This is the service manual for the Dantherm HCC 2 residential ventilation unit. Part number of
this service manual is 052322 and covers units with serial numbers from 1402281329260
This manual is for both installers and users of the product.
Installation and repair of the unit is to be carried out by qualied personnel only. It is the
responsibility of the installer to read and understand this service manual prior to initial start
and setup of the HCC 2 unit. Warranty is restricted to units, installed by trained personnel
only.
This application is not intended for use by persons (including children) with reduced physi-
cal, sensory or mental capabilities, unless they have been given supervision or instructions
concerning the use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Apart from the replacement of air lters and exterior cleaning of the system, any kind of
maintenance will require the use of trained personnel.
The unit MUST be earthed, through cables WITH earth wire and earthed power supply.
Copying of this service manual, or part of it, is forbidden without prior written permission
from Dantherm
Dantherm reserves the right to make changes and improvements to the product and the
service manual at any time without prior notice or obligation.
This units is designed for long term durability. When total lifetime ends, the unit should be
recycled according to national rules and with high environmental protection considerations
This manual uses following shortages for ventilation terminologies.
Short Description
T1 Outside air coming into the unit
T2 Supply air from the unit to the home
T3 Extract air from the home to the unit
T4 Exhaust air from the unit
S1 Temperature sensor no 1
S2 Temperature sensor no 2
S3 Temperature sensor no 3
S4 Temperature sensor no 4
Mode A Indicating operation mode A. See more at page 15
Mode B Indicating operation mode B.(reverse fan) See more at page 15
G4 Standard air lter class
F7 Filter class, better and absorbs ner grains than G4 lter
BP Bypass damper
IP Unique address for the Ethernet port.
DHCP Automatic settings of an Ethernet address provided from an external network
component ( if connecting the unit to Ethernet)
PC Personel computer running MS Windows
USB Universal serial bus connection– located on almost any computer
LAN Local area network is the internal network with or without wireless access
VOC Volatile organic compounds sensor, controls the ventilation level depending on
the pollution of the air.
PC Tool Windows software application specic for this unit.