Pepperl+Fuchs E18-LAS/EV18-LAS/25/32/76a/92 Mode d'emploi

Taper
Mode d'emploi
alle Maße in mm
DimensionsAbmessungen
Technische Daten Technical data
Elektrischer Anschluss Electrical connection Adressen/Addresses
Sicherheitshinweise:
•Vor der Inbetriebnahme Betriebsanleitung lesen
Anschluss, Montage und Einstellung nur durch Fachpersonal
Kein Sicherheitsbauteil gemäß EU-Maschinenrichtlinie
Security Instructions:
Read the operating instructions before attempting commissioning
Installation, connection and adjustments should only be undertaken by specialist personnel
Not a safety component in accordance with the EU Machinery Directive
all dimensions in mm
www.pepperl-fuchs.com
Pepperl+Fuchs GmbH
68301 Mannheim · Germany
Tel. +49 621 776-4411
Fax +49 621 776-27-4411
E-mail: fa-inf[email protected]
Worldwide Headquarters
Pepperl+Fuchs GmbH · Mannheim · Germany
E-mail: fa-inf[email protected]
USA Headquarters
Pepperl+Fuchs Inc. · Twinsburg · USA
E-mail: fa-inf[email protected]
Asia Pacific Headquarters
Pepperl+Fuchs Pte Ltd · Singapore
E-mail: fa-inf[email protected]
Company Registration No. 199003130E
1
2
4
3
X
24 24
Sender Empfänger
Lichtaustritts-
fläche ø1mm zentrisch
Eintrittsfläche
Sechskantmutter
Anzeige-LED Typenschild
Ansicht X
28
80 ±0.3
M12 x 1
ø12
M18 x 1
65 ±0.3
ø16.5
31±0.3
21
4
4
Einweg-Lichtschranke
mit Gerätestecker M12 x 1, 4-polig
Thru-beam sensor
with 4-pin, M12 x 1 connector
E18-LAS/EV18-LAS/25/32/76a/92
Einzelkomponenten
Sender E18-LAS/92
Empfänger EV18-LAS/32/92
Allgemeine Daten
Betriebsreichweite 0 ... 10 m
Grenzreichweite 18 m
Lichtsender Laserdiode
Lichtart rot, Wechsellicht
Laserkenndaten
Hinweis LASERLICHT , NICHT IN DEN STRAHL BLICKEN
Laserklasse 1
Wellenlänge 650 nm
Strahldivergenz 1 mrad
Impulsdauer 15 µs
Wiederholrate 10 kHz
max. Puls Energie < 10,2 nJ
Hindernisgröße 1,2 mm
Lichtempfänger Fotodiode
Lichtfleckdurchmesser ca. 2 mm bei Reichweite 1,5 m
Öffnungswinkel Empfänger +/-2°
Lichtaustritt frontal
Fremdlichtgrenze
Gleichlicht 5000 Lux
Hysterese H 25 %
Kenndaten funktionale Sicherheit
MTTFd 208,3 a
Gebrauchsdauer (TM) 7 a
Diagnosedeckungsgrad (DC) 60 %
Anzeigen/Bedienelemente
Funktionsanzeige LED gelb, leuchtet bei freiem Lichtstrahl, blinkt bei Unterschreiten der Funktionsres-
erve
Elektrische Daten
Betriebsspannung UB10 ... 30 V DC
Welligkeit 10 %
Leerlaufstrom I0Sender 25 mA , Empfänger 60 mA
Eingang
Testeingang Senderabschaltung
Sender ein: 0 ... +3V
Sender aus: +5V ... +UB
Ausgang
Vorausfallausgang PNP, offener Kollektor , kurzschlussfest
inaktiv: Signalpegel > ca. 30 % des Pegels bei sauberer Optik
aktiv: Signalpegel < ca. 30 % des Pegels bei sauberer Optik
Schaltungsart hellschaltend
Signalausgang 1 PNP, kurzschlussfest, offener Kollektor
Schaltspannung max. 30 V DC
Schaltstrom max. 100 mA
Schaltfrequenz f 1000 Hz
Ansprechzeit 0,5 ms
Umgebungsbedingungen
Umgebungstemperatur 0 ... 50 °C (32 ... 122 °F)
Lagertemperatur -40 ... 85 °C (-40 ... 185 °F)
Mechanische Daten
Schutzart IP65
Anschluss Gerätestecker M12 x 1, 4-polig
Material
Gehäuse Messing, vernickelt
Lichtaustritt Glas
Stecker Metall
Masse je 45 g
Normen- und Richtlinienkonformität
Richtlinienkonformität
EMV-Richtlinie 2004/108/EG EN 60947-5-2:2007
Normenkonformität
Produktnorm EN 60947-5-2:2007
IEC 60947-5-2:2007
Schock- und Stoßfestigkeit IEC / EN 60068, Halb-Sinus, 30 g je X, Y und Z Richtung
Vibrationsfestigkeit IEC / EN 60068-2-6, Sinus, 10 - 150 Hz, 5 g je X, Y und Z Richtung
Laserklasse IEC 60825-1:2007
EN 60825-1:2007
Zulassungen und Zertifikate
1
2
4
3
X
24 24
Emitter Receiver
Light outlet surface
ø1 mm, centric
Entry surface
Hexagonal nut
Display LED Name plate
View X
28
80 ±0.3
M12 x 1
ø12
M18 x 1
65 ±0.3
ø16.5
31±0.3
21
4
4
10/17/2018
Date:
Option:
2
1
3
4
0 V
+UB
Q
I/O
Alarm
/32/76a /76a
Te s t
1
3
4
2
System components
Emitter E18-LAS/92
Receiver EV18-LAS/32/92
General specifications
Effective detection range 0 ... 10 m
Threshold detection range 18 m
Light source laser diode
Light type modulated visible red light
Laser nominal ratings
Note LASER LIGHT , DO NOT STARE INTO BEAM
Laser class 1
Wave length 650 nm
Beam divergence 1 mrad
Pulse length 15 µs
Repetition rate 10 kHz
max. pulse energy < 10.2 nJ
Target size 1.2 mm
Light receiver photo diode
Diameter of the light spot approx. 2 mm at detection range 1.5 m
Angle of divergence Receiver +/-2°
Optical face frontal
Ambient light limit
Continuous light 5000 Lux
Hysteresis H 25 %
Functional safety related parameters
MTTFd 208.3 a
Mission Time (TM) 7 a
Diagnostic Coverage (DC) 60 %
Indicators/operating means
Function indicator LED yellow, lights up when light beam is free, flashes when falling short of the stability
control
Electrical specifications
Operating voltage UB10 ... 30 V DC
Ripple 10 %
No-load supply current I0emitter 25 mA , receiver 60 mA
Input
Test input Emitter deactivation
emitter on: 0 ... +3V
emitter off: +5V ... +UB
Output
Pre-fault indication output PNP, open collector , short-circuit protected
inactive: signal strength > approx. 30 % of the strength with clean optic
active: signal strength < approx. 30 % of the strength with clean optic
Switching type light on
Signal output 1 PNP, short-circuit protected, open collector
Switching voltage max. 30 V DC
Switching current max. 100 mA
Switching frequency f 1000 Hz
Response time 0.5 ms
Ambient conditions
Ambient temperature 0 ... 50 °C (32 ... 122 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protection IP65
Connection 4-pin, M12 x 1 connector
Material
Housing brass, nickel-plated
Optical face glass
Connector metal
Mass Per 45 g
Compliance with standards and direc-
tives
Directive conformity
EMC Directive 2004/108/EC EN 60947-5-2:2007
Standard conformity
Product standard EN 60947-5-2:2007
IEC 60947-5-2:2007
Shock and impact resistance IEC / EN 60068, half-sine, 30 g in X, Y and Z direction
Vibration resistance IEC / EN 60068-2-6. Sinus. 10 -150 Hz, 5 g in each X, Y and Z directions
Laser class IEC 60825-1:2007
EN 60825-1:2007
= Hellschaltung
= Dunkelschaltung
= Light on
= Dark on
Option:
2
1
3
4
0 V
+UB
Q
I/O
Alarm
/32/76a /76a
Te s t
DIN A3 -> A7
Part. 115526 45-1119J
Doc.
Die Bestrahlung kann zu Irritationen gerade bei dunkler Umgebung führen. Nicht auf Menschen richten!
Wartung und Reparaturen nur von autorisiertem Servicepersonal durchführen lassen!
Das Gerät ist so anzubringen, dass die Warnhinweise deutlich sichtbar und lesbar sind.
Der Warnhinweis liegt dem Gerät bei und ist in unmittelbarer Nähe zum Gerät gut sichtbar anzubringen.
Vorsicht: Wenn andere als die hier angegebenen Bedienungs- oder Justiereinrichtungen benutzt oder
andere Verfahrensweisen ausgeführt werden, kann dies zu gefährlicher Strahlungseinwirkung führen.
The irradiation can lead to irritation especially in a dark environment. Do not point at people!
Maintenance and repairs should only be carried out by authorized service personnel!
Attach the device so that the warning is clearly visible and readable.
The warning accompanies the device and should be attached in immediate proximity to the device.
Caution – Use of controls or adjustments or performance of procedures other than those specified her-
ein may result in hazardous radiation exposure.
L’irradiation peut entraîner des irritations dans un environnement sombre. Ne pas orienter vers les per-
sonnes !
L’entretien et les réparations doivent être réalisés exclusivement par le personnel de service autorisé !
L’appareil doit être installé de manière à ce que les mises en garde soient clairement visibles et lisibles.
Les instructions de mise en garde sont jointes à l’appareil et doivent être installées à proximité directe
de l'appareil de manière visible.
Attention : Si d’autres dispositifs de commande ou de réglage sont utilisés que ceux indiqués ici, ou si
d’autres procédures sont exécutées, cela peut entraîner un effet préjudiciable du rayonnement.
LASERLICHT
LASER LIGHT
LASER KLASSE 1
CLASS 1 LASER PRODUCT
LASER Warnhinweise nach IEC 60825-1:2007, 21CFR 1040.10 und 1040.11 (except for
deviations pursuant to Laser Notice No. 50, dated 6-24-07) konnten nicht am Gerät befestigt
werden. Die Warnhinweise sind selbstklebend und liegen der Verpackung bei.
LASER hazard warning labels required by IEC 60825-1:2007, 21CFR 1040.10 and 1040.11
(except for deviations pursuant to Laser Notice No. 50, dated 6-24-07) could not be affixed
to the product, but are supplied with the product as self-adhesive labels in the product
packaging.
Laserhinweis Laserklasse 1
Laser notice laser class 1
Consigne laser classe 1
LASER Warnhinweise / LASER hazard warning labels
X [m]
Y [mm]
X
Y
0
5
7.5
10
0510 15
2.5
20
Charakteristische Ansprechkurve
Courbe de response caractéristique
Curve di risposta caratteristica
Characteristic response curve
Curva de respuesta característica
Möglicher Abstand (Versatz) zwischen
optischer Achse und Referenzobjekt.
Permissible distance (offset) between
optical axis and reference target.
Ecart possible entre l'axe optique et la
cible de référence.
Desplazamiento entre el eje óptico y
objeto de referencia.
Distanza possibile (sfalsato) tra l'asse
ottico e l'ogetto di riferimento.
Valid for e. g. squint angle 0°.
Gilt exemplarisch für Schielwinkel 0°.
Funktionsreserve, Stability control, Réserve de fonctionnement,
Reserva de función, Funzione riserva
x
0 5 10 15 20
1
10
100
Relative Empfangslichtstärke
Intensité relative de la lumière reçue
Intensità relativa luce in ricezione
Relative received light strength
Potencia relativa de recepción lumínica
X [m]
  • Page 1 1
  • Page 2 2

Pepperl+Fuchs E18-LAS/EV18-LAS/25/32/76a/92 Mode d'emploi

Taper
Mode d'emploi