Disconnect the Power
Power to the dimmer and load can be disconnected by using the air-gap
switch, which is located at the bottom of the device. Slide the air-gap switch to
the right to disconnect the power to the device and to the load, and slide the
switch to the left to restore power to both the device and the load.
NOTE: The switch must be in the left position for the device to operate.
Slide the air-gap switch to the
right to shut off power to the
unit and the load.
Default Button Functionality
The figure below illustrates the press and hold actuation sequences for each
local button option (selected in programming) when the Local button is
enabled. There is only one local button available per device.
If the Local button is disabled and control system communication is lost, the
device will default to the shown behavior for the local button. Button behavior
can be altered by the control system program. With the Local button enabled,
the selected local button can still act as a remote trigger. However, LED
feedback for the selected local button will be dictated only by the local load.
C
A
B
B
B
B
B
A
A
A
A
Button
Single Press Double Press Hold
A
On Fast On Raise
B
Off Fast Off Lower
C
Toggle N/A Raise/Lower
NOTES:
• The default “On” powers the load to 100% in 1 second. The default
“Fast On” powers the load to 100% in 1/4 second. Load behavior for
“On” and “Fast On” operations can be modified when programming the
HZ-DIMEX .
• The single push button or side-to-to-side rocker can be designated as
the local button in any of the five available positions.
LED Behavior
The LEDs on the HZ-DIMEX display the state of the connected loads and are
located under each button cap.
Each LED can be in one of the following states:
NOTE: LED functionality for both local and remote behavior can be modified
when programming the device.
• On: The load is powered.
• Off: The load is not powered.
• Flashing: The load is ramping up or down.
Multiway Operation
For more information on multiway operation, refer to the HZ-AUX Quick Start
(Doc. 8485) or the HZ-KPEX Quick Start (Doc. 8284).
Wireless Communications
The device connects to the Crestron network via the infiNET EX
communications protocol. Use the following procedures to join or leave an
infiNET EX network and to verify communications between the device and the
control system.
NOTE: The HZ-DIMEX is not compatible with the MC3 internal gateway when
using channels 25 or 26.
Joining an infiNET EX Network
Before a device can be used in a lighting system, it must first join an infiNET EX
network by being acquired by an infiNET EX gateway.
NOTE: A device can be acquired by only one gateway.
1. Put the infiNET EX gateway into Acquire mode from the unit itself or
from Crestron Toolbox software, as described in the gateway’s manual
at www.crestron.com/manuals.
NOTE: In an environment where multiple gateways are installed, only
one gateway should be in Acquire mode at any time.
2. Place the device into Acquire mode.
a. Tap the top button three times, and then press and hold it down
(tap-tap-tap-press+hold) until all of the LEDs flash red once (this
can take up to 10 seconds).
NOTE: If a side -to-side rocker is in the top position, either side of the
rocker can be pressed and held.
b. Release the button to start the acquire process. The top button’s
LED flashes red slowly to show that the device is actively scanning
the infiNET EX network.
• The top button’s LED lights red for 5 seconds to show that the
device has been successfully acquired to the infiNET EX network.
• The top button’s LED flashes red quickly to indicate that the
device was not successfully acquired by the infiNET EX network.
Tap the setup button to acknowledge failure to acquire the
infiNET EX network. Ensure the gateway is in Acquire mode and
within range before attempting the acquire process again.
3. Once all devices have been acquired, take the gateway out of Acquire
mode. Refer to the gateway’s manual for details.
Leaving an infiNET EX Network
To leave an infiNET EX network, put the device into Acquire mode, as described
in “Joining an infiNET EX Network” above, when no gateway is in Acquire
mode.
Verifying Communications Status
To check the communications status of the device, tap the top button three
times and then press and hold it down (tap-tap-tap-press+hold) for up to 2
seconds. The button must be released before the LEDs flash to indicate the
communications status. Refer to the following table for details.
NOTES:
• If a side -to-side rocker is in the top position, either side of the rocker can
be pressed and held.
• If there is a communication error and a remote button is pressed, all
of the LEDs will flash red in one of the patterns described in the table
below.
LED Communications Status
Turns on for 5
seconds
The device is communicating with the control system.
Flashes three
times
The device is communicating with the gateway, but the
gateway is not communicating with the control system.
Flashes twice The device was previously joined to the network but is not
communicating with the gateway.
Flashes once The device is not joined to the network.
Ambient Light Sensor Calibration
An LED backlight behind each button illuminates engravings. The ambient
light sensor adjusts the backlight brightness according to the light level in the
room. The ambient light sensor can be affected by room conditions and should
be calibrated manually (locally or through programming), or the appropriate
setting can be changed in control system programming.
To locally calibrate the light sensor:
1. Ensure that all room lights are fully on.
2. Ensure the faceplate and bottom trim piece are installed correctly.
Remove the top trim piece.
3. Press and hold the setup button with a small pointed object until all
keypad backlights flash magenta (about 2 seconds). This can also be
triggered in programming.
4. Avoid blocking the light sensor on the bottom of the HZ-DIMEX. The
light sensor should remain unobstructed and free of direct light. After
about 5 seconds, the calibration process is complete. The keypad returns
to normal operation.
Setup
button
Backlight Customization
Backlight color customization can be accomplished locally or through
programming.
NOTE: Custom and preset color themes may be defined in the control system
program. Custom programming will override local settings.
To locally change the color of the LED backlights:
1. Press the setup button with a small pointed object once. The LED
backlights will light brightly for 15 seconds.
2. Press the setup button repeatedly to cycle through the backlight color
options.
Troubleshooting
The module displays error codes using the dimmer output LEDs. The LED
flashes a pattern to indicate the error on that output. For example, a 1-2 error
flashes the LED one time, pauses for 1 second, flashes two times, pauses for
2 seconds, and then repeats for 90 seconds (except where otherwise noted).
Refer to the following table for possible corrections.
Error
Code
Fault Name Fault Description
2-3 Over
Temperature
The dimmer has overheated and shut down due to
an excessive load. Verify that the total load matches
the proper ganged rating. The dimmer resumes
normal operation after cooling.
3-1 Zero Cross
Fault
The dimmer is unable to lock onto the AC line. If
the unit is powered by a generator, verify that the
generator output is 50/60 Hz and stable.
3-3 Device Error The device is experiencing a hardware issue. Please
contact Crestron Technical Support.
For general troubleshooting, please refer to the following table:
Trouble Probable Cause(s) Corrective Action
The
dimmer
does not
function.
The dimmer is not
receiving power.
Verify that the power connections are
correct and that the circuit breaker
is closed.
The load is not
operational (e.g. lamps
are burned out).
Verify that the load is operational and
that the airgap switch is closed.
The device is in Remote
mode.
Check the program to verify the
operating mode.
The air-gap is switched
to the right.
Ensure that the air-gap is switched
to the left.
The device has
overheated.
Verify that the device is loaded
properly for ganged configuration.
The neutral wire is
not connected to the
dimmer.
Connect a dedicated neutral wire to
the dimmer.
The
dimmer
does not
dim.
The device is in
Non-Dim mode.
Remove power from the device.
Reapply power and press and hold the
bottom button until all LEDs flash
green once.
Additional Information
Scan or click the QR code for detailed product information.
HZ-DIMEX
Compliance and Legal
Original Instructions: The U.S. English version of this document is the original instructions. All
other languages are a translation of the original instructions.
Regulatory Model: M201849003
Federal Communications Commission (FCC) Compliance Statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures: Reorient or relocate the
receiving antenna; Increase the separation between the equipment and receiver; Connect the
equipment into an outlet on a circuit different from that to which the receiver is connected;
Consult the dealer or an experienced radio/TV technician for help.
To satisfy FCC RF Exposure requirements for mobile and base station transmission devices,
a separation distance of 20 cm or more should be maintained between the antenna of this
device and persons during operation. To ensure compliance, operation at closer than this
distance is not recommended. The antenna(s) used for this transmitter must not be co-
located or operating in conjunction with any other antenna or transmitter
CAUTION: Changes or modications not expressly approved by the manufacturer responsible
for compliance could void the user’s authority to operate the equipment.
Industry Canada (IC) Compliance Statement
CAN-ICES-3(B)/nmb-3 (B)
This device complies with Industry Canada license exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1)
l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le
fonctionnement.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna
of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada.
To reduce potential radio interference to other users, the antenna type and its gain should
be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut
fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé
pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain
de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne
dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante
Intertek Compliance Statement
This product is listed to applicable UL Standards and requirements tested by Intertek services.
Ce produit est homologue selon les normes et les exigences UL applicables par Intertek
Prestations de service.
The product warranty can be found at www.crestron.com/warranty.
The specific patents that cover Crestron products are listed at
www.crestron.com/legal/patents.
Certain Crestron products contain open source software. For specific information, please
visit www.crestron.com/opensource.
Crestron, the Crestron logo, Crestron Home, Crestron Toolbox, Horizon, infiNET EX, and the
infiNET EX logo are either trademarks or registered trademarks of Crestron Electronics, Inc.
in the United States and/or other countries. Other trademarks, registered trademarks, and
trade names may be used in this document to refer to either the entities claiming the marks
and names or their products. Crestron disclaims any proprietary interest in the marks and
names of others. Crestron is not responsible for errors in typography or photography.
©2019 Crestron Electronics, Inc.
Crestron Electronics, Inc.
15 Volvo Drive, Rockleigh, NJ 07647
Tel: 888.CRESTRON
Fax: 201.767.7576
www.crestron.com
Quick Start - Doc. 8289A
(2054064)
09/26/19
Specifications subject to
change without notice.