Inovelli NZW31 Manuel utilisateur

Catégorie
Gradateurs
Taper
Manuel utilisateur
Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may caus harmful interference to radio communications.However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.Increase the separation between the equipment and
receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.Consult the dealer or an experienced radio/TV technician for help.This equipment
should be installed and operated with minimum distance 20cm between the radiator and your body.
IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired
operation of the device.
DECLARATION DE CONFORMITE D'INDUSTRIE CANADA
Ce périphérique a été testé et reconnu conforme aux limites spécifiées dans RSS-210.
Son utilisation est soumise aux deux conditions suivantes :
(1) il ne doit pas provoquer d'interférences gênantes et
(2) il doit tolérer les interférences re.ues, notamment cellessusceptibles d'en perturber le fonctionnement.
NZW31 Smart Dimmer Manual
Smart Dimmer
(2) il doit tolérer les interférences re.ues, notamment cellessusceptibles d'en perturber le fonctionnement.
WARRANTY
Show Home Products warrants this product to be free from manufacturing defects for
a period of two years from the original date of consumer purchase. This warranty is limited
to the repair or replacement of this product only and does not extend to consequential or
incidental damage to other products that may be used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some states do not
allow limitations on how long an implied warranty lasts or permit the exclusion or limitation
of incidental or consequential damage, so the above limitations may not apply to you.
state to state. if the unit should prove defective within the warranty period.
SPECIFICATIONS WARNING
RISK OF FIRE
Model:NZW31
RISK OF ELECTRICAL SHOCK
Power: 120 VAC, 60 Hz.
RISK OF BURNS
Signal (Frequency): 908.42 MHZ.
CONTROLLING APPLIANCES:
Dimension(L*W*H):115*71*42(mm)
EXERCISE EXTREME CAUTION WHEN USING Z-WAVE DEVICES TO CONTROL
Maximum Loads: 500W, 2-gang 400W or 3-gang
APPLIANCES. OPERATION OF THE Z-WAVE DEVICE MAY BE IN A DIFFERENT
300W incandescent, 150W CFL/LED
ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION
Range: Up to 100 feet line of sight between the
MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-WAVE DEVICES
Wireless Controller and the closest Z-Wave
MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING.
receiver module.
DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL
Operating Temperature Range: 32-104° F (0-40° C)
OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE
For indoor use only.
REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
Specifications subject to change without notice
THE FOLLOWING:
due to continuing product improvement
DO NOT USE Z-WAVE DEVICES TO CONTROL ELECTRIC HEATERS OR ANY OTHER
IMPORTANT!
APPLIANCES WHICH MAY PRESENT A HAZARDOUS CONDITION DUE TO UNATTENDED OR
The fixture controlled by the Z-Wave In-wall Smart
UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.
Dimmer must not exceed 600 watts (Incandescent);
150W dimmable CFL/LED. The Dimmer is
designed only for use with permanently installed fixtures.
Website:www.ishowlights.com
1. Getting To Know Your New Z-Wave Device
• Dimming light manually or remotely via the Z-Wave controller
• Can be Included in multiple Groups and Scenes
• Compatible with all incandescent and CFL/ LED bulbs
• Blue LED indicates switch location in a dark room
• Z-Wave Certified for simple pairing and integrated home automation
• Screw Terminal Installation — requires wiring connections for Line (Hot), Load, Neutral.
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the dimmer and lighting fixture at the service panel. All wiring
connections must be made with the power OFF to avoid personal injury and/or damage to the switch.
A. Up Push button
B. Down Push button
C. Load (Black)
D. Line (Black) - Line in
E. Neutral (White) - Neutral in
Single switch wiring
1. Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to switch box before continuing.
2. Remove wall plate.
3. Remove the dimmer mounting screws.
4. There are up to three screw terminals on the dimmer; these are marked
C. Load — Black (connected to lighting)
D. Line — Black (connected to power)
E. Neutral — White (Neutral)
5. Observe Important Wiring Information
IMPORTANT!: This dimmer is rated for and intended to only be used with copper wire. Wire Gauge Requirements
Use larger wires suitable for at least 80° C for supplying Line (HOT), Load, Neutral connections.
Wire strip length:
For attachment to screw terminals: Strip insulation 1" , For attachment using the enclosure’s holes: Strip
insulation 5/8".
6. Connect the black wire that goes to the light to the terminal marked Load.
7. Connect the black wire that comes from the electrical service panel (Hot) to the terminal marked Lin.
8. Connect the white wire to the neutral terminal marked Nin (use jumper wire if needed).
9. Insert dimmer into the switch box being careful not to pinch or crush wires.
10. Secure the dimmer to the box using the supplied screws.
11. Mount the wall plate.
12. Reapply power to the circuit at fuse box or circuit breaker and test the system.
Basic Operation
The connected light can be dimming in two ways,
1. Manually from the front button of the In-wall dimmer
2. Remotely with a Z-Wave Controller
Manual Control
The Front button allows the user to:
dim the connected fixture.
To dimming the connected light bright: Press the Up push button.
To dimming the connected light dark: Press the Down push button.
2. Linking your Z-Wave device
Reset your dimmer to factory default:
Please use your controller to remove the device from the network. To factory reset, toggle UP the switch 10x in a row when
powered on. However, please only use this method if your controller is missing or inoperable.
Adding device into the network:
1. Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network.
2. Once the controller is ready to include your device, press the UP button 6x to include it
in the network.
3. OOnnccee yyoouurr ccoonnttrroolllleerr hhaass ccoonnffiirrmmeedd tthhaatt tthhee ddeevviiccee hhaass bbeeeenn iinncclluuddeedd,, rreeffrreesshh tthhee ZZ--WWaavvee nneettwwoorrkk ttoo optimize
performance.
4. The device is associated in the same group when it included in setting process. Now you can control your
Z-Wave device according to groups, scenes, schedules and automation programmed. If your controller
features remote access, you can now control all devices in Z-Wave network from mobile devices.
To exclude the device
1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network.
2. Once the controller is ready to Exclude your device, triple press the Up/Down push button to exclude it
from the network.
Note
: Your controller may need to be within 10 feet of the device to be included.
All non-battery nodes within Z-Wave network will act as repeater.
The association group supports five nodes and lifeline function.
Scene control is only available to HUB/Gateway's that support Z-Wave's Central Scene Command
Package content
In-wall Smart Dimmer-1pcs
Screw-2 pcs
Installation Operation manual-1pcs
  • Page 1 1
  • Page 2 2
  • Page 3 3

Inovelli NZW31 Manuel utilisateur

Catégorie
Gradateurs
Taper
Manuel utilisateur

dans d''autres langues