupplied)mightalsoberequiredbylocalcodes.Checkwithlocalrequirements,purchase
and install appropriate connector if necessary.
FEDERAL COMMUNICATION COMMISSION INTERFACE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
televisionreception,whichcanbedeterminedbyturningtheequipmentoandon,theuserisencouragedtotrytocorrect
the interference by one of the following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
.Connecttheequipmentintoanoutletonacircuitdierentfromthattowhichthereceiverisconnected.
. Consult the dealer or an experienced radio/TV technician for help
Cancer and Reproductive Harm - www.P65Warnings.ca.gov
WARNING:
Prop. 65 Warning for California Residents
4
www.zephyronline.com
MODELS: ZRP-E36AS, ZRP-E48AS
PARTS SUPPLIED
1 - Hood
2 - Duct covers, 1 upper & 1 lower
1-Ductcoverbracket
2-Baelters,ZRP-E36AS
3-Baelters,ZRP-E48AS
2 - LED light bulbs, ZRP-E36AS
4 - LED light bulbs, ZRP-E48AS
1-8in.roundstartingcollar(for single blower ducting)
1-Hardwarepackage
PARTS NOT SUPPLIED
- Ducting, conduit and all installation tools
-Cableconnector(ifrequiredbylocalcodes)
-DualInternalBlowerKit(PBD-1300A)
- Duct Cover Extension Accessory
- Remote Control Accessory
List of Materials
5
Installation – Ducting Calculation Sheet
Duct pieces
To tal
Equivalent number
length x used =
3- 1/ 4” x 10”
Rect.,
straight
1 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
5 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
90
0
elbow
20 Ft. x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
90
0
15 Ft.
x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
45
0
9 Ft. x ( ) =
Ft.
Ft.
6”, 7”, 8”, 10”
Round,
straight
1 Ft. x ( ) =
Ft.
Subtotal column 1 =
Duct pieces
To tal
Equivalent number
length x used =
6”, 7”, 8”, 10”
Round, wall
cap with
damper
30 Ft. x ( ) =
Ft.
Ft.
Ft.
Ft.
6”, 7”, 8”, 10”
Round
roof cap
30 Ft. x ( ) =
Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Maximum Duct Length: For satisfactory air movement,
the total duct length
should not exceed 100 equivalent feet.
6” round to
3- 1/ 4” x 10”
rect.
transition
1 Ft. x ( ) =
Ft.
6” round to
3- 1/ 4” x 10”
rect.
transition
90
0
elbow
16 Ft. x ( ) =
Ft.
7” round to
3 1/ 4” x 10”
rect.
transition
8 Ft. x ( ) =
Ft.
7” round to
3- 1/ 4” x 10”
rect.
transition
90
0
elbow
23 Ft. x ( ) =
Ft.
elbow
elbow
7” to 6” or
8” to 7” Round
tapered
reducer
25 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 90
0
elbow
15 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 45
0
elbow
9 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 90
0
flat elbow
24 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) =
Ft.
Ft. x ( ) =
Ft.
15
6”, 7“, 8”
Round
in-line
damper
Installation – Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum of 8” round duct must be used to
maintainmaximumairoweciencyforsingle
internal blower and 10” round duct for dual internal
blower.
Always use rigid type metal ducts only. Flexible
ductscouldrestrictairowbyupto50%.
Alsousecalculation(onpage5)tocomputetotal
available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size.
If turns or transitions are required; install as far
away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood
bottom should be no less than 24”.
Maximum mount height should be no higher than
36”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
resultinheatdamageandrehazard;whilehoods
mounted too high will be hard to reach and will
loseitsperformanceandeciency.
If available, also refer range manufacturer’s height
clearance requirements and recommended hood
mounting height above range.
Vertical Ducting:
8”roundminimum(singleinternalblower)
10”roundminimum(dualinternalblower)
DAMAGE-
SHIPMENT / INSTALLATION:
Please fully inspect unit for damage before
installation.
If the unit is damaged in shipment, return the
unit to the store in which it was bought for
repair or replacement.
If the unit is damaged by the customer, repair
or replacement is the responsibility of the
customer.
• Iftheunitisdamagedbytheinstaller(ifother
thanthecustomer),repairofreplacementmust
be made by arrangement between customer
and installer.
24” min.
36” max.
min. A
max. B
min. C
max. D
Standard Extension
Hood Heights Duct Cover Duct Cover
minimum ducted (A) 31 1/2” 43“
maximum (B) 51” 79”
Ceiling Heights
minimum ducted (C) 91 1/2”
(7’ 7 1/2”) 103“ (8‘ 7”)
maximum (D) 121” (10’ 1“ ) 149” (12’ 5”)
36”
7
WARNING FIRE HAZARD
NEVERexhaustairorterminateductworkintospacesbetweenwalls,crawlspaces,ceiling,atticsorgarages.
All exhaust must be ducted to the outside.
Userigidmetalductworkonly.
FastenallconnectionswithsheetmetalscrewsandtapealljointswithcertiedAluminumTapeorDuctTape.
Some Ducting Options
Installation – Ducting Options
side wall cap
w/ gravity damper
Soffit or crawl space
Roof Pitch w/
Flashing & Cap
8
www.zephyronline.com
Installation – Specications
Standard
Min. - 31 1/2”
Max. - 51”
Z1C-00RP
Min. - 43”
Max. - 79”
14 1/2”
(36”) 35 7/8”, (48”) 47 7/8”
6 5/16”
21 1/4”
15”
24”
6 5/8”
7 7/8” or
9 15/16”
18 1/2”
19 7/8”
1 7/16”
26 3/4”
11 13/16” (36”)
13 3/4” (48”)
11 13/16” (36”)
13 3/4” (48”)
9
A
C
B
14-1/2
4-7/8”
19-7/8”
C/L
24" min.
2
Duct Cover
Bracket
1
11-13/16” (36”)
13-3/4” (48”)
11-13/16” (36”)
13-3/4” (48”)
Installation – Mounting the Range Hood
1. MeasurefromrangetoptohoodbottomandmarklineA.(24”
minimumfromrangetop).
2. Plumandmarkcenterline.
3. MarkmountingheightlineB.(14-1/2”fromlineA)
4.MarkmountingheightlineC.(4-7/8”fromlineA)
5. MarkmountingspreadfromC/LonlineBandCaccordingto
diagram.
6. Fasten(2)6#x2”screwsintostudsonlineB.Fasten(3)6#x
2” screws into studs on line C. Do not fasten screws all the way,
leave approxamately 3/8” exposed. Note: wood blocking may
need to be added behind the drywall if no studs are present.
Wall anchors may also be used but check local codes for
compliance. Failure to use suitable wall anchors and screws
to hold the weight of the hood could result in personal injury
or damage to cooking surface or counter.
7.Installroundductcollarwithbackdraftdampertotoporrearof
hoodby(4)M4x8screws.
8. Hanghoodontowallmountedscrewsandtighten.(FIG.A#1)
9.Centerandattachductcoverbrackettowallbelowceilingorsot
using(2)6#x11/2”screws.
10.Prepairandconnectelectricalandinstallductworkandducttape.
11.Poweruphoodandcheckforleaksaroundducttape.
12. Place telescopic duct covers onto hood and extend inner
(top)ductcoverupwardsandsecuretoductcoverbracket
using(2)M4x8screws.
CAUTION: At least two installers are required
due to the weight and size of the hood.
!
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
!
Cable Lock
Warning:
Forpersonalsafety,removehousefuseoropencircuitbreakerbeforebeginninginstallation.Donot
use extension cord or adaptor plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
Electrical Supply:
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly
goundedbrandcircuit,protectedbya15or20amperecircuitbreakerortimedelayfuse.Wiringmust
be 2 wire w/ground. Please refer to Electrical Diagram labeled on product.
Cable Lock:
Acablelockingconnector(notsupplied)mightalsoberequiredbylocalcodes.Checkwithlocal
requirements and codes, purchase and install appropriate connector if necessary.
10
www.zephyronline.com
Installation – PBD-1300A Dual Blower Ducting
1. Disconnectblowerplugandwhiteandblack
power cables.
2. Remove(4)screwsfrominteriorofhoodbody
attaching single blower plate to top of hood
body. Remove single blower and single blower
plate.
3. Remove(4)screwsattachingsingleblowerto
single blower plate.
4. Attachsingleblowertodualblowerplateby(4)
previously removed screws from step 3.
This range hood is equipped standard with a single blower vertical duct option. To convert from single blower
vertical ducting to dual blower vertical ducting please following the instructions below.
5. Position dual blower inside hood body as
shown.Besuretotuckdualblowerplateinto
blowerplatetabs.Securedualblowerby(4)
screws previously removed from step 2.
6. Attach 10” round blower collar to top of hood
bodyby(4)M4x8screws.Connectblower
wire extension cable to new blower and connect
plugs from each blower to female plugs behind
switch panel.
11
1. Power / Delay Off
Power Button Function
On/Off button will turn power on and off for entire hood (fan and lights). The hood will remember the last speed and light level it
was turned off at.
Delay Off Button Function
With the fan on, press and hold the On/Off button for three seconds. The fan will change to speed 1 and the 10 minute delay off
timer will start. A countdown timer will show on the display indicating the time left until the fan and lights automatically turn off.
Pressing the On/Off button while the Delay Off Function is enabled will turn the hood off and cancel the Delay Off Function.
ACT Verification
Airflow Control Technology (ACT™) allows the installer to set the maximum blower CFM to align with local codes and regulations.
To verify the maximum blower CFM:
With hood off, hold the On/Off button for three seconds. The Display will show if ACT™ is disabled and set to the maximum
CFM or if ACT™ is enabled and set to one of the restricted maximum CFM levels of 590, 390 or 290.
2. Speed Selection
The 6 speed levels are selected by pressing Fan - to decrease and Fan + to increase speed levels. The Display indicates the
speed level selected.
ACT Enabled Speed Selections
When ACT™ is enabled, the number of fan speeds will be reduced to Maximum 3 speeds.
3. Lights On/Dim/Off
Switch lights on by pressing Lights button once, press a second time to dim and again to shut off lights.
4. Display
The display window indicates speed levels and features such as baffle filter clean reminder, delay off and clean air indicator.
Filter Clean Reminder
After 30 hours of fan usage the words “Clean grease filters” will show on the Display indicating it is time to clean the filters.
To Reset: With hood off, hold the Fan - button for 3 seconds until the display words “Clean grease filters” turns off
Clean Air
Clean Air is a feature that turns the fan on every 4 hours for 10 minutes to remove stagnant air in the kitchen.
To enable Clean Air Function:
With hood off, hold the Fan - button and Fan + button simultaneously for three seconds. The words “CleanAir Function
Activated” will illuminate and the fan will turn on speed 1 for 10 minutes. After 10 minutes the fan will turn off and the 4 hour
timer will begin.
To disable Clean Air Function:
With hood off, hold the Fan - button and Fan + button simultaneously for three seconds. The words “CleanAIr Function
Deactivated” will illuminate indicating the function has been disabled.
When the Clean Air Function is enabled the fan will turn on speed 1 for 10 minutes every 4 hours of non fan usage. After 10
minutes the fan will turn off and the 4 hour timer will reset.
If the user changes the fan speed while the Clean Air Function is in use, the Clean Air Function will stop. If the user presses the
On/Off button at any time the 4 hour Clean Air timer will reset.
Optional Remote Control Pairing
To create a unique link between your hood and optional remote control please follow these steps.
With Hood off, press and hold the Lights button until the Display shows the words “Remote Pairing...” then press any button on
the remote, the Display will then show the words “Remote Paired” indicating the remote control pairing is complete.
Power / Delay Off
Adjust 6 Speed Levels
Display
Lights On/Dim/Off
Features & Controls – Electronic LCD Controls
12
www.zephyronline.com
RF REMOTE MAINTENANCE:
Clean the remote control using non abrasive detergents
Follow instructions below for replacing battery.
Usingasmallatheadscrewdriver,raisethecoverofthebattery
door(A)inordertoaccessthebatterycompartment.FIG.2.
Remove the battery and replace with battery type A23 12V.
Negative end of battery should face the spring inside the remote.
Re-install battery door and recycle old battery.
RF REMOTE FEATURES:
TheRFremotecontrolisequippedwithamagnetonthebackforeasy
storage. The remote may be placed on any magnetic surface such as a
refrigerator or the Zephyr remote holder, FIG. 1. The remote holder can
be inserted into a standard electrical outlet for easy storage. Note: The
remote holder does not charge the RF remote.
Maximum remote control communication distance is 15 feet from the hood.
REMOTE PAIRING: Tocreateauniquelinkbetweenyourhoodandremotecontrolpleasefollowthesesteps:
1.Withhoodo,pressandholdthe“lights”buttononthehooduntil“RemotePairing”showsonthedisplayscreen. 
2.Presstheanybuttonontheremote,thedispalywillshow“RemotePaired”indicatingthepairingiscomplete.
RF REMOTE FUNCTIONS:
FIG. 1
FIG. 2
Blower On / Speed Selection
Press to power on blower and cycle through all six blower speeds.
Blower On / Power Off
By pressing , the blowers will power on at the last speed setting. Press
again and the entire hood will power off, including lights.
Delay Off
Lights On / Dim / Off
Switch lights On by pressing once, again to dim and again to switch Off.
Blower On/
Speed Selection
1
1
2
3
4
Blower On/
Power Off
2
10 Min Delay Off
3
Lights On/Dim/Off
4
By pressing , the blower and lights will enter Delay Off mode.
The blower will
change to speed 1 and shut down after 10 minutes.
A
-
+
FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compli-
ance could void the user’s authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer
or peripheral device. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. (1) This device
may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause
undesired operation.
THE RF REMOVE CONTROL IS AN OPTIONAL
ACCESSORY NOT INCLUDED WITH THE HOOD AND
MUST BE PURCHASED SEPARATELY
Features & Controls – Optional Remote Control
13
SURFACE MAINTENANCE:
Do not use corrosive detergents, abrasive detergents or oven cleaners.
Do not use any product containing chlorine bleach or any product containing chloride.
Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface.
Cleaning Stainless Steel
Cleanperiodicallywithwarmsoapywaterandcleancottonclothormicrobercloth.Alwaysrubinthedirectionofthestainless
steel grain. To remove heavier grease build up use a liquid degreaser detergent.
Aftercleaninguseanon-abrasivestainlesssteelpolish/cleaners,topolishandbuoutthestainlesslusterandgrain.Always
scrublightly,withcleancottonclothormicroberclothandbuinthedirectionofthestainlesssteelgrain.
Stainless Steel Bae Filters
Thestainlesssteelbafeltersareintendedtotrapresidueandgreasefromcooking.Althoughtheltersshouldneverneed
replacing,theyarerequiredtobecleanedevery30daysormoreoftendependingoncookinghabits.
FiltersmaybeplacedindishwasheratlowheatorsoakedinhotsoapywaterDryltersandre-installbeforeusinghood.
Removing Bae Filters
1. Pushltertowardbackofrangehoodusinghandles.
2. Pivotfrontoflterdownward.
3. Removelterbypullingawayfromhood.
Cleaning the Grease Tray
Thegreasetrayisintendedtocatchresidueandgreasethatmaydripfromthebaelters.Thegreasetrayshouldbecleaned
whenbaeltersarecleaned.Cleanthegreasetraybysoakinginhotsoapywaterandgentlyscrubinganyresidueowitha
soft terry cloth. Dry grease tray and re-install before using hood.
REPLACING LIGHT BULBS
Makesureallpoweristurnedo. 
Removebyturningbulbcounterclockwise.Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. If bulbs are
diculttoturnduetoprolongeduse,rmlyattachaglasssuctioncupapproximatelythediameterofthebulborusearubber/
latexgloveandturncounterclockwise.FIG.3.
Directional Lighting
Thelightbulbscanbetiltedforwardsandbackwardstobetterdirectlightoveryourcookingsurface.FIG.4.
Replacement bulbs are available to purchase directly from Zephyr. Purchase online at http://store.zephyronline.com or call us at
1.888.880.8368
.
1
2
3
Maintenance – Cleaning, Filter Removal & Lights
FIG. 3 FIG. 4
14
www.zephyronline.com
TROUBLESHOOTING PROCEDURES
Issue Cause What to do
After installation,
the unit doesn’t
work.
1. The power source is not turned ON. 1. Makesurethecircuitbreakerandtheunit’s
power is ON.
2. Thepowerlineandthecablelockingconnector
is not connecting properly.
2. Checkthepowerconnectionwiththeunitis
connected properly.
3. The switch board and control board wirings are
disconnected.
3. Makesurethewiringsbetweentheswitch
board and control board are connected
properly.
4. The wires on control board are loose. 4. Makesurethewiresonthecontrolboardare
connected properly.
5. The switch board or control board is defective. 5. Change the switch board or control board.
Lightworks,but
the blower is not
turning.
1. The blower is defective, possible seized. 1. Change the blower.
2. The thermally protected system detects if the
blower is too hot to operate and shuts the blower
down.
2. The blower will function properly after the
thermally protected system cool down.
3. Damaged capacitor. 3. Change the capacitor.
4. The blower wire is not connected. 4. Makesuretheblowerwireispluggedintothe
molex connector.
The unit is
vibrating.
1. The blower is not secure in place. 1. Tighten the blower in place.
2. Damaged blower wheel. 2. Change the blower.
3. The hood is not secured in place. 3. Checktheinstallationofthehood.
The blower is
working,butthe
lights are not.
1. Defective halogen bulb. 1. Change the halogen bulb.
2. The light bulb is loose. 2. Tighten the light bulb.
3. The light bulb plug is disconnected. 3. Checkthelightbulbplugconnection.
The hood is
not venting out
properly.
1. The hood might be hanging to high from the
cooktop.
1. Adjustthedistancebetweenthecooktopand
the bottom of the hood within 24” and 34”
range.
2. The wind from the opened windows or opened
doorsinthesurroundingareaareaectingthe
ventilation of the hood.
2. Close all the windows and doors to eliminate
theoutsidewindow.
3. Blockageintheductopeningorductwork. 3. Removealltheblockingfromtheductworkor
duct opening.
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.
5. Using the wrong size of ducting. 5. Change the ducting to correct size.
Metallteris
vibrating.
1. Metallterisloose. 1. Changethemetallter.
2. Springclipisbroken. 2. Change the spring clip.
The blower turns
on by itself.
1. The clean air function has been enabled turning
the blower on every 4 hours.
1. Disable the clean air function by following the
steps on page 11.
Troubleshooting
15
Airow Control Technology (ACT™)
Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the
maximumblowerCFMofselectZephyrVentilationrangehoodswithouttheneedforexpensivemakeupairkits.
ACTenablestheinstallertoeasilysetthemaximumblowerspeedtooneoftwomostcommonlyspeciedCFM
levels; 590, 390 or 290 CFM. The usage of ACTmaynotbenecessaryforyourinstallation.Pleasecheckyour
local codes for CFM restrictions.
By default the maximum blower CFM is set to 750.
ACT™ NOT AVAILABLE WITH 1300 CFM DUAL INTERNAL BLOWER OPTION
To enable ACT™
1. Before hood installation, gain access to PC board by following the steps shown in FIG. C.
2. Change plastic jumper positioning as shown in FIG. D to set the desired maximum blower CFM.
3. Re-install PC board & continue with hood installation.
4.RemovetheappropriatefoilCFMstickerincludedwiththehoodliteratureandplaceinsidethehoodbodybelow
the wiring diagram or in another clearly visible location.
NOTE: After re-positioning the jumper and powering on the hood, the CFM cannot be changed again.
To verify if your installer enabled ACT™
Withhoodo,holdtheOn/Obuttonforthreeseconds.TheDisplaywillshowifACT™isdisabledandsettothe
maximumCFMorifACT™isenabledandsettooneoftherestrictedmaximumCFMlevelsof590,390or290.
There should also be a foil label located inside the hood body near the wiring diagram that indicates the blower CFM.
ACT™ Conversion
1 3 5 7
2 4 6 8
1 3 5 7
2 4 6 8
1 3 5 7
2 4 6 8
1 3 5 7
2 4 6 8
Max. Blower CFM 750
Jumper 7-8
DEFAULT POSITION
Max. Blower CFM
590
Jumper 5-6
Max. Blower CFM
390
Jumper 3-4
Max. Blower CFM
290
Jumper 1-2
1 3 5 7
2 4 6 8
PC Board
Jumper Pins
Plastic
Jumper
FIG. C
FIG. D
Models: AK76
- Locate PC board box on top of blower housing.
- Remove 4 screws attaching PC board cover.
www.zephyronline.com
16
Wiring Diagrams
ACT 590 CFM - Fan Max. 175W @ 2.6A
ACT 390 CFM - Fan Max. 94W @ 1.4A
ACT 290 CFM - Fan Max. 63W @ 0.9A
17
DESCRIPTION PART #
Replacement Parts
LEDLightBulbMR16(GU10)6W(each) Z0B0040
BaeFilter(each) 50210033
Optional Accessories
Dual Internal Blower PBD-1300A
Duct Cover Extension Z1C-00RP
Make-UpAirKit(SingleBlower) MUA008A
Make-UpAirKit(DualBlower) MUA010A
To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368
List of Parts and Accessories
18
www.zephyronline.com
Warranty
OCT17.0301
ZephyrVentilation,LLC(referredtohereinas“we”or“us”)warrantstotheoriginalconsumerpurchaser(referredtoherein
as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or
workmanshipasfollows:
Three Year Limited Warranty for Parts: For three years from the date of your original purchase of the Products, we will
provide, free of charge, Products or parts (including LED light bulbs, if applicable) to replace those that failed due to
manufacturing defects subject to the exclusions and limitations below. We may choose, in our sole discretion, to repair or
replace parts before we elect to replace the Products.
One Year Limited Warranty for Labor: For one year from the date of your original purchase of the Products, we will
provide, free of charge, the labor cost associated with repairing the Products or parts to replace those that failed due to
manufacturing defects subject to the exclusions and limitations below. After the first year from the date of your original
purchase, you are responsible for all labor costs associated with this warranty.
Warranty Exclusions: This warranty covers only repair or replacement, at our option, of defective Products or parts and
does not cover any other costs related totheProductsincludingbutnotlimitedto:(a)normalmaintenanceandservice
required for the Products and consumable parts such as fluorescent, incandescent or halogen light bulbs, mesh and char-
coalfiltersandfuses;(b)anyProductsorpartswhichhave been subject to freight damage, misuse, negligence, accident,
faulty installation or installation contrary to recommended installationinstructions,impropermaintenanceorrepair(other
thanbyus);(c)commercialorgovernmentuseoftheProductsoruseotherwiseinconsistentwithitsintendedpurpose;(d)
natural wear of the finish of the Products or wear caused by improper maintenance, use of corrosive and abrasive cleaning
products, pads, and oven cleanerproducts;(e)chips,dentsorcrackscausedbyabuseormisuseoftheProducts;(f)service
trips to your home to teach you how to usetheProducts;(g)damagetotheProductscausedbyaccident,fire,floods,acts
ofGod;or(h)Custominstallations or alterations that impact serviceability of the Products. If you are outside our service
area, additional charges may apply for shipping costs for warranty repair at our designated service locations and for the
travel cost to have a service technician come to your home to repair, remove or reinstall the Products. After the first year
from the date of your original purchase, you are also responsible for all labor costs associated with this warranty. All Products
must be installed by a qualified professional installer to be eligible for warranty repairs or service.
Limitations of Warranty. OUR OBLIGATION TO REPAIR OR REPLACE, AT OUR OPTION, SHALL BE YOUR SOLE
AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. WE SHALL NOT BE LIABLE FOR INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR
PERFORMANCE OF THE PRODUCTS. THE EXPRESS WARRANTIES IN THE PRECEDING SECTION ARE
EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. WE HEREBY DISCLAIM AND EXCLUDE ALL
OTHER EXPRESS WARRANTIES FOR THE PRODUCTS, AND DISCLAIM AND EXCLUDE ALL WARRANTIES
IMPLIED BY LAW, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Some states or provinces do not allow limitations on the duration of an implied warranty or the exclusion or limitation of
incidental or consequential damages, so the above limitations or exclusions may not apply to you. To the extent that
applicable law prohibits the exclusion of implied warranties, the duration of any applicable implied warranty is limited to the
same three-year and one-year periods described above if permitted by applicable law. Any oral or written description of the
Products is for the sole purpose of identifying the Products and shall not be construed as an express warranty. Prior to
using, implementing or permitting use of the Products, you shall determine the suitability of the Products for the intended
use, and you shall assume all riskandliabilitywhatsoeverinconnection with such determination. We reserve the right to
use functionally equivalent refurbished or reconditioned parts or Products as warranty replacements or as part of warranty
service. This warranty is not transferable from the original purchaser and only applies to the consumer residence where the
Product was originally installed located in the United States and Canada. This warranty is not extended to resellers.
To Obtain Service Under Limited Warranty: Toqualifyforwarrantyservice,youmust:(a)notifyusattheaddressor
telephone number stated below within 60 days of the discovery ofthedefect;(b)givethemodelnumberandserialnumber;
and(c)describethenatureofanydefectintheProductorpart.At the time of the request for warranty service, you must
present evidence of your proof of purchase and proof of the original purchase date. If we determine that the warranty
exclusions listed above apply or if you fail to provide the necessary documentation to obtain service, you will be responsible
for all shipping, travel, labor and other costs related to the services. This warranty is not extended or restarted upon warranty
repair or replacements.
PleasecheckourwebsiteforanyadditionalProductinformation,www.zephyronline.com.
Zephyr Ventilation Service Department, 2277 Harbor Bay Parkway, Alameda, CA 94502 1-888-880-8368
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

Zephyr ZRP-E48AS Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues