GE AEM10AN Le manuel du propriétaire

Taper
Le manuel du propriétaire

Ce manuel convient également à

Safety Instructions ................... 2, 3
Operating Instructions
............. 4, 5
Care and Cleaning
Air Filter .............................................................6
Outdoor Coils ..................................................6
Installation Instructions ......7–12
Troubleshooting Tips ................. 14
Normal Operating Sounds ....................14
Consumer Support
Consumer Support ................. Back Cover
Ownership Registration for
Customers in Canada only ...........15, 16
Warranty for Customers
in Canada ......................................................17
Warranty for Customers
in the U.S.A. ...................................................18
49-7623 12-09 GE
AEM10*
AEM12*
Owner’s Manual and
Installation Instructions
Write the model and serial numbers here:
Model # _________________________
Serial # __________________________
Find these numbers on a label on the side of
the air conditioner.
Air Conditioners
GEAppliances.com
Room
As an EnErgy Star® partner, GE has
determined that this product meets
the EnErgy Star® guidelines for
energy efficiency.
*EnErgy Star® labeled product
Climatiseur
Acondicionador
de aire
Manuel d’utilisation et
instructions d’installation
Manual del propietario
y instrucciones de
instalación
La section française commence à la page 19
La sección en español empieza en la página 35
2
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric
shock or personal injury.
n Use this appliance only for its intended
purpose as described in this Owner’s
Manual.
n This air conditioner must be properly
installed in accordance with the Installation
Instructions before it is used.
n Never unplug your air conditioner by pulling
on the power cord. Always grip plug firmly
and pull straight out from the receptacle.
n Replace immediately all electric service
cords that have become frayed or otherwise
damaged. A damaged power supply cord
must be replaced with a new power supply
cord obtained from the manufacturer and
not repaired. Do not use a cord that shows
cracks or abrasion damage along its length
or at either the plug or connector end.
n If the receptacle does not match the plug,
the receptacle must be changed out by a
qualified electrician.
n Turn the unit OFF and unplug your air
conditioner before making any repairs
or cleaning.
NOTE: We strongly recommend that any
servicing be performed by a qualified
individual.
n For your safety…do not store or use
combustible materials, gasoline or other
flammable vapors or liquids in the vicinity
of this or any other appliance.
n All air conditioners contain refrigerants,
which under federal law must be removed
prior to product disposal. If you are getting
rid of an old product with refrigerants, check
with the company handling disposal about
what to do.
n These R410A air conditioning systems
require contractors and technicians to use
tools, equipment and safety standards
approved for use with this refrigerant.
DO NOT use equipment certified for R22
refrigerant only.
SAFETY PRECAUTIONS
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
For personal safety, this appliance must be
properly grounded.
DO NOT use an adapter plug with this
appliance.
The power cord of this appliance is equipped
with a 3-prong (grounding) plug which mates
with a standard 3-prong (grounding) wall outlet
to minimize the possibility of electric
shock hazard from this appliance.
Power cord includes a current interrupter device.
A test and reset button is provided on the plug
case. The device should be tested on a periodic
basis by first pressing the TEST button and then
the RESET button while plugged into the outlet. If
the TEST button does not trip
or if the RESET button will not stay engaged,
discontinue use of the air conditioner and
contact a qualified service technician.
Have the wall outlet and circuit checked by
a qualified electrician to make sure the outlet
is properly grounded.
Where a 2-prong wall outlet is encountered,
it is your personal responsibility and obligation to
have it replaced with a properly grounded
3-prong wall outlet.
The air conditioner should always be plugged
into its own individual electrical outlet which has
a voltage rating that matches the rating plate.
This provides the best performance and also
prevents overloading house wiring circuits which
could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical
Requirements section for specific electrical
connection requirements.
HOW TO CONNECT ELECTRICITY
Safety Instructions
Operating
Instructions
Care and Cleaning
Installation
Instructions
Troubleshooting
Tips
Consumer Support
3
Consumer Support
Troubleshooting
Tips
Installation
Instructions
Care and Cleaning
Operating
Instructions
Safety Instructions
GEAppliances.com
WARNING!
Because of potential safety hazards under certain
conditions, we strongly recommend against the
use of an extension cord.
However, if you must use an extension cord,
it is absolutely necessary that it be a UL-listed,
14 gauge, 3-wire grounding type appliance
extension cord having a grounding type plug
and outlet and that the electrical rating of the
cord be 15 amperes (minimum) and 125 volts.
CAUTION:
DO NOT use an extension cord with any of the
230/208 volt models.
USE OF EXTENSION CORDS—115-Volt models only
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
4
About the controls on the air conditioner
Controls
Power Pad
Turns air conditioner on and off. When turned
on, the display will show the room temperature.
Display
Shows the room temperature or time remaining
on the Delay timer. Shows the Set temperature
while setting the temperature in Cool or Energy
Saver modes. The Set light will turn on while
setting.
NOTE: The display will change to show the room
temperature after settings have been made.
To recall the Set temperature, press the Temp
Increase or Decrease pads.
Temp Increase /DecreasePads
Use to set temperature when in Cool or Energy
Saver mode. The Set light will turn on while
setting.
Delay Timer Increase (+) /Decrease(–)
Pads
Each touch of the Increase / Decrease pads
on the unit or the Increase + / Decrease pads
on the remote control will set the delay time
when using the Delay 1–24hr timer (+). The Set
light will turn on while setting.
Fan Speed Pads
Use to set the fan speed to Low, Med, High
or Auto on the unit. NOTE: On the remote
control, use the fan speed Increase + /
Decrease pads to set the fan speeds to Low,
Med or High. Use the Auto pad to turn Auto
fan on.
Mode Pad
Use to set the air conditioner to Cool, Energy
Saver or Fan Only mode.
Delay Pads
Delay ON—When the air conditioner is off, it can
be set to automatically come on in 1 to 24 hours
at its previous mode and fan settings.
Delay OFF—When the air conditioner is on,
it can be set to automatically turn off in 1 to
24 hours.
How to set:
Press the Delay 1–24hr pad on the unit or the
+ pad on the remote control. Each touch of the
Increase / Decrease pads on the unit or the
Increase + / Decrease pads on
the remote control will set the timer in
1-hour intervals. The Set light will turn on while
setting.
To review the remaining time on the Delay
1–24hr timer, press the Delay 1–24hr pad on the
unit or the
+ pad on the remote control. Use the
Increase / Decrease pads on the unit or the
Increase + / Decrease pads on the remote
control to set a new time if desired.
To cancel the timer, press the Delay
1–24hr pad until the light on the Delay 1–24hr
pad goes off.
Features and appearance will vary.
Lights next to the touch pads on the air conditioner control panel indicate the selected settings.
The display always shows
the room temperature
except when setting the
Set temperature or the
Delay timer.
Air Conditioner Controls
Light indicates the delay timer is set.
Light indicates the unit
is in the temperature or
delay time Set mode.
In the case of a power outage or interruption, the
unit will automatically re-start in the settings last
used after the power is restored. If the Delay 1–24hr
feature was set, it will resume countdown. You may
need to set a new time if desired.
Power Outage Recovery Feature
Safety Instructions
Operating
Instructions
Care and Cleaning
Installation
Instructions
Troubleshooting
Tips
Consumer Support
Remote Control
FanFan
5
GEAppliances.com
Cool Mode
Use the Cool mode at Low, Med, High or Auto Fan
Speed for cooling. Use the Temperature Increase
/ Decrease pads to set the desired temperature
between 64°F and 86°F in 1°F increments.
An electronic thermostat is used to maintain the room
temperature. The compressor will cycle on
and off to keep the room at the set level of comfort.
Set the thermostat at a lower number and the indoor
air will become cooler. Set the thermostat at a higher
number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on
while set to a Cool setting or if turned from a fan
setting to a Cool setting, it may take approximately
3 minutes for the compressor to start and cooling to
begin.
Cooling Descriptions
For Normal Cooling—Select the Cool mode and
High or Med fan with a middle set temperature.
For Maximum Cooling—Select the Cool mode
and High fan with a lower set temperature.
For Quieter & Nighttime Cooling—Select the
Cool mode and Low fan with a middle set
temperature.
Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for
freezing outdoor conditions. It must not be used in
freezing outdoor conditions.
Fan Only Mode
Use the Fan Only Mode at Low, Med or High fan
speed to provide air circulation and filtering without
cooling. Since fan only settings do not provide cooling,
a Set temperature cannot be entered. The room
temperature will appear in the display.
NOTE: Auto Fan Speed cannot be used when in the
Fan Only Mode.
Energy Saver Mode
Controls the fan.
ON—The fan will cycle on and off with the
compressor. This results in wider variations of room
temperature and humidity. Normally used when the
room is unoccupied. NOTE: The fan may continue to
run for a short time after the compressor cycles off.
OFF—The fan runs all the time, while the compressor
cycles on and off.
Set to Auto fan speed for the fan speed to
automatically set to the speed needed to provide
optimum comfort settings with the set temperature.
If the room needs more cooling, the fan speed
will automatically increase. If the room needs less
cooling, the fan speed will automatically decrease.
NOTE: Auto Fan Speed cannot be used when in the
Fan Only Mode.
Auto Fan Speed
n To ensure proper operation, aim the remote
control at the signal receiver on the air
conditioner.
n The remote control signal has a range of
up to 20 feet.
n Make sure nothing is between the air conditioner
and the remote control that could block the
signal.
n Make sure batteries are fresh and installed
correctly as indicated on the remote control.
Remote Control
Consumer Support
Troubleshooting
Tips
Installation
Instructions
Care and Cleaning
Operating
Instructions
Safety Instructions
Use the levers to adjust the air direction left and right.
Fingertip pressure on the louver banks adjusts the air
direction up or down.
Air Direction
Outdoor Coils
The coils on the outdoor side of the air conditioner
should be checked regularly. If they are clogged with
dirt or soot, they may be professionally cleaned.
6
Turn the air conditioner off and remove the plug from
the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use
bleach or abrasives.
Grille and Case
Care and cleaning of the air conditioner.
Safety Instructions
Operating
Instructions
Care and Cleaning
Installation
Instructions
Troubleshooting
Tips
Consumer Support
1
Remove the battery cover by sliding it according
to the arrow direction.
2
Insert new batteries, making sure that the (+)
and (–) of battery are installed correctly.
3
Reattach the cover by sliding it back
into position.
NOTES:
n Use 2 “AAA” (1.5 volt) alkaline batteries. Do not
use rechargeable batteries.
n Remove the batteries from the remote control if
the system is not going to be used for a long time.
n Do not mix old and new batteries. Do not mix
alkaline, standard (carbon-zinc) or rechargeable
(ni-cad, ni-mh, etc) batteries.
How to Insert the Batteries in the Remote Control
Air Filter
The air filter behind the front grille should be checked
and cleaned at least every 30 days or
more often if necessary.
To remove:
Open the inlet grille by pulling downward on the tabs
at the top upper corners of the inlet grille until the
grille is in a 45° position. Remove the filter.
Clean the filter with warm, soapy water. Rinse and let
the filter dry before replacing it. Do not clean the filter
in a dishwasher.
CAUTION: DO NOT operate the air
conditioner without a filter because dirt and lint will
clog it and reduce performance.
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
IMPORTANT Save these instructions
for local inspector’s use.
IMPORTANT Observe all governing
codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these instructions for
future reference.
Skill level – Installation of this appliance requires
basic mechanical skills.
Completion time –
Approximately 1 hour
We recommend that two people install
this product.
Proper installation is the responsibility
of the installer.
Product failure due to improper installation is not
covered under the Warranty.
You MUST use all supplied parts and use proper
installation procedures as described in these
instructions, and any separate kit instructions,
when installing this air conditioner.
Installation
Air Conditioner
Instructions
Some models require a 115/120-volt AC,
60 Hz grounded outlet protected with a
15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility
of electric shock hazard. If the wall outlet you plan to
use is only a 2-prong outlet,
it is your responsibility to have it replaced with
a properly grounded 3-prong wall outlet.
Some models require 230/208-volt AC,
protected with a time delay fuse or circuit
breaker. These models should be installed
on their own single branch circuit for best
performance and to prevent overloading
house or apartment wiring circuits, which
could cause a possible fire hazard from
overheating wires.
ELECTRICAL REQUIREMENTS
CAUTION:
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
Do not change the plug on the power cord
of this air conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
If the sill support bolts do not contact the
window sill, or if you have a window without
a sill, you must order accessory kit RAK87
to properly install this air conditioner. Call
800.626.2002 or visit GEAppliances.com.
Power cord includes a current interrupter device. A
test and reset button is provided on the plug case. The
device should be tested on a periodic basis by first
pressing the TEST button and then the RESET button
while plugged into the outlet. If the TEST button does
not trip or if the RESET button will not stay engaged,
discontinue use of the air conditioner and contact a
qualified service technician.
7
TOOLS YOU WILL NEED
Phillips head screwdriver
Ruler or tape measure
Pencil
Level
Scissors or knife
Adjustable wrench
Flat-blade screwdriver
Questions? Call 800.GE.CARES (800.432.2737) or visit our Website at: GEAppliances.com
In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
8
Type A (6)
Type B (7)
Right
accordion
panel
Window sash seal
(thin, adhesive-backed)
Foam top
window gasket
Window locking
bracket (2)
Left accordion
panel
Top mounting rail
Installation Instructions
PARTS INCLUDED
(appearance may vary)
Type C (6)
Type D (3)
Top mounting rail
seal strip
Sill support (2)
Nut (2)
Bolt (2)
Installation Instructions
WINDOW REQUIREMENTS
These instructions are for a standard
double-hung window. You will need to modify
them for other types of windows.
CAUTION:
If the sill support
bolts do not contact the window sill, or
if you have a window without a sill, you
must order accessory kit RAK87 to
properly install this air conditioner.
Call 800.626.2002 or visit GEAppliances.com.
The air conditioner can be installed without
the accordion panels if needed to fit in a
narrow window. See the window opening
dimensions.
All supporting parts must be secured
to firm wood, masonry or metal.
The electrical outlet must be within reach of
the power cord.
1
15 7/16” min.
25 1/4 to 38
(With accordion panels)
REMOVE THE AIR CONDITIONER
FROM THE CASE
Remove and save the 2 screws from the lower
sides of the front grille.
Grasp the lower corners of the grille while
pressing in on the case sides with your finger
tips. Pull out to release and lift it up.
NOTE: Do not pull the bottom edge toward you
more than 3 or you may damage the tabs of
the grille.
Remove the ground screw from each side of
the case. Keep them in a safe location.
NOTE: Be sure to save these screws. You will
need them later in the installation.
Slide the air conditioner from the case by
gripping the base pan handle and pulling
forward while bracing the case. Do not pull or
lift on the styrofoam discharge area.
3
A
C
FRONT
FRONT
Do not
pull or
lift in this
area—
damage
to the
unit may
result
D
STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will keep
it from draining properly. To adjust for this, attach
a piece of wood to the sill.
WOOD PIECES –
WIDTH: 2
LENGTH: Long enough to fit inside the window
frame.
THICKNESS: To determine the thickness, place a
piece of wood on the sill to make it 1/2 higher
than the top of the storm window frame or the
vinyl frame.
Attach securely with nails or screws provided
by the installer.
2
1/2higher
than storm
window
frame
Storm window
frame
Wood
Sill
1/2higher
than vinyl frame
(on some windows)
Vinyl frame
9
FRONT
FRONT
B
2
Installation Instructions
10
INSTALL THE TOP MOUNTING RAIL
ONTO THE CASE
Attach the top mounting rail onto the top of the
case with 3 Type B screws.
5
Type B
screws
Top
mounting
rail
INSTALL THE
SIDE ACCORDION PANELS
Slide the left and right accordion panels into
the top and bottom mounting rails.
Attach the accordion panels to the case using 3
Type A screws on each side.
6
A
B
Type A
screws
Top mounting rail
Bottom mounting rail
Accordion
panel
PREPARE THE WINDOW
Cut the window sash seal to the window
width and stick the adhesive side to the
bottom of the sash.
7
Window sash
seal
BACK
INSIDE
4
Top mounting rail
Remove
backing
from seal
strip
3/8 overlap 3/8 overlap
Top mounting rail
Seal strip
FRONT VIEW
ATTACH THE TOP MOUNTING RAIL
SEAL STRIP
Remove the backing from the top mounting rail
seal strip and attach the seal strip to the bottom
of the top maounting rail, along the front edge.
Installation Instructions
INSTALL THE CASE IN THE WINDOW
Open the window and mark the centerline of
the window sill.
Carefully place the case on the window stool
and align the center mark on the bottom front
with the centerline of the sill.
Pull the window down behind the top mounting
rail.
NOTE: Do not shut the window so tightly that
movement of the accordion panels is
restricted.
Select the position that will place the sill
supports near the outermost point on the sill.
Place the short side of the sill supports, on the
case bottom, toward the window. Attach the sill
supports to the case track hole in relation to the
selected position using 2 Type B screws in each
support.
CAUTION: Do not install this air
conditioner in a window if the bolts do not
contact the window sill.
Adjust the bolt and the nut in each support so
that the case is installed with a slight tilt to the
outside. Use a level; no more than 1/2 bubble
will be the correct case slant to the outside.
CAUTION: If the sill support bolts
do not contact the window sill or if you have a
window without a sill you must order accessory
kit RAK87 to properly install this air conditioner.
Call 800.626.2002 or visit GEAppliances.com.
8
INSTALL THE CASE IN THE WINDOW
(CONT.)
Secure the case to the window sill by using 3
Type D screws.
Pull the accordion panels to each window sash
track. Attach them on each side to the window
sash and the window sill using
4 Type C screws.
8
A
B
C
F
G
11
D
Long side of
sill supports
OUTSIDE
E
Installation Instructions
INSTALL THE AIR CONDITIONER
IN THE CASE (CONT.)
Replace the 2 ground screws removed earlier,
one on each side of the case.
IMPORTANT: The ground screws must be
reinstalled to ensure a proper ground.
Attach the front grille to the case by inserting
the tabs on the grille into the slots on the front
top of the case. Push the grille in.
Secure the front grille to the case by replacing
the 2 screws removed earlier. Press on the top
of the grille to help
with side screw installation.
Connect power.
10
B
C
INSTALL THE AIR CONDITIONER
IN THE CASE
Slide the air conditioner into the case by
the base pan. Do not push on the controls,
styrofoam air discharge housing or the finned
coils. Make sure the air conditioner is firmly
seated.
10
A
E
D
Do not press on
these areas—
damage to the unit
may result
Base Pan
12
9
INSTALL SUPPORT BRACKET AND
FOAM TOP WINDOW GASKET
Attach the support bracket
with one Type C screw.
Cut the foam top window gasket to the window
width.
Stuff the foam
between the glass
and the window
to prevent air and
insects from getting
into the room.
NOTE: If the gasket supplied does not fit your
window, obtain appropriate material locally to
provide a proper installation seal.
A
CAUTION:
To prevent broken glass or
damage to windows, on
vinyl or other similarly
constructed windows,
attach the support bracket
to the window side jam.
B
C
Wood
Vinyl
Consumer Support
Troubleshooting
Tips
Installation
Instructions
Care and Cleaning
Operating
Instructions
Safety Instructions
Troubleshooting Tips.
Normal Operating Sounds
n You may hear a pinging noise caused by
water being picked up and thrown against the
condenser on rainy days or when the humidity
is high. This design feature helps remove
moisture and improve efficiency.
n You may hear the thermostat click when the
compressor cycles on and off.
n Water will collect in the base pan during
high humidity or on rainy days. The water
may overflow and drip from the outdoor side
of the unit.
n The fan may run even when the compressor
does not.
Problem Possible Causes What To Do
Air conditioner The air conditioner Make sure the air conditioner plug is pushed
does not start is unplugged. completely into the outlet.
The fuse is blown/circuit Check the house fuse/circuit breaker box and replace
breaker is tripped. the fuse or reset the breaker.
Power failure. The unit will automatically re-start in the settings last
used after the power is restored.
There is a protective time delay (approximately
3 minutes) to prevent tripping of the compressor
overload. For this reason, the unit may not start
normal cooling for 3 minutes after it is turned
back on.
The current interrupter Press the RESET button located on the power cord plug.
device is tripped.
If the RESET button will not stay engaged, discontinue
use of the air conditioner and contact a qualified
service technician.
Air conditioner does Airflow is restricted. Make sure there are no curtains, blinds or furniture
not cool as it should blocking the front of the air conditioner.
The temp control may On models with touch pads: In the Cool mode, press the
not be set correctly. Decrease pad.
On models with control knobs, turn the temperature
knob to a higher number.
The air filter is dirty. Clean the filter at least every 30 days.
See the Care and Cleaning section.
The room may have been hot. When the air conditioner is first turned on, you need
to allow time for the room to cool down.
Cold air is escaping. Check for open furnace registers and cold air returns.
Cooling coils have iced up. See “Air conditioner freezing up” below.
Air conditioner Ice blocks the air flow On models with control knobs, set the mode control at
freezing up and stops the air conditioner High Fan or High Cool with the Temp at 1 or 2.
from cooling the room.
On models with touch pads, set the controls at High Fan
or High Cool and set the thermostat to a higher
temperature.
The remote control The batteries are inserted Check the position of the batteries. They should be
is not working incorrectly. inserted in the opposite (+) and (–) direction.
The batteries may be dead. Replace the batteries.
Water drips outside Hot, humid weather. This is normal.
Water drips indoors The air conditioner is not For proper water disposal, make sure the air conditioner
tilted to the outside. slants slightly from the case front to the rear.
Water collects in Moisture removed from air This is normal for a short period in areas with little
base pan and drains into base pan. humidity; normal for a longer period in very humid areas.
14
Notes.
Safety Instructions
Operating
Instructions
Care and Cleaning
Installation
Instructions
Troubleshooting
Tips
Consumer Support
15
OWNERSHIP REGISTRATION
P.O. BOX 1780
MISSISSAUGA, ONTARIO
L4Y 4G1
(FOR CANADIAN CONSUMERS ONLY)
Please place in envelope and mail to:
Veuillez mettre dans une enveloppe et envoyez à :
16
17
Consumer Support
Troubleshooting
Tips
Installation
Instructions
Care and Cleaning
Operating
Instructions
Safety Instructions
Staple your receipt here.
Proof of the original purchase
date is needed to obtain
service under the warranty.
GE Air Conditioner—One-Year Limited Warranty. (For customers in the U.S.A.)
For The Period Of: GE Will Replace:
One Year Any part of the air conditioner which fails due to a defect in materials or workmanship.
From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor and related
original purchase service to replace the defective part.
All warranty service provided by our Factory Service Centers,
or an authorized Customer Care
®
technician. To schedule service,
visit us on-line at GEAppliances.com, or call 800.GE.CARES
(800.432.2737). Have serial number and model number available
when calling for service.
n Service trips to your home to teach you how to
use the product.
n Improper installation, delivery or maintenance. If you
have an installation problem, or if the air conditioner
is of improper cooling capacity for the intended use,
contact your dealer or installer. You are responsible
for providing adequate electrical connecting facilities.
n Failure of the product resulting from modifications to
the product or due to unreasonable use including failure
to provide reasonable and necessary maintenance.
n In commercial locations, labor necessary to move the
unit to a location where it is accessible for service
by an individual technician.
n Replacement of house fuses or resetting of circuit
breakers.
n Failure due to corrosion on models not corrosion-
protected.
n Damage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.
n Incidental or consequential damage caused by possible
defects with this air conditioner.
n Damage caused after delivery.
What Is Not Covered:
This warranty is extended to the original purchaser and any succeeding owner for products purchased for
home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is
not available, you may be responsible for a trip charge or you may be required to bring the product to an
Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service
calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty
gives you specific legal rights, and you may also have other rights which vary from state to state. To know
what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
Warrantor: General Electric Company. Louisville, KY 40225
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in
this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or
fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
18
Staple your receipt here.
Proof of the original purchase
date is needed to obtain
service under the warranty.
GE Air Conditioner—One-Year Limited Warranty. (For customers in the Canada)
For The Period Of: Mabe Will Replace:
One Year Any part of the air conditioner which fails due to a defect in materials or workmanship.
From the date of the During this limited one-year warranty, Mabe will also provide, free of charge, all labor and
original purchase related service to replace the defective part.
All warranty service provided by our Factory Service Centers,
or an authorized Customer Care
®
technician. For service, call
1.800.561.3344. Please have serial number and model number
available when calling for service.
n Service trips to your home to teach you how to
use the product.
n Improper installation, delivery or maintenance. If you
have an installation problem, or if the air conditioner
is of improper cooling capacity for the intended use,
contact your dealer or installer. You are responsible
for providing adequate electrical connecting facilities.
n Failure of the product resulting from modifications to
the product or due to unreasonable use including failure
to provide reasonable and necessary maintenance.
n In commercial locations, labor necessary to move the
unit to a location where it is accessible for service
by an individual technician.
n Replacement of house fuses or resetting of circuit
breakers.
n Failure due to corrosion on models not corrosion-
protected.
n Damage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.
n Incidental or consequential damage caused by possible
defects with this air conditioner.
n Damage caused after delivery.
What Is Not Covered:
This warranty is extended to the original purchaser and any succeeding owner for products purchased in
Canada for home use within Canada. In-home warranty service will be provided in areas where it is available
and deemed reasonable by Mabe to provide.
Some provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above
exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other
rights which vary from province to province. To know what your legal rights are in your province, consult your
local or provincial consumer affairs office.
Warrantor: Mabe Canada Inc.,
Burlington, Ontario
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in
this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or
fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
Safety Instructions
Operating
Instructions
Care and Cleaning
Installation
Instructions
Troubleshooting
Tips
Consumer Support
Consignes de sécurité ..........20, 21
Consignes d’utilisation
Modèles dotés touches
à effleurement ....................22, 23
Entretien et nettoyage
Filtre à air ..........................24
Serpentins extérieurs .................24
Instructions de montage ........25–30
Conseils de dépannage ............31
Bruits normaux de fonctionnement .....31
Assistance à la clientèle
Assistance à la clientèle ................36
Garantie ............................35
Enregistrement du titre
de propriété .....................33, 34
Inscrivez ici les numéros de modèle et de série :
Numéro de modèle : _______________________
Numéro de Série : _______________________
Vous trouverez ces numéros sur l’étiquette
apposée sur le côté du climatiseur.
En tant que partenaire d’ENERGY
STAR
®
, GE a déterminé que ce produit
était conforme aux exigences d’efficacité
énergétique d’ENERGY STAR
®
.
* Produits homologués E S
®
19
AEM10*
AEM12*
Au Canada, visitez-nous au :
www.electromenagersge.ca
Assistance à
la clientèle
Conseils de dépannage
Instructions
de montage
Entretien et nettoyage
Consignes d’utilisation
Consignes
de sécurité
20
IMPORTANTES CONSIGNES DE SÉCURITÉ.
VEUILLEZ LIRE TOUTES LES CONSIGNES AVANT UTILISATION.
AVERTISSEMENT !
Pour votre sécurité, les informations contenues dans ce manuel doivent être suivies afin de minimiser
les risques d’incendie, de chocs électriques ou de blessures corporelles.
nN’utilisez cet appareil qu’aux fins prévues
décrites dans le manuel d’utilisation.
nCe climatiseur doit être correctement
installé conformément aux Instructions
d’Installation avant toute utilisation.
nNe débranchez jamais votre climatiseur en
tirant sur le cordon d’alimentation. Prenez
toujours fermement la fiche en main et tirez
pour la sortir de la prise.
nRemplacez immédiatement tout cordon
électrique usé ou endommagé. Un
cordon d’alimentation endommagé doit
être remplacé par un nouveau cordon
d’alimentation obtenu du fabricant.
Ne réparez pas le cordon endommagé.
N’utilisez pas un cordon fissuré ou
présentant des dommages dus aux
frottements soit sur sa longueur ou aux
extrémités du côté de la fiche ou du
raccord.
nSi la prise de courant est d’un format
différent de la fiche, cette prise doit être
changée par un électricien qualifié.
n Eteignez votre climatiseur et débranchez-le
avant d’effectuer des réparations ou de le
nettoyer.
REMARQUE : Nous vous recommandons de faire
effectuer la maintenance par un technicien qualifié.
n Pour votre sécurité, ne stockez pas et
n’utilisez pas de matériaux combustibles,
d’essence ou d’autres vapeurs et liquides
inflammables dans les parages de cet
appareil ou de tout autre appareil.
n Tous les climatiseurs contiennent des
fluides frigorigènes qui, conformément, à la
législation fédérale doivent être retirés avant
la mise au rebut de l’appareil. Si vous mettez
au rebus un ancien appareil contenant des
fluides frigorigènes, vérifiez la procédure à
suivre auprès de la compagnie responsable
de l’élimination.
n Ces systèmes de climatisation R410A
demandent que les contracteurs et
les techniciens utilisent des outils, de
l’équipement et des mesures de sécurité
homologués pour une utilisation avec
frigorigène. N’UTILISEZ PAS un
équipement certifié pour fluide R22
refrigerant only.
CONSIGNES DE SÉCURITÉ
Ne coupez pas ou n’enlevez pas, sous aucun prétexte,
la troisième broche de mise à la terre du cordon
d’alimentation. Pour des raisons de sécurité, cet appareil
doit être correctement mis à la terre.
N’utilisez PAS d’adaptateur avec cet appareil.
Le cordon d’alimentation de cet appareil
est équipé d’une fiche à trois broches (pour
une mise à la terre) qui s’adapte à la prise
de courant standard à 3 broches (pour une
mise à la terre) pour minimiser les risques
de chocs électriques par cet appareil.
Le cordon d’alimentation est équipé d’un
dispositif d’interruption du courant. Un
bouton d’essai et de réenclenchement est
fourni sur le boîtier de la prise. Vous devez
tester le mécanisme régulièrement en
appuyant d’abord sur le bouton TEST (essai)
puis sur le bouton RESET (réenclenchement)
lorsque l’appareil est branché. Si le bouton
TEST (essai) ne bascule pas ou si le bouton
RESET (réenclenchement) ne reste pas
enclenché, cessez d’utiliser votre climatiseur
et appelez un technicien de service qualifié.
Faites vérifier la prise murale et le circuit
électrique par un électricien qualifié pour
s’assurer que le système est correctement
mis à la terre.
Dans le cas d’une prise biphasée,
l’installateur a la responsabilité et l’obligation
de la remplacer par une prise triphasée
correctement mise à la terre.
Le climatiseur doit toujours être branché
à sa propre prise électrique d’une tension
nominale correspondant à celle indiquée
sur sa plaque signalétique.
Ceci permet d’obtenir un meilleur rendement
du climatiseur et évite de surcharger les
circuits électriques du domicile qui risque
d’occasionner un incendie en surchauffant.
Consultez les Consignes d’Installations, dans
la section Exigences Electriques pour les exigences
de branchements électriques particuliers.
BRANCHEMENTS ÉLECTRIQUES
Consignes
de sécurité
Consignes d’utilisation
Entretien et nettoyage
Instructions
de montage
Conseils de dépannage
Assistance à
la clientèle
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

GE AEM10AN Le manuel du propriétaire

Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues