Pentair H SERIES Water Filtration Systems Manuel utilisateur

Catégorie
Filtres à eau
Taper
Manuel utilisateur
H SERIES WATER FILTRATION SYSTEMS
SISTEMA DE FILTRACIÓN DE AGUA DE LA SERIE H
H SÉRIE SYSTÈME DE FILTRAGE D’EAU
INSTALLATION AND OPERATION MANUAL
MANUAL DE INSTALACIÓN Y OPERACIÓN
MANUEL D'INSTALLATION ET D'UTILISATION
EVERPURE
2 EVERPURE H-Series Water Filtration Systems
INSTALLATION INSTRUCTIONS - ENGLISH
Product Specications .......................................... Page 3
Tools Required ....................................................... Page 4
Basic Installation Instructions ................................ Page 4
H-1200 Installation Instructions .........................Pages 6-7
Claims & Notes ........................................................Page 7
INSTRUCCIONES DE INSTALACIÓN - ESPAÑOL
Especicaciones Del Producto .......................... Página 14
Herramientas necesarias ................................... Página 15
Instrucciones básicas de instalación.................. Página 15
H 1200 Instrucciones de instalación ............. Páginas 17-18
Declaraciones y notas ........................................ Página 18
INSTRUCTIONS D’INSTALLATION - FRANÇAIS
Caractéristiques Techniques Du Produit .............. Page 25
Outils nécessaires ................................................ Page 26
Instructions d’installation de base ........................ Page 26
Consignes d’utilisation pour l’H 1200 .............. Pages 28-29
Revendication & remarques ................................. Page 29
ENGLISH
EVERPURE H-Series Water Filtration Systems 3
The Universal Plumbing Code adopted by over 20
states, and other specic state and county codes, prohibit the
use of saddle valves and their use is never recommended. You
must adhere to your state/local plumbing codes. Consult your
licensed plumber if you have related questions.
Do NOT use copper tubing with the John Guest
Fittings provided with your Everpure Filter System. Copper tubing
may appear to t, but water leaks will develop over time and use.
If copper tubing is required, you must use copper compression
ttings available from any hardware/plumbing supply.
THE OWNER’S GUIDE IS APPLICABLE FOR THE FOL-
LOWING
EVERPURE FILTER MODELS:
Multiple Appliance Connections: You can also connect your
Everpure Filter to the refrigerator for ice and water, an instant hot
water dispenser or chiller, or a plumbed-in coffee brewer. Simply
install connection “tees” (available from any hardware/plumbing
supply) in the water line between the lter and the faucet adaptor,
and run new tubing to each appliance.
NOTE:
Spent adsorption media will not be regenerated and used.
NOTE:
If adsorption media is affected by chlorine, water supply
should be treated to remove chlorine prior to entering lter.
NOTE:
DO NOT connect this system to a commercial ice maker.
These appliances require ow and volume beyond the design
limits of your undersink lter system.
NOTE:
If connecting to a home ice maker and there is no lter
faucet connection under the sink, a ush valve is required.
Thank you for purchasing an Everpure§ commercial-grade
water ltration system for your home. With your Everpure
system, you get premium quality water direct from your tap
that’s great-tasting and convenient for you and your family.
Product Specications:
•For Cold Water Use Only
•Temperature Range: 35-100°F (2-38°C)
•Min.-Max. Working Pressure:
10-125 psi (0.7-8.6 bar)
•Service Flow Rate: 0.5 gpm (1.9 Lpm)
Model H-54 Rated Capacity: 750 gal (2,839 L)
Model H-300 Rated Capacity: 300 gal (1,136 L)
Model H-104 Rated Capacity: 1,000 gal (3,785 L)
Model H-300-HSD Rated Capacity: 300 gal (1,136 L)
Model H-300-NXT Rated Capacity: 300 gal (1,136 L)
Model H-1200 Rated Capacity: 1,000 gal (3,785 L)
For optimum performance, cartridge replacement is
required once a year, or sooner if ow becomes too
slow for convenience, or if the unit’s rated capacity is
reached.
For purchase of replaceable components, please contact your local distributor.
H-1200 customers: Instructions for installing the H-1200
begin on page 6 of this Installation and Operation Guide.
ENGLISH
4EVERPURE H-Series Water Filtration Systems
BASIC INSTALLATION INSTRUCTIONS
Tools Needed For Installation
#2 Phillips Screwdriver • Wrench • Pencil
• Utility Knife • Measuring Tape
1. OPEN CARTON & INSPECT PARTS
Installation Parts
Key Description Part No.
1 QL3 Filter Head
(incl. Qty. 2 ea of 3 & 4)
EV925831
2Filter Cartridge (incl. 10 )
– Model H-54 EV925268
– Model H-300 EV927072
– Model H-104 EV961211
– Model H-300-HSD EV927075
– Model H-300-NXT EV927441
3 Locking Washers
(2 req.)
EV306204
4 Screws
(2 req.)
EV306196
5 Angle Stop Valve Adaptor EV312120
6 Tubing, 1/4" poly
(per foot)
A0860119
7
Elbow Fitting Pack Restrictor
(incl. Qty. 2 ea of 3 & 4)
EV308168
8 Plumbers Tape EV312119
9 Faucet Connector EV312135
10 Everpure Filter Timer EV314160
2. VERIFY UNDERSINK MOUNTING LOCATION
Measure 22" from the base of the cabinet, and mark the
mounting location for the top of the lter head. Make sure
there is adequate space above the head to open and close
the built-in shut off valve and to avoid crimping the water
line tubing. Also, make sure your chosen location offers easy
access for future cartridge changes.
1
1
2
3
5
6
7
8
9
10
4
2
22"
ENGLISH
EVERPURE H-Series Water Filtration Systems 5
DIMENSION Width Height Depth
H-54 5" 15" 5"
H-104 5" 20" 5"
H-300 5" 22" 5"
H-300-HSD 5" 22" 5"
H-300-NXT 5" 22" 5"
NOTE:
The head and cartridge must be mounted in the
vertical position, with the cartridge hanging down.
3. MOUNT FILTER HEAD UNDER SINK
A. Identify Filter Head and the two Elbow Fittings, and
note that the Outlet Fitting has a black band. This
tting includes a small restrictor insert to ensure
maximum ow at 0.5 gpm (1.9 Lpm) per minute.
B. Apply Plumbers Tape to the threads of each Elbow
Fitting. Wrap tape in direction of the threads to
ensure a tight t and avoid small leaks.
C. Screw Inlet Elbow Fitting into the left side of the lter
head, and hand tighten only.
D. Screw Outlet Elbow Fitting (black band) into the right
side of the lter head in the same manner.
E. Securely mount the lter head on the cabinet wall
using the enclosed mounting screws and washers.
4. ATTACH INLET WATER SUPPLY
F. Locate and close the cold water Angle Stop Valve
under your kitchen sink. Open cold water line of faucet
to release water pressure.
G. Unscrew and disconnect the braided tubing on top of
the Angle Stop Valve.
H. Attach the bottom of Angle Stop Adaptor to the
existing cold water Angle Stop Valve.
I. Attach the braided tubing to the top of the Angle Stop
Adaptor.
J. Close side valve on Angle Stop Adaptor and open cold
water Angle Stop Valve to return water service to
kitchen sink. Check for leaks.
NOTE:
Plumbers Tape should not be required for
these next steps.
K. Measure length of tubing needed to connect Angle
Stop Adaptor to Inlet Elbow Fitting on Filter Head.
Allow adequate tubing to avoid sharp turns.
L. Cut tubing at a 90° angle using a sharp knife.
M. Insert ends of tubing into quick-connect ttings. Push
tube into tting and gently pull to conrm a tight t.
5. ATTACH FILTERED WATER TO SINK FAUCET
N. Install separate faucet for ltered drinking water.
Follow individual manufacturers instructions.
O. Attach Faucet Connector Fitting to bottom end of
threads on new faucet assembly. Plumbers Tape
should not be required for this step.
P. Measure length of tubing needed to connect the
Outlet Elbow Fitting on Filter Head to the new Faucet
Connector Fitting. Allow adequate tubing to avoid
sharp turns. Cut and insert each end of the tubing into
the ttings.
3BCD
E
GH
I
LM
4
F
P
O
N
5
ENGLISH
6EVERPURE H-Series Water Filtration Systems
1
1
2
35
6
78
9
10 11
12
4
Q
R
S
T
Label
Lug
U
X
6
V W
Y
6. INSTALL AND FLUSH FILTER CARTRIDGE
Q. Lift handle of the built-in shut off Valve on the Head.
R. Hold Head rmly with one hand.
S. Align cartridge lug with label on lter Head.
T. Insert lter Cartridge – Push upwards.
U. Turn it to the right – About 1⁄4 turn – Until rotation
stops.
V. Open Side Valve of Angle Stop Adaptor and check for
leaks up to Inlet Elbow Fitting.
W. Open Filtered Water Faucet.
X. Lower handle of built-in shut off valve on the Head,
to ush water to the sink.
NOTE:
Flush new lter cartridges for at least 5
minutes to remove air and any loose carbon. At rst
the water may appear cloudy due to trapped air in
the lter and tubing. If water continues to be cloudy
for more than one week, please contact Everpure
Technical Services for assistance.
Y. Activate Filter Timer by pinching bubble until you
feel a change in resistance as the lter timer “pops.”
Within a few seconds, a thin RED line will appear in
the white window showing the Timestrip has been
activated. Peel away backing and adhere to desired
location. When the white window is completely lled
with RED, it is time to replace your product.
H-1200 INSTRUCTIONS
Tools Needed For Installation
#2 Phillips Screwdriver
Wrench
Utility Knife
Measuring Tape
Pencil
1. OPEN CARTON & INSPECT PARTS
Installation Parts
Key Description Part No.
1 Twin Filter Head N/A
2H-1200 Filter Cartridges
(Set of 2) (Includes 10 )EV928201
3 Locking Washers (2 req.) EV306204
4 Screws (2 req.) EV306196
5 Angle Stop Valve Adaptor EV312120
6 Tubing, 1/4" poly (per foot) A0860119
7
Elbow Fitting Pack Restrictor
(incl. Qty. 2 ea of #3 & #4) EV308168
8 Plumbers Tape EV312119
9 Faucet Connector EV312135
10 Everpure Filter Timer EV314160
11 Shut Off Valve,
3/8" John Guest x 3/8" FPT
EV309860
12 Coupler, 3/8" FPT Stainless EV312350
ENGLISH
EVERPURE H-Series Water Filtration Systems 7
2. VERIFY UNDERSINK MOUNTING LOCATION
Measure 22" from the base of the cabinet, and mark the
mounting location for the top of the lter head. Measure
13" for the width required for the H-1200 System with dual
cartridges. Make sure there is adequate space above the
head to open and close the shut-off valve and to avoid
crimping the water line tubing. Also, make sure your chosen
location offers easy access for future cartridge changes.
DIMENSION Width Height Depth
H-1200 13" 22" 5"
NOTE: The head and cartridge must be mounted in the
vertical position, with the cartridge hanging down.
3. MOUNT FILTER HEAD UNDER SINK
A. Identify Dual Filter Head and Shut Off Valve (EV309860).
B. Apply Plumbers Tape to the threads on the inlet (left)
side of the Head. Screw on the new Shut Off Valve
and hand tighten. Repeat for the Stainless Coupler
(EV312350) for the outlet (right) side of the Head.
C. Apply Plumbers Tape to the threads of the Outlet
Elbow Fitting (black band). Screw into the outlet of
the Stainless Coupler. Wrap tape in direction of the
threads to ensure a tight t and avoid small leaks.
D. Securely mount the lter head on the cabinet wall
using the enclosed mounting screws and washers.
4. Go to page 5 and follow Basic Installation Instructions,
Steps 4, 5, and 6, to complete the H-1200 System
installation.
CLAIMS & NOTES
This installation must comply with all applicable state and
local regulations.
Do not use with water that is microbiologically unsafe or
unknown quality without adequate disinfection before or
after the system. Systems certied for cyst reduction may be
used on waters that may contain lterable cysts.
Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, water supply
should be treated to remove chlorine prior to entering lter.
Testing was performed under standard laboratory
conditions, actual performance may vary.
EPA Est. No. 002623-IL-002
3A
D
Dual Filter Head Shut Off Valve
C
B
2
22"
The H-54, H-300, H-104, H-300-HSD, & H-1200 are
Tested and Certied by NSF International against CSA
B483.1 and NSF/ANSI 42 and 53 for the claims specied
on the Performance Data Sheet.
The H-300-NXT is Tested and Certied by NSF
International against CSA B483.1 and NSF/ANSI 42, 53
and 401 for the claims specied on the Performance
Performance Data Sheet.
C US
C US
The H-1200 is certied by IAPMO R&T against NSF/ANSI
53 for the reduction of peruorooctanoic acid (PFOA)
and peruorooctane sulfonate (PFOS).
ENGLISH
EVERPURE
H104 CARTRIDGE  PART NO. EV961211, EV961216
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a
water treatment unit, you have your water tested to determine
your actual treatment needs.
FEATURES
Finely polishes treated water to premium quality for
drinking and cooking.
Reduces chlorine taste and odor.
Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and suldes.
NSF/ANSI Standard 53 certied to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Reduces common earthy, moldy, shy tastes and odors.
Reduces lead to below the Federal Action Level.
Reduces particles as small as 0.5 micron in size by
mechanical means.
H-104 Performance Data
This system has been tested according to NSF/ANSI 42 and 53
for the reduction of the substances listed be low.
The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specied in
NSF/ANSI 42 and 53.
OPERATING SPECIFICATIONS
• Capacity: 1,000 gallons (3,780L)
• Pressure Requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
• Temperature: 35-100°F (2°-38°C)
• Flow Rate: 0.5 gpm (1.9 Lpm
PERFORMANCE DATA SHEET
H104 DRINKING WATER SYSTEMS
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
Space required: 5 x 5 x 20 in. (13 x 13 x 51 cm) including
2½ inches of clear space under unit for cartridge change.
Install vertically with cartridge hanging down.
Use minimum length of tubing possible.
Flush new cartridge at full ow for three minutes to purge air.
Replace cartridges when capacity is reached, or when flow
becomes too slow, but at least annually.
SPECIAL NOTICES
Installation instructions, parts and service availability,
and standard warranty are included with the product.
This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges. Suggested retail $122.99.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certied for cyst reduction may be used on
disinfected waters that may contain lterable cysts.
The contaminants or other substances removed or reduced by this
water treatment system are not necessarily in your water.
Check for compliance with state and local laws and regulations.
Tested under standard laboratory conditions, actual performance
may vary.
Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
ENGLISH
8EVERPURE H-Series Water Filtration Systems
H-104 Cartridge - Part No. EV9612-11, EV9612-16
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
Finely polishes treated water to premium quality for drinking and
cooking.
Reduces chlorine taste and odor.
Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and suldes.
NSF/ANSI Standard 53 certied to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Reduces common earthy, moldy, shy tastes and odors.
Reduces lead to below the Federal Action Level.
Reduces particles as small as 0.5 micron in size by mechanical
means.
ERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specied in NSF/ANSI 42 and 53.
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Eects
Chlorine 2.0 mg/L ± 10% 50% 87.8%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL 85% 98.8%
Standard 53—Health Eects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.010 mg/L 99.3% 99.3%
Lead 6.5 0.15 mg/L ± 10% 0.010 mg/L 98.7% 99.3%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
OPERATING SPECIFICATIONS
Capacity: 1,000 gallons (3,780L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2°-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
EPA Est. 002623-IL-002
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
g n i d u l c n i ) m c 1 5 x 3 1 x 3 1 ( . n i 0 2 x 5 x 5 : d e r i u q e r e c a p S
2½ inches of clear space under unit for cartridge change.
Install vertically with cartridge hanging down.
Use minimum length of tubing possible.
Flush new cartridge at full ow for three minutes to purge air.
Replace cartridges when capacity is reached, or when flow becomes
too slow, but at least annually.
SPECIAL NOTICES
dradnats dna ,ytilibaliava ecivres dna strap ,snoitcurtsni noitallatsnI
warranty are included with the product.
ot gnidrocca deniatniam eb tsum metsys retaw gniknird sihT
manufacturer’s instructions, including replacement of lter
cartridges. Suggested retail $122.99.
nwonknu fo ro efasnu yllacigoloiborcim si taht retaw htiw esu ton oD
quality without adequate disinfection before or after the system.
Systems certied for cyst reduction may be used on disinfected
waters that may contain lterable cysts.
siht yb decuder ro devomer secnatsbus rehto ro
stnanimatnoc ehT
water treatment system are not necessarily in your water.
.snoitaluger dna swal lacol dna etats htiw ecnailpmoc rof kcehC
ecnamrofrep lautca ,snoitidnoc yrotarobal dradnats rednu detseT
may vary.
Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering lter.
System Tested and Certied by NSF International against
CSA B483.1 and NSF/ANSI 42 and 53 for the claims
specied on the Performance Data Sheet.
H-104 DRINKING WATER SYSTEMS
C US
PERFORM ANC E DATA SHEET
EVERPURE
H-104 Cartridge - Part No. EV9612-11, EV9612-16
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
dna gniknird rof yt i lauq muimerp ot retaw detaert sehsi lop yleniF
cooking.
Reduces chlorine taste and odor.
, nor i dez i d i xo sa hcus se t a l uc i t rap reh t o dna t sur , t r i d secudeR
manganese, and sulfides.
NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Reduces common earthy, moldy, fishy tastes and odors.
Reduces lead to below the Federal Action Level.
Reduces particles as small as 0.5 micron in size by mechanical
means.
H-104 PERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ° 50% 87.8%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL ° 85% 98.8%
Standard 53—Health Effects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.010 mg/L 99.3% 99.3%
Lead 6.5 0.15 mg/L ± 10% 0.010 mg/L 98.7% 99.3%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
OPERATING SPECIFICATIONS
Capacity: 1,000 gallons (3,780L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2°-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
EPA Est. 002623-IL-002
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
gnidulcni )mc 15 x 31 x 31( .ni 02 x 5 x 5 :deriuqer ecapS
2½ inches of clear space under unit for cartridge change.
Install vertically with cartridge hanging down.
Use minimum length of tubing possible.
Flush new cartridge at full flow for three minutes to purge air.
semoceb wo l f nehw r o , dehcae r s i y t i capac nehw segd i r t r ac eca l peR
too slow, but at least annually.
SPECIAL NOTICES
Installation instructions, parts and service availability, and standard
warranty are included with the product.
This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges. Suggested retail $122.99.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
The contaminants or other substances removed or reduced by this
water treatment system are not necessarily in your water.
Check for compliance with state and local laws and regulations.
Tested under standard laboratory conditions, actual performance
may vary.
Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
System Tested and Certified by NSF International against
CSA B483.1 and NSF/ANSI 42 and 53 for the claims
specified on the Performance Data Sheet.
H-104 DRINKING WATER SYSTEMS
C US
PERFORMANCE DATA SHEET
System Tested and Certified by NSF International
against CSA B483.1 and NSF/ANSI 42 and 53 for the
claims specified on the Performance Data Sheet.
EPA Est. No. 002623-IL-002
8EVERPURE H-Series Water Filtration Systems
ENGLISH
EVERPURE H-Series Water Filtration Systems 9
EVERPURE
H54 CARTRIDGE  PART NO. EV973006, EV925206,
EV925266, EV925267, EV925268
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a
water treatment unit, you have your water tested to determine
your actual treatment needs.
FEATURES
Finely polishes treated water to premium quality for
drinking and cooking.
Reduces chlorine taste and odor.
Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and suldes.
NSF/ANSI Standard 53 certied to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Reduces common earthy, moldy, shy tastes and odors.
Reduces lead to below the Federal Action Level of 15 ppb.
Reduces particles as small as 0.5 micron in size by
mechanical means.
H-54 Performance Data
This system has been tested according to NSF/ANSI 42 and 53
for the reduction of the substances listed below.
The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specified
in NSF/ANSI 42 and 53.
OPERATING SPECIFICATIONS
• Capacity: 750 gallons (2,839L)
• Pressure Requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
• Temperature: 35-100°F (2°-38°C)
• Flow Rate: 0.5 gpm (1.9 Lpm
PERFORMANCE DATA SHEET
H54 DRINKING WATER SYSTEMS
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
Space required: 5 x 5 x 15 in. (13 x 13 x 38 cm) including
2½ inches of clear space under unit for cartridge change.
Install vertically with cartridge hanging down.
Use minimum length of tubing possible.
Flush new cartridge at full ow for three minutes to purge air.
Replace cartridges when capacity is reached, or when flow
becomes too slow, but at least annually.
SPECIAL NOTICES
Installation instructions, parts and service availability,
and standard warranty are included with the product.
This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges. Suggested retail $100.99.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certied for cyst reduction may be used on
disinfected waters that may contain lterable cysts.
The contaminants or other substances removed or reduced by this
water treatment system are not necessarily in your water.
Check for compliance with state and local laws and regulations.
Tested under standard laboratory conditions, actual performance
may vary.
Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
ENGLISH
EVERPURE H-Series Water Filtration Systems 9
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
Finely polishes treated water to premium quality for drinking and
cooking.
Reduces chlorine taste and odor.
Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and suldes.
NSF/ANSI Standard 53 certied to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Adsorbs common earthy, moldy, shy tastes and odors.
Reduces lead to below the Federal Action Level of 10 ppb.
Reduces particles as small as 0.5 micron in size by mechanical
means.
PERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specied in NSF/ANSI 42 and 53.
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Eects
Chlorine 2.0 mg/L ± 10% ≥ 50% 86.8%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL ≥ 85% 98.8%
Standard 53—Health Eects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.005 mg/L 98.7% 99.3%
Lead 6.5 0.15 mg/L ± 10% 0.005 mg/L 99.3% 99.3%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
OPERATING SPECIFICATIONS
Capacity: 750 gallons (2,839L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2°-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
EPA Est. 002623-IL-002
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
Space required: 5 x 5 x 15 in. (13 x 13 x 38 cm) including 2- ½ inches
of clear space under unit for cartridge change.
Install vertically with cartridge hanging down.
Use minimum length of tubing possible.
Flush new cartridge at full ow for three minutes to purge air.
Replace cartridges when capacity is reached, or when flow becomes
too slow, but at least annually.
SPECIAL NOTICES
dradnats dna ,ytilibaliava ecivres dna strap ,snoitcurtsni noitallatsnI
warranty are included with the product when shipped.
ot gnidrocca deniatniam eb tsum metsys retaw gniknird sihT
manufacturer’s instructions, including replacement of lter
cartridges. Suggested list price: $100.99.
nwonkn
u fo ro ,efasnu yllacigoloiborcim si taht retaw htiw esu ton oD
quality without adequate disinfection before or after the system.
Systems certied for cyst reduction may be used on disinfected
waters that may contain lterable cysts.
siht yb decuder ro devomer secnatsbus rehto ro stnanimatnoc ehT
water treatment system are not necessarily in your water.
Check for compliance with state and local laws and regulations.
ecnamrofrep lautca ,snoitidnoc yrotarobal dradnats rednu detseT
may vary.
Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering lter.
System Tested and Certied by NSF International
against CSA B483.1 and NSF/ANSI 42 and 53 for the
claims specied on the Performance Data Sheet.
C US
PERFORM ANC E DATA SHEET
H-54 Cartridge - Part No. EV9730-06, EV9252-68, EV9252-66, EV9252-67
EVERPURE
H-104 Cartridge - Part No. EV9612-11, EV9612-16
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
dna gniknird rof yt i lauq muimerp ot retaw detaert sehsi lop yleniF
cooking.
Reduces chlorine taste and odor.
, nor i dez i d i xo sa hcus se t a l uc i t rap reht o dna t sur , t r i d secudeR
manganese, and sulfides.
NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Reduces common earthy, moldy, fishy tastes and odors.
Reduces lead to below the Federal Action Level.
Reduces particles as small as 0.5 micron in size by mechanical
means.
H-104 PERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ° 50% 87.8%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL ° 85% 98.8%
Standard 53—Health Effects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.010 mg/L 99.3% 99.3%
Lead 6.5 0.15 mg/L ± 10% 0.010 mg/L 98.7% 99.3%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
OPERATING SPECIFICATIONS
Capacity: 1,000 gallons (3,780L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2°-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
EPA Est. 002623-IL-002
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
gnidulcni )mc 15 x 31 x 31( .ni 02 x 5 x 5 :deriuqer ecapS
2½ inches of clear space under unit for cartridge change.
Install vertically with cartridge hanging down.
Use minimum length of tubing possible.
Flush new cartridge at full flow for three minutes to purge air.
semoceb wo l f nehw r o , dehcae r s i y t i capac nehw segd i r t r ac eca l peR
too slow, but at least annually.
SPECIAL NOTICES
Installation instructions, parts and service availability, and standard
warranty are included with the product.
This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges. Suggested retail $122.99.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
The contaminants or other substances removed or reduced by this
water treatment system are not necessarily in your water.
Check for compliance with state and local laws and regulations.
Tested under standard laboratory conditions, actual performance
may vary.
Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
System Tested and Certified by NSF International against
CSA B483.1 and NSF/ANSI 42 and 53 for the claims
specified on the Performance Data Sheet.
H-104 DRINKING WATER SYSTEMS
C US
PERFORMANCE DATA SHEET
System Tested and Certified by NSF International
against CSA B483.1 and NSF/ANSI 42 and 53 for the
claims specified on the Performance Data Sheet.
EPA Est. No. 002623-IL-002
ENGLISH
10EVERPURE H-Series Water Filtration Systems
H300 CARTRIDGE  PART NO. EV927071, EV927072,
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a
water treatment unit, you have your water tested to determine
your actual treatment needs.
FEATURES
Finely polishes treated water to premium quality for
drinking and cooking.
Reduces chlorine taste and odor.
Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and suldes.
NSF/ANSI Standard 53 certied to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Controls even extreme levels of common "off" taste and odors,
including those which are earthy, moldy, and fishy.
Reduces lead to below the Federal Action Level.
Effectively reduces Volatile Organic Chemicals (VOCs),
including Trihalomethanes (THMs).
Reduces particles as small as 0.5 micron in size by
mechanical means.
H-300 Performance Data
This system has been tested according to NSF/ANSI 42 and 53
for the reduction of the substances listed below.
The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specified
in NSF/ANSI 42 and 53.
NOTE: Spent adsorption media will not be regenerated and
used. If adsorption media is affected by chlorine, water supply
should be treated to remove chlorine prior to entering filter.
PERFORMANCE DATA SHEET
H300 DRINKING WATER SYSTEMS
OPERATING SPECIFICATIONS
• Capacity: 300 gallons (1,135L)
• Pressure Requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
• Temperature: 35-100°F (2°-38°C)
• Flow Rate: 0.5 gpm (1.9 Lpm
PERFORMANCE DATA SHEET REDUCTION CLAIMS FOR
ORGANIC CHEMICALS INCLUDED BY SURROGATE TESTING
ENGLISH
10EVERPURE H-Series Water Filtration Systems
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
Finely polishes treated water to premium quality for drinking and
cooking.
Reduces chlorine taste and odor.
Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and suldes.
NSF/ANSI Standard 53 certied to reduce c ysts such as
Cryptosporidium and Giardia by mechanical means.
Controls even extreme levels of common “o” tastes and odors,
including those which are earthy, moldy and shy.
Reduces lead to be low the Federal Action L evel.
Eectively reduces Volatile Organic Chemicals ( VOCs), including
Trihalomethanes (THMs).
Reduces particles as small as 0.5 micron in size by mechanical
means.
ERFORMANCE DATA
This system has been tested according to NSF/ANS 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the sy stem was reduced
to a concentration less than or equal to the permissible limit for
water leaving the sy stem, as specied in NSF/ANS 42 and 53.
NOTE:
Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering lter.
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Eects
Chlorine 2.0 mg/L ± 10% ≥ 50% 86.8%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL ≥ 85% 98.8%
Standard 53—Health Eects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 6.5 0.15 mg/L ± 10% 0.005 mg/L 99.3% 99.3%
Lead 8.5 0.15 mg/L ± 10% 0.005 mg/L 98.7% 99.3%
Chloroform 0.300 mg/L 0.015 mg/L 95.8% 98.9%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
EPA Est. 002623-IL-002
OPERATING SPECIFICATIONS
Capacity: 300 gallons (1,135L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
Performance Data Sheet Reduction Claims
for Organic Chemicals Included by Surrogate Testing
Substance Inuent Challenge
Concentration mg/L
Maximum Permissible Product
Water Concentration mg/L
alachlor 0.050 0.001
atrazine 0.100 0.003
benzene 0.081 0.001
carbofuran 0.190 0.001
carbon tetrachloride 0.078 0.0018
chlorobenzene 0.077 0.001
chloropicrin 0.015 0.0002
2,4-D 0.110 0.0017
dibromochloropropane (DBCP) 0.052 0.00002
o-dichlorobenzene 0.080 0.001
p-dichlorobenzene 0.040 0.001
1,2-dichloroethane 0.088 0.0048
1,1-dichloroethylene 0.083 0.001
cis-1,2-dichloroethylene 0.170 0.0005
trans-1,2-dichloroethylene 0.086 0.001
1,2-dichloropropane 0.080 0.001
cis-1,3-dichloropropylene 0.079 0.001
dinoseb 0.170 0.0002
endrin 0.053 0.00059
ethylbenzene 0.088 0.001
ethylene dibromide (EDB) 0.044 0.00002
haloacetonitriles (HAN):
bromochloroacentonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
0.0072
0.0082
0.0001
0.0003
heptachlor 0.025 0.00001
heptachlor epoxide 0.0107 0.0002
hexachlorobutadiene 0.044 0.001
hexachlorocyclopentadiene 0.060 0.000002
lindane 0.055 0.00001
methoxychlor 0.050 0.0001
pentachlorophenol 0.096 0.001
simazine 0.120 0.004
styrene 0.150 0.0005
1,1,2,2-tetrachloroethane 0.081 0.001
tetrachloroethylene 0.081 0.001
toluene 0.078 0.001
2,4,5-TP(silvex) 0.270 0.0016
tribromoacetic acid 0.042 0.001
1,2,4-trichlorobenzene 0.160 0.0005
1,1,1-trichloroethane 0.084 0.0046
1,1,2-trichloroethane 0.150 0.0005
trichloroethyl ene 0.180 0.001
trihal omethanes (includes):
chloroform (surrogate
chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.300 0.015
xylenes (total) 0.070 0.001
H-300 Cartridge - Part Nos. EV9270-71, EV9270-72
H-300 DRINKING WATER SYSTEM
The H-300 is Tested and Certied by NSF
International against CSA B483.1 and NSF/ANSI 42
and 53 for the claims specied on the Performance
Data Sheet.
C US
PER FORM ANCE DATA SHEE T
EVERPURE
EVERPURE
H-104 Cartridge - Part No. EV9612-11, EV9612-16
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
dna gniknird rof yt i lauq muimerp ot retaw detaert sehsi lop yleniF
cooking.
Reduces chlorine taste and odor.
, nor i dez i d i xo sa hcus se t a l uc i t rap reht o dna t sur , t r i d secudeR
manganese, and sulfides.
NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Reduces common earthy, moldy, fishy tastes and odors.
Reduces lead to below the Federal Action Level.
Reduces particles as small as 0.5 micron in size by mechanical
means.
H-104 PERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ° 50% 87.8%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL ° 85% 98.8%
Standard 53—Health Effects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.010 mg/L 99.3% 99.3%
Lead 6.5 0.15 mg/L ± 10% 0.010 mg/L 98.7% 99.3%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
OPERATING SPECIFICATIONS
Capacity: 1,000 gallons (3,780L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2°-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
EPA Est. 002623-IL-002
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
gnidulcni )mc 15 x 31 x 31( .ni 02 x 5 x 5 :deriuqer ecapS
2½ inches of clear space under unit for cartridge change.
Install vertically with cartridge hanging down.
Use minimum length of tubing possible.
Flush new cartridge at full flow for three minutes to purge air.
semoceb wo l f nehw r o , dehcae r s i y t i capac nehw segd i r t r ac eca l peR
too slow, but at least annually.
SPECIAL NOTICES
Installation instructions, parts and service availability, and standard
warranty are included with the product.
This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges. Suggested retail $122.99.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
The contaminants or other substances removed or reduced by this
water treatment system are not necessarily in your water.
Check for compliance with state and local laws and regulations.
Tested under standard laboratory conditions, actual performance
may vary.
Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
System Tested and Certified by NSF International against
CSA B483.1 and NSF/ANSI 42 and 53 for the claims
specified on the Performance Data Sheet.
H-104 DRINKING WATER SYSTEMS
C US
PERFORMANCE DATA SHEET
The H-300 is Tested and Certified by NSF
International against CSA B483.1 and NSF/ANSI 42
and 53 for the claims specified on the Performance
Data Sheet.
EPA Est. No. 002623-IL-002
Substance Inuent Challenge
Concentration mg/L
Maximum Permissible Product
Water Concentration mg/L
alachlor 0.050 0.001
atrazine 0.100 0.003
benzene 0.081 0.001
carbofuran 0.190 0.001
carbon tetrachloride 0.078 0.0018
chlorobenzene 0.077 0.001
chloropicrin 0.015 0.0002
2,4-D 0.110 0.0017
dibromochloropropane (DBCP) 0.052 0.00002
o-dichlorobenzene 0.080 0.001
p-dichlorobenzene 0.040 0.001
1,2-dichloroethane 0.088 0.0048
1,1-dichloroethylene 0.083 0.001
cis-1,2-dichloroethylene 0.170 0.0005
trans-1,2-dichloroethylene 0.086 0.001
1,2-dichloropropane 0.080 0.001
cis-1,3-dichloropropylene 0.079 0.001
dinoseb 0.170 0.0002
endrin 0.053 0.00059
ethylbenzene 0.088 0.001
ethylene dibromide (EDB) 0.044 0.00002
haloacetonitriles (HAN):
bromochloroacentonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
0.0072
0.0082
0.0001
0.0003
heptachlor 0.025 0.00001
heptachlor epoxide 0.0107 0.0002
hexachlorobutadiene 0.044 0.001
hexachlorocyclopentadiene 0.060 0.000002
lindane 0.055 0.00001
methoxychlor 0.050 0.0001
pentachlorophenol 0.096 0.001
simazine 0.120 0.004
styrene 0.150 0.0005
1,1,2,2-tetrachloroethane 0.081 0.001
tetrachloroethylene 0.081 0.001
toluene 0.078 0.001
2,4,5-TP(silvex) 0.270 0.0016
tribromoacetic acid 0.042 0.001
1,2,4-trichlorobenzene 0.160 0.0005
1,1,1-trichloroethane 0.084 0.0046
1,1,2-trichloroethane 0.150 0.0005
trichloroethyl ene 0.180 0.001
trihal omethanes (includes):
chloroform (surrogate
chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.300 0.015
xylenes (total) 0.070 0.001
EVERPURE
ENGLISH
EVERPURE H-Series Water Filtration Systems 11
H1200 CARTRIDGE  PART NO. EV928201, EV928203,
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a
water treatment unit, you have your water tested to determine
your actual treatment needs.
FEATURES
Finely polishes treated water to premium quality for
drinking and cooking.
NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
IAPMO R&T certified against NSF/ANSI 53 for the reduction
of perfluorooctanoic acid (PFOA) and perfluorooctane
sulfonate (PFOS).
High-performance system certified to reduce up to 97.5% of
PFOA/PFOS, commonly known as "forever chemicals".
Reduces dirt, rust and other particulates sulfides (oxidized iron
and manganese As tested by Everpure).
Controls even extreme levels of common "off" taste and odors,
including those which are earthy, moldy, and fishy.
Reduces lead to below the Federal Action Level of 15 ppb.
Effectively reduces Volatile Organic Chemicals (VOCs),
including Trihalomethanes (THMs).
Effectively reduces methyl tertiary-butyl ether (MTBE).
Reduces particles as small as 0.5 micron in size by
mechanical means.
H-1200 Performance Data
This system has been tested according to NSF/ANSI 42 and 53
for the reduction of the substances listed below.
The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specified
in NSF/ANSI 42 and 53.
PERFORMANCE DATA SHEET
H1200 DRINKING WATER SYSTEMS
OPERATING SPECIFICATIONS
• Capacity: 1,000 gallons (3,785L)
• Pressure Requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
• Temperature: 35-100°F (2°-38°C)
• Flow Rate: 0.5 gpm (1.9 Lpm
PERFORMANCE DATA SHEET REDUCTION CLAIMS FOR
ORGANIC CHEMICALS INCLUDED BY SURROGATE TESTING
NOTE: Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
ENGLISH
EVERPURE H-Series Water Filtration Systems 11
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
dna gniknird rof ytilauq muimerp ot retaw detaert sehsilop yleniF
cooking.
NSF/ANSI Standard 53 certied to reduce c ysts such as
Cryptosporidium and Giardia by mechanical means.
dna nori dezidixo( sediflus setalucitrap rehto dna tsur ,trid secudeR
manganese - As tested by Everpure).
slortnoC even extreme levels of common “o” tastes and odors,
including those which are earthy, moldy, and shy.
Reduces lead to be low the Federal Action L evel of 15 ppb.
( slacimehc cinagro elitalov secuder ylevitceffE VOCs), including
trihalomethanes (THMs).
Eectively reduces methyl tertiary-butyl ether (MTBE).
Reduces particles as small as 0.5 micron in size by mechanical
means.
ERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the sy stem was
reduced to a concentration less than or equal to the permissible
limit for water leaving the sy stem, as specied in NSF/ANSI 42
and 53.
Substance
Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Eects
Chlorine 2.0 mg/L ± 10% ≥ 50% 86.8%
Chloramine 3.0 mg/L ± 10% 0.5 mg/L 98.3%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL ≥ 85% 98.8%
Standard 53—Health Eects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 6.5 0.15 mg/L ± 10% 0.005 mg/L 99.3% 99.3%
Lead 8.5 0.15 mg/L ± 10% 0.005 mg/L 98.7% 99.3%
Methyl tert-
butyl ether 0.015 mg/L ± 20% 0.005 mg/L 83.5% 91.5%
Chloroform 0.300 mg/L 0.015 mg/L 99.8% 99.8%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
EPA Est. 002623-IL-002
OPERATING SPECIFICATIONS
Capacity: 1,000 gallons (3,780L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
Performance Data Sheet Reduction Claims
for Organic Chemicals Included by Surrogate Testing
Substance Inuent Challenge
Concentration mg/L
Maximum Permissible Product
Water Concentration mg/L
alachlor 0.050 0.001
atrazine 0.100 0.003
benzene 0.081 0.001
carbofuran 0.190 0.001
carbon tetrachloride 0.078 0.0018
chlorobenzene 0.077 0.001
chloropicrin 0.015 0.0002
2,4-D 0.110 0.0017
dibromochloropropane (DBCP) 0.052 0.00002
o-dichlorobenzene 0.080 0.001
p-dichlorobenzene 0.040 0.001
1,2-dichloroethane 0.088 0.0048
1,1-dichloroethylene 0.083 0.001
cis-1,2-dichloroethylene 0.170 0.0005
trans-1,2-dichloroethylene 0.086 0.001
1,2-dichloropropane 0.080 0.001
cis-1,3-dichloropropylene 0.079 0.001
dinoseb 0.170 0.0002
endrin 0.053 0.00059
ethylbenzene 0.088 0.001
ethylene dibromide (EDB) 0.044 0.00002
haloacetonitriles (HAN):
bromochloroacentonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
0.0072
0.0082
0.0001
0.0003
heptachlor 0.080 0.0004
heptachlor epoxide 0.0107 0.0002
hexachlorobutadiene 0.044 0.001
hexachlorocyclopentadiene 0.060 0.000002
lindane 0.055 0.00001
methoxychlor 0.050 0.0001
pentachlorophenol 0.096 0.001
simazine 0.120 0.004
styrene 0.150 0.0005
1,1,2,2-tetrachloroethane 0.081 0.001
tetrachloroethylene 0.081 0.001
toluene 0.078 0.001
2,4,5-TP(silvex) 0.270 0.0016
tribromoacetic acid 0.042 0.001
1,2,4-trichlorobenzene 0.160 0.0005
1,1,1-trichloroethane 0.084 0.0046
1,1,2-trichloroethane 0.150 0.0005
trichloroethylene 0.180 0.001
trihalomethanes (includes):
chlor oform (surrogate
chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.300 0.015
xylenes (total) 0.070 0.001
H-1200 Cartridge - Part Nos. EV9282-01, EV9282-03
H-1200 DRINKING WATER SYSTEM
The H-1200 is Tested and Certied by NSF
International against CSA B483.1 and NSF/ANSI 42
and 53 for the claims specified on the Performance
Data Sheet.
C US
PER FORM ANCE DATA SHEE T
NOTE:
Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering lter.
PFOA/PFOS 0.0015 mg/L ± 10% 0.00007 mg/L 95.76% 97.57%
EVERPURE
EVERPURE
ENGLISH
EVERPURE H-Series Water Filtration Systems 11
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
dna gniknird rof ytilauq muimerp ot retaw detaert sehsilop yleniF
cooking.
NSF/ANSI Standard 53 certied to reduce c ysts such as
Cryptosporidium and Giardia by mechanical means.
dna nori dezidixo( sediflus setalucitrap rehto dna tsur ,trid secudeR
manganese - As tested by Everpure).
slortnoC even extreme levels of common “o” tastes and odors,
including those which are earthy, moldy, and shy.
Reduces lead to be low the Federal Action L evel of 15 ppb.
( slacimehc cinagro elitalov secuder ylevi
tceffE VOCs), including
trihalomethanes (THMs).
Eectively reduces methyl tertiary-butyl ether (MTBE).
Reduces particles as small as 0.5 micron in size by mechanical
means.
ERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the sy stem was
reduced to a concentration less than or equal to the permissible
limit for water leaving the sy stem, as specied in NSF/ANSI 42
and 53.
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Eects
Chlorine 2.0 mg/L ± 10% ≥ 50% 86.8%
Chloramine 3.0 mg/L ± 10% 0.5 mg/L 98.3%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL ≥ 85% 98.8%
Standard 53—Health Eects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 6.5 0.15 mg/L ± 10% 0.005 mg/L 99.3% 99.3%
Lead 8.5 0.15 mg/L ± 10% 0.005 mg/L 98.7% 99.3%
Methyl tert-
butyl ether 0.015 mg/L ± 20% 0.005 mg/L 83.5% 91.5%
Chloroform 0.300 mg/L 0.015 mg/L 99.8% 99.8%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
EPA Est. 002623-IL-002
OPERATING SPECIFICATIONS
Capacity: 1,000 gallons (3,780L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
Performance Data Sheet Reduction Claims
for Organic Chemicals Included by Surrogate Testing
Substance Inuent Challenge
Concentration mg/L
Maximum Permissible Product
Water Concentration mg/L
alachlor 0.050 0.001
atrazine 0.100 0.003
benzene 0.081 0.001
carbofuran 0.190 0.001
carbon tetrachloride 0.078 0.0018
chlorobenzene 0.077 0.001
chloropicrin 0.015 0.0002
2,4-D 0.110 0.0017
dibromochloropropane (DBCP) 0.052 0.00002
o-dichlorobenzene 0.080 0.001
p-dichlorobenzene 0.040 0.001
1,2-dichloroethane 0.088 0.0048
1,1-dichloroethylene 0.083 0.001
cis-1,2-dichloroethylene 0.170 0.0005
trans-1,2-dichloroethylene 0.086 0.001
1,2-dichloropropane 0.080 0.001
cis-1,3-dichloropropylene 0.079 0.001
dinoseb 0.170 0.0002
endrin 0.053 0.00059
ethylbenzene 0.088 0.001
ethylene dibromide (EDB) 0.044 0.00002
haloacetonitriles (HAN):
bromochloroacentonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
0.0072
0.0082
0.0001
0.0003
heptachlor 0.080 0.0004
heptachlor epoxide 0.0107 0.0002
hexachlorobutadiene 0.044 0.001
hexachlorocyclopentadiene 0.060 0.000002
lindane 0.055 0.00001
methoxychlor 0.050 0.0001
pentachlorophenol 0.096 0.001
simazine 0.120 0.004
styrene 0.150 0.0005
1,1,2,2-tetrachloroethane 0.081 0.001
tetrachloroethylene 0.081 0.001
toluene 0.078 0.001
2,4,5-TP(silvex) 0.270 0.0016
tribromoacetic acid 0.042 0.001
1,2,4-trichlorobenzene 0.160 0.0005
1,1,1-trichloroethane 0.084 0.0046
1,1,2-trichloroethane 0.150 0.0005
trichloroethylene 0.180 0.001
trihalomethanes (includes):
chlor oform (surrogate
chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.300 0.015
xylenes (total) 0.070 0.001
H-1200 Cartridge - Part Nos. EV9282-01, EV9282-03
H-1200 DRINKING WATER SYSTEM
The H-1200 is Tested and Certied by NSF
International against CSA B483.1 and NSF/ANSI 42
and 53 for the claims specified on the Performance
Data Sheet.
C US
PER FORM ANCE DATA SHEE T
NOTE:
Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering lter.
PFOA/PFOS 0.0015 mg/L ± 10% 0.00007 mg/L 95.76% 97.57%
EVERPURE
EVERPURE H-Series Water Filtration Systems 11
H-104 Cartridge - Part No. EV9612-11, EV9612-16
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
dna gniknird rof yt i lauq muimerp ot retaw detaert sehsi lop yleniF
cooking.
Reduces chlorine taste and odor.
, nor i dez i d i xo sa hcus se t a l uc i t rap reht o dna t sur , t r i d secudeR
manganese, and sulfides.
NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Reduces common earthy, moldy, fishy tastes and odors.
Reduces lead to below the Federal Action Level.
Reduces particles as small as 0.5 micron in size by mechanical
means.
H-104 PERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ° 50% 87.8%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL ° 85% 98.8%
Standard 53—Health Effects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.010 mg/L 99.3% 99.3%
Lead 6.5 0.15 mg/L ± 10% 0.010 mg/L 98.7% 99.3%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
OPERATING SPECIFICATIONS
Capacity: 1,000 gallons (3,780L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2°-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
EPA Est. 002623-IL-002
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
gnidulcni )mc 15 x 31 x 31( .ni 02 x 5 x 5 :deriuqer ecapS
2½ inches of clear space under unit for cartridge change.
Install vertically with cartridge hanging down.
Use minimum length of tubing possible.
Flush new cartridge at full flow for three minutes to purge air.
semoceb wo l f nehw r o , dehcae r s i y t i capac nehw segd i r t r ac eca l peR
too slow, but at least annually.
SPECIAL NOTICES
Installation instructions, parts and service availability, and standard
warranty are included with the product.
This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges. Suggested retail $122.99.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
The contaminants or other substances removed or reduced by this
water treatment system are not necessarily in your water.
Check for compliance with state and local laws and regulations.
Tested under standard laboratory conditions, actual performance
may vary.
Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
System Tested and Certified by NSF International against
CSA B483.1 and NSF/ANSI 42 and 53 for the claims
specified on the Performance Data Sheet.
H-104 DRINKING WATER SYSTEMS
C US
PERFORMANCE DATA SHEET
The H-1200 is Tested and Certified by NSF
International against CSA B483.1 and NSF/ANSI 42
and 53 for the claims specified on the Performance
Data Sheet.
EPA Est. No. 002623-IL-002
The H-1200 is certied by IAPMO R&T against
NSF/ANSI 53 for the reduction of peruorooctanoic
acid (PFOA) and peruorooctane sulfonate (PFOS).
ENGLISH
12EVERPURE H-Series Water Filtration Systems
H300HSD CARTRIDGE  PART NO. EV927074,
EV927075
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a
water treatment unit, you have your water tested to determine
your actual treatment needs.
FEATURES
For high silt density water vs. standard H-300.
Finely polishes treated water to premium quality for
drinking and cooking.
Reduces chlorine taste and odor.
Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and sulfides.
NSF/ANSI Standard 53 certied to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Controls even extreme levels of common "off" taste and odors,
including those which are earthy, moldy, and fishy.
Reduces lead to below the Federal Action Level of 15 ppb.
Effectively reduces Volatile Organic Chemicals (VOCs),
Effectively reduces methyl tertiary-butyl ether (MTBE).
Reduces particles as small as 0.5 micron in size by
mechanical means.
H-300-HSD Performance Data
This system has been tested according to NSF/ANSI 42 and 53
for the reduction of the substances listed below.
The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specified
in NSF/ANSI 42 and 53.
NOTE: Spent adsorption media will not be regenerated and
used. If adsorption media is affected by chlorine, water supply
should be treated to remove chlorine prior to entering filter.
PERFORMANCE DATA SHEET
H300HSD DRINKING WATER SYSTEMS
OPERATING SPECIFICATIONS
• Capacity: 300 gallons (1,135L)
• Pressure Requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
• Temperature: 35-100°F (2°-38°C)
• Flow Rate: 0.5 gpm (1.9 Lpm
PERFORMANCE DATA SHEET REDUCTION CLAIMS FOR
ORGANIC CHEMICALS INCLUDED BY SURROGATE TESTING
ENGLISH
12EVERPURE H-Series Water Filtration Systems
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
For high silt density water vs. standard H-300.
Finely polishes treated water to premium quality for drinking and
cooking.
Reduces chlorine taste and odor.
Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and suldes.
NSF/ANSI Standard 53 certied to reduce c ysts such as
Cryptosporidium and Giardia by mechanical means.
Controls even extreme levels of common “o” tastes and odors,
including those which are earthy, moldy and shy.
Reduces lead to bel ow the Federal Action Le vel of 15 ppb.
Eectively reduces Volatile Organic Chemicals (V OCs).
Reduces particles as small as 0.5 micron in size by mechanical
means.
ERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the sy stem was reduced
to a concentration less than or equal to the permissible limit for
water leaving the sy stem, as specied in NSF/ANSI 42 and 53.
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Eects
Chlorine 2.0 mg/L ± 10% ≥ 50% 86.8%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL ≥ 85% 98.8%
Standard 53—Health Eects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 6.5 0.15 mg/L ± 10% 0.005 mg/L 99.3% 99.3%
Lead 8.5 0.15 mg/L ± 10% 0.005 mg/L 98.7% 99.3%
Chloroform 0.300 mg/L 0.015 mg/L 95.8% 98.9%
(VOC surrogate chemical)
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
EPA Est. 002623-IL-002
OPERATING SPECIFICATIONS
Capacity: 300 gallons (1,135L)
Pressure Requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
Performance Data Sheet Reduction Claims
for Organic Chemicals Included by Surrogate Testing
Substance Inuent Challenge
Concentration mg/L
Maximum Permissible Product
Water Concentration mg/L
alachlor 0.050 0.001
atrazine 0.100 0.003
benzene 0.081 0.001
carbofuran 0.190 0.01
carbon tetrachloride 0.078 0.0018
chlorobenzene 0.077 0.001
chloropicrin 0.015 0.0002
2,4-D 0.110 0.0017
dibromochloropropane (DBCP) 0.052 0.00002
o-dichlorobenzene 0.080 0.001
p-dichlorobenzene 0.040 0.001
1,2-dichloroethane 0.088 0.0048
1,1-dichloroethylene 0.083 0.001
cis-1,2-dichloroethylene 0.170 0.0005
trans-1,2-dichloroethylene 0.086 0.001
1,2-dichloropropane 0.080 0.001
cis-1,3-dichloropropylene 0.079 0.001
dinoseb 0.170 0.0002
endrin 0.053 0.00059
ethylbenzene 0.088 0.001
ethylene dibromide (EDB) 0.044 0.00002
haloacetonitriles (HAN):
bromochloroacentonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
0.0072
0.0082
0.0001
0.0003
heptachlor 0.080 0.0004
heptachlor epoxide 0.0107 0.0002
hexachlorobutadiene 0.044 0.001
hexachlorocyclopentadiene 0.060 0.000002
lindane 0.055 0.00001
methoxychlor 0.050 0.0001
pentachlorophenol 0.096 0.001
simazine 0.120 0.004
styrene 0.150 0.0005
1,1,2,2-tetrachloroethane 0.081 0.001
tetrachloroethylene 0.081 0.001
toluene 0.078 0.001
2,4,5-TP(silvex) 0.270 0.0016
tribromoacetic acid 0.042 0.001
1,2,4-trichlorobenzene 0.160 0.0005
1,1,1-trichloroethane 0.084 0.0046
1,1,2-trichloroethane 0.050 0.0005
trichlor oethylene 0.180 0.001
trihalomethanes (includes):
chloroform (surrogate
chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.300 0.015
xylenes (total) 0.070 0.001
H-300-HSD Cartridge - Part Nos. EV9270-74, EV9270-75
H-300-HSD DRINKING WATER SYSTEM
The H-300-HSD is Tested and Certied by NSF
International against CSA B483.1 and NSF/ANSI 42
and 53 for the claims specied on the
Performance Data Sheet.
C US
PER FORM ANCE DATA SHEE T
NOTE:
Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering lter.
EVERPURE
EVERPURE
H-104 Cartridge - Part No. EV9612-11, EV9612-16
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
dna gniknird rof yt i lauq muimerp ot retaw detaert sehsi lop yleniF
cooking.
Reduces chlorine taste and odor.
, nor i dez i d i xo sa hcus se t a l uc i t rap reht o dna t sur , t r i d secudeR
manganese, and sulfides.
NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Reduces common earthy, moldy, fishy tastes and odors.
Reduces lead to below the Federal Action Level.
Reduces particles as small as 0.5 micron in size by mechanical
means.
H-104 PERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ° 50% 87.8%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL ° 85% 98.8%
Standard 53—Health Effects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.010 mg/L 99.3% 99.3%
Lead 6.5 0.15 mg/L ± 10% 0.010 mg/L 98.7% 99.3%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
OPERATING SPECIFICATIONS
Capacity: 1,000 gallons (3,780L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2°-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
EPA Est. 002623-IL-002
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
gnidulcni )mc 15 x 31 x 31( .ni 02 x 5 x 5 :deriuqer ecapS
2½ inches of clear space under unit for cartridge change.
Install vertically with cartridge hanging down.
Use minimum length of tubing possible.
Flush new cartridge at full flow for three minutes to purge air.
semoceb wo l f nehw r o , dehcae r s i y t i capac nehw segd i r t r ac eca l peR
too slow, but at least annually.
SPECIAL NOTICES
Installation instructions, parts and service availability, and standard
warranty are included with the product.
This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges. Suggested retail $122.99.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
The contaminants or other substances removed or reduced by this
water treatment system are not necessarily in your water.
Check for compliance with state and local laws and regulations.
Tested under standard laboratory conditions, actual performance
may vary.
Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
System Tested and Certified by NSF International against
CSA B483.1 and NSF/ANSI 42 and 53 for the claims
specified on the Performance Data Sheet.
H-104 DRINKING WATER SYSTEMS
C US
PERFORMANCE DATA SHEET
The H-300-HSD is Tested and Certified by NSF
International against CSA B483.1 and NSF/ANSI 42
and 53 for the claims specified on the Performance
Data Sheet.
EPA Est. No. 002623-IL-002
ENGLISH
12EVERPURE H-Series Water Filtration Systems
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
For high silt density water vs. standard H-300.
Finely polishes treated water to premium quality for drinking and
cooking.
Reduces chlorine taste and odor.
Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and suldes.
NSF/ANSI Standard 53 certied to reduce c ysts such as
Cryptosporidium and Giardia by mechanical means.
Controls even extreme levels of common “o” tastes and odors,
including those which are earthy, moldy and shy.
Reduces lead to bel ow the Federal Action Le vel of 15 ppb.
Eectively reduces Volatile Organic Chemicals (V OCs).
Reduces particles as small as 0.5 micron in size by mechanical
means.
ERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the sy stem was reduced
to a concentration less than or equal to the permissible limit for
water leaving the sy stem, as specied in NSF/ANSI 42 and 53.
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Eects
Chlorine 2.0 mg/L ± 10% ≥ 50% 86.8%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL ≥ 85% 98.8%
Standard 53—Health Eects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 6.5 0.15 mg/L ± 10% 0.005 mg/L 99.3% 99.3%
Lead 8.5 0.15 mg/L ± 10% 0.005 mg/L 98.7% 99.3%
Chloroform 0.300 mg/L 0.015 mg/L 95.8% 98.9%
(VOC surrogate chemical)
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
EPA Est. 002623-IL-002
OPERATING SPECIFICATIONS
Capacity: 300 gallons (1,135L)
Pressure Requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
Performance Data Sheet Reduction Claims
for Organic Chemicals Included by Surrogate Testing
Substance Inuent Challenge
Concentration mg/L
Maximum Permissible Product
Water Concentration mg/L
alachlor 0.050 0.001
atrazine 0.100 0.003
benzene 0.081 0.001
carbofuran 0.190 0.01
carbon tetrachloride 0.078 0.0018
chlorobenzene 0.077 0.001
chloropicrin 0.015 0.0002
2,4-D 0.110 0.0017
dibromochloropropane (DBCP) 0.052 0.00002
o-dichlorobenzene 0.080 0.001
p-dichlorobenzene 0.040 0.001
1,2-dichloroethane 0.088 0.0048
1,1-dichloroethylene 0.083 0.001
cis-1,2-dichloroethylene 0.170 0.0005
trans-1,2-dichloroethylene 0.086 0.001
1,2-dichloropropane 0.080 0.001
cis-1,3-dichloropropylene 0.079 0.001
dinoseb 0.170 0.0002
endrin 0.053 0.00059
ethylbenzene 0.088 0.001
ethylene dibromide (EDB) 0.044 0.00002
haloacetonitriles (HAN):
bromochloroacentonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
0.0072
0.0082
0.0001
0.0003
heptachlor 0.080 0.0004
heptachlor epoxide 0.0107 0.0002
hexachlorobutadiene 0.044 0.001
hexachlorocyclopentadiene 0.060 0.000002
lindane 0.055 0.00001
methoxychlor 0.050 0.0001
pentachlorophenol 0.096 0.001
simazine 0.120 0.004
styrene 0.150 0.0005
1,1,2,2-tetrachloroethane 0.081 0.001
tetrachloroethylene 0.081 0.001
toluene 0.078 0.001
2,4,5-TP(silvex) 0.270 0.0016
tribromoacetic acid 0.042 0.001
1,2,4-trichlorobenzene 0.160 0.0005
1,1,1-trichloroethane 0.084 0.0046
1,1,2-trichloroethane 0.050 0.0005
trichlor oethylene 0.180 0.001
trihalomethanes (includes):
chloroform (surrogate
chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.300 0.015
xylenes (total) 0.070 0.001
H-300-HSD Cartridge - Part Nos. EV9270-74, EV9270-75
H-300-HSD DRINKING WATER SYSTEM
The H-300-HSD is Tested and Certied by NSF
International against CSA B483.1 and NSF/ANSI 42
and 53 for the claims specied on the
Performance Data Sheet.
C US
PER FORM ANCE DATA SHEE T
NOTE:
Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering lter.
EVERPURE
ENGLISH
EVERPURE H-Series Water Filtration Systems 13
H300NXT CARTRIDGE  PART NO. EV927441,
EV927446
IMPORTANT NOTICE: Read this Everpure Performance Data
Sheet and compare the capabilities of this unit with your
actual water treatment needs. It is recommended that, before
purchasing a water treatment unit, you have your water tested
to determine your actual treatment needs.
FEATURES
Finely polishes treated water to premium quality for
drinking and cooking.
NSF/ANSI Standard 53 certied to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Reduces dirt, rust and other particulates sulfides (oxidized iron
and manganese As tested by Everpure).
Controls even extreme levels of common "off" taste and odors,
including those which are earthy, moldy, and fishy.
Reduces lead to below the Federal Action Level of 15 ppb.
Effectively reduces Volatile Organic Chemicals (VOCs),
including Trihalomethanes (THMs).
Effectively reduces methyl tertiary-butyl ether (MTBE).
Reduces particles as small as 0.5 micron in size by
mechanical means.
H-300-NXT Performance Data
This system has been tested according to NSF/ANSI 42, 53,
and 401 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specified
in NSF/ANSI 42, 53, and 401.
NOTE: Spent adsorption media will not be regenerated and
used. If adsorption media is affected by chlorine, water supply
should be treated to remove chlorine prior to entering filter.
PERFORMANCE DATA SHEET
H300NXT DRINKING WATER SYSTEM
OPERATING SPECIFICATIONS
• Capacity: 300 gallons (1,136L)
• Pressure Requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
• Temperature: 35-100°F (2°-38°C)
• Flow Rate: 0.5 gpm (1.9 Lpm
PERFORMANCE DATA SHEET REDUCTION CLAIMS FOR
ORGANIC CHEMICALS INCLUDED BY SURROGATE TESTING
ENGLISH
EVERPURE H-Series Water Filtration Systems 13
IMPORTANT NOTICE:
Read this Everpure* Performance Data Sheet
and compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
Finely polishes treated water to premium quality for drinking and cooking.
Reduces chlorine taste and odor.
Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and suldes - As tested by Pentair.
NSF/ANSI Standard 53 certied to reduce c ysts such as Cryptosporidium
and Giardia by mechanical means.
Controls even extreme levels of common “o” tastes and odors, including
those which are earthy, moldy and shy.
Reduces lead.
Eectively reduces Volatile Organic Chemicals (VOCs).
Reduces particles as small as 0.5 micron in size by mechanical means.
NSF/ANSI Standard 401 certied for the reduction of the incidental
contaminants/emerging compounds listed in the performance data sheet.
ERFORMANCE ATA
This system has been tested ac cording to NSF/ANSI 42, 53 and 401
for the reduction of the substances listed bel ow. The concentration of
the indicated substances in water entering the s ystem was reduced to
a concentration less than or equal to the permissible limit for water
leaving the s ystem, as specied in NSF/ANSI 42, 53 and 401.
Substance
Influent
Challenge
Concentration
Max.
Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Eects
Chlorine 2.0 mg/L ± 10% ≥ 50% 86.8%
Particulate, Class I
particles 0.5 to <1 µm
at least 10,000
particles/mL ≥ 85% 98.8%
Standard 53—Health Eects
Cyst Minimum 50,000/L 99.95% 99.99 99.99%
Lead 6.5 0.15 mg/L ± 10% 0.005 mg/L 99.3% 99.3%
Lead 8.5 0.15 mg/L ± 10% 0.005 mg/L 98.7% 99.3%
Chloroform 0.300 mg/L 0.015 mg/L 95.8% 98.9%
(VOC surrogate chemical)
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
Standard 401—Emerging Contaminants
Phenytoin 200 ± 20% ng/L 0.000030 mg/L >96.3%
Ibuprofen 400 ± 20% ng/L 0.000060 mg/L >95.8%
Naproxen 140 ± 20% ng/L 0.000020 mg/L >96.8%
Estrone 140 ± 20% ng/L 0.000020 mg/L >97.2%
Bisphenol A (BPA) 2,000 ± 20% ng/L 0.000300 mg/L >99.2%
Nonylphenol 1,400 ± 20% ng/L 0.000200 mg/L >97.1%
NSF/ANSI Standard 401 have been deemed as “incidental contaminants/emerging compounds”.
Incidental contaminants are those compounds that have been detected in drinking water supplies at
trace levels. While occurring at only trace levels, these compounds can aect the public acceptance/
perception of drinking water quality.
OPERATING SPECIFICATIONS
Capacity: 300 gallons (1,136L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
Performance Data Sheet Reduction Claims
for Organic Chemicals Included by Surrogate Testing
Substance Inuent Challenge
Concentration mg/L
Maximum Permissible Product
Water Concentration mg/L
alachlor 0.050 0.001
atrazine 0.100 0.003
benzene 0.081 0.001
carbofuran 0.190 0.001
carbon tetrachloride 0.078 0.0018
chlorobenzene 0.077 0.001
chloropicrin 0.015 0.0002
2,4-D 0.110 0.0017
dibromochloropropane (DBCP) 0.052 0.00002
o-dichlorobenzene 0.080 0.001
p-dichlorobenzene 0.040 0.001
1,2-dichloroethane 0.088 0.0048
1,1-dichloroethylene 0.083 0.001
cis-1,2-dichloroethylene 0.170 0.0005
trans-1,2-dichloroethylene 0.086 0.001
1,2-dichloropropane 0.080 0.001
cis-1,3-dichloropropylene 0.079 0.001
dinoseb 0.170 0.0002
endrin 0.053 0.00059
ethylbenzene 0.088 0.001
ethylene dibromide (EDB) 0.044 0.00002
haloacetonitriles (HAN):
bromochloroacentonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
0.0072
0.0082
0.0001
0.0003
heptachlor 0.080 0.0004
heptachlor epoxide 0.0107 0.0002
hexachlorobutadiene 0.044 0.001
hexachlorocyclopentadiene 0.060 0.000002
lindane 0.055 0.00001
methoxychlor 0.050 0.0001
pentachlorophenol 0.096 0.001
simazine 0.120 0.004
styrene 0.150 0.0005
1,1,2,2-tetrachloroethane 0.081 0.001
tetrachloroethylene 0.081 0.001
toluene 0.078 0.001
2,4,5-TP(silvex) 0.270 0.0016
tribromoacetic acid 0.042 0.001
1,2,4-trichlorobenzene 0.160 0.0005
1,1,1-trichloroethane 0.084 0.0046
1,1,2-trichlor oethane 0.150 0.0005
trichl oroethylene 0.180 0.001
trihalomethanes (includes):
chloroform (surrogate
chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.300 0.015
xylenes (total) 0.070 0.001
H-300-NXT Cartridge - Part Nos. EV927441, EV927446
H-300-NXT DRINKING WATER SYSTEM
EPA Est. 002623-IL-002
The H-300-NXT is Tested and Certied by NSF
International against CSA B483.1 and NSF/ANSI
42, 53, and 401 for the claims specied on the
Performance Data Sheet.
C US
PER FORM ANCE DATA SHEE T
NOTE:
Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering lter.
EVERPURE
EVERPURE
ENGLISH
EVERPURE H-Series Water Filtration Systems 13
IMPORTANT NOTICE:
Read this Everpure* Performance Data Sheet
and compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
Finely polishes treated water to premium quality for drinking and cooking.
Reduces chlorine taste and odor.
Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and suldes - As tested by Pentair.
NSF/ANSI Standard 53 certied to reduce c ysts such as Cryptosporidium
and Giardia by mechanical means.
Controls even extreme levels of common “o” tastes and odors, including
those which are earthy, moldy and shy.
Reduces lead.
Eectively reduces Volatile Organic Chemicals (VOCs).
Reduces particles as small as 0.5 micron in size by mechanical means.
NSF/ANSI Standard 401 certied for the reduction of the incidental
contaminants/emerging compounds listed in the performance data sheet.
ERFORMANCE ATA
This system has been tested ac cording to NSF/ANSI 42, 53 and 401
for the reduction of the substances listed bel ow. The concentration of
the indicated substances in water entering the s ystem was reduced to
a concentration less than or equal to the permissible limit for water
leaving the s ystem, as specied in NSF/ANSI 42, 53 and 401.
Substance
Influent
Challenge
Concentration
Max.
Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Eects
Chlorine 2.0 mg/L ± 10% ≥ 50% 86.8%
Particulate, Class I
particles 0.5 to <1 µm
at least 10,000
particles/mL ≥ 85% 98.8%
Standard 53—Health Eects
Cyst Minimum 50,000/L 99.95% 99.99 99.99%
Lead 6.5 0.15 mg/L ± 10% 0.005 mg/L 99.3% 99.3%
Lead 8.5 0.15 mg/L ± 10% 0.005 mg/L 98.7% 99.3%
Chloroform 0.300 mg/L 0.015 mg/L 95.8% 98.9%
(VOC surrogate chemical)
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
Standard 401—Emerging Contaminants
Phenytoin 200 ± 20% ng/L 0.000030 mg/L >96.3%
Ibuprofen 400 ± 20% ng/L 0.000060 mg/L >95.8%
Naproxen 140 ± 20% ng/L 0.000020 mg/L >96.8%
Estrone 140 ± 20% ng/L 0.000020 mg/L >97.2%
Bisphenol A (BPA) 2,000 ± 20% ng/L 0.000300 mg/L >99.2%
Nonylphenol 1,400 ± 20% ng/L 0.000200 mg/L >97.1%
NSF/ANSI Standard 401 have been deemed as “incidental contaminants/emerging compounds”.
Incidental contaminants are those compounds that have been detected in drinking water supplies at
trace levels. While occurring at only trace levels, these compounds can aect the public acceptance/
perception of drinking water quality.
OPERATING SPECIFICATIONS
Capacity: 300 gallons (1,136L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
Performance Data Sheet Reduction Claims
for Organic Chemicals Included by Surrogate Testing
Substance Inuent Challenge
Concentration mg/L
Maximum Permissible Product
Water Concentration mg/L
alachlor 0.050 0.001
atrazine 0.100 0.003
benzene 0.081 0.001
carbofuran 0.190 0.001
carbon tetrachloride 0.078 0.0018
chlorobenzene 0.077 0.001
chloropicrin 0.015 0.0002
2,4-D 0.110 0.0017
dibromochloropropane (DBCP) 0.052 0.00002
o-dichlorobenzene 0.080 0.001
p-dichlorobenzene 0.040 0.001
1,2-dichloroethane 0.088 0.0048
1,1-dichloroethylene 0.083 0.001
cis-1,2-dichloroethylene 0.170 0.0005
trans-1,2-dichloroethylene 0.086 0.001
1,2-dichloropropane 0.080 0.001
cis-1,3-dichloropropylene 0.079 0.001
dinoseb 0.170 0.0002
endrin 0.053 0.00059
ethylbenzene 0.088 0.001
ethylene dibromide (EDB) 0.044 0.00002
haloacetonitriles (HAN):
bromochloroacentonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
0.0072
0.0082
0.0001
0.0003
heptachlor 0.080 0.0004
heptachlor epoxide 0.0107 0.0002
hexachlorobutadiene 0.044 0.001
hexachlorocyclopentadiene 0.060 0.000002
lindane 0.055 0.00001
methoxychlor 0.050 0.0001
pentachlorophenol 0.096 0.001
simazine 0.120 0.004
styrene 0.150 0.0005
1,1,2,2-tetrachloroethane 0.081 0.001
tetrachloroethylene 0.081 0.001
toluene 0.078 0.001
2,4,5-TP(silvex) 0.270 0.0016
tribromoacetic acid 0.042 0.001
1,2,4-trichlorobenzene 0.160 0.0005
1,1,1-trichloroethane 0.084 0.0046
1,1,2-trichlor oethane 0.150 0.0005
trichl oroethylene 0.180 0.001
trihalomethanes (includes):
chloroform (surrogate
chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.300 0.015
xylenes (total) 0.070 0.001
H-300-NXT Cartridge - Part Nos. EV927441, EV927446
H-300-NXT DRINKING WATER SYSTEM
EPA Est. 002623-IL-002
The H-300-NXT is Tested and Certied by NSF
International against CSA B483.1 and NSF/ANSI
42, 53, and 401 for the claims specied on the
Performance Data Sheet.
C US
PER FORM ANCE DATA SHEE T
NOTE: Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering lter.
EVERPURE
H-104 Cartridge - Part No. EV9612-11, EV9612-16
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
dna gniknird rof yt i lauq muimerp ot retaw detaert sehsi lop yleniF
cooking.
Reduces chlorine taste and odor.
, nor i dez i d i xo sa hcus se t a l uc i t rap reht o dna t sur , t r i d secudeR
manganese, and sulfides.
NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Reduces common earthy, moldy, fishy tastes and odors.
Reduces lead to below the Federal Action Level.
Reduces particles as small as 0.5 micron in size by mechanical
means.
H-104 PERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ° 50% 87.8%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL ° 85% 98.8%
Standard 53—Health Effects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.010 mg/L 99.3% 99.3%
Lead 6.5 0.15 mg/L ± 10% 0.010 mg/L 98.7% 99.3%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
OPERATING SPECIFICATIONS
Capacity: 1,000 gallons (3,780L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2°-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
EPA Est. 002623-IL-002
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
gnidulcni )mc 15 x 31 x 31( .ni 02 x 5 x 5 :deriuqer ecapS
2½ inches of clear space under unit for cartridge change.
Install vertically with cartridge hanging down.
Use minimum length of tubing possible.
Flush new cartridge at full flow for three minutes to purge air.
semoceb wo l f nehw r o , dehcae r s i y t i capac nehw segd i r t r ac eca l peR
too slow, but at least annually.
SPECIAL NOTICES
Installation instructions, parts and service availability, and standard
warranty are included with the product.
This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges. Suggested retail $122.99.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
The contaminants or other substances removed or reduced by this
water treatment system are not necessarily in your water.
Check for compliance with state and local laws and regulations.
Tested under standard laboratory conditions, actual performance
may vary.
Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
System Tested and Certified by NSF International against
CSA B483.1 and NSF/ANSI 42 and 53 for the claims
specified on the Performance Data Sheet.
H-104 DRINKING WATER SYSTEMS
C US
PERFORMANCE DATA SHEET
The H-300-NXT is Tested and Certified by NSF
International against CSA B483.1 and NSF/
ANSI 42 and 53 for the claims specified on the
Performance Data Sheet.
EPA Est. No. 002623-IL-002
ESPAÑOL
14EVERPURE Sistema De Filtración De Agua De La Serie H
Gracias por comprar un Everpure*sistema de ltración
de agua Everpure de categoría comercial para su hogar.
Con el sistema Everpure usted obtiene directamente
de la llave un agua de primera calidad de buen sabor
en forma conveniente para usted y su familia.
Especicaciones Del Producto:
•Para uso únicamente con agua fría
•Gama de temperatura: 2-38°C (35-100°F)
•Presión de servicio mín. - máx.:
0.7-8.6 bar (10-125 psi)
•Caudal de servicio: 1.9 Lpm (0.5 gpm)
EL MANUAL DEL USUARIO SE APLICA A LOS
SIGUIENTES MODELOS DE FILTRO EVERPURE:
Modelo H-54 Capacidad nominal: 750 Gal
(2,839 L)
Modelo H-300 Capacidad nominal: 300 Gal
(1,136 L)
Modelo H-104 Capacidad nominal: 1,000 Gal
(3,785 L)
Modelo H-300-HSD Capacidad nominal: 300 Gal
(1,136 L)
Modelo H-300-NXT Capacidad nominal: 300 Gal
(1,136 L)
Modelo H-1200 Capacidad nominal:1,000 Gal
(3,785 L)
Para mayor rendimiento, el cartucho debe ser reemplazado una
vez al año o antes si el caudal se vuelve demasiado lento para su
conveniencia o si se alcanza la capacidad nominal de la unidad.
Para la compra de componentes reemplazables por favor
póngase en contacto con su distribuidor local.
Usuarios del H-1200: Las instrucciones para la instalación
del H-1200 comienzan en la página no 15 de este Manual de
Instalación y Funcionamiento.
El Código Universal de Plomería (EE.UU.) adoptado
por más de 20 estados y otros códigos estatales y de condados
especícos prohíben el uso de válvulas de montura y su uso no es
nunca recomendado. Usted debe cumplir con los códigos estatales o
locales. Consulte con un plomero licenciado si tiene preguntas sobre
esto.
NO use tubería de cobre con las conexiones John
Guest suministradas con su Sistema de Filtración Everpure. Podría
parecer que la tubería de cobre encaja pero con el tiempo y el uso
se desarrollarán pérdidas de agua. Si es necesario usar tubos de
cobre, debe usar conectores de compresión de cobre disponibles en
cualquier tienda de plomería o ferretería.
Conexiones para electrodomésticos múltiples: También puede
conectar su Filtro Everpure al refrigerador para el surtidor de hielo
y agua, a un surtidor instantáneo de agua caliente o fría o a una
cafetera instalada. Simplemente instale conectores en T (disponibles
en cualquier tienda de plomería o ferretería) en la línea de agua entre
el ltro y el adaptador del grifo, y extienda instale
una tubería nueva
hacia cada uno de los electrodomésticos.
NOTA:
NO conecte este sistema a una máquina comercial de hacer
hielo. Estas máquinas requieren un caudal y un volumen mayor que
los límites de diseño de su sistema de ltración debajo del fregadero.
NOTA:
Si lo conecta a una máquina de hacer hielo casera y no hay una
conexión para un ltro de grifo debajo del fregadero: se
necesita una
válvula de descarga.
ESPAÑOL
EVERPURE Sistema De Filtración De Agua De La Serie H 15
2
INSTRUCCIONES BÁSICAS DE INSTALACIÓN
Herramientas necesarias
Destornillador #2 Phillips • Llave • Cuchillo universal
Cinta métrica • Lápiz
1. ABRA EL CARTÓN Y REVISE LAS PIEZAS
Piezas de instalación
Clave Descripción Pieza No
1 QL3 Cabezal de ltro
(Cantidad Incluyó 2 cada uno
de 3 y 4)
EV925831
2Cartucho ltrante
(incluye
10
)
– Modelo H-54 EV925268
– Modelo H-300 EV927072
– Modelo H-104 EV961211
– Modelo H-300-HSD EV927075
– Modelo H-300-NXT EV927441
3 arandelas de seguridad
(requiere 2)
EV306204
4tornillos
(requiere 2)
EV306196
5 Adaptador para válvula de
cierre en ángulo EV312120
6
Tubería de plástico de 0.64 cm
(por 30.48 cm) A0860119
7 Codo adaptador y reductor
(Cantidad Incluyó 2 cada uno
de
3
y 4
)
EV308168
8 Cinta de Fontanero EV312119
9 Conector de grifo EV312135
10 Medidor de ltro Everpure EV314160
2. COMPRUEBE EL SITIO DE MONTAJE DEBAJO DEL FREGADERO
Mida 55.8 cm desde la base del armario y marque el sitio de
montaje de la parte superior del cabezal del ltro. Asegúrese
de que haya suciente espacio encima del cabezal para abrir
y cerrar la válvula de cierre incorporada y para evitar que la
tubería de agua se doble. También, asegúrese de que el sitio que
escogió sea fácilmente accesible para cambiar los cartuchos en
el futuro.
Dimensiones Ancho Altura Profundidad
H-54 12.7 cm 38.1 cm 12.7 cm
H-104 12.7 cm 50.8 cm 12.7 cm
H-300 12.7 cm 55.8 cm 12.7 cm
H-300-HSD 12.7 cm 55.8 cm 12.7 cm
H-300-NXT 12.7 cm 55.8 cm 12.7 cm
NOTA:
El cabezal y el cartucho deben montarse en posición
vertical, con el cartucho colgando hacia abajo.
1
1
2
35
67
8
9
10
4
55.8 cm
ESPAÑOL
16EVERPURE Sistema De Filtración De Agua De La Serie H
3. MONTE EL CABEZAL DEL FILTRO DEBAJO DEL FREGADERO
A. Identique el cabezal de ltro y los dos codos
adaptadores y note que el adaptador de salida tiene
una banda negra. Este adaptador incluye un pequeño
accesorio reductor para asegurar un ujo máximo de 1,9
litros por minuto.
B. Aplique cinta de plomería a las roscas de cada codo
adaptador. Enrolle la cinta en el sentido de las roscas
para asegurar un ajuste rme y evitar las pérdidas
pequeñas.
C. Enrosque el codo adaptador de entrada al lado izquierdo
del cabezal de ltro y sólo apriete a mano.
D. Enrosque el codo adaptador de salida (banda negra) al
lado derecho del cabezal de ltro de la misma manera.
E. Monte rmemente el cabezal del ltro a la pared de
armarios usando los tornillos de montaje y las arandelas
incluidas.
4. CONECTE EL ABASTECIMIENTO DE AGUA DE ENTRADA
F. Ubique y cierre la válvula de cierre de agua fría en ángulo
debajo del fregadero de la cocina. Abra la llave de agua
fría del grifo para descargar la presión del agua.
G. Destornille y desconecte el tubo trenzado de la parte
superior de la válvula de cierre en ángulo.
H. Acople la parte inferior del adaptador de cierre en ángulo
a la válvula de cierre en ángulo existente para el agua fría.
I. Acople el tubo trenzado a la parte superior del adaptador
de cierre en ángulo.
J. Cierre la válvula del costado del adaptador de cierre en
ángulo y abra la válvula de cierre en ángulo para el agua
fría para restituir el servicio de agua al fregadero de la
cocina. Verique si hay pérdidas.
NOTA:
No se necesitará cinta de Fontanero para los
próximos pasos.
K. Mida el largo del tubo necesario para conectar el
adaptador de cierre en ángulo al codo adaptador de
entrada en el cabezal de ltro. Deje suciente tubo para
evitar vueltas agudas.
L. Corte el tubo a 90° usando un cuchillo loso.
M. Introduzca las puntas del tubo en los empalmes de
conexión rápida. Empuje el tubo dentro de la conexión y
tire suavemente para conrmar que el ajuste es rme.
5. CONECTE EL AGUA FILTRADA AL GRIFO DEL FREGADERO
N. Instale un grifo separado para agua potable ltrada. Siga
las instrucciones especícas del fabricante.
O. Acople el conector del grifo a la punta inferior de la rosca
del nuevo conjunto de grifo. No se necesitará cinta de
Fontanero para este paso.
P. Mida el largo del tubo necesario para conectar el codo
adaptador de salida en el cabezal de ltro al conector
del grifo. Deje suciente tubo para evitar vueltas
agudas. Corte e introduzca cada punta del tubo en los
conectores.
6. INSTALE EL CARTUCHO FILTRANTE Y DEJE CORRER EL
AGUA
3BCD
E
GH
I
LM
4
F
O
N
5
P
ESPAÑOL
EVERPURE Sistema De Filtración De Agua De La Serie H 17
Q. Levante la manilla de la válvula de cierre (válvula de
control) en el cabezal.
R. Sujete rmemente el cabezal con una mano.
S. Alinee la lengüeta del cartucho con la etiqueta del
cabezal del ltro.
T. Introduzca el cartucho ltrante—empuje hacia arriba.
U. Gírelo hacia la derecha, aproximadamente un 1/4 de
vuelta hasta que tope.
V. Abra la válvula de agua fría y compruebe que no haya
pérdidas hasta el adaptador del codo de entrada.
W. Abra el grifo de agua.
X. Baje la manilla de la válvula de control para descargar el
agua hacia el fregadero.
NOTA:
Deje correr agua por el cartucho ltrante nuevo
por lo menos durante 5 minutos para quitar el aire y toda
partícula suelta de carbono. Al principio, el agua ltrada
pudiera aparecer turbia debido al aire atrapado en el ltro
y la tubería. Si el agua continúa opaca por más de una
semana, póngase en contacto con el departamento de
Servicios Técnicos para que le ayuden: (800) 942-1153
Y. Active el temporizador del ltro presionando la burbuja
hasta que sienta un cambio en la resistencia cuando
se bote el temporizador. En unos pocos segundos
aparecerá una línea ROJA delgada en la ventana blanca
para mostrar que ya se activó el Timestrip. Desprenda
el protector y adhiéralo al sitio donde lo requiera.
Cuando la ventana blanca esté completamente llena de
ROJO, será momento de reemplazar su producto.
H-1200 INSTRUCCIONES DE INSTALACIÓN
Herramientas necesarias
Destornillador #2 Phillips • Cinta métrica
Llave • Lápiz
Cuchillo universal
1. OUVREZ LE CARTON ET INSPECTEZ LES PIÈCES
Pièces à installer
Clave Descripción Pieza No
1 Cabezal de ltro N/A
2H-1200 Cartucho ltrante
(conjunto de 2)
(incluye
10
)
EV928201
3Arandelas de seguridad
(requiere 2) EV306204
4 Tornillos (requiere 2) EV306196
5Adaptador para válvula de
cierre en ángulo EV312120
6
Tubería de plástico de 0.64 cm
(por 30.48 cm) A0860119
7Codo adaptador y reductor
(Cantidad Incluyó 2 cada uno
de # 3 y # 4) EV308168
8 Cinta de Fontanero EV312119
9 Conector de grifo EV312135
10 Medidor de ltro Everpure EV314160
11 Válvula de cierre, 3/8"
John
Guest
x 3/8" hembra EV309860
12 Acoplador, 3/8" hembra
inoxidable EV312350
1
1
2
3 5
6
7
8
9
10
11
12
4
Q
R
S
T
Etiqueta
Lengüeta
U
X
6
V W
Y
ESPAÑOL
18EVERPURE Sistema De Filtración De Agua De La Serie H
2. COMPRUEBE EL SITIO DE MONTAJE DEBAJO DEL FREGADERO
Mida 55.8 cm desde la base del armario y marque el sitio de
montaje de la parte superior del cabezal del ltro. Asegúrese
de que haya suciente espacio encima del cabezal para abrir
y cerrar la válvula de cierre incorporada y para evitar que la
tubería de agua se doble. También, asegúrese de que el sitio que
escogió sea fácilmente accesible para cambiar los cartuchos en
el futuro.
Dimensiones Ancho Altura Profundidad
H-1200 33 cm 55.8 cm 12.7 cm
NOTA:
El cabezal y el cartucho deben montarse en posición
vertical, con el cartucho colgando hacia abajo.Monte el cabezal
del ltro debajo del fregadero
3. MONTE EL CABEZAL DEL FILTRO DEBAJO DEL FREGADERO
A. Identique el cabezal de ltro doble y la válvula de cierre
(EV309860).
B. Aplique cinta de Fontanero a la rosca del lado de entrada
(izquierdo) del cabezal. Atornille la nueva válvula de
cierre y ajuste a mano. Repita lo mismo con el acoplador
inoxidable (EV312350) para el lado de salida (derecho) del
cabezal.
C. Aplique cinta de Fontanero a la rosca del codo adaptador
de salida (banda negra). Atornille dentro de la salida del
acoplador inoxidable. Enrolle la cinta en el sentido de las
roscas para asegurar un ajuste rme y evitar las pérdidas
pequeñas.
D. Monte rmemente el cabezal del ltro a la pared de
armarios usando los tornillos de montaje y las arandelas
incluidas.
4. Vaya a la página 15 y siga los pasos 4, 5 y 6 de las Instrucciones
Básicas de Instalación para completar la instalación del
Sistema H-1200.
DECLARACIONES Y NOTAS
Esta instalación debe cumplir con todas las leyes y reglamentos
locales y estatales.
No lo utilice con agua que sea microbiológicamente peligrosa
o de calidad desconocida sin usar una desinfección adecuada,
antes o después del sistema. Los sistemas certicados para la
reducción de quistes pueden usarse en aguas desinfectadas que
pudieran contener quistes ltrables.
Las pruebas se realizaron en condiciones normales de
laboratorio, el rendimiento real pudiera variar.
EPA Est. No. 002623-IL-002
3A
D
Dual Filter Head Shut Off Valve
C
B
2
55.8 cm
El H-54, H-300, H-104, H-300-HSD y H-1200 son
probados y certicados por NSF International contra
CSA B483.1 y NSF / ANSI 42 y 53 para las armaciones
especicadas en los Datos de rendimiento Hoja.
El H-300-NXT ha sido probado y certicado por NSF
International contra CSA B483.1 y NSF / ANSI 42, 53 y
401 para las armaciones especicadas en la Hoja de
datos de rendimiento de rendimiento.
C US
C US
El H-1200 está certicado por IAPMO R&T contra NSF/
ANSI 53 para la reducción de ácido peruorooctanoico
(PFOA) y sulfonato de peruorooctano (PFOS).
ESPAÑOL
EVERPURE Sistema De Filtración De Agua De La Serie H 19
ESPAÑOL
20EVERPURE Sistema De Filtración De Agua De La Serie H
EVERPURE
CARTUCHO H54  PIEZA N. EV973006, EV925268,
EV925266, EV925267
AVISO IMPORTANTE: Lea esta Hoja de información sobre
rendimiento y compare las capacidades de este sistema con
sus necesidades reales de tratamiento de agua. Se recomienda
que antes de adquirir una unidad de tratamiento de agua, haga
analizar su agua para determinar sus necesidades reales de
tratamiento del agua.
CARACTERÍSTICAS
Limpia adecuadamente el agua tratada y la convierte en agua
de calidad superior para beber o cocinar.
Reduce el gusto y el olor del cloro.
Reduce la suciedad, el óxido y otros materiales en partículas
como hierro oxidado, manganeso y sulfuros.
Con certificado de la Norma 53 de NSF/ANSI para reducir los
quistes como Cryptosporidium y Giardia por
medios mecánicos.
Adsorbe los sabores y olores frecuentes a tierra, moho y
pescado.
Reduce el nivel de plomo incluso por debajo de lo que marca el
Nivel de recomendación federal (Federal Action Level)
de 10 ppb.
Reduce las partículas pequeñas, hasta de 0.5 micrones
por medios mecánicos.
DATOS DE RENDIMIENTO DEL H-54
Este sistema ha sido analizado de acuerdo con las Normas
NSF/ ANSI 42 y 53 en cuanto a la reducción de las sustancias
enumeradas a continuación. La concentración de las sustancias
indicadas en el agua que entra al sistema se redujo a una
concentración menor o igual a los límites permitidos para el
agua que sale del sistema, como lo especifican las Normas
NSF/ANSI 42 y 53.
ESPECIFICACIONES DE FUNCIONAMIENTO
• Capacidad: 750 galones (2.839 litros)
• Requisito de presión: 10-125 psi (0.7 - 8.6 bar), sin choque
• Temperatura: 35-100°F (2°-38°C)
• Caudal: 0.5 gpm (1.9 Lpm)
SISTEMA DE AGUA POTABLE H54
REQUISITOS GENERALES DE INSTALACIÓN,
FUNCIONAMIENTO Y MANTENIMIENTO
Espacio requerido: 5 x 5 x 15 pulg. (13 x 13 x 38 cm) incluyendo
2-½ pulgadas de espacio libre debajo de la unidad para el cambio
de cartucho.
Instale verticalmente con el cartucho suspendido hacia abajo.
Use el largo mínimo posible de tubería.
Lave el nuevo cartucho a caudal pleno durante tres minutos para
purgar el aire.
Reemplace los cartuchos cuando alcancen su capacidad, o cuando
el flujo baje demasiado, pero al menos cada año.
AVISOS ESPECIALES
Las instrucciones de instalación, la disponibilidad de piezas y
servicio, y la garantía estándar se incluyen con el producto
cuando se envía.
Este sistema de agua potable se debe mantener según las
instrucciones del fabricante, incluyendo el reemplazo de los
cartuchos de filtro. Precio de lista sugerido: $100.99.
No se debe utilizar con agua microbiológicamente insegura o de
calidad desconocida sin la desinfección adecuada previa o
posterior al paso por el sistema. Los sistemas certificados para
la reducción de quistes pueden usarse en aguas desinfectadas
que pudieran contener quistes filtrables
Todas las sustancias contaminantes que este sistema de
tratamiento de agua elimina o reduce, no están necesariamente
presentes en el agua que usted consume.
Verifique el cumplimiento con las leyes y normas estatales y
locales aplicables.
Se probó en condiciones estándar de laboratorio; el rendimiento
en condiciones reales puede variar.
El medio de adsorción agotado no se regenerará y usará.
Si el medio de adsorción es afectado por el cloro, el suministro
de agua se deberá tratar para eliminar el cloro antes de ingresar
al filtro.
ESPAÑOL
20EVERPURE Sistema De Filtración De Agua De La Serie H
AVISO IMPORTANTE: Lea esta Hoja de información sobre
rendimiento y compare las capacidades de este sistema con sus
necesidades reales de tratamiento de agua. Se recomienda que
antes de adquirir una unidad de tratamiento de agua, haga analizar
su agua para determinar sus necesidades reales de tratamiento del
agua.
CARACTERÍSTICAS
Limpia adecuadamente el agua tratada y la convierte en agua de
calidad superior para beber o cocinar.
Reduce el gusto y el olor del cloro.
Reduce la suciedad, el óxido y otros materiales en partículas como
hierro oxidado, manganeso y sulfuros.
Con certicado de la Norma 53 de NSF/ANSI para reducir los quistes
como Cryptosporidium y Giardia por medios mecánicos.
Adsorbe los sabores y olores frecuentes a tierra, moho y pescado.
Reduce el nivel de plomo incluso por debajo de lo que marca el Nivel
de recomendación federal (Federal Action Level) de 10 ppb.
Reduce las partículas pequeñas, hasta de 0.5 micrones por medios
mecánicos.
H-54
Este sistema ha sido analizado de acuerdo con las Normas NSF/
ANSI
53 en cuanto a la reducción de las sustancias
enumeradas a continuación. La concentración de las sustancias
indicadas en el agua que entra al sistema se redujo a una
concentración menor
Sustancia
Concentración de
contaminantes en el
agua prefiltrada
Concentración máx.
permitida de productos en
el agua
Necesidad de
reducción
Reducción
mínima
Reducción
promedio
Estándar 42, efectos estéticos
Cloro 2.0 mg/L ± 10% ≥50% 86.8%
Partículas
clase I 0.5 a
<1 µm
al menos
10,000 partículas/ml ≥ 85% 98.8%
Estándar 53, efectos en la salud
Quistes Mínimo 50,000/L 99.95% 99.99% 99.99%
Plomo 8.5 0.15 mg/L ± 10% 0.010 mg/L 98.7% 99.3%
Plomo 6.5 0.15 mg/L ± 10% 0.010 mg/L 99.3% 99.3%
*Analizado en un caudal de servicio = 0.5 gpm, presión = 60 psig, pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
ESPECIFICACIONES DE FUNCIONAMIENTO
Capacidad: 750 galones (2.839 litros)
Requisito de presión: 10-125 psi (0.7 - 8.6 bar), sin choque
Temperatura: 35-100°F (2°-38°C)
Caudal: 0.5 gpm (1.9 Lpm)
EPA Est. 002623-IL-002
REQUISITOS GENERALES DE INSTALACIÓN, FUNCIONAMIENTO
Y MANTENIMIENTO
Espacio requerido: 5 x 5 x 15 pulg. (13 x 13 x 38 cm) incluyendo 2-½
pulgadas de espacio libre debajo de la unidad par a el cambio de
cartucho.
Instale verticalment e con el cartucho suspendido hacia abajo.
Use el largo mínimo posible de tubería.
Lave el nuevo cartucho a caudal pl eno durante tres minutos para
purgar el aire.
Reemplace los cartuchos cuando alc ancen su capacidad, o cuando
el ujo baje demasiado, pero al menos cada año.
AVISOS ESPECIALES
Las instrucciones de instalación, la disponibilidad de piezas y
servicio, y la garantía estándar se incluyen con el pr oducto cuando
se envía.
Este sistema de agua potabl e se debe mantener según las
instrucciones del fabricante, incluyendo el reemplazo de los
cartuchos de ltro. Precio de lista sugerido: $100.99.
No se debe utilizar con agua microbiológicamente insegur a o de
calidad desconocida sin la desinfección adecuada previa o posterior
al paso por el sistema. Los sistemas certicados para la reducción
de quistes pueden usarse en aguas desinfectadas que pudieran
contener quistes ltrables.
Todas las sustancias contaminant es que este sistema de
tratamiento de agua elimina o reduce, no están necesariamente
presentes en el agua que usted consume.
Verique el cumplimiento con las ley es y normas estatales y locales
aplicables.
Se probó en condiciones estándar de laborat orio; el rendimiento en
condiciones reales puede variar.
El medio de adsorción agotado no se regenerará y usar á.
Si el medio de adsorción es afectado por el cloro, el suminis tro de
agua se deberá tratar para eliminar el cloro antes de ingresar al
ltro.
Cartucho H-54 - Pieza n.° EV9730-06, EV9252-68, EV9252-66, EV9252-67
El sistema está probado y certicado por NSF
International bajo las normas CSA B483.1 y NSF/ANSI
53 en cuanto a las armaciones especicadas en la
Hoja de datos sobre rendimiento.
C US
HOJA DE INFORMACIÓN SOBRE RENDIMIENTO
EVERPURE
H-104 Cartridge - Part No. EV9612-11, EV9612-16
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
dna gniknird rof yt i lauq muimerp ot retaw detaert sehsi lop yleniF
cooking.
Reduces chlorine taste and odor.
, nor i dez i d i xo sa hcus se t a l uc i t rap reht o dna t sur , t r i d secudeR
manganese, and sulfides.
NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Reduces common earthy, moldy, fishy tastes and odors.
Reduces lead to below the Federal Action Level.
Reduces particles as small as 0.5 micron in size by mechanical
means.
H-104 PERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ° 50% 87.8%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL ° 85% 98.8%
Standard 53—Health Effects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.010 mg/L 99.3% 99.3%
Lead 6.5 0.15 mg/L ± 10% 0.010 mg/L 98.7% 99.3%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
OPERATING SPECIFICATIONS
Capacity: 1,000 gallons (3,780L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2°-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
EPA Est. 002623-IL-002
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
gnidulcni )mc 15 x 31 x 31( .ni 02 x 5 x 5 :deriuqer ecapS
2½ inches of clear space under unit for cartridge change.
Install vertically with cartridge hanging down.
Use minimum length of tubing possible.
Flush new cartridge at full flow for three minutes to purge air.
semoceb wo l f nehw r o , dehcae r s i y t i capac nehw segd i r t r ac eca l peR
too slow, but at least annually.
SPECIAL NOTICES
Installation instructions, parts and service availability, and standard
warranty are included with the product.
This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges. Suggested retail $122.99.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
The contaminants or other substances removed or reduced by this
water treatment system are not necessarily in your water.
Check for compliance with state and local laws and regulations.
Tested under standard laboratory conditions, actual performance
may vary.
Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
System Tested and Certified by NSF International against
CSA B483.1 and NSF/ANSI 42 and 53 for the claims
specified on the Performance Data Sheet.
H-104 DRINKING WATER SYSTEMS
C US
PERFORMANCE DATA SHEET
El sistema está probado y certificado por NSF
International bajo las normas CSA B483.1 y
NSF/ANSI 42 y 53 en cuanto a las afirmaciones
especificadas en la Hoja de datos sobre
rendimiento.
EPA Est. No. 002623-IL-002
HOJA DE INFORMACIÓN SOBRE RENDIMIENTO
20EVERPURE Sistema De Filtración De Agua De La Serie H
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Pentair H SERIES Water Filtration Systems Manuel utilisateur

Catégorie
Filtres à eau
Taper
Manuel utilisateur