Sollae Systems SIG-5441 Manuel utilisateur

Taper
Manuel utilisateur
Sollae Systems
https://www.ezTCP.com
4-Port Digital Input I/O Gateway
SIG-5441 User Manual
Version 1.2
SIG-5441 User Manual Ver. 1.2
- 1 -
https://www.ezTCP.com
This symbol, found on your product or on its packaging, indicates that
this product should not be treated as household waste when you wish to
dispose of it. Instead, it should be handed over to an applicable collection
point for the recycling of electrical and electronic equipment. By ensuring
this product is disposed of correctly, you will help prevent potential negative
consequences to the environment and human health, which could otherwise be caused by
inappropriate disposal of this product. The recycling of materials will help to conserve
natural resources. For more detailed information about the recycling of this product,
please contact your local city office, household waste disposal service or the retail
store where you purchased this product.
Note:
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
SIG-5441 User Manual Ver. 1.2
- 2 -
https://www.ezTCP.com
Contents
1 Overview ....................................................... - 4 -
1.1 Introduction ........................................................ - 4 -
1.2 Features ............................................................ - 4 -
1.3 Specification ....................................................... - 5 -
1.4 Interface ........................................................... - 6 -
1.4.1 Power .................................................................. - 6 -
1.4.2 Ethernet ............................................................... - 7 -
1.4.3 Digital Input Port ..................................................... - 7 -
1.4.4 LED ................................................................... - 11 -
1.4.5 Function Button ....................................................... - 12 -
1.4.6 Setup Port ............................................................ - 12 -
2 Preparation ................................................... - 13 -
2.1 Installing the Setting Tool ........................................ - 13 -
2.2 Connecting a Product ............................................... - 13 -
2.3 Searching Devices .................................................. - 13 -
2.4 Logging in ......................................................... - 13 -
3 Settings ...................................................... - 14 -
3.1 Network ............................................................ - 14 -
3.1.1 Obtain an IP address automatically ..................................... - 14 -
3.1.2 Use a Static IP address................................................ - 15 -
3.2 General ............................................................ - 16 -
3.2.1 Comments .............................................................. - 16 -
3.2.2 Digital Input ......................................................... - 17 -
3.3 Security ........................................................... - 18 -
3.3.1 Password .............................................................. - 18 -
3.3.2 Certificate ........................................................... - 18 -
3.3.3 spFinder .............................................................. - 18 -
3.3.4 Client ID ............................................................. - 19 -
4 Management .................................................... - 20 -
4.1 Checking Status .................................................... - 20 -
4.1.1 Product Information ................................................... - 20 -
4.1.2 Communication Status .................................................. - 21 -
4.1.3 Timeout ............................................................... - 22 -
4.1.4 Copy status ........................................................... - 22 -
4.2 Firmware Change .................................................... - 23 -
4.2.1 Online Upgrade ........................................................ - 23 -
4.2.2 Manual Upgrade ........................................................ - 24 -
4.2.3 Remote Upgrade via cloud............................................... - 24 -
4.3 Console ............................................................ - 25 -
SIG-5441 User Manual Ver. 1.2
- 3 -
https://www.ezTCP.com
4.3.1 Output Tab ............................................................ - 25 -
4.3.2 FW Log Tab ............................................................ - 26 -
4.3.3 Timeout ............................................................... - 26 -
4.4 Export/Import Setting Values ....................................... - 27 -
4.5 Factory Reset ...................................................... - 28 -
5 Technical Support and Warranty ................................ - 29 -
5.1 Technical Support .................................................. - 29 -
5.2 Warranty ........................................................... - 29 -
5.2.1 Free Repair Services .................................................. - 29 -
5.2.2 Charged Repair Services................................................ - 29 -
6 Precaution and Exemption from Liability ....................... - 30 -
6.1 Precaution ......................................................... - 30 -
6.2 Exemption from Liability ........................................... - 31 -
6.2.1 English version ....................................................... - 31 -
6.2.2 French version ........................................................ - 32 -
7 Revision History .............................................. - 34 -
SIG-5441 User Manual Ver. 1.2
- 4 -
https://www.ezTCP.com
1 Overview
1.1 Introduction
SIG-5441 is an industrial I/O Gateway connected to Sollae Cloud. It is equipped
with 4 digital input ports and an Ethernet interface. Users can remotely monitor
digital values of sensors/devices connected to this product by using a web browser
on your PC, tablet or smartphone.
This document presents the information related to device only. To connect the
device to Sollae Cloud, see Sollae Cloud User Guide.
1.2 Features
4 digital input ports: Wet Contact, Dry Contact, NPN, PNP input
Digital input port with Up/Down Counter
Ethernet Interface
Freely connected to Sollae Cloud via MQTT
Data is encrypted and securely transmit using TLS 1.2
Client certificate authentication for devices
Industrial temperature range (-40℃ ~ +85℃)
SIG-5441 User Manual Ver. 1.2
- 5 -
https://www.ezTCP.com
1.3 Specification
Digital Input
Dry Contact / Wet Contact / NPN / PNP
4.5V ~ 25V
4 ports
Network Physical Interface
10Base-T/100Base-TX Ethernet (RJ45)
Ethernet Speed Auto Sense
1:1 or Cross-over Cable Auto Sense
Software Functions
IP, TCP, ICMP, DHCP, mDNS, MQTT, SSL/TLS 1.2
Client certificate-based mutual authentication over TLS
1.2
Indicators
MTX, MRX, Di0, Di1, Di2, Di3
Management
Configuration and Monitoring Tool
Password
Dimension
94mm x 57mm x 23mm
about 65g
Operating Environment
DC5V±0.5V
Reverse Voltage Protection / Surge Protection
typically, 150mA
-40℃ ~ +85
-40℃ ~ +85
Certificate
Registration (KN 32, KN 35)
EMC 2014/30/EU, RoHS 2011/65/EU
FCC Part 15 Subpart B, Class A
Table 1-1 Specification
SIG-5441 User Manual Ver. 1.2
- 6 -
https://www.ezTCP.com
1.4 Interface
Figure 1-1 Interface
1.4.1 Power
SIG-5441 requires DC5V power supply whose specification is as follows:
Figure 1-2 Power
SIG-5441 User Manual Ver. 1.2
- 7 -
https://www.ezTCP.com
1.4.2 Ethernet
SIG-5441 provides 10/100Mbps Ethernet. The pin assignment is as follows:
Figure 1-3 Ethernet
1.4.3 Digital Input Port
This port is interfaced with a 3.5mm pitch 6-pole terminal block.
Figure 1-4 Digital Input Port
Port Specification
Division
Value
Number of ports
4
Maximum Input Voltage
DC 25V
Voltage Required for HIGH decision
higher than DC 4.5V
Voltage for LOW decision
lower than DC 1V
Table 1-2 Port Specification
SIG-5441 User Manual Ver. 1.2
- 8 -
https://www.ezTCP.com
Circuit Diagram of Digital Input
Figure 1-5 Circuit Diagram of Digital Input
WET contact
Figure 1-6 WET contact
SIG-5441 User Manual Ver. 1.2
- 9 -
https://www.ezTCP.com
DRY contact
Figure 1-7 DRY contact
NPN transistor
Figure 1-8 NPN transistor
SIG-5441 User Manual Ver. 1.2
- 10 -
https://www.ezTCP.com
PNP transistor
Figure 1-9 PNP transistor
SIG-5441 User Manual Ver. 1.2
- 11 -
https://www.ezTCP.com
1.4.4 LED
SIG-5441 provides 8 LEDs.
Figure 1-10 4 LED
LED operations according to each state are as follows:
When the script is running: RUN
When the script is running: RUN
When a network is not connected: LINK
When a network is connected: LINK
When a MQTT connection is NOT established: MTX & MRX
When sending data to the cloud: MTX
When receiving data (command) from cloud: MRX
When the input port is LOW: Di0, Di1, Di2 & Di3
When the input port is HIGH: Di0, Di1, Di2 & Di3
SIG-5441 User Manual Ver. 1.2
- 12 -
https://www.ezTCP.com
1.4.5 Function Button
This button is used to implement a factory reset.
1.4.6 Setup Port
This port is used for making a connection with a PC via USB cable.
SIG-5441 User Manual Ver. 1.2
- 13 -
https://www.ezTCP.com
2 Preparation
2.1 Installing the Setting Tool
You need a Windows program which is called spFinder to use this product. Download
the program on our web site and install it on your PC.
Functions of the spFinder are as follows:
Searching products connected via network and USB
Setting products
Monitoring status of products
2.2 Connecting a Product
Connect a product with your PC via a LAN cable or a USB cable. In the case of
using a LAN cable, note that your PC and the product should be on the same local
area network.
2.3 Searching Devices
Run spFinder on your PC and press the search button. If you select the product
found, the setup menu appears on the right.
2.4 Logging in
Before accessing the searched product, you need to log in first. The default ID
and password are as follows:
Division
Default Values
ID
sig-5441
Password
sig-5441
Table 2-1 The default values of ID and password
If you search the product via network and it has the default value for a password,
spFinder automatically processes the login.
SIG-5441 User Manual Ver. 1.2
- 14 -
https://www.ezTCP.com
3 Settings
3.1 Network
3.1.1 Obtain an IP address automatically
This product can automatically obtain an IP address by DHCP. A DHCP server is
required to use this.
Figure 3-1 Obtain an IP address automatically
Select the [Obtain an IP address automatically].
Check the [Obtain DNS server address automatically] and click the [Save]
button.
SIG-5441 User Manual Ver. 1.2
- 15 -
https://www.ezTCP.com
3.1.2 Use a Static IP address
You can set a static IP address to this product.
Figure 3-2 Use a static IP address
Select the [Use static IP address].
Set the [Local IP address], [Subnet mask], [Gateway IP address] and [DNS IP
address].
Click the [Save] button.
SIG-5441 User Manual Ver. 1.2
- 16 -
https://www.ezTCP.com
3.2 General
Figure 3-3 General
3.2.1 Comments
This setting is for storing the product description. The maximum setting size of
this item is 32 bytes. We can add information such as: When a device is registered
to the cloud, this field will be used as the default device description on Sollae
Cloud.
SIG-5441 User Manual Ver. 1.2
- 17 -
https://www.ezTCP.com
3.2.2 Digital Input
Valid Time (Unit: ms)
This item is to set the valid time of input signal. In order for the input
signal to be judged as a valid signal, it must last longer than the time set
in this item. The setting unit is milliseconds; The range is 100 to 30000. The
default value is 100.
Counter Type
This item is to set the counter type of each port. You can choose one among
three options: Rise (rising edge), Fall (falling edge) and Both (rising edge
or falling edge). The default value is Rise.
Counter Direction
This item is to set the counter direction: Up (counting up) or Down
(counting down). The default value is Up
Default Count Value
The value that counter will start after the device booting up.
Valid Time, Counter Type, Counter Direction, and Default Count Value can also be
set via Sollae Cloud after the device is registered under an account.
User Interface and other features configurations can only be set via Sollae Cloud.
SIG-5441 User Manual Ver. 1.2
- 18 -
https://www.ezTCP.com
3.3 Security
Figure 3-4 Security
3.3.1 Password
Both ID and password are required to access this product. Note that changing the
default password to another is highly recommended for security. The password should
be longer than 8 characters.
Input a password to use to [Password] and [Retype password].
Click the [Save] button.
3.3.2 Certificate
All TLS certificates were preloaded to the device, please ignore this part.
3.3.3 spFinder
These items are related to spFinder use.
Local search
If this item is not checked, you will not be able to search for or connect to
the product on your local network. This item can be set only when the product
is connected via USB.
Network connection
If this item is not checked, the product cannot be searched on the local
network and the product cannot be connected on the local or remote network.
This item can be set only when the product is connected via USB.
SIG-5441 User Manual Ver. 1.2
- 19 -
https://www.ezTCP.com
Remote access
If this item is checked, the product can be connected from the remote network.
For security, this item is unchecked by default.
3.3.4 Client ID
The Unique ID which is used to register the device under your account in Sollae
Cloud. See more detail on Sollae Cloud.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

Sollae Systems SIG-5441 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues